FORM_RESPONSE_ID|SCHOOL_DISTRICT|BEDS_CODE|BUILDING_NAME|BLDG_ID|SURVEY_INSPECT_DATE|BLDG_911_ADDRESSS|CITY|ZIP|CERT_OCCUPANCY_STATUS|CERT_EXPIRE_DATE|YEAR_OF_ORIG_BLDG|BLDG_GROSS_SQ_FT|NUM_OF_FLOORS|FT_CUSTODIANS|PT_CUSTODIANS|BLDG_OWNERSHIP|CUR_PURP_OF_BLDG_USE|CUR_PURP_BLDG_USE_CMNT|CURYR_NUMSTDNTS_INBLDG_INSTRCT|GRADES_HOUSED|CURRENT_YR_INSTRUCTIONAL_DAYS|BLDG_USED_SUMMER_FOR_INSTRUC|RENOVATIONS_PAST_12_MONTHS|PERMANENT_INSTRUCT_SPACES|TEMP_INSTRUCT_SPACES|NON_TRAD_INSTRUC_SPACES|TYPE_NONINSTRUCT_USED_INSTRUCT|TYPE_NONINSTRUCT_USED_CMNT|NUM_INSTRUCT_SPACES|GROSS_SQ_FT_ALL_INSTRUCT_SPACE|OTHER_SPACES|OTHER_SPACES_CMNT|HAS_FUEL_OIL_TANKS|NUM_ABV_GRD_FUEL_TANKS|CAPACITY_ABV_GRD_FUEL_TANKS|NUM_BLW_GRD_FUEL_TANKS|CAPACITY_BLW_GRD_FUEL_TANKS|CONDIT_FUEL_TANKS|TANKS_LST_YR_MJR_RECONS_REPLAC|TANKS_REMAIN_YRS|TANKS_COST_RECONSTRUCT_REPLACE|FUEL_TANKS_COMMENTS|HAS_WATER_SERVICE|TYPE_WATER_SERVICE|CONDIT_WATER_SERVICE|H2OSVC_LSTYR_MJRRECONS_REPLAC|H2OSERVICE_REMAIN_YRS|H2OSVC_COST_RECONSTRUCT_REPLAC|H2OSVC_COMMENTS|HAS_SITE_SANITARY|TYPE_SITESAN|CONDIT_SITESAN|SITESAN_LSTYR_MJRRECONS_REPLAC|SITESAN_REMAIN_YRS|SITESAN_COSTRECONSTRUCT_REPLAC|SITESAN_COMMENTS|HAS_GAS_SVC|CONDIT_GAS_SVC|GAS_SVC_LSTYR_MJRRECONS_REPLAC|GAS_SVC_REMAIN_YRS|GAS_SVC_COSTRECONSTRUCT_REPLAC|GAS_SVC_COMMENTS|HAS_ELECTRICAL|ELECTRICAL_SVC_PROVIDER|TYPE_ELECTRICAL|CONDIT_ELECTRICAL|ELECTR_LSTYR_MJRRECONS_REPLAC|ELECTRICAL_REMAIN_YRS|ELECTR_COSTRECONSTRUCT_REPLAC|ELECTRICAL_COMMENTS|HAS_CLOSED_PIPE_SYS|CONDIT_CLOSED_PIPE_SYS|PIPE_LSTYR_MJRRECONS_REPLAC|PIPE_SYS_REMAIN_YRS|PIPESYS_COSTRECONSTRUCT_REPLAC|PIPE_SYS_COMMENTS|HAS_OPEN_STORM_SYS|STORMSYS_CONDIT|STRMSYS_LSTYR_MJRRECONS_REPLAC|STORMSYS_REMAIN_YRS|STORMSYS_CSTRECONSTRUCT_REPLAC|STORMSYS_COMMENTS|HAS_CATCHBASINS_MANHOLES|CONDIT_BASINS|BASINS_LSTYR_MJRRECONS_REPLAC|BASINS_REMAIN_YRS|BASINS_COSTRECONSTRUCT_REPLAC|BASINS_COMMENTS|HAS_CULVERTS|CULVERTS_CONDIT_CULVERTS|CULVRTS_LSTYR_MJRRECONS_REPLAC|CULVERTS_REMAIN_YRS|CULVRTS_COSTRECONSTRUCT_REPLAC|CULVERTS_COMMENTS|HAS_OUTFALLS|PT_OF_OUTFALL_DISCHARGE|PT_OF_OUTFALL_DISCHARGE_CMNT|OUTFALLS_INSPECTED|CONDIT_OUTFALLS|OUTFLLS_LSTYR_MJRRECONS_REPLAC|OUTFALLS_REMAIN_YRS|OUTFALLS_CSTRECONSTRUCT_REPLAC|OUTFALLS_COMMENTS|HAS_INFILTRAT_BASINS_CHAMBERS|CONDIT_CHAMBERS|CHMBRS_LSTYR_MJRRECONS_REPLAC|CHAMBERS_REMAIN_YRS|CHMBRS_CSTRECONSTRUCT_REPLAC|CHAMBERS_COMMENTS|HAS_RETENTITON_BASINS|RETENTBASIN_CONDIT|RETBSN_LSTYR_MJRRECONS_REPLAC|RETBSN_REMAIN_YRS|RETBSN_CSTRECONSTRUCT_REPLAC|RETBSN_COMMENTS|HAS_WETPONDS|WETPONDS_CONDIT|WTPND_LSTYR_MJRRECONS_REPLAC|WETPONDS_REMAIN_YRS|WTPOND_CSTRECONSTRUCT_REPLAC|WETPONDS_COMMENTS|HAS_PROPRIETARY_UNITS|PROPUNITS_CONDIT|PROPUNT_LSTYR_MJRRECONS_REPLAC|PROPUNITS_REMAIN_YRS|PROPUNT_CSTRECONSTRUCT_REPLAC|PROPUNITS_COMMENTS|HAS_PAVEMENT|PAVEMENT_TYPE|PAVEMENT_CONDIT|PVMT_LSTYR_MJRRECONS_REPLAC|PVMT_REMAIN_YRS|PVMT_CSTRECONSTRUCT_REPLAC|PVMT_COMMENTS|HAS_SIDEWALKS|SIDEWALK_TYPE|SIDEWALK_CONDIT|SIWLK_LSTYR_MJRRECONS_REPLAC|SIDEWALK_REMAIN_YRS|SIWLK_CSTRECONSTRUCT_REPLAC|SIDEWALK_COMMENTS|HAS_PLAYGROUNDS|PLAYGROUND_CONDIT|PLYGRND_LSTYR_MJRRECONS_REPLAC|PLAYGROUND_REMAIN_YRS|PLYGRND_CSTRECONSTRUCT_REPLAC|PLAYGROUND_COMMENTS|HAS_ATHLETICFIELDS|ATHLETIC_CONDIT|ATHLTC_LSTYR_MJRRECONS_REPLAC|ATHLETIC_REMAIN_YRS|ATHLTC_CSTRECONSTRUCT_REPLAC|SYNTHTIC_TURF_PRESENT|ATHLETIC_COMMENTS|FOUNDATION_TYPE|FOUNDATION_CRACKS|FOUNDATION_HEAVING|FOUNDATION_DECAY|FOUNDATION_WATER_PENET|FOUNDATION_UNSUPPORTED|FOUNDATION_OTHER_CONCERNS|FOUNDATION_CONDIT|FNDATN_LSTYR_MJRRECONS_REPLAC|FOUNDATION_REMAIN_YRS|FNDATN_CSTRECONSTRUCT_REPLAC|FOUNDATION_COMMENTS|HAS_FIREWALLS|FIREWALLS_CONDIT|FIREWL_LSTYR_MJRRECONS_REPLAC|FIREWALLS_REMAIN_YRS|FIREWL_CSTRECONSTRUCT_REPLAC|FIREWALLS_COMMENTS|HAS_OTHER_INTERIOR_WALLS|OTHERINWALLS_CONDIT|OTHINWL_LSTYR_MJRRECONS_REPLAC|OTHERINWALLS_REMAIN_YRS|OTHINWLS_CSTRECONSTRUCT_REPLAC|OTHERINWALLS_COMMENTS|HAS_CEILING|CEILING_CONDIT|CELNG_LSTYR_MJRRECONS_REPLAC|CEILING_REMAIN_YRS|CELNG_CSTRECONSTRUCT_REPLAC|CEILING_COMMENTS|HAS_LOCKERS|LOCKER_CONDIT|LOCKER_LSTYR_MJRRECONS_REPLAC|LOCKER_REMAIN_YRS|LOCKER_CSTRECONSTRUCT_REPLAC|LOCKER_COMMENTS|HAS_INTERIOR_DOORS|INT_DOORS_UNIT_CONDIT|INT_DOORS_HDWR_CONDIT|INTDRS_LSTYR_MJRRECONS_REPLAC|INT_DOORS_REMAIN_YRS|INTDRS_CSTRECONSTRUCT_REPLAC|INT_DOORS_COMMENTS|HAS_INTERIOR_STAIRS|INT_STAIRS_CONDIT|INTSTR_LSTYR_MJRRECONS_REPLAC|INT_STAIRS_REMAIN_YRS|INTSTR_CSTRECONSTRUCT_REPLAC|INT_STAIRS_COMMENTS|HAS_ELEVATORS_ESCALATORS|ELEVATORS_CONDIT|ELVTR_LSTYR_MJRRECONS_REPLAC|ELEVATORS_REMAIN_YRS|ELVTR_CSTRECONSTRUCT_REPLAC|ELEVATORS_COMMENTS|HAS_INTERIOR_ELECTRICAL|INT_ELECTR_MEETS_NEEDS|INT_ELECTR_CONDIT|INELCTR_LSTYR_MJRRECONS_REPLAC|INT_ELECTR_REMAIN_YRS|INTELCTR_CSTRECONSTRUCT_REPLAC|INT_ELECTR_COMMENTS|HAS_LIGHTING_FIXTURES|LIGHTING_FIXT_CONDIT|LTFIXT_LSTYR_MJRRECONS_REPLAC|LIGHTING_FIXT_REMAIN_YRS|LTFIXT_CSTRECONSTRUCT_REPLAC|LIGHTING_FIXT_COMMENTS|HAS_COMMUNICATION_SYSTEMS|COM_SYS_ADEQUATE|COM_SYS_CONDIT|COMSYS_LSTYR_MJRRECONS_REPLAC|COM_SYS_REMAIN_YRS|COMSYS_CSTRECONSTRUCT_REPLAC|COM_SYS_COMMENTS|HAS_SWIMMING_POOL|SWIMMING_POOL_CONDIT|SWIMPL_LSTYR_MJRRECONS_REPLAC|SWIMMING_POOL_REMAIN_YRS|SWIMPL_CSTRECONSTRUCT_REPLAC|SWIMMING_POOL_COMMENTS|HAS_CARPET|CARPET_LOCATION|CARPET_CONDIT|CRPT_LSTYR_MJRRECONS_REPLAC|CARPET_REMAIN_YRS|CRPT_CSTRECONSTRUCT_REPLAC|CARPET_COMMENTS|HAS_TILES_SHEET_FLOORING|TILEFLOORING_LOCATION|TILEFLOOR_CONDIT|TILEFLR_LSTYR_MJRRECONS_REPLAC|TILEFLOOR_REMAIN_YRS|TILEFLR_CSTRECONSTRUCT_REPLAC|TILEFLOOR_COMMENTS|HAS_HARD_FLOORING|HARD_FLOORING_LOCATION|HARD_FLOOR_CONDIT|HARDFLR_LSTYR_MJRRECONS_REPLAC|HARD_FLOOR_REMAIN_YRS|HARDFLR_CSTRECONSTRUCT_REPLAC|HARD_FLOOR_COMMENTS|HAS_WOOD_FLOORING|WOOD_FLOOR_LOCATION|WOOD_FLOOR_CONDIT|WOODFLR_LSTYR_MJRRECONS_REPLAC|WOOD_FLOOR_REMAIN_YRS|WOODFLR_CSTRECONSTRUCT_REPLAC|WOOD_FLOOR_COMMENTS|STRUCTURAL_FLOOR_TYPE|STRUCTUR_FLR_TYPE_CMNT|FLOOR_SUPPORT_CRACKS|FLOOR_SUPPORT_UNSPPORTED|FLOOR_SUPPORT_ROT|FLOOR_SUPPORT_DEFLECTION|FLOOR_SUPPORT_SERIOUSDMG|FLOOR_SUPPORT_OTHERPROBS|FLOOR_DECK_CRACKS|FLOOR_DECK_DEFLECTION|FLOOR_DECK_ROT|FLOOR_CONDIT|STRCFLR_LSTYR_MJRRECONS_REPLAC|FLOOR_REMAIN_YRS|STRUCFLR_CSTRECONSTRUCT_REPLAC|FLOOR_COMMENTS|EXTERIORWALLS_MATERIAL|EXTWALLS_SUPPORT_CRACKS|EXTWALLS_SUPPORT_ROT|EXTWALLS_SUPPORT_OTHERPROBS|EXTWALLS_CLADDING_CRACKS|EXTWALLS_CLADDING_FLASHING|EXTWALLS_CLADDING_EFFLORES|EXTWALLS_CLADDING_MOISTPEN|EXTWALLS_CLADDING_ROT|EXTWALLS_CLADDING_OTHERPROBS|EXTWALLS_CONDIT|EXTWALL_LSTYR_MJRRECONS_REPLAC|EXTWALLS_REMAIN_YRS|EXTWALLS_CSTRECONSTRUCT_REPLAC|EXTWALLS_COMMENTS|HAS_CHIMNEY|CHIMNEY_TYPE|CHIMNEY_CONDIT|CHIMNEY_LSTYR_MJRRECONS_REPLAC|CHIMNEY_REMAIN_YRS|CHIMNEY_CSTRECONSTRUCT_REPLAC|CHIMNEY_COMMENTS|HAS_PARAPETS|PARAPET_TYPE|PARAPET_CONDIT|PARAPET_LSTYR_MJRRECONS_REPLAC|PARAPET_REMAIN_YRS|PARAPET_CSTRECONSTRUCT_REPLAC|PARAPET_COMMENTS|EXTERIOR_DOOR_UNIT_CONDITION|EXTERIOR_DOOR_HDWR_CONDITION|EXIT_DOORS_HAVE_MAGLOCKS|EXTDOORS_SECURITY_ADEQT|EXTDRS_LSTYR_MJRRECONS_REPLAC|EXTDOORS_REMAIN_YRS|EXTDOORS_CSTRECONSTRUCT_REPLAC|EXTDOORS_COMMENTS|HAS_EXTERIOR_STAIRS|EXTSTAIRS_CONDIT|EXTSTRS_LSTYR_MJRRECONS_REPLAC|EXTSTAIRS_REMAIN_YRS|EXTSTRS_CSTRECONSTRUCT_REPLAC|EXTSTAIRS_COMMENTS|HAS_FIRE_ESCAPES|FIRE_ESCAPES_CONDIT|FIRE_ESCAPES_SAFETY_ADEQ|FIREESC_LSTYR_MJRRECONS_REPLAC|FIRE_ESCAPES_REMAIN_YRS|FIREESC_CSTRECONSTRUCT_REPLAC|FIRE_ESCAPES_COMMENTS|HAS_WINDOWS|WINDOW_TYPES|WINDOW_CONDITION|WINDOWS_OPERABLE|WINDOW_LSTYR_MJRRECONS_REPLAC|WINDOW_REMAIN_YRS|WINDOW_CSTRECONSTRUCT_REPLAC|WINDOW_COMMENTS|ROOF_CONSTRUCT_TYPE|ROOF_MATERIAL_TYPE|ROOFSUPPORT_CRACKS|ROOFSUPPORT_UNSUPPORTED|ROOFSUPPORT_ROT|ROOFSUPPORT_DEFLECTION|ROOFSUPPORT_SERIOUSDMG|ROOFSUPPORT_OTHERPROBS|ROOFDECK_CRACKS|ROOFDECK_DECAY|ROOFDECK_ROT|ROOFING_CRACKS|ROOFING_ROT|ROOFING_INADEQFLASHING|ROOFING_INADEQDRAINS|ROOFING_LEAKS|ROOFING_OTHERPROBS|ROOF_CONDITION|ROOF_LSTYR_MJRRECONS_REPLAC|ROOF_REMAIN_YRS|ROOF_CSTRECONSTRUCT_REPLAC|ROOF_COMMENTS|HAS_SKYLIGHTS|SKYLIGHT_MATERIAL|SKYLIGHT_CONDITION|SKYLT_LSTYR_MJRRECONS_REPLAC|SKYLIGHT_REMAIN_YRS|SKYLT_CSTRECONSTRUCT_REPLAC|SKYLIGHT_COMMENTS|HAS_WATERDISTSYS|WATERDISTSYS_PIPE_TYPE|H2ODIST_CONDITION|H2ODIST_LSTYR_MJRRECONS_REPLAC|H2ODIST_REMAIN_YRS|H2ODIST_CSTRECONSTRUCT_REPLAC|H2ODIST_COMMENTS|HAS_PLUMBINGDRAINAGESYS|PLUMBDRAINAGEPIPE_TYPE|PDRAINAGE_CONDITION|PDRAING_LSTYR_MJRRECONS_REPLAC|PDRAINAGE_REMAIN_YRS|PDRAING_CSTRECONSTRUCT_REPLAC|PDRAINAGE_COMMENTS|HAS_HOTH20HEATERS|HOTH20FUEL_TYPE|HOTH20_CONDITION|HOTH20_LSTYR_MJRRECONS_REPLAC|HOTH20_REMAIN_YRS|HOTH20_CSTRECONSTRUCT_REPLAC|HOTH20_COMMENTS|HAS_PLUMBINGFIXTURES|PFIXTR_CONDITION|PFIXTR_LSTYR_MJRRECONS_REPLAC|PFIXTR_REMAIN_YRS|PFIXTR_CSTRECONSTRUCT_REPLAC|PFIXTR_COMMENTS|HAS_HVACSYS|HVACSYS_TECHNOLOGY|HAS_HEATGENSOURCE|HEATGENSOURCE_TYPE|HEATGENSOURCE_TYPE_CMNT|HEATGEN_CONDITION|HEATGEN_LSTYRMJRRECONSREPLAC|HEATGEN_REMAIN_YRS|HEATGEN_CSTRECONSTRUCTREPLAC|HEATGEN_COMMENTS|HAS_HEATINGFUELSYS|HFUELSYS_CONDITION|HFUELSYS_LSTYRMJRRECONSREPLAC|HFUELSYS_REMAIN_YRS|HFUELSYS_CSTRECONSTRUCTREPLAC|HFUELSYS_COMMENTS|HAS_ACSYSTEM|AC_CONDITION|AC_LSTYR_MJRRECONS_REPLAC|AC_REMAIN_YRS|AC_CSTRECONSTRUCT_REPLAC|AC_COMMENTS|HAS_VENTILATIONEQUIP|VENT_CONDITION|VENT_LSTYR_MJRRECONS_REPLAC|VENT_REMAIN_YRS|VENT_CSTRECONSTRUCT_REPLAC|VENT_COMMENTS|HAS_PIPED_HEATCOOL|PHEATCOOL_CONDITION|PHEATCOOL_LSTYRMJRRECONSREPLAC|PHEATCOOL_REMAIN_YRS|PHEATCOOL_CSTRECONSTRUCTREPLAC|PHEATCOOL_COMMENTS|HAS_DUCTEDHEATCOOL|DUCTEDHEATCOOL_CONDITION|DUCTHEAT_LSTYRMJRRECONSREPLAC|DUCTEDHEATCOOL_REMAIN_YRS|DUCTHEAT_CSTRECONSTRUCTREPLAC|DUCTEDHEATCOOL_COMMENTS|HAS_HVACCONTROLSYS|HVACCONTR_CONDITION|HVACCONTR_LSTYRMJRRECONSREPLAC|HVACCONTR_REMAIN_YRS|HVACCONTR_CSTRECONSTRUCTREPLAC|HVACCONTR_COMMENTS|HAS_FIREALARMSYS|FIREALRM_CONDITION|FIREALARM_LSTYRMJRRECONSREPLAC|FIREALARM_REMAIN_YRS|FIREALARM_CSTRECONSTRUCTREPLAC|FIREALARM_COMMENTS|HAS_SMOKEDETECTIONSYS|SMOKEDET_CONDITION|SMOKEDET_LSTYRMJRRECONSREPLAC|SMOKEDET_REMAIN_YRS|SMOKEDET_CSTRECONSTRUCTREPLAC|SMOKEDET_COMMENTS|HAS_FIRESUPPRESIONSYS|FIRESUPR_CONDITION|FIRESUPR_LSTYRMJRRECONSREPLAC|FIRESUPR_REMAIN_YRS|FIRESUPR_CSTRECONSTRUCTREPLAC|FIRESUPR_COMMENTS|HAS_EMERGENCYLIGHTING|EMERGLT_CONDITION|EMERGLT_LSTYRMJRRECONSREPLAC|EMERGLT_REMAIN_YRS|EMERGLT_CSTRECONSTRUCTREPLAC|EMERGLT_COMMENTS|HAS_EMERGENCYPOWERSYS|EMERGPWR_CONDITION|EMERGPWR_LSTYRMJRRECONSREPLAC|EMERGPWR_REMAIN_YRS|EMERGPWR_CSTRECONSTRUCTREPLAC|EMERGPWR_COMMENTS|HASEXTROUTEFORDISABLED|HASINTROUTEFORDISABLED|DISABILTYROUTEIMPROVEMENTCOST|EXTROUTEDISABLED_COMMENT|GENERALAPPEARANCE_RATING|GENERALAPPEARANCE_COMMENT|CLEANLINESS_RATING|CLEANLINESS_COMMENT|MATS_OVER6FTLONG|MATS_ENTRYWAY|ACOUSTICS_RATING|ACOUSTICS_COMMENTS|LIGHTINGINGENCLASSRM_TYPE|LTGENCLASSRM_RATING|LTGENCLASSRM_COMMENT|VERMIN_RODENTS|VERMIN_WOODEATING|VERMIN_COCKROACHES|VERMIN_OTHER|HAS_RIFLERANGE|RIFLERANGE_ACTIVE|HAS_MOLDWATERDMG|WHERE_MOLDWATERDMG|WHERE_MOLDWATERDMG_CMNT|NOTICABLEMOLDODOR|WHERE_MOLDODOR|WHERE_MOLDODOR_CMNT|INTSURFACES_PAPER|INTSURFACES_CELLULOSE|MOLD_CSTTOIMPROVE|MOLD_COMMENT|HUMIDITY_ROOFLEAKSCLSRM|HUMIDITY_ROOFLEAKSOTHER|HUMIDITY_PLUMLEAKSCLSRM|HUMIDITY_PLUMLEAKSOTHERAREAS|HUMIDITY_CLSRMCONDENSATION|HUMIDITY_CONDENSATIONAREAS|HUMIDITY_RATING|FRESHAIRINTKNEARBUSLOADING|FRESHAIRINTKNEARTRUCKDELIVERY|FRESHAIRINTKNEARGARBDISP|FRESHAIRINTKACCUMULATEDDIRT|FRESHAIRINTKFREEOFBLOCKAGE|DUCTWORKACCUMULATEDDIRT|DAMPERSFUNCTIONING|AIRFILTERS_CONDITION|OUTSIDEAIR_ADEQUATE|INDOORVENTILATION_RATING|INDOORVENTILATION_COMMENTS|USES_TOOLSFORSCHOOLS|OTHER_IAQ_PLANUSED|IAQ_RESPONSIBILITESASSIGNED|SCHOOLPRACTICES_IPM|VEGITATION1FTFROMBLDG|WALLFLRPVMT_CREVICESSEALED|AREPESTICIDESUSED|PESTICIDES_HOWAPPLIED|HVAC_OTHER_NOISE_INCLSRM|TESTEDFORRADON|RADON_PASSIVEMITIGATIONSYS|RADON_ACTIVEMITIGATIONSYS|RADON_DATAAVAILABLE|ISAREDCROSSEMRGNCYCTR|GENTOSUPPORTSHELTERING|SYSTEMSPOWEREDBYGEN|HASFOODPREPEQUIPINKITCHEN|WELLPUMPSCONNECTEDTOEMRGGEN|SANITARYSEWERGRAVITYDESIGN|SEWAGEPUMPSCONNTOEMERGGEN|RATINGOFSPACE|RATINGOFSPACE_CMNT|ESTOFCAPCONSTRUCTION|OVERALLBUILDINGRATING|BLDGRATINGFROMCONSULTATION|A_E_FIRM_NAME|FIRM_ADDRESS|FIRM_PHONENUM|A_E_EMAIL|A_E_NAME|A_E_LICENSE_NUMBER|SUBMISSION_ACCEPT|SUBMISSION_DATE 1|"New Hyde Park-Garden City Park UFSD"|"28040502"|"Manor Oaks School"|"0003"|"05/06/2010"|"1950 Hillside Avenue"|"New Hyde Park "|" 11040"|"ANNUAL"|"04/01/2011"|"1950"|"58,243"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"390"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"390"|"0"|"0"|||"17"|"14,020"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"E"|"1993"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"15"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2003"|"30"|"0"|"2000 Amp service"|"1"|"S"|"2003"|"15"|"0"|"Retrofit drains installed when roofs were replaced."|"0"||||"0"||"1"|"E"|"2003"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"218,300"|"Request to install Parent drop-off directly off Hillside Avenue causing less congestion during drop-off & pick-ups."|"1"|"CONCRETE,ASPHALT"|"S"|"2003"|"3"|"94,000"|"Replace various sections of sidewalk around building."|"1"|"S"|"2005"|"15"|"40,000"|"Minor ponding at fibar.Recommend F&I poured-in-place rubber surface at K play structure"|"1"|"S"|"2003"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"20"|"0"||"1"|"E"|"1950"|"20"|"0"|"Hairline stress cracks in 03 addition,stair tower,Computer Lab & Library. Caulk&paint."|"1"|"S"|"1950"|"15"|"10,000"|"Several areas of plaster repair requirqed: South stair tower, 106 & 212."|"1"|"S"|"1998"|"10"|"1,298,000"|"Replace all existing concealed spline ceiling & lighting not previously replaced."|"0"||||"0"||"1"|"S"|"E"|"2004"|"15"|"20,650"|"Replace (6) asbestos core doors."|"1"|"E"|"1950"|"25"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"1"|"S"|"2003"|"20"|"22,000"|"Gym & Boiler Room panels need upgrades."|"1"|"S"|"1998"|"10"|"0"|"Surface mounted lighting & occupany sensors only in new Admin."|"1"|"1"|"E"|"2002"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"|"Library & Administration only."|"1"|"INSTRUCT,COMMON"|"E"|"2003"|"10"|"8,000"|"All VAT removed. Replace flooring on stair landings."|"1"|"INSTRUCT,COMMON"|"S"|"1950"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2004"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"1"|"1"|"0"|"0"||"S"|"2003"|"20"|"85,000"|"3 locations require masonry repair & lintel replacement"|"1"|"MASONRY"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"E"|"E"|"1"|"1"|"2006"|"15"|"20,000"|"Replace 1 pair exterior doors & vestibule doors-Administration"|"1"|"S"|"1950"|"10"|"12,000"|"Repointing required on exterior blue stone landings."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1984"|"7"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"20"|"21,000"|"Concrete overhangs beginning to show signs of age. Visual inspections on 3 overhangs."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2009"|"20"|"0"|"New toilets in Administration wing 2009"|"1"|"IRON"|"E"|"2009"|"20"|"0"||"1"|"OIL"|"S"|"2000"|"10"|"0"||"1"|"S"|"2009"|"10"|"283,200"|"Recommend complete renovation to 4 Multi-stall toilets existing fixtures"|"0"||"1"|"BOILERSTEA"||"E"|"2000"|"25"|"0"||"1"|"E"|"2003"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"|"New RTU 2009-Admin Library 2003"|"1"|"S"|"2003"|"15"|"0"|"Install UV's in small Rms 214 & 216. No fresh air ventilation"|"1"|"S"|"2000"|"20"|"0"|"Majority of crawl space & basement piping wrapped in ACBM"|"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2003"|"5"|"100,300"|"Recommend complete pneumatic upgrade."|"1"|"E"|"2003"|"15"|"0"||"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"1"||"Toilet renovation required"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"1 FA grill blocked, clean corridor return air registers"|"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2,256,450"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/10/2010 11:04:41 AM| 2|"New Hyde Park-Garden City Park UFSD"|"28040502"|"Garden City Park School"|"0001"|"5/06/2010"|"51 Central Avenue"|"New Hyde Park"|" 11040"|"ANNUAL"|"4/1/2011"|"1926"|"43,398"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"300"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"300"|"0"|"0"|||"18"|"13,210"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"E"|"2003"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"15"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2003"|"30"|"0"|"New 2000A Service & Switchgear"|"1"|"E"|"2003"|"20"|"0"||"0"||||"0"||"1"|"E"|"2003"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"15"|"0"||"1"|"CONCRETE"|"S"|"2003"|"12"|"69,620"|"Areas around building need site improvements; replace asphalt sidewalks & curbing"|"1"|"S"|"1999"|"10"|"10,000"|"Poor drainage around playground."|"1"|"S"|"2005"|"10"|"0"|"N"|"Minor ponding after heavy rain."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"25"|"0"||"1"|"S"|"1936"|"25"|"0"||"1"|"S"|"1936"|"25"|"35,400"|"Plaster repair required at several locations."|"1"|"E"|"2003"|"5"|"486,500"|"Recommend replacing 2x4 ceiling w/2x2 & replace T-8 fluorescent light fixtures."|"0"||||"0"||"1"|"S"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"1994"|"5"|"171,000"|"Replace entire ceiling w/2x2 tile & T-5 fluorescent light fixtures."|"1"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2003"|"8"|"0"||"1"|"INSTRUCT"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2005"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"25"|"0"||"CONCRETE"|"0"|"0"||"0"|"0"|"0"|"1"|"0"||"S"|"2005"|"15"|"0"||"1"|"MASONRY"|"S"|"1996"|"20"|"14,000"|"Replace chimney cap & install new counterflashing."|"1"|"MASONRY"|"S"|"2005"|"15"|"0"||"S"|"S"|"1"|"1"|"2006"|"15"|"32,450"|"Replace remaining exterior doors w/new FRP, aluminum frames & hardware."|"1"|"S"|"1936"|"15"|"30,680"|"Repoint & repair remaining exterior steps & landings from all exits."|"0"|||||"0"||"1"|"STEEL"|"U"|"Y"|"1982"|"2"|"858,273"|"Replace all windows except 03 addition. Replaced approx 1980"|"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"7"|"0"|"Active leak around Gym roof drain."|"1"|"GLASS"|"E"|"1996"|"7"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2003"|"15"|"0"||"1"|"IRON"|"S"|"2003"|"15"|"0"||"1"|"OIL"|"S"|"1985"|"6"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"118,000"|"4 rooms need to be addressed regarding mechanical ventilation"|"1"|"S"|"2008"|"2"|"324,500"|"Floor gets hot - new steam-to-hot-water heat exchanger should be installed in boiler room."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"118,000"|"Recommend install zone valves @ boiler room. Expand DDC system; Upgrade compressor; Rehabilitate pneumatic controls on unit vents."|"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"1"|"101,480"|"Create 1 lg ADA toilet @ Nurse's Office"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"|"0"|"FAIR"||"2,370,003.00"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/10/2010 2:45:16 PM| 3|"New Hyde Park-Garden City Park UFSD"|"28040502"|"Hillside Grade School"|"0002"|"05/06/2010"|"150 W. Maple Drive"|"New Hyde Park"|" 11040"|"ANNUAL"|"4/1/2011"|"1947"|"69,293"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"468"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"468"|"0"|"0"|||"25"|"20,932"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1947"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"15"|"0"|"Clogged line replaced at west side of building."|"1"|"E"|"2003"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2003"|"30"|"0"||"1"|"E"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"15"|"30,680"|"Recommend area south to Kindergarten play area & replacing sidewalks at north end."|"1"|"CONCRETE"|"S"|"2003"|"20"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2003"|"25"|"0"||"1"|"S"|"1947"|"25"|"0"||"1"|"S"|"1947"|"25"|"22,000"|"Plaster repair required at multiple locations."|"1"|"S"|"2005"|"15"|"360,000"|"The cost above is to replace remaining classroom & office concealed spline ceilings."|"1"|"E"|"2005"|"20"|"0"||"1"|"S"|"S"|"2004"|"10"|"0"||"1"|"S"|"1947"|"20"|"0"||"0"||||"0"||"1"|"0"|"S"|"2003"|"10"|"35,000"|"Additional sub-panels required to meet building's needs."|"1"|"S"|"1996"|"5"|"276,120"|"District to consider installing new access panels. Recommend removing existing pendant hung fixtures w/new T-5 & T-8 fixtures."|"1"|"1"|"E"|"2002"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT"|"E"|"2003"|"15"|"0"||"1"|"COMMON"|"S"|"1947"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2004"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"15"|"383,500"|"Recommend reside all exterior wood trim with aluminum. All rotten wood trim replaced with new wood."|"1"|"MASONRY"|"S"|"2005"|"20"|"0"||"1"|"MASONRY"|"S"|"2005"|"20"|"0"||"S"|"S"|"1"|"1"|"2008"|"15"|"35,400"|"Recommend replacing 4 pairs of existing exterior doors, frames & hardware w/new FRP doors, 2x6 aluminum frames & hardware."|"1"|"S"|"1947"|"5"|"44,840"|"Repoint exterior concrete steps along south & wes side of bldg. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1982"|"3"|"283,200"|"Replace upper porcelain enamel panels of windows."|"METONMET,CONMETMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"12"|"48,000"|"Recommend cleaning entire cupola & installing addtional access panels."|"0"|||||"0"||"1"|"GALVANIZED"|"S"|"1947"|"15"|"0"||"1"|"IRON"|"S"|"1947"|"15"|"0"||"1"|"OIL"|"S"|"1996"|"10"|"0"||"1"|"E"|"2003"|"20"|"0"||"0"||"1"|"BOILERSTEA"||"E"|"1996"|"20"|"0"||"1"|"E"|"1996"|"20"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"2003"|"12"|"206,500"|"All student-occupied spaces shall be mechanically ventilated"|"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"75,000"|"Steam traps should be replaced in entire bldg. "|"1"|"E"|"2002"|"15"|"0"||"1"|"E"|"2002"|"15"|"0"||"0"||||"0"||"1"|"E"|"2005"|"20"|"0"||"0"||||"0"||"1"|"0"|"1,183,540"|"Consider installation of elevator & create large toilet at Nurse's Office"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"GOOD"||"2,940,580"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/10/2010 4:46:04 PM| 4|"New Hyde Park-Garden City Park UFSD"|"28040502"|"New Hyde Park Road School"|"0004"|"5/06/2010"|"300 New Hyde Park Road"|"New Hyde Park"|" 11040"|"ANNUAL"|"4/1/2011"|"1928"|"57,113"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"500"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"500"|"0"|"0"|||"27"|"21,202"|"ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1985"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1928"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1928"|"15"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2003"|"25"|"0"||"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"429,520"|"Existing north east parking lot needs asphalt pavement & drainage."|"1"|"CONCRETE"|"S"|"2003"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1928"|"25"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"1928"|"20"|"0"||"1"|"S"|"2003"|"5"|"663,232"|"Replace ceilings w/2x2 acoustical tiles & 2x4 T-8 recessed lighting."|"1"|"S"|"1950"|"6"|"0"||"1"|"S"|"S"|"2004"|"10"|"0"||"1"|"S"|"1928"|"10"|"0"||"1"|"E"|"2003"|"25"|"0"||"1"|"0"|"S"|"1990"|"6"|"28,000"|"Provide additional panels to address building needs."|"1"|"S"|"2003"|"10"|"44,840"|"Lighting should be replaced w/energy efficient T-5 fluorescent lighting fixtures."|"1"|"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"127,440"|"Replace all VCT w/VET. Testing must be done to verify VCT does/does not contain asbestos."|"1"|"INSTRUCT"|"U"|"1928"|"2"|"159,300"|"Remove loose/flaking paint of Gym's concrete steps & bleachers,under proper conditions & install raised rubber flooring over existing surface."|"1"|"INSTRUCT"|"E"|"1999"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"1"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2003"|"25"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"2008"|"20"|"129,800"|"Several areas still need attention to building's exterior masonry."|"1"|"MASONRY"|"S"|"1998"|"20"|"0"||"1"|"MASONRY"|"S"|"2006"|"15"|"0"||"S"|"S"|"1"|"1"|"2003"|"4"|"54,280"|"Recommend replacing remaining hollow metal exterior doors w/FRP doors, hardware & 2x6 aluminum frames."|"1"|"S"|"1928"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"3"|"911,196"|"Replace w/new dual sash, single glazed, horizontal sliding windows similar to new addition."|"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1928"|"15"|"0"||"1"|"IRON"|"S"|"1928"|"15"|"0"||"1"|"OIL"|"E"|"2003"|"15"|"0"||"1"|"E"|"2003"|"20"|"0"||"0"||"1"|"BOILERSTEA"||"E"|"2003"|"20"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"295,000"|"Exterior spaces to be naturally ventilated by means of windows in at least 10 rooms that do not meet requirements. or equipped w/mechanical cooling if natural cooling cannot maintain 74 deg F."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"5"|"100,300"|"Steam valves should be replaced in original bldg & compressor should be thoroughly serviced. Recommend thorough calibration of panel to ensure up to date."|"1"|"E"|"2003"|"15"|"0"||"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"1"|"E"|"2003"|"20"|"0"||"0"||||"0"||"1"|"1"|"115,640"|"Reconfigure Nurse's Office to creat 1 large ADA toilet"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"GOOD"||"3,058,548"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/12/2010 11:09:27 AM| 5|"Hopevale UFSD At Hamburg"|"14160302"|"HOPEVALE SCHOOL"|"0001"|"08/25/2010"|"3780 HOWARD ROAD PO BX828"|"HAMBURG "|" 14075"|"ANNUAL"|"12/01/2010"|"1992"|"43,000"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"123"|"7,8,9,10,11,12"|"0"|"1"|"0"|"123"|"0"|"0"|||"27"|"21,500"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,SCIENCELAB,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"1992"|"10"|"0"|"Excavate run off and drainage trench accumulations. provide stone base"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"|"Parking and roadways maintained by Hopevale Inc."|"1"|"CONCRETE"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"Playing fields and green space owned and operated by Hopevale Inc."|"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"15"|"0"|"Small stress cracks visible"|"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"7"|"0"|"Some broken tiles, mismatched, and water stained areas "|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"S"|"1992"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1992"|"3"|"0"|"Worn areas and ripped carpet. High traffic areas"|"1"|"INSTRUCT,COMMON"|"S"|"1992"|"5"|"0"|"Cracking and popping tiles at joints. science room 42 has worst vct condition "|"1"|"COMMON"|"S"|"1992"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"15"|"0"|"Surface cracks visible. No heaving"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1992"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"15"|"0"|"bronze finish is faded "|"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"1992"|"3"|"645,000"|"Ballast membrane. Has active leaks, areas of standing water, and poorly functioning roof drains. Regular maintenance is required to maintain roof. Leaks becoming more frequent."|"1"|"PLASTIC"|"S"|"1992"|"7"|"0"||"1"|"IRON"|"S"|"1992"|"10"|"0"||"1"|"IRON"|"S"|"1992"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"7"|"0"|"Bell Gossett motor replaced in 1999. heating system and concrete pad recently replaced "|"1"|"S"|"1992"|"5"|"0"|"some sinks missing fixtures and drinking fountains are not ADA accessible "|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1992"|"7"|"0"|"Bell Gossett motor replaced in 1999. heating system and concrete pad recently replaced "|"0"||||"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"15"|"0"|"Onan Genset generator model 453ml natural gas 3 phase and single phase "|"1"|"1"|"2000"|"Asphalt ramp from parking to sidewalk is non compliant and has deteriorated . Add handicapped signage at doors"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"hallways are dim but classrooms have acceptable lighting levels"|"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|"0"|"some stained act tiles, but currently no mold or mildew growth"|"1"|"0"|"0"|"0"|"1"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"1"|"LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"647,000"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|11/15/2010 12:45:28 PM| 6|"Manhasset UFSD"|"28040603"|"Munsey Park Elementary School"|"0001"|"04/26/2010"|"1 Hunt Lane"|"Manhasset"|" 11030"|"ANNUAL"|"04/01/2010"|"1939"|"131,367"|"3"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"953"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"953"|"0"|"0"|||"39"|"21,050"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"2"|"21,000"|"S"|"1998"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"|"Pump out overflow pools on an as-needed basis."|"1"|"S"|"1980"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1986"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"U"|"1999"|"10"|"54,000"|"Addtional drainage structures required. Recommend install pre-cast drywells @ north lot & Auditorium."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"15"|"71,200"|"South Faculty lot in need of complete replacement."|"1"|"CONCRETE"|"E"|"2008"|"15"|"8,000"|"Small section of sidewalk at Auditorium needs to be repaired."|"1"|"E"|"2008"|"15"|"76,000"|"Recommend installation of new poured-in-place safety surfacing below play structures."|"1"|"S"|"2006"|"10"|"235,000"|"Y"|"Remove backstops & clay infield & install proper sub-surface drainage & lawn at furthest field from school."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"20"|"0"||"1"|"S"|"1962"|"15"|"0"||"1"|"S"|"1962"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"E"|"2008"|"20"|"0"|"Recommend replacement of interior doors."|"1"|"S"|"1999"|"15"|"0"||"1"|"E"|"1999"|"20"|"0"||"1"|"0"|"S"|"1999"|"10"|"7,000"|"Art Room outlets needed & panels not labeled."|"1"|"E"|"2009"|"20"|"0"|"Replaced as part of ESCO."|"1"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2007"|"10"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"INSTRUCT"|"E"|"1962"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"CONCRETE,MASONRY,WOOD,OTHER"|"0"|"1"|"Concern w/existing stucco"|"1"|"1"|"1"|"1"|"1"||"S"|"2007"|"15"|"468,750"|"Exteriorstucco in need of waterproofing at 1999 addition."|"1"|"MASONRY"|"E"|"2007"|"20"|"0"||"1"|"MASONRY"|"S"|"2007"|"20"|"0"||"E"|"E"|"1"|"1"|"2009"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1986"|"7"|"12,000"|"Counter balance replacement required in some locations. Replace 1 window in Boiler Room."|"METONMET,WOODONWOOD,CONMETMET,OTHER"|"BUILTUP,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"Flashing at Library roof."|"E"|"2007"|"20"|"21,000"|"Repairs & waterproofing required at Library wall & flashing."|"0"|||||"0"||"1"|"COPPER"|"S"|"2008"|"10"|"0"|"Portions upgraded during bathroom renovation."|"1"|"IRON,COPPER"|"S"|"1999"|"10"|"0"|"Portions upgraded during bathroom renovation."|"1"|"OIL"|"S"|"1990"|"5"|"30,000"|"Recommend replacementof existing hot water heater."|"1"|"E"|"2007"|"20"|"0"|"Recommend replacement of remaining fixtures & upgrading bathrooms. "|"0"||"1"|"BOILERWATE"||"S"|"1960"|"15"|"0"|"New burners installed 2010."|"1"|"S"|"1960"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"115"|"0"|"Building-wide refurbishment done in 2008."|"1"|"E"|"2008"|"15"|"0"|"Building-wide refurbishment done in 2008."|"1"|"E"|"2008"|"15"|"0"|"Complete rehab took place in 2008."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1995"|"1995"|"0"|"Kitchen hood inspected periodically."|"1"|"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"|"Full building coverage."|"1"|"1"|"255,000"|"Complete reconstruction of 3 multi-stall & 5 single stall toilets."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,INCANDESCE"|"GOOD"|"ESCO completed in 2009"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"||"FAIR"|"Addtional teaching space & Cafeteria space needed."|"1,237,950"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/15/2010 12:49:33 PM| 8|"Medina CSD"|"45080106"|"Medina High School"|"0006"|"11/4/09"|"11235 Maple Ridge Road"|"Medina"|" 14103"|"ANNUAL"|"07/1/11"|"1991"|"114250"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"606"|"9,10,11,12"|"0"|"1"|"1"|"606"|"0"|"0"|||"36"|"28600"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"500"|"0"|"0"|"E"|"2003"|"18"|"0"|"Above ground fuel tanks with fence and containment installed in 2003."|"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"|"Secondary supply installed in 2003 project."|"1"|"MUN_UTILIT"|"S"|"2009"|"25"|"0"|"New pump station installed in 2003. New pump discharge line to street in 2009."|"1"|"E"|"2009"|"30"|"0"|"Replaced gas service main and upgraded gas meter regulator setting in 2009."|"1"|"UTIL"|"BELOW"|"E"|"1991"|"20"|"0"||"0"||||"0"||"1"|"S"|"1991"|"20"|"0"|"No reported issues."|"1"|"S"|"1991"|"20"|"0"|"No reported issues."|"1"|"S"|"1991"|"20"|"0"|"No reported issues."|"1"|"MUNI"||"0"|"S"|"1991"|"20"|"0"|"No reported issues."|"0"||||"0"||"1"|"S"|"2003"|"15"|"0"|"Retention basin was reformed in 2003."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"CONCRETE"|"S"|"2009"|"15"|"6600"|"Replace section near basement door in district office."|"0"||||"0"||"1"|"S"|"2009"|"25"|"86900"|"Y"|"Cost is for resurfacing the track. Consider replacing the turf in the next 6 years. Turf is beyond original 8 year warranty."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"25"|"0"|"Sump pumps installed in 2009 to eliminate water penetration."|"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1991"|"3"|"193347"|"Replace original ceiling tiles and grid."|"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"S"|"2009"|"15"|"34001"|"Added new lever sets at corridors doors in 2009. Additional hardware updates required. New stainless steel doors in pool 2009."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"1"|"S"|"1991"|"20"|"0"|"Branch circuit panels added in 2009."|"1"|"E"|"2009"|"20"|"0"|"All interior lights replaced in 2009."|"1"|"1"|"S"|"2003"|"10"|"0"|"No reported issues."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"37924"|"Replace carpet in Main Offices, and Faculty Break Room."|"1"|"INSTRUCT,COMMON"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1991"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"25"|"0"|"Steel added to support existing folding partition in 2009."|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"25"|"0"|"New thru wall flashing at upper walls where they meet the roof in 2009."|"1"|"MASONRY"|"S"|"1991"|"10"|"0"||"1"|"MASONRY"|"S"|"2009"|"25"|"0"|"Ran new roofing up the back of the parapet in 2009 and resealed all joints in the stone coping."|"S"|"S"|"1"|"1"|"2009"|"15"|"0"|"New security system installed in 2009."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1991"|"6"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"24"|"0"|"Roof was replaced as part of the last capital project. The area over the District Office was not replaced (vintage 2002)."|"1"|"PLASTIC"|"S"|"1991"|"15"|"0"||"1"|"COPPER"|"E"|"1991"|"20"|"0"|"No reported issues."|"1"|"IRON,COPPER"|"E"|"1991"|"20"|"0"|"No reported issues."|"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"|"New water heaters and storage tanks installed in 2009."|"1"|"S"|"1991"|"15"|"0"|"Replace lavatory faucets in next capital project."|"0"||"1"|"BOILERWATE"||"S"|"1991"|"10"|"0"|"No reported issues."|"1"|"S"|"2009"|"15"|"0"|"No reported issues."|"1"|"S"|"2009"|"20"|"0"|"Administration Office, Library and Auditorium have new ACU's."|"1"|"S"|"2009"|"20"|"0"|"Kitchen and Gym have new AHU's."|"1"|"S"|"1991"|"10"|"50000"|"Replace hot water heating pumps and add boiler blend pumps."|"1"|"S"|"2009"|"10"|"72000"|"Improve locker room ventilation and add kitchen space heating."|"1"|"E"|"2009"|"20"|"0"|"DDC upgrate completed in 2009."|"1"|"S"|"1991"|"5"|"145000"|"Only main fire alarm control panel replaced in 2009."|"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"1991"|"1991"|"0"|"District shall continue to have annual kitchen hood supression system inspection."|"1"|"E"|"2009"|"20"|"0"|"Emergency exit lighting systems updated in 2009."|"1"|"S"|"1991"|"5"|"0"|"No reported issues."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"1"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"1480767"|"S"|"1"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York, 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/15/2010 2:58:02 PM| 9|"Manhasset UFSD"|"28040603"|"Shelter Rock Elementary School"|"0005"|"04/26/2010"|"27A Shelter Rock Road"|"Manhasset"|" 11030"|"ANNUAL"|"04/01/2011"|"1962"|"133,357"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"750"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"750"|"0"|"0"|||"33"|"32,995"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1990"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1983"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"15"|"0"|"Feeds boilers, hot water heater, Kitchen 7 generator."|"1"|"UTIL"|"BELOW"|"S"|"1968"|"10"|"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"S"|"1962"|"10"|"40,000"|"Additional drainage structures required to address ponding."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"2"|"180,000"|"Asphalt playground area needs new pavement. Recommend recycling in place existing asphalt w/new sub-base. Repave entire area."|"1"|"CONCRETE"|"S"|"1999"|"5"|"42,000"|"Concrete sidewalk needs replacement. Also recommend opening entrance driveway."|"1"|"S"|"1999"|"10"|"96,000"|"Replace fibar & drainage mat, & construct low retaining wall around portion of playground - area holds water after rain."|"1"|"S"|"2000"|"8"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"1"|"S"|"2007"|"20"|"0"|"Repair to small Gym during last Bond Issue."|"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2008"|"4"|"820,000"|"Corridor celings to be replaced & install ACT ceilings in classrooms."|"1"|"S"|"1968"|"8"|"0"||"1"|"E"|"E"|"2007"|"20"|"0"||"1"|"S"|"1968"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"|"No accessibility to upper spaces over Main Office - Recommend relocate program to accommodate accesibility."|"1"|"1"|"S"|"1999"|"10"|"0"||"1"|"E"|"2009"|"20"|"0"|"Upgrade lighting as part of ESCO"|"1"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2008"|"12"|"197,000"|"Replace remaining stair tower VAT & corridor VCT with new VET."|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1962"|"20"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"20"|"68,000"|"Provide stucco finish over exposed concrete. Match window color."|"1"|"MASONRY"|"S"|"2008"|"20"|"12,000"|"Replace existing metal chimney cap."|"0"|||||"0"||"E"|"E"|"1"|"1"|"2008"|"20"|"0"||"1"|"E"|"2007"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2007"|"20"|"0"||"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"20"|"0"||"1"|"GLASS"|"E"|"2007"|"20"|"0"||"1"|"COPPER"|"S"|"2008"|"10"|"0"|"Portions upgrade during bathroom renovation."|"1"|"IRON,COPPER"|"S"|"2008"|"10"|"0"|"Portions upgraded during bathroom renovation."|"1"|"NAT_GAS"|"S"|"1998"|"10"|"0"||"1"|"E"|"2008"|"20"|"0"|"Recommend replacement of fixtures in remaining 4 toilets."|"0"||"1"|"BOILERWATE"||"E"|"2007"|"40"|"0"||"1"|"E"|"2007"|"40"|"0"||"1"|"S"|"2000"|"3"|"240,000"|"Replace A/C in Auditorium; provide A/C in Cafeteria."|"1"|"E"|"2009"|"15"|"0"|"Rehabilitation completed summer 2009"|"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"E"|"2009"|"15"|"0"|"Complete rehab in 2009. Non-functioning UV blowers replaced."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1995"|"1995"|"0"|"Kitchen system reinspected annually."|"1"|"E"|"2009"|"10"|"0"|"Upgraded as part of ESCO."|"1"|"S"|"1968"|"5"|"650,000"|"Geerator needs replacement. "|"1"|"1"|"240,000"|"Renovate 4 remaining toilets to ADA."|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"|"Lighting replaced as part of ESCO."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|"COMMSYS"|"FULL"|"0"|"1"||"GOOD"||"2,585,000"|"E"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/15/2010 4:25:18 PM| 11|"Sackets Harbor CSD"|"22100104"|"Sackets Harbor Central School"|"0001"|"04/28/2010"|"215 South Broad Street"|"Sackets Harbor"|" 13685"|"ANNUAL"|"04/04/2011"|"1928"|"107,590"|"3"|"5"|"1"|"DISTRICT"|"INSTRUCT"||"496"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"1"|"0"|"1"|"496"|"0"|"0"|||"29"|"23,576"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"1"|"500"|"0"|"0"|"S"|"1992"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"U"|"2000"|"3"|"18,850"|"Section of pipe below driveway in front of the bus garage is deteriorated and needs to be replaced."|"1"|"S"|"1992"|"15"|"0"||"1"|"UTIL"|"BELOW"|"E"|"1992"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"|"This is now considered a wetland per DEC."|"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"15"|"0"||"0"|"CONCRETE"|"U"|"2009"|"1"|"24750"|"The sidewalk in the front of the building is in a severely deteriorated state and needs to be replaced. This was identified in the 2005 BCS."|"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"1"|"1"|"0"|"0"|"S"|"2009"|"5"|"10,000"|"Repair areas where corners have been hit by plows and/or damaged due to water infiltration."|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2009"|"5"|"7,500"|"Basement walls should be cleaned up, plaster repair and painted."|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2000"|"5"|"85,100"|"As identified by the District prior to the last project, the 6" wide lockers are very small and should be replaced with 12" lockers for student functionality."|"1"|"S"|"U"|"2000"|"5"|"95,000"|"All corridor doors should be fire rated. With the exception of the 2000 additions, noe are."|"1"|"S"|"2009"|"15"|"0"||"1"|"U"|"1998"|"0"|"10,000"|"The elevator is continually written up in the yearly inspections for certain safety items missing."|"1"|"1"|"S"|"2000"|"5"|"6,000"|"Panel&switchboards are missing arc flash hazard stickers required by NEC & NFPA. Approx 15 projectors have cords extending up into the ceiling cavity which is in violation of NEC. Most panelboards are in good shape & have spare capacity."|"1"|"S"|"2009"|"5"|"15,000"|"Most area are T8 ballasts. Basement areas are exist T12 as well as incandescent & should be replaced with energy efficient T8 or CFL lamps. Exterior lighting is not pulse start type HID, suggest upgrading to pulse start metal halide."|"1"|"1"|"S"|"2000"|"5"|"5,000"|"Phone system is conventional, lwatsu 5159 and is approx 10 years old. Punchdown is type 66 blocks & system wiring/termination is sloppy & should be corrected. Intercom system is approx 10 years old, CPU may need to be upgraded in the near future."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"5"|"3,822"|"Carpet in Psychologist suite is in need of replacement."|"0"|"INSTRUCT,COMMON"|"S"|"2009"|"2"|"96,100"|"Areas where the VCT is over the wood subfloor needs to be replaced. These include the science rooms, MPR and other rooms in the 1928 portion of the building and stair nosings."|"1"|"COMMON"|"S"|"2000"|"5"|"9,000"|"Replace delaminated terrazzo at the gymnasium main entry vestibule."|"0"|"INSTRUCT"|"S"|"2000"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"Settlement cracks and holes from removed equipment"|"S"|"2000"|"5"|"54,872"|"Several cracks in the masonry should be repaired before water infiltration and freeze/thaw make worse. Lintles require scrape and paint."|"1"|"MASONRY"|"S"|"1928"|"3"|"22,500"|"Masonry Restoration of the brick and mortar joints is required."|"1"|"MASONRY"|"S"|"2009"|"10"|"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"0"||"1"|"S"|"2000"|"5"|"15,000"|"The concrete stair at the loading dock is in need of replacement."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"5"|"112,500"|"Several windows in the elementary wing were not replaced and the seals are broken, little thermal value. Windows in music suite are pulling away from the jambs leaving large gaps."|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"2009"|"1"|"3,825"|"EPDM membrane is shrinking and if not repaired will cause masonry failure of the parapet wall."|"1"|"PLASTIC"|"S"|"2000"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2009"|"5"|"52,000"|"Piping below Boys Toilet and Kitchen needs to be replaced, several leaks."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2009"|"3"|"150,000"|"Sanitary piping below kitchen and other portions of 1928 bldg need replacement. Sewage ejector under building needs new pump and rails."|"1"|"OIL"|"S"|"2001"|"6"|"0"||"1"|"S"|"2009"|"5"|"50,800"|"Add drains to eye stations, add emergency shut-off to gas in science rooms, replace sinks & faucets in science rooms, update disposal and dishwash units."|"1"|"CV"|"1"|"BOILERSTEA"||"U"|"1987"|"2"|"500,000"|"Boilers have a life expectancy of 30 years. There is a 1982 and 1987 boiler. Both have cause problems and are nearing the end of their useful life."|"1"|"S"|"1987"|"10"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"5"|"200,000"|"The air handling units located in the gymnasium mezzanine are not functional."|"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"5"|"0"|"The existing Johnson Controls installed in the 1999 project serving the gymnasium addition are not functioning properly."|"1"|"S"|"2009"|"15"|"0"||"1"|"U"|"2009"|"1"|"50,000"|"Severala horn/strobe devices are not located within 15' from the end of the corridor. No strobe devices in individual classrooms. Coverage does not meet NFPA or NYS Code."|"1"|"U"|"2000"|"2000"|"20,000"|"No electrical shubt trip mechanism to remove power from equipment below kitchen hood upon activation of release agaent. Ansul system not connected to annunciator at alarm panel."|"1"|"U"|"2000"|"0"|"10,000"|"Existing exit signs are not LED type for energy savings. Exit signs do not meet current life safety requirements."|"1"|"S"|"2009"|"15"|"0"||"1"|"1"|"93,500"|"Door hardware should be changed to lever style locksets for ADA compliance."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE,OTHER"|"FAIR"|"Few incandescent fixtures were present, mostly in boiler room, mechanical room and crawl space. "|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"1"|"1"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"There is a room that was a storage room and now an office that will require outside air."|"0"|"1"|"0"|"1"|"1"|"0"|"0"||"1"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"||"0"|"1"|"GOOD"||"1,781,119"|"U"|"0"|"Bernier, Carr - Associates, PC"|"327 Mullin Street"|"315-782-8130"|"jjantzi@thebcgroup.com"|"Jason S. Jantzi"|"029165"|"I ACCEPT"|11/16/2010 1:46:16 PM| 13|"Sackets Harbor CSD"|"22100104"|"SHCSD Bus Garage"|"5002"|"04/28/2010"|"BROAD ST "|"SACKETS HARBOR "|" 13685"|"ANNUAL"|"04/11/2011"|"1928"|"4888"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus storage and maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"|"Unable to determine exact year of last reconstruction."|"1"|"S"|"1992"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"10"|"0"|"Unable to determine year of last reconstion. Power is fed from the school."|"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"15"|"0"|"Unable to determine exact year of last reconstruction."|"1"|"S"|"1992"|"5"|"15,000"|"A fire wall between the maintenance bay and offices is required."|"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"15"|"0"||"0"||||"0"||"1"|"U"|"1998"|"5"|"120,000"|"The vehicle lift pit/foundation is failing and needs to be replaced along with the components of the lift that sit in the pit."|"1"|"1"|"U"|"1992"|"5"|"10,000"|"Older GE panel is in poor condition. Newer Challenger panel is in satisfactory condition. There are a few receptacles that need to be replaced with GFI type."|"1"|"S"|"1992"|"5"|"2,000"|"There are some T12 ballasts that should be replaced with T8 ballasts."|"1"|"0"|"U"|"1992"|"0"|"2,000"|"The District has indicated that 2 out of the 3 phone lines to the main school building are not operational."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||"S"|||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1992"|"1992"|"24,295"|"The concrete floor is cracked in most areas and starting to fail. Seal cracks in storage bays and replace floor slab in wash bay and maintenance bay."|"MASONRY"|"0"|"0"||"1"|"0"|"1"|"1"|"1"||"U"|"1992"|"3"|"142,000"|"Walls are cracking and water penetration is severe. Moss is growing out of joints and many masonry units are deteriorating."|"0"|"MASONRY"|"S"|"1928"|"5"|"0"|"The price for maosnry rehabilitation is included in the item above."|"0"|||||"0"||"U"|"U"|"0"|"0"|"1992"|"4"|"48,800"|"Overhead doors are rusting, little to no weather stripping. According to school personnel, safety devices are not working."|"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1992"|"6"|"0"||"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"U"|"2009"|"2"|"144,750"|"EPDM membrane is shrinking, several leaks around equipment, out of warranty and should be replaced."|"0"|||||"0"||"1"|"IRON"|"S"|"1992"|"10"|"0"||"1"|"COPPER"|"S"|"1992"|"10"|"0"||"0"|"NAT_GAS"|"S"|"1992"|"4"|"1,200"|"Hot water heater has served its useful life and should be replaced."|"1"|"U"|"1992"|"3"|"2,000"|"Replace with ADA compliant fixtures."|"0"||"1"|"OTHER"|"Unit Ventilation"|"S"|"1992"|"6"|"0"|"These are Trane gas fired unit heaters."|"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1992"|"6"|"0"|"There is a wall thermostat for each unit heater."|"1"|"U"|"1992"|"0"|"8,000"|"Notification devices not up to Code. Panel is obsolete, conventional type."|"1"|"U"|"1992"|"0"|"2,000"|"Detection coverage not up to Code."|"0"||||"0"||"0"|"U"|"1992"|"0"|"5,000"|"No existing emergency lighting fixtures. Exit lights are not LED type and in poor condition."|"0"||||"0"||"0"|"0"|"25,000"|"Toilet room needs to be renovated/enlarged for ADA compliance."|"POOR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE,OTHER"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Maintenance and storage bays"|"0"|||"0"|"0"|||"0"|"1"|"0"|"0"|"0"|"1"|"POOR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"552,045"|"U"|"0"|"Bernier, Carr Associates"|"327 Mullin Street, Watertown, NY"|"315-782-8130"|"jjanzti@thebcgroup.com"|"Jason S. Jantzi, AIA"|"029165"|"I ACCEPT"|11/16/2010 8:51:31 PM| 14|"Bethpage UFSD"|"28052103"|"CENTRAL BOULEVARD ELEMENTERY"|"0003"|"07/19/2010"|"60 CENTRAL BOULEVARD"|"BETHPAGE"|" 11714"|"ANNUAL"|"04/01/2010"|"1955"|"70,200"|"3"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"550"|"K,1,2,3,4,5"|"0"|"1"|"1"|"550"|"0"|"0"|||"25"|"23,300"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1992"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1989"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"|"Kitchen equipment & burner pilots"|"1"|"UTIL"|"BELOW"|"S"|"1955"|"7"|"0"|"Transformer vault located below grade."|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"12"|"0"||"0"|"CONCRETE"|"S"|"2002"|"12"|"20,000"|"Replace miscellaneous sections of sidewalk along front entrance."|"1"|"E"|"2007"|"15"|"0"||"1"|"S"|"2006"|"12"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1955"|"15"|"0"||"1"|"S"|"2010"|"10"|"9,000"|"Interior wall masonry cracked addressed in 2010. Remaining masonry cracks to be repaired."|"1"|"S"|"2010"|"15"|"13,000"|"Repair crack in K vestibule; Replace window in Gym Coaches' Office; Reconstructoin of corridor walls in main corridor."|"1"|"U"|"2007"|"3"|"635,900"|"Concealed spline ceilings in some locations should be replaced in the immediate future."|"1"|"S"|"1955"|"15"|"0"||"1"|"S"|"S"|"2007"|"12"|"176,500"|"Many corridor doors do not need ADA-should be replaced; Knob type hardward should be replaced with high security lever type; all held-open devices removed & replaced. "|"1"|"S"|"1955"|"15"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"1"|"S"|"2003"|"10"|"5,000"|"1600 amp circut breaker-main service switch. Recommend cleaning & infra-red tested."|"1"|"E"|"2007"|"15"|"0"||"1"|"1"|"S"|"1987"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2003"|"12"|"0"||"1"|"INSTRUCT"|"S"|"2003"|"15"|"270,000"|"Recommend replacementof remaining VAT flooring."|"1"|"COMMON"|"E"|"1955"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2007"|"12"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1955"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2007"|"15"|"65,000"|"Must still address several locations on exterior masonry"|"1"|"MASONRY"|"E"|"2007"|"20"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2004"|"15"|"20,000"|"Replace 2nd floor FanRoom door & frame."|"1"|"S"|"1955"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"20"|"0"||"METONMET,CONMETMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2003"|"10"|"0"|"Leaks in 2 areas reported at time of walk-thru. Roof under warranty."|"0"|||||"0"||"1"|"COPPER"|"S"|"2008"|"6"|"0"|"Detailed study needed to see if repairs or complete replacement is required on several leaks in the water distribution system."|"1"|"GALVANIZED"|"S"|"2007"|"15"|"0"|"Portions replaced as part of bathroom renovation."|"1"|"OIL"|"S"|"2002"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"|"Fixtures replaced on 1st & 2nd floor multi-stall toilet."|"0"||"1"|"BOILERSTEA"||"S"|"1955"|"5"|"550,000"|"Recommend replacement of Boiler/Burners & related boiler replacement."|"1"|"S"|"1955"|"5"|"550,000"||"1"|"S"|"2003"|"12"|"0"||"1"|"S"|"2010"|"15"|"34,000"|"Provide mechanical ventilation in Room 109A & Conference Room D."|"1"|"S"|"1955"|"6"|"0"||"1"|"S"|"1955"|"6"|"0"||"1"|"S"|"2003"|"5"|"42,000"|"Building pneumatic refurbishment recommended."|"1"|"S"|"2003"|"15"|"0"|"Simplex Series 4010"|"1"|"S"|"2003"|"15"|"0"|"Simplex Series 4010"|"1"|"S"|"2003"|"2003"|"0"|"Inspected February 2010"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"1"|"64,000"|"Provide 1 ADA sink/bubbler combo; Provide portable chairlift for accessibility to Stage"|"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"0"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"0"|"1"||"FAIR"||"2,436,400"|"U"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/17/2010 10:49:15 AM| 15|"Glens Falls Comn SD"|"63091808"|"Wing Classroom Building"|"0001"|"11/02/2010"|"120 Lawrence Street"|"Glens Falls"|" 12801"|"ANNUAL"|"01/01/2011"|"1936"|"23204"|"3"|"1"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"160"|"K,1,2,3"|"0"|"1"|"1"|"160"|"0"|"0"|||"16"|"7780"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,SPECED"||"1"|"0"|"0"|"1"|"1000"|"S"|"1980"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"30"|"0"||"1"|"S"|"1996"|"30"|"0"||"1"|"UTIL,SELF"|"BELOW"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"0"||||"0"||"1"|"S"|"2008"|"30"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"30"|"0"||"1"|"CONCRETE"|"S"|"2008"|"30"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"50"|"0"||"1"|"S"|"2008"|"35"|"0"||"1"|"S"|"2008"|"35"|"0"||"1"|"S"|"2008"|"35"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"35"|"0"||"1"|"S"|"1936"|"30"|"0"||"1"|"S"|"1996"|"30"|"0"||"1"|"1"|"S"|"2008"|"35"|"0"||"1"|"S"|"2008"|"35"|"0"||"1"|"1"|"S"|"2008"|"35"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"35"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"35"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"35"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"35"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"35"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"35"|"0"||"1"|"MASONRY"|"S"|"1936"|"30"|"0"||"1"|"MASONRY"|"S"|"1997"|"30"|"0"||"S"|"S"|"0"|"1"|"1996"|"30"|"0"||"1"|"S"|"1996"|"30"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"35"|"0"||"METONMET,WOODONWOOD"|"SINGLEPLY,ASPHALT,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"35"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1996"|"30"|"0"||"0"|"IRON,COPPER"|"S"|"1996"|"30"|"0"||"1"|"OIL"|"S"|"2003"|"15"|"0"||"1"|"S"|"2009"|"30"|"0"||"0"||"1"|"BOILERWATE,FURNACE"||"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"20"|"0"|"System upgraded as part of the Library addition project"|"1"|"S"|"2008"|"30"|"0"|"System upgraded as part of the Library addition project"|"1"|"S"|"2008"|"30"|"0"|"System upgraded as part of the Library addition project"|"1"|"S"|"2008"|"30"|"0"|"System upgraded as part of the Library addition project"|"1"|"S"|"2008"|"30"|"0"|"System upgraded as part of the Library addition project"|"1"|"S"|"1996"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"0"||||"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"|"Emergency generator added as part of Library addition"|"1"|"1"|"0"|"All except automatic door openers"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,LIGHTING"|"WARMING"|"0"|"1"||"GOOD"||"0"|"S"|"1"|"Rucinski Hall Architecture"|"627 Maple Avenue Saratoga Springs,NY 12866"|"5185801905"|"ephall@nycap.rr.com"|"Ethan Hall"|"027041"|"I accept"|11/17/2010 11:51:36 AM| 17|"Glens Falls Comn SD"|"63091808"|"Wing Classroom Building"|"0005"|"11/02/2010"|"120 Lawrence Street"|"Glens Falls"|" 12801"|"ANNUAL"|"01/01/2011"|"1991"|"3990"|"1"|"1"|"1"|"DISTRICT"|"INSTRUCT"||"45"|"4,5,6"|"0"|"1"|"0"|"0"|"45"|"0"|||"4"|"3990"|"NONE"||"0"||||||||"0"||"0"|"MUN_UTILIT"|"S"|"1991"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1991"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1991"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT"|"S"|"2008"|"20"|"0"||"1"|"CONCRETE"|"S"|"2008"|"20"|"0"||"0"|"S"|"1989"|"20"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1991"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1991"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1991"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1991"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1991"|"20"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1991"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1991"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"Y"|"1991"|"20"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1991"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1991"|"20"|"0"||"1"|"IRON"|"S"|"1991"|"20"|"0"||"0"|||||"0"||"1"|"S"|"1991"|"20"|"0"||"0"||"0"|"BOILERWATE"||"S"|"1996"|"20"|"0"||"0"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"0"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"S"|"1"|"Rucinski Hall Architecture"|"627 Maple Ave Saratoga Springs NY 12866"|"518-580-1905"|"cphall@nycap.rr.com"|"Ethan P Hall"|"027041"|"I ACCEPT"|11/17/2010 2:20:51 PM| 19|"Valley Stream 13 UFSD"|"28021302"|"Howell Road School"|"0002"|"03/03/2010"|"1475 Howell Road"|"Valley Stream"|" 11580"|"ANNUAL"|"05/01/2010"|"1951"|"67,760"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"580"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"580"|"0"|"0"|||"34"|"24,765"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"6,000"|"S"|"1990"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1949"|"5"|"0"|"Has RPZ"|"1"|"MUN_UTILIT"|"S"|"1949"|"5"|"0"||"1"|"S"|"1949"|"5"|"75,000"|"Upgrade gas service for dual fuel capability"|"1"|"UTIL"|"BELOW"|"S"|"2000"|"40"|"0"||"1"|"S"|"1951"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1951"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1980"|"5"|"53,000"|"Repair and sealcoat all asphalt play areas & between building wings."|"1"|"CONCRETE"|"S"|"1980"|"10"|"0"||"1"|"S"|"1951"|"10"|"0"||"1"|"S"|"1951"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1951"|"15"|"16000"|"Minor foundation repair west side and repair over boiler room door."|"1"|"S"|"1951"|"15"|"0"||"1"|"S"|"1951"|"15"|"10,000"|"Repair masonry wall area in boiler room beneath windows."|"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"S"|"U"|"1951"|"5"|"85,000"|"Replace/add closers throughout building, replace all locksets with levers, replace 2 pair gym doors, add M.H.O's on security doors and other misc. hardware work."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"40"|"35,000"|"Provide lightning protection"|"1"|"S"|"2003"|"13"|"45,000"|"Provide additional site security lighting in back corner of parking area where LIPA light removed, provide small theatrical dimming/lighting system on stage area. Repair/replace exterior security lighting controls for fixtures on during daytime hours."|"1"|"1"|"S"|"1980"|"5"|"195,000"|"Replace PA/intercom system with handset type system, provide wireless clock system."|"0"||||"0"||"1"|"COMMON"|"S"|"1951"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"10"|"390,000"|"Replace remaining VAT throughout building."|"1"|"COMMON"|"S"|"1951"|"10"|"0"||"1"|"COMMON"|"S"|"1951"|"10"|"0"||"SLABGRADE,OTHER"|"Reinforced concrete slab over crawlspace"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1951"|"15"|"0.00"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1951"|"15"|"15,000"|"Reconstruct building masonry beneath window in courtyard. Paint flagpole."|"1"|"MASONRY"|"S"|"1951"|"5"|"15,000"|"Rebuild upper 6' of chimney."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1980"|"5"|"35,500"|"Replace main entry door assembly, 2 other exterior doorway assemblies, and boiler room door."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"10"|"15,000"|"Replace cracked and hazed glazing."|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"2007"|"15"|"7,500"|"Paint soffits & fascia. Partial roof replacement project summer 2010 will complete phased roofing plan."|"0"|||||"0"||"1"|"COPPER"|"S"|"1949"|"5"|"65,000"|"Replace original non-functional gate valves."|"1"|"IRON"|"S"|"1949"|"5"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"15"|"5,000"|"Remove abandoned domestic hot water storage tank."|"1"|"S"|"1949"|"5"|"42,500"|"Provide sensing type faucets in all gang bathroom areas, remove sink mounted CR drinking fountains and provide a separate basin."|"0"||"1"|"BOILERSTEA"||"S"|"1949"|"5"|"750,000"|"Replace three original H.B. Smith steam boilers, consider an EPC. Reopen boiler room FAI louver and provide motorized damper."|"1"|"S"|"1949"|"5"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"1949"|"5"|"120,000"|"Refurbish all AHU and UV fresh air intake dampers, re-open relief air path in classroom doors."|"1"|"S"|"1949"|"5"|"75,000"|"Replace condensate receiver."|"1"|"S"|"1949"|"5"|"0"||"1"|"S"|"1949"|"5"|"75,000"|"Tie exhaust fans to day/night system, provide DDC head end for automatic temperature control including proper day/night operation."|"1"|"S"|"2000"|"5"|"160,000"|"Provide new ADA compliant smoke/fire detection system."|"1"|"S"|"2000"|"5"|"0"|"See item above"|"1"|"S"|"2004"|"2004"|"0"||"1"|"S"|"2003"|"13"|"0"||"0"||||"0"||"1"|"0"|"80,000"|"Reconstruct two gang toilet rooms for HCA"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"2,364,500"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 East Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I accept"|11/17/2010 3:45:35 PM| 21|"BOCES Wayne-Finger Lakes"|"43900000"|"Center for Experietial Learning"|"0002"|"09/23/2010"|"3501 County Road 20"|"Stanley"|" 14561"|"ANNUAL"|"08/01/2011"|"1970"|"12300"|"1"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"43"|"9,10,11,12"|"0"|"0"|"0"|"43"|"0"|"0"|||"5"|"6000"|"ADMIN,COMPROOM,MULTIPURPO,REMEDIAL,RSRCEROOM"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"25"|"0"||"1"|"SITESEPT"|"S"|"1993"|"40"|"0"||"1"|"S"|"1970"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"20"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"15"|"0"||"1"|"CONCRETE"|"S"|"2004"|"30"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"45"|"0"||"1"|"S"|"1970"|"40"|"0"||"1"|"S"|"2003"|"40"|"0"||"1"|"S"|"1993"|"5"|"0"||"1"|"S"|"1993"|"5"|"0"||"1"|"S"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"1"|"S"|"1993"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1993"|"1"|"60000"||"1"|"COMMON"|"S"|"1993"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"45"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"40"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"20"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2008"|"10"|"0"||"1"|"IRON,PVC"|"S"|"1970"|"5"|"0"||"1"|"ELECTRIC"|"S"|"2003"|"10"|"0"||"1"|"S"|"1970"|"5"|"0"||"0"||"1"|"OTHER"||"S"|"1971"|"5"|"0"||"1"|"S"|"2005"|"40"|"0"||"1"|"E"|"2006"|"30"|"0"||"1"|"S"|"2006"|"5"|"0"||"1"|"S"|"1971"|"5"|"0"||"1"|"S"|"1990"|"25"|"0"||"1"|"S"|"1971"|"5"|"0"||"1"|"S"|"1986"|"10"|"0"||"1"|"S"|"1998"|"13"|"0"||"0"||||"0"||"1"|"S"|"1970"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"1"|"1"|"1"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"339300"|"S"|"0"|"Beardsley Design Associates"|"64 South Street"|"315-253-7301"|"bda@beardsley.com"|"Steven F. Moulin"|"021568"|"I ACCEPT"|11/17/2010 4:24:20 PM| 22|"Valley Stream 13 UFSD"|"28021302"|"James A Dever School"|"0001"|"03/03/2010"|"585 N Corona Ave"|"Valley Stream"|" 11580"|"ANNUAL"|"05/01/2010"|"1949"|"65,101"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"505"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"505"|"0"|"0"|||"34"|"20,216"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"6,000"|"S"|"1990"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1949"|"5"|"0"|"Has RPZ"|"1"|"MUN_UTILIT"|"S"|"1949"|"5"|"0"||"1"|"S"|"1949"|"5"|"75,000"|"Upgrade gas service for dual fuel boiler capability."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"38"|"0"||"1"|"S"|"1949"|"15"|"0"||"0"||||"0"||"1"|"S"|"1949"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1949"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1989"|"5"|"175,000"|"Repair/overlay north lot & seal east play area. Minor repair south lot."|"1"|"CONCRETE,ASPHALT"|"U"|"1989"|"5"|"22,500"|"Replace settled asphalt sidewalk extensions with concrete."|"1"|"S"|"1949"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1949"|"15"|"0"||"1"|"S"|"1949"|"15"|"0"||"1"|"U"|"1949"|"15"|"50,000"|"Remove cross corridor doors near business office - dead end. Re-build wood door frame storage within gym with non-combustible construction."|"1"|"S"|"1949"|"10"|"0"||"0"||||"0"||"1"|"S"|"U"|"1949"|"5"|"85,000"|"Replace/add closers throughout building, replace all locksets with levers, add exit devices to gym doors, replace 3 pair auditorium doors, add M.H.O.'s on servery doors and other misc. hardware work."|"1"|"S"|"1949"|"15"|"5,000"|"Replace railings at interior ramp."|"0"||||"0"|"No elevator to 2nd floor, but only interchangeable classrooms."|"1"|"1"|"S"|"1999"|"39"|"35,000"|"Provide lightning protection system."|"1"|"S"|"2003"|"13"|"32,500"|"Provide small theatrical dimming/lighting system back on stage."|"1"|"1"|"S"|"1980"|"5"|"232,500"|"Replace PA/intercom system with handset type system, provide new auditorium sound system, provide 3 security cameras at rear of building, provide wireless clock system."|"0"||||"0"||"1"|"COMMON"|"S"|"1949"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"10"|"300,000"|"Replace remaining VAT throughout building."|"1"|"COMMON"|"S"|"1949"|"10"|"0"||"1"|"COMMON"|"S"|"1949"|"10"|"0"||"SLABGRADE,OTHER"|"Reinforced concrete slab over crawlspace"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1949"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1949"|"15"|"110,000"|"Tuckpoint cafeteria wall, north wall CR 102, masonry reconstruction at weatherhead, N/W corner 2nd floor, N/E corner lower wing, and other misc. work."|"1"|"MASONRY"|"S"|"1949"|"5"|"42,000"|"Rebuild upper 18' of chimney."|"1"|"MASONRY"|"S"|"1949"|"15"|"0"||"U"|"U"|"0"|"1"|"2004"|"5"|"67,500"|"Replace interior vestibule assembly near main office, 6 other exterior doorway assemblies and boiler room exterior door."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"10"|"75,000"|"Replace cracked and hazed glazing."|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"15"|"25,000"|"Oldest section approximately 15 years old. Paint soffits."|"0"|||||"0"||"1"|"COPPER"|"S"|"1949"|"5"|"65,000"|"Replace original non-functional gate valves."|"1"|"IRON"|"S"|"1949"|"5"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"19"|"0"||"1"|"S"|"1949"|"5"|"12,500"|"Provide sensing type faucets in all gang bathroom areas."|"0"||"1"|"BOILERSTEA"||"S"|"1949"|"5"|"570,000"|"Replace 2 original HB Smith steam boilers, consider an EPC."|"1"|"S"|"1980"|"5"|"0"||"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1949"|"5"|"140,000"|"Refurbish all AHU's and UV, fresh air intak dampers, verify proper relief air path in corridors, provide AHU connection for office in Business Office."|"1"|"S"|"1949"|"5"|"150,000"|"Replace condensate receiver."|"1"|"S"|"1949"|"5"|"0"||"1"|"S"|"1949"|"5"|"75,000"|"Tie exhaust fans to day/night system, provide DDC head end for automatic control including proper day/night operation."|"1"|"S"|"1999"|"5"|"160,000"|"Provide new ADA compliant smoke/fire detection system."|"1"|"S"|"1999"|"5"|"0"|"See item above"|"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2003"|"13"|"0"||"0"||||"0"||"1"|"0"|"80,000"|"Reconstruct two gang toilet rooms for HCA"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"1"|"0"|"0"|"GOOD"||"2,589,500"|"S"|"0"|"BBS Architects and Engineer, P.C."|"244 East Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I ACCEPT"|11/17/2010 4:32:30 PM| 24|"Commack USFD"|"58041003"|"BURR INTERMEDIATE SCHOOL"|"0035"|"02/16/2010"|"BURR ROAD "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1972"|"156,243"|"2"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"1030"|"6,7,8"|"0"|"1"|"0"|"1030"|"0"|"0"|||"44"|"36355"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB"||"1"|"0"|"0"|"1"|"15000"|"S"|"2004"|"44"|"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"19"|"0"||"1"|"SITESEPT"|"S"|"1972"|"19"|"0"||"1"|"S"|"2004"|"47"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1972"|"13"|"0"||"1"|"S"|"2004"|"44"|"0"||"0"||||"0"||"1"|"S"|"2004"|"44"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"24"|"0"||"1"|"CONCRETE"|"S"|"1972"|"7"|"0"||"1"|"S"|"2002"|"7"|"0"||"1"|"S"|"2003"|"19"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"29"|"0"||"0"||||"0"||"1"|"S"|"1972"|"29"|"0"||"1"|"S"|"1972"|"5"|"0"||"0"|"S"|"1972"|"4"|"0"||"1"|"S"|"S"|"1972"|"6"|"0"||"1"|"S"|"1972"|"14"|"0"||"1"|"S"|"1972"|"9"|"0"||"1"|"1"|"S"|"1972"|"13"|"0"||"1"|"U"|"1972"|"1"|"170000"|"Replace aging fixtures"|"1"|"1"|"S"|"1995"|"4"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1988"|"4"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1988"|"14"|"0"||"1"|"COMMON"|"S"|"1972"|"14"|"0"||"1"|"COMMON"|"S"|"1972"|"14"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1972"|"24"|"0"||"MASONRY"|"0"|"1"|"Rusted lintels "|"1"|"0"|"0"|"1"|"1"||"U"|"1972"|"1"|"50000"|"Clean rust off steel lintels and paint or replace depending on condition after rust comes off."|"1"|"MASONRY,METAL"|"S"|"1972"|"9"|"0"||"1"|"MASONRY"|"U"|"1972"|"1"|"5000"|"More destructive investigation is needed to determine if there is water infiltration in the parapets."|"S"|"S"|"0"|"1"|"2000"|"4"|"0"||"1"|"S"|"1972"|"19"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2002"|"4"|"150000"|"Replace the rest of the windows which were not replaced in 2002."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"1"|"1"|"1"|"Joint alongside parapets appears to be leaking."|"U"|"1980"|"1"|"450000"|"Replace roofing installing it over new tapered roof insulation."|"1"|"PLASTIC"|"S"|"1972"|"5"|"0"||"1"|"COPPER"|"S"|"1972"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1972"|"15"|"0"||"1"|"OIL,NAT_GAS"|"S"|"2004"|"7"|"0"||"1"|"S"|"1972"|"4"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2004"|"47"|"0"||"1"|"E"|"2004"|"47"|"0"||"1"|"S"|"1991"|"19"|"0"||"1"|"U"|"1972"|"1"|"200000"|"Replace 4 rooftop units and upgrade roof fans."|"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"0"|"U"|"2004"|"1"|"7500"|"Provide 3-way valve and compressor for new wing."|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"U"|"1972"|"1972"|"10000"|"Upgrade or replace Ansul System in Kitchen hood."|"1"|"U"|"1972"|"1"|"30000"|"Upgrade systems in stairways and elsewhere as needed."|"1"|"S"|"1972"|"9"|"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"GOOD"||"$ 1,222,500"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111 - Suite 200"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|11/17/2010 6:29:13 PM| 28|"Brasher Falls CSD"|"51010104"|"Elementary School"|"0005"|"08/18/2010"|"GEORGE STREET "|"BRASHER FALLS "|" 13613"|"ANNUAL"|"01/01/2011"|"1964"|"73228"|"1"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"425"|"Pre-K,K,1,2,3,4"|"0"|"1"|"0"|"425"|"0"|"0"|||"22"|"17779"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL"||"1"|"1"|"275"|"0"|"0"|"S"|"2006"|"15"|"0"|"Unable to determine year of last major reconstruct/replacement"|"1"|"WELL"|"S"|"2006"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"25"|"0"||"1"|"S"|"2006"|"25"|"0"||"1"|"UTIL,SELF"|"BELOW"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"|"Need to continuoously clean drainage swales"|"1"|"S"|"2009"|"2"|"5000"|"Catch basin located in courtyard has bermed earth around it,needs to be re-graded to allow proper drainage. Continuously clean covers & sumps."|"1"|"S"|"2009"|"15"|"0"||"1"|"SURFACEH2O,ONSITE"||"1"|"S"|"2009"|"10"|"0"|"Need to continuously clean overgrowth at the outfall and keep clear"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"3"|"68322"|"Replace sections of asphalt & base where it is severely cracked. Provide new sealant on remaining portions of asphalt parking areas."|"1"|"CONCRETE"|"S"|"2006"|"5"|"5758"|"Replace sections of severely deteriorated sidewalks. Replace caulk in joints."|"1"|"S"|"2002"|"15"|"0"|"Unable to determine year of last reconstruction/replacement"|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"1"|"0"|"0"|"0"|"S"|"2006"|"5"|"15500"|"Several areas where the foundation has cracked at building corners."|"1"|"S"|"2006"|"25"|"0"||"1"|"S"|"2006"|"5"|"11475"|"Masonry walls in the pool area are peeling and need to be repainted"|"1"|"S"|"2009"|"3"|"7096"|"Replace ceiling located in the pool locker rooms"|"1"|"U"|"1967"|"2"|"25000"|"The pool locker room lockers are rusting, replace with a phenolic locker"|"1"|"S"|"S"|"2010"|"20"|"35500"|"Replace wire glass with rated safety glazing, add door between gym and cafeteria to allow separate smoke exiting from gym"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2006"|"5"|"50000"|"1998 and newer panels in good condition, 1965 panels are in need of replacement, missing arc flash stickers"|"1"|"S"|"2006"|"5"|"20000"|"Majority of lights are T8 ballasts and in good condition. Gymnasium lighting is T12 and should be replaced with T8"|"1"|"1"|"S"|"2008"|"5"|"15000"|"P/A and clocks are older but in good working condition, should replace in 5 years"|"1"|"U"|"2000"|"3"|"289000"|"Replace pool filters, dehumidification system (including ductwork) & heat exchanger"|"1"|"INSTRUCT,COMMON"|"S"|"2006"|"8"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"5"|"3500"|"There appears to be VAT in 2 storage rooms, although sound, should be removed & replaced with VCT"|"1"|"COMMON"|"S"|"2009"|"3"|"122000"|"The pool tile is in need of re-grouting. Replace damaged/stained tile on pool deck"|"1"|"COMMON"|"S"|"2006"|"20"|"0"|"Periodic re-finishing will be required"|"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete structural slab on concrete beams"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2006"|"35"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"S"|"2006"|"4"|"44950"|"Repoint masonry in several areas due to settlement cracks. Scrape and paint steel lintels."|"1"|"MASONRY"|"S"|"2009"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"4"|"23333"|"Pool roof steel starting to rust, scrape and paint with epoxy paint"|"1"|"PLASTIC"|"S"|"2009"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1967"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1967"|"10"|"0"||"1"|"OIL,ELECTRIC"|"S"|"2006"|"10"|"0"||"1"|"S"|"2006"|"5"|"70000"|"The original fixtures are not low consumption fixtures as required by Code"|"0"||"1"|"BOILERWATE"||"S"|"2009"|"20"|"0"|"The building is served with hot water thru a heat exchanger from the high school boiler plant"|"0"||||"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"1964"|"0"|"250000"|"AHU's from original construction have passed their useful life expectancy of 25 years"|"1"|"S"|"2006"|"25"|"0"||"1"|"S"|"2006"|"25"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"E"|"2006"|"15"|"0"||"1"|"S"|"2006"|"2"|"3000"|"Missing heat detection in Kitchen and Life Skills"|"1"|"S"|"2006"|"2006"|"0"||"1"|"S"|"2006"|"5"|"35000"|"Exit lights are not all LED, should be upgradedfor energy efficiency. Corridors lacking some emergency lighting."|"1"|"S"|"1998"|"10"|"0"|"Co-gen located in the bus garage"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS,OTHER"|"Pool locker rooms"|"0"|||"1"|"1"|"1500"|"Replace stained ceiling tiles"|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"|"1"|"1"||"GOOD"||"1085433"|"S"|"0"|"Bernier, Carr - Associates, PC"|"327 Mullin Street, Watertown, NY 13601"|"315-782-8130"|"jjantzi@thebcgroup.com"|"Jason S. Jantzi, AIA"|"029165"|"I ACCEPT"|11/18/2010 11:17:17 AM| 31|"Valley Stream 13 UFSD"|"28021302"|"Wheeler Ave School"|"0003"|"03/04/2010"|"1 West Wheeler Ave"|"Valley Stream"|" 11580"|"ANNUAL"|"05/01/2010"|"1924"|"71,388"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"590"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"590"|"0"|"0"|||"26"|"21,943"|"ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"6,000"|"S"|"1990"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"5"|"0"|"Has RPZ"|"1"|"MUN_UTILIT"|"S"|"1955"|"5"|"0"||"1"|"S"|"1955"|"5"|"75,000"|"Upgrade gas service for dual fuel capability."|"1"|"UTIL"|"BELOW"|"S"|"2000"|"40"|"0"||"0"|"S"|"1924"|"15"|"0"||"0"||||"0"||"1"|"S"|"1924"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1924"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1980"|"5"|"350,000"|"Replace pavement on entire parking lot."|"1"|"CONCRETE"|"S"|"1980"|"10"|"0"||"1"|"S"|"1980"|"10"|"0"||"1"|"S"|"1989"|"10"|"40,000"|"N"|"Replace perimeter fencing; entire site."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1924"|"15"|"0"||"1"|"S"|"2002"|"15"|"28,000"|"Replace original roofing over basement stairwell. Support 2 roof drains in gymnasium tectum deck."|"1"|"S"|"1924"|"15"|"18,000"|"Remove & replace wall/doorway near gym to alleviate dead end condition. Fire seal pipes at custodial office."|"1"|"S"|"1955"|"5"|"0"||"0"||||"0"||"1"|"S"|"U"|"1955"|"5"|"140,000"|"Repl/add closers in bldg,repl locksets w/ levers&install missing doors on toilet rms.Add exit devices on various doors,add MHOs on servery drs.Repl bsmt door,2 pair gym drs,blr rm dr,strg. rm drs at main entry&other misc.hdwre work."|"1"|"S"|"1924"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1955"|"5"|"195,000"|"Replace original wiring in 1924 portion of building. Provide lightning protection system."|"1"|"S"|"2003"|"13"|"32,500"|"Provide small theatrical dimming/lighting system on stage."|"1"|"1"|"S"|"1955"|"5"|"195,000"|"Replace PA/intercom system with handset type system. Provide wireless clock system."|"0"||||"0"||"1"|"COMMON"|"S"|"1955"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1955"|"10"|"360,000"|"Replace remaining VAT"|"1"|"COMMON"|"S"|"1924"|"10"|"0"||"1"|"COMMON"|"S"|"1924"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1924"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1924"|"15"|"190,000"|"Repair masonry at auditorium, front right corner (full hgt), front lintels & parapets. Replace areaway lintels and other misc. masonry repairs. Paint areaway grates."|"1"|"MASONRY"|"S"|"1955"|"5"|"65,000"|"Rebuild chimney full height"|"1"|"MASONRY"|"S"|"1924"|"15"|"0"|"See item above"|"S"|"S"|"0"|"1"|"1924"|"10"|"50,000"|"Replace west stair/egress door assembly, 2 pair auditorium doors & 3 other pairs of exterior doors."|"1"|"S"|"1924"|"14"|"16,000"|"Add handrails at 4 locations."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"10"|"75,000"|"Replace cracked and hazed glazing. Replace all basement wood windows. Repair hardware on approx. 10 windows."|"WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"28,000"|"Replace original roofing over basement stairwell. Support 2 roof drains in gym tectum deck."|"0"|||||"0"||"1"|"COPPER"|"S"|"1955"|"5"|"65,000"|"Replace all original non-functioning gate valves."|"1"|"IRON"|"S"|"1955"|"5"|"0"||"1"|"OIL"|"S"|"1990"|"5"|"5,000"|"Remove abandoned domestic hot water storage tank."|"1"|"S"|"1955"|"5"|"42,500"|"Provide sensing type faucets in all gang bathroom areas, remove sink mounted CR drinking fountains and provide a separate basin."|"0"||"1"|"BOILERSTEA"||"S"|"1924"|"5"|"750,000"|"Replace 3 original Smith steam boilers, consider an EPC. Provide proper boiler room FAI louver with motorized damper."|"1"|"S"|"1924"|"5"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"1955"|"5"|"135,000"|"Refurbish all fresh air intake dampers, provide mechanical fresh air unit for social workers office, reopen CR relief air path."|"1"|"S"|"1955"|"5"|"85,000"|"Rebuild steam traps, repair auditorium heating zone."|"1"|"S"|"1924"|"5"|"0"||"1"|"S"|"1955"|"5"|"75,000"|"Tie exhaust fans to day/night system, provide DDC head end for automatic control including proper day/night operation."|"1"|"S"|"1999"|"5"|"175,000"|"Provide new ADA compliant smoke/fire detection system, tie hallway cross corridor doors into fire alarm system."|"1"|"S"|"1999"|"5"|"0"|"See item above"|"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2003"|"13"|"0"||"0"|"E"|||"0"||"0"|"0"|"1,190,000"|"Elevator, ramps, toilet reconstruction (3 pair gang toilets)"|"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"0"|"0"|"FAIR"|"Kindergarten housed at another school"|"4,352,000"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 East Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I ACCEPT"|11/18/2010 3:20:12 PM| 32|"Medina CSD"|"45080106"|"Clifford Wise Middle School"|"0003"|"11/4/09"|"1016 Gwinn Street"|"Medina"|" 14103"|"ANNUAL"|"7/1/11"|"1957"|"109180"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"413"|"6,7,8"|"0"|"1"|"1"|"413"|"0"|"0"|||"33"|"27852"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"1"|"500"|"0"|"0"|"E"|"2003"|"18"|"0"|"Above grade fuel tank with fence and containment installed in 2003."|"1"|"MUN_UTILIT"|"E"|"2003"|"30"|"0"|"New water service piping to building and backflow preventors installed in 2003"|"1"|"MUN_UTILIT"|"E"|"2003"|"30"|"0"|"Sanitary sewer main replaced from building to lift station in 2003."|"1"|"E"|"2009"|"30"|"0"|"Replaced gas service main in 2009. Meter/ regulator setting upgraded in 2003."|"1"|"UTIL"|"BELOW"|"E"|"2003"|"20"|"0"||"0"||||"0"||"1"|"E"|"2003"|"30"|"0"|"No reported issues."|"1"|"E"|"2003"|"30"|"0"|"No reported issues."|"1"|"S"|"1991"|"20"|"0"|"No reported issues."|"1"|"MUNI"||"0"|"S"|"1991"|"20"|"0"|"No reported issues."|"0"||||"0"||"1"|"S"|"2003"|"15"|"0"|"Retention basin reformed in 2003."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"20"|"600235"|"Replace section of roadway adjacent to the cafeteria leading up toward High School."|"1"|"CONCRETE"|"S"|"2009"|"20"|"0"|"Partial sidewalks replaced in 2009."|"0"||||"0"||"0"|"S"|||"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1957"|"15"|"286000"|"Provide crawl space drainage."|"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2009"|"25"|"0"|"New ceramic tile, and wall pads in the gym in 2009. New acoustics in Band/Chorus rooms 2009."|"1"|"S"|"2009"|"3"|"45700"|"Replace 1x1 Zspline ceiling in Auditorium."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"S"|"2009"|"15"|"92092"|"Added new lever sets at corridor doors in 2009. Additional hardware upgrades required."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"10"|"0"|"Only main service entrance equipment replaced in 2003."|"1"|"E"|"2003"|"15"|"0"|"All interior lights replaced in 2003."|"1"|"1"|"S"|"2003"|"10"|"0"|"Gymnasium sound system replaced in 2009."|"1"|"E"|"2009"|"15"|"0"|"Sand filters replaced in 2003. New pool liner installed in 2009."|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"|"New carpet installed in Main Office and Auditorium in 2009."|"1"|"INSTRUCT"|"S"|"2003"|"20"|"2926"|"Replace VAT tile in Storage Room adjacent to Main Office."|"1"|"COMMON"|"S"|"2003"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1957"|"10"|"0"|"Wood Shop flooring should be considered for replacement in the future. The gym looks ok, but could use refinishing."|"SLABGRADE,OTHER"|"Structural Concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"1"|"0"|"0"|"0"||"S"|"2009"|"15"|"461604"|"Consider adding thru-wall flashing at 1st floor. Thru-wall flashing was added at all roof locations in 2009."|"1"|"MASONRY"|"S"|"2009"|"15"|"0"|"Repointing completed in 2009 (partial)."|"1"|"MASONRY"|"S"|"2003"|"25"|"0"||"S"|"S"|"1"|"1"|"2009"|"20"|"0"|"New security system was installed in 2009."|"1"|"S"|"2009"|"20"|"77000"|"Add new concrete ramp at southwest corner of building near cafeteria. Replace main entrance steps with a ramp system."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"20"|"0"|"Pool windows and Kalwall system replaced in 2009."|"OTHER"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"25"|"0"|"Entire building roof replace in 2009."|"1"|"PLASTIC"|"E"|"2009"|"20"|"0"||"1"|"COPPER"|"E"|"2003"|"25"|"0"|"Domestic water piping replaced with copper in 2003."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2009"|"30"|"0"|"Sanitary sewer piping at kitchen and 6" south main replaced in 2009. Replace at natatorium in next capital project."|"1"|"NAT_GAS"|"E"|"2009"|"15"|"0"|"Building water heaters and tanks installed in 2003. New kitchen water heater installed in 2009."|"1"|"S"|"2003"|"15"|"0"|"Mix of 1957 annd newer fixtures. No reported issues."|"0"||"1"|"BOILERWATE"||"S"|"2003"|"20"|"0"|"No reported issues."|"1"|"S"|"2003"|"25"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"0"|"New autitorium rooftop AHU installed in 2009."|"1"|"S"|"2003"|"1"|"350000"|"Replace pool dehumidification system and associated ductwork."|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"187000"|"Update relief air and exhaust systems for art and science classrooms."|"1"|"S"|"2003"|"10"|"0"|"No reported issues."|"1"|"S"|"2003"|"10"|"20000"|"Extend fire alarm into non-compliant areas."|"1"|"S"|"2003"|"10"|"0"||"1"|"E"|"2009"|"2009"|"0"|"Kitchen hood fire supression system upgraded in 2009."|"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"1998"|"10"|"0"|"No reported issues."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"||"Areas of dormant mold were discovered in 2003. The areas were sealed with a self stick foil faced scrim. The district continues to monitor the scrim to ensure it remains sealed."|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"2186051"|"S"|"1"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Willliamsville New York, 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/18/2010 3:56:44 PM| 34|"Valley Stream 13 UFSD"|"28021302"|"Willow Road School"|"0004"|"03/04/2010"|"880 Catalpa Drive"|"Franklin Square"|" 11010"|"ANNUAL"|"05/01/2010"|"1955"|"69,699"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"494"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"494"|"0"|"0"|||"34"|"22,625"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"6,000"|"S"|"1990"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1951"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1951"|"5"|"0"||"1"|"S"|"1951"|"5"|"75,000"|"Upgrade gas service for dual fuel boiler capability."|"1"|"UTIL"|"BELOW"|"S"|"1951"|"5"|"0"||"1"|"S"|"1955"|"15"|"0"||"0"||||"0"||"1"|"S"|"1955"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1988"|"5"|"245,000"|"Repair/overlay parking lot and east play area. Replace sidewalk & pavement on north side of building."|"1"|"CONCRETE,ASPHALT"|"S"|"1998"|"10"|"0"|"See item above"|"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1955"|"10"|"90,000"|"N"|"Replace 2 backstops and fencing around ballfields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1955"|"15"|"2,500"|"Repair foundation at S/W corner."|"1"|"S"|"1955"|"15"|"0"||"1"|"S"|"1955"|"15"|"0"||"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"0"|"S"|"U"|"1955"|"5"|"90,000"|"Replace/add closers throughout building, replace all locksets with levers, add exit devices on general purpose room, replace 2 pair gym doors, add HMOs on servery doors and other misc. hardware work."|"1"|"S"|"1955"|"15"|"0"||"0"||||"0"|"No elevator to 2nd floor, but only interchangeable classrooms."|"1"|"1"|"S"|"1955"|"5"|"45,000"|"Provide lightning protection system, provide electric hand dryers in boys and girls bathrooms."|"1"|"S"|"2003"|"13"|"33,500"|"Provide small theatrical lighting/dimming system on stage, replace broken lens on rear exterior security light fixture."|"1"|"1"|"S"|"1980"|"5"|"195,000"|"Replace PA/intercom system with handset type system, provide wireless clock system."|"0"||||"0"||"1"|"COMMON"|"S"|"1988"|"10"|"0"||"0"|"INSTRUCT,COMMON"|"S"|"1955"|"10"|"650,000"|"Replace remaining VAT throughout building."|"1"|"COMMON"|"S"|"1955"|"10"|"0"||"1"|"COMMON"|"S"|"1955"|"10"|"0"||"SLABGRADE,OTHER"|"Reinforced concrete slab over crawlspace"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1955"|"15"|"2,500"|"Repair foundation at gym S/W corner."|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1955"|"15"|"25,000"|"Repair masonry at S/W gym corner and other misc. repairs. Pain flagpole."|"1"|"MASONRY"|"S"|"1955"|"5"|"20,000"|"Rebuild upper 8 feet of chimney."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1955"|"5"|"48,000"|"Replace main entry door assembly and 4 other exterior door assemblies."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"10"|"15,000"|"Replace cracked and hazed glazing."|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"5"|"750,000"|"Replace remaining old roof areas. Paint soffits, partial roofing projects scheduled for summer 2010 and 2011. Will still have one remaining phase."|"0"|||||"0"||"1"|"COPPER"|"S"|"1955"|"5"|"65,000"|"Replace original non-functional gate valves."|"1"|"IRON"|"S"|"1955"|"5"|"0"||"1"|"OIL"|"S"|"1998"|"8"|"5,000"|"Remove abandoned domestic hot water storage tank."|"1"|"S"|"1955"|"5"|"42,500"|"Provide sending type faucets in all gang bathroom areas, remove sink mounted CR drinking fountains and provide a separate basin."|"0"||"1"|"BOILERSTEA"||"S"|"1951"|"5"|"750,000"|"Replace 3 original HB Smith steam boilers, consider an EPC. Reopen boiler room fresh air intake louver, and provide motorized damper."|"1"|"S"|"1951"|"5"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"1955"|"5"|"120,000"|"Refurbish all fresh air intake dampers, reopen proper relief air path from classrooms."|"1"|"S"|"1955"|"5"|"150,000"|"Replace condensate receiver, rebuild steam traps."|"0"||||"0"||"1"|"S"|"1955"|"5"|"75,000"|"Tie exhaust fans to day/night system, provide DDC head end for automatic temperature control including proper day/night operation."|"1"|"S"|"1999"|"5"|"160,000"|"Provide new ADA compliant smoke/fire detection system."|"1"|"S"|"1999"|"5"|"0"|"See item above."|"1"|"S"|"2004"|"2004"|"0"||"0"|"S"|"2003"|"13"|"0"||"0"||||"0"||"1"|"0"|"80,000"|"Reconstruct 2 gang toilet rooms for HCA"|"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"1"|"0"|"0"|"GOOD"||"3,731,500"|"S"|"0"|"BBS Architects and Engineer PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I ACCEPT"|11/18/2010 4:51:45 PM| 35|"Commack USFD"|"58041003"|"WOOD PARK PRIMARY SCHOOL"|"0004"|"03/30/2011"|"CEDAR RD "|"EAST NORTHPORT "|" 11725"|"ANNUAL"|"05/01/2011"|"1960"|"48000"|"1"|"2"|"1"|"LSD_NDE"|"INSTRUCT,OTHER"|"Leased to Jewish Acad/SCOPE program"|"75"|"Pre-K,K,1,2"|"0"|"1"|"0"|"75"|"0"|"0"|||"27"|"21300"|"ADMIN,CAFE,GYM,KITCHEN,LIBBRARY,MULTIPURPO,PREK"||"1"|"0"|"0"|"1"|"10000"|"S"|"2009"|"20"|"0"|"Fuel tank was replaced."|"1"|"MUN_UTILIT"|"S"|"1960"|"15"|"0"||"1"|"SITESEPT"|"S"|"1960"|"15"|"0"||"1"|"S"|"2003"|"41"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"1"|"25000"|"Upgrade primary and secondary cables."|"1"|"S"|"1960"|"5"|"0"||"0"||||"0"||"1"|"S"|"1960"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1960"|"1"|"0"||"1"|"CONCRETE"|"S"|"2008"|"5"|"0"||"1"|"S"|"2000"|"25"|"0"||"1"|"S"|"1960"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"25"|"0"|"Some cracks in Gymnasium are being monitored."|"1"|"S"|"1960"|"25"|"0"||"1"|"U"|"1960"|"1"|"250000"|"Concealed type ceilings need to be replaced with suspended type of ceilings for access to roof structure."|"1"|"U"|"1960"|"1"|"80000"|"Replace lockers as needed."|"1"|"U"|"U"|"1960"|"1"|"75000"|"Replace doors and hardware as needed."|"1"|"S"|"1960"|"15"|"0"|"Concrete stair to Boiler Room."|"0"||||"0"||"1"|"1"|"U"|"1960"|"1"|"150000"|"Replace switchboards and panelboards."|"1"|"U"|"1960"|"1"|"120000"|"Replace fixtures in Corridors and Classrooms as needed."|"1"|"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1960"|"2"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1960"|"2"|"0"||"1"|"COMMON"|"S"|"1960"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"U"|"1960"|"1"|"75000"|"Repointing needed and replacement of failing expansion joints."|"1"|"MASONRY"|"U"|"1960"|"1"|"20000"|"Repoint brick and replace flashing and bricks at base."|"0"|||||"0"||"U"|"S"|"0"|"1"|"1960"|"5"|"0"||"1"|"S"|"1960"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1960"|"1"|"300000"|"Replace all original windows."|"WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Water penetration from roof in East Corridor"|"S"|"2000"|"10"|"0"||"1"|"PLASTIC"|"S"|"1960"|"10"|"0"||"1"|"COPPER"|"S"|"1960"|"5"|"0"||"1"|"IRON"|"S"|"1960"|"5"|"0"||"0"|||||"0"||"1"|"S"|"1960"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"0"||||"0"||"1"|"U"|"1960"|"1"|"60000"|"Repair or replace aging roof fans."|"1"|"U"|"1960"|"1"|"25000"|"Replace original ciculating pumps."|"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2003"|"13"|"0"||"1"|"S"|"2003"|"13"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 1,240,000"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111 - Suite 200, Hauppauge, NY"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|11/18/2010 6:51:50 PM| 39|"Glens Falls Comn SD"|"63091808"|"New Bus Garage"|"4006"|"11/2/2010"|"74 McDonald Street"|"Glens Falls"|"12801"|"ANNUAL"|"01/01/2011"|"1995"|"1020"|"1"|"1"|"1"|"DISTRICT"|"OTHER"|"Bus Storage"|"0"||"0"|"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"20"|"0"||"1"|"OTHER"|"S"|"1995"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1995"|"20"|"0"||"1"|"CONCRETE"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"0"||||"0"||"1"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"||||"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"1"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1995"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1995"|"20"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1995"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1995"|"20"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1995"|"20"|"0"|"hose bib connection only"|"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1995"|"20"|"0"|"there are 2 heat sensors; one over each bay"|"0"||||"0"||"0"||||"0"||"1"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"GOOD"||"0"|"S"|"1"|"Rucinski Hall Architecture"|"627 Maple Ave., Saratoga Springs12866"|"5185801905"|"ephall@nycap.rr.com"|"Ethan Hall"|"027041"|"I accept"|11/19/2010 10:17:24 AM| 40|"Island Trees UFSD"|"28022603"|"Geneva N. Gallow School"|"0005"|"08/31/2010"|"74 Farmedge Road"|"LEVITTOWN "|" 11756"|"ANNUAL"|"04/01/2010"|"1955"|"40,200"|"2"|"4"|"0"|"DISTRICT"|"OTHER_ORG"||"0"|"UNGRD"||"0"|"1"|"0"|"0"|"0"|||"23"|"19,320"|"CAFE,GYM,HLTHSUITE,KITCHEN,MULTIPURPO,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1980"|"30"|"0"|"Newer double walled fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1980"|"20"|"0"|"Has RPZ devices."|"1"|"MUN_UTILIT"|"S"|"1975"|"35"|"0"||"1"|"S"|"1955"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"1"|"S"|"1955"|"20"|"0"||"0"||||"0"||"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1989"|"0"|"240,000"|"Repave west lot. Crackfill & seat north lot."|"1"|"CONCRETE"|"S"|"2000"|"10"|"20,000"|"Replace approx. 12 damaged flags various areas. Replace asphalt walkway outside north wing."|"1"|"S"|"1987"|"5"|"0"||"1"|"S"|"1955"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1955"|"15"|"7,500"|"Unclog drain and clean out areaway at former x-frame fault. Repair top of spalled areaway walls."|"1"|"S"|"1955"|"15"|"0"||"1"|"S"|"1955"|"15"|"25,000"|"Remove wood frame walls and rebuild with non-combustible construction at storage near BR switchgear. Construct new wall to enclose switchgear. Remove remaining overhead CMU at partially demolished wall in bmnt. Rebuild stairwell plexiglass wall."|"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1955"|"10"|"17,500"|"Replace 2 serving line doors for fire rating, and (3) pair gym doors. Provide ADA hardware where required."|"1"|"S"|"1955"|"10"|"0"||"1"|"S"|"1955"|"10"|"0"||"1"|"1"|"S"|"1955"|"10"|"100,000"|"Create dedicated switchgear room around existing switchgear. Replace existing panel interiors."|"1"|"S"|"1955"|"0"|"175,000"|"Replace incandescent lighting in basement. Replace T-12 lighting throughout building."|"1"|"1"|"S"|"1955"|"20"|"0"|"System relatively new and in good working order."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2010"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1955"|"10"|"4,500"|"Replace asbestos tile in gym storage."|"1"|"COMMON"|"S"|"1955"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"SLABGRADE,OTHER"|"One-way reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1955"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"0"|"1"|"0"||"S"|"1955"|"15"|"60,000"|"Reconstruct CMU beneath gym windows,repoint brick and reconstruct masonry & flashing at grilles in E. gym wall,reconstruct brick outside S.stairwell at approx. 16 UV lintels,crack near N.exit doors and other minor masonry recosntruction"|"1"|"MASONRY"|"S"|"1955"|"10"|"42,000"|"Repoint entire chimney and add S/S cap."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"20,000"|"Repair hinge on aluminum vestibule door, replace pair gym exit doors, boiler room door and pair of doors and sidelights opposite main entry with FRP aluminum."|"1"|"S"|"1955"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"15"|"0.00"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1955"|"20"|"0"|"Continue to monitor and maintain."|"1"|"IRON"|"S"|"1955"|"20"|"0"|"Continue to monitor and maintain."|"1"|"OIL"|"S"|"1990"|"0"|"20,000"|"Unit good working order, but at the end of its useful life."|"1"|"S"|"1955"|"0"|"50,000"|"Fixtures old, but in good condition. Replace hose bibs and drinking fountains. Continue to monitor and maintain."|"0"||"1"|"BOILERSTEA"||"E"|"2005"|"30"|"0"||"1"|"E"|"2005"|"30"|"0"|"Have double walled underground FOST, relatively new."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1955"|"0"|"800,000"|"Unit vents are working, but at the end of their useful life."|"1"|"S"|"1955"|"20"|"0"|"Continue to monitor and maintain."|"1"|"S"|"1955"|"0"|"100,000"|"Units in working order, but at the end of their useful life."|"1"|"S"|"1955"|"0"|"175,000"|"Replace pneumatic controls using DDC control system."|"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"S"|"1955"|"1955"|"0"|"Kitchen hood wet chemical fire suppression inspected annually."|"1"|"S"|"1955"|"10"|"15,000"|"Repplace using LED type with battery backup."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,INCANDESCE,OTHER"|"FAIR"|"Lighting old and inefficient. Recommend full replacement."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"|"Recommend updating temperature contrl system and unit ventilator replacement."|"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"WARMING"|"1"|"1"|"0"|"FAIR"||"1,871,500"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 East Main Street"|"631-475-0349"|"rettig@bbsarch.com"|"Joseph B. Rettig, AIA"|"032280"|"I ACCEPT"|11/19/2010 10:28:41 AM| 42|"Island Trees UFSD"|"28022603"|"Island Trees High School"|"0003"|"09/03/2010"|"59 STRAIGHT LANE "|"LEVITTOWN "|" 11756"|"ANNUAL"|"04/01/2011"|"1957"|"148,314"|"2"|"7"|"2"|"DISTRICT"|"INSTRUCT"||"873"|"9,10,11,12"|"0"|"1"|"1"|"873"|"0"|"0"|||"36"|"29,512"|"ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1957"|"30"|"0"|"Newer double walled fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1980"|"55"|"0"|"Has RPZ devices."|"1"|"MUN_UTILIT"|"S"|"1975"|"40"|"0"||"1"|"S"|"1957"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"25"|"0"||"1"|"U"|"1957"|"0"|"0"|"Under investigation along with items 33 & 36."|"0"||||"0"||"1"|"S"|"1957"|"0"|"0"|"See item 31"|"0"||||"0"||"0"|||||||"0"||"0"|"S"|"1957"|"0"|"See item 31"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1957"|"5"|"145,000"|"Repair, crackfill and seal east and south lots. Repair and overlay west lot."|"1"|"CONCRETE,ASPHALT"|"S"|"1957"|"10"|"175,000"|"Repave visitors bleacher area (in conjuction with items 31, 33, 36 and 43). Repave home bleacher area and connecting sidewalk and repair various broken concrete sidewalks ($10,000 allowance)."|"0"||||"0"||"1"|"U"|"1957"|"0"|"1,400,000"|"N"|"Complete running track replacement. Replace home and visitors side bleachers (1,000 capacity each)."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"15"|"10,000"|"Repair top of areaway walls, south and west sides of building."|"1"|"S"|"1957"|"15"|"0"||"1"|"S"|"1957"|"5"|"1,115,000"|"Complete library renovation. Complete home ec. renovation (127). Remove and rebuild combustible wall construction in basement."|"1"|"S"|"1957"|"10"|"110,000"|"Replace ceiling in 2nd floor corridor and custodial office."|"1"|"S"|"1957"|"10"|"0"||"0"|"U"|"U"|"1957"|"5"|"145,000"|"Replace all primary doors (those opening on to corridors approx. 125)."|"1"|"S"|"1957"|"15"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"1"|"S"|"2000"|"30"|"150,000"|"Replace existing panel interiors and breakers (for old branch panels)."|"1"|"S"|"1957"|"0"|"450,000"|"Replace all old T-8 modified egg crate style fixtures."|"1"|"1"|"S"|"1957"|"0"|"225,000"|"Owner maintains operation, but system is unreliable and in need of replacement."|"0"||||"0"||"0"|||||"0"||"0"|"INSTRUCT,COMMON"|"S"|"1957"|"10"|"385,000"|"Replace VAT throughout building (approx. 27,000 sf)."|"1"|"COMMON"|"S"|"1957"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"10"|"0"||"OTHER"|"One-way reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1957"|"10"|"165,000"|"Rpr.ext.balcony edges,brickatstair landing&N/Ecorner.Rbld.brick atS/Ecorner gym,audit.wall over roof,elev. penthouse.Rpr.lintel near OH dr.Rbld brick&repl.approx45ft 2nd flrN/Eside window lintel.Rbld brick spandrelS.side&other misc.mason rpr."|"1"|"MASONRY"|"S"|"1957"|"10"|"42,000"|"Repair and tuckpoint entire chimney. Provide S/S cap."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1957"|"0"|"128,500"|"Replace all exterior doors and frames."|"1"|"S"|"1957"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"15"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"16,500"|"Replace fan room roof hatch. Paint roof dunnage and duct supports."|"0"|||||"0"||"1"|"COPPER"|"S"|"1957"|"23"|"0"|"Continue to monitor and maintain."|"1"|"IRON"|"S"|"1957"|"23"|"0"|"Continue to monitor and maintain."|"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"Units in good working order."|"1"|"S"|"1957"|"0"|"50,000"|"Fixtures old, but in good condition. Some have been replaced. Cost shown for replacement of hose bibs & drinking fountains. Continue to monitor and maintain."|"1"|"CV"|"1"|"BOILERSTEA"||"E"|"2005"|"30"|"45,000"|"Repair old vacuum/condensate unit. Replace single swing barometric damper with double swing type, including spill switches."|"1"|"S"|"1957"|"20"|"50,000"|"Have double walled underground FOST, relatively new. Cost shown to provide gas service for main fuel."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1957"|"15"|"1,800,000"|"Repair auditorium AC system. Reinsulate and weatherproof all rooftop ductwork. Replace gym air handling units. Replace all classroom unit ventilators."|"1"|"S"|"1957"|"23"|"75,000"|"Continue to monitor and maintain. Cost shown to perform a complete steam trap replacement."|"1"|"S"|"1957"|"0"|"0"|"Continue to monitor and maintain."|"1"|"S"|"1957"|"0"|"250,000"|"Expand basic DDC control system to control all existing roof fans, new unit vents, all air handlers, auditorium AC and boiler plant."|"1"|"E"|"2009"|"29"|"0"||"1"|"E"|"2009"|"29"|"0"||"1"|"U"|"1957"|"1957"|"175,000"|"Provide correct kitchen hood systems with fire protection and proper make-up air equipment."|"1"|"S"|"1957"|"10"|"20,000"|"Replace various exit signs with LED type with battery backup. Add emergency lighting where applicable."|"0"||||"0"||"1"|"0"|"300,000"|"Fully renovate one boys and one girls toilet room on each floor."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"|"Lighting systems in good condition. Replace gym lights for better efficiency."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"|"Unit ventilators/controls are at the end of their useful life."|"0"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"GOOD"||"7,427,000"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 East Main Street"|"631-475-0349"|"rettig@bbsarch.com"|"Joseph B. Rettig, AIA"|"032280"|"I ACCEPT"|11/19/2010 11:41:41 AM| 44|"Island Trees UFSD"|"28022603"|"Island Trees Memorial Middle School"|"0004"|"09/01/2010"|"55 WANTAGH AVENUE "|"LEVITTOWN "|" 11756"|"ANNUAL"|"04/01/2011"|"1951"|"154,376"|"2"|"9"|"2"|"DISTRICT"|"INSTRUCT"||"800"|"5,6,7,8"|"0"|"1"|"1"|"800"|"0"|"0"|||"68"|"55,008"|"ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1951"|"30"|"0"|"New double walled fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1980"|"17"|"0"|"Has RPZ devices."|"1"|"MUN_UTILIT"|"S"|"1975"|"40"|"0"||"1"|"S"|"1951"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"1"|"S"|"1951"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1951"|"10"|"35,000"|"Abandon drywell next to oil tank (contamination suspected) and install 2 additional drywells in north lot (coordinate with item 40)."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1951"|"5"|"165,000"|"Replace east lob curbing along building and minor repair, cracfill and seal north and east lots."|"1"|"CONCRETE"|"S"|"1951"|"10"|"0"||"1"|"S"|"1951"|"5"|"65,500"|"Crackfill and seal asphalt play area. Demo existing and construct new playground on south side of building ($40,000 allowance)."|"1"|"S"|"1951"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1951"|"15"|"0"||"1"|"S"|"1951"|"15"|"0"||"1"|"S"|"1951"|"15"|"27,000"|"Remove wood frame walls in basement maintenance department and rebuild with non-combustible construction. Remove defunct casetwork from roomm 165 and patch flooring."|"1"|"S"|"1951"|"10"|"545,400"|"Replace 2nd floor corridor ceiling and lighting and in approximately 43 classrooms."|"1"|"S"|"1951"|"15"|"0"||"1"|"U"|"U"|"1951"|"5"|"140,000"|"Repl.approx. 2/3 of primary (corridor) doors. Remove&replace deadbolt HW at stage,fitness,main office&LR.Repl. knob lever hardware at mensADAatoilet. Install bottom rods on cafe doors,replace unrated cafe stage doors."|"1"|"S"|"1951"|"15"|"3,500"|"Repair loose wainscot tile at south stairwell."|"1"|"S"|"1951"|"15"|"0"||"1"|"1"|"S"|"1951"|"0"|"325,000"|"Replace existing panel interiors (for old branch panels). Replace switchgear and service."|"1"|"S"|"1951"|"5"|"300,000"|"Replace all old T-8 modified egg crate style fixtures. Replace merc. vapor fixtures in gym. Replace stage dimming system."|"1"|"1"|"S"|"2008"|"28"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1951"|"10"|"7,500"|"Replace VAT at room 158."|"1"|"INSTRUCT"|"S"|"1951"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"OTHER"|"One-way reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1951"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1951"|"10"|"445,000"|"ReplclstrylintNsidegym&8secE1stflrRbldbrickNsidegymtopofwallsaroundPHshiftedbrickbtwn142&144corners141&142portionofbricks147120sfwall250outide176&260outside102&N.sidecafelintelTPlimestonepnls&locationsofCMUlggymElastomeric lggym"|"1"|"MASONRY"|"S"|"1951"|"10"|"87,500"|"Remove upper 10' of chimney and replace stone cap. Demolish & cap unused foundry chimney."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"10"|"0"||"1"|"S"|"1951"|"15"|"0"||"0"|"S"|"1"|||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"15"|"200,000"|"Reset approx. 240 slate sills and cap all with aluminum. Replace yellowed plexiglass on east side of building."|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"6,000"|"Repaint roof ladders. Replace missing section of break metal soffit outside room 202."|"0"|||||"0"||"1"|"COPPER"|"S"|"1951"|"17"|"0"|"Continue to monitor and maintain."|"1"|"IRON"|"S"|"1951"|"17"|"0"|"Continue to monitor and maintain."|"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"Units in good working order."|"1"|"S"|"1951"|"2"|"75,000"|"Fixtures old, but ind good condition. Some have been replaced. Continue to monitor and maintain. Cost shown is for hose bib and drinking fountain replacement."|"1"|"CV"|"1"|"BOILERSTEA"||"E"|"2005"|"30"|"0"||"1"|"S"|"1951"|"30"|"0"|"Have double walled underground FOST, relatively new."|"1"|"S"|"2005"|"10"|"0"||"1"|"U"|"1951"|"0"|"1,650,000"|"Replace all unit ventilators. Systems at the end of their useful life."|"1"|"S"|"1951"|"17"|"0"|"Continue to monitor and maintain."|"1"|"S"|"1951"|"0"|"350,000"|"Replace all central station air handling equipment. (Gym/auditorium etc.)."|"1"|"S"|"1951"|"0"|"250,000"|"Expand basic DDC control system to control all new unit vents, air handlers, boiler plant and all exisiting exhaust fans."|"1"|"E"|"2009"|"29"|"0"||"1"|"E"|"2009"|"29"|"0"||"1"|"S"|"1951"|"1951"|"5,000"|"Kitchen hood fire suppression system-inspected annually. Good working order. Provide side wing for existing hood."|"1"|"S"|"1951"|"10"|"20,000"|"Replace various exit signs using LED type with battery backup. Add emergency lighting where appropriate."|"0"||||"0"||"1"|"0"|"340,000"|"Reconstruct one boys room and girls room each floor for accessibility as well as women's room by HPEA offices."|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"|"Lighting systems in good condition. Replace gym lights for better efficiency."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"POOR"|"Recommend updating temperature control system and full unit vent replacement."|"0"|"0"|"1"|"1"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"1"|"0"|"0"|"GOOD"||"5,092,400"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 East Main Street"|"631-475-0349"|"rettig@bbsarch.com"|"Joesph B. Rettig, AIA"|"032280"|"I ACCEPT"|11/19/2010 1:54:06 PM| 45|"Island Trees UFSD"|"28022603"|"J. Fred Sparke Elementary School"|"0002"|"09/03/2010"|"100 ROBIN PLACE"|"LEVITTOWN "|" 11756"|"ANNUAL"|"04/01/2010"|"1956"|"85,116"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"305"|"K,1,2,3,4"|"0"|"0"|"0"|"305"|"0"|"0"|||"28"|"25,856"|"CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,REMEDIAL,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1956"|"30"|"0"|"Newer double walled fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1980"|"21"|"0"|"Have RPZ devices."|"1"|"MUN_UTILIT"|"S"|"1975"|"35"|"0"||"1"|"S"|"1956"|"20"|"50,000"|"Provide gas service for main boiler fuel."|"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"1"|"S"|"1956"|"10"|"0"||"0"||||"0"||"1"|"S"|"1956"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1956"|"10"|"15,000"|"Add leaching pools to bus loop (in conjunction with item 40)."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1956"|"5"|"85,500"|"Repave bus loop."|"1"|"CONCRETE"|"S"|"1956"|"10"|"3,500"|"Replace approximately 4 flags broken sidewalk."|"1"|"S"|"1956"|"5"|"10,500"|"Crackfill and seal asphalt play area."|"1"|"S"|"1956"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"15"|"2,500"|"Repair corner of areaway wall at guardrail post."|"1"|"S"|"1956"|"15"|"0"||"1"|"S"|"1956"|"15"|"12,500"|"Remove wood frame construction at top of stair. Fire-stop various pipes and conduit in basement. Reglaze sliding window at office for Code compliance."|"1"|"S"|"1956"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1956"|"10"|"20,000"|"Repl.doors at gym (2) pair, cafetorium (2) pair, room 103, cafeteria storage.Repl. deadbolt at stage door and main office doors,add exit devices to corridor smoke doors.Add closers to serving line doors. Install ADA hardware at required locations"|"1"|"S"|"1956"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"10"|"75,000"|"Replace existing panel interiors and breakers (for old branch panels)."|"1"|"S"|"1956"|"10"|"300,000"|"Replace merc. vaport lighting in gym. Replace lighting in cafeteria. Repalce CR egg crate lighting. Replace some exterior light fixtures."|"1"|"1"|"S"|"1980"|"0"|"160,000"|"System old, but in good working order. Recommend replacement due to age."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1956"|"10"|"0"||"1"|"COMMON"|"S"|"1956"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"SLABGRADE,OTHER"|"One way reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1956"|"10"|"150,000"|"Reconupper corner of cafeCMU&brick.Rbld shiftedCMUin131&132.Rpr masonry in stage and add controljoints.Rpr bowing block&wall tile acrosscafe.Paintribbon windowlntls. Repl5sec.ribbon window lntls. Sawcutnew CJ&addtlmisc.masonry recon"|"1"|"MASONRY"|"S"|"1956"|"15"|"5,500"|"Repoint entire chimney and waterproof newly installed mortar cap."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"||"1"|"S"|"1956"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"N"|"1997"|"15"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1956"|"21"|"0"|"Continue to monitor and maintain"|"1"|"IRON"|"S"|"1956"|"21"|"0"|"Continue to monitor and maintain"|"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"Unit in good working order"|"1"|"S"|"1956"|"0"|"40,000"|"Fixtures old, but in good condition. Some have been replaced. Continue to monitor and maintain. Cost shown for replacement of hose bibs and drinking fountains."|"0"||"1"|"BOILERSTEA"||"E"|"2005"|"30"|"30,000"|"Replace existing older vacuum/condensate unit."|"1"|"S"|"1956"|"30"|"0"|"Have double walled underground FOST, relatively new. "|"1"|"S"|"2005"|"10"|"0"||"1"|"E"|"2008"|"28"|"0"||"1"|"S"|"1956"|"20"|"0"|"Continue to monitor and maintain"|"1"|"S"|"1956"|"0"|"60,000"|"Replace air handling equipment in the gym."|"1"|"S"|"2008"|"28"|"75,000"|"Expand DDC system to include exhaust fan contro/convector control."|"1"|"E"|"2008"|"28"|"0"||"1"|"E"|"2008"|"28"|"0"||"1"|"S"|"1956"|"1956"|"0"|"Kitchen hood fire suppression system-inspected annually."|"1"|"S"|"1956"|"10"|"15,000"|"Replace using LED type with battery backup. (Some currently being done)."|"0"||||"0"||"1"|"0"|"120,000"|"Reconstruct boys and girls toilet room for HCA accessibility"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"|"Lighting systems in good condition. Replace gym lights for better efficiency."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Recommend updating temperature control system"|"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"GOOD"||"1,230,000"|"S"|"0"|"BBS Architects and Engineer, P.C."|"244 East Main Street"|"631-475-0349"|"rettig@bbsarch.com"|"Joseph B. Rettig, AIA"|"032280"|"I ACCEPT"|11/19/2010 2:37:27 PM| 46|"Commack USFD"|"58041003"|"COMMACK HIGH SCHOOL"|"0008"|"03/29/2010"|"SCHOLAR LANE "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1961"|"357031"|"2"|"18"|"0"|"DISTRICT"|"INSTRUCT"||"2300"|"9,10,11,12"|"0"|"1"|"1"|"2300"|"120"|"0"|||"120"|"96000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"0"|"0"|"2"|"28000"|"S"|"2005"|"34"|"0"||"1"|"MUN_UTILIT"|"E"|"2005"|"43"|"0"||"1"|"SITESEPT"|"S"|"1961"|"15"|"0"||"0"|"S"|"2005"|"34"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2005"|"45"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"20"|"0"||"1"|"CONCRETE"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"S"|"1970"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"1961"|"5"|"0"||"1"|"U"|"U"|"1961"|"1"|"200000"|"Replace doors and hardware as needed."|"1"|"U"|"1961"|"1"|"30000"|"Provide intermediate handrails at 8'-0" wide stairs to comply with the Building Code of New York State, Section 1009.11.2."|"1"|"S"|"2004"|"25"|"0"||"1"|"1"|"S"|"2005"|"5"|"0"||"1"|"S"|"2009"|"10"|"0"|"Lighting fixtures were replaced."|"1"|"1"|"S"|"2009"|"10"|"0"|"Systems were replaced."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1972"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1972"|"10"|"0"||"1"|"COMMON"|"S"|"1972"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"Bad crack at exp. jt. outside of Boys Gym Corridor"|"U"|"2004"|"1"|"130000"|"Brick repointing and expansion joint repirs are required at original wing of the building and elsewhere as noted above."|"1"|"MASONRY"|"U"|"1961"|"25000"|"0"|"Repointing of the brick and extension of the chimney are needed."|"0"|||||"0"||"U"|"U"|"0"|"1"|"2004"|"1"|"110000"|"Replace 16 pairs of original doors."|"1"|"S"|"1961"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2004"|"1"|"120000"|"Replace old windows in Wing D and in Library Corridor."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"1"|"PLASTIC"|"S"|"1961"|"5"|"0"||"1"|"COPPER"|"S"|"2008"|"2"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"2"|"0"||"1"|"OIL"|"E"|"2010"|"20"|"0"|"Hot water tank was replaced."|"1"|"U"|"1996"|"1"|"40000"|"Replace remainign old fixtures as needed."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1985"|"15"|"0"||"1"|"S"|"1997"|"35"|"0"||"1"|"S"|"1997"|"35"|"0"||"1"|"U"|"1997"|"1"|"25000"|"Replace or repair foof fan units."|"1"|"U"|"1963"|"1"|"450000"|"Replace piping as needed and unit vents in Auxiliary Gym."|"1"|"S"|"1963"|"2"|"0"||"1"|"E"|"2005"|"34"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"||"0"|"E"|"2006"|"2006"|"0"||"1"|"S"|"2005"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"WARMING"|"0"|"1"||"GOOD"||"$ 1,130,000"|"U"|"1"|"Tagi A.Garbizu and Associates"|"501 Route 111-Suite 200, Hauppauge, NY"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|11/19/2010 3:00:54 PM| 47|"Brasher Falls CSD"|"51010104"|"Bus Garage"|"5002"|"10/06/2010"|"GEORGE STREET "|"BRASHER FALLS "|" 13613"|"ANNUAL"|"01/01/2011"|"1955"|"13370"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Transportation Facility/Vehicle Maintenance"|"0"|"OTHER"|"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"16000"|"0"|"0"|"S"|"1998"|"15"|"0"|"Unable to determine years of last major reconstruct/Replace"|"1"|"WELL"|"S"|"1998"|"25"|"0"|"Unable to determine years of last major reconstruct/Replace"|"1"|"MUN_UTILIT"|"S"|"1998"|"25"|"0"|"Unable to determine years of last major reconstruct/Replace"|"1"|"S"|"1967"|"15"|"0"|"Unable to determine years of last major reconstruct/Replace"|"1"|"UTIL,SELF"|"BELOW"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2006"|"10"|"0"|"Need to continuously clean basin covers and sumps"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"183075"|"0"|"Replace sections of asphalt and base wehere severely cracked, provide new sealant on remaining portions of drive/parking"|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"35"|"0"||"1"|"S"|"1998"|"4"|"6500"|"Masonry rehab required on interior wall of the last bay"|"1"|"S"|"1998"|"25"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"|"Unable to determine years of last major reconstruct/Replace"|"1"|"U"|"U"|"1998"|"1"|"12000"|"Replace doors from maint bays to offices with fire rated doors and frames, replace all know style door hardware with lever style"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"5"|"10000"|"Replace all fixtures with T8 ballasts"|"1"|"1"|"E"|"2008"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"3"|"2220"|"Replace carpet in offices with indoor/outdoor carpet"|"1"|"INSTRUCT,COMMON"|"S"|"1998"|"5"|"3500"|"There appears to be VAT in driver's offic and should be removed and replaced with VCT"|"1"|"COMMON"|"S"|"2006"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2006"|"35"|"0"||"MASONRY,STEEL"|"0"|"1"||"1"|"0"|"0"|"1"|"1"||"S"|"1998"|"4"|"11375"|"The farthest bay from the office area is showing signs of deterioration in the CMU's"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"2"|"14000"|"Replace select hollow metal doors in the original section that have deteriorated"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"16"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1964"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1964"|"10"|"0"||"0"|||||"0"|"Domestic hot water is provided from the high school"|"1"|"S"|"1964"|"10"|"0"||"0"||"0"|"BOILERWATE"||"S"|"2009"|"30"|"0"||"1"|"S"|"1998"|"20"|"0"|"Diesel fuel piping system serving co-generation plant for production of electricity"|"1"|"S"|"1998"|"6"|"0"|"Building has limited A/C through the use of thru-wall terminals"|"0"||||"0"||"1"|"S"|"1967"|"10"|"0"||"0"||||"0"||"1"|"S"|"1967"|"6"|"0"||"1"|"S"|"1998"|"6"|"0"||"1"|"S"|"1998"|"6"|"0"||"0"||||"0"||"1"|"U"|"1998"|"1"|"5000"|"Additional emergency lighting is required"|"1"|"S"|"1998"|"10"|"0"|"Co-gen system at this facility"|"1"|"1"|"35000"|"Required to have a unisex handicap accessible bathroom facility"|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Maint bays"|"0"|||"1"|"1"||"Cost proivded in other sections of this report"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"|"No mechanical ventilation for this building"|"0"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"|||"1"|"1"||"GOOD"||"272670"|"U"|"0"|"Bernier, Carr and Associates, PC"|"327 Mullin Street, Watertown, NY 13601"|"315-782-8130"|"jjantzi@thebcgroup.com"|"Jason S. Jantzi, AIA"|"029165"|"I ACCEPT"|11/19/2010 3:03:11 PM| 49|"Island Trees UFSD"|"28022603"|"Michael F. Stokes Elementary School"|"0001"|"09/01/2010"|"100 OWL PLACE"|"LEVITTOWN "|" 11756"|"ANNUAL"|"04/01/2011"|"1953"|"84,200"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"558"|"K,1,2,3,4"|"0"|"0"|"0"|"558"|"0"|"0"|||"37"|"29,600"|"ART,GYM,HLTHSUITE,LIBBRARY,MULTIPURPO,MUSIC,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1953"|"30"|"0"|"Newer double walled fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1980"|"18"|"0"|"Have RPZ devices"|"1"|"MUN_UTILIT"|"S"|"1975"|"35"|"0"||"1"|"S"|"1953"|"20"|"50,000"|"Provide upgraded gas service for main boiler fuel."|"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"1"|"S"|"1953"|"10"|"0"||"0"||||"0"||"1"|"S"|"1953"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1953"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1953"|"5"|"70,000"|"Minor repair, cracfill and seal bus loop."|"1"|"CONCRETE"|"S"|"2010"|"5"|"15,500"|"Replace concrete at main entry plus an additional 10 flags."|"1"|"S"|"1953"|"5"|"15,000"|"Repair and overlay south asphalt play areas."|"1"|"S"|"1953"|"10"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1953"|"15"|"0"||"1"|"S"|"2001"|"10"|"245,000"|"Replace roofing at lower west wing-appears to be water trapped between roofing layers."|"1"|"S"|"1953"|"15"|"45,000"|"Rpr masonry/plaster crack in cafe,remove wood frame walls at basement key shop&rm 219A,build wall to enclose sw.gear in basement.Repl. art rooms base cabinets and counter(100&101)Reglaze sliding windows in 219B&OT/PT for code compliance."|"1"|"S"|"1953"|"10"|"18,000"|"Replace asbestos ceilings in rooms 219A, 219B & server room. Replace main office ceiling and lighting."|"1"|"S"|"1953"|"10"|"0"||"1"|"S"|"S"|"1953"|"10"|"26,500"|"Replace (4) pair gym doors, remove & replace deadlock hardware, add closers to serving line doors, add exit devices to smoke doors by gym & install ADA hardware at required locations."|"1"|"S"|"1953"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"10"|"100,000"|"Replace existing panel interiors/breakers (for old branch panels). Electrical service and switchgear are new."|"1"|"S"|"1953"|"10"|"100,000"|"Replace old T-8 modified egg crate style fixtures."|"1"|"1"|"S"|"1953"|"0"|"160,000"|"System in working order, but should be replaced due to age and parts unavailability."|"1"|"S"|"1953"|"18"|"0"|"Continue to monitor and maintain"|"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1953"|"10"|"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"SLABGRADE,OTHER"|"One way reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1953"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"0"|"0"|"1"||"S"|"1953"|"10"|"163,500"|"Repl lntls at 1st fl.Eside,W.gym lintel, portion ofN.gym and cafelntls&repair mason lntls aroundN&Ekitchwalls.Rpr masonryoutside room 110,brick in N/W gym corner,N/E cafeteria corner,cut in several CJs around bldg.paint all lntls."|"1"|"MASONRY"|"S"|"1953"|"10"|"9,500"|"Repoint upper 8 ft. of chimney and reinstall upper corner cap block."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"||"1"|"S"|"1953"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"15"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"1"||"S"|"2001"|"10"|"245,000"|"Replace roofing at lower west wing-appears to be water trapped between roofing layers."|"0"|||||"0"||"1"|"COPPER"|"S"|"1953"|"18"|"0"|"Continue to monitor and maintain"|"1"|"IRON"|"S"|"1953"|"18"|"0"|"Repair leaks from toilet room above room 122. Continue to monitor and maintain."|"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"Units in good working order."|"1"|"S"|"1953"|"0"|"40,000"|"Fixtures old, but in good condition. Some have been replaced. Continue to monitor and maintain. Cost shown is for replacement of hose bibs and drinking fountains."|"0"||"1"|"BOILERSTEA"||"E"|"2005"|"30"|"40,000"|"Replace old vacuum/condensate unit. Replace single swing barometric damper with double swing type, including spill switches."|"1"|"S"|"1953"|"30"|"0"|"Have double walled underground FOST, relatively new."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"1953"|"18"|"0"|"Continue to monitor and maintain."|"1"|"S"|"1953"|"0"|"0"|"Continue to monitor and maintain"|"1"|"S"|"2005"|"25"|"30,000"|"Expand basic DDC control systemt o control all existing roof fans."|"1"|"E"|"2009"|"29"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"S"|"1953"|"1953"|"0"|"Kitchen hood fire suppression system-inspected annually. Good working order."|"1"|"S"|"1953"|"10"|"20,000"|"Replace various exit signs with LED type with battery backup. Add emergency lighting where applicable."|"0"||||"0"||"1"|"0"|"120,000"|"Reconstruct boys and girls toilet rooms for HCA"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"|"Lighting systems in good condition. Replace bym lights for better efficiency."|"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"1"|||"0"|"1"|"1"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Unit ventilators/controls have been replaced."|"1"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"1"|"1"|"0"|"GOOD"||"1,268,000"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 East Main Street"|"631-475-0349"|"rettig@bbsarch.com"|"Joseph B. Rettig, AIA"|"032280"|"I ACCEPT"|11/19/2010 3:56:37 PM| 50|"Island Trees UFSD"|"28022603"|"Stephen E. Karopczyc School"|"0008"|"08/31/2010"|"38 FARMEDGE ROAD "|"LEVITTOWN "|" 11756"|"ANNUAL"|"04/01/2011"|"1949"|"43,400"|"1"|"0"|"2"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Scope (District-Wide Pre-K)"|"150"|"Pre-K,K"|"0"|"0"|"1"|"150"|"0"|"0"|||"20"|"16,800"|"ADMIN,AUDITORIUM,GYM,PREK"||"1"|"0"|"0"|"1"|"6,000"|"S"|"1949"|"30"|"0"|"Newer double walled fiberglass tank"|"1"|"MUN_UTILIT"|"S"|"1980"|"14"|"0"|"Has RPZ devices"|"0"|"MUN_UTILIT"|"S"|"1975"|"25"|"0"||"1"|"S"|"1949"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"1"|"S"|"1949"|"14"|"0"||"1"|"S"|"1949"|"15"|"90,000"|"Provide leaching pools and connect downspouts"|"1"|"S"|"1949"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1949"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1989"|"5"|"105,500"|"Minor repair, crackfill and seal parking lot"|"1"|"CONCRETE"|"S"|"2010"|"10"|"0"||"0"|"S"|"1987"|"5"|"0"||"1"|"S"|"1949"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1949"|"15"|"0"||"0"|"S"|"1949"|"15"|"0"||"1"|"S"|"1949"|"15"|"3,500"|"Remove water damaged gypsum board and furring in basement"|"1"|"S"|"2010"|"10"|"14,500"|"Replace ceiling and lighting in room 101"|"0"||||"0"||"1"|"S"|"S"|"1949"|"10"|"10,000"|"Allowance for ADA hardware where necessary."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"10"|"60,000"|"Replace older existing panel interiors/breakers."|"1"|"S"|"1949"|"20"|"75,000"|"Replace incandescent lighting in gym."|"1"|"1"|"S"|"1949"|"20"|"0"|"System relatively new and in good working order"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"1949"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1949"|"10"|"0"|"Asbestos tile present throughout facility and beneath carpte and VCT"|"1"|"COMMON"|"S"|"1949"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"SLABGRADE,OTHER"|"Reinforced one-way concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1949"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1949"|"15"|"25,000"|"Repair masonry at gym window lintel, areas of removed trees and other minor masonry repair."|"1"|"MASONRY"|"S"|"1949"|"5"|"48,000"|"Remove and rebuild brick veneer, add S/S cap."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"||"1"|"S"|"1949"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"15"|"25,000"|"Replace boiler room glass block with aluminum windows. Repair defective gym window operators."|"WOODONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"1,500"|"Repair section of gutter over library entrance."|"0"|||||"0"||"1"|"COPPER"|"S"|"1949"|"14"|"0"|"Continue to monitor and maintain"|"1"|"IRON"|"S"|"1949"|"14"|"0"|"Restore function of basement and areaway floor drains. Continue to monitor and maintain."|"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"Unit in good working order"|"1"|"S"|"1949"|"0"|"125,000"|"Fixtures old, but in good condition. Some have been replaced. Continue to monitor & maintain. Cost shown if bathrooms are to be renovated."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2005"|"25"|"250,000"|"Only 1 boiler was replaced in 2005. Replace 2nd boiler and related equipment."|"1"|"E"|"1949"|"20"|"50,000"|"Have double walled underground FOST, relatively new. Provide new natural gas service for main boiler fuel."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1949"|"0"|"800,000"|"Convert bldg. to unit ventilator or similar terminal units (instead of central AHU), or install new dedicated o.a. system w/ heat recovery."|"1"|"S"|"1949"|"14"|"0"|"Continue to monitor and maintain."|"0"|"NF"|"1949"|"0"|"100,000"|"Replace non-functional gym AHU's"|"1"|"S"|"1949"|"0"|"175,000"|"Replace pneumatic control system with DDC controls."|"1"|"E"|"2008"|"28"|"0"||"1"|"S"|"2008"|"28"|"0"||"0"||||"0"||"0"|"S"|"1949"|"10"|"15,000"|"Replace using LED type with battery backup. (Some currently being done)."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE,OTHER"|"GOOD"|"Lighting old and inefficient. Recommend full replacement."|"1"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"1"||"See items 46 and 47"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"|"Recommend updating temperature control system."|"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"WARMING"|"1"|"1"|"0"|"GOOD"||"1,973,000"|"U"|"0"|"BBS Architects and Engineer, P.C."|"244 East Main Street"|"631-475-0349"|"rettig@bbsarch.com"|"Joseph B. Rettig, AIA"|"032280"|"I ACCEPT"|11/19/2010 4:37:51 PM| 53|"Fishers Island UFSD"|"58100402"|"Fishers Island School"|"0001"|"11/10/2010"|"PO DRAWER A GREENWOOD RD"|"FISHERS ISLAND "|" 06390"|"ANNUAL"|"05/01/2011"|"1972"|"27520"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"75"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"0"|"0"|"75"|"0"|"0"|||"15"|"9560"|"ADMIN,ART,AV,COMPROOM,GYM,HLTHSUITE,HOMECAREER,LIBBRARY,MUSIC,PREK,SCIENCELAB,SPECED,TECHSHOP,OTHER"|"Darkroom"|"1"|"0"|"0"|"1"|"8000"|"E"|"2004"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"10"|"0"||"1"|"SITESEPT"|"S"|"1972"|"5"|"0"||"1"|"S"|"1985"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"20"|"0"||"0"||||"0"||"1"|"S"|"1972"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1972"|"5"|"0"||"1"|"CONCRETE"|"S"|"2009"|"5"|"30000"|"30 concrete flags to be replaced"|"1"|"S"|"2000"|"5"|"10000"|"replace perimeter RR ties around playground & remulch"|"1"|"S"|"1985"|"5"|"0"|"N"||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"|"caulk & seal in library & at exit in stage area"|"1"|"S"|"2004"|"15"|"2000"|"install tight smoke seal between interior corridor walls & metal deck"|"1"|"S"|"1985"|"5"|"1000"|"replace damaged tile in corridor near gym"|"1"|"S"|"2005"|"5"|"0"||"1"|"S"|"U"|"2007"|"7"|"10000"|"install magnetic hold open devices tied to fire alarm system"|"1"|"S"|"1972"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"5"|"0"||"1"|"S"|"2006"|"5"|"0"||"1"|"1"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"5"|"12000"|"replace as needed"|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"5"|"12000"|"replace as needed"|"1"|"COMMON"|"S"|"1972"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"repoint and replace cracked masonry at souteast entry area"|"S"|"2004"|"3000"|"0"|"monitor or repair minor cracks"|"1"|"METAL"|"S"|"1990"|"5"|"0"|"rusted boiler flue checked by heating contractor- OK 2006"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"2"|"15000"|"replace 6 exterior & 2 courtyard doors"|"1"|"S"|"2005"|"10"|"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"Y"|"2006"|"10"|"0"|"some rescue windows are 21" in width"|"METONMET,WOODONWOOD"|"SINGLEPLY,ASPHALT,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"10"|"0"|"remove abandoned satellite dishes & solar panels from roof (some supports severely rusted)"|"0"|||||"0"||"1"|"COPPER"|"S"|"1972"|"10"|"0"||"1"|"IRON"|"S"|"1972"|"10"|"0"||"1"|"OIL"|"E"|"2009"|"14"|"0"|"no longer supplemented by solar panels"|"1"|"S"|"1972"|"5"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"2005"|"11"|"0"||"1"|"S"|"2004"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"2005"|"5"|"0"||"1"|"S"|"2004"|"5"|"55000"|"upgrade to meet ADA requirements "|"1"|"S"|"2004"|"5"|"0"|"install additional smoke detection (see fire alarm system)"|"0"||||"0"||"0"|"S"|"2009"|"5"|"10000"|"update & add emergency and exit lighting as needed throughout"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"0"||"FULL"||"1"||"FAIR"||"231000"|"S"|"0"|"ECG Engineering, LLC"|"22 Lawrence Ave, Suite 300, Smithtown"|"631-360-0006"|"info@ecgengineers.com"|"Lloyd Howell, PE "|"1652949"|"i accept"|11/21/2010 4:25:58 PM| 54|"BOCES Wayne-Finger Lakes"|"43900000"|"Auto Shop ST-TEP"|"0005"|"09/23/2010"|"3501 County Road 20"|"Stanley"|" 14561"|"ANNUAL"|"08/01/2011"|"1973"|"2500"|"1"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"44"|"9,10,11,12"|"0"|"1"|"0"|"44"|"0"|"0"|||"1"|"2200"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"30"|"0"||"1"|"SITESEPT"|"S"|"1993"|"40"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"35"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2005"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"50"|"0"||"1"|"S"|"2001"|"50"|"0"||"1"|"S"|"1973"|"30"|"0"||"1"|"E"|"2001"|"30"|"0"||"0"||||"0"||"1"|"S"|"S"|"2001"|"30"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"35"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"1"|"S"|"2001"|"8"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1973"|"20"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"40"|"0"||"STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"35"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"30"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"Y"|"2001"|"20"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2000"|"30"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2000"|"30"|"0"||"1"|"PVC"|"S"|"2000"|"30"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"2"|"3500"|"Not ASME, provide propane instant water heaters."|"1"|"S"|"2000"|"25"|"4,500/12,800"|"Replace emergency eyewash/replace fixture trim with flush valves and faucets with sensor type."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2001"|"21"|"0"||"1"|"S"|"2001"|"26"|"0"||"0"||||"0"||"0"||||"88000"|"Provide ventilation, vehicle exhaust drops, heat and building controls. Ventilation is not per code."|"1"|"S"|"2001"|"36"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"1"|"1"|"1"|"0"|"1"|"0"|"0"|||"0"|"1"||"FAIR"||"0"|"S"|"0"|"Beardsley Design Associates"|"64 South Street"|"315-253-7301"|"bda@beardsley.com"|"Steven F. Moolin, R.A."|"021568"|"I ACCEPT"|11/22/2010 2:45:14 PM| 55|"Canajoharie CSD"|"27030104"|"East Hill School"|"0002"|"06/01/2010"|"25 School District Rd."|"Canajoharie"|" 13317"|"ANNUAL"|"1/11/11"|"1951"|"158427"|"2"|"7"|"2"|"DISTRICT"|"INSTRUCT"||"244"|"Pre-K,K,1,2,3,4,5,6,7,8"|"0"|"1"|"1"|"244"|"0"|"0"|||"55"|"42851"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"50"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"||"1"|"E"|"2003"|"30"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2003"|"30"|"0"|"New electrical service 2003, panel replacement 2009"|"1"|"S"|"2009"|"25"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"1"|"E"|"2003"|"30"|"0"|"Drywell retention provided at 2003 elementary building storm drain with outlet to municipal storm system."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"CONCRETE"|"S"|"2009"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"|"Playground surface material to be replaced"|"1"|"S"|"1975"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"50"|"0"||"1"|"S"|"1966"|"50"|"0"|"Interior Corridor bearing walls in 1952, 1966 wings"|"1"|"S"|"2003"|"30"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"|"Original lockers remain in 1951 2 story building corridor. All other corridor lockers replaced 2009. "|"1"|"S"|"E"|"2009"|"20"|"0"|"Majority of interior doors and hardware replaced in 1951 and 1966 wings"|"1"|"S"|"2003"|"50"|"0"|"New addition stairs in 2003. 1966 building stairs provided with smoke doors in 2009."|"1"|"E"|"2009"|"25"|"0"|"new elevator in 2003 addition, stair lifts provided for Nellis pool building 2006."|"1"|"1"|"E"|"2009"|"30"|"0"||"1"|"E"|"2009"|"15"|"0"||"0"|"1"|"S"|"2001"|"15"|"0"||"1"|"E"|"2009"|"50"|"0"|"Structural repairs, new hvac systems misc. repairs in 2009."|"1"|"COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"15"|"0"||"1"|"COMMON"|"E"|"2009"|"15"|"0"||"1"|"COMMON"|"S"|"1961"|"15"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"reinforced conc. clay tile composite 1952 bldg"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"50"|"0"|"Brick repointing/repairs done at misc. locations 2009"|"1"|"MASONRY"|"S"|"2009"|"25"|"0"|"Partial repointing 2009"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"E"|"Y"|"2003"|"25"|"0"||"METONMET,OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"1"|"PLASTIC"|"E"|"2009"|"15"|"0"||"1"|"COPPER"|"E"|"1998"|"30"|"0"||"1"|"IRON"|"S"|"2009"|"20"|"0"|"some drainage repair work anticipated at ES locker rooms and nearby"|"1"|"NAT_GAS"|"E"|"2001"|"15"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"E"|"2003"|"20"|"0"|"Boiler tubes replaced in 2007"|"1"|"E"|"2003"|"25"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"2009"|"30"|"0"|"EMS head end at HS should be upgraded"|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"E"|"2007"|"2007"|"0"|"Provided new ansul system at kitchen hood"|"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"1"|"FAIR"|"Classroom UV upgraded to meet current ventilation requirements 2009"|"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"75000"|"S"|"0"|"Glynn Spillane Griffing Architects pc"|"187 Wolf Road, Albany N.Y."|"518 463 1114"|"rmichel@gsgarchitects.com"|"Richard Michel"|"022253"|"i accept"|11/22/2010 2:49:07 PM| 57|"Bethpage UFSD"|"28052103"|"CHARLES CAMPAGNE ELEMENTARY"|"0007"|"07/12/2010"|"601 PLAINVIEW ROAD"|"BETHPAGE"|" 11714"|"ANNUAL"|"04/01/2011"|"1961"|"60,674"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"438"|"K,1,2,3,4,5"|"0"|"0"|"1"|"438"|"0"|"0"|||"23"|"20,700"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1961"|"5"|"0"|"Below grade transformer"|"0"|"MUN_UTILIT"|"S"|"1987"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1961"|"10"|"0"||"1"|"S"|"1995"|"12"|"0"|"Gas feeds Kitchen, hot water heater & burner pilots."|"1"|"UTIL"|"BELOW"|"S"|"1961"|"5"|"0"||"1"|"E"|"2008"|"15"|"0"||"0"||||"0"||"1"|"E"|"2008"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"10"|"20,000"|"Several pavement areas in need of replacement & Bus loop asphalt needs reconstruction."|"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"10"|"0"|"Several concrete & asphalt areas around building need replacement."|"1"|"E"|"2007"|"15"|"0"||"1"|"S"|"2006"|"10"|"0"|"N"|"Routine maintenance performed by District."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1961"|"20"|"0"||"1"|"S"|"1961"|"20"|"56,000"|"Extensive masonry cracks at Stage. Repair cracks in Gym."|"1"|"S"|"1961"|"20"|"8,000"|"Mortar cracks in K-A, Kitchen & Room 206 at window wall."|"1"|"S"|"2008"|"15"|"53,000"|"Replace perforated metal pan ceiling in Kitchen & plaster ceiling in converted Locker Room."|"0"||||"0"||"1"|"S"|"S"|"2010"|"8"|"26,500"|"Recommend starting program to replace interior doors & hardware per ADA requirements."|"1"|"S"|"1961"|"12"|"0"|"Recommend replacing railing for all stairs within the building to 4" diameter sphere."|"1"|"E"|"2003"|"20"|"0"||"1"|"1"|"S"|"2002"|"10"|"55,000"|"Expand interior distribution to accommodate computer needs."|"1"|"S"|"2008"|"15"|"0"|"Lighting & lighting controls replaced as part of ESCO."|"1"|"1"|"S"|"2002"|"15"|"28,000"|"Simplex 5120 communication system. Request separate P/A system in Cafeteria."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2005"|"10"|"223,750"|"Recommend replacement of remaining VAT flooring."|"1"|"COMMON"|"E"|"1961"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2007"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1961"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"1"|"1"|"0"|"0"||"S"|"2004"|"15"|"13,200"|"Minor brick repair required."|"1"|"MASONRY"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2005"|"20"|"0"||"1"|"S"|"1961"|"15"|"12,000"|"Replace railing @ north end of site."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"20"|"0"||"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2003"|"12"|"4,000"|"Raise (2) central exhaust fans on upper roof over corridor."|"1"|"PLASTIC"|"S"|"2003"|"12"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2010"|"15"|"8,000"|"Main shut-off inside building does not work. Partial replacement of piping as part of toilet reconstruction work."|"1"|"IRON"|"S"|"2010"|"20"|"0"|"Partial replacement as part of multi-stall toilet reconstruction."|"1"|"NAT_GAS"|"E"|"2010"|"20"|"0"|"Replaced as part of 2010 ESCO"|"1"|"E"|"2010"|"20"|"0"|"Continuation of multi-stall bathroom Reconstruction"|"0"||"1"|"BOILERWATE"||"E"|"2010"|"30"|"0"|"All upgraded as part of 2010 ESCO project"|"0"|"E"|"2010"|"30"|"0"||"1"|"S"|"2007"|"10"|"0"|"A/C window units"|"1"|"S"|"2010"|"15"|"15,000"|"Music Office requires fresh air ventilation. UV's well maintained."|"1"|"S"|"1961"|"5"|"0"||"1"|"S"|"1961"|"5"|"0"||"1"|"S"|"2003"|"5"|"35,000"|"Pneumatic refurbishing recommended - new DDC front-end"|"1"|"S"|"2002"|"15"|"0"|"Smplex 4010 FA System"|"1"|"S"|"2002"|"15"|"0"|"Simplex 4010 FA System"|"1"|"S"|"2009"|"2009"|"0"|"Annual inspections of existing system"|"1"|"E"|"2002"|"10"|"0"|"Emergency & exit lights replaced in 2002"|"1"|"NF"|"1961"|"0"|"100,000"|"Battery panels in exit & emergency lighting"|"1"|"1"|"61,500"|"Provide sink/bubbler; provide 1 ADA sink/bubbler; provide drinking fountain-2nd floor."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"|"Lighting & lighting controls upgraded in 2008 & 2010."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"869,450.00"|"U"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|11/22/2010 3:50:14 PM| 58|"Spencerport CSD"|"26100106"|"Wm.C. Munn Elementary "|"0015"|"04/19/2010"|"1 RANGER ROAD "|"SPENCERPORT "|" 14559"|"ANNUAL"|"09/01/11"|"2003"|"86,432"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"475"|"K,1,2,3,4,5"|"0"|"1"|"1"|"475"|"0"|"0"|||"32"|"38,260"|"ADMIN,ART,AUDITORIUM,GYM,KITCHEN,LIBBRARY,MUSIC"||"1"|"0"|"0"|"1"|"10,000"|"E"|"2003"|"25"|"0"|"Three (3) GPM duplex Simplex #SKS-30 transfer pumps."|"1"|"MUN_UTILIT"|"E"|"2003"|"25"|"0"|"3" service to boiler room. 3" meter without backflow preventer. Recommend adding back-flow preventer."|"1"|"MUN_UTILIT"|"E"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"|"4" service, RG&E # 629646."|"1"|"UTIL"|"BELOW"|"E"|"2003"|"32"|"0"|"Exterior pad-mounted transformer with underground primary."|"1"|"S"|"2003"|"25"|"0"||"0"||||"0"||"1"|"S"|"2003"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"30"|"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"0"|"Mill and resurface access road in front of school. Seal other pavements."|"1"|"ASPHALT"|"S"|"2003"|"10"|"0"|"Spot repairs and sealing of asphalt walks required. "|"1"|"S"|"2003"|"10"|"0"|"Miscellaneous repairs to basketball courts and playground mulching needed. "|"1"|"S"|"2003"|"35"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2003"|"40"|"0"||"1"|"S"|"2003"|"50"|"0"||"1"|"S"|"2003"|"50"|"0"||"1"|"S"|"2003"|"12"|"0"|"Some evidence of stains on ceilings. "|"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"S"|"2003"|"20"|"0"||"1"|"E"|"2003"|"40"|"0"||"0"||||"0"||"1"|"1"|"E"|"2002"|"32"|"0"||"1"|"S"|"2003"|"13"|"0"||"1"|"1"|"E"|"2003"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"COMMON"|"S"|"2003"|"30"|"0"|"Areas of cracked tile and grout exist. "|"1"|"INSTRUCT"|"S"|"2003"|"30"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2003"|"40"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2003"|"40"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2003"|"20"|"0"||"1"|"S"|"2003"|"5"|"2,970.00"|"Handrail needs repair at Loading Dock. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"1"|"0"|"1"||"S"|"2003"|"5"|"352,413.00"|"Roof overall is satisfactory. There are locations that need attention. Roof is not adequately sloped to drains. "|"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"20"|"0"|"Aerco KC1000 heater, no storage. Heater set at 140 degrees. 110 degrees loop to lavatories. 140 degrees loop to Kitchen. "|"1"|"E"|"2003"|"30"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2003"|"20"|"0"|"Three Aerco Benchmark 2.0 (20,000 mbh each) natural gas boilers. One Dedietrich firetube (4,100 mbh) dual fuel(nat. gas/fuel oil)boiler. Boilers provide hot water to unit ventilators, air handling units, perimeter radiation,cabinet heaters. "|"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Suction line on EMI units should be insulated. Trane condensing units provide cooling to four air handlers serving admin office, Library, Cafeteria and Computer Lab. EMI split systems provide cooling to Server rooms in each wing."|"1"|"S"|"2003"|"20"|"0"|"Equipment consists of unit ventilators, 6 Trane air handlers, roof-mounted exhaust fans, make-up air unit to kitchen hood.All equipment in good condition."|"1"|"S"|"2003"|"20"|"0"|"2 10-HP Taco pumps circulate hot water. Several in-line Taco pumps serve parallel loops off main system. All observed piping is insulated. Pumps, wall radiation, insulation appear in good condition."|"1"|"S"|"2003"|"20"|"0"|"All observed ductwork for air handlers is insulated and in good condition."|"1"|"S"|"2003"|"10"|"0"|"Invensys control system installed with District-wide control system in 2003. Service provided by outside company. Observed equipment in good condition."|"1"|"E"|"2003"|"20"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"2003"|"2003"|"0"|"Building is not sprinklered. Ansul system at Kitchen hood. "|"1"|"E"|"2003"|"22"|"0"||"1"|"E"|"2003"|"17"|"0"|"Generator supports exit signs, emergency lighting ans fire alarm system."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,OTHER"|"Library"|"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Filters observed to be clean. Ventilation confirmed to each space."|"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"1"|"FIREALARM,LIGHTING"|"FULL"||"1"||"GOOD"||"$2,365,449.00"|"S"|"1"|"LaBella Associates, P.C."|"300 State St., Suite 201, Rochester,N.Y. 145614"|"585-454-6110"|"mshort@labellapc.com"|"Michael E. Short"|"032717"|"I ACCEPT"|11/22/2010 3:57:56 PM| 59|"Medina CSD"|"45080106"|"Oak Orchard Elementary School"|"0002"|"11/4/09"|"335 West Oak Orchard Street"|"Medina"|" 14103"|"ANNUAL"|"7/1/11"|"1952"|"94150"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"422"|"3,4,5"|"0"|"1"|"1"|"422"|"0"|"0"|||"38"|"30500"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"1"|"500"|"0"|"0"|"E"|"2003"|"18"|"0"|"Above ground fuel tank with fence and containment installed in 2003."|"1"|"MUN_UTILIT"|"E"|"2009"|"35"|"0"|"New water service piping to building installed in 2009."|"1"|"MUN_UTILIT"|"S"|"1952"|"20"|"0"|"Hydro flushing sewer cleaning in 2009. No reported issues."|"1"|"E"|"2009"|"30"|"0"|"Replaced gas service main in 2009."|"1"|"UTIL"|"BELOW"|"E"|"2009"|"30"|"0"|"New underground primary cables installed in 2009."|"1"|"E"|"2009"|"35"|"0"|"Stormwater drainage system added at Bus Loop in 2009."|"0"||||"0"||"1"|"E"|"2009"|"35"|"0"|"Catch basins added at Bus Loop in 2009."|"0"||||"0"||"0"|"MUNI"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2008"|"20"|"342443"|"Bus Loop repaved in 2008. New student drop off loop should be considered in the future."|"1"|"CONCRETE"|"S"|"2008"|"20"|"30996"|"Replace concrete and asphalt pads at the end of the 3rd and 5th grade classrooom wings."|"1"|"S"|"2006"|"20"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1954"|"20"|"0"||"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"30"|"50896"|"Add new wall padding in the Gym and Play Room."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"S"|"2009"|"15"|"86046"|"Added new lever sets at corridor doors in 2009. Additional hardware upgrades required."|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"1"|"S"|"2009"|"20"|"0"|"Main Service entrance equipment replace in 2009."|"1"|"S"|"2003"|"20"|"0"||"1"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"20"|"0"|"Carpet installed in Main Office and Auditorium as part of the last project."|"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"COMMON"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1952"|"10"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Structural Concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1954"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1954"|"20"|"26191"|"Repair cracks in the front walls of the school near the auditorium. New thru wall flashing installed at upper walls and roof in 2008."|"1"|"MASONRY"|"S"|"2008"|"15"|"0"|"Portions of the chimney were repointed in 2008."|"0"|||||"0"||"S"|"S"|"1"|"1"|"2009"|"20"|"0"|"New security system installed in 2009. Main entrance doors replaced in 2009."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"6"|"46820"|"Replace glazing that has lost its seal. Some of the worst windows were replaced in 2008."|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"25"|"0"|"Entire roof replaced in 2008."|"1"|"PLASTIC"|"E"|"2008"|"20"|"0"||"1"|"COPPER"|"E"|"2009"|"35"|"0"|"Domestic Water piping in crawl space replaced with copper in 2009."|"1"|"IRON,COPPER"|"S"|"2003"|"20"|"8250"|"Install grease interceptor on exisiting dishwasher waste at kitchen in next project."|"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"|"Water heaters and tanks installed in 2003. Abandoned storage tank removed in 2009."|"1"|"S"|"2003"|"15"|"0"|"Mix of 1952 and newer fixtures, no reported issues."|"0"||"1"|"BOILERWATE"||"S"|"2003"|"20"|"0"|"No reported issues."|"1"|"S"|"2003"|"20"|"0"|"No reported issues."|"1"|"S"|"2009"|"15"|"0"|"New auditorium rooftop AHU's and Main Office PTAC units."|"1"|"S"|"2003"|"15"|"381000"|"Update relief and ventilation at classrooms, gym & crawlspace."|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2009"|"20"|"0"|"No reported issues."|"1"|"S"|"2003"|"10"|"0"|"No reported issues."|"1"|"U"|"1985"|"5"|"118000"|"Replace system complete."|"1"|"U"|"1985"|"5"|"see item 93"|"Smoke detection coverage is minimal."|"1"|"S"|"1985"|"1985"|"0"|"District shall continue to have annual kitchen hool supression system inspection."|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"1989"|"10"|"0"|"No reported issues."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"|"Need to improve the acoustics in the Gym and Play Room."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"1399415"|"U"|"1"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/22/2010 4:05:39 PM| 60|"Medina CSD"|"45080106"|"Warren P. Towne Elementary School"|"0009"|"11/4/09"|"181 Bates Road"|"Medina"|" 14103"|"ANNUAL"|"7/1/11"|"1968"|"67715"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"463"|"Pre-K,K,1,2"|"0"|"1"|"1"|"463"|"0"|"0"|||"33"|"27855"|"ADMIN,ART,AV,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"|"No reported issues."|"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"|"No reported issues."|"1"|"S"|"1968"|"15"|"0"|"No reported issues."|"1"|"UTIL"|"BELOW"|"S"|"1968"|"10"|"0"||"1"|"E"|"2009"|"35"|"0"|"Storm water drainage system replaced at bus drop off loops in 2009."|"0"||||"0"||"1"|"E"|"2009"|"35"|"0"|"Catch basins replaced at bus drop off loops in 2009."|"1"|"S"|"1968"|"15"|"0"|"No reported issues."|"1"|"MUNI"||"0"|"S"|"2009"|"35"|"0"|"Discharge is through municipal system."|"0"||||"0"||"1"|"E"|"2009"|"35"|"0"|"Underground 24" retention pipes installed on west side of Bates Road in 2009."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"|"Bus loop in front of school, and drop off loop in back of school repaved in 2009. "|"1"|"CONCRETE"|"E"|"2009"|"20"|"0"|"A majority of the sidewalks around the building were replaced in 2009."|"1"|"S"|"2003"|"10"|"0"|"Provide new fencing around the playground. See item #55."|"1"|"S"|"1968"|"3"|"57351"|"N"|"Repave existing basketball courts and provide new fencing around the perimeter of the playground."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"30"|"1760"|"Minor repair near back loading dock required."|"1"|"S"|"2003"|"25"|"0"|"Existing corridor walls do not extend to the underside of the deck. PENC"|"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2009"|"3"|"122197"|"Install new 2'x2' acoustical ceiling tile in classrooms and Media Center."|"0"||||"0"||"1"|"S"|"S"|"2003"|"15"|"45980"|"Hardware upgrades required at interior doors."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"20"|"0"|"Main service entrance equipment and branch panels replaced in 2009."|"1"|"E"|"2003"|"15"|"0"||"1"|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"6"|"2314"|"Replace carpet in Storage Room B-139."|"1"|"COMMON"|"S"|"2003"|"15"|"0"||"1"|"COMMON"|"S"|"2003"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1968"|"15"|"0"|"Gym floor is original."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"25"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2003"|"15"|"0"|"New security system installed in 2009."|"1"|"S"|"2003"|"12100"|"0"|"Replace metal steps up to back loading dock with new concrete steps."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"15"|"0"|"All window glazing replaced in 2009 project."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"25"|"0"|"Entire roof replaced in 2009 except for addition that was installed in 2003."|"1"|"PLASTIC"|"E"|"2009"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"20"|"0"|"Water meter and main shut off valves replaced in 2009. No reported issues."|"1"|"IRON,COPPER"|"S"|"2009"|"25"|"8250"|"Install grease interceptor on existing dishwasher waste at kitchen in next project."|"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"|"New water heaters and storage tanks installed in 2009."|"1"|"S"|"2003"|"15"|"0"|"Mix of 1968 and newer fixtures. No reported issues."|"0"||"1"|"BOILERWATE"||"E"|"2009"|"25"|"0"|"New boilers installed in 2009."|"1"|"S"|"2009"|"20"|"0"|"No reported issues."|"1"|"S"|"2009"|"15"|"0"|"Added split air conditioning systems to misc. classrooms in 2009."|"1"|"S"|"2009"|"30"|"150000"|"Classroom unit ventilators replaced in 2009. Need to replace kitchen and gym AHU's."|"1"|"S"|"2009"|"20"|"0"|"Replaced hot water heating pumps in 2009."|"1"|"S"|"2009"|"20"|"0"|"No reported issues."|"1"|"E"|"2009"|"20"|"0"|"No reported issues."|"1"|"S"|"1999"|"5"|"93500"|"Replace system complete."|"1"|"S"|"2003"|"5"|"0"||"1"|"S"|"1999"|"1999"|"0"|"District shall continue to have annual kitchen hood supression system inspection."|"1"|"E"|"2003"|"20"|"0"||"1"|"S"|"1989"|"10"|"0"|"No reported issues."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"Add acoustic panels in Choral Room."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"0"|"1"||"GOOD"||"1266762"|"S"|"1"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/23/2010 10:20:40 AM| 61|"Canajoharie CSD"|"27030104"|"Bus Garage"|"4015"|"08/18/2010"|"76 carlisle road"|"Canajoharie "|"13317"|"ANNUAL"|"01/11/2011"|"2003"|"22125"|"1"|"7"|"2"|"DISTRICT"|"OTHER"|"Bus Maintenance and Storage"|"0"||"0"|"0"|"0"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2003"|"30"|"0"||"1"|"MUN_UTILIT"|"E"|"2003"|"30"|"0"||"1"|"E"|"2003"|"30"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2003"|"30"|"0"||"1"|"E"|"2003"|"30"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"E"|"2003"|"30"|"0"||"1"|"E"|"2003"|"30"|"0"||"1"|"ONSITE"||"1"|"E"|"2003"|"25"|"0"||"0"||||"0"||"1"|"E"|"2003"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2003"|"25"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2003"|"50"|"0"||"0"||||"0"||"1"|"E"|"2003"|"50"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"E"|"2003"|"15"|"0"||"1"|"S"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2003"|"30"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"1"|"E"|"2003"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2003"|"15"|"0"||"1"|"COMMON"|"E"|"2003"|"50"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2003"|"50"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2003"|"50"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2003"|"25"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2003"|"25"|"20000"|"Gutter maintenance and tie in to drains needed"|"0"|||||"0"||"1"|"COPPER"|"E"|"2003"|"30"|"0"||"1"|"IRON"|"E"|"2003"|"35"|"0"||"1"|"NAT_GAS"|"E"|"2003"|"15"|"0"||"1"|"E"|"2003"|"15"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2003"|"25"|"0"||"1"|"E"|"2003"|"25"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"E"|"2003"|"25"|"0"||"1"|"E"|"2003"|"25"|"25"||"1"|"E"|"2003"|"25"|"0"||"1"|"E"|"2003"|"30"|"0"|"ems head end located and HS, requires replacement"|"1"|"E"|"2003"|"15"|"0"||"1"|"E"|"2003"|"20"|"0"||"0"||||"0"||"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"20000"|"E"|"0"|"Glynn Spillane Griffing Architects PC"|"187 Wolf Road"|"518 463 1114"|"rmichel@gsgarchitects.com"|"Richard Michel"|"022253"|"I accept"|11/23/2010 10:44:56 AM| 62|"Medina CSD"|"45080106"|"Bus Garage"|"5005"|"11/4/09"|"1018 Gwinn Street"|"Medina"|" 14103"|"ANNUAL"|"7/1/11"|"1968"|"13320"|"1"|"1"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Grounds Storage, Bus Maintenance, Offices, District Storage"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"500"|"0"|"0"|"E"|"2003"|"15"|"0"|"Double wall with spill containment for diesel fuel."|"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"|"No reported issues."|"1"|"MUN_UTILIT"|"E"|"2003"|"30"|"0"|"New pump station, oil separator & sanitary mains from building in 2003."|"1"|"S"|"2003"|"15"|"0"|"Partial improvements made in 2003."|"1"|"UTIL"|"BELOW"|"S"|"2003"|"20"|"0"||"1"|"E"|"2003"|"30"|"0"|"No reported issues."|"0"||||"0"||"1"|"E"|"2003"|"30"|"0"|"No reported issues."|"1"|"S"|"1968"|"15"|"0"|"No reported issues."|"0"|||||||"0"||"0"||||"0"||"1"|"E"|"2003"|"15"|"0"|"No reported issues."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"13"|"0"||"1"|"CONCRETE"|"S"|"2009"|"20"|"0"|"Sidewalk at Transportation Office was installed in 2009."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2008"|"25"|"0"|"New office space constructed in 2008."|"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"20"|"1122"|"Install new closers and lever sets on doors."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"20"|"0"||"1"|"E"|"2003"|"20"|"0"||"1"|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"|"New carpet installed in Buildings & Grounds Office in 2008."|"1"|"COMMON"|"S"|"2008"|"20"|"0"||"1"|"COMMON"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2009"|"25"|"0"|"New security system installed in 2009."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"30"|"0"|"80% of distribution piping replaced in 2003."|"1"|"IRON,COPPER"|"S"|"2009"|"30"|"0"|"New piping installed in 2003. Mains cleaned to oil speerator, and pumps installed at lift trenches in 2009."|"1"|"NAT_GAS"|"S"|"2003"|"10"|"0"|"Water heater and distribution piping replaced in 2003."|"1"|"E"|"2003"|"25"|"0"|"All plumbing fixtures were replaced in 2003."|"0"||"1"|"FURNACE"||"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"25000"|"Need to add a tailpipe exhaust system for vehicle maintenance."|"0"||||"0"||"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"10"|"0"|"No reported issues."|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"26122"|"S"|"1"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/23/2010 11:16:17 AM| 67|"Medina CSD"|"45080106"|"Concession Stand"|"7013"|"11/4/09"|"335 West Oak Street"|"Medina"|"14103"|"ANNUAL"|"7/1/11"|"1976"|"1676"|"1"|"0"|"0"|"DISTRICT"|"OTHER,OTHER_ORG"|"Athletic Field Restrooms, Booster Club Concessions"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2003"|"35"|"0"|"New water service piping to building installed in 2003."|"1"|"MUN_UTILIT"|"E"|"2003"|"30"|"0"|"New sanitary from building and new football field drainage in 2003."|"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2003"|"20"|"0"||"1"|"E"|"2003"|"30"|"0"|"No reported issues."|"0"||||"0"||"1"|"E"|"2003"|"30"|"0"|"No reported issues."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"ASPHALT,OTHER"|"E"|"2009"|"15"|"0"|"New asphalt paving installed around building in 2009 project."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2003"|"30"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2009"|"25"|"0"|"New EIFS ceiling installed in last project."|"0"||||"0"||"1"|"S"|"S"|"2003"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2003"|"20"|"0"|"No reported issues."|"1"|"E"|"2009"|"20"|"0"|"Light fixtures replaced in food sales area."|"1"|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2003"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"OTHER"|"E"|"NA"|"2009"|"20"|"0"|"New stainless steel rolling shutters installed in 2009."|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2003"|"35"|"0"|"District shall continue to drain system in winter. New service in 2003."|"1"|"IRON,COPPER"|"E"|"2003"|"30"|"0"|"New piping in building below slab installed in 2003 addition."|"1"|"ELECTRIC"|"S"|"2003"|"10"|"0"|"District shall continue to drain down system in winter months."|"1"|"S"|"2009"|"20"|"0"|"Newer fixtures in 2003 addition. Service sink replaced with stainless steel hand washing sink in 2009."|"0"||"1"|"OTHER"|"unit ventilation"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"25"|"0"|"No reported issues."|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"|"No reported issues."|"0"||||"0"||"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"1"|"S"|"2003"|"15"|"0"|"No reported issues."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"41558"|"S"|"1"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/23/2010 2:18:24 PM| 72|"Mamaroneck UFSD"|"66070103"|"Transportation Office"|"5008"|"10/15/2010"|"119 Gertrude Avenue"|"Mamaroneck"|" 10543"|"ANNUAL"|"03/01/2011"|"1950"|"5400"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Storage and Maintenance"|"0"|||"0"|"0"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"15"|"0"||"1"|"S"|"1950"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1950"|"5"|"0"|"Water penetration at North wall"|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2001"|"15"|"0"|"Replaced hardware with ADA"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"1"|"E"|"2003"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"15"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"1"|"1"|"0"||"S"|"1950"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"15"|"0"|"Updated hardware for ADA"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL,VINYL"|"S"|"Y"|"2004"|"15"|"0"|"Replace exterior windows, Fire glazing @ interior windows."|"WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"1995"|"5"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2001"|"15"|"0"||"0"|"COPPER"|"S"|"2001"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2005"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||"1"|"FURNACE"||"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"0"|"30,000"|"No ADA Hardware or Lift"|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Storage Room"|"1"|"OTHER"|"Storage Room"|"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"|"Need exhaust fan in oil storage room."|"0"|"1"|"1"|"1"|"1"|"1"|"0"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"0"|"0"|"GOOD"||"100,000"|"S"|"0"|"LAN Associates, EPAS, LLP"|"252 Main Street, Goshen, NY 10924"|"845 615 0350"|"mjm@lan-nj.com"|"Michael J. McGovern"|"022257"|"I accept"|11/24/2010 12:27:59 PM| 73|"Laurens CSD"|"47080104"|"AMBROSE V. POWELL MEMORIAL LIBRARY"|"8008"|"08/24/2010"|"MAIN STREET"|"LAURENS"|" 13796"|"ANNUAL"|"12/01/2010"|"1967"|"1200"|"1"|"0"|"0"|"DISTRICT"|"OTHER_ORG"||"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"1"|"550"|"0"|"0"|"S"|"2002"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2007"|"18"|"0"||"1"|"SITESEPT"|"U"|"1967"|"5"|"66,000"|"Recommend replacing site sanitary system."|"0"||||"0"||"1"|"UTIL"|"ABOVE"|"U"|"1967"|"5"|"44,000"|"Recommend replacing/upgrading existing 100 amp, 1 ph, 3 wire, 240 v"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2008"|"15"|"0"||"1"|"CONCRETE"|"U"|"1967"|"5"|"5,000"|"Recommend ADA compliant sidewalk/entrance stair"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"15"|"3,000"|"Minor settlement cracks. Recommend parging in areas."|"1"|"S"|"1967"|"5"|"0"|"Recommend painting (cost included w/ Question #67)"|"1"|"U"|"1967"|"5"|"2,000"|"Recommend patching/painting."|"1"|"U"|"1967"|"5"|"12,000"|"Recommend replacing (gypsum drywall) ceiling & painting."|"0"||||"0"||"1"|"S"|"S"|"1967"|"5"|"8,000"|"Recommend replacing (2) 3'-0" doors w/ ADA hardware"|"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"1967"|"5"|"26,000"|"Recommend upgrading interior panel boards & branch circuitry."|"1"|"U"|"1967"|"5"|"35,000"|"Recommend replacing original T-12 lighting & add automatic controls."|"1"|"0"|"U"|"1967"|"0"|"35,000"|"Recommend expanding Main Bldg communications system to add Library phone/data - currently doesn't exist."|"0"||||"0"||"1"|"COMMON"|"U"|"1990"|"5"|"10,000"|"Recommend replacing carpet."|"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"20"|"0"||"MASONRY,WOOD,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"damaged vinyl siding"|"S"|"2002"|"15"|"0"|"Vinyl siding installed 2002 but has some damaged areas."|"1"|"MASONRY"|"S"|"1967"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1967"|"5"|"2,000"|"Recommend replacing (1) 3'-0" w/ new residential type door."|"1"|"U"|"1967"|"5"|"0"|"See question #53."|"0"|||||"0"||"1"|"VINYL"|"S"|"NA"|"2000"|"15"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Build-up of moss due to trees."|"U"|"1999"|"10"|"9,000"|"Replace roof system."|"0"|||||"0"||"1"|"COPPER"|"U"|"1967"|"5"|"4,000"|"Recommend replace & upgrade water distribution."|"1"|"IRON,COPPER"|"S"|"1967"|"10"|"0"||"1"|"ELECTRIC"|"U"|"1990"|"5"|"5,000"|"Recommend replacing water heater."|"1"|"U"|"1967"|"5"|"4,000"|"Recommend replacing w/ ADA compliant fixtures."|"1"|"CV"|"1"|"FURNACE"||"S"|"2010"|"15"|"0"|"Recommend clean ductwork (see question 80)."|"1"|"S"|"2010"|"15"|"0"||"0"|"U"|"1967"|"0"|"18,000"|"Recommend adding vent air & consider adding new central A/C to furnace - currently doesn't exist."|"1"|"U"|"1967"|"5"|"5,000"|"Provide toilet exhaust fans & controls."|"0"||||"0"||"1"|"S"|"1967"|"10"|"3,000"|"Recommend cleaning duct systems."|"1"|"S"|"2010"|"15"|"0"|"New thermostat added w/ furnace"|"0"|"U"|"1967"|"0"|"13,000"|"Recommend adding new fire alarm system - currently doesn't exist."|"0"|"U"|"1967"|"0"|"13,000"|"Recommend adding new smoke detection system - currently doesn't exist."|"0"||||"0"||"0"|"U"|"1967"|"0"|"9,000"|"Recommend adding emergency/exit lighting."|"0"||||"0"||"0"|"0"|"0"|"Recommend ADA compliant ramp & toilet room(s) - costs included within previous questions."|"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"|"n/a"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"1"||"FAIR"|"District is considering closing the facility & incorporating into Main Bldg."|"331,000"|"U"|"1"|"King + King Architects LLP"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|11/24/2010 1:21:50 PM| 76|"Livonia CSD"|"24080106"|"High School"|"0007"|"6/30/09"|"2 Bulldog Blvd "|"LIVONIA "|" 14487"|"ANNUAL"|"9/2011"|"1969"|"239500"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT"||"944"|"7,8,9,10,11,12"|"0"|"1"|"0"|"944"|"0"|"0"|||"42"|"33670"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"1"|"S"|"1969"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1969"|"10"|"403000"|"Replace service entrance, lateral & SWGR."|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"MUNI,SURFACEH2O"||"0"|"S"|"2007"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"662607"|"Replace existing pavement at main parking lot. Mill out 1"-1 1/2" of asphalt at seams and replace."|"1"|"CONCRETE,ASPHALT"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2010"|"15"|"61226"|"N"|"Dugouts at baseball field collect water."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"10120"|"Replace ceilings in misc. classrooms."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"S"|"2002"|"20"|"1265"|"Install closers on classroom corridor doors."|"1"|"S"|"1988"|"25"|"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"5"|"335000"|"Replace 1970 distribution."|"1"|"S"|"2007"|"15"|"587000"|"Replace various theatrical, LGI, and exterior lighting."|"1"|"1"|"S"|"2005"|"10"|"3935000"|"Replace and upgrade various systems."|"1"|"S"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"1"|"142900"|"Remove existing, and install new carpet in misc. rooms."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"15"|"58100"|"Replace VCT flooring in small cafeteria and abate flooring below."|"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"20"|"44300"|"Installation of new orchestra pit flooring system."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"CONCRETE,STEEL"|"0"|"0"||"1"|"1"|"0"|"1"|"0"||"S"|"2002"|"20"|"0"|"Water penetration problems are also related to roofing."|"1"|"MASONRY,METAL"|"S"|"1988"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"5"|"68750"|"Install new sliding unit windows with screens in the math corridor. "|"METONMET,CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"0"|"1"||"S"|"2002"|"5"|"80851"|"Replace all EPDM membrane and flashing at the perimeter edge of the existing ballasted EPDM roofing system. Furnish and install roof ladders to access all roof levels."|"1"|"PLASTIC"|"S"|"2002"|"15"|"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1988"|"15"|"75000"|"Replace underground sanitary piping."|"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"341297"|"ADA upgrades required."|"0"|"CV"|"1"|"BOILERWATE"||"S"|"1988"|"5"|"480700"|"Replace boilers and pumps. Add a summer boiler."|"1"|"S"|"1988"|"20"|"0"||"1"|"S"|"2008"|"15"|"56350"|"Computer Room A/C."|"1"|"S"|"2008"|"15"|"1292025"|"Ventilation upgrades in various areas."|"1"|"S"|"2008"|"10"|"23575"|"Replace unit heaters and add heat to Technology wing corridor."|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"54625"|"Add occupancy sensor interface and upgrade operating system."|"1"|"S"|"2007"|"15"|"98000"|"Replace remainder of existing system."|"1"|"S"|"2007"|"237000"|"0"|"Replace remainder of system."|"1"|"S"|"2008"|"2008"|"0"||"1"|"S"|"2007"|"52000"|"0"|"Expand EM and exit coverages."|"1"|"S"|"2007"|"20"|"0"||"1"|"1"|"292215"|"Renovate Boys and Girls toilet rooms for ADA compliance (near cafeteria and gym). Renovate Mens and Womens Faculty Toilet Rooms for ADA compliance (near cafeteria). Renovate Nurses area with ADA compliant toilet area."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,LIGHTING"|"FULL"||"1"||"GOOD"||"8841937"|"S"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/29/2010 10:22:21 AM| 77|"Livonia CSD"|"24080106"|"Intermediate School"|"0001"|"7/10/2009"|"2 SCHOOL ST "|"LIVONIA "|" 14487"|"ANNUAL"|"9/2011"|"1927"|"123700"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"409"|"4,5,6"|"0"|"1"|"0"|"409"|"0"|"0"|||"30"|"23232"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"15"|"57500"|"Relocate backflow preventer to exterior."|"1"|"MUN_UTILIT"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2001"|"40"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"MUNI,SURFACEH2O"||"0"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"90675"|"Replace existing pavement at south drive parking lot. "|"1"|"CONCRETE"|"S"|"2002"|"5"|"16927"|"Replace misc. concrete sidewalks."|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2009"|"4"|"54395"|"N"|"Repave existing tennis court area for multi-use area."|"RECONCRETE,OTHER"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"5200"|"Patch, repair, and paint interior wall of the auditorium. "|"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"10"|"5100"|"Lower the ceiling on the 3rd floor near the elevator to conceal the exposed ductwork."|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"S"|"2007"|"15"|"26400"|"Install closers on all classroom corridor doors. Replace corridor doors with fire rated door, glass, & lever."|"1"|"S"|"2002"|"20"|"4000"|"Install new riser covers on the stairs to the west side of the stage."|"1"|"S"|"1996"|"15"|"27800"|"Furnish and install new door frame, and or smoke guard at the elevator opening in accordance with the fire code."|"1"|"1"|"S"|"2007"|"10"|"328000"|"Replace 1920 original panels and feeders."|"1"|"S"|"2001"|"10"|"75000"|"Replace and upgrade LGI and exterior lighting."|"1"|"1"|"S"|"2001"|"10"|"2647000"|"Replace and upgrade various systems."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2002"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"MASONRY"|"0"|"0"|"Repointing required at auditorium wall."|"1"|"1"|"0"|"1"|"0"||"S"|"2002"|"5"|"91430"|"Masonry repointing required at original brick wall of the auditorium (courtyard side) Replace 25% of the facebrick & seal entire wall."|"1"|"MASONRY"|"S"|"1996"|"25"|"20413"|"Minor repointing required."|"1"|"MASONRY"|"S"|"2002"|"15"|"0"||"S"|"S"|"0"|"1"|"2007"|"5"|"26124"|"Replace misc. exterior doors. Replace existing doors, frames & hardware from the auditorium to the courtyard and auditorium to the corridor."|"1"|"S"|"2007"|"5"|"31625"|"Replace exterior stairs, railing and door at the southwest corner of the building near the Boy's Locker Room."|"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"Y"|"2002"|"10"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"1"||"S"|"2002"|"5"|"27198"|"Replace all EPDM membrane & flashing at the perimeter edge of the existing ballasted EPDM roofing system."|"1"|"PLASTIC"|"S"|"2002"|"15"|"0"||"1"|"COPPER"|"S"|"2001"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2001"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"10"|"17250"|"Add kitchen recirculation loop and pump."|"1"|"S"|"2001"|"10"|"85100"|"Replace fixtures in Locker Rooms 134A & 134B."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"10"|"46000"|"Add air conditioning in the Nurses Suite."|"1"|"S"|"2008"|"10"|"920000"|"Replace unit vents with a central VAV system."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2001"|"1725"|"0"|"Add dishwash exhaust fan to DDC."|"1"|"S"|"2001"|"10"|"109000"|"Expand existing coverage."|"1"|"S"|"2001"|"10"|"121000"|"Expand existing coverage."|"0"||||"0"||"1"|"S"|"2007"|"10"|"23000"|"Expand existing coverage."|"1"|"S"|"2001"|"25"|"81000"|"Only one ATS."|"1"|"1"|"180915"|"Provide ADA toilet and shower areas in the Boys and Girls Locker Rooms. Install an ADA accessible ramp at the northeast entrance adjacent to the elevator. Renovate the Boys and Girls Toilet Rooms to be ADA accessible near the gym."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"|"WARMING"||"1"||"GOOD"||"5075572"|"S"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/29/2010 11:58:52 AM| 78|"Livonia CSD"|"24080106"|"elementary school"|"0002"|"7/10/2009"|"6 Puppy Lane "|"LIVONIA "|" 14487"|"ANNUAL"|"9/2011"|"1955"|"109400"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"531"|"Pre-K,K,1,2,3"|"0"|"1"|"0"|"531"|"0"|"0"|||"46"|"41371"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"10"|"40250"|"Relocate backflow preventer to exterior."|"1"|"MUN_UTILIT"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"4313"|"Install new fence enclosure around the gas meter and generator."|"1"|"UTIL"|"BELOW"|"S"|"2001"|"35"|"0"||"1"|"S"|"2007"|"20"|"0"||"0"||||"0"||"1"|"S"|"1992"|"10"|"0"|"Consider replacing asphalt at Bus Drop off loop. Reset catch basins"|"1"|"S"|"2009"|"15"|"0"||"1"|"MUNI,SURFACEH2O"||"0"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"5"|"465850"|"Reconstruct paving on east side of the building (Bus Loop). "|"1"|"CONCRETE,ASPHALT"|"S"|"2007"|"10"|"20147"|"Replace misc. concrete sidewalks."|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1991"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"S"|"2007"|"5"|"43300"|"Replace existing interior vestibule doors. Replace corridor doors, and misc. hardware. Install double doors at the Custodial Storage. "|"0"||||"0"||"0"|"S"|"1955"||"25933"|"Install a vertical lift at the stage for ADA accessibility."|"1"|"1"|"S"|"2001"|"10"|"575000"|"Replace original panels."|"1"|"S"|"2001"|"10"|"236000"|"Replace T12, HID, and exterior lighting per energy audit."|"1"|"1"|"S"|"2001"|"10"|"2986000"|"Replace and upgrade various systems."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"5"|"54300"|"Replace carpet in Library, Storage Room, Office, Principals Office, and Conference Room."|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2001"|"20"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1991"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"1"|"0"|"1"|"0"||"S"|"1991"|"20"|"0"||"1"|"MASONRY"|"S"|"1991"|"10"|"5800"|"Masonry restoration on the chimney and masonry work around the building required."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"5"|"38700"|"Replace misc. exterior doors. Including the exterior door and wood frame across the corridor from the Faculty Room."|"1"|"S"|"1991"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"0"|"1"||"U"|"1991"|"1"|"1762750"|"Reroof the existing building excluding the gym roof, and the Butler building roof. This shall include replacement of the skylights."|"1"|"PLASTIC"|"U"|"1991"|"1"|"0"|"Cost associated with re-roof."|"1"|"COPPER"|"S"|"2001"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2001"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"2300"|"Upgrade kitchen hand sink."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"1991"|"5"|"230000"|"Add air conditioning to computer and data rooms."|"1"|"S"|"2001"|"5"|"1546750"|"Replace unit vents and improve ventilation."|"1"|"S"|"2001"|"10"|"55200"|"Add fin radiation at Butler wing and cabinet heaters in vestibules and corridors."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"5"|"7475"|"Upgrades in gym cafeteria and kitchen."|"1"|"S"|"2001"|"10"|"161000"|"Expand existing coverage."|"1"|"S"|"2001"|"10"|"158000"|"Expand existing coverage."|"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2001"|"15"|"52000"|"Expand existing coverage."|"1"|"S"|"2001"|"30"|"81000"|"Only one ATS."|"1"|"1"|"131523"|"Renovate Boy's and Girl's Toilet Rooms to become ADA accessible near the main entrance and gyms. Renovate Faculty toilet rooms to become ADA accessbile across from the stage."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"|"WARMING"||"1"||"GOOD"||"8557082"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/29/2010 2:27:14 PM| 79|"Livonia CSD"|"24080106"|"maintenance/bus storage"|"5009"|"8/6/2009"|"6 puppy lane"|"livonia"|" 14487"|"ANNUAL"|"9/2011"|"2002"|"6000"|"1"|"0"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Bus Maintenance and Buildings and Grounds"|"0"|||"0"|"0"||||||"0"|"0"|"ADMIN,OTHER"|"Bus Maintenance"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"S"|"2008"|"20"|"1581"|"Install new fence at gas meter."|"1"|"UTIL"|"ABOVE"|"S"|"2002"|"35"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"MUNI,SURFACEH2O"||"0"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"97911"|"Reconstruct paving in front of the building."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"25"|"2300"|"Alarm reconnection for grease separator."|"1"|"S"|"2002"|"15"|"14000"|"Upgrade lighting per energy audit."|"1"|"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"15"|"0"||"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"COMMON"|"S"|"2002"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"25"|"0"||"1"|"METAL"|"S"|"2002"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2002"|"5750"|"15"|"Replace shop area gas unit heater."|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"51750"|"Expand existing system."|"1"|"S"|"2002"|"15"|"2300"|"Expand existing coverage."|"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"156992"|"S"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-7024"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/29/2010 4:27:15 PM| 80|"Commack USFD"|"58041003"|"COMMACK MIDDLE SCHOOL"|"0027"|"02/18/2010"|"VANDERBILT PARKWAY "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1968"|"314195"|"2"|"17"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"1890"|"7,8,9"|"0"|"1"|"0"|"110"|"0"|"0"|||"110"|"65800"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,TECHSHOP"||"1"|"0"|"0"|"1"|"20000"|"E"|"2009"|"30"|"0"|"Tank was replaced."|"1"|"MUN_UTILIT"|"S"|"2008"|"23"|"0"||"1"|"SITESEPT"|"S"|"2008"|"23"|"0"||"1"|"S"|"2005"|"44"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"43"|"0"||"1"|"S"|"1968"|"15"|"0"||"0"||||"0"||"1"|"S"|"1968"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2004"|"1"|"175000"|"Pavement not done in 2004 needs to be upgraded."|"1"|"CONCRETE"|"S"|"2004"|"5"|"0"||"0"||||"0"||"1"|"S"|"2006"|"25"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2006"|"25"|"0"||"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"S"|"2006"|"25"|"0"||"1"|"S"|"2006"|"25"|"0"||"1"|"S"|"2006"|"25"|"0"||"1"|"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"8"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"8"|"0"||"0"|"COMMON"|"S"|"2006"|"15"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Cast-in-place concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2006"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"1"|"0"||"U"|"2006"|"1"|"50000"||"1"|"MASONRY"|"S"|"1968"|"1"|"45000"|"Chimney needs repointing."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2006"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"5"|"0"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"8"|"0"||"1"|"PLASTIC"|"S"|"1968"|"8"|"0"||"1"|"COPPER"|"U"|"2006"|"1"|"15000"|"Install isolation valves"|"1"|"IRON"|"S"|"2006"|"10"|"0"||"0"|||||"0"||"1"|"U"|"1968"|"1"|"50000"|"Replace leaking urinals"|"0"||"1"|"BOILERWATE"||"S"|"2005"|"34"|"0"||"1"|"S"|"2005"|"34"|"0"||"1"|"S"|"2006"|"30"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2005"|"19"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2006"|"18"|"0"||"1"|"NF"|"1968"|"1"|"100000"|"Replace generator."|"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"|"0"|"1"||"GOOD"||"$ 160,000"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|11/29/2010 5:59:51 PM| 81|"Livonia CSD"|"24080106"|"Gym and Locker Facility- Field House"|"0008"|"8/6/2009"|"2 Bulldog Blvd"|"Livonia"|"14487"|"ANNUAL"|"9/2011"|"1991"|"9113"|"2"|"0"|"0"|"DISTRICT"|"INSTRUCT"|"Wrestling, Locker Rooms, & Field House"|"0"|||"0"|"0"||||||"1"|"4000"|"OTHER"|"Wrestling "|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1991"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1991"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"OTHER"|"BELOW"|"S"|"2001"|"30"|"0"|"Fed from the High School."|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"SURFACEH2O"||"0"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"NONE"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"10"|"10201"|"Widen asphalt pavement behind the Field House."|"0"||||"0"||"1"|"S"|"2001"|"5"|"409257"|"N"|"Replace all weather track surface and event areas. Relocate discus to northeast corner of track with new fence. Replace existing fence around the perimeter of the football field in the track area."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"S"|"2001"|"5"|"8867"|"Replace interior door frames and hardware."|"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"1"|"S"|"2001"|"30"|"60"|"Need some Jbox covers."|"1"|"S"|"2001"|"15"|"39000"|"Upgrade lighting per energy audit."|"1"|"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"20"|"0"||"1"|"COMMON"|"S"|"2001"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"25"|"0"||"1"|"METAL"|"S"|"2008"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"||"U"|"2009"|"5"|"82863"|"Reroof existing building. Patches applied to roof edge to maintain water tightness in 2009."|"0"|||||"0"||"1"|"COPPER"|"S"|"1991"|"15"|"0"||"1"|"IRON"|"S"|"1991"|"20"|"0"||"1"|"OTHER"|"U"|"1991"|"3"|"40250"|"Add a gas fired heater and storage tank."|"1"|"S"|"1991"|"15"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"2002"|"5"|"62100"|"Replace upper training room unit vents."|"1"|"S"|"2002"|"5"|"32200"|"Add fin radiation & cabinet heaters."|"1"|"S"|"1991"|"15"|"0"||"1"|"S"|"2008"|"10"|"12650"|"Expand DDC system."|"1"|"S"|"2001"|"10"|"8000"|"Expand existing coverage."|"1"|"S"|"2001"|"10"|"0"||"0"|"S"|"1991"|"1991"|"0"|"There is no fire supression system in this building."|"1"|"S"|"2001"|"10"|"8000"|"Expand existing coverage."|"0"||||"0"||"1"|"1"|"40480"|"Provide ADA toilet and shower areas in Boys and Girls Team Rooms."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"698867"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/30/2010 9:58:43 AM| 82|"Livonia CSD"|"24080106"|"Concession Stand"|"2012"|"8/6/09"|"2 Bulldog Blvd"|"Livonia"|"14487"|"ANNUAL"|"9/2011"|"2002"|"1008"|"1"|"0"|"0"|"DISTRICT"|"OTHER,OTHER_ORG"|"concession building"|"0"|||"0"|"0"||||||"0"|"0"|"OTHER"|"concession stand"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"OTHER"|"BELOW"|"S"|"2002"|"20"|"0"|"Fed from field house."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"SURFACEH2O"||"0"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"||||"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"25"|"60"|"Replace coverplates."|"1"|"S"|"2002"|"15"|"1800"|"Replace exterior lights and relocate storage lights."|"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"1265"|"Misc. masonry restoration and repairs."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"2002"|"20"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Repair exterior gutter."|"S"|"2002"|"20"|"1063"|"Replace prefinished aluminum gutter on west side of building."|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"15"|"0"|"Fed from field house fire alarm control panel."|"1"|"S"|"2002"|"15"|"0"|"Fed from field house fire alarm control panel."|"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2328"|"S"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/30/2010 10:52:52 AM| 83|"Livonia CSD"|"24080106"|"Intermediate School Storage Building"|"2005"|"7/16/10"|"2 School Street"|"Livonia"|"14487"|"ANNUAL"|"9/2011"|"1950"|"552"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Storage, Field Lighting Panels"|"0"|||"0"|"0"||||||"0"|"0"|"OTHER"|"Storage & Field Lighting Panels"|"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"2004"|"15"|"0"|"Power from Intermediate School."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"1994"|"10"|"0"||"0"||||"0"||"0"||||"0"|"N"||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"15"|"0"||"1"|"S"|"1950"|"15"|"0"||"1"|"S"|"1950"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"1950"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"15"|"0"||"WOOD"|"0"|"1"||"1"|"1"|"0"|"1"|"1"||"U"|"1950"|"34155"|"0"|"Replace exterior skin of building with new siding."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1950"|"5"|"5060"|"Replace existing doors in the front and rear of the building."|"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1950"|"5"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"18"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|||"POOR"||"POOR"||"0"|"0"|"FAIR"||"DAYLIGHT,INCANDESCE"|"FAIR"||"1"|"1"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"FAIR"||"1"|"0"|"0"|"1"|"1"|"0"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"POOR"||"39215"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville New York 14221"|"716-633-9000"|"mike@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|11/30/2010 1:38:47 PM| 84|"BOCES Madison-Oneida"|"25900000"|"Rossetti Center/ Alternative High School"|"0002"|"08/31/2010"|"SPRING ROAD "|"VERONA "|" 13478"|"ANNUAL"|"08/15/2011"|"1969"|"192350"|"2"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"192350"|"9,10,11,12"|"0"|"1"|"1"|"57"|"0"|"0"|||"57"|"91200"|"ADMIN,AV,AUDITORIUM,COMPROOM,GUIDANCE,HOMECAREER,KITCHEN,LGGROUP,MULTIPURPO,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"SITESEPT"|"S"|"2002"|"16"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"|"need to be sealed"|"1"|"CONCRETE"|"S"|"2002"|"20"|"0"|"a few of the older areas need repair"|"1"|"S"|"2002"|"6"|"0"|"Some fastner bolts rusted"|"0"|"S"|"2002"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"16"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"16"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"S"|"2002"|"22"|"0"||"1"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"1"|"S"|"2002"|"12"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"8"|"0"||"1"|"COMMON"|"S"|"2002"|"18"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"14"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"|"no"|"0"|"0"|"0"|"0"|"0"|"no"|"S"|"2002"|"12"|"0"||"1"|"METAL"|"S"|"2002"|"16"|"0"||"1"|"METAL"|"S"|"2002"|"16"|"0"||"S"|"S"|"0"|"1"|"2002"|"10"|"0"|"need to continue to evaluate and install new locks and access control."|"1"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"no"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"no"|"S"|"2010"|"5"|"0"||"1"|"GLASS"|"E"|"2010"|"15"|"0"||"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"9"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"CV,VAV,DD_MZ,OTHER"|"1"|"BOILERWATE,OTHER"|"Cogeneration"|"S"|"2007"|"12"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"S"|"2002"|"16"|"0"||"1"|"S"|"2002"|"17"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"14"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2007"|"12"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"|"1"|"GOOD"||"150,000.00"|"S"|"1"|"William Murphy CO"|"303 E Noyes BLVD"|"315-363-3682"|"murphy@twcny.rr.com"|"William Murphy"|"041779"|"I accept"|11/30/2010 3:21:59 PM| 88|"Brewster CSD"|"48060106"|"Administration Building"|"1005"|"08/10/2010"|"30 Farm to Market Rd."|"Brewster,NY"|" 10509"|"ANNUAL"|"05/01/2011"|"1971"|"6800"|"2"|"2"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||||"1"|"WELL"|"S"|"1971"|"10"||"System originates from HH Wells MS"|"1"|"MUN_UTILIT"|"S"|"1971"|"10"|||"0"||||||"1"|"UTIL"|"BELOW"|"S"|"1985"|"25"|||"1"|"S"|"1971"|"10"|||"0"||||||"1"|"S"|"1971"|"10"|||"0"||||||"0"|||||||||"0"||||||"0"||||||"0"||||||"0"||||||"1"|"ASPHALT"|"S"|"2001"|"7"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2001"|"7"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"10"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1971"|"2"|"10600"|"Recommend ADA hardware allowance"|"1"|"S"|"1971"|"15"|"2800"|"Replace railing to meet current code - height 42" and 4" maximum opening"|"0"||||"0"||"1"|"1"|"S"|"1971"|"0"|"30000"|"Switch board is beyond useful life"|"1"|"S"|"2005"|"15"|"0"||"1"|"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"6"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"20"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"CONCRMETAL,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"10"|"0"||"1"|"METAL"|"S"|"1971"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2008"|"15"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"10"|"10000"|"Provide RPZ backflow preventer"|"1"|"IRON,COPPER"|"S"|"1971"|"10"|"0"||"1"|"ELECTRIC"|"S"|"2010"|"10"|"0"||"1"|"S"|"2001"|"30"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2001"|"6"|"0"||"1"|"S"|"1971"|"8"|"0"||"1"|"S"|"2001"|"6"|"1000"|"Replace damaged insulation on split system refrigerant piping"|"1"|"S"|"1971"|"0"|"10000"|"Replace indoor air handling unit"|"0"||||"0"||"1"|"S"|"1971"|"11"|"0"||"1"|"S"|"2001"|"6"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"|"Tied into Bus Barn generator"|"1"|"0"|"150000"|"No elevator to lower level, no accessible restrooms on office level - cost to add elevator"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"1"|"1"|"0"|"0"||"0"|"0"|"0"|||"0"|"1"|"COMMSYS,FIREALARM,LIGHTING"||"0"|"1"||"FAIR"|"Overcrowded"|"214400"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"rdavidson@kgdarchitects.com"|"Russell A. Davidson, AIA"|"019885"|"I ACCEPT"|11/30/2010 5:32:34 PM| 89|"BOCES Eastern Suffolk"|"58910000"|"Colin Drive Support Center"|"1088"|"10/19/2010"|"90-9B Colin Drive"|"Holbrook"|" 11741"|"ANNUAL"|"05/01/2011"|"1992"|"6000"|"1"|"2"|"0"|"LSD_DIST"|"OTHER"|"Operations and Maintenance Department"|"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"1"|"0"|"0"|"1"|"2000"|"S"|"1992"|"9"|"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"13"|"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"13"|"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"9"|"0"||"1"|"S"|"1992"|"14"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1992"|"4"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1992"|"4"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"13"|"0"||"1"|"S"|"1992"|"13"|"0"||"1"|"S"|"2002"|"8"|"0"||"1"|"S"|"2002"|"8"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"7"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1992"|"8"|"0"||"1"|"S"|"2002"|"8"|"0"||"1"|"1"|"S"|"2002"|"3"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"8"|"0"||"1"|"COMMON"|"S"|"2002"|"8"|"0"||"1"|"COMMON"|"S"|"2002"|"8"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"14"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"14"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"7"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1992"|"7"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"6"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1992"|"8"|"0"||"1"|"IRON,PVC"|"S"|"1992"|"8"|"0"||"1"|"ELECTRIC"|"S"|"1992"|"3"|"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"OTHER"|"1"|"FURNACE"||"S"|"1992"|"8"|"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"S"|"1992"|"8"|"0"||"0"||||"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"S"|"1992"|"8"|"0"||"0"|"NF"|||"0"||"0"|"NF"|||"0"||"1"|"S"|"1992"|"1992"|"0"||"1"|"S"|"1992"|"8"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"0"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|11/30/2010 7:53:13 PM| 92|"BOCES Eastern Suffolk"|"58910000"|"James Hines Administration"|"1039"|"10/19/2010"|"201 Sunrise Highway"|"Patchogue"|" 11772"|"ANNUAL"|"05/01/2011"|"1963"|"34700"|"2"|"4"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"1"|"0"|"0"|"2"|"6000"|"S"|"2003"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"5"|"0"||"1"|"SITESEPT"|"S"|"1963"|"5"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1971"|"13"|"0"||"1"|"S"|"1963"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1971"|"1"|"85,000"|"Repave, reseal, and restripe parking areas and driveways."|"1"|"CONCRETE"|"S"|"2009"|"7"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"1997"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1971"|"5"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"U"|"2006"|"1"|"4,500"|"Upgrade elevator telephone to comply with ASME."|"1"|"1"|"S"|"1971"|"5"|"0"||"1"|"S"|"2006"|"6"|"0"||"1"|"1"|"S"|"2007"|"8"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1997"|"1"|"14,420"|"Replace carpet in Programmer's Office and Lower Level Hall."|"1"|"COMMON"|"S"|"1997"|"5"|"0"||"1"|"COMMON"|"S"|"1997"|"5"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"15"|"2,000"|"Repair soffit at Main Entrance."|"1"|"MASONRY"|"S"|"2005"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"5"|"0"||"1"|"S"|"1971"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1971"|"5"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1997"|"10"|"0"||"1"|"PLASTIC"|"S"|"1997"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1971"|"15"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1971"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2003"|"2"|"0"||"1"|"S"|"1971"|"2"|"0"||"1"|"OTHER"|"0"|"BOILERWATE"||"S"|"2006"|"11"|"0"||"1"|"S"|"2003"|"5"|"0"||"1"|"U"|"1997"|"1"|"206,000"|"Upgrade System in 1971 Wing on the West Side."|"1"|"S"|"1997"|"5"|"0"||"1"|"S"|"2003"|"5"|"0"||"1"|"U"|"1997"|"1"|"51,500"|"Upgrade as needed in time with A/C upgrade."|"1"|"S"|"2006"|"11"|"0"||"1"|"S"|"1997"|"5"|"0"||"1"|"S"|"1997"|"5"|"0"||"0"||||"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"363,420"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/1/2010 1:44:19 PM| 98|"BOCES Eastern Suffolk"|"58910000"|"Roanoke Avenue Office"|"1034"|"11/04/2010"|"969 Roanoke Avenue"|"Riverhead"|" 11901"|"ANNUAL"|"05/01/2011"|"1920"|"8400"|"2"|"1"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1992"|"5"|"0"||"1"|"U"|"1992"|"1"|"15,000"|"Add drainage at low area where it gets flooded."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"12"|"10,000"|"Repair pavement around back drain."|"1"|"CONCRETE"|"S"|"1992"|"1"|"6,000"|"Renovate to make sidewalks leveled."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1920"|"5"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"5"|"0"||"1"|"S"|"1992"|"5"|"0"||"0"||||"0"||"1"|"1"|"S"|"1992"|"5"|"0"||"1"|"S"|"1992"|"5"|"0"||"1"|"1"|"S"|"1992"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1992"|"5"|"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1992"|"5"|"0"||"1"|"COMMON"|"S"|"1992"|"5"|"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"15"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"U"|"1992"|"1"|"5,200"|"Wood shakes need to be refurbished."|"1"|"MASONRY"|"S"|"1992"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"5"|"0"||"1"|"S"|"2007"|"2"|"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1992"|"5"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"2"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1992"|"5"|"0"||"1"|"IRON,PVC"|"S"|"1992"|"5"|"0"||"1"|"NAT_GAS"|"S"|"1992"|"2"|"0"||"1"|"S"|"1992"|"5"|"0"||"0"||"1"|"BOILERWATE"||"U"|"1920"|"1"|"41,200"|"Replace Boiler"|"1"|"U"|"1920"|"1"|"5,100"|"Upgrade with new boiler."|"0"||||"0"||"0"||||"0"||"1"|"S"|"1992"|"5"|"0"||"0"||||"0"||"1"|"S"|"1992"|"5"|"0"||"1"|"U"|"1998"|"1"|"20,600"|"Upgrade to comply with ADA regulations."|"1"|"U"|"1998"|"1"|"1,500"|"Upgrade with Fire Alarm System."|"0"||||"0"||"1"|"S"|"1998"|"5"|"0"||"0"||||"0"||"1"|"0"|"82,400"||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||"0"||"0"|"0"||||"1"||"GOOD"||"187,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/1/2010 3:47:08 PM| 100|"BOCES Eastern Suffolk"|"58910000"|"Ed Comm/Library Riverhead"|"1029"|"11/03/2010"|"974 N. Griffing Avenue"|"Riverhead"|" 11901"|"ANNUAL"|"05/01/2011"|"1990"|"1820"|"1"|"6"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"5"|"0"||"1"|"U"|"1990"|"1"|"0"|"See Central Bldg.#1 for upgrading of entire campus."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1990"|"1"|"0"|"See Central Bldg.#1 for upgrading of Entire Campus."|"1"|"CONCRETE"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"15"|"0"||"1"|"S"|"2008"|"5"|"0"||"1"|"U"|"2008"|"1"|"1,500"|"Roof leaks damage was not repaired."|"1"|"U"|"1990"|"1"|"2,000"|"Repair damaged ceilings from leaks in roof."|"0"||||"0"||"1"|"S"|"S"|"1990"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"2004"|"5"|"0"||"1"|"1"|"S"|"1998"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"8"|"0"||"1"|"COMMON"|"S"|"2008"|"8"|"0"||"1"|"COMMON"|"S"|"2008"|"8"|"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"15"|"0"||"WOOD,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"5"|"0"||"1"|"U"|"1990"|"1"|"5,000"|"Cracks in ramp need repairs."|"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1990"|"5"|"0"||"WOODONWOOD"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"U"|"1990"|"1"|"2,600"|"Repair Roof Leaks."|"1"|"PLASTIC"|"S"|"1990"|"10"|"0"||"1"|"COPPER"|"S"|"1990"|"5"|"0"||"1"|"GALVANIZED,PVC"|"S"|"1990"|"5"|"0"||"1"|"ELECTRIC"|"S"|"1990"|"2"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"||"1"|"OTHER"|"PTAC Units"|"U"|"2006"|"1"|"56,500"|"Replace 10 PTAC Units."|"1"|"S"|"2006"|"5"|"0"||"1"|"U"|"2006"|"1"|"0"|"Will be part of the 10 PTAC units to be replaced."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"U"|"1990"|"1"|"0"|"To be replaced with new PTAC units."|"1"|"U"|"1998"|"1"|"4,200"|"Upgrade to comply with ADA installing strobe lights."|"1"|"U"|"1998"|"1"|"600"|"To be replaced as part of Fire Alarm System upgrade."|"0"||||"0"||"1"|"S"|"1998"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"72,400"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/1/2010 5:38:07 PM| 101|"BOCES Eastern Suffolk"|"58910000"|"Special Ed Support Services-WHB"|"1018"|"10/26/2010"|"215 Old Riverhead Road"|"Westhampton Beach"|" 11978"|"ANNUAL"|"05/01/2011"|"1978"|"1500"|"1"|"8"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1978"|"5"|"0"||"1"|"SITESEPT"|"S"|"1978"|"5"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"U"|"2001"|"1"|"0"|"See Special Ed Center for common paving."|"1"|"CONCRETE"|"S"|"1978"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1978"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"2005"|"5"|"0"||"1"|"1"|"S"|"1980"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1978"|"5"|"0"||"1"|"COMMON"|"S"|"1978"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1978"|"5"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1978"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1978"|"1"|"3,000"|"Replace Main Entrance doors with FRP doors."|"1"|"S"|"1978"|"5"|"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1978"|"5"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1978"|"5"|"0"||"0"|||||"0"||"1"|"COPPER,OTHER"|"S"|"1978"|"5"|"0"||"1"|"PVC"|"S"|"1978"|"5"|"0"||"1"|"ELECTRIC"|"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"OTHER"|"1"|"FURNACE"||"S"|"2000"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"2000"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"2005"|"5"|"0"||"1"|"S"|"2005"|"5"|"0"||"0"||||"0"||"1"|"S"|"2005"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"3,000"|"S"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/1/2010 6:58:42 PM| 103|"BOCES Madison-Oneida"|"25900000"|"BROAD STREET LEARNING CENTER "|"8036"|"09/06/2010"|"585 BROAD STREET "|"ONEIDA "|" 13421"|"ANNUAL"|"08/15/2011"|"1982"|"1860"|"1"|"0"|"1"|"LSD_DIST"|"INSTRUCT"||"22"|"9,10,11,12"|"0"|"1"|"0"|"1"|"0"|"0"|||"1"|"1200"|"ADMIN,COMPROOM,GUIDANCE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1982"|"6"|"0"||"1"|"MUN_UTILIT"|"S"|"1982"|"6"|"0"||"1"|"S"|"1982"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1982"|"6"|"0"||"1"|"S"|"1982"|"10"|"0"||"0"||||"0"||"0"|"S"|"1982"|"6"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1982"|"5"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1982"|"10"|"0"||"0"||||"0"||"1"|"S"|"1982"|"6"|"0"||"1"|"S"|"1982"|"6"|"0"||"0"||||"0"||"1"|"S"|"S"|"1982"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1982"|"10"|"0"||"1"|"S"|"1982"|"6"|"0"||"0"|||||"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"4"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"2"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1982"|"6"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1982"|"10"|"0"||"1"|"METAL"|"S"|"1982"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1982"|"5"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1982"|"6"|"0"||"WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1982"|"6"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1982"|"6"|"0"||"1"|"IRON,COPPER"|"S"|"1982"|"6"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"6"|"0"||"1"|"S"|"1995"|"6"|"0"||"1"|"OTHER"|"1"|"FURNACE"||"S"|"1995"|"4"|"0"||"0"||||"0"||"1"|"S"|"1995"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1995"|"6"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"|"1"|"6000"||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"30000"|"S"|"1"|"William J Murphy CO"|"303 E Noyes BLVD"|"315-363-3682"|"murphy@twcny.rr.com"|"William J.Murphy"|"041799"|"I accept"|12/2/2010 1:29:32 PM| 104|"North Warren CSD"|"63020204"|"NEW K-12 BUILDING"|"0014"|"09/29/2010"|"6110 State Route 8"|"CHESTERTOWN "|"12817-2417"|"ANNUAL"|"01/01/2011"|"1998"|"148775"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER"||"560"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"560"|"0"|"0"|"CAFE,LIB"||"53"|"36540"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED"||"1"|"0"|"0"|"1"|"20000"|"S"|"2010"|"15"|"0"|"Monitoring system replaced in 2010."|"1"|"WELL"|"S"|"2007"|"15"|"0"|"Backflow preventer replaced in 2007"|"1"|"SITESEPT"|"S"|"2009"|"15"|"0"|"Pumped system, fields replaced due to failure of original field."|"1"|"S"|"1998"|"15"|"0"|"Underground tank for kitchen, small above ground tank for science classroom."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"|"Paving and roof surfaces drain to the closed system. Athletic fields drain to open system. Some erosion at pedestrian bridge to fields due to runoff from walk. Recommend modifying walk to divert water before the bridge."|"1"|"S"|"1998"|"15"|"0"|"Some of the top frames of the catch basins are settling. Rebuild to raise frame and grate."|"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1998"|"10"|"0"|"All collected stormwater goes to infiltration beds. Beds seem to be working, but may contribute to apparent groundwater moisture problems in building."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"0"|"Good condition, but some cracks larger than might be expected. Cracks are sealed, as they should be. May be indication of subsurface water problem."|"1"|"CONCRETE,ASPHALT"|"S"|"1998"|"15"|"0"|"Some laitance (surface spalling) behind northeast wing. This is probably a result of too much water in concrete when placed. Will probably not deteriorate beyond surface spalling. If remedial action desired, replacement of affected slabs recommended."|"1"|"S"|"1998"|"10"|"0"|"Creative playground. Treated wood components should be sealed."|"1"|"S"|"1998"|"15"|"0"|"N"|"Some localized drainage concerns - may be perched water below surface. Pedestrian and vehicle bridges on site. Moisture problem at tennis courts - may be ground water working up through asphalt. Posts at nets heaving, need replacement."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"S"|"1998"|"15"|"9000"|"Non-structural wall cracks. Some cracks visible in CSE Office, corridor near rooms B129 and B131. Appear to be movement related, not structural. Repair to allow movement."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"1"|"S"|"1998"|"4"|"254000"|"Clock/telephone/Intercom will require replacement/upgrade."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"4"|"17000"|"Replace office carpeting with neoprene backed product. Appears to be under slab moisture problem."|"1"|"INSTRUCT,COMMON"|"S"|"1998"|"10"|"4000"|"Vinyl composition tile typical, sheet rubber in Elementary Gym (needs lines repainted); interlocking rubber tile in some corridors."|"1"|"INSTRUCT,COMMON"|"S"|"1998"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1998"|"15"|"32000"|"Consider sanding and refinishing in next 5 years. Note bleacher wheels need replacement - marring floor finish."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"15"|"0"|"Steel structure has spray on fire proofing."|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"15"|"0"||"1"|"MASONRY"|"S"|"1998"|"15"|"0"||"1"|"MASONRY"|"S"|"1998"|"15"|"0"||"S"|"S"|"0"|"1"|"1998"|"15"|"0"|"FRP and aluminum doors systems"|"0"||||"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"Y"|"1998"|"15"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Roofing near end of useful life"|"S"|"1998"|"0"|"1182000"|"Hypalon roofing has been recoated under warranty due to surface deterioration, but is near end of life. Coating is now peeling up in several areas. Limited areas have had roofing membrane recovered with new membrane."|"1"|"GLASS"|"S"|"1998"|"10"|"0"|"Located in atrium at main entrance. Have had some problem with leaks, seal of thermal pane glass failing."|"1"|"COPPER"|"S"|"1998"|"15"|"9000"|"Restore softening system operation."|"1"|"IRON,COPPER"|"S"|"1998"|"15"|"0"||"1"|"OIL"|"S"|"2007"|"15"|"43000"|"One of two heaters has failed and needs to be replaced. Recommend switching to boilers for water heating."|"1"|"U"|"1998"|"4"|"85000"|"Trim, valves and watercoolers in poor condition."|"0"||"1"|"BOILERWATE"||"S"|"1998"|"4"|"507000"|"Reaching life expectancy."|"1"|"S"|"1998"|"4"|"17000"|"Replace oil pump set."|"1"|"S"|"2005"|"4"|"102000"|"Install split system, ductless units in place of central systems in offices and computer classrooms."|"1"|"S"|"2005"|"15"|"0"|"Air conditioning has been added to the auditorium."|"1"|"S"|"1998"|"4"|"169000"|"Need to replace heating isolation valves and control valves."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"4"|"338000"|"System is being phased out by manufacturer."|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"1998"|"0"|"Ansul system for hood."|"1"|"S"|"1998"|"4"|"17000"|"Exit light battery/chargers failing. Should be replaced immediately."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"Auditorium acoustics are reported to be poor."|"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||"FULL"|"0"|"0"|"0"|"FAIR"||"1603000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/2/2010 3:17:41 PM| 107|"Commack USFD"|"58041003"|"HUBBS ADMINISTRATION CENTER"|"1015"|"03/30/2010"|"CLAY PITTS ROAD "|"EAST NORTHPORT "|" 11725"|"ANNUAL"|"05/01/2011"|"1964"|"35000"|"2"|"2"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"10000"|"E"|"2005"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"2"|"0"||"1"|"SITESEPT"|"S"|"1964"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1964"|"5"|"0"||"1"|"S"|"1964"|"15"|"0"||"0"|"S"|||"0"||"1"|"S"|"1964"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1964"|"1"|"10000"|"Rear parking area "|"1"|"CONCRETE"|"U"|"1982"|"1"|"120000"|"Replace original walks not replaced in 1982."|"0"||||"0"||"1"|"S"|"1964"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"25"|"0"||"1"|"S"|"1964"|"25"|"0"||"1"|"S"|"1964"|"25"|"0"||"1"|"S"|"1980"|"5"|"0"||"0"||||"0"||"1"|"U"|"U"|"1964"|"1"|"55000"|"Upgrade original doors as needed."|"1"|"S"|"1964"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1964"|"5"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"20"|"0"||"1"|"COMMON"|"S"|"2009"|"25"|"0"||"1"|"COMMON"|"S"|"2009"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"25"|"0"||"1"|"MASONRY"|"U"|"1964"|"1"|"20000"|"Repoint chimney brick."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"0"||"1"|"S"|"1964"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"25"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"1983"|"1"|"380000"|"Replace aging roof."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1964"|"5"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1964"|"5"|"0"||"1"|"OIL"|"S"|"1964"|"5"|"0"|"It is a hot water tank."|"1"|"S"|"1964"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2010"|"20"|"0"||"1"|"S"|"1964"|"5"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"1964"|"5"|"0"||"1"|"U"|"1964"|"1"|"10000"|"Replace rooftop ductwork insulation."|"1"|"U"|"1964"|"1"|"50000"|"Provide DDC head end controller and perform pneumatic refurbishment."|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"1964"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"|||"0"|"0"|"0"||"WARMING"|"0"|"1"|"0"|"GOOD"||"$ 638,000"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/2/2010 6:38:36 PM| 109|"North Warren CSD"|"63020204"|"Small Storage Facility "|"2018"|"09/29/2010"|"6110 State Route 8"|"CHESTERTOWN"|"12817"|"ANNUAL"|"01/01/2011"|"2003"|"2400"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Storage"|"0"|||"0"|"0"||||||"0"|"0"|||"1"|"1"|"275"|"0"|"0"|"S"|"2010"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2003"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2003"|"15"|"0"|"Exposed concrete slab."|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"15"|"0"||"MASONRY,STEEL,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"|"Wood framing, with brick veneer and steel siding."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"1"|"FURNACE"||"S"|"2003"|"10"|"0"||"0"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"|"Zoned system"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"|"0"|"0"|"Gravel lot prevents acceptable access. Per NYS Building Code - utility building are exempt from this requirement."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"FAIR"|"Above items A, B, C, D, E, F, G, H, and I, do not apply for this facility."|"1"||"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/3/2010 8:43:12 AM| 110|"Sherrill City SD"|"41200005"|"Tilden Hill Triplexus"|"0012"|"09/03/2010"|"TILDEN HILL RD "|"VERONA "|" 13478"|"ANNUAL"|"08/15/2011"|"1993"|"39000"|"2"|"1"|"0"|"LSD_DIST"|"INSTRUCT,OTHER"|"Meeting areas"|"165"|"5,6,7,8"|"0"|"1"|"0"|"57"|"0"|"0"|||"57"|"18000"|"ADMIN,ART,AV,COMPROOM,GUIDANCE,MULTIPURPO,RSRCEROOM,SCIENCELAB,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"SITESEPT"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"UTIL,SELF"|"ABOVE"|"S"|"2007"|"20"|"0"|"New cogen plant"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"|"sand bed with SPEDES permit"|"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"8"|"0"||"0"|"CONCRETE"|"S"|"2002"|"9"|"0"||"1"|"S"|"1996"|"2"|"0"||"1"|"S"|"2002"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"7"|"0"|"In 2002 some rooms have had new ceiling placed in them. some rooms still need to be updated."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"S"|"2002"|"10"|"0"|"In 2002 some doors were replaced. We continue to replaced as needed"|"1"|"S"|"1993"|"20"|"0"|"Stairs are to a second story machanical space."|"0"||||"0"||"1"|"1"|"S"|"2006"|"20"|"0"|"In 2006 we replace our cogen unit along with some electrical distribution."|"1"|"S"|"2002"|"10"|"0"|"All lighting is t-8 277v"|"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"15000"|"in 2002 new carpet was replace in some areas. new carpet is needed in the rest of the building."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"10000"|"Many small/medium sized cracks@ outside walls. Will require repair . Little evidence of wall penitration."|"1"|"METAL"|"S"|"2002"|"20"|"0"||"1"|"MASONRY"|"S"|"1993"|"10"|"0"||"S"|"S"|"0"|"0"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1"|"2006"|"10"|"0"|"Cogen exit door. Jombi Ladder system"|"1"|"ALUMINUM"|"S"|"Y"|"2002"|"11"|"0"||"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"8"|"0"||"1"|"PLASTIC"|"S"|"1993"|"8"|"0"||"1"|"COPPER"|"S"|"2002"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1993"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2007"|"15"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"OTHER"|"1"|"BOILERWATE,OTHER"|"Cogeneration"|"S"|"2007"|"10"|"0"|"New cogeration system was installed and many new componets were installed."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"2007"|"15"|"0"|"A new cogeneration sysytem was installed and many parts of the old system were replaced"|"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"|"a new cogen system was installed and upgraded the operating system."|"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"2007"|"2007"|"0"|"A spinkler system was installed on the second floor of the cogen room durrin g the cogen project."|"1"|"S"|"2002"|"14"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"|"INACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"0"|"0"|"1"|"GOOD"||"40000"|"S"|"1"|"Wiliam J. Murphy CO."|"303 E. Noyes BLVD"|"315-363-3682"|"murphy@twcny.rr.com"|"William J. Murphy"|"041799"|"I accept"|12/3/2010 8:58:20 AM| 111|"Laurens CSD"|"47080104"|"BUS GARAGE"|"5011"|"08/24/2010"|"69 MAIN STREET"|"LAURENS"|" 13796"|"ANNUAL"|"12/01/2010"|"1990"|"2880"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Transportation/Storage"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"2"|"410"|"3"|"9500"|"S"|"1990"|"10"|"0"|"Above:135 motor oil/275 waste oil/6000 diesel; Below:1000 gas/2500 fuel oil"|"1"|"WELL"|"U"|"1990"|"5"|"17,000"|"Provide drilled well for potable water."|"1"|"SITESEPT"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1990"|"20"|"0"||"0"||||"0"||"1"|"U"|"1990"|"5"|"310,000"|"Replace storm water management system (comply w/ NYDEC)."|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"U"|"1990"|"5"|"580,000"|"Recommend replacing asphalt. It's in poor condition."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"20"|"0"|"Steel stairs to parts storage mezzanine."|"1"|"S"|"1990"|"20"|"0"|"Routine inspection & maintenance on vehicle lifts."|"1"|"1"|"U"|"1990"|"5"|"18,000"|"Recommend adding sub-distribution panel for added circuits, currently no expansion space."|"1"|"U"|"1990"|"5"|"35,000"|"Recommend replacing T-12 lighting."|"1"|"1"|"U"|"1990"|"5"|"26,000"|"Recommend updating communications system"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1990"|"10"|"0"||"1"|"COMMON"|"S"|"1990"|"25"|"0"||"1"|"COMMON"|"S"|"1990"|"15"|"0"|"mezzanine (parts/storage)"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"|"minor settlement cracks (normal)"|"1"|"0"|"0"|"S"|"1990"|"20"|"0"||"STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"10"|"0"||"1"|"METAL"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"5"|"7,000"|"New overhead doors. Recommend replacing (2) 3'-0" doors"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"NA"|"1990"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1990"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"20"|"0"||"1"|"ELECTRIC"|"U"|"1990"|"5"|"9,000"|"Replace heater in kind."|"1"|"U"|"1990"|"5"|"2,000"|"Recommend replacing faucets & flush tank mechanisms."|"0"||"1"|"FURNACE"||"S"|"1990"|"10"|"0"|"Oil-fired unit heaters & electric fin."|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2000"|"5"|"0"|"Window A/C unit"|"1"|"S"|"1990"|"5"|"0"|"Toilet exhaust adequate."|"1"|"S"|"1990"|"10"|"0"|"Oil piping to unit heaters is adequate."|"1"|"S"|"1990"|"10"|"0"|"Toilet exhaust acceptable."|"1"|"U"|"1990"|"5"|"35,000"|"Recommend CO2 system for bus bay."|"1"|"U"|"1990"|"5"|"26,000"|"Recommend adding new fire alarm system. "|"1"|"U"|"1990"|"5"|"26,000"|"Recommend adding new smoke detection system."|"0"||||"0"||"1"|"U"|"1990"|"5"|"18,000"|"Recommend adding emergency lights."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"1,109,000"|"U"|"1"|"King + King Architects LLP"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/3/2010 9:44:08 AM| 113|"North Warren CSD"|"63020204"|"Bus Garage/Transportation"|"5017"|"09/29/2010"|"RT 8 "|"CHESTERTOWN "|"12817-2417"|"ANNUAL"|"01/01/2011"|"1999"|"3360"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Transportation facility"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"1"|"275"|"0"|"0"|"S"|"1999"|"15"|"0"|"Heating fuel only - buses are fueled at county facility."|"1"|"WELL"|"S"|"1999"|"15"|"0"||"1"|"SITESEPT"|"S"|"1999"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Oil separator has been cleaned and kept operating properly."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"15"|"5000"|"Widen paving around side of garage - tires run off existing paving."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"15"|"0"|"Foundation walls not visible - covered by insulation with stucco finish. No apparent movement of foundation."|"1"|"S"|"1999"|"15"|"0"|"Masonry bearing walls for mezzanine."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Stairs to mezzanine."|"0"||||"0"||"1"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1999"|"10"|"0"||"1"|"COMMON"|"S"|"1999"|"15"|"0"|"Exposed concrete floor slab"|"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"15"|"0"|"Slab on grade with radiant heating. Small raised mezzanine floor area."|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"15"|"0"||"1"|"METAL"|"S"|"1999"|"15"|"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1999"|"15"|"6000"|"Replace badly rusted side door."|"0"||||"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"NA"|"1999"|"15"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"15"|"0"|"Standing seam metal roofing. Roofing panels serve as decking also (no separate decking)."|"0"|||||"0"||"1"|"COPPER"|"S"|"1999"|"15"|"0"||"1"|"IRON"|"S"|"1999"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2008"|"10"|"0"|"Heater has been replaced."|"1"|"S"|"1999"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1999"|"15"|"21000"|"Replace entire plant and incorporate glycol into radiant floor heating system."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"|"Window units"|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"15"|"0"|"Radiant floor through out"|"0"||||"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"|"Consider adding generator as back up to keep radiant floor system from freezing (see also above to change to glycol hydronic system)."|"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,OTHER,NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Above item H is does not apply for this facility."|"1"||"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"116000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/3/2010 10:27:03 AM| 114|"BOCES Wayne-Finger Lakes"|"43900000"|"FLTCC - Early Childhood Education"|"8030"|"09/23/2010"|"3501 County Road 20"|"Stanley"|" 14561"|"ANNUAL"|"08/01/2011"|"1990"|"7000"|"1"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"34"|"9,10,11,12"|"0"|"0"|"0"|"34"|"0"|"0"|||"6"|"5000"|"ADMIN,KITCHEN,PREK"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"SITESEPT"|"S"|"1993"|"40"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"E"|"2005"|"30"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"60"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1900"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1990"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"1"|"1"|"S"|"1990"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"50"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1990"|"20"|"0"||"WOODONWOOD,WOODONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1990"|"25"|"0"||"1"|"IRON,PVC"|"S"|"1990"|"25"|"0"||"1"|"ELECTRIC"|"S"|"2005"|"10"|"9000"|"Not ASME, provide electric tank type ASME water heater."|"1"|"S"|"1990"|"15"|"12800"|"Replace fixture trim. Replace flush valves and faucets with sensor type (typical of 16)."|"0"||"1"|"OTHER"||"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"210000"|"Provide air conditioning/no ventilation and electric PTAC units."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"1"|"1"|"1"|"0"|"1"|"0"|"0"||||"1"||"FAIR"||"285000"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Steven F. Moolin, R.A."|"021568"|"I ACCEPT"|12/3/2010 11:17:08 AM| 116|"Hammondsport CSD"|"57290104"|"NEW BUS GARAGE "|"0002"|"07/29/2010"|"8272 MAIN STREET "|"HAMMONDSPORT "|" 14840"|"ANNUAL"|"05/11/2011"|"1956"|"98410"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"462"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"462"|"0"|"1"|"OTHER"|"AUDITORIUM"|"33"|"19026"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"0"|"0"|"2"|"10000"|"S"|"1988"|"10"|"0"|"single wall, fiberglass, no cathode protection"|"1"|"MUN_UTILIT"|"E"|"2000"|"20"|"0"||"1"|"SITESEPT"|"S"|"1988"|"8"|"40000"|"sand replacment required for beds (2) 60'X60'X5' deep"|"1"|"S"|"1980"|"15"|"0"|"natural gas"|"1"|"UTIL"|"BELOW"|"E"|"1988"|"30"|"0"|"on-site emergency generator added 2006, NYSEG"|"1"|"S"|"2000"|"15"|"0"|"athletic field replaced"|"1"|"S"|"1988"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"OTHER"|"unknown"|"1"|"S"|"1988"|"0"|"0"|"don't have info for this"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"5"|"750000"|"except for 2007 bus loop reconstruction the asphalt is in poor condition"|"1"|"CONCRETE"|"S"|"2007"|"15"|"0"||"1"|"S"|"1988"|"10"|"35000"|"modifications and additional equipment for ADA compliance"|"1"|"S"|"2000,2007"|"20"|"0"|"N"|"2000 fileds 2007 track"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"15"|"5000"|"northeast corner @ loading dock foundation needs repair"|"1"|"U"|"2000"|"15"|"2500"|"kitchen and cafeteria require fire rated construction and opening protectives"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"5"|"15000"|"replace water damaged andphysically damaged ceiling tiles"|"1"|"E"|"2004"|"15"|"0"|"replace 9" lockers with 12" or 15" lockers"|"1"|"U"|"U"|"2000"|"10"|"375000"|"original doors and frames should be refinished or replaced-doors, hardware and configuration are not ADA"|"1"|"U"|"2000"|"20"|"420000"|"stair doors are not fire rated or ADA compliant and should be reconfigured"|"1"|"S"|"2000"|"15"|"0"||"1"|"1"|"S"|"2000"|"30"|"85000"|"some distribution remians from 1957"|"1"|"S"|"2001"|"15"|"0"|"all T-8 fixtures"|"1"|"1"|"U"|"2005"|"25"|"45000"|"PA system should be replaced"|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"15"|"0"||"1"|"INSTRUCT"|"U"|"1969"|"5"|"200000"|"69 spaces currently have vinyl asbestos tiles that s hould be abated and replaced. industrial arts wing has a mixture or vinyl flooring and wood flooring that should be replaced"|"1"|"COMMON"|"S"|"2000"|"15"|"0"|"refinish gym floor"|"1"|"INSTRUCT"|"S"|"2000"|"15"|"15000"|"refinish gym floor"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"15"|"0"|"northeast corner"|"CONCRETE,MASONRY,STEEL,WOOD,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2000"|"15"|"410000-1500000"|"repair masonry at loading dock, replace sealant and clean slate cladding/ replace cladding with new window wall"|"1"|"MASONRY,CONCRETE"|"S"|"1956"|"15"|"7500"|"concrete chimney caps are deteriorating and need metal caps"|"0"|"N/A"||||"0"||"S"|"S"|"0"|"1"|"2000"|"10"|"35000"|"replace loading dock doors and frames, replace classroom exterior doors and frames, add bollards at loading dock, add keyless entry to balance of exterior doors (except classrooms)"|"1"|"S"|"2000"|"15"|"20000"|"reconfigure ramp and stair at parking lot to comply with ADA"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"10"|"750000"|"replace all existing single glazed non thermally broken aluminum framed windows including the metal sun shades"|"METONMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"U"|"2000"|"5"|"2125000"|"continuing leaks:east side of gym over locker rooms; primary gym NE corner, fasteners backing out on second story single ply roof, majority of roof ponding water. Replacement of majority of roof membrane "|"1"|"OTHER"|"U"|"2000"|"5"|"0"|"majority of skylights cracked and crazed- Replacement of skylight. price included in roof amount above"|"1"|"GALVANIZED,COPPER"|"U"|"1956"|"0"|"75000"|"continual multiple leaks and significant buildup in existing galvanized cold water system-replace"|"1"|"IRON,COPPER"|"S"|"2001"|"10"|"0"||"1"|"NAT_GAS"|"U"|"1997"|"0"|"50000"|"hot water heater shloud be replaced"|"1"|"S"|"2010"|"20"|"0"||"1"|"CV,DD_MZ"|"1"|"BOILERSTEA,FURNACE"||"S"|"1957"|"5"|"0"|"and 1996"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"5"|"0"|"and 2000"|"1"|"S"|"1957"|"5"|"0"|"dual duct, cafeteria, gymnasium, shops all original"|"1"|"S"|"1957"|"10"|"0"|"and 1967"|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"5"|"75000"|"needs software upgrade"|"1"|"S"|"1996"|"5"|"100000"|"6 zones, not fully addressable"|"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1995"|"1995"|"20000"|"replace kitchen hood ansul system"|"1"|"S"|"1996"|"5"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"1"|"100000"|"some doors, hardware, toilet rooms and drnking fountains should be reconfigured to comply with ADA"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"1"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"1"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,LIGHTING"|"FULL"|"0"|"1"||"GOOD"|"serious shortage of storage for documents, records and custodial supplies"|"12,000,000"|"U"|"0"|"William Taylor Architects llc"|"6432 Baird Ave Syracuse NY 13206"|"315-432-0901"|"bill.taylor@taylor-architects.com"|"William F. Taylor"|"015542"|"I accept"|12/3/2010 2:05:40 PM| 117|"BOCES Madison-Oneida"|"25900000"|"Triplexus"|"8030"|"09/03/2010"|"4937 Spring RD "|"Verona"|"13478"|"ANNUAL"|"08/15/2011"|"1993"|"39000"|"2"|"1"|"0"|"LSD_DIST"|"INSTRUCT,OTHER,OTHER_ORG"|"meetings"|"165"|"5,6,7,8"|"0"|"1"|"0"|"165"|"0"|"0"|||"57"|"18000"|"ADMIN,ART,COMPROOM,GUIDANCE,MULTIPURPO,REMEDIAL,SCIENCELAB,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"SITESEPT"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"UTIL,SELF"|"ABOVE"|"S"|"2007"|"20"|"0"|"new cogen plant and some of the electrical was updated"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"|"2002"|"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"8"|"0"||"1"|"CONCRETE"|"S"|"2002"|"9"|"0"||"1"|"S"|"1996"|"2"|"0"||"1"|"S"|"2002"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"7"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"S"|"2002"|"10"|"0"||"1"|"S"|"1993"|"20"|"0"|"Stairs are to a second story mechanical space"|"0"|"S"|||"0"||"1"|"1"|"S"|"2006"|"20"|"0"|"Part of the cogen upgrade"|"1"|"S"|"2002"|"10"|"0"|"all lighting is t-8 277V"|"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"0"|"many small sized cracks @outside walls. Will require repair. Little evidence of wall penitration."|"1"|"METAL"|"S"|"1993"|"10"|"0"||"1"|"MASONRY,CONCRETE"|"S"|"1993"|"10"|"0"||"S"|"S"|"0"|"1"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1"|"2006"|"10"|"0"|"Cogen exit door. Jombi Ladder system"|"1"|"ALUMINUM"|"S"|"Y"|"2002"|"11"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"8"|"0"||"1"|"PLASTIC"|"S"|"1993"|"8"|"0"||"1"|"COPPER"|"S"|"2002"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2007"|"15"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"OTHER"|"1"|"BOILERWATE,OTHER"|"cogen"|"S"|"2007"|"15"|"0"|"New cogen"|"0"|"S"|||"0"||"1"|"S"|"2007"|"15"|"0"|"cogen system"|"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"|"A new cogen system has been istalled and upgraded the system."|"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"2007"|"2007"|"0"|"A sprinkler system was installed as part of the new Cogen project"|"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"|"1"|"GOOD"||"40000"|"S"|"1"|"William J. Murphy CO."|"303 E. Noyes BLVD"|"315-363-3682"|"murphy@twcny.rr.com"|"William J. Murphy"|"041799"|"I accept"|12/3/2010 2:29:06 PM| 118|"Penn Yan CSD"|"68060106"|"Penn Yan Elementary"|"0004"|"07/08/2010"|"3 School Drive"|"Penn Yan"|" 14527"|"ANNUAL"|"09/01/2010"|"1956"|"130000"|"2"|"8"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"693"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"1"|"693"|"0"|"0"|||"49"|"40225"|"ADMIN,ART,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"40"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"35"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"15"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"|"Ongoing inspection & maintenance."|"1"|"S"|"2005"|"20"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"20"|"0"|"Minor settlement cracks "|"1"|"S"|"2003"|"20"|"0"||"1"|"U"|"2003"|"5"|"70,000"|"Recommend replacing wall finishes @ all toilet rooms in classrooms."|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"|"N/A (cubbies in classrooms)"|"1"|"U"|"U"|"2003"|"5"|"50,000"|"Recommend replacing remaining original doors & door hardware."|"1"|"S"|"2003"|"20"|"0"||"1"|"U"|"2003"|"5"|"2,000"|"Recommend finish upgrades"|"1"|"1"|"S"|"2003"|"35"|"0"||"1"|"U"|"2003"|"5"|"44,000"|"Recommend replacing (36) 250W Metal Halide (Gym) w/ T5HO"|"1"|"1"|"S"|"2000"|"10"|"0"|"Network operating moved to ES. Existing Primex wireless clocks, IP Mitel Phones (PA - Good condition)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"2003"|"5"|"50,000"|"Recommend replacing VCT @ various areas (cracking/damaged)"|"1"|"COMMON"|"U"|"2003"|"5"|"2,000"|"Recommend replacing portion of floor in gym lobby (expansion/contraction issues)"|"1"|"INSTRUCT"|"S"|"2003"|"25"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"U"|"2003"|"5"|"50,000"|"Corridor tile (VCT) is cracking due to deflection in slab. Recommend adding supports"|"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"0"|"1"|"0"||"U"|"2003"|"5"|"25,000"|"Recommend repairing exterior soffit; seal louvers; correct thru-wall flashing @ gym"|"1"|"MASONRY"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"2003"|"5"|"5,000"|"Recommend replacing misc. exterior door & hardware"|"1"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"U"|"Y"|"2003"|"5"|"15,000"|"Recommend replacing slate stools (deteriorated) & caulking windows."|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"1"|"PLASTIC"|"E"|"2009"|"25"|"0"||"1"|"GALVANIZED,COPPER"|"U"|"2003"|"5"|"26,000"|"Recommend replacing original copper piping in '56 wing; insulation good condition"|"1"|"IRON,GALVANIZED,COPPER"|"U"|"2003"|"5"|"20,000"|"Recommend replacing threaded piping in 1956 area of the building."|"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"U"|"2003"|"5"|"105,000"|"Recommend replacing remaining '56 plumbing fixtures (flush valves leaking & poor condition)"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"40"|"0"||"1"|"S"|"2003"|"40"|"0"||"1"|"U"|"2003"|"5"|"53,000"|"Recommend replacing undersized RTU @ Main Office"|"1"|"S"|"2003"|"15"|"0"|"Suggest adding (future) relief to rooms 108/112/etc w/ fan coils"|"0"|"U"|"2003"|"5"|"9,000"|"Recommend district correct leaks @ crawlspace (below G117) - from UV's, etc"|"1"|"U"|"2003"|"5"|"2,000"|"Recommend replacing 20' of insulation by crawlspace stairs"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"|"FCI 7200 Point Addressable FACP"|"1"|"S"|"2003"|"15"|"0"|"Point Addressable devices"|"1"|"S"|"2003"|"2003"|"0"|"Ansul system on kitchen hood"|"1"|"S"|"2003"|"15"|"0"|"Fluorescent corridor lighting"|"1"|"S"|"2003"|"35"|"0"|"Ongoing inspection & maintenance."|"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"HVAC,COOKING,FIREALARM,FRIDGE,LIGHTING"|"WARMING"||"1"||"GOOD"||"528,000"|"U"|"1"|"King + King Architects LLP"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/3/2010 2:52:29 PM| 120|"Southern Cayuga CSD"|"05070104"|"Bus Garage"|"5004"|"08/20/2010"|"2384 Route 34B"|"Poplar Ridge"|" 13139"|"ANNUAL"|"10/01/2010"|"1969"|"7700"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"maintenance/storage/office"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"10000"|"S"|"1991"|"15"|"0"||"1"|"WELL"|"S"|"1969"|"10"|"0"|"1/2" line fed from H.S. in underground insulated duct."|"1"|"SITESEPT"|"S"|"1999"|"20"|"0"|"Pumped to H.S. septic field. (see H.S. notes)"|"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1990"|"10"|"0"|"30kVA pole mounted xfmrs feed to 200Amp ECB in parts room"|"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"10"|"0"|"Oil separator"|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"10"|"18,000"|"Recommend re-stripping and sealing cracks"|"1"|"ASPHALT"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1969"|"20"|"0"||"1"|"S"|"1969"|"15"|"0"|"District rep recommended insulating walls."|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2008"|"25"|"0"|"Ongoing maintenance & inspection of vehicle lifts"|"1"|"1"|"S"|"2003"|"15"|"0"|"Bus block heaters added 2000, (3) Square D panels w/ space available."|"1"|"S"|"2003"|"15"|"0"|"T8 fluorescent in bus areas & offices"|"1"|"1"|"E"|"2008"|"10"|"0"|"Cisco IP phone system; fiber LAN connected back to H.S."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2003"|"10"|"0"||"1"|"COMMON"|"S"|"1969"|"20"|"0"|"Minor cracks at slab (normal)"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1969"|"20"|"0"|"Minor settlement cracks (normal)"|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1969"|"20"|"0"|"minor dents/corrosion."|"1"|"METAL"|"S"|"2003"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"15"|"0"|"Safety sensors recently replaced on (2) OH Doors."|"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"2003"|"15"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"20"|"0"|"Upgraded w/ bus dispatch office renovation."|"1"|"IRON"|"S"|"2003"|"15"|"0"|"Upgraded w/ bus dispatch office renovation."|"1"|"ELECTRIC"|"S"|"2003"|"10"|"0"|"Upgraded w/ bus dispatch office renovation."|"1"|"S"|"2003"|"20"|"0"|"Upgraded w/ bus dispatch office renovation & has ADA toilets."|"0"||"1"|"BOILERWATE"||"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"fuel oil boiler"|"1"|"S"|"2003"|"10"|"0"|"Window A/C unit in Dispatch Office."|"1"|"S"|"2003"|"10"|"0"|"Original unit heaters in bus bays; new exhaust fans/UV installed 2003."|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"|"New zone-type panel installed."|"1"|"S"|"2003"|"15"|"0"|"New system."|"0"||||"0"||"1"|"S"|"2003"|"10"|"0"|"LED type exits."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"0"|"0"|"FAIR"||"18,000"|"S"|"1"|"King + King Architects LLP"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/3/2010 4:19:41 PM| 121|"Hauppauge UFSD"|"58050603"|"Bretton Woods Elementary"|"0007"|"6/30/10"|"1 Club Lane"|"Hauppauge "|" 11788"|"ANNUAL"|"5/1/10"|"1967"|"86,740"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"669"|"K,1,2,3,4,5"|"0"|"0"|"0"|"669"|"0"|"0"|||"35"|"28,165"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1994"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"|"PRZ on 4" main"|"1"|"SITESEPT"|"S"|"1967"|"20"|"0"||"1"|"S"|"1967"|"10"|"0"|"LP gas to burner pilots."|"1"|"UTIL"|"BELOW"|"E"|"2005"|"20"|"0"|"Separate meters on portables."|"1"|"S"|"1990"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"42,000"|"Flooding at lower exterior stairs - recommend visual inspection w/ camera within existing grate, install new 2" x 2" collection box"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"5"|"680,000"|"Portions of entry road leading to main rear parking lot are in need of reconstruction along with the main parking lot. Play areas, basketball courts, bus loop all in need of reconstruction."|"1"|"CONCRETE"|"S"|"2004"|"5"|"20,000"|"Replace a few cracked slabs."|"1"|"S"|"1990"|"10"|"0"|"Both playgrounds have safety surface, swing over sand."|"1"|"S"|"2000"|"10"|"0"|"N"|"Fields need top dressing & water (in house)."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"20"|"0"||"1"|"S"|"1967"|"10"|"0"||"1"|"S"|"1967"|"10"|"0"|"2 Areas within building where non-structural masonry step cracks occur - should be monitored. Stairwell to basement & several locations on stage - could be related to exterior masonry as outlined above."|"1"|"S"|"1990"|"10"|"90,000"|"Ceiling & grid replacement at the AP Room should be considered. "|"1"|"S"|"1967"|"6"|"0"|"No ADA lockers."|"1"|"S"|"S"|"2004"|"5"|"257,500"|"Change non-rated & incorrect swing doors. Install fire shutters above doors leading Cafeteria to Kitchen & Storage Room. Replace original doorknobs w/ high security classroom function lever. Long range plan to replace original doors."|"1"|"S"|"1967"|"10"|"0"|"Stairs to basement only."|"1"|"U"|"1967"|"10"|"0"|"Freight elevator only to basement."|"1"|"1"|"S"|"1967"|"10"|"0"|"208/120V 1600 amp service."|"1"|"S"|"2004"|"10"|"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"8"|"0"|"Principal & Asst Principal Offices, Library, Reading Room, Rooms 1-12, 1-13 & Counselor"|"1"|"INSTRUCT"|"S"|"2004"|"5"|"140,000"|"Replace remaining VAT - VAT is in good condition & monitored - long range plan for replacement should be considered "|"1"|"COMMON"|"S"|"1967"|"10"|"0"|"Bathrooms ceramic tile, terrazzo corridors."|"1"|"COMMON"|"S"|"1967"|"10"|"0"|"Stage & gym"|"SLABGRADE,OTHER"|"structural frame slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"10"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"S"|"2005"|"5"|"175,000"|"Repair minor cracks & repoint lintel ends. Repair thin brick at 1990 portable. Additional cracks along the AP Room should be addressed."|"1"|"MASONRY"|"S"|"1967"|"10"|"0"|"Metal flue extension on masonry chimney."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"10"|"29,000"|"A few original hollow metal doors, existing aluminum doors at Main Entrance & existing pair of doors in Custodial Office recommended to be replaced."|"1"|"S"|"1990"|"5"|"0"|"Replace railings removed on ramp by Room 2-5."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"10"|"120,000"|"Replace glass block windows in Gym & AP Room with mechanically operated top hinged window units."|"METONMET,OTHER"|"BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"0"||"S"|"2003"|"6"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"2004"|"10"|"0"||"1"|"OIL"|"S"|"1990"|"8"|"0"|"Hot water storage tank & 75 gallon oil fired hot water heater."|"1"|"S"|"2004"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1995"|"20"|"23,600"|"2 Weil McLain hot water boilers - boiler room ventilation upgrade. Increase ventilation & combustion air in boiler room."|"1"|"S"|"1995"|"20"|"0"|"2 Peabody Gordon Platt dual fuel burners."|"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"1967"|"5"|"0"|"Old unit ventilators & fan coil units to be changed Summer 2011."|"1"|"S"|"1967"|"6"|"0"||"1"|"S"|"1967"|"10"|"60,800"|"Air station filters & PRV's should be upgraded.Upgrade to new DDC panel for increased energy savings."|"1"|"S"|"2008"|"5"|"175,000"|"Recommend replacement"|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1967"|"1967"|"0"|"Ansul system & hoop."|"1"|"S"|"2004"|"6"|"0"||"1"|"NF"|"1967"|"0"|"120,000"|"System not working - recommend replacement"|"1"|"1"|"210,000"|"Provide accessible route to all facilities, fields; install railings on ADA ramp, handicapped accessible work spaces, sinks, drinking fountains, Nurse's office toilet."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Remove covering on a few fresh air intake grills."|"1"||"1"|"1"|"1"|"0"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2,122,900"|"U"|"0"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/3/2010 4:32:34 PM| 122|"Commack USFD"|"58041003"|"WOOD PARK PRIMARY SCHOOL"|"0014"|"03/31/2010"|"KINGS PARK ROAD "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1963"|"43000"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"425"|"K,1,2"|"0"|"1"|"0"|"425"|"0"|"0"|||"18"|"18072"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM"||"1"|"0"|"0"|"1"|"6000"|"S"|"1999"|"28"|"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"15"|"0"||"1"|"SITESEPT"|"S"|"1963"|"15"|"0"||"1"|"S"|"2010"|"10"|"0"|"Gas was installed."|"1"|"UTIL"|"BELOW"|"S"|"1963"|"3"|"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1963"|"5"|"0"||"1"|"CONCRETE"|"U"|"1963"|"1"|"100000"|"Sidewalks in front of building need replacement."|"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"1963"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1963"|"25"|"0"||"1"|"S"|"1963"|"25"|"0"||"1"|"S"|"1963"|"25"|"0"||"1"|"U"|"1988"|"1"|"100000"|"Most of the ceilings are not removable. Need to install suspended accesible ceilings or access panels to allow for inspection of the support roof structure above, which is the type susceptible to failure."|"0"||||"0"||"1"|"S"|"S"|"1963"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1963"|"5"|"0"||"1"|"S"|"2001"|"11"|"0"||"1"|"1"|"S"|"2001"|"11"|"0"||"0"||||"0"||"1"|"COMMON"|"E"|"2009"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"||"1"|"COMMON"|"S"|"1963"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"Expansion joints and caulking"|"U"|"1963"|"1"|"85000"|"Replace expansion joints and re-caulk unit ventilator grilles."|"1"|"MASONRY"|"E"|"2007"|"27"|"0"|"Chimney was replace after being damaged by lighting."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"0"||"1"|"S"|"1963"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"25"|"0"||"WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Not accessible for observation."|"S"|"2000"|"10"|"0"|"From above the roof it appears to be in normal conditions."|"0"|||||"0"||"1"|"COPPER"|"S"|"1963"|"5"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1963"|"5"|"0"||"0"|"NA"||||"0"|"Building has a hot water storage tank."|"1"|"S"|"1963"|"5"|"0"||"0"||"1"|"BOILERWATE"||"U"|"1963"|"1"|"400000"|"Replace existing boiler with two new boilers."|"1"|"S"|"1999"|"28"|"0"||"1"|"S"|"2000"|"39"|"0"||"1"|"U"|"1963"|"1"|"100000"|"Repair or replace exhaust fans and air handlers."|"1"|"U"|"1963"|"1"|"350000"|"Replace existing pumps and unit ventilators."|"1"|"S"|"1963"|"5"|"0"||"1"|"U"|"1998"|"1"|"50000"|"Provide DDC head end controller and perform full pneumatic rehab."|"1"|"U"|"2003"|"1"|"8000"|"New annunciator panels needed."|"1"|"S"|"2003"|"13"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"1963"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 1,200,000"|"U"|"1"|"Tagi A. Garbizu and Assoc."|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/3/2010 4:57:40 PM| 124|"Nyack UFSD"|"50030403"|"Hilltop Intermediate"|"0005"|"05/06/2010"|"13A DICKINSON AVENUE "|"NYACK "|" 10960"|"ANNUAL"|"03/01/2011"|"1954"|"53000"|"2"|"0"|"0"|"PART"|"DIST_ADMIN,OTHER,OTHER_ORG"|"Gym and theater"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|||"12"|"9500"|"ADMIN,AUDITORIUM,COMPROOM,GYM"||"1"|"0"|"0"|"2"|"8000"|"S"|"1989"|"10"|"0"|"1964 (8,000) gallon tank, tested yearly and passes. Second tank, 1,000 gallons."|"1"|"MUN_UTILIT"|"S"|"2006"|"25"|"$500.00"|"Repair pressure relief valve."|"1"|"MUN_UTILIT"|"S"|"1989"|"15"|"0"||"1"|"E"|"1964"|"15"|"$250.00"|"Three meters, re-paint rusted pipe."|"1"|"UTIL"|"BELOW"|"S"|"2000"|"2"|"$170,000.00"|"Replace CT, MDP and distribution panels."|"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"1"|"S"|"1950"|"0"|"$4,000.00"|"Collapsed dry well west side fitness, grate washout NW two story section."|"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1954"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1985"|"10"|"0"||"1"|"ASPHALT"|"S"|"1985"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"20"|"0"||"1"|"S"|"1964"|"20"|"0"||"1"|"S"|"2004"|"20"|"$10,000.00"|"Repair plaster in fitness loft."|"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"1964"|"1"|"$1,500.00"|"Second floor stairway handrails are missing and loose."|"0"||||"0"||"1"|"1"|"S"|"2005"|"20"|"$10,000.00"|"Boiler sub-panels have exceeded useful life."|"1"|"S"|"2005"|"20"|"0"||"1"|"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"2"|"$110,000.00"||"1"|"INSTRUCT,COMMON"|"S"|"1964"|"15"|"0"||"1"|"COMMON"|"S"|"1964"|"10"|"0"||"1"|"COMMON"|"S"|"1964"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"20"|"0"||"MASONRY"|"0"|"0"|"Corrosion on majority of exterior elements."|"0"|"0"|"0"|"0"|"0"||"S"|"1964"|"15"|"$20,000.00"|"Scrape and paint exterior elements."|"1"|"METAL"|"S"|"1964"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1964"|"15"|"$10,000.00"|"Exit door - north end east hallway and NE corner of building interconnection need to be replaced, weatherstrip doors, fitness center doors."|"1"|"S"|"1964"|"0"|"$8,000.00"|"Rebuild and add 2nd rail at steps to paved area."|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"2005"|"2"|"$350,000.00"|"Replace at portables and 1964 section."|"METONMET,OTHER"|"SINGLEPLY,BUILTUP,ASPHALT,FORMMETAL"|"0"|"0"|"0"|"0"|"0"|"Cracks in metal panels. Reinforce or replace."|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"|"Vegitation and moss on roof section. Rotted TECTUM Plank in gym. SW corner must be replaced."|"S"|"2000"|"5"|"$360,000.00"|"EPDM roof on college section (22,000 sf) nearing end of service life. Consider replacement."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2006"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1964"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"1964"|"5"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"Unit ventilation"|"E"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2010"|"0"|"0"|"Replacement is ongoing. All through wall units are 2 to 5 years old."|"1"|"S"|"1954"|"5"|"0"||"1"|"S"|"2009"|"5"|"0"||"1"|"S"|"1954"|"10"|"0"||"1"|"S"|"2005"|"25"|"0"|"1964 wing needs replacement."|"1"|"S"|"1990"|"10"|"0"|"Partial upgrade. New pull stations installed in 2009."|"1"|"S"|"1990"|"10"|"0"|"Heat detectors were added in 2009."|"0"||||"0"||"1"|"S"|"2010"|"15"|"0"|"Reapirs are on going."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"1"|"4000"|"Second floor classrooms in 1954 wing have reent leaks from roof HVAC."|"1"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$1,058,250.00"|"S"|"0"|"DCAK-MSA Architecture"|"53 Hudson Ave. Nyack, NY 10960"|"845-353-1300"|"dc@dcak-msa.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/5/2010 7:29:57 PM| 125|"Nyack UFSD"|"50030403"|"Old High School"|"0003"|"05/26/2010"|"131 NORTH MIDLAND AVENUE "|"NYACK "|" 10960"|"ANNUAL"|"03/01/2011"|"1928"|"116,200"|"3"|"6"|"11"|"LSD_NDE"|"INSTRUCT"||"630"|"6,7,8,9,10,11,12"|"0"|"1"|"0"|"630"|"0"|"0"|||"49"|"30,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,MULTIPURPO,MUSIC,SCIENCELAB,SPECED"||"1"|"0"|"0"|"1"|"8,000"|"S"|"1986"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1929"|"10"|"$5,000.00"|"4" service, replace gate valves."|"1"|"MUN_UTILIT"|"S"|"1949"|"10"|"$100.00"|"Replace broken clean-out cap."|"1"|"S"|"2005"|"20"|"$800.00"|"Scrape and paint rusted pipe."|"1"|"UTIL"|"BELOW"|"E"|"2009"|"20"|"0"||"1"|"S"|"2007"|"20"|"0"||"0"||||"0"||"1"|"S"|"1928"|"15"|"0"||"0"||||"0"||"1"|"MUNI,SURFACEH2O"||"1"|"S"|"1928"|"20"|"0"||"0"||||"0"||"1"|"E"|"2007"|"30"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1995"|"5"|"$60,000.00"|"Pot holes and cracks need repair. Repair north drive retailing wall."|"1"|"CONCRETE,ASPHALT"|"S"|"2007"|"5"|"$30,000.00"|"Deteriorating stairways/railing need to be replaced at several locations."|"0"||||"0"||"1"|"S"|"1949"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"1"|"1"|"0"|"0"|"S"|"1949"|"20"|"$35,000.00"|"Repair deteriorated foundation on 1949 wing."|"1"|"S"|"1949"|"20"|"0"||"1"|"S"|"1949"|"20"|"$4,000.00"|"Repair holes, cracks, mortar in all spaces."|"1"|"S"|"1949"|"10"|"$3,000.00"|"Replace misc. damaged tiles. Consider replacement of metal panel ceilings."|"1"|"S"|"1949"|"15"|"0"|"Lockers being repainted at time of inspection."|"1"|"S"|"S"|"1949"|"5"|"$14,000.00"|"Replace many lock sets and non-ADA compliant closers. Non-rated door at boiler room scheduled for replacement."|"1"|"S"|"1949"|"20"|"$5.000.00"|"Stair with bottom tread missing. Rails need replacement and repair."|"1"|"S"|"1949"|"10"|"0"||"1"|"1"|"S"|"2009"|"5"|"$250,000.00"|"Replace antiquated switch gear and distribution pnels."|"1"|"S"|"1949"|"10"|"0"|"Original fixtures an 1949 addition. Consider replacement."|"1"|"1"|"S"|"2009"|"15"|"0"|"Updated phone system serves as P.A."|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"5"|"$3,300.00"|"Replace office #4 carpet. No fire certificate for aduitorium carpet, replace 4 other areas."|"1"|"INSTRUCT,COMMON"|"S"|"1949"|"5"|"0"|"Worn but clean and serviceable."|"1"|"COMMON"|"S"|"1949"|"15"|"$800.00"|"Replace missing floor tiles, second floor boys and girls rooms."|"1"|"COMMON"|"S"|"1929"|"10"|"0"|"Gym and stage."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1949"|"20"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"S"|"1949"|"20"|"$320,000.00"|"Replace window lintels and rotting eaves (1928 building), pre-cast sills (1949 addition). Plaster soffit cracks."|"1"|"MASONRY"|"S"|"1949"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"25"|"0"||"1"|"S"|"1949"|"15"|"$40,000.00"|"Repair railings and boiler room stair deck and areaway retaining wall."|"0"|||||"0"||"1"|"ALUMINUM,STEEL,OTHER"|"S"|"Y"|"1994"|"10"|"0"|"Deteriorated glass block window walls at 1949 addition scheduled for replacement."|"METONMET,WOODONMET,OTHER"|"SINGLEPLY,BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Air pockets under membrane roofing."|"S"|"1990"|"10"|"$500.00"|"Repair small leaks over 1949 wing SE vestibule."|"0"|||||"0"||"1"|"COPPER"|"S"|"1949"|"10"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"1949"|"10"|"0"||"1"|"OIL,NAT_GAS"|"S"|"2005"|"25"|"0"||"1"|"S"|"1949"|"10"|"$3,000.00"|"Replace two toilets, replace 1 sink, add ADA waste pipe wraps to 4 sinks."|"0"||"1"|"BOILERWATE"||"E"|"2005"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1949"|"10"|"0"|"Wall/window units, ductless split for lower level classrooms."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"$1,000.00"|"Pump flanges leak."|"0"|"S"|"1949"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"|"No tie to District Energy Management system."|"1"|"S"|"1949"|"5"|"$150,000.00"|"No strobes. Recommend replacement with Addressable System."|"1"|"S"|"1949"|"5"|"0"|"Cost included in Fire Alarm System cost above."|"0"||||"0"||"1"|"S"|"1949"|"5"|"$45,000.00"|"Gym exit light above locked door. Recommend replacing antiquated system."|"1"|"S"|"1949"|"5"|"$160,000.00"|"Enclosure rusted. Recommend replacement of ATS and generator."|"1"|"1"|||"FAIR"||"FAIR"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"1"|"2400"|"Replacement of damaged and stained ACT."|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"$1,132,900.00"|"S"|"1"|"DCAK-MSA Architecture"|"53 Hudson Ave. Nyack, NY 10960"|"845-353-1300"|"dc@dcak-msa.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/5/2010 8:35:17 PM| 128|"Hammondsport CSD"|"57290104"|"Bus Garage"|"5003"|"07/29/2010"|"MAIN ST "|"HAMMONDSPORT "|" 14840"|"ANNUAL"|"05/05/2011"|"2007"|"16150"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"bus maintenance and storage"|"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||"2007"||"0"||"1"|"MUN_UTILIT"|"E"|"2007"|"25"|"0"||"1"|"SITESEPT"|"S"|"2007"|"25"|"0"||"1"|"S"|"2007"|"25"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"OTHER"|"cold brook creek"|"0"|"E"|"2007"|"25"|"0"||"0"||||"0"||"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2007"|"15"|"0"||"1"|"CONCRETE"|"E"|"2007"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"|"meatl stairs to access mezzanine storage"|"0"||||"0"||"1"|"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2007"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2007"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"25"|"0"||"1"|"METAL"|"E"|"2007"|"25"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2007"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"0"|"ALUMINUM"|"E"|"NA"|"2007"|"25"|"0"||"OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2007"|"25"|"0"||"1"|"IRON,COPPER"|"E"|"2007"|"25"|"0"||"1"|"NAT_GAS"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"CV,VAV"|"1"|"FURNACE,OTHER"|"radiant"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"0"|"E"|"2007"|"25"|"0"||"0"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|||"1"||"GOOD"||"0"|"E"|"0"|"William Taylor Architects "|"6432 Baird Ave Syracuse ny 13206"|"315-432-0901"|"bill.taylor@taylor-architects.com"|"William F. Taylor"|"015542"|"I accept"|12/6/2010 9:48:25 AM| 129|"BOCES Broome-Tioga"|"03900000"|"Central Business Office 1"|"1030"|"09/03/2010"|"100 Marshall Drive"|"Endicott"|" 13760"|"ANNUAL"|"12/01/2010"|"1992"|"8015"|"1"|"0"|"0"|"LSD_DIST"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"3000"|"back flow preventer"|"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2004"|"25"|"0"||"0"||||"0"||"1"|"S"|"1992"|"20"|"21000"|"provide gutters and downspouts"|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1992"|"10"|"0"||"1"|"CONCRETE"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"10"|"0"|"consists of t12 lamps and ballasts"|"1"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1992"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"15"|"0"||"1"|"METAL"|"S"|"1992"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1992"|"10"|"0"||"METONMET"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2004"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"5"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"65000"|"provide emergency generator"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"1"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"89000"|"S"|"1"|"Clark Patterson Lee"|"59 Court Street Binghamton, N.Y. 13901"|"1-800-274-9000"|"rwarholic@clarkpatterson.com"|"John J. Martin, PE"|"057961"|"I ACCEPT"|12/6/2010 11:54:37 AM| 130|"Canajoharie CSD"|"27030104"|"High School"|"0014"|"08/18/2010"|"136 Scholastic Way"|"Canajohaire"|" 13317"|"ANNUAL"|"01/11/2011"|"2001"|"168245"|"2"|"7"|"2"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"349"|"9,10,11,12"|"0"|"0"|"1"|"349"|"0"|"0"|||"32"|"33111"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2001"|"30"|"0"||"1"|"MUN_UTILIT"|"E"|"2001"|"30"|"0"||"1"|"E"|"2001"|"30"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2001"|"30"|"0"||"1"|"E"|"2001"|"30"|"0"||"1"|"E"|"2001"|"15"|"0"||"1"|"E"|"2001"|"30"|"0"||"1"|"E"|"2001"|"30"|"0"||"1"|"ONSITE"||"1"|"E"|"2001"|"20"|"0"||"0"||||"0"||"1"|"E"|"2001"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"15"|"30000"|"Sealcoating needed within 5 years"|"1"|"CONCRETE"|"E"|"2001"|"25"|"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"|"N"|"Athletic track sealcoated in 2008"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2001"|"50"|"0"||"0"||||"0"||"1"|"E"|"2001"|"50"|"0"||"1"|"E"|"2001"|"15"|"0"||"1"|"E"|"2001"|"15"|"0"||"1"|"S"|"S"|"2001"|"5"|"150000"|"Misc. exit device hardware requires adjustment or replacement"|"1"|"E"|"2001"|"30"|"0"||"1"|"E"|"2001"|"30"|"0"||"1"|"1"|"E"|"2001"|"30"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"1"|"E"|"2001"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"20000"|"Carpet in Auditorium needs replacment soon."|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"E"|"2008"|"25"|"0"|"Misc. repair work done in Main Lobby area"|"1"|"COMMON"|"E"|"2001"|"25"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2001"|"50"|"0"||"CONCRETE,STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2001"|"30"|"0"||"1"|"METAL"|"E"|"2001"|"30"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2008"|"25"|"0"|"Main Entry Exterior vestibule reconfigured for security purposes in 2008"|"1"|"S"|"2001"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2001"|"25"|"0"||"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"|"Leak at roof edge, problem identified - repair in progress"|"1"|"PLASTIC"|"E"|"2001"|"15"|"0"||"1"|"COPPER"|"E"|"2001"|"30"|"0"||"1"|"IRON"|"E"|"2001"|"30"|"0"||"1"|"NAT_GAS"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"25"|"0"||"1"|"VAV"|"1"|"BOILERWATE"||"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"30"|"0"|"Upgrade EMS computer software, provide web based system"|"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"2001"|"0"|"ansul system at kitchen hood and sprinkler system/hose cabinets at auditorium stage"|"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2008"|"40"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,LIGHTING"|"FULL"||"1"||"GOOD"||"220000"|"E"|"0"|"Glynn Spillane Griffing Architects PC"|"187 Wolf Road Suite 211"|"518 463 1114"|"rmichel@gsgarchitects.com"|"Richard Michel"|"022253"|"I accept"|12/6/2010 12:41:52 PM| 131|"Penn Yan CSD"|"68060106"|"Bus Garage / District Office"|"5019"|"7/8/10"|"1 SCHOOL DR "|"PENN YAN "|" 14527"|"ANNUAL"|"9/1/10"|"1954"|"6600"|"2"|"0"|"1"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Transportation/Storage"|"0"||"0"|"0"|"0"||||||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"8000"|"S"|"2005"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"20"|"0"|"Fed from PYE"|"1"|"MUN_UTILIT"|"S"|"1954"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"|"Distribution manifold piping modified for new RTU"|"1"|"UTIL"|"ABOVE"|"S"|"1973"|"25"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"1954"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2003"|"40"|"0"||"1"|"SURFACEH2O"||"0"|"S"|"2003"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"20"|"0"||"1"|"ASPHALT"|"S"|"2005"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1975"|"20"|"0"||"1"|"S"|"1954"|"20"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"15"|"0"||"1"|"S"|"1973"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"1"|"S"|"2006"|"10"|"0"|"Cisco PoE switches, fiber connection to district-wide LAN"|"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"1954"|"30"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1954"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"U"|"1975"|"5"|"5000"|"Recommend repairing minor step cracks @ overhead door"|"1"|"METAL"|"S"|"2003"|"15"|"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1990"|"5"|"45000"|"Recommend replacing (6) overhead doors & (3) frames (corroded)"|"1"|"S"|"1990"|"15"|"0"||"1"|"U"|"1"|"1973"|"5"|"50000"|"Recommend upgrading railings & reinforcing structure as req'd"|"1"|"ALUMINUM,STEEL"|"U"|"NA"|"1990"|"5"|"30000"|"Recommend replacing existing windows "|"METONMET,WOODONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1994"|"20"|"0"||"1"|"GALVANIZED"|"S"|"1990"|"20"|"0"|"Office area toilet rooms added"|"1"|"NAT_GAS,ELECTRIC"|"U"|"1995"|"5"|"3000"|"Electric WH for utility sink beyond useful life; gas WH approaching life expectancy"|"1"|"S"|"1990"|"20"|"0"|"Office area toilet rooms added '90"|"1"|"VAV"|"0"|"FURNACE"||"S"|"2006"|"15"|"0"|"Packaged NG/DX RTU"|"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"|"Packaged NG/DX RTU"|"1"|"S"|"2006"|"10"|"18000"|"Recommend adding exhaust, no exhaust in bus bay"|"1"|"S"|"1954"|"5"|"35000"|"Recommend replacing (4) original gas unit heaters in bus/maintenance area (leaking flues)"|"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"10"|"0"|"2-zone Fire-Lite fire alarm control pane"|"1"|"S"|"2006"|"10"|"0"|"Duct smoke & FSD added to 2-zone Fire-Lite Panel"|"0"||||"0"||"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"0"|"1"|"FAIR"||"186000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/6/2010 1:36:34 PM| 133|"Commack USFD"|"58041003"|"LONG ACRES ELEMENTARY SCHOOL"|"0012"|"02/19/2010"|"BETTE LANE "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1962"|"53000"|"1"|"2"|"1"|"LSD_NDE"|"INSTRUCT,OTHER"||"102"|"5,6,7,8,9"|"0"|"0"|"0"|"102"|"0"|"0"|||"23"|"21000"|"ADMIN,ART,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,LGGROUP,MULTIPURPO,SPECED,TECHSHOP"|"Cafeteria is in Multi Purpose Rm."|"1"|"0"|"0"|"1"|"10000"|"E"|"2009"|"30"|"0"||"1"|"MUN_UTILIT"|"U"|"2000"|"1"|"2500"|"Replace main valve"|"1"|"SITESEPT"|"S"|"1962"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"44"|"0"||"1"|"S"|"1962"|"15"|"0"||"0"||||"0"||"1"|"S"|"1962"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"5"|"0"||"0"||||"0"||"1"|"S"|"1962"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"25"|"0"||"1"|"S"|"1962"|"25"|"0"||"1"|"S"|"1962"|"25"|"0"||"1"|"U"|"1962"|"1"|"50000"|"Replace original ceilings with 2'x4' suspended system."|"0"||||"0"||"1"|"U"|"U"|"1962"|"1962"|"300000"|"Replace interior doors as needed."|"1"|"S"|"1962"|"15"|"0"|"Interior stair to Boiler Room only."|"0"||||"0"||"1"|"1"|"S"|"2004"|"5"|"0"||"1"|"U"|"1962"|"1"|"100000"|"Replace otiginal fixtures as required."|"1"|"1"|"S"|"2004"|"19"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"U"|"1988"|"1"|"100000"|"Replace carpet as required."|"1"|"INSTRUCT,COMMON"|"U"|"1988"|"1"|"100000"|"Replace vinyl tile flooring as required."|"1"|"COMMON"|"S"|"1962"|"5"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Cast-in-place over crawlspaces."|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"Need caulking around UV louvers"|"S"|"1962"|"5"|"0"||"1"|"MASONRY"|"U"|"1962"|"1"|"60000"|"Needs repointing and flashing replacement."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1962"|"1"|"150000"|"Replace original doors as required."|"1"|"S"|"1962"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1962"|"1"|"380000"|"Replace windows as required."|"WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"5"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1962"|"1"|"10000"|"Install isolation valves."|"1"|"IRON,GALVANIZED"|"S"|"1962"|"5"|"0"||"0"|||||"0"||"1"|"S"|"1962"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1998"|"27"|"0"||"1"|"S"|"1998"|"27"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"1962"|"5"|"0"||"1"|"S"|"1962"|"5"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"U"|"1962"|"1"|"75000"|"Provide DDC head end controller and perform full pneumatic rehab."|"1"|"S"|"1962"|"1"|"65000"|"Upgrade system to comply with ADA requirements and as needed."|"1"|"U"|"1962"|"1"|"10000"|"Install additional detector heads in areas of assembly."|"0"||||"0"||"1"|"U"|"1962"|"1"|"8000"|"Repair or replace old system."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"|"0"|"1"|"0"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 1,420,500"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012745"|"I accept"|12/6/2010 2:31:50 PM| 134|"BOCES Broome-Tioga"|"03900000"|"Central Business Office 2 (Admin)"|"1043"|"09/03/2010"|"100 Marshall Drive"|"Endicott"|" 13760"|"ANNUAL"|"12/01/2010"|"1992"|"8015"|"1"|"0"|"0"|"LSD_DIST"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"3000"|"back flow preventer"|"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2004"|"25"|"0"||"0"||||"0"||"1"|"S"|"1992"|"20"|"21000"|"provide gutters and downspouts"|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1992"|"10"|"0"||"1"|"CONCRETE"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1992"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"15"|"0"||"1"|"METAL"|"S"|"1992"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1992"|"10"|"0"||"METONMET"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2004"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"5"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"15000"|"no existing system"|"0"||||"10000"|"no existing system"|"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"65000"|"provide emergency generator"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"1"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"114000"|"S"|"1"|"Clark Patterson Lee"|"59 Court Street Binghamton, N.Y. 13901"|"1-800-274-9000"|"rwarholic@clarkpatterson.com"|"John J. Martin, PE"|"057961"|"I ACCEPT"|12/6/2010 3:49:15 PM| 135|"Hauppauge UFSD"|"58050603"|"Forest Brook Elementary"|"0010"|"9/14/10"|"Lilac Lane"|"Smithtown"|" 11787"|"ANNUAL"|"5/1/11"|"1956"|"59,840"|"2"|"4"|"1"|"DISTRICT"|"INSTRUCT"||"474"|"K,1,2,3,4,5"|"0"|"1"|"1"|"474"|"0"|"0"|||"25"|"19,660"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"15,000"|"E"|"2003"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"SITESEPT"|"E"|"2008"|"25"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1998"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"465,000"|"Main parking lot, service road adj to kitchen, play area & court, outside gym, bus loop & front parking lot reconstruction"|"1"|"CONCRETE"|"S"|"2004"|"10"|"0"||"1"|"S"|"1990"|"7"|"0"||"1"|"S"|"1990"|"6"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"25"|"0"||"1"|"S"|"1956"|"25"|"0"||"1"|"S"|"1956"|"25"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"1956"|"10"|"0"||"1"|"S"|"S"|"2000"|"12"|"104,000"|"Replace original doorknobs w/ classroom function lever. Install magnetic hold opens on doors to places of assembly."|"1"|"S"|"1956"|"15"|"0"||"1"|"S"|"1956"|"10"|"0"|"Dumbwaiter"|"1"|"1"|"S"|"1956"|"10"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"6"|"0"|"Carpet exists in Guidance & Room 504."|"1"|"INSTRUCT,COMMON"|"S"|"2008"|"12"|"268,800"|"Recommend replacement of remaining VAT flooring. Also recommend replacement of VCT flooring throughout corridors."|"1"|"COMMON"|"S"|"1956"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"12"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"25"|"103,000"|"Due to freeze/thaw cycle brick at upper gym wall has expanded & facebricks dislodged. Recommend powerwash to remove paint. Repoint mortar joints. Replace ext louvers at gym"|"1"|"MASONRY"|"E"|"2007"|"25"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2004"|"10"|"33,000"|"Replace cafeteria vestibule doors & windows along exterior wall and ext door & frame to boiler room"|"1"|"S"|"1956"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2004"|"20"|"152,000"|"Recommend replacement of girls' block windows"|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"5"|"0"|"Warranty expires in 2004"|"1"|"PLASTIC"|"S"|"1994"|"5"|"0"||"0"|"IRON,COPPER"|"S"|"2004"|"15"|"0"||"1"|"IRON"|"S"|"2004"|"15"|"0"||"1"|"OIL"|"S"|"2006"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1994"|"30"|"0"||"1"|"S"|"1994"|"30"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1994"|"10"|"68,000"|"Boiler room ventilation upgrade - repair fireside leakage, remove existing barometric dampers & install new dampers in boiler vent."|"1"|"S"|"1956"|"4"|"920,000"|"Replace 1 rooftop unit over main office - remove 32 Nesbit hot water unit ventilators & install new unit ventilators - install new bookcased mfg by unit ventilator manufacturer"|"1"|"S"|"1956"|"10"|"0"||"1"|"S"|"1956"|"5"|"211,000"|"Upgrade to new DDC panel. Due to combined condition of equipment & controls, recommend replacement. Work should include rehabilitation of building exhaust fans"|"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"1956"|"1956"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"0"|"0"|"463,000"|"Toilets to be accessed directly from corridor, Health Office handicapped accessible toilet - install automatic door actuators, accessible work spaces/sinks"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"1"|"1"||"GOOD"||"2,304,800"|"E"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/6/2010 4:50:32 PM| 136|"BOCES Eastern Suffolk"|"58910000"|"NY Institute Adult Center"|"8086"|"11/12/2010"|"PO Box 9029"|"Central Islip"|" 11722"|"ANNUAL"|"05/01/2011"|"1930"|"39384"|"3"|"5"|"0"|"LSD_DIST"|"OTHER"|"Adult Education"|"0"|||"0"|"0"||||||"0"|"0"|"ADMIN,OTHER"|"Adult Education"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1930"|"10"|"0"||"1"|"S"|"1960"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"6"|"0"||"1"|"S"|"1960"|"10"|"0"||"0"||||"0"||"1"|"U"|"1960"|"1"|"0"|"New drainage needed in unpaved parking areas."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2004"|"1"|"40,000"|"Pavement needed in unpaved parking area on west side."|"1"|"CONCRETE,ASPHALT"|"S"|"1999"|"4"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"1"|"1"|"0"|"0"|"S"|"1950"|"20"|"0"||"1"|"S"|"1930"|"10"|"0"|"Monitor cracks in stairwell walls by Rm. 201."|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1930"|"6"|"0"||"0"||||"0"||"1"|"U"|"U"|"2009"|"1"|"8,500"|"Some doors in bathrooms shall be replaced."|"1"|"S"|"1930"|"15"|"0"||"0"|"U"|"1930"|"1"|"103,000"|"Elevator is needed in a 3-story bldg."|"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"1"|"S"|"2001"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1990"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1990"|"10"|"0"||"1"|"COMMON"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Cast in place concrete slabs"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1930"|"15"|"0"||"MASONRY"|"1"|"0"|"Some steel lintels are rusting"|"1"|"0"|"0"|"1"|"1"||"U"|"2000"|"1"|"38,000"|"Repair and repoint brick where needed."|"1"|"MASONRY"|"S"|"1973"|"11"|"0"||"1"|"MASONRY"|"S"|"1930"|"15"|"0"||"S"|"S"|"0"|"1"|"2009"|"6"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOOD"|"S"|"NA"|"1990"|"10"|"0"||"WOODONMET"|"BUILTUP,SLATE"|"1"|"0"|"1"|"0"|"0"||"0"|"1"|"1"|"1"|"0"|"0"|"0"|"0"||"S"|"2009"|"10"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1990"|"10"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1990"|"11"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"9"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2009"|"9"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"|"S"|"1990"|"4"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"2009"|"9"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"U"|"2000"|"1"|"5,000"|"Upgrade to comply with ADA requirements."|"1"|"U"|"2006"|"1"|"2,000"|"Upgrade with Fire Alarm System."|"1"|"U"|"2006"|"2006"|"2,000"|"Install flow switches in floors 1, 2 and 3."|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"0"|"103,000"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Portico"|"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"198,500"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/6/2010 5:56:36 PM| 137|"Union Springs CSD"|"05190104"|"AJ Smith Elementary"|"0006"|"7/13/10"|"26 Homer Street"|"Union Springs"|" 13160"|"ANNUAL"|"10/01/10"|"1966"|"42500"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"197"|"4,5,6"|"0"|"0"|"1"|"197"|"0"|"0"|||"15"|"11884"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"10"|"0"||"1"|"S"|"1966"|"10"|"0"|"Gas well."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"10"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"U"|"1997"|"5"|"26000"|"Drainage ditch that discharges at Evergreen Street overflows onto adjacent property."|"1"|"S"|"1997"|"20"|"0"|"Suggest District clean structure of debris."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"10"|"10000"|"Recommend re-striping and sealing asphalt."|"1"|"CONCRETE,ASPHALT"|"S"|"1997"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"|"Wood fiber mulch replaced in 2009. Inspected annually by BOCES"|"1"|"S"|"1997"|"5"|"18000"|"N"|"Recommend color seal basketball court; shallow depth of bedrock "|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1966"|"15"|"0"|"Extremely clean crawl space."|"1"|"S"|"1966"|"15"|"0"||"1"|"S"|"1966"|"15"|"0"||"1"|"S"|"2009"|"5"|"5000"|"Recommend replacing ceiling systems @ Cafetorium & 6th grade toilet rms."|"1"|"S"|"1978"|"5"|"0"|"Lockers (6th grade wing) original but functional."|"1"|"S"|"S"|"2009"|"20"|"0"|"Door hardware upgraded w/ EXCEL funds."|"1"|"S"|"1966"|"20"|"0"||"1"|"E"|"2010"|"30"|"0"|"Cylinders replaced."|"1"|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"2009"|"25"|"0"||"0"|"1"|"S"|"2009"|"5"|"70000"|"Recommend replacing Simplex 120v sync clock system w/ wireless (Owner request)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"10"|"0"|"New carpet @ Library & Main Office"|"1"|"INSTRUCT,COMMON"|"S"|"1998"|"10"|"0"||"1"|"COMMON"|"S"|"1966"|"30"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1966"|"5"|"14000"|"Recommend refinishing cafetorium (stage) floors"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1966"|"15"|"0"||"MASONRY"|"0"|"0"|"Uninsulated - District requests improved insulation/energy savings"|"1"|"0"|"0"|"0"|"1"|"Spalled conc."|"U"|"1966"|"5"|"285000"|"Recommend scraping/parging/painting walls; Install EIFS system"|"1"|"CONCRETE"|"S"|"1966"|"5"|"2000"|"Recommend scraping/painting cmu."|"1"|"MASONRY"|"S"|"2002"|"15"|"0"||"U"|"S"|"0"|"1"|"1966"|"5"|"50000"|"Recommend replacing misc. doors & door hardware"|"1"|"S"|"1997"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"0"||"1"|"PLASTIC"|"U"|"1997"|"5"|"5,000"|"Recommend replacing skylights @ gym. MS Gym skylights leak"|"1"|"GALVANIZED,COPPER"|"U"|"1998"|"5"|"18,000"|"Recommend adding booster pump to increase water pressure."|"1"|"IRON,COPPER"|"S"|"1998"|"10"|"0"||"1"|"NAT_GAS"|"U"|"2005"|"5"|"61,000"|"Recommend replacing unit w/ high efficiency unit (natural gas)."|"1"|"U"|"1998"|"5"|"236,000"|"Recommend replacing fixtures @ (9) classrooms."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1998"|"5"|"96,000"|"Recommend adding A/C to library, main office, and data closets"|"1"|"U"|"1998"|"5"|"140,000"|"Recommend replacing original equip (no ventilation @ Guidance/Nurse/etc)"|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1966"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"|"DDC system exists (Johnson Controls)"|"1"|"U"|"1998"|"5"|"166,000"|"Recommend replacing Simplex 2005 8-zone FACP w/ addressable system; add clrm strobes"|"1"|"S"|"1998"|"5"|"53,000"|"Recommend adding point addressable device w/ new FACP"|"1"|"U"|"1966"|"1966"|"10,000"|"Recommend adding ansul panel @ electric range"|"1"|"U"|"1998"|"5"|"10,000"|"Recommend adding misc battery emergency lighting"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"|"0"|"FAIR"|"District will be discussing consolidation of elementary facilities."|"1,275.000"|"U"|"1"|"King + King Architects"|"358 West Jefferson St., Syracuse NY 13202"|"315 682 6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I accept"|12/7/2010 11:17:40 AM| 138|"BOCES Eastern Suffolk"|"58910000"|"NY Institute Kennedy Center"|"8090"|"11/12/2010"|"PO Box 9029"|"Central Islip"|" 11722"|"ANNUAL"|"05/01/2011"|"1930"|"39384"|"3"|"5"|"0"|"LSD_DIST"|"OTHER"|"Nursing School"|"0"|||"0"|"0"||||||"0"|"0"|"ADMIN,OTHER"|"Nursing School"|"1"|"2"|"660"|"0"|"0"|"S"|"1994"|"9"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"5"|"0"|"Water Main Service in basement is in poor condition."|"1"|"MUN_UTILIT"|"S"|"1950"|"10"|"0"||"1"|"S"|"1960"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"5"|"0"||"1"|"S"|"1960"|"10"|"0"||"0"||||"0"||"1"|"U"|"1960"|"1"|"10,000"|"Additional drainage pools are needed at South Entrance."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2004"|"2"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1999"|"3"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1930"|"20"|"0"||"1"|"S"|"1930"|"10"|"0"|"Monitor cracks in west side staircase."|"1"|"S"|"1998"|"11"|"0"||"1"|"S"|"1930"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"5"|"0"||"1"|"S"|"1930"|"15"|"0"||"1"|"U"|"1930"|"1"|"103,000"|"Elevator is needed for a 3-story bldg."|"1"|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1998"|"5"|"0"||"1"|"1"|"S"|"2004"|"5"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1990"|"5"|"0"||"1"|"COMMON"|"S"|"1990"|"5"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Cast in place reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1930"|"15"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"0"|"1"|"0"||"U"|"1960"|"1"|"16,800"|"Repair and repoint brick at west corner of South Entrance."|"1"|"METAL"|"S"|"1960"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"5"|"0"||"1"|"S"|"2007"|"2"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOOD"|"S"|"Y"|"1990"|"5"|"0"||"WOODONWOOD"|"BUILTUP,SLATE"|"1"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"U"|"2009"|"2"|"8,500"|"Repair gutters and leaders at west corner of South Entrance."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1990"|"5"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1990"|"5"|"0"||"0"|"NAT_GAS"|"S"|"1985"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2010"|"15"|"0"||"1"|"S"|"1996"|"5"|"0"||"0"||||"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1996"|"5"|"0"||"0"||||"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"U"|"1990"|"1"|"4,200"|"Upgrade systems to comply with ADA regulations."|"1"|"S"|"1990"|"5"|"10,300"|"Upgrade systems to comply with ADA regulations."|"0"||||"0"||"1"|"S"|"2005"|"5"|"0"||"0"||||"0"||"1"|"0"|"103,000"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Under terrace"|"0"|||"1"|"0"|"10,000"||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"162,800"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/7/2010 11:37:43 AM| 139|"BOCES Broome-Tioga"|"03900000"|"Maintenance Building"|"3007"|"09/03/2010"|"435 Glenwood Road"|"Binghamton"|" 13905"|"ANNUAL"|"12/01/2010"|"1974"|"5714"|"1"|"2"|"2"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"|"1 1/2" rp2"|"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"S"|"1974"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1974"|"1"|"50000"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1974"|"15"|"0"||"1"|"U"|"1974"|"1"|"25000"|"fire seperation"|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1974"|"10"|"0"||"1"|"S"|"S"|"1974"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"2004"|"0"|"75000"|"original distribution in many areas exceeds useful life and obsolete."|"1"|"U"|"1974"|"5"|"35000"|"original t12 technology."|"1"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"||"1"|"COMMON"|"S"|"1974"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"1"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1974"|"2"|"20000"||"STEEL"|"1"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1974"|"2"|"25000"||"0"|||||"0"||"0"|||||"0"||"U"|"U"|"0"|"1"|"1974"|"1"|"35000"|"include ovhd"|"1"|"S"|"1974"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"N"|"1974"|"10"|"0"||"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1974"|"5"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2005"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"2005"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"heating boiler used for hot water."|"1"|"S"|"2005"|"10"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2005"|"15"|"0"|"boiler is not operational due to leaks in the radiant floor piping."|"1"|"S"|"2005"|"25"|"0"||"1"|"U"|"1995"|"1"|"0"|"window a/c units."|"1"|"S"|"2005"|"15"|"0"||"1"|"U"|"2005"|"20"|"5000"|"repair leaks in the in-floor radiant piping."|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"FAIR"||"1"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"POOR"|"there is no mechanical ventilation."|"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"POOR"||"270000"|"U"|"1"|"Clark Patterson Lee"|"59 Court Street Binghamton, N.Y. 13901"|"1-800-274-9000"|"rwarholic@clarkpatterson.com"|"John J. Martin, PE"|"057961"|"I ACCEPT"|12/7/2010 2:19:11 PM| 140|"BOCES Eastern Suffolk"|"58910000"|"Brookhaven Academic Center"|"0058"|"10/21/2010"|"351 Martha Avenue"|"Bellport"|" 11713"|"ANNUAL"|"05/01/2011"|"2002"|"25100"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"179"|"9,10,11,12"|"0"|"0"|"0"|"179"|"0"|"0"|||"10"|"9000"|"ADMIN,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"6"|"0"||"1"|"SITESEPT"|"S"|"1978"|"6"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"0"||"1"|"CONCRETE"|"S"|"2002"|"7"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"|"Stair to roof only."|"0"||||"0"||"1"|"1"|"S"|"2002"|"5"|"0"||"1"|"S"|"2002"|"7"|"0"||"1"|"1"|"S"|"2002"|"6"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"6"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2002"|"7"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"6"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2002"|"10"|"0"||"1"|"S"|"2002"|"7"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"6"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"6"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"6"|"0"||"1"|"IRON,PVC"|"S"|"2002"|"6"|"0"||"1"|"ELECTRIC"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"CV"|"1"|"OTHER"|"RTU"|"S"|"2006"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"6"|"60,000"|"Subpanel not working."|"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"6"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"60,000"|"S"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/7/2010 2:40:43 PM| 141|"Morris CSD"|"47120104"|"CUSTODIAL//MAINTENANCE BUILDING"|"0002"|"04/22/2010"|"65 MAIN STREET"|"MORRIS"|" 13808"|"ANNUAL"|"06/21/2011"|"1931"|"5874"|"2"|"5"|"1"|"PART"|"OTHER_ORG"||"15"|"Pre-K"|"0"|"0"|"0"|"1"|"0"|"0"|||"1"|"840"|"OTHER"|"maintenance"|"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1951"|"10"|"0"||"1"|"SITESEPT"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1995"|"10"|"25,000"|"repairs requird at Pre-K entrance"|"1"|"CONCRETE,ASPHALT"|"S"|"1995"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1931"|"10"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"S"|"1931"|"3"|"5,500"||"1"|"S"|"1931"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1995"|"10"|"0"||"1"|"COMMON"|"S"|"1931"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1995"|"15"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"1"|"1"|"0"|"restore masonry"|"S"|"1995"|"20"|"50,000"|"restoration of masonry below stone belt coarse"|"1"|"MASONRY"|"U"|"1995"|"10"|"25,000"|"masonry restoration and recapping of chimney"|"1"|"MASONRY"|"S"|"2004"|"20"|"0"||"S"|"S"|"0"|"1"|"2001"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1995"|"15"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"20"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1951"|"10"|"0"||"1"|"IRON"|"S"|"1951"|"10"|"0"||"1"|"OIL"|"S"|"2001"|"10"|"0"||"1"|"S"|"1951"|"5"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"0"||||"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"15"|"0"||"0"||||"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"1995"|"10"|"0"||"0"||||"0"||"1"|"S"|"1995"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|||"0"|"0"||||"0"|"1"|"GOOD"||"300,000"|"U"|"0"|"Willaim Taylor Architects"|"6432 Baird ave syracuse ny 13206"|"315-432-0901"|"bill.taylor@taylor-architects.com"|"William F. Taylor"|"015542"|"I accept"|12/7/2010 3:19:00 PM| 142|"Commack USFD"|"58041003"|"NORTH RIDGE ELEMENTARY SCHOOL"|"0007"|"03/29/2010"|"TOWNLINE RD "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1962"|"63900"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"496"|"K,1,2"|"0"|"1"|"0"|"496"|"0"|"0"|||"31"|"24752"|"ADMIN,ART,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"10000"|"S"|"2009"|"35"|"0"|"Tank was replaced."|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"0"||"1"|"SITESEPT"|"S"|"1962"|"19"|"0"||"1"|"S"|"1996"|"35"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1962"|"5"|"0"||"1"|"S"|"1962"|"15"|"0"||"0"||||"0"||"1"|"S"|"1962"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1962"|"5"|"0"||"1"|"CONCRETE,ASPHALT"|"U"|"1962"|"1"|"65000"|"Replace remaining original concrete walks at front and rear of building."|"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"1962"|"19"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"25"|"0"||"1"|"S"|"1962"|"25"|"0"||"1"|"S"|"1962"|"25"|"0"||"1"|"S"|"1985"|"10"|"0"||"0"||||"0"||"1"|"U"|"U"|"1962"|"1"|"55000"|"Replace original doors as needed."|"1"|"S"|"1962"|"5"|"0"|"Stair to Boiler Room."|"0"||||"0"||"1"|"1"|"S"|"1962"|"5"|"0"||"1"|"U"|"1962"|"1"|"40000"|"Replace original Corridor fixtures."|"1"|"1"|"S"|"1997"|"12"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1985"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1985"|"10"|"0"||"1"|"COMMON"|"S"|"1962"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"Expansion joints separating"|"U"|"1962"|"15"|"10000"|"REPLACE TWO EXPANSION JOINTS AND RECAULK UV LOUVERS."|"1"|"MASONRY"|"S"|"1962"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1984"|"10"|"0"||"1"|"S"|"1962"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"25"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"1"|"1"||"U"|"1984"|"1"|"750000"|"Replace roofing adding sloping insulation and built up roofing."|"0"|||||"0"||"1"|"COPPER"|"S"|"1962"|"5"|"10000"|"Provide isolation valves."|"1"|"IRON,GALVANIZED"|"S"|"1962"|"5"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"5"|"0"||"1"|"S"|"1962"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"35"|"0"||"1"|"S"|"1996"|"35"|"0"||"1"|"U"|"1962"|"1"|"100000"|"Replace fans and air handlers."|"1"|"S"|"2007"|"25"|"0"||"1"|"S"|"1962"|"5"|"0"||"1"|"U"|"1987"|"1"|"50000"|"Provide DDC head en controller and perform pneumatic refurbishment."|"1"|"U"|"1987"|"1"|"20000"|"Reinstall pull stations to a height that will comply with ADA requirements."|"1"|"S"|"1987"|"5"|"0"||"1"|"S"|"2009"|"2009"|"0"|"System was replaced."|"0"|"S"|"1962"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"||"0"|"0"||||"1"||"GOOD"||"$ 1,100,000"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/7/2010 4:08:15 PM| 143|"North Colonie CSD"|"01062306"|"Blue Creek"|"0003"|"10/06/2010"|"100 Clinton Road"|"Latham"|"12110"|"ANNUAL"|"01/01/2011"|"1953"|"64740"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"457"|"K,1,2,3,4,5,6"|"0"|"1"|"0"|"457"|"0"|"0"|||"21"|"19410"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"S"|"1994"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"15"|"0"|"Utility vault."|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"|"MUNI"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1991"|"10"|"$250,000"|"Repair parking."|"1"|"CONCRETE,ASPHALT"|"S"|"1991"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1953"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"$50,000"|"Existing non rated corridor walls, remove gym partition."|"1"|"S"|"2004"|"15"|"0"|"Original exterior soffits."|"0"||||"0"||"1"|"S"|"S"|"2004"|"10"|"$35,000"|"Original doors non rated/ADA."|"1"|"S"|"1953"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1997"|"20"|"$20,000"|"Replace stage lighting."|"1"|"1"|"S"|"2010"|"10"|"0"|"PA upgraded 2010, Bogden"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"$185,000"|"Classroom VAT, corridor VCT ok, gym athletic tile OK."|"1"|"COMMON"|"S"|"2004"|"15"|"0"|"Bathrooms"|"0"|||||"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Mezzanine concrete deck"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"S"|"2004"|"5"|"$115,000"|"Replace '91 comp. panels, replace transite soffits, replace spawled brick."|"1"|"MASONRY"|"S"|"2009"|"20"|"0"|"Repointed '09."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"$12,000"|"Replace HM doors at '91 wing."|"1"|"S"|"1953"|"10"|"$5,000"|"Replace abrasion strips at gym."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1998"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"$100,000"|"Reroof '91 wing."|"0"|||||"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2004"|"10"|"$75,000"|"Replace galvanized piping."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2004"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"10"|"0"||"1"|"S"|"2004"|"10"|"$30,000"|"Replace original toilet with accessible type (near boiler room)."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1994"|"20"|"0"|"(3) Weil McClain"|"1"|"S"|"1994"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"5"|"$705,000"|"Improve ventilation at timeout room. Replace gym/cafeteria AHUs. UVs planned for 2011."|"1"|"S"|"2004"|"10"|"$30,000"|"Replace oil bath pumps, hall convectors."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"|"DDC upgrade planned for 2011."|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"2004"|"2004"|"0"|"Kitchen only."|"1"|"S"|"2004"|"15"|"$15,000"|"Upgrade corridor coverage."|"0"||||"0"||"1"|"1"|"75,000"|"Staff ADA toilet at '04 wing auto opener $5K"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"2,092,000"|"S"|"1"|" CSArch "|"40 Beaver Street, Albany, NY 12207"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I ACCEPT"|12/7/2010 4:21:55 PM| 144|"Bethpage UFSD"|"28052103"|"BETHPAGE HIGH SCHOOL"|"0001"|"8/4/2010"|"10 CHERRY AVENUE"|"BETHPAGE"|" 11714"|"ANNUAL"|"4/1/2010"|"1959"|"316,474"|"3"|"13"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"1012"|"9,10,11,12"|"0"|"1"|"1"|"1012"|"0"|"0"|||"45"|"36,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"2"|"20,000"|"S"|"1990"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1986"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"0"||"1"|"CONCRETE"|"S"|"2010"|"15"|"0"|"Replace concrete sidewalk around 1960's addition & curbing along Baseball Fields."|"0"||||"0"||"1"|"E"|"2010"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"20"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"|"Several large cracks of music suite, auxiliary gym that should be monitored."|"1"|"S"|"2003"|"5"|"823,600"|"Recommend replacement of remaining concealed spline ceilings."|"1"|"E"|"2010"|"15"|"0"|"Original lockers remain outside Room 121 hallway."|"1"|"S"|"S"|"2003"|"6"|"307,660"|"Recommend replacement of doors throught building."|"1"|"S"|"1967"|"15"|"0"|"Existing railing spacing exceeds 4" maximum clearance."|"1"|"E"|"2010"|"25"|"0"||"1"|"1"|"E"|"2004"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"1"|"E"|"2004"|"15"|"0"||"1"|"E"|"2009"|"20"|"148,000"|"Recommend replacementof existing asbestos plaster soffits."|"1"|"COMMON"|"S"|"2008"|"6"|"56,000"|"Recommend replacement of 7 carpet over VAT. "|"1"|"INSTRUCT"|"S"|"2009"|"10"|"235,000"|"Recommend removal of remaining VAT"|"1"|"COMMON"|"S"|"1967"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2007"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2010"|"25"|"8,000"|"Parge foundation walls at lower exterior stairwell."|"1"|"MASONRY"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"E"|"E"|"1"|"1"|"2004"|"15"|"0"||"1"|"S"|"1967"|"15"|"12,000"|"Replace exterior railings at Gym entrance."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"15"|"0"||"WOODONMET,CONMETMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1967"|"10"|"0"||"1"|"IRON"|"S"|"2010"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1985"|"10"|"0"||"1"|"S"|"2010"|"15"|"0"||"0"||"1"|"BOILERSTEA"||"E"|"2010"|"35"|"0"||"1"|"E"|"2010"|"35"|"0"||"1"|"E"|"2008"|"25"|"0"||"1"|"S"|"1967"|"5"|"245,000"|"All student occupied spaces shall be mechanically ventilated."|"1"|"S"|"1967"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"5"|"58,000"|"Recommend pneumatic refurbishment"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2000"|"2000"|"0"|"Last inspection 2/2010"|"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"1986"|"10"|"12,000"|"Routing of generator exhaust shold be extended above the roof."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"FIREALARM"|"FULL"|"1"|"1"||"GOOD"||"1,945,260.00"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/7/2010 4:26:16 PM| 146|"Commack USFD"|"58041003"|"MAINTENANCE OFFICE (B&G)"|"1002"|"02/16/2010"|"BURR ROAD "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1972"|"1500"|"1"|"0"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"14"|"0"||"1"|"SITESEPT"|"S"|"1972"|"19"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1972"|"32"|"0"||"1"|"S"|"1972"|"19"|"0"||"0"||||"0"||"1"|"S"|"1972"|"19"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"24"|"0"||"1"|"CONCRETE"|"U"|"1972"|"5"|"2000"|"Replace walk next to Entry."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"29"|"0"||"1"|"S"|"1972"|"29"|"0"||"1"|"S"|"1972"|"29"|"0"||"1"|"S"|"1972"|"9"|"0"||"0"||||"0"||"1"|"S"|"S"|"1972"|"9"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"29"|"0"||"1"|"S"|"1972"|"9"|"0"||"1"|"1"|"S"|"2000"|"9"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"9"|"0"||"1"|"COMMON"|"S"|"1972"|"9"|"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1972"|"9"|"0"||"WOODJOIST"||"1"|"0"|"0"|"1"|"0"||"0"|"0"|"0"|"S"|"1972"|"24"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"14"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"19"|"0"||"1"|"S"|"1972"|"19"|"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1972"|"9"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"19"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1972"|"29"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1972"|"29"|"0"||"1"|"ELECTRIC"|"S"|"1972"|"9"|"0"||"1"|"S"|"1972"|"29"|"0"||"0"||"1"|"OTHER"||"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"5"|"0"||"0"|"NF"|"1972"|"1"|"20000"|"Install new system."|"0"|"NF"|"1972"|"3000"|"0"|"Install smoke detection system."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"0"|"30000"|"Improvements to comply with ADA requirements."|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 55,000"|"U"|"0"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/7/2010 5:37:06 PM| 147|"Afton CSD"|"08010104"|"Bus Garage"|"0003"|"11/10/2010"|"18 SAND ST "|"AFTON "|" 13730"|"ANNUAL"|"11/01/2011"|"1955"|"7400"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus Garage Maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"1"|"1000"|"0"|"0"|"S"|"2002"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"20"|"0"||"1"|"SITESEPT"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"2002"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"S"|"2002"|"10"|"0"||"1"|"S"|"1955"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|"S"|"1987"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"5"|"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"1"|"MASONRY"|"S"|"2002"|"15"|"0"||"0"|"N/A"||||"0"||"S"|"S"|"0"|"1"|"2002"|"0"|"0"||"1"|"S"|"1955"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"10"|"0"||"METONMET,WOODONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON"|"S"|"2002"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||"1"|"BOILERWATE"||"U"|"1955"|"1"|"$50000"|"Being Replaced by the District 2011"|"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"|"Simple Exhaust Fans"|"1"|"S"|"2002"|"30"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"|"Local Electric Controls"|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"|"Devices tied into and reports to Main School Building across the street"|"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"0"|"GOOD"||"$50,000"|"U"|"1"|"Bivens Architects"|"528 Plum Street, Syracuse, NY 13204"|"3157030987"|"tbivens@bivensarchitects.com"|"Timothy R. Bivens"|"30400371"|"I ACCEPT"|12/8/2010 10:22:32 AM| 149|"Greenwood Lake UFSD"|"44211102"|"Greenwood Lake Elementary School"|"0002"|"5/6/10"|"WATERSTONE ROAD "|"GREENWOOD LAKE "|" 10925"|"ANNUAL"|"2/1/11"|"1927"|"38,194"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"251"|"K,1,2"|"0"|"0"|"0"|"251"|"0"|"0"|||"13"|"11312"|"ADMIN,CAFE,GYM,KITCHEN,LIBBRARY,SPECED"||"1"|"0"|"0"|"1"|"12,000"|"S"|"1960"|"10"|"10,000"|"Replace manway cover with water tight assembly. Cost includes cutting/patching concrete pad over existing tank."|"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"|"Water service appears to be in satisfactory condition."|"1"|"SITESEPT"|"S"|"2008"|"20"|"2,000"|"Sanitary service appears to be in satisfactory condition. Perimeter chainlink fence at leach field needs to be repaired at west corner."|"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2004"|"30"|"0"||"1"|"S"|"1993"|"0"|"4,000"|"Clean debris from four catch basins and one trench drain, flush pipes until water flows freely."|"0"||||"0"||"1"|"S"|"1960"|"5"|"4,000"|"Repair and adjust heights of catch basins to reflect adjacent grades."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1993"|"5"|"211,500"|"North Parking - Remove and replace with auto duty asphalt. South Play Area - Remove and replace with auto duty asphalt. South Parking - Remove and replace with auto duty asphalt. Preliminary study and testing required."|"1"|"CONCRETE"|"S"|"1993"|"10"|"0"|"Walks appear to be in satisfactory condition."|"1"|"U"|"2004"|"2"|"26,000"|"Replace mulch at playground equipment with 10" engineered mulch 4,800 SF. Remove overgrown garden area grade, topsoil and sod area 6,500 SF."|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1993"|"42"|"0"||"1"|"S"|"1993"|"35"|"0"||"1"|"S"|"1993"|"25"|"22,500"|"Provide wall pads where on Gym walls. Improve gym acoustics by installing acoustical wall panels."|"1"|"S"|"1993"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1993"|"25"|"2,450"|"Provide closers on doors in the original building first floor."|"1"|"S"|"1960"|"35"|"0"||"1"|"E"|"2004"|"70"|"0"||"1"|"1"|"E"|"2004"|"20"|"55,700"|"Replace remaining older panels not replaced in 2004. Provide new stage dimming system with lighting fixtures and border lighting."|"1"|"S"|"2004"|"20"|"24,800"|"Replace all interior and exterior metal halide lighting with new LED lighting."|"1"|"1"|"S"|"2004"|"15"|"198,700"|"Provide new video on demand. Upgrade 50% of network electronics. Provide additional CCTV devices. Provide interactive whiteboard or 50" LCD display."|"0"||||"0"||"1"|"COMMON"|"S"|"1993"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1993"|"20"|"0"||"1"|"COMMON"|"S"|"1960"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1960"|"20"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1993"|"22"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"17"|"0"||"1"|"MASONRY"|"S"|"1960"|"30"|"0"||"1"|"MASONRY"|"S"|"1993"|"20"|"0"||"S"|"S"|"0"|"1"|"2004"|"28"|"0"||"1"|"S"|"2009"|"50"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"30"|"0"||"METONMET"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"12"|"0"||"1"|"PLASTIC"|"S"|"2004"|"12"|"0"||"1"|"COPPER"|"S"|"2004"|"15"|"0"|"Water distribution system appears to be in satisfactory condition."|"1"|"IRON,COPPER"|"S"|"2004"|"15"|"0"|"Plumbing drainage systems appear to be in satisfactory condition."|"1"|"OIL"|"S"|"2004"|"10"|"0"|"Water heater appears to be in satisfactory condition."|"1"|"S"|"2004"|"10"|"12,500"|"Replace flush valves, seats, faucets and traps (9 toilet rooms). Replace wall mounted service sink with floor mounted in Janitor's closet"|"0"||"1"|"BOILERWATE"||"E"|"2004"|"19"|"0"||"1"|"E"|"2004"|"14"|"0"||"1"|"S"|"2004"|"14"|"0"||"1"|"E"|"2004"|"24"|"0"||"1"|"E"|"2004"|"44"|"0"||"1"|"E"|"2004"|"34"|"0"||"1"|"E"|"2004"|"19"|"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"S"|"1960"|"1960"|"0"|"Consider removing hoses from fire hose cabinets in the corridor. Work by Owner."|"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"187,400"|"Provide new emergency generator to pwoer entire facility."|"1"|"1"|"2200"|"Provide accessible signage throughout. Currently only provided at toilet rooms and elevator."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"Improve gym acoustics by installing acoustical wall panels (cost accounted for on Line 46)."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"|"0"|"1"||"GOOD"||"992,875"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road"|"607-277-7100"|"info-ae@tetratech.com"|"Alton Ainslie"|"024351"|"I ACCEPT"|12/8/2010 10:44:18 AM| 151|"Greenwood Lake UFSD"|"44211102"|"Greenwood Lake Middle School"|"0001"|"05/06/2010"|"1247 LAKES RD "|"GREENWOOD LAKE "|" 10925"|"ANNUAL"|"02/01/2011"|"1970"|"82000"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"336"|"3,4,5,6,7,8"|"1"|"0"|"0"|"336"|"0"|"0"|||"22"|"17240"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,SCIENCELAB,SPECED,TECHSHOP"||"0"||||||||"0"||"1"|"WELL"|"S"|"1973"|"17"|"3000"|"Water service appears to be in satisfactory condition, but has slight discoloration could be magnesium. Water should be tested for quality, sedimetn types and levels. New pump and booster in 2007."|"1"|"SITESEPT"|"S"|"1973"|"7"|"0"|"Sanitary service appears to be in satisfactory condition. New pump in 2008."|"1"|"S"|"1973"|"10"|"0"|"Gas service appears to be in satisfactory condition."|"1"|"UTIL"|"BELOW"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"0"|"0"|"See item #33."|"1"|"S"|"1973"|"0"|"$5,000"|"Clean and re-define swales, add armor with rip-rap."|"1"|"S"|"1973"|"0"|"$29,000"|"Two catch basins recently failed/collapsed and were replaced by school. It is recommended that five remaining cat basins be replaced. Drain inlets in lawn areas should be cleaned to allow for proper performance."|"1"|"S"|"1973"|"15"|"$700"|"The end of culvert pipe is blocked and needs to be cleaned to allow for proper drainage. End of culvert should be armored with rip-rap."|"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1973"|"10"|"$26,000"|"Pond never dredged, testing, comm. w/ NYSDEC,permitting&study of original design volume vs current to determine if dredging required. Pond fed by & flows into trout stream. Maintenance/debris removal. Repair utility gates & footings."|"0"||||"0"||"1"|"ASPHALT"|"U"|"1995"|"5"|"$424,950"|"S lot-mill & retop asphalt. W lot-poor cond-full remove & replace w/ auto duty asphalt. Bus loop-poor condition-full remove & replace w/ heavy duty asphalt. Reset catch basin rims in area of new asphalt. Gravel access road good condition."|"1"|"CONCRETE"|"S"|"1995"|"3"|"$25,000"|"140x10ft concrete walk heaved & cracked where meets curb creates tripping hazard. Remove & replace area & cracked at main entrance. Small section of granite cobble curb is missing at bus loop. Remove & update 6 benches at main entrance."|"1"|"S"|"1995"|"0"|"$8,000"|"Rubber mulch at playground equipment is migrating out of the play area and should be replaced with 10ft of engineered mulch."|"1"|"S"|"1973"|"5"|"$53,000"|"N"|"Ponding issue between basketball court and basebal backstop. Regrading & drain inlet w/ piping connected to existing drainage system required. Baseball home and visitor Dugouts. Softball home and visitor Dugouts."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1997"|"69"|"0"||"1"|"S"|"1997"|"49"|"0"||"1"|"S"|"1997"|"49"|"$16,000"|"Replace 4 original manually operated basketball backbaords with new motorized units."|"1"|"S"|"1997"|"10"|"$3,150"|"Vinyl faced ceiling in kitchen is old and worn. Replace in-kind."|"1"|"U"|"1973"|"10"|"$75,000"|"Replace old, damaged locker room lockers in both Boy's and Girls Room."|"1"|"S"|"S"|"1997"|"10"|"$5,000"|"Since the loading dock houses gas powered equipment, the door opening to the corridor should be 1 1/2 hr fire rated. Replace double door and frame with rated unit."|"1"|"S"|"1997"|"49"|"$8,750"|"Handrails in the northernmost stairway are 2x6 wood. Provide rounded metal handrail mounted to the existing wood rail to improve grasping especially for disabled users."|"1"|"S"|"1997"|"65"|"0"||"1"|"1"|"S"|"1995"|"15"|"$141,700"|"Replace remaining elec panels orig to bldg, not replaced in 1995. Provide single phase & brown out protection on main service. Replace low voltage switching w/ new line. Provide new stage dimming/lighting control system incld new fixtures."|"1"|"S"|"2000"|"10"|"$185,600"|"Replace: t-12 w/ T-8/T-5 ltg. Existing metal halide/mercury vapor int. ltg. w/ LED. Ext. ltg. w/ LED, incl. bldg mounted & pole ltg. Remaining incandescent & fluorescent exit ltg. w/ LED. Provide ext.controls for bldg mounted & pole ltg."|"1"|"1"|"S"|"2009"|"15"|"$439,100"|"Provide: Video on Demond w/ IP delivery of video&10TB server. Add CCTV devices. Interactive whiteboard/LCD in rooms w/o IWB or LCD. Stage/Cafe. sound system incld wireless mic/assistive listening. Upgrade 50% network electronics w/ gigabit PoE "|"0"||||"0"||"1"|"INSTRUCT"|"S"|"1973"|"2"|"$6,000"|"Replace Music Room Carpet."|"1"|"INSTRUCT"|"S"|"1997"|"15"|"0"||"1"|"COMMON"|"S"|"1973"|"20"|"0"||"1"|"COMMON"|"S"|"1973"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1997"|"49"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"1997"|"44"|"0"||"1"|"MASONRY"|"S"|"1973"|"44"|"0"||"1"|"MASONRY"|"S"|"1997"|"44"|"0"||"E"|"E"|"1"|"1"|"1997"|"20"|"0"||"1"|"S"|"1997"|"30"|"0"|"Railroad tie stairs at rear of building are scheduled for replacement."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"10"|"0"||"CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"0"||"1"|"PLASTIC"|"S"|"1997"|"10"|"0"||"1"|"COPPER"|"S"|"1995"|"15"|"$195,000"|"Replace: gate valve w/ ball/butterfly, 2,000gal water storage tank & air compressor w/ vsd booster pump sys & smaller storage tank. Add water filtration system wo well water line prior to entering 15,000gal buried water storage tank."|"1"|"IRON,COPPER,PVC"|"S"|"1995"|"51"|"0"|"Plumbing drainage system appears to be in satisfactory condition."|"1"|"NAT_GAS"|"S"|"2004"|"7"|"$18,500"|"Remove abondoned 1,500gal hot water storage tank & relocate existing water heater to location to improve system operation & maintenance. Price includes abating existing abondoned storage tank."|"1"|"S"|"2004"|"10"|"$27,500"|"Replace flush valves, seats, faucets, supplies, traps. Add emergency eyewash incl TMV to Tech classrm. Replace sinks and bubbler units in Kindergarten classrms, do not meet current sanitary code. "|"0"||"1"|"BOILERWATE"||"S"|"1996"|"11"|"$18,000"|"All cast iron sections replaced in 2009. Provide power exhaust system in boiler roomto prvent heat build up. Includes new wall opening."|"1"|"S"|"1973"|"5"|"$24,000"|"Powerflame burners (2) are workign but are past their useful life & recommended replacement. Provide new burners w/ full modulation w/ new controls & DDC interface. Cost includes electrical & plumbing work. "|"1"|"S"|"1973"|"5"|"0"|"Cooling system is functioning but past its useful life & recommend replacement. Provide new cooing system w/ new condensor on roof w/ evaporator barrel inside to match existing system. Cost is included in #78."|"1"|"S"|"1997"|"5"|"$2,660,000"|"Original bldg 1973, equip.is near end of useful life. 1997 add. equip. remain. Provide heating & cooling equip. for 1973 bldg, classrms, gym, cafe., stage, music, office, piping, etc. include chiller & controls. Cost include GC,EC,asbestos work."|"1"|"S"|"1997"|"13"|"0"|"Piping appears to be in satisfactory condition but nearing the end of its useful life in teh 1973 portion of the building. Cost to replace the original piping is included in item #78."|"1"|"S"|"1997"|"5"|"0"|"The ductwork serving the original 1973 building is nearing the end of its useful life. The cost to replace original ductwork is included in item #78."|"1"|"S"|"1997"|"5"|"0"|"The pneumatic controsl serving the original 1973 building is nearing the end of its useful life. The cost to replace original controls is included in item #78."|"1"|"S"|"1995"|"5"|"$176,300"|"Replace existing zoned fire alarm system w/ new addressable system. Additional fire alarm strobe lights to meet ADA standards,. Additional fire alarm ehat detectors in art rooms & some storage rooms."|"1"|"S"|"1995"|"5"|"$43,700"|"Replace all existing smoke detectors and add addtional detectors as part of system replacement."|"1"|"S"|"1995"|"1995"|"0"|"Fire suppression system at kitchen hood appears to be in satisfactory condition, review in another 5 years."|"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"1"|"1"|"4675"|"Provide accessible signage througout. Currently only provided at toilet rooms and elevator."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"0"|"1"||"GOOD"||"$6,511,603"|"E"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road"|"607-277-7100"|"info-ae@tetratech.com"|"Alton Ainslie"|"024351"|"I ACCEPT"|12/8/2010 11:01:24 AM| 152|"Morris CSD"|"47120104"|"MAIN BUILDING"|"0001"|"04/22/2010"|"65 MAIN STREET"|"MORRIS"|" 13808"|"ANNUAL"|"06/21/2011"|"1931"|"102510"|"2"|"0"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"476"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"29"|"0"|"0"|||"25"|"19,216"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1982"|"15"|"0"||"1"|"SITESEPT"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"|"Above ground LP tanks"|"1"|"UTIL"|"BELOW"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2001"|"10"|"250,000"|"Expansion of parking are in front of the 1931 building"|"1"|"CONCRETE"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"1,200,000"|"Y"|"Construction of new synthetic track and associated site modifications"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"5,000"|"Elementary gym walls-plaster damage needs repairing"|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"S"|"2001"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"1"|"S"|"2001"|"10"|"100,000"|"Replacement of existing clock system"|"1"|"S"|"2001"|"10"|"0"||"1"|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2001"|"15,3"|"100,000"|"Replace elementary gym floor"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"masonry repointing"|"S"|"2001"|"20"|"25,000"|"masonry repointing of areas of exterior brick"|"1"|"MASONRY"|"S"|"2004"|"15"|"0"||"1"|"MASONRY"|"S"|"2001"|"20"|"0"||"S"|"S"|"0"|"1"|"2001"|"15"|"100,000"|"Entry doors in 1931 building and access door to clock need to be replaced-add additional doors to the existing keyless entry system"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1"|"1995"|"15"|"0"||"0"|"ALUMINUM"|"S"|"Y"|"2001"|"15"|"0"||"METONMET,WOODONMET"|"SINGLEPLY,BUILTUP,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"200,000"|"Planned replacement of 1995 single ply roof membrane"|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2001"|"10"|"10,000"|"Approximately 20 unions need to be replaced as they are leaking (possibly manufacturing issue)"|"1"|"IRON"|"S"|"2001"|"15"|"0"||"1"|"OIL"|"S"|"2001"|"5"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"|"AC limited to offices, cafeteria and library"|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"15"|"7,500"|"1931 building has some original valves and traps that will need replacing"|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"75,000"|"Replace 1931 and 1995 sections to provide a fully addressable system"|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2001"|"10"|"0"||"0"|"NF"|||"150,000"|"provide emergency generator for main building"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"1"|"0"|"1"|"GOOD"||"3,000,000"|"U"|"0"|"William Taylor Architects"|"6432 Baird Ave Syracuse NY 13206"|"315-432-0901"|"Bill.taylor@taylor-architects.com"|"William F.Taylor"|"015542"|"I accept"|12/8/2010 11:27:47 AM| 154|"Union Springs CSD"|"05190104"|"Bus Garage"|"5003"|"7/13/10"|"39 Grove Street"|"Union Springs"|" 13160"|"ANNUAL"|"10/1/10"|"1964"|"6327"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Vehicle maintenance/offic "|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1998"|"20"|"0"|"Pump replaced in 2008."|"1"|"MUN_UTILIT"|"S"|"1997"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"15"|"0"|"(NYSEG)"|"1"|"UTIL"|"ABOVE"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"10"|"4,000"|"Recommend cleaning rip-rap lined drainage channel of vegetation"|"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"ONSITE,OTHER"|"discharge to daylight within property"|"1"|"S"|"1998"|"10"|"4,000"|"Recommend cleaning rip-rap lined drainage ditch of vegetation"|"0"||||"0"||"1"|"S"|"1998"|"10"|"13,000"|"Recommend dredging basin to improve storage capacity"|"0"||||"0"||"1"|"S"|"1998"|"10"|"0"|"Existing oil separator"|"1"|"ASPHALT,GRAVEL"|"S"|"1998"|"15"|"70,000"|"Owner requested expanding parking areas (10 cars); Re-stripe & seal cracks"|"1"|"CONCRETE"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"25"|"0"||"1"|"S"|"1998"|"30"|"0"||"1"|"S"|"1998"|"25"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"U"|"S"|"1998"|"5"|"7,000"|"Recommend replacing (2) doors/frames @ wash bay."|"0"||||"0"||"1"|"S"|"2008"|"30"|"0"|"Routine inspection & maintenance of vehicle lifts."|"1"|"1"|"S"|"1998"|"15"|"0"||"1"|"U"|"1998"|"5"|"14,000"|"HPS light voltage drop issue; replace (18) 400w HPS w/ fluorescent"|"1"|"1"|"S"|"1998"|"15"|"105,000"|"Owner recommend connecting to AJ Elementary server LAN via fiber (ethernet gear"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"|"Minor settlement cracks (normal)"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"30"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1998"|"5"|"2,000"|"Recommend district re-caulk misc. control joints."|"1"|"METAL"|"S"|"1998"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"5"|"7,000"|"Replace (2) hollow metal doors & door hardware; replace weatherstripping."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1998"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1998"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"|"RTU unit w/ A/C for offices"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"10"|"0"|"local controls"|"1"|"S"|"1998"|"10"|"1,000"|"Recommend adding visual strobes in toilet rms. connect to existing 4-zone FCI FACP"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"80,000"|"Recommend adding generator (fuel pumps, garage doors, some lighting, fire alarm)"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"GOOD"||"307,000"|"S"|"1"|"King + King Architects"|"358 West Jefferson St. Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I accept"|12/8/2010 11:48:31 AM| 155|"Hadley-Luzerne CSD"|"63080104"|"Administration Building"|"1005"|"10/21/2010"|"27 Ben Rosa"|"Lake Luzerne"|" 12846"|"ANNUAL"|"01/01/2011"|"1900"|"3800"|"2"|"0"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"275"|"0"|"0"|"S"|"1990"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1985"|"10"|"0"||"1"|"SITESEPT"|"S"|"1985"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1985"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1985"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1985"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1900"|"10"|"0"||"1"|"S"|"1900"|"20"|"0"||"1"|"S"|"1900"|"10"|"0"||"1"|"S"|"1900"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1900"|"5"|"0"||"1"|"S"|"1900"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"1985"|"5"|"0"|"In process of energy performance project"|"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1970"|"2"|"7500"|"Carpet needs to be replaced in office areas"|"1"|"COMMON"|"S"|"1970"|"5"|"0"||"1"|"COMMON"|"S"|"1900"|"10"|"0"||"1"|"COMMON"|"S"|"1900"|"10"|"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1900"|"10"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1900"|"5"|"0"|"Exterior cladding will need to be replaced with in the next 5yrs."|"1"|"MASONRY"|"S"|"1900"|"6"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1985"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"1"|"1985"|"10"|"0"||"1"|"WOOD"|"U"|"NA"|"1900"|"1"|"30,000"|"All existing windows need to be replaced."|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"8"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1985"|"10"|"0"||"1"|"GALVANIZED,LEAD,PVC"|"S"|"1985"|"10"|"0"||"1"|"ELECTRIC"|"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"OTHER"|"1"|"BOILERWATE"||"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1995"|"5"|"0"|"Units are individual window units."|"1"|"S"|"1985"|"5"|"0"||"1"|"S"|"1985"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1985"|"10"|"0"|"Building has individual smoke detectors."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"1"|"AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"1"|"0"||||"1"||"GOOD"||"$37,500"|"S"|"1"|"Re4orm Architecture"|"323 Clinton St., Schenectady, NY 12305"|"518-399-4174"|"mike@re4ormarchitecture.com"|"Mike Gamache"|"0306521"|"I ACCEPT"|12/8/2010 12:03:11 PM| 156|"BOCES Eastern Suffolk"|"58910000"|"Sherwood Support Center"|"1050"|"10/19/2010"|"15 Andrea Road"|"Holbrook"|" 11741"|"ANNUAL"|"05/01/2011"|"1988"|"49850"|"1"|"7"|"0"|"LSD_DIST"|"DIST_ADMIN,OTHER"|"Conferences, staff meetings, etc"|"0"|||"0"|"0"||||||"0"|"0"|"ADMIN,MULTIPURPO"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"6"|"0"||"1"|"SITESEPT"|"S"|"1988"|"6"|"0"||"1"|"S"|"1988"|"6"|"0"||"0"|"UTIL"|"BELOW"|"S"|"1988"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1988"|"6"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"7"|"0"||"1"|"CONCRETE"|"S"|"2007"|"14"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"6"|"0"||"1"|"S"|"1988"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"S"|"2004"|"6"|"0"||"0"||||"0"||"1"|"S"|"S"|"2007"|"9"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"6"|"0"||"1"|"S"|"2004"|"6"|"0"||"1"|"1"|"S"|"2005"|"6"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"9"|"0"||"1"|"COMMON"|"S"|"2008"|"9"|"0"||"1"|"COMMON"|"S"|"2008"|"9"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"6"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"6"|"0"||"1"|"METAL"|"S"|"1988"|"6"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1988"|"6"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1988"|"6"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1988"|"6"|"0"||"1"|"GALVANIZED,OTHER"|"S"|"1988"|"6"|"0"||"1"|"ELECTRIC"|"S"|"1988"|"6"|"0"||"1"|"S"|"2004"|"6"|"0"||"1"|"CV"|"1"|"OTHER"|"RTU"|"S"|"2007"|"6"|"0"||"1"|"S"|"1988"|"6"|"0"||"1"|"S"|"1988"|"6"|"0"||"1"|"S"|"1988"|"6"|"0"||"0"||||"0"||"1"|"S"|"1988"|"6"|"0"||"1"|"S"|"2002"|"9"|"0"||"1"|"S"|"2002"|"9"|"0"||"1"|"S"|"2002"|"9"|"0"||"1"|"S"|"2008"|"2008"|"0"||"1"|"S"|"2002"|"6"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"0"|"E"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/8/2010 12:26:18 PM| 157|"Afton CSD"|"08010104"|"Bus Garage Annex"|"4006"|"11/10/2010"|"Court Street"|"Afton"|"13730"|"ANNUAL"|"11/01/2011"|"1955"|"6500"|"1"|"1"|"0"|"DISTRICT"|"OTHER"|"Bus Storage Garage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"1"|"275"|"0"|"0"|"U"|"1987"|"10"|"$2,000"|"Oil Piping System is Unsatisfactory, Fuel Tank is Satisfactory"|"1"|"MUN_UTILIT"|"S"|"1955"|"5"|"0"||"1"|"SITESEPT"|"S"|"1955"|"5"|"0"||"0"||||"0"||"0"|"UTIL"|"ABOVE"|"CF"|"1955"|"0"|"$8,000"|"Obsolete electric panel (Federal Pacific type) in poor condition and circuit breakers (stab-lok type) are considered a fire hazard"|"0"||||"0"||"0"||||"0"||"1"|"S"|"1955"|"5"|"0"|"Not allowable by current DEC requlations for a non-municipal system"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"1"|"0"|"1"|"1"|"1"|"0"|"U"|"1955"|"1"|"$75,000"|"Undermining at column piers between doors, horizontal and vertical cracking at areas below grade"|"1"|"S"|"1955"|"5"|"0"||"0"||||"0"||"1"|"U"|"1955"|"1"|"$35,000"|"Existing fiberous ceiling is water damaged and sagging"|"0"||||"0"||"0"|"U"|"U"|"1955"|"1"|"$6,000"|"No ADA hardware, door closers and doors bind in frames."|"0"||||"0"||"0"||||"0"||"1"|"0"|"U"|"1955"|"5"|"$30,000"||"1"|"U"|"1955"|"1"|"$15,000"||"0"|"1"|"S"|"1955"|"1"|"$4,000"|"Single telephone handset present"|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1955"|"5"|"0"|"Many areas of patching required"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1955"|"5"|"0"||"MASONRY"|"1"|"1"||"1"|"1"|"0"|"1"|"1"||"U"|"1955"|"5"|"$75,000"||"1"|"MASONRY"|"U"|"1955"|"1"|"$15,000"||"0"|||||"0"||"U"|"U"|"0"|"0"|"1955"|"1"|"$20,000"|"Overhead doors are in poor condition and the operators are not code compliant"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1955"|"1"|"$8,000"||"METONMET,OTHER"|"ASPHALT"|"1"|"0"|"1"|"1"|"0"||"0"|"0"|"1"|"1"|"1"|"0"|"0"|"0"||"U"|"1987"|"1"|"$200,000"||"0"|||||"0"||"1"|"COPPER,PVC"|"S"|"1955"|"10"|"0"||"0"|"IRON"|"S"|"1955"|"5"|||"1"|"OIL"|"S"|"1987"|"10"|"0"||"1"|"U"|"1955"|"5"|"$5,000"|"Single Toilet/Lavatory, Outdated"|"0"||"1"|"FURNACE"||"S"|"1955"|"5"|"$15000"|"2 older Oil Fired Unit Heaters"|"1"|"U"|"1955"|"5"|"$6,000"|"Poorly Supported, unsupported copper/plastic system"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"$3,000"||"0"||||"0"||"1"|"0"|"25000"|"Restroom reconstruction"|"POOR"||"POOR"||"0"|"0"|"FAIR"||"FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"walls of garage"|"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"POOR"||"1"|"0"|"1"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"POOR"|"Un sage OSHA separation of vehicles and personnel. Overhead doors inadequate for intended use/size. Bay sizes too samll for safety"|"500,000"|"U"|"1"|"Bivens Architects"|"528 Plum Street, Syracuse, NY 13204"|"3157030987"|"tbivens@bivensarchitects.com"|"Timothy R. Bivens"|"30400371"|"I ACCEPT"|12/8/2010 12:58:13 PM| 158|"BOCES Madison-Oneida"|"25900000"|"Sawmill/Sap House"|"0007"|"08/16/2010"|"SPRING ROAD "|"VERONA "|" 13478"|"ANNUAL"|"08/15/2011"|"1992"|"3697"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Sawmill/sap house"|"40"|"10,11,12"|"0"|"0"|"0"|"40"|"0"|"0"|||"2"|"1200"||"Storage/trash compactor"|"0"||||||||"0"||"0"|"OTHER"|"S"|||"0"||"0"|||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"UTIL,SELF"|"BELOW"|"S"|"2002"|"17"|"0"||"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"11"|"0"||"1"|"CONCRETE"|"S"|"2002"|"11"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"21"|"0"||"1"|"S"|"2002"|"15"|"0"|"Chimney Flashing is leaking. *Update-the leak has been repaired. "|"1"|"S"|"2002"|"15"|"0"||"0"|"S"|"2002"|"12"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"11"|"0"||"1"|"S"|"2002"|"11"|"0"||"0"|||||"0"|"not required for function"|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"8"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"21"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"6"|"0"|"needs to be stained"|"1"|"METAL"|"S"|"2002"|"5"|"5000"|"Chimney flashing is leaking. *update- we fixed the leak that was in the flashing for the evaporator."|"0"|||||"0"||"S"|"S"|"0"|"0"|"2002"|"4"|"2000"|"Most doors are in poor shape and will need to be replaced"|"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"2002"|"4"|"6000"|"Only a few new windows were installed as part of the 2002 project and most need to be replaced."|"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"0"|"Chimney flashing leaks. *Update-we have fixed the leak"|"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"1"|"FURNACE"||"S"|"2002"|"8"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"LIGHTING"|||"1"|"1"|"GOOD"||"10000"|"S"|"1"|"William J.Murphy co"|"303 Noyes BLVD, Sherrill NY 13461"|"315-363-3682"|"murphy@twcny.rr.com"|"William J. Murphy"|"041799"|"I accept"|12/8/2010 2:33:32 PM| 159|"Penn Yan CSD"|"68060106"|"Penn Yan Middle School"|"0003"|"7/8/10"|"515 Liberty Street"|"Penn Yan"|" 14527"|"ANNUAL"|"9/1/10"|"1929"|"87000"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Community use"|"432"|"6,7,8"|"0"|"1"|"0"|"432"|"0"|"0"|||"18"|"11945"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"20"|"0"||"1"|"S"|"1994"|"45"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1994"|"30"|"0"|"1600 amp Square D 120/208v MCP/MDP"|"1"|"S"|"1994"|"20"|"0"||"0"||||"0"||"1"|"S"|"1994"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1929"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"|"Installed @ gym area."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1994"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1994"|"20"|"0"||"0"||||"0"||"1"|"S"|"2000"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1994"|"20"|"0"||"1"|"S"|"1994"|"20"|"0"||"1"|"U"|"1994"|"5"|"240000"|"District is considering reconfiguring Main office"|"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"2005"|"30"|"0"||"1"|"U"|"S"|"1994"|"5"|"86000"|"Recommend replacing (29) original classroom doors"|"1"|"S"|"1994"|"5"|"5000"|"Recommend replacing stair treads"|"1"|"S"|"1994"|"20"|"0"||"1"|"1"|"S"|"1994"|"30"|"0"||"1"|"U"|"1990"|"5"|"210000"|"Recommend replacing T-12 & Metal Halide fixtures (energy efficiency)"|"1"|"1"|"U"|"2004"|"5"|"105000"|"Recommend expanding district-wide VOIP system to Bldg. (Existing Primex wireless clocks)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2005"|"5"|"93000"|"Recommend replacing carpet @ 3rd floor classrooms & Auditorium"|"1"|"INSTRUCT,COMMON"|"S"|"1994"|"10"|"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"|"Toilet rooms renovated (new C.T.)"|"1"|"INSTRUCT,COMMON"|"U"|"2009"|"5"|"17000"|"Recommend refinishing floors @ Stage/Tech room"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1994"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1994"|"5"|"15000"|"Recommend brick re-pointing miscellaneous area"|"1"|"METAL"|"S"|"1994"|"20"|"0"||"1"|"MASONRY"|"S"|"1929"|"20"|"0"||"U"|"U"|"0"|"1"|"1994"|"5"|"20000"|"Recommend replacing (5) exterior doors"|"1"|"S"|"2007"|"5"|"10000"|"Recommend replacing south stair railings."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"25"|"0"||"CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"10"|"0"||"1"|"GLASS"|"S"|"1999"|"10"|"0"||"1"|"COPPER"|"S"|"1994"|"45"|"0"||"1"|"IRON"|"S"|"2008"|"45"|"0"|"Kitchen upgrades."|"1"|"NAT_GAS"|"S"|"2001"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"|"Automatic faucets & flush valves"|"0"||"1"|"BOILERSTEA"||"S"|"2005"|"30"|"0"|"HB Smith steam boilers"|"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"1994"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"|"Return fans added to Auditorium/Band (AHU's)"|"1"|"S"|"1994"|"15"|"0"||"1"|"S"|"2009"|"25"|"0"|"Dampers added to Band & Auditorium (AHU's)"|"1"|"S"|"2009"|"5"|"263000"|"Recommend replacing remaining pneumatic controls w/ DDC controls (classroom UV's)"|"1"|"S"|"2001"|"15"|"0"|"Existing FCI 7200 point addressable"|"1"|"S"|"2001"|"15"|"0"|"point addressable devices"|"1"|"S"|"2007"|"2007"|"0"|"Ansul system upgraded for exhaust hood modifications"|"1"|"S"|"1994"|"5"|"5000"|"Recommend replacing exit signs w/ LED type"|"1"|"S"|"2004"|"45"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"Cafeteria acoustic upgraded in 2005"|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"HVAC,FIREALARM,LIGHTING"|"WARMING"||"1"||"GOOD"||"1069000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/8/2010 2:45:49 PM| 161|"HinSDale CSD"|"04140104"|"HINSDALE CENTRAL"|"0001"|"10/05/2010"|"3701 MAIN STREET "|"HINSDALE "|" 14743"|"ANNUAL"|"01/01/2007"|"1935"|"131496"|"3"|"1"|"6"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"465"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"465"|"0"|"0"|||"32"|"24247"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1996"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1971"|"5"|"50,000"|"Replacement of 4 inch cast iron water service."|"1"|"SITESEPT"|"S"|"1999"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"20"|"0"||"1"|"S"|"1972"|"20"|"0"||"0"||||"0"||"1"|"S"|"1990"|"20"|"0"|"Dry Well system."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1990"|"20"|"0"|"Stormwater pump station"|"1"|"ASPHALT"|"S"|"2000"|"5"|"176,100"|"Bus loop & parking areas"|"1"|"CONCRETE"|"S"|"2005"|"15"|"0"||"1"|"S"|"2007"|"10"|"35,000"|"Upgrade to rubberized play surface would provide fall protection."|"1"|"S"|"1997"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"25"|"0"|"1990 work was addition to foundation. No major repairs or reconstruction of original foundation occured. "|"1"|"S"|"1999"|"25"|"0"||"1"|"S"|"1999"|"25"|"0"||"0"|"S"|"1996"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"S"|"2005"|"25"|"0"||"1"|"S"|"1997"|"25"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"1999"|"5"|"52,800"|"Gym light improvements would create energy savings"|"1"|"1"|"S"|"1994"|"5"|"6600"|"Connect bus garage"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"5"|"2500"|"Main office & Conference room"|"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"0"||"0"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2005"|"5"|"26,400"|"Refinishing wood floors in 7 classrooms would lengthen the usable life span of the flooring."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"25"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"25"|"0"||"1"|"MASONRY,METAL"|"S"|"2000"|"25"|"0"|"Liner installed 2000"|"0"|"MASONRY"|"S"|"2000"|"25"|"0"||"S"|"S"|"0"|"1"|"2005"|"10"|"0"||"1"|"S"|"1999"|"5"|"52,800"|"Rennovate rear entrance at Kitchen"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"5"|"7,500"|"Some windows need hardware replacement"|"METONMET,WOODONWOOD"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"5"|"1,118,000"|"Portions of roof at the end of useful life cycle (ballasted epdm)"|"1"|"PLASTIC"|"S"|"1999"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"15"|"0"||"1"|"OIL"|"S"|"2001"|"5"|"13,200"|"water heater in kitchen should be reduced"|"1"|"S"|"1999"|"5"|"17,500"|"Upgrades needed in nurse's station and upstairs urinals"|"1"|"OTHER"|"1"|"BOILERSTEA"||"S"|"1996"|"5"|"726,000"|"Steam to hotwater conversion would create energy savings."|"0"|"S"|"1994"|"10"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"|"Piping in crawl spaces has asbestos insulation"|"1"|"S"|"2005"|"15"|"0"||"0"|"S"|"2001"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"1994"|"1994"|"201,300"|"Kitchen hood would need to be replaced with new kitchen equipment project"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"2000"|"5"|"13,200"|"Connect more circuits to existing generator"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"Band practice room could use soundproofing"|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"FRIDGE"|"FULL"||"1"||"GOOD"|"Could use enlarged health suite and larger technology shop"|"2,568,900"|"S"|"1"|"Clark Patterson Lee"|"130 S. Union Suite 4 Olean NY 14760"|"7163720514"|"tmcelheny@clarkpatterson.com"|"Tom McElheny"|"059176"|"I ACCEPT"|12/8/2010 2:57:04 PM| 162|"BOCES Broome-Tioga"|"03900000"|"Duplicating Center"|"7042"|"09/03/2010"|"555 Conklin Road"|"Binghamton"|" 13903"|"ANNUAL"|"12/01/2010"|"1995"|"18662"|"1"|"0"|"0"|"LSD_DIST"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"|"combination fire and domestic (8") 3/4" domestic."|"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2004"|"30"|"0"||"1"|"S"|"2004"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"0"||"1"|"CONCRETE"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"30"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"20"|"0"||"1"|"METAL"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2004"|"10"|"0"||"METONMET"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"30"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"30"|"0"||"1"|"NAT_GAS,ELECTRIC"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"2004"|"0"|"sprinkler system class 1."|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"1"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"0"|"S"|"1"|"Clark Patterson Lee"|"59 Court Street Binghamton, N.Y. 13901"|"1-800-274-9000"|"rwarholic@clarkpatterson.com"|"John J. Martin, PE"|"057961"|"I ACCEPT"|12/8/2010 2:59:01 PM| 163|"Brewster CSD"|"48060106"|"Brewster High School"|"0004"|"07/16/2010"|"50 Foggintown Rd."|"Brewster,NY"|" 10509"|"ANNUAL"|"05/01/2011"|"1972"|"172,000"|"3"|"9"|"1"|"DISTRICT"|"INSTRUCT"||"1234"|"9,10,11,12"|"0"|"1"|"0"|"1234"|"0"|"0"|||"20"|"15400"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"WELL"|"S"|"2001"|"10"|"360000"|"Water originates at a shared tank located at HH Wells MS that is beyond its life expectancy. Cost indicated is for a dedicated well, tank and treatment for HS on-site"|"1"|"MUN_UTILIT"|"S"|"2005"|"10"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"20"|"0"||"0"||||"0"||"1"|"S"|"2001"|"20"|"1000"|"Cost is for one (1) grate over inlet at small detention basin."|"0"||||"0"||"1"|"ONSITE,OTHER"|"daylight"|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"3"|"351500"|"Cost to repair two small areas and replace back lot by gym"|"1"|"CONCRETE,ASPHALT,OTHER"|"S"|"2001"|"10"|"8500"|"Provide paved path with 30" fence opening for ADA access to track; replace HC curb cut."|"0"||||"0"||"1"|"S"|"2001"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2008"|"15"|"105600"|"Allowances to investigate areas of original wood paneling and replace if not Class C, and to replace larger wireglass units - both necessary to bring building to compliance with current code. Provide white board at classroom 111."|"1"|"S"|"2001"|"7"|"1725"|"Replace ceiling tiles in language office, room 137."|"1"|"U"|"2001"|"10"|"90000"|"Replace balance of original (1972) lockers which are beyond their useful life - approx. 25% of total locker count."|"1"|"S"|"S"|"2008"|"10"|"53400"|"Replace select smoke doors, add electromagnetic hold-opens to select doors, and upgrade to ADA hardware on original classroom doors (1972)."|"1"|"S"|"2001"|"7"|"0"||"1"|"S"|"1972"|"6"|"0"||"1"|"1"|"S"|"2007"|"20"|"21600"|"Add occupancy sensors to bathroom lighting to conform with current NYS energy code."|"1"|"S"|"2007"|"20"|"0"||"1"|"1"|"S"|"2001"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"20"|"0"||"1"|"COMMON"|"S"|"1972"|"20"|"0"||"1"|"COMMON"|"S"|"1972"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"1"|"0"||"S"|"2001"|"15"|"32000"|"Cost to address water infiltration at East upper auditorium wall, and corner chipping near cafeteria delivery area."|"1"|"MASONRY"|"S"|"2001"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"20"|"0"||"1"|"S"|"2001"|"15"|"6400"|"Replace guard rail at retaining wall near stair 4 in front of school and rail at art room exit."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2001"|"3"|"323900"|"Replace balance of original single glazed windows (1972) and restore natural light to gym by cutting-in new clerestory windows on two sides."|"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"7"|"5000"|"Replace one leaking skylight at Guidance (1972). Additionally, sections of 15 year old foam roof on original building will likely need to be replaced within 5-7 years."|"1"|"PLASTIC"|"S"|"2001"|"7"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2001"|"15"|"0"|"Hot water piping and some cold water piping were replaced in 2001."|"1"|"IRON"|"S"|"2001"|"15"|"0"||"1"|"NAT_GAS"|"E"|"2001"|"10"|"6000"|"Cost to add insulation to storage tank."|"1"|"S"|"2001"|"20"|"0"||"0"||"0"|"BOILERWATE"||"S"|"2001"|"15"|"10000"|"Cost to enlarge boiler room ventilation louvers and dampers to solve reported overheating."|"0"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"10"|"0"|"Useful life of pumps will expire in 10 years, balance of system in 30"|"1"|"S"|"2001"|"30"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2001"|"10"|"65000"|"Add strobes in LGI 119 and in non-renovated 1972 classrooms to comply with current SED requirements."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2001"|"10"|"60000"|"Provide additional emergency lighting in interior classrooms adn LGI 119."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"1"|"GOOD"|"Some duct dust accumulation in sections of original (1972) building"|"0"|"1"|"0"|"1"|"1"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"WARMING"|"0"|"1"|"0"|"GOOD"||"1501625"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"rdavidson@kgdarchitects.com"|"Russell A.Davidson, AIA"|"019885"|"I ACCEPT"|12/8/2010 3:16:15 PM| 165|"Nyack UFSD"|"50030403"|"Upper Nyack Elementary"|"0007"|"07/07/2010"|"336 NORTH BROADWAY "|"UPPER NYACK "|" 10960"|"ANNUAL"|"03/01/2011"|"1956"|"47,370"|"2"|"2"|"5"|"DISTRICT"|"INSTRUCT"||"446"|"K,1,2,3,4,5"|"0"|"1"|"0"|"446"|"0"|"0"|||"26"|"20,000"|"ADMIN,ART,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"1,000"|"S"|"1989"|"10"|"0"|"No leak detected. Tested regularly."|"1"|"MUN_UTILIT"|"S"|"1989"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"25"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"1989"|"15"|"$500.00"|"Repair collapsing pavement at south end of west parking lot."|"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1989"|"10"|"$15,000.00"|"Repairs needed to repair lot, path to baseball field, retaining wall, and 50 LF of concrete curb."|"1"|"CONCRETE,ASPHALT"|"S"|"1989"|"10"|"0"|"Work to be done in conjunction with pavement repairs above."|"1"|"S"|"1989"|"15"|"0"||"1"|"S"|"1989"|"15"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1989"|"15"|"$10,000.00"|"Replace old / non-ADA compliant knobs, misc. hardware, NE door and frame, elevator hinges, resource room closer and math classroom jambs."|"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"1"|"S"|"2007"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1990"|"3"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"10"|"0"||"1"|"COMMON"|"S"|"1989"|"15"|"0"||"1"|"COMMON"|"U"|"1989"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1989"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1989"|"20"|"$3,000.00"|"Misc. brick repair, scrape and paint brick lintels."|"1"|"MASONRY"|"S"|"1956"|"20"|"$1,000.00"|"Rain cap needed on chimney."|"0"|||||"0"||"S"|"S"|"1"|"1"|"1989"|"15"|"$19,000.00"|"Replace door/frame at north cafeteria, classroom #1, boiler room, NW vestibule, weatherstrip main doors."|"1"|"S"|"1989"|"10"|"$500.00"|"Level asphalt landings - Priority Project."|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1989"|"15"|"$275,000.00"|"1956 building needs new windows."|"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"2001"|"10"|"$360,000.00"|"1956 gym roof and 1989 addition roof need to be replaced. 1956 eaves must be tested prior to refinishing."|"0"|||||"0"||"1"|"COPPER"|"S"|"1989"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"1989"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"15"|"0"|"Two units were replaced within past 2 years."|"1"|"S"|"1989"|"10"|"$4,000.00"|"Misc. fixtures in 1956 building need replacement / ADA modification."|"0"||"1"|"BOILERWATE,OTHER"|"Unit ventilation"|"S"|"2005"|"20"|"$8,000.00"|"Old, inefficient burners should be replaced."|"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"|"Window AC units, split system in server room."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1989"|"15"|"$4,000.00"|"Replace HW pumps."|"1"|"S"|"1989"|"15"|"$20,000.00"|"Two cafeteria HVAC units are beyond useful life expectancy and create loud ambient noise."|"1"|"S"|"2005"|"20"|"$160,000.00"|"Upgrade 1989 addition controls to digital."|"1"|"S"|"1989"|"10"|"$5,000.00"||"1"|"S"|"1989"|"10"|"0"|"Old detectors are scheduled for replacement."|"1"|"S"|"2005"|"2005"|"$2,000.00"|"Connect Ansul System to F.A."|"1"|"S"|"2001"|"10"|"$6,500.00"|"Recommend additional emergency fixtures, 1956 wing, NS corridor."|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"|"HVAC unit noise in auditorium - consider replacement."|"DAYLIGHT,FL_NOT_Ful,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"$893,500.00"|"S"|"1"|"DCAK-MSA , H2M"|"53 Hudson Avenue Nyack, NY 10960"|"845-353-1300"|"dc@dcak-msa.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/8/2010 3:31:13 PM| 166|"Southern Cayuga CSD"|"05070104"|"Emily Howland Elementary"|"0006"|"08/20/2010"|"2892 Route 34B"|"Aurora"|" 13026"|"ANNUAL"|"10/01/2010"|"1933"|"61,500"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"318"|"Pre-K,K,1,2,3,4"|"0"|"1"|"0"|"318"|"0"|"0"|||"27"|"20,500"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"1"|"0"|"10,000"|"S"|"1991"|"10"|"0"||"1"|"WELL"|"S"|"1972"|"10"|"0"||"1"|"SITESEPT"|"U"|"2000"|"5"|"219,000"|"Recommend replacing 1952 septic field to meet code."|"1"|"S"|"1954"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"5"|"5,000"|"Recommend additional site lighting @ rear parking lot."|"1"|"S"|"2000"|"20"|"0"||"1"|"U"|"2000"|"5"|"35,000"|"Shallow drainage swales at play area. Off site runoff enters property."|"0"|"U"|"2000"|"5"|"44,000"|"East parking area lacks adequate drainage infrastructure."|"1"|"S"|"2000"|"20"|"0"||"1"|"MUNI,OTHER"|"Roadside ditch"|"1"|"S"|"2000"|"20"|"0"|"Property discharges to Rt.34B box culvert."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"5"|"131,000"|"East parking lot requires drainage improvements incorporated with pavement replacement."|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"15"|"0"||"1"|"U"|"2005"|"5"|"175,000"|"Seasonally wet. Some of the play equipment is out of code compliance."|"1"|"U"|"2005"|"5"|"105,000"|"N"|"Drainage improvements/ re-contour grade required for play fields due to seasonal wetness."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1952"|"20"|"0"||"1"|"S"|"1952"|"15"|"0"||"1"|"S"|"2003"|"5"|"95,000"|"Recommend replacing gym divider partition."|"1"|"U"|"1991"|"5"|"158,000"|"Recommend replacing ceilings in most locations (stained/damaged)"|"1"|"U"|"1952"|"5"|"70,000"|"Recommend replacing lockers."|"1"|"U"|"U"|"1952"|"5"|"40,000"|"Recommend replacing gym/classroom doors & door hardware."|"1"|"S"|"1954"|"25"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"1"|"S"|"2000"|"10"|"0"||"1"|"U"|"1995"|"5"|"120,000"|"Add occupancy sensors and energy efficient fluorescent luminaires in corridors and classrooms."|"1"|"1"|"U"|"2008"|"5"|"80,000"|"Recommend replacing PA & Clock Headend."|"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1991"|"15"|"0"||"1"|"COMMON"|"U"|"1954"|"5"|"5,000"|"Recommend replacing ceramic tile @ toilet rooms"|"1"|"INSTRUCT"|"S"|"1954"|"15"|"0"|"on going maintenance @ gym/classrooms."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1952"|"20"|"0"||"MASONRY,STEEL,WOOD"|"0"|"0"||"1"|"0"|"0"|"1"|"1"|"Mortar issues"|"S"|"2005"|"5"|"50,000"|"Recommend brick re-pointing various areas."|"1"|"MASONRY"|"S"|"1991"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"5"|"11,000"|"Recommend replacing misc. doors & door hardware."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1952"|"5"|"400,000"|"Recommend replacing curtain wall system & operable windows."|"METONMET,WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1991"|"10"|"0"||"0"|"PLASTIC"|"U"|"1991"|"20"|"2,000"|"(1) skylight is leaking"|"1"|"GALVANIZED,COPPER"|"U"|"1954"|"5"|"25,000"|"On going maintenance issues. Replace misc. valves & piping and re-insulate."|"1"|"IRON,GALVANIZED,PVC"|"U"|"1993"|"5"|"15,000"|"Recommend replacing risers by gang toilet rooms & laterals in basement."|"1"|"NAT_GAS"|"S"|"2008"|"15"|"0"||"1"|"U"|"2004"|"5"|"50,000"|"Replace remaining original valves/fixtures."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1991"|"15"|"0"||"1"|"S"|"1991"|"15"|"0"||"0"|"S"|"2007"|"10"|"0"|"(2) Computer Labs renovated w/ EXCEL funds."|"1"|"U"|"1970"|"5"|"250,000"|"Recommend replacing (+/- 22) unit vents w/ relief system."|"1"|"U"|"1991"|"5"|"60,000"|"Recommend replacing condensate pumps, misc piping in basement w/ steam specialties."|"1"|"U"|"2000"|"5"|"10,000"|"Recommend relocating dishwasher exhaust away from UV intake on 2nd floor."|"1"|"U"|"1991"|"5"|"100,000"|"Recommend replacing pneumatic controls w/ DDC controls; replace control valves."|"1"|"S"|"2000"|"10"|"0"||"1"|"U"|"2000"|"5"|"15,000"|"Recommend replacing older smoke detectors w/ addressable heads."|"1"|"S"|"1998"|"1998"|"0"|"Existing Ansul system for kitchen hood."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"0"|"0"|"1933 2nd floor is not accessible due to bldg. configuration."|"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"1"|"1"|"0"|"1"|"FAIR"|"0"|"1"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"FAIR"|"Outside air intakes to UV's in rooms 108, 110, & 129 close to grade."|"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"1"|"HVAC,FIREALARM,FRIDGE,LIGHTING"|"FULL"|"1"|"0"|"1"|"FAIR"|"District is considering a future consolidation of facilities."|"2,270,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/8/2010 3:41:41 PM| 167|"BOCES Eastern Suffolk"|"58910000"|"Brookhaven Learning Center West"|"0059"|"10/21/2010"|"351 Martha Avenue"|"Bellport"|"11713"|"ANNUAL"|"05/01/2011"|"1976"|"25100"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"90"|"7,8,9"|"0"|"0"|"0"|"90"|"0"|"0"|||"16"|"14400"|"ADMIN,ART,COMPROOM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,SPECED,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"14"|"0"||"1"|"SITESEPT"|"S"|"1976"|"5"|"0"||"1"|"S"|"2008"|"28"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1976"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2009"|"1"|"20,000"|"Additional repaving needed at North and West sides."|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"9"|"0"||"0"|"E"|"2010"|"15"|"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1976"|"5"|"0"||"1"|"S"|"1976"|"5"|"0"||"1"|"S"|"1992"|"5"|"0"||"1"|"S"|"2008"|"8"|"0"||"1"|"S"|"1976"|"5"|"0"||"1"|"S"|"S"|"2009"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2008"|"8"|"0"||"1"|"S"|"2006"|"6"|"0"||"1"|"1"|"S"|"2008"|"8"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"6"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1976"|"5"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2007"|"7"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"5"|"0"||"0"|"S"|"2009"|"9"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1976"|"5"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1999"|"5"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1992"|"5"|"0"||"1"|"IRON,PVC"|"S"|"1992"|"5"|"0"||"0"|"ELECTRIC"|"S"|"2000"|"5"|"0"||"1"|"S"|"2010"|"5"|"0"|"New sinks in Classrooms."|"1"|"CV"|"1"|"FURNACE"||"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"1976"|"5"|"0"||"1"|"S"|"1976"|"5"|"0"||"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"1996"|"5"|"0"||"0"||||"0"||"1"|"S"|"1999"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"GOOD"||"20,000"|"S"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/8/2010 3:48:15 PM| 169|"BOCES Madison-Oneida"|"25900000"|"Management Services"|"1001"|"08/20/2010"|"SPRING ROAD "|"VERONA "|" 13478"|"ANNUAL"|"08/15/2011"|"1976"|"17675"|"2"|"1"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"|"meetings"|"0"|||"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"SITESEPT"|"S"|"2002"|"16"|"0"|"Sand bed"|"1"|"S"|"1995"|"12"|"0"||"1"|"UTIL,SELF"|"BELOW"|"S"|"2002"|"18"|"0"|"2007 new cogen"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"|"SURFACEH2O"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"9"|"0"||"1"|"CONCRETE"|"S"|"2002"|"12"|"0"|"Small repair needed at the edge of blacktop"|"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1980"|"10"|"0"|"Cracks have stabilized and water penetration is controlled"|"1"|"S"|"1995"|"15"|"0"|"Old basement wall has a crack - crack has stablized no size increase"|"1"|"S"|"1995"|"16"|"0"||"1"|"S"|"1995"|"15"|"0"||"0"||||"0"||"0"|"S"|"S"|"1995"|"10"|"0"||"0"|"S"|"1995"|"9"|"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"12"|"0"||"1"|"S"|"1995"|"10"|"0"|"Most lights are t-12 110 v . need to change to more efficient lighting."|"1"|"1"|"S"|"1995"|"8"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2010"|"9"|"0"|"in the proccess of changing all carpets"|"1"|"COMMON"|"S"|"1995"|"8"|"0"|"most is getting to be in poor shape needs to be replaced"|"1"|"COMMON"|"S"|"1995"|"20"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1980"|"10"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1980"|"10"|"0"|"old basement has a cracked wall- stable -no size increase"|"1"|"MASONRY"|"S"|"1995"|"15"|"0"|"the upper portion could use pointing up."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1995"|"10"|"0"|"Currently upgradeing the access control system with lock down features. "|"1"|"S"|"1995"|"9"|"0"||"1"|"S"|"1"|"1995"|"9"|"0"||"1"|"WOODCLAD"|"S"|"Y"|"1995"|"18"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"0"|"Portions of the roof have been replaced as needed"|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1995"|"17"|"0"||"1"|"NAT_GAS,ELECTRIC"|"S"|"2009"|"12"|"0"||"1"|"S"|"1995"|"10"|"0"|"need to rehab all bathrooms"|"0"||"1"|"BOILERWATE"||"S"|"1995"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"1995"|"11"|"0"|"old units will be replaced insted of repaired due to r-22 "|"0"|"S"|"1995"|"11"|"0"||"0"||||"0"||"1"|"S"|"1995"|"11"|"0"||"0"||||"0"|"manual"|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2007"|"15"|"0"|"Cogen"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"FL_NOT_Ful"|"GOOD"|"need to udate lights"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"WARMING"|"0"|"0"|"1"|"GOOD"||"25000"|"S"|"1"|"William J. Murph CO."|"303 Noyes BLVD, Sherrill ,NY"|"315-363-3682"|"murphy@twcny.rr.com"|"William J.Murphy"|"041799"|"I accept"|12/8/2010 4:00:31 PM| 171|"Brewster CSD"|"48060106"|"John F. Kenndy School"|"0003"|"07/16/2010"|"31 Foggintown Rd."|"Brewster,NY"|" 10509"|"ANNUAL"|"05/01/2011"|"1964"|"64000"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"496"|"K,1,2,3"|"0"|"0"|"0"|"496"|"0"|"0"|||"23"|"19390"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"2"|"250000"|"Add dedicated system to serve JFK ES, Admin bldg and bus barn, with tank and updated disinfection to replace old system in HH Wells MS."|"1"|"MUN_UTILIT"|"S"|"1964"|"10"|"0"||"1"|"S"|"2001"|"31"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1999"|"20"|"0"||"1"|"S"|"1964"|"10"|"0"||"0"||||"0"||"1"|"S"|"1964"|"6"|"10000"|"Clean out several; replace grates as needed; provide grille over 8" inlet; replace crushed pipe."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1985"|"2"|"334710"|"Repave side lot and bus area in front lot."|"1"|"CONCRETE,ASPHALT"|"U"|"1998"|"3"|"74900"|"Replace curb cut, front sidewalk, front curb and utility sidewalk."|"1"|"S"|"1998"|"10"|"16000"|"Repave asphalt play area."|"1"|"S"|"1998"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"10"|"0"||"1"|"S"|"1998"|"7"|"14400"|"Replace large wireglass units at Main Office."|"1"|"S"|"2008"|"10"|"31260"|"Various unconfirmed Class A or B surfaces."|"1"|"S"|"1998"|"3"|"399890"|"Concealed spline ceilings - past useful life. Allowance includes updated lighting and ceilings in both corridor and classrooms."|"0"||||"0"||"1"|"S"|"S"|"2008"|"10"|"10600"|"Wireglass door replacement and hardware upgrades."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1964"|"10"|"0"||"1"|"S"|"2000"|"7"|"200000"|"Allowance to add accessible switches in Auditorium with option for control system."|"1"|"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1998"|"2"|"5700"|"Replace Library carpet."|"1"|"INSTRUCT,COMMON"|"S"|"1965"|"3"|"127740"|"Corridor - replace worn VAT with resilient terrazzo tile."|"1"|"COMMON"|"S"|"1965"|"10"|"0"||"1"|"COMMON"|"S"|"1965"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"10"|"0"||"MASONRY,WOOD"|"0"|"0"||"1"|"0"|"1"|"0"|"1"||"S"|"1970"|"6"|"85000"|"Spalling brick and foundation, failing lintels and soffits."|"1"|"MASONRY"|"S"|"2008"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1964"|"7"|"96000"|"Replace all doors - to address current concerns about wireglass safety."|"1"|"S"|"1964"|"6"|"3000"|"Guard rail replacement at boiler areaway."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1988"|"4"|"788500"|"Typical windows are single glazed and have failing seals; opaque insulating panes - not good for daylighting. Gym clerestory-upgrade rest to laminated safety glass."|"METONMET,WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1964"|"7"|"50000"|"Provide new RPZ backflow preventer."|"1"|"IRON,COPPER"|"S"|"1964"|"5"|"42000"|"Replace rainwater sump pump."|"1"|"ELECTRIC,OTHER"|"S"|"2001"|"6"|"8000"|"One heater not ASME rated and located in student space."|"1"|"S"|"1964"|"10"|"6000"|"Install twelve (12) metering faucets."|"0"||"0"|"BOILERSTEA"||"S"|"2000"|"10"|"0"|"Boilers reportedly refurbished 10 years ago."|"1"|"S"|"2001"|"31"|"0"||"1"|"S"|"2000"|"12"|"0"||"1"|"S"|"2000"|"2"|"690000"|"Replace Gym and Auditorium AHU's and Cafeteria UV's."|"1"|"S"|"1964"|"14"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"11"|"50000"|"Expand to accommodate new equipment."|"1"|"S"|"2000"|"10"|"48000"|"Add strobes to classrooms."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"3"|"35000"|"Additional lights in corridor and testing in assembly spaces."|"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"FAIR"|"Given the age of the building, it has been kept in very good condition."|"3375700"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"rdavidson@kgdarchitects.com"|"Russell A. Davidson, AIA"|"019885"|"I ACCEPT"|12/8/2010 4:28:31 PM| 172|"Penn Yan CSD"|"68060106"|"District Administration Building"|"1029"|"11/12/2010"|"2393 State Route 364"|"Penn Yan"|"14527"|"ANNUAL"|"09/01/2010"|"1960"|"2100"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"250"|"0"|"0"|"S"|"2008"|"20"|"0"|"Propane fuel"|"1"|"MUN_UTILIT"|"S"|"1960"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"30"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"E"|"2008"|"35"|"0"|"200 amp Square D load center is main service panel"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1960"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"20"|"0"||"1"|"ASPHALT"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON,OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"30"|"0"|"Pre-manufactured building (double-wide) set on steel wide flange beams"|"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"25"|"0"||"1"|"S"|"1960"|"25"|"0"||"0"||||"0"||"1"|"1"|"E"|"2008"|"35"|"0"|"Romex wiring acceptable. R-2 construction"|"1"|"E"|"2008"|"25"|"0"||"1"|"1"|"E"|"2008"|"10"|"0"|"Bldg has 6-strand fiber back to DO; 1000 SX connection; Mitel IP Phones"|"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"30"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"30"|"0"||"1"|"METAL"|"S"|"2006"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"||"1"|"S"|"2008"|"30"|"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"NA"|"2008"|"15"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1960"|"20"|"0"||"1"|"PVC"|"S"|"2008"|"40"|"0"||"1"|"ELECTRIC"|"S"|"2008"|"10"|"0"||"1"|"E"|"2008"|"40"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"30"|"0"|"Propane fuel"|"1"|"S"|"2008"|"15"|"0"|"R-22 refrigerant, outdoor ACCU"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2008"|"20"|"0"|"Flexible ductwork @ attic from furnace"|"1"|"S"|"2008"|"15"|"0"|"Single station T-stats, self-contained in electric baseboard"|"1"|"S"|"2008"|"10"|"0"|"120v hard-wired smoke detectors"|"1"|"S"|"2008"|"10"|"0"|"120v hard-wired smoke detectors"|"0"||||"0"||"1"|"S"|"2008"|"10"|"0"|"LED exit signs"|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"0"|"S"|"1"|"King + King Architects LLP"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/8/2010 5:13:25 PM| 173|"Brewster CSD"|"48060106"|"C.V.Starr Intermediate School"|"0009"|"07/16/2010"|"20 Farm to Market Rd."|"Brewster,NY"|" 10509"|"ANNUAL"|"05/01/2011"|"1996"|"56986"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"496"|"4,5"|"0"|"0"|"0"|"496"|"0"|"0"|||"24"|"20000"|"ADMIN,ART,CAFE,COMPROOM,GYM,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"2"|"21000"|"S"|"2004"|"7"|"0"||"1"|"WELL"|"S"|"1997"|"3"|"360000"|"Existing central storage tank is past its useful life (1957). Cost is to provide dedicated storage tank and updated treatment system to serve CV Starr IS and HH Wells MS."|"1"|"MUN_UTILIT"|"E"|"1997"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"7"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1997"|"5"|"39300"|"Cost for repairs to select areas."|"1"|"U"|"1997"|"7"|"52150"|"Re-surface uneven basketball court area."|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"10"|"48000"|"Cost to replace wireglass sidelights to bring building into conformance with current SED standards."|"1"|"S"|"2007"|"15"|"0"||"0"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"15"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"1"|"S"|"1997"|"17"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"1"|"S"|"1997"|"13"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"6"|"0"||"1"|"INSTRUCT"|"S"|"1997"|"10"|"0"||"1"|"COMMON"|"S"|"1997"|"20"|"0"||"1"|"COMMON"|"S"|"1997"|"30"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"2010"|"20"|"0"||"1"|"MASONRY"|"S"|"1997"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1997"|"7"|"0"||"1"|"S"|"2010"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"15"|"0"||"METONMET"|"BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"5"|"50490"|"Allow $5,000 to $10,000 in operational budget for repairs over next 2-3 years; replace by 5"|"1"|"GLASS"|"S"|"2001"|"5"|"0"||"1"|"COPPER"|"S"|"1997"|"38"|"0"||"1"|"IRON,COPPER"|"S"|"1997"|"38"|"0"||"1"|"ELECTRIC"|"S"|"1997"|"6"|"0"|"Heater located in boiler room."|"1"|"S"|"1997"|"38"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1997"|"18"|"0"||"1"|"E"|"2004"|"19"|"0"|"15,000 gallon oil tank added"|"1"|"S"|"1997"|"8"|"0"|"Serving Library and Admin area."|"1"|"S"|"1997"|"13"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"28"|"0"||"1"|"S"|"1997"|"13"|"0"|"Andover DDC controls"|"1"|"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"1997"|"0"||"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"2006"|"7"|"0"|"Central battery system."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"GOOD"||"549940"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"rdavidson@kgdarchitects.com"|"Russell A. Davidson, AIA"|"019885"|"I ACCEPT"|12/8/2010 5:19:51 PM| 174|"Nyack UFSD"|"50030403"|"Valley Cottage Elementary"|"0001"|"07/06/2010"|"26 LAKE ROAD "|"VALLEY COTTAGE "|" 10989"|"ANNUAL"|"03/01/2011"|"1927"|"54,000"|"2"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"475"|"K,1,2,3,4,5"|"0"|"1"|"1"|"475"|"0"|"0"|||"21"|"16,800"|"ADMIN,ART,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"3,000"|"S"|"1986"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"5"|"$50,000.00"||"1"|"MUN_UTILIT"|"S"|"1989"|"15"|"0"||"1"|"S"|"1989"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"SURFACEH2O"||"0"|"S"|"1989"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1989"|"10"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"1989"|"10"|"0"|"N"||"RECONCRETE"|"1"|"0"|"1"|"1"|"0"|"0"|"S"|"1989"|"30"|"$80,000.00"|"Cracking and some deterioration at exterior stairs to lower level of 1027 wing. Water proofing needed at approx. 60% of 1927 lower level walls."|"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1989"|"10"|"$12,000.00"|"Approx. 40 original door knobs in fair condition and should be replaced; non ADA compliant."|"1"|"S"|"1989"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"1"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"15"|"0"||"1"|"COMMON"|"S"|"1989"|"20"|"0"||"0"|"COMMON"|"S"|"1954"|"15"|"0"|"Stage floor."|"SLABGRADE,CONCRMETAL,WOODTRUSS,OTHER"|"DOX Plank"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1989"|"25"|"0"||"MASONRY"|"0"|"1"|"Some cracks in CMU."|"1"|"0"|"1"|"0"|"1"||"S"|"1989"|"25"|"$8,000.00"|"Lintels rusting, misc. minor mortar cracking, masonry needs repointing and caulking at misc. locations."|"1"|"MASONRY"|"S"|"1954"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1989"|"10"|"$24,000.00"|"Some doors on original 1927 wing and 1954 addition are deteriorated and need to be repaired or replaced."|"1"|"S"|"1989"|"20"|"$35,000.00"|"Repairs needed to deterioration at some stairs and railings."|"0"|||||"0"||"1"|"ALUMINUM,VINYL"|"S"|"Y"|"1989"|"15"|"$180,000.00"|"Original single pane steel windows in 1927 and 1954 wings should be replaced to reduce air infiltration and energy loss."|"METONMET,WOODONWOOD"|"BUILTUP,ASPHALT,FORMMETAL"|"0"|"0"|"1"|"0"|"0"||"0"|"0"|"1"|"0"|"1"|"0"|"0"|"0"|"Exposed wood eaves, and soffits on 1954 addition, rusting outriggers and ladder."|"S"|"2009"|"20"|"$30,000.00"|"Ballast missing on built up roofing, alligatoring cracks, paint roof access ladder, paint or wrap fascias all old wings, rotted cafeteria roof plank to be repaired / replaced."|"0"|||||"0"||"1"|"IRON,COPPER,PVC"|"S"|"1989"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1989"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1997"|"10"|"$500.00"|"Repairs required to move insulation away from flue."|"1"|"S"|"1989"|"5"|"$12,000.00"|"Replacement of old sinks and drinking fountains in 1927 and 1954 wings recommended."|"0"||"1"|"BOILERWATE,OTHER"|"Unit ventilation"|"S"|"1990"|"10"|"$18,000.00"|"Replace boiler pumps."|"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"1989"|"5"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"5"|"$24,000.00"|"Replace circulator pumps ans 1/2" line to gym, approx. 320 LF."|"1"|"S"|"1989"|"5"|"0"|"Consider replacement of loud cafeteria and gymnasium units."|"1"|"S"|"1989"|"15"|"$160,000.00"|"Pneumatic controls have not been replaced in 1989 addition to tie into the energy management system."|"1"|"S"|"1989"|"5"|"0"|"Tie-in to 44 Control completed in 2005. Consider upgrade to addressable system."|"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"1989"|"$2,000.00"|"Kitchen hoo. Tie-in to fire alarm system needed."|"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"FAIR"|"HVAC noise in auditorium and gym very loud - consider replacement."|"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"1"|"OTHER"|"PTA storage room, 1927 wing lower level."|"0"|"1"|"4,000"|"Repair 1927 east wing hallway plaster / water stains."|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$639,500.00"|"S"|"1"|"DCAK-MSA, H2M"|"53 Hudson Ave. Nyack, NY 10960"|"845-353-1300"|"dc@dcak-msa.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/8/2010 5:25:47 PM| 175|"North Colonie CSD"|"01062306"|"Maintenance Building"|"3014"|"10/08/2010"|"785 Watervliet Shaker Road"|"Latham"|"12110"|"ANNUAL"|"01/01/2011"|"1953"|"9470"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Maintenance"|"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"10"|"0"|"Original"|"1"|"SITESEPT"|"S"|"1997"|"5"|"40,000"|"Tie into sewer, remove septic"|"1"|"S"|"1997"|"10"|"8,000"|"Regulator replaced, upgrade service."|"1"|"UTIL"|"ABOVE"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"S"|"1953"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"|"SURFACEH2O"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1989"|"5"|"75,000"|"Pave/restripe."|"1"|"ASPHALT"|"S"|"1989"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"1"|"1"|"0"|"0"|"S"|"1953"|"10"|"0"||"1"|"S"|"1989"|"15"|"0"||"1"|"S"|"1989"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"1989"|"15"|"0"||"1"|"S"|"S"|"2009"|"15"|"0"||"1"|"S"|"1953"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"15"|"0"||"1"|"COMMON"|"S"|"1988"|"15"|"0"||"1"|"COMMON"|"S"|"1953"|"10"|"0"||"1"|"COMMON"|"S"|"1953"|"10"|"0"||"SLABGRADE,OTHER"|"Metal grate"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"1"|"S"|"1953"|"10"|"0"||"STEEL,OTHER"|"0"|"1"||"1"|"0"|"0"|"1"|"1"||"S"|"1953"|"5"|"45,000"|"Replace original metal siding."|"1"|"METAL"|"S"|"1989"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1989"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"|"Wood steps to carpentry ok."|"0"|||||"0"||"1"|"ALUMINUM,STEEL,VINYL"|"U"|"NA"|"1953"|"5"|"15,000"|"Replace garage windows."|"METONMET,WOODONWOOD"|"ASPHALT,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"1"|"1"|"1"|"0"|"1"|"0"|"0"|"0"||"S"|"1953"|"5"|"75,000"|"Reroof garage."|"1"|"PLASTIC"|"S"|"1953"|"5"|"0"|"Refer to roofing above."|"1"|"COPPER"|"S"|"1988"|"10"|"0"||"1"|"COPPER"|"S"|"1997"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1997"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1997"|"5"|"15,000"|"Gas horizontal furnace heat office,radiant for garage. Replace carpentry boiler."|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"|"1989 office heat pump furnace."|"1"|"S"|"2010"|"15"|"0"|"Carpentry E.F. replaced 2010."|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"|"Localized."|"1"|"S"|"1997"|"10"|"0"|"Monitored master alarm."|"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"|"0"|"25,000"|"Accessible parking, ramps, toilets."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"FAIR"|"Limited capacity."|"273,000"|"S"|"1"|"CSArch"|"40 Beaver St., Albany, NY 12207"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I accept"|12/9/2010 8:28:28 AM| 176|"Brewster CSD"|"48060106"|"Garden Street School"|"0002"|"07/23/2010"|"20 Garden Street"|"Brewster,NY"|" 10509"|"ANNUAL"|"05/01/2011"|"1925"|"51000"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"399"|"K,1,2,3"|"0"|"0"|"1"|"399"|"0"|"0"|||"25"|"20000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"6000"|"S"|"2001"|"16"|"0"||"1"|"MUN_UTILIT"|"S"|"1925"|"6"|"0"||"1"|"MUN_UTILIT"|"S"|"1925"|"6"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2002"|"30"|"0"||"1"|"S"|"1924"|"7"|"0"||"0"||||"0"||"1"|"S"|"1924"|"7"|"3000"|"Bring drain inlet along driveway up to grade"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"10"|"13500"|"Cracked pavement at garden area; repair two (2) stone walls."|"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"10"|"18000"|"Sidewalk to playground, steps from top driveway."|"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"1990"|"7"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1925"|"20"|"0"||"1"|"S"|"1924"|"7"|"0"||"1"|"S"|"2001"|"5"|"60200"|"Replace windows in corridor walls, wood paneling, glass door cabinets."|"1"|"S"|"2001"|"7"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"7"|"36565"|"Upgrades for safety glazing and ADA levers in specific areas."|"1"|"S"|"1990"|"10"|"232100"|"Allowance for code upgrades, including enclosure of open stairs."|"0"||||"0"||"1"|"1"|"U"|"2007"|"0"|"30000"|"Replace distribution panel in basement."|"1"|"S"|"2007"|"2"|"36000"|"Replace controls and stage lighting; upgrade lighting in classroom 308."|"1"|"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"7"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"7"|"312100"|"Replace VAT in rooms 200 & 316; allowance to replace cracked sections elsewhere."|"1"|"COMMON"|"S"|"1925"|"10"|"0"||"1"|"COMMON"|"S"|"1925"|"10"|"0"||"SLABGRADE,OTHER"|"Concrete slab & beams"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1925"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"1"|"0"|"1"||"S"|"1925"|"4"|"72000"|"Crack & brick repair in several areas; re-pointing 2,500 sf over 5 years."|"1"|"MASONRY"|"S"|"1990"|"7"|"0"||"1"|"MASONRY"|"S"|"1925"|"7"|"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"||"1"|"S"|"2008"|"8"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1981"|"7"|"744800"|"Replace older single pane windows and opaque panels - balances fail frequently."|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"5"|"570240"|"Out of warranty but not leaking - replace within 5 years."|"0"|||||"0"||"1"|"IRON,GALVANIZED,COPPER"|"U"|"1925"|"3"|"207400"|"Replace outdated distribution piping and add RPZ backflow preventer."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1925"|"6"|"0"||"1"|"ELECTRIC,OTHER"|"U"|"2004"|"0"|"25000"|"Replace indirect steam domestic hot water heater."|"1"|"S"|"1925"|"6"|"8600"|"Provide metering lavatory faucets and replace custodial faucet with vacuum breaker type."|"0"||"1"|"BOILERSTEA"||"E"|"2005"|"25"|"0"||"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"U"|"2008"|"0"|"4168000"|"Provide mechanical ventilation for classrooms (includes abatement); replace exhaust fans; provide mechanical ventilation to gymnasium."|"1"|"U"|"1925"|"0"|"570000"|"Replace heating distribution piping; address under-heating of room 107; replace radiator conrol valves; add split system to computer lab to address over-heating."|"0"||||"0"||"1"|"U"|"1925"|"0"|"80000"|"Replace pneumatic controls with DDC system."|"1"|"S"|"2008"|"10"|"36000"|"Add strobes to certain classrooms."|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"2008"|"0"||"1"|"S"|"2002"|"7"|"0"||"0"|"S"|"2002"|"7"|"0"||"1"|"0"|"535000"|"Add 3-stop elevator plus two ramps; ADA toilet in Nurse's office, ADA girls bathroom - #327."|"FAIR"||"GOOD"||"0"|"1"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"0"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"FAIR"||"7760505"|"U"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"rdavidson@kgdarchitects.com"|"Russell A. Davidson, AIA"|"019885"|"I ACCEPT"|12/9/2010 8:38:59 AM| 177|"Brewster CSD"|"48060106"|"Bus Garage"|"5006"|"07/16/2010"|"40 Farm to Market Rd"|"Brewster,NY"|" 10509"|"ANNUAL"|"10/21/2011"|"1971"|"8000"|"1"|"2"|"0"|"DISTRICT"|"OTHER"|"Bus Garage & Transportation Facility"|"0"|"OTHER"|"0"|"0"|"0"||||||"0"|"0"|"OTHER"|"Bus maintenance office"|"1"|"0"|"0"|"3"|"11500"|"S"|"1997"|"2"|"0"||"1"|"WELL"|"S"|"1971"|"6"|"0"|"System originates from HH Wells MS storage tank."|"1"|"MUN_UTILIT"|"S"|"1971"|"6"|"0"||"1"|"S"|"2001"|"16"|"0"|"Buried propane tank."|"1"|"UTIL"|"BELOW"|"S"|"1985"|"25"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2001"|"1"|"211500"|"Cost to replace front lot, resurface side lot and repair one sunken area."|"1"|"CONCRETE"|"S"|"1971"|"6"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"10"|"0"||"1"|"S"|"1971"|"10"|"0"||"1"|"S"|"1971"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1971"|"4"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"0"|"S"|"2007"|"1"|"103000"|"Replace main switchboard, add panelboards for better coverage."|"1"|"U"|"1985"|"0"|"25000"|"Need more coverage in repair bays."|"1"|"1"|"S"|"1990"|"5"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1971"|"10"|"0"||"1"|"COMMON"|"S"|"1971"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"10"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"10"|"0"||"1"|"METAL"|"S"|"1971"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1971"|"10"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,OTHER"|"S"|"NA"|"1971"|"2"|"88000"|"Replace failing translucent clerestories with Kalwall style insulated system."|"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"10000"|"Allowance to add RPZ backflow preventer."|"1"|"IRON,COPPER"|"S"|"1971"|"6"|"0"||"1"|"ELECTRIC"|"S"|"2001"|"6"|"0"||"1"|"S"|"2001"|"31"|"0"||"1"|"CV"|"1"|"OTHER"|"Gas overhead radiators"|"S"|"2008"|"10"|"5000"|"Remove abandoned electric heaters."|"1"|"S"|"2001"|"16"|"0"|"Buried propane tank."|"1"|"S"|"2001"|"6"|"0"|"Dx condensing unit"|"1"|"S"|"1971"|"0"|"35000"|"Replace garage ventilation fans."|"0"||||"0"||"1"|"S"|"1990"|"6"|"0"||"1"|"S"|"2001"|"6"|"30000"|"Provide diesel fume/carbon monoxide alarm system."|"1"|"S"|"2000"|"5"|"10000"|"Add additional components for coverage."|"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"S"|"1985"|"0"|"15000"|"Additional lights and exit signs required."|"1"|"S"|"2009"|"10"|"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"POOR"||"NA"|"POOR"|"Need more light on task."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"1"|"1"|"0"|"1"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,LIGHTING"||"0"|"1"|"0"|"FAIR"||"532500"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"rdavidson@kgdarchitects.com"|"Russell A. Davidson, AIA"|"019885"|"I ACCEPT"|12/9/2010 9:21:50 AM| 178|"North Colonie CSD"|"01062306"|"Boght Hills Elementary"|"0007"|"06/09/2010"|"38 Dunsbach-Ferry Road"|"Cohoes"|"12047"|"ANNUAL"|"01/01/2011"|"1955"|"59,900"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"439"|"K,1,2,3,4,5,6"|"0"|"1"|"0"|"439"|"0"|"0"|||"26"|"22,280"|"ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"|"Water service replaced in 2005."|"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"S"|"1955"|"5"|"11,000"|"Gas service is original trident-type."|"1"|"UTIL"|"BELOW"|"S"|"2002"|"20"|"0"|"Transformer changed from vault to PAD in 2002."|"1"|"S"|"2002"|"15"|"0"||"1"|"U"|"2002"|"10"|"0"|"Drains to daylight, see athletic fields."|"1"|"S"|"2002"|"20"|"0"|"Replace drain fabric regularly."|"1"|"S"|"2002"|"15"|"0"||"1"|"OTHER"|"drain to adjacent ditch"|"0"|"S"|"1955"|"10"|"0"|"Colvert to adjacent property ditch."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"15"|"0"|"Asphalt sealer should be applied."|"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"15"|"0"|"Front entry walk is in fair condition."|"1"|"S"|"2002"|"20"|"0"|"1996, 2002 were replaced."|"1"|"U"|"1955"|"10"|"500,000"|"N"|"Drainage issues at main field."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"|"Concrete foundations are original per vintage."|"1"|"S"|"2002"|"20"|"0"|"No structural issues on bearing walls."|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"|"374 total count."|"1"|"S"|"S"|"2002"|"15"|"0"|"Original 1955 doors are not fire rated."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"25,000"|"Plan to replace gym lights with high efficiency."|"1"|"1"|"S"|"2003"|"15"|"0"|"PA is original vintage, upgraded parts, telephone replaced in 1997."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2002"|"10"|"0"|"2002 carpet continues to bubble."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"20,500"|"ACM at 1955 wing, joints at 1991."|"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"COMMON"|"S"|"1955"|"15"|"0"|"Gym and stage."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"|"Original floor slabs in each vintage."|"OTHER"|"0"|"0"||"1"|"1"|"1"|"1"|"1"||"S"|"1991"|"5"|"65,000"|"1991 Composite panels should be replaced."|"1"|"MASONRY"|"S"|"1991"|"10"|"0"|"1991 masonry chimney is fine, 1955 coping needs sealing."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"20"|"0"|"Consider replacing HM doors at 1991 with FRP."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"10"|"0"|"Discolored kalwall - warranty?"|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"0"|"1991 roof is stone ballast and has never benn replace."|"1"|"PLASTIC"|"S"|"2002"|"10"|"0"||"1"|"COPPER"|"S"|"2003"|"10"|"0"||"1"|"IRON,GALVANIZED"|"S"|"2003"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"5"|"30,000"|"Fixtures at 1955 wing aree old/non ADA."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"10"|"35,000"|"Remove 1991 boilers, tie-in to 2003 boilers."|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"|"Consider central A/C to library."|"1"|"S"|"2003"|"5"|"295,000"|"1955 vintage UVs to be replaced in 2010."|"1"|"S"|"2003"|"15"|"0"|"Heating pumps replaced in 2003."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"|"DDC controls replacing pneumatic 2010."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"15,000"|"Emergency light coverage may not satisfy current code."|"0"||||"0"||"1"|"0"|"35,000"|"Auto door opener"|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"|"1991 and 1955 wings do not have occupancy controls."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"GOOD"||"1,544,000"|"S"|"1"|"CSArch"|"40 Beaver Street, Albany, NY 12207"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I accept"|12/9/2010 9:35:07 AM| 180|"Nyack UFSD"|"50030403"|"Middle School"|"0004"|"05/18/2010"|"98 SOUTH HIGHLAND AVE "|"NYACK "|" 10960"|"ANNUAL"|"03/01/2011"|"1957"|"160,620"|"3"|"2"|"5"|"DISTRICT"|"INSTRUCT"||"652"|"6,7,8"|"0"|"1"|"0"|"652"|"0"|"0"|||"46"|"36,800"|"ADMIN,ART,AV,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY,MUSIC,SCIENCELAB,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"2006"|"20"|"0"|"Steel tank"|"1"|"MUN_UTILIT"|"S"|"2005"|"25"|"$3,000.00"|"Repair leaks in 3" service feed in meter pit."|"1"|"MUN_UTILIT"|"S"|"1992"|"15"|"0"|"200 gallon chemical storage tank."|"1"|"S"|"1992"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"2005"|"25"|"$1,200.00"|"Cover needed on lower driveway."|"0"||||"0"||"1"|"MUNI,SURFACEH2O"||"1"|"S"|"1992"|"0"|"$35,000.00"|"Additional Rip Rap and containment structures."|"1"|"S"|"1992"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"10"|"$57,000.00"|"Curbing needed on exit drive. Re-pave Field House drive."|"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"10"|"$2,000.00"|"Main entry cirb is spalling, misc. repairs needed."|"0"||||"0"||"1"|"S"|"1992"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"15"|"$3,000.00"|"Replace misc. tiles; patch plaster in Boiler Room."|"1"|"S"|"1992"|"10"|"0"|"Lockers in 1957 wing are in fair condition."|"1"|"S"|"S"|"1992"|"10"|"$6,000.00"|"Replace selected 1957 hardware, several stair and fire doors don't latch, remove holds at fire doors, stair B and cafeteria bays need closers."|"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1992"|"15"|"$35,000.00"|"Tiles in 1957 wing are in fair condition."|"1"|"COMMON"|"S"|"1992"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1992"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1992"|"20"|"0"|"Cracking at southwest corner of gym and door openings must be reviewed. Remove caulk at flashing."|"1"|"MASONRY"|"S"|"1992"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"10"|"$4,000.00"|"South vestibule door / hardware sticks. Misc. weatherstripping/bent frame at main vestibule needs repair."|"1"|"S"|"1992"|"10"|"$15,000.00"|"Replace northeast wood steps."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1991"|"15"|"0"||"METONMET,WOODONMET,OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"S"|"1992"|"5"|"$750,000.00"|"Regular leaks occur; past repairs are poor, protective fabric is missing."|"1"|"OTHER"|"S"|"1991"|"20"|"0"|"Plastic and glass skylights present."|"1"|"COPPER"|"S"|"1992"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1992"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2006"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1992"|"5"|"$400,000.00"|"Equip. functional. Inspect/repair for leaks in boiler sections. Jacketing/insulation removed for inspection of joints between sections. Pressure test to be performed. Capacity of combustion air fans to be verified to ensure Mechanical Code conformance."|"0"||||"0"||"1"|"S"|"1992"|"7"|"0"|"Split systems serving limited areas."|"1"|"S"|"2005"|"20"|"$40,000.00"|"Sawdust exhaust system for shop is failing."|"1"|"S"|"1992"|"5"|"0"|"Cost included in item #75 above. Pump flanges leak, pumps near end of useful life, valve replacement needed."|"1"|"S"|"1992"|"20"|"$20,000.00"|"Replace remaining fans in 1957 building."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"|"Additional Coverage recommended."|"1"|"S"|"1992"|"1992"|"0"|"Ansul system."|"1"|"S"|"1991"|"5"|"$2,000.00"|"Additional signs recommended at 1st floor corridor at Sair B, Stair B second floor, and boys locker room - south."|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$1,373,200.00"|"S"|"1"|"DCAK, H2M"|"53 Hudson Avenue Nyack, Ny 10960"|"845-353-1300"|"dc@dcak-msa.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/9/2010 10:24:44 AM| 181|"BOCES Madison-Oneida"|"25900000"|"Support Services"|"1006"|"08/16/2010"|"SPRING ROAD "|"VERONA "|" 13478"|"ANNUAL"|"08/15/2011"|"1978"|"13321"|"1"|"1"|"0"|"DISTRICT"|"OTHER"|"printing and storage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"18"|"0"||"1"|"SITESEPT"|"S"|"2002"|"16"|"0"||"1"|"S"|"1994"|"16"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1980"|"6"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"8"|"0"||"1"|"CONCRETE"|"S"|"2002"|"8"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1978"|"10"|"0"||"1"|"S"|"1990"|"8"|"0"||"1"|"S"|"1990"|"6"|"0"||"1"|"S"|"1999"|"10"|"0"|"idividual replacments as needed"|"0"||||"0"||"1"|"S"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"11"|"0"||"1"|"S"|"1995"|"7"|"0"||"1"|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"5"|"6000"||"1"|"INSTRUCT"|"S"|"2002"|"16"|"0"||"1"|"COMMON"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1978"|"10"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"20"|"0"||"0"|"METAL"|"S"|"2000"|"11"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2003"|"10"|"0"||"1"|"S"|"2000"|"5"|"0"||"0"|||||"0"||"0"|"WOODCLAD"|"S"|"NA"|"2003"|"20"|"0"||"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1990"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"10"|"0"||"1"|"ELECTRIC"|"S"|"2009"|"12"|"0"||"1"|"S"|"1994"|"4"|"0"|"Fixtures are satisfactory but in fair condition"|"0"||"1"|"BOILERWATE"|"cogen"|"S"|"1994"|"6"|"0"|"need to rehab the heating system"|"1"|"S"|"1994"|"6"|"0"||"1"|"S"|"2003"|"14"|"0"|"many split units"|"1"|"S"|"2003"|"14"|"0"||"1"|"S"|"2003"|"16"|"0"||"0"||||"0"||"0"||||"0"|"manual"|"1"|"S"|"1985"|"8"|"0"||"1"|"S"|"1985"|"6"|"0"||"0"||||"0"||"1"|"S"|"1990"|"6"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"FL_NOT_Ful"|"GOOD"|"need more work"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"0"|"0"|"GOOD"||"20000"|"S"|"1"|"William J. Murphy CO."|"303 Noyes BLVD Sherrill NY 13461"|"315-363-3682"|"murphy@twcny.rr.com"|"William J. Murphy"|"041799"|"I accept"|12/9/2010 10:54:26 AM| 183|"Commack USFD"|"58041003"|"Burr Lane Maintenance Storage"|"2005"|"02/16/2010"|"200 Burr Road"|"Commack, NY"|"11725"|"ANNUAL"|"05/01/2011"|"1978"|"1960"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Maintenance Storage"|"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"OTHER"|"Maintenance Storage"|"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1978"|"32"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1978"|"10"|"0"||"1"|"ASPHALT"|"S"|"1978"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1978"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1978"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"||"0"|"0"|"S"|||"0"||"1"|"S"|"1978"|"5"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1978"|"32"|"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1978"|"25"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1978"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1978"|"10"|"0"||"0"|"S"|"1978"|"25"|"0"||"0"|||||"0"||"0"|"OTHER"|"S"|"NA"|"1978"|"15"|"0"||"WOODONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1978"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"1"|"OTHER"||"S"|"1978"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"|"S"|||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"0"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"0"|"S"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/9/2010 12:50:00 PM| 184|"Southern Cayuga CSD"|"05070104"|"Jr./Sr. High School"|"0007"|"08/20/2010"|"2384 Route 34B"|"Poplar Ridge"|" 13139"|"ANNUAL"|"10/01/2010"|"1967"|"178000"|"1"|"5"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"489"|"5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"489"|"0"|"0"|||"38"|"30659"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP,OTHER"|"Agriculture Shops"|"1"|"0"|"0"|"2"|"10000"|"S"|"1991"|"15"|"0"||"1"|"WELL"|"S"|"1993"|"10"|"32000"|"Separate well system for athletic field irrigation. Due to low yield wells, supplement irrigation cistern with water supply from HS."|"1"|"SITESEPT"|"U"|"1999"|"5"|"131000"|"Recommend replacing HS pump chamber, pumps, controls; replace MS pumps & add vent system"|"1"|"S"|"1993"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1995"|"15"|"18000"|"Recommend replacing & supplementing outdoor egress/security lighting."|"1"|"U"|"2000"|"5"|"9000"|"Recommend flushing drainage piping @ MS (silted)"|"1"|"U"|"1999"|"5"|"70000"|"Ditches silted in & over vegetated - dredge. Cut-off swale required @ tennis courts to collect off-site water from entering school property. Channel Rt. 34B road ditch with concrete gutter. Correct courtyard drainage (odor complaints)"|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"0"|"ONSITE,OTHER"|"Stream & roadside ditch"|"1"|"U"|"2000"|"5"|"10000"|"Drainage ditch between detention facility and road culvert is silted in and over vegetated requiring dredging."|"0"||||"0"||"0"||||"0"||"1"|"U"|"2000"|"5"|"123000"|"Detention facility is silted in and over vegetated requiring dredging."|"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"5"|"263000"|"MS parking lot deteriorating, requiring select cutting, patching and sealing."|"1"|"CONCRETE,ASPHALT"|"U"|"2000"|"5"|"61000"|"Concrete curbs at MS in poor condition, replace; Recommend providing sidewalks to athletic fields."|"1"|"U"|"1997"|"5"|"105000"|"Upgrades are recommended @ M.S. to replace outdated equipment. Inspections made annually by BOCES."|"1"|"U"|"2000"|"5"|"210000"|"N"|"Fields seasonally wet, drainage improvements required at 2 softball and 2 baseball. Additional clay infield material at baseball and softball required to correct surface drainage. "|"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"5"|"10000"|"Additional expansion/control joints/caulk @ M.S."|"1"|"S"|"1991"|"15"|"0"|"Costs associated w/ M.S. cracks is indicated on question #56."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2007"|"5"|"60000"|"Portion of corridor ceilings replaced w/ EXCEL funds; replace original ceilings (corridor/auditorium)"|"1"|"S"|"2000"|"10"|"0"|"On-going maintenance"|"1"|"S"|"S"|"1991"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"20"|"0"|"Power & data upgrades w/ EXCEL funds"|"1"|"U"|"2007"|"5"|"96000"|"Recommend upgrading lights @ various classrooms & gym."|"1"|"1"|"E"|"2007"|"15"|"0"|"New VOIP system w/ EXCEL funds."|"1"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"2000"|"5"|"50000"|"Recommend replacing library & auditorium carpet"|"1"|"INSTRUCT"|"U"|"1967"|"5"|"86000"|"Abate VAT & replace w/ vinyl composition tiles (VCT) in 4 classrooms"|"1"|"INSTRUCT,COMMON"|"S"|"1967"|"5"|"5000"|"Recommend repair/replace terrazzo @ main entry (assume 120sf)."|"1"|"INSTRUCT"|"U"|"1991"|"5"|"26000"|"Recommend replacing stage floor."|"SLABGRADE"||"0"|"0"|"1"|"0"|"0"||"1"|"0"|"1"|"S"|"1996"|"5"|"5000"|"Recommend cleaning/priming/painting corroded structural members @ pool filter room."|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1996"|"5"|"5000"|"Minor caulking & masonry re-pointing is recommended @ miscellaneous areas."|"1"|"METAL"|"S"|"2007"|"25"|"0"|"Replaced with EXCEL funds"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"5"|"450000"|"Recommend replacing misc doors (Qty. 8) @ (2) 3'-0"; (Qty. 2) @ 3'-0""|"1"|"S"|"2004"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"15"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"5"|"5000"|"Recommend replacing skylights @ M.S. Gym. MS is in good condition but reaching the end of its expected useful life."|"1"|"PLASTIC"|"U"|"1992"|"5"|"5000"|"MS Gym skylights leak"|"1"|"COPPER"|"U"|"2004"|"5"|"79000"|"Recommend adding re-circ loop to D.O.; replace (2) 500 gal pressure tanks/controls."|"1"|"IRON,COPPER"|"S"|"2003"|"25"|"0"|"Clarification: Sanitary lift pumps are NOT on generator back-up power."|"1"|"NAT_GAS"|"E"|"2007"|"20"|"0"|"New unit w/ EXCEL funds "|"1"|"U"|"2002"|"5"|"105000"|"Replace remaining 1967 fixtures in faculty TR 206/206a & TR 515/518."|"0"||"1"|"BOILERWATE"||"E"|"2007"|"30"|"0"|"New boilers/pumps/controls w/ EXCEL funds"|"1"|"E"|"2007"|"30"|"0"|"New fuel oil pumps & piping w/ EXCEL funds."|"1"|"U"|"2007"|"5"|"80000"|"Recommend replacing auditorium & main office equipment"|"1"|"U"|"1995"|"5"|"613000"|"Recommend replacing auditorium & gym unit & increase ventilation"|"1"|"E"|"2007"|"30"|"0"|"New piping & pumps in boiler room w/ EXCEL funds"|"1"|"S"|"2000"|"20"|"0"|"Pool unit replaced in 2000."|"1"|"E"|"2007"|"15"|"0"|"Expanded DDC controls w/ EXCEL funds to complete MS/HS building."|"1"|"S"|"2000"|"15"|"0"|"Simplex 4020"|"1"|"S"|"2000"|"15"|"0"|"Simplex point addressable smoke detectors."|"1"|"S"|"2000"|"2000"|"0"|"Existing kitchen hood, make-up air thru cafeteria unit vents."|"1"|"S"|"1995"|"5"|"9000"|"Recommend adding emergency lighting at exits on exterior of building."|"1"|"U"|"2007"|"5"|"158000"|"Ongoing maintenance. Replace equipment, install outdoors; add telecom, well, & lift pumps."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"|"Exterior lighting is poor."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"|"Gym & Aud need ventilation enhanced; MS Gym has loud noise concerns."|"0"|"1"|"1"|"1"|"1"|"1"|"0"||"1"|"1"|"1"|"1"|"1"|"1"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"|"WARMING"|"0"|"0"|"0"|"GOOD"|"District is considering a future consolidation of facilities."|"2469000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I Accept"|12/9/2010 1:06:35 PM| 188|"Nyack UFSD"|"50030403"|"Liberty Elementary School"|"0006"|"07/06/2010"|"142 LAKE ROAD "|"VALLEY COTTAGE "|" 10989"|"ANNUAL"|"03/01/2011"|"1961"|"56,035"|"2"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"444"|"K,1,2,3,4,5"|"0"|"1"|"1"|"444"|"0"|"0"|||"30"|"24,000"|"ADMIN,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,RSRCEROOM,OTHER"|"English as a second language"|"1"|"0"|"0"|"1"|"3,000"|"S"|"1986"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1961"|"20"|"0"|"3" service"|"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"$200.00"|"Scrape and paint pipe at two meters."|"1"|"UTIL"|"BELOW"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"1"|"S"|"1990"|"15"|"$2,500.00"|"Collapsing drywell outside Room #07"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"10"|"$20,000.00"|"Misc. re-surfacing and patching."|"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"10"|"$5,000.00"|"Misc. re-surfacing."|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"15"|"$1,500.00"|"Replace grid and tiles in misc. locations."|"0"||||"0"||"1"|"S"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"1"|"S"|"2008"|"10"|"0"|"Original sub-panels are antiquated."|"1"|"S"|"1990"|"10"|"0"||"1"|"1"|"S"|"1989"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1990"|"10"|"0"||"1"|"COMMON"|"S"|"1989"|"20"|"0"||"1"|"COMMON"|"S"|"1989"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"|"Scape and paint steel columns at 1961 building, classrooms and all lintels."|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"20"|"$5,000.00"|"Scrape and paint steel columns and lintels."|"1"|"MASONRY"|"S"|"1961"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"20"|"0"||"1"|"S"|"1990"|"0"|"$15,000.00"|"Add/replace rails at railroad tie steps to west street fence at high walls."|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1990"|"5"|"$225,000.00"|"Replace steel windows and slate sills."|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"10"|"0"||"1"|"PLASTIC"|"S"|"1990"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1989"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"1989"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"10"|"0"|"Two units."|"1"|"S"|"1989"|"20"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"Unit ventilation"|"S"|"2005"|"20"|"$500.00"|"Repair oil filter leak."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"Through wall units and ductless split (lounge) and ducted split at main office."|"1"|"S"|"1989"|"15"|"0"|"Vacuum at UV intakes"|"1"|"S"|"1989"|"10"|"$8,000.00"|"Replace two pumps in old boiler room."|"1"|"S"|"1989"|"20"|"0"|"Consider auditorium unit replacement to reduce noise."|"1"|"S"|"2005"|"20"|"0"||"0"|"S"|"1989"|"10"|"$5,000.00"|"Replace antiquated pull stations in halls and Multi-Purpose room."|"1"|"S"|"1989"|"10"|"$5,000.00"|"Limited coverage in corridors."|"1"|"S"|"1989"|"1989"|"0"||"1"|"S"|"1989"|"10"|"$500.00"|"Add fixtures at Multi-Purpose room."|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"0"|"FAIR"|"Auditorium/Cafeteria HVAC unit noisy - consider replacement."|"DAYLIGHT,FL_ FULL,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"Vacuum UV intakes at 1st floor."|"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"$293,200.00"|"S"|"0"|"DCAK, H2M"|"53 Hudson Avenue, Nyack, NY, 10960"|"845-353-1300"|"dc@DCAK-MSA.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/9/2010 3:19:25 PM| 190|"Union Springs CSD"|"05190104"|"High School"|"0001"|"7/13/10"|"239 Cayuga Street"|"Union Springs"|" 13160"|"ANNUAL"|"10/1/10"|"1936"|"103512"|"2"|"5"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"457"|"7,8,9,10,11,12"|"0"|"0"|"1"|"457"|"0"|"0"|||"27"|"20904"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,SCIENCELAB,SPECED,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"15"|"0"||"1"|"S"|"1959"|"10"|"0"|"On site gas well"|"1"|"UTIL"|"BELOW"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"U"|"2005"|"5"|"4000"|"Drainage ditches associated with the retention basin require dredging to restore flow"|"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"MUNI,ONSITE,OTHER"|"to daylight"|"1"|"U"|"2005"|"5"|"5000"|"Recommend cleaning outfalls - over grown w/ vegetation"|"0"||||"0"||"1"|"U"|"2005"|"5"|"18000"|"Recommend dredging basin to restore storage capacity"|"0"||||"0"||"1"|"S"|"2005"|"25"|"0"|"CDS Unit (approved by DEC). Requires annual cleaning"|"1"|"ASPHALT"|"S"|"2005"|"5"|"18000"|"Recommend re-striping & sealing cracks"|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"U"|"2005"|"5"|"231000"|"N"|"Recommend renovating south baseball field ; re-spray & line running track"|"RECONCRETE"|"1"|"1"|"0"|"0"|"0"|"0"|"S"|"2005"|"5"|"15000"|"Select areas of foundation are cracking due to settlement & lack of C.J.'s"|"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2005"|"5"|"35000"|"Recommend patching/painting plaster (i.e. stairwells)"|"1"|"S"|"2010"|"20"|"0"|"ACM plaster ceiling exists in 1936 wing classrooms"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"S"|"2010"|"5"|"75000"|"Many door hardware sets replaced 2010 but consider replacing original doors"|"1"|"S"|"1936"|"15"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"1"|"S"|"2005"|"15"|"0"||"1"|"E"|"2010"|"20"|"0"|"Replaced @ original HS/MS corridors 2010."|"1"|"1"|"S"|"2010"|"5"|"158000"|"Wireless clock installed in 2010; replace call switch PA headend"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2009"|"5"|"91000"|"Recommend replacing @ rooms 117, 118, 120-124, 127, faculty lounge, 204, 206, 207, 210, 215"|"1"|"INSTRUCT,COMMON"|"S"|"2005"|"5"|"193000"|"Recommend abating VAT @ rooms 126, 128,130, 132, 134, 208, 214, 216-221, PC support"|"1"|"COMMON"|"S"|"2005"|"20"|"0"||"1"|"INSTRUCT"|"U"|"2005"|"5"|"44000"|"Recommend refinishing @ rooms 203, 205, 211-213, 205f, faculty lounge"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"1"|"0"|"0"|"Corrosion observed on deck-joist in crawlspace"|"0"|"0"|"1"|"S"|"2005"|"15"|"0"||"CONCRETE,MASONRY"|"1"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"2005"|"5"|"25000"|"Recommend brick re-pointing and caulking in various areas"|"1"|"MASONRY"|"S"|"1959"|"15"|"0"|"Recommend Owner have chimney inspected due to age."|"1"|"MASONRY"|"S"|"2005"|"25"|"0"||"S"|"S"|"0"|"1"|"2009"|"20"|"0"|"Replaced with EXCEL funds."|"1"|"S"|"2010"|"5"|"20000"|"Recommend restoring two stairs - brick re-pointing-caulk"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"5"|"13000"|"Recommend replacing five single pane windows. re-pointing pre-cast sills."|"METONMET,WOODONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"15"|"0"||"1"|"PLASTIC"|"S"|"2005"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2005"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2005"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"15"|"0"|"Two high efficiency domestic water heater installed 2010."|"1"|"S"|"2005"|"10"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2005"|"30"|"0"|"HW heat exchangers for new addition"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2009"|"25"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"5"|"61000"|"Recommend cleaning corridor relief ductwork & replace control dampers"|"1"|"S"|"2005"|"10"|"0"|"DDC with pneumatic operation"|"1"|"S"|"2005"|"15"|"0"|"Exg FCI 7100 system"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2009"|"2009"|"0"|"Exg sprinkler system in Aud and Ansul system in kitchen"|"1"|"S"|"2010"|"15"|"0"||"0"||||"160000"|"Recommend adding emergency generator (owner request)"|"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||"FULL"||"1"||"GOOD"||"1166000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson Street, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/9/2010 3:56:15 PM| 192|"Nyack UFSD"|"50030403"|"FIELD HSE BUS GARAGE "|"5019"|"05/06/2010"|"30 CHRISTIAN HERALD RD "|"UPPER NYACK "|" 10960"|"ANNUAL"|"3/1/2011"|"1990"|"7238"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Sport team lockers and maintenance garage"|"0"||"0"|"0"|"0"||||||"0"|"0"|"OTHER"|"Locker Room"|"0"||||||||"0"|"1,000 gallon double wall gasoline storage"|"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"$100.00"|"Scrape and paint piping."|"1"|"UTIL"|"BELOW"|"S"|"1990"|"5"|"$65,000.00"|"Replace"|"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"SURFACEH2O"||"1"|"S"|||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"5"|"$15,000.00"|"1000 SF asphalt, 1400 SF topcoat, 250 LF curb, raise paving at tank."|"1"|"ASPHALT"|"S"|"1990"|"5"|"$1,000.00"|"Replace 150 SF by team exit doors."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"$2,000.00"|"Point cracked joints and patch paint."|"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"10"|"$70,000.00"|"Replace 100 12" x 30" lockers."|"1"|"S"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"$7,000.00"|"Replace (17) non-functioning fluorescents with T-8 fixtures. Noisy ballasts at garage and boiler rooms."|"1"|"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1990"|"20"|"$6,000.00"|"Damaged ceramic tile."|"0"|||||"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"15"|"$3,000.00"|"Scrape and paint lintels, replace soffit vents, paint fascias and soffits."|"1"|"MASONRY"|"S"|"1990"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"10"|"$4,100.00"|"Replace 2 west doors and frames, wather-strip north door."|"1"|"S"|"1990"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1990"|"10"|"$7,500.00"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"|"No gutters, leaders, missing soffit vent screens."|"S"|"1990"|"10"|"$1,000.00"|"Gutters and leaders."|"1"|"PLASTIC"|"S"|"1990"|"10"|"0"||"1"|"COPPER"|"S"|"1990"|"20"|"$1,000.00"|"Insulate"|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1990"|"25"|"0"||"1"|"NAT_GAS"|"S"|"1990"|"10"|"$500.00"|"Unions leaking."|"1"|"S"|"1990"|"10"|"$7,500.00"||"0"||"1"|"FURNACE"||"S"|"1990"|"10"|"$25,000.00"|"Replace furnaces."|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"2"|"0"|"Window units at offices."|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"$1,000.00"|"Reinsulate all piping in mech. room"|"1"|"S"|"1990"|"20"|"$1,500.00"|"Clean all ductwork."|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"|"Limited coverage at corridors."|"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"|"1"|"500"||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"$218,200.00"|"S"|"1"|"DCAK-MSA Architecture"|"53 Hudson Avenue, Nyack, NY, 10960"|"845-353-1300"|"dc@DCAK-MSA.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/9/2010 4:46:19 PM| 193|"Nyack UFSD"|"50030403"|"Nyack High School"|"0021"|"03/31/2010"|" 30 Christian Herald Drive "|"NYACK "|" 10960"|"ANNUAL"|"03/01/2011"|"1990"|"153,000"|"3"|"4"|"11"|"DISTRICT"|"INSTRUCT"||"911"|"9,10,11,12"|"0"|"1"|"0"|"911"|"0"|"0"|||"49"|"39,200"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1990"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"|"4" service with booster pump"|"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"|"Not located"|"1"|"S"|"1990"|"20"|"$250.00"|"Scrape and paint pipe at both meters."|"1"|"UTIL"|"BELOW"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"1"|"S"|"1990"|"20"|"$2,000.00"|"Raise NW curb inlet, clogged area drain at west stage exit."|"1"|"S"|"1990"|"20"|"0"|"At Christian Herald Road"|"0"|||||||"0"||"0"||||"0"||"1"|"S"|"1990"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"5"|"$200,000.00"|"Replace 250LF of curb and approx. 30,000sf paving repairs."|"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"10"|"$10,000.00"|"Replace 1700SF walks."|"0"||||"0"||"1"|"S"|"1990"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1990"|"20"|"$20,000.00"|"Install exterior zipper drain to stop east classroom leaks."|"1"|"S"|"1990"|"40"|"0"||"1"|"S"|"1990"|"15"|"$10,000.00"|"Misc. repairs at window walls, gym wall cracks."|"1"|"S"|"1990"|"10"|"$6,000.00"|"Damaged, sagging tiles to be replaced at numerous locations throughout."|"1"|"S"|"1990"|"15"|"0"|"No accessible lockers."|"1"|"S"|"S"|"1990"|"15"|"$9,200.00"|"Hardware repair/replacement.Hardware has 10 yrs. +/- left. Remove stops from rated doors."|"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"3"|"$16,000.00"|"Replace warn and damaged carpet at faculty offices and music room."|"1"|"INSTRUCT,COMMON"|"S"|"1990"|"10"|"$10,000.00"|"Misc. repairs to cracked, damaged and missing tiles throughout."|"1"|"COMMON"|"S"|"1990"|"15"|"0"||"1"|"COMMON"|"S"|"1990"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"20"|"0"|"Expansion cracks in floor rooms 305-308."|"MASONRY,STEEL"|"0"|"1"||"1"|"1"|"0"|"1"|"0"||"S"|"1990"|"20"|"$250,000.00"|"Deteriorating mortar failed tests. Replace numerous locations, seal joints, misc., flashing/wall repairs."|"1"|"MASONRY"|"S"|"1990"|"20"|"0"||"1"|"MASONRY"|"S"|"1990"|"20"|"0"||"S"|"S"|"0"|"1"|"1990"|"15"|"$500.00"|"Weatherstrip north exit saddle at music wing exit."|"1"|"S"|"1990"|"2"|"$90,000.00"|"Landing at field steps, add steps to third baseline, add rails to B and C entry steps, replace entry C steps, rebuild north wall steps."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1990"|"15"|"$1,000.00"|"Replace rollers on sticking windows. Repair escape windows at rooms #112 and #307."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"|"Cracked skylight at teacher prep. Insufficient walk pads. Sculpture at entry not in design loads."|"S"|"1990"|"5"|"$1,000,000.00"|"Replace roofing. Check structure or remove sculpture."|"1"|"PLASTIC"|"S"|"1990"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"20"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1990"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1990"|"20"|"0"||"0"||||"0"||"1"|"S"|"1990"|"20"|"$2,000.00"|"Roof top condensers near end of service life. Replace refrigerant insulation."|"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"|"Pneumatic valves, consider replacement with digital."|"1"|"S"|"1990"|"3"|"$90,000.00"|"Recommend replacement with Addressable System."|"1"|"S"|"1990"|"3"|"0"|"Replace smoke detectors. Cost included in Fire Alarm System cost above."|"1"|"S"|"1990"|"1990"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"10"|"0"|"Generator tested and run smoothly."|"1"|"1"|||"GOOD"||"FAIR"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"COMMSYS,KITCHEN,HVAC,FIREALARM,FRIDGE,LIGHTING"|"FULL"||"1"||"GOOD"||"$1,706,950.00"|"S"|"1"|"DCAK-MSA Architecture"|"53 Hudson Avenue, Nyack, NY, 10960"|"845-353-1300"|"dc@DCAK-MSA.com"|"Drazen Cackovic"|"022124"|"I ACCEPT"|12/9/2010 6:24:08 PM| 194|"Allegany - Limestone CSD"|"04030206"|"Allegany Elementary "|"0003"|"8/11/2010"|"120 Maple Avenue"|"Allegany"|" 14706"|"ANNUAL"|"07/01/2011"|"1958"|"114683"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"562"|"Pre-K,K,1,2,3,4,5"|"0"|"0"|"1"|"562"|"0"|"0"|||"34"|"30952"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"15"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"10"|"0"||"1"|"CONCRETE"|"S"|"2009"|"10"|"48750"||"1"|"E"|"2005"|"15"|"0"|"some rust to clean up"|"1"|"E"|"1958"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"S"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"1"|"E"|"2005"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"15"|"0"||"1"|"COMMON"|"S"|"2002"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1958"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"20"|"27378"|"some leaking at upper gymnasium walls-masonry sealer should be applied"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2009"|"15"|"0"||"0"|"S"|"2005"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"E"|"Y"|"2005"|"15"|"3900"|"upper windows at old gymnasium need replacement."|"METONMET,OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"10"|"0"|"kindergarten wing will need replacement in 5-10 years"|"1"|"GLASS"|"S"|"2005"|"20"|"0"||"1"|"COPPER"|"S"|"2005"|"20"|"0"||"1"|"COPPER"|"S"|"2005"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2005"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2005"|"2005"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"0"|"E"|"0"|"Kideney Architects, PC"|"200 JJ Audubon Parkway"|"716-636-9700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/10/2010 10:09:50 AM| 197|"Union Springs CSD"|"05190104"|"Stone School House"|"0002"|"7/13/10"|"239 Cayuga Street"|"Union Springs"|"13160"|"ANNUAL"|"10/1/10"|"1853"|"2070"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT"||"0"|"UNGRD"||"0"|"1"||||||"1"|"1200"|"AV,COMPROOM,MULTIPURPO"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2009"|"40"|"0"||"1"|"MUN_UTILIT"|"E"|"2009"|"40"|"0"||"1"|"E"|"2009"|"40"|"0"||"1"|"OTHER"|"BELOW"|"E"|"2009"|"40"|"0"|"Fed from Jr./Sr. HS"|"0"||||"0"||"1"|"E"|"2005"|"20"|"0"|"Lawns drain to adjacent MS/HS property"|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"E"|"2009"|"25"|"0"||"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"30"|"0"|"Stone foundation walls"|"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"E"|"2009"|"25"|"0"||"0"||||"0"||"1"|"S"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"25"|"0"||"0"||||"0"||"1"|"1"|"E"|"2009"|"30"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|"S"|"2009"|"25"|"0"|"LAN and PA system connected to HS"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2009"|"15"|"0"||"0"|||||"0"||"1"|"INSTRUCT"|"E"|"2009"|"15"|"0"|"Refinished 2009"|"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"30"|"0"||"OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"30"|"0"|"Stone exterior walls"|"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"20"|"0"||"1"|"S"|"2009"|"30"|"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"Y"|"2009"|"30"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2009"|"20"|"0"||"1"|"GALVANIZED"|"S"|"2009"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2009"|"10"|"0"|"New "point-of-use" water heater."|"1"|"S"|"2009"|"30"|"0"|"ADA compliant"|"1"|"CV"|"1"|"FURNACE"||"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"|"Natural gas to furnace"|"1"|"S"|"2009"|"10"|"0"|"A/C split system"|"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"30"|"0"||"0"||||"0"||"1"|"S"|"2009"|"15"|"0"|"Connected to HS FACP"|"1"|"S"|"2009"|"15"|"0"|"Connected to HS FACP"|"0"||||"0"||"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"|"Recently renovated."|"0"|"E"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/10/2010 11:29:08 AM| 201|"Commack USFD"|"58041003"|"Burr Road Maintenance Shop"|"3003"|"02/16/2010"|"200 Burr Road"|"Commack, NY"|"11725"|"ANNUAL"|"05/01/2011"|"1972"|"3600"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Vehicle Repair Shop and Garage"|"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"OTHER"|"Vehicle Repair Shop and Garage"|"0"||||||||"0"||"0"|||"1972"|"14"|"0"||"1"|"SITESEPT"|"S"|"1972"|"19"|"0"||"1"|"S"|"1972"|"14"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1995"|"39"|"0"||"1"|"S"|"1998"|"19"|"0"||"0"||||"0"||"1"|"S"|"1972"|"19"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"24"|"0"||"0"|"OTHER"|"S"|"1980"|"29"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"19"|"0"||"1"|"S"|"1972"|"19"|"0"||"1"|"S"|"1972"|"19"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1972"|"9"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"39"|"0"||"1"|"S"|"2006"|"25"|"0"||"1"|"1"|"S"|"2000"|"19"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2006"|"20"|"0"||"1"|"COMMON"|"S"|"1972"|"19"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"19"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"19"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1972"|"9"|"0"||"0"||||"0"||"0"|||||"0"||"0"|"ALUMINUM"|"S"|"NA"|"1972"|"9"|"0"||"METONMET,WOODONWOOD"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1985"|"9"|"0"||"1"|"PLASTIC"|"S"|"1972"|"9"|"0"||"1"|"COPPER"|"S"|"1972"|"14"|"0"||"1"|"IRON"|"S"|"1972"|"14"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"14"|"0"||"1"|"S"|"1972"|"14"|"0"||"0"||"1"|"OTHER"|"Gas ceiliing mounted heaters"|"S"|"2010"|"14"|"0"|"Two gas fired heaters were replaced."|"1"|"S"|"1972"|"14"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1983"|"37"|"0"||"0"|"0"|"20,000"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 20,000"|"S"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/10/2010 2:05:51 PM| 202|"Newfield CSD"|"61090104"|"Maintenance Building"|"3004"|"08/12/2010"|"247 Main Street"|"Newfield"|" 14867"|"ANNUAL"|"09/01/2011"|"1939"|"3612"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Maintenance/Storage/Generator"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GYM"||"0"|"0"|||"1"|"0"|"0"|"1"|"1000"|"S"|"1939"|"0"|"$5,000"|"Fill with concrete slurry to permanently close tank per NYSDEC closure regulations."|"1"|"MUN_UTILIT"|"S"|"1932"|"5"|"0"|"Water service appears satisfactory. Revisit in 5 years."|"1"|"MUN_UTILIT"|"S"|"1985"|"15"|"0"||"1"|"S"|"2009"|"50"|"0"|"Service just replaced."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"20"|"0"||"1"|"S"|"2009"|"25"|"0"||"0"||||"0"||"1"|"S"|"2009"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"5"|"0"|"See Elemenatry School for removal and replacement of asphalt in vicinity of Maintenance Building."|"1"|"CONCRETE"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"1"|"1"|"1"|"1"|"0"|"0"|"S"|"1939"|"10"|"$20,000"|"There is evidence of moisture damage and freezing/thaw damage. Repair approx. 132 linear feet."|"1"|"S"|"1939"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1939"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1999"|"30"|"$7,500"|"Install 50 new power outlets throughout building."|"1"|"S"|"1975"|"0"|"$9,750"|"Install 30 new fluorescent fixtures throughout building. Install 3 new shoebox fixtures on building exterior."|"1"|"1"|"S"|"1974"|"0"|"$6,000"|"Add 3 phones throughout building. Add 3 computer outlets in office. Add 3 PA speakers and call stations throughout building."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1939"|"20"|"0"||"MASONRY"|"1"|"1"||"1"|"0"|"0"|"1"|"1"||"S"|"2005"|"10"|"$23,000"|"Unit masonry @ base wall @ back side is crumbling due to water infiltration. Remove/replace. Remove parging & lath/reparge entire back wall. Trim @ overhead doors damaged, replace to match existing."|"1"|"MASONRY"|"S"|"1939"|"20"|"0"||"1"|"MASONRY"|"S"|"1939"|"15"|"0"||"S"|"S"|"0"|"1"|"2000"|"10"|"$500"|"Door to generator has a knob, replace with a lever set for accessibiilty."|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1939"|"0"|"$26,000"|"Windows falling apart, end of useful life. Possible pcb/asbestos caulking will need to be removed. Remove/replace with new aluminum famed insulating glazing. 6 @ 30 sf ea."|"WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"5"|"$77,500"|"Back of bldg needs new gutter/downspout system to avoid further moisture damage to bldg. Also, provide straps to secure gutter to bldg. Roof satisfactory condition, revisit within 5 years. Consider replacing if no longer under warranty."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1939"|"5"|"0"|"Water piping appears satisfactory. Revisit in 5 years. Provide electric, instantaneous water heater for toilet room."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1939"|"5"|"0"|"Drainage system appears satisfactory. Revisit in 5 years."|"0"|||||"0"||"1"|"S"|"1939"|"3"|"$4,500"|"Install hand sink in Shop Area. "|"0"||"1"|"BOILERSTEA"||"S"|"1939"|"0"|"$40,000"|"Replace fuel oil steam boiler with gas hot water boiler."|"1"|"S"|"2009"|"25"|"0"|"A new gas service was provided to the building to serve new Emergency Generators."|"0"||||"0"||"1"|"S"|"1939"|"0"|"$15,000"|"Install ventilation in vehicle bays and toilet rooms and office."|"1"|"S"|"1939"|"0"|"$40,000"|"Replace steam system with hot water unit heaters. Remove existing steam piping and radiation."|"0"||||"0"||"0"||||"0"||"1"|"S"|"1999"|"10"|"$3,000"|"Add 6 FA horn/strobes throughout building."|"1"|"S"|"1999"|"10"|"$7,000"|"Add 14 detectors/pull stations throughout building."|"0"|"S"|||"0"||"1"|"S"|"1974"|"0"|"$5,000"|"Add 10 battery pack emergency lights throughout building."|"1"|"S"|"2009"|"20"|"0"||"1"|"1"|"15000"|"Replace fixtures and modify toilet room for handicap accessibility."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"FAIR"|"There is no air ventilation system."|"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"||"0"|"0"|"0"|"FAIR"||"$399,425"|"S"|"0"|"Tetra Tech Architects and En"|"10 Brown Road Ithaca NY 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/10/2010 2:44:58 PM| 203|"BOCES Madison-Oneida"|"25900000"|"Adult Education/ Administration"|"1028"|"08/20/2010"|"SPRING ROAD CAMPUS "|"VERONA "|" 13478"|"ANNUAL"|"08/15/2011"|"1992"|"2420"|"2"|"1"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"|"meetings and seminars"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"0"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"SITESEPT"|"S"|"2002"|"15"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"UTIL,SELF"|"BELOW"|"S"|"1992"|"17"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"3000"|"0"||"1"|"CONCRETE"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"16"|"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"12"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"12"|"0"||"0"||||"0"||"1"|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"8"|"0"|"repairs need to be made"|"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1992"|"6"|"0"||"1"|"COMMON"|"S"|"1992"|"6"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE,WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"16"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1992"|"8"|"0"|"need paint"|"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"1"|"2010"|"10"|"0"||"1"|"WOODCLAD"|"S"|"NA"|"1992"|"6"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1992"|"11"|"0"||"1"|"IRON,COPPER"|"S"|"1992"|"11"|"0"||"1"|"ELECTRIC"|"S"|"2009"|"12"|"0"||"1"|"S"|"1992"|"9"|"0"||"1"|"OTHER"|"1"|"FURNACE"||"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"8"|"0"||"1"|"S"|"1992"|"8"|"0"||"0"|"S"|"1992"|"8"|"0"||"1"|"S"|"1992"|"9"|"0"||"1"|"S"|"1992"|"6"|"0"||"1"|"S"|"1992"|"6"|"0"||"1"|"S"|"1992"|"6"|"0"||"0"||||"0"||"1"|"S"|"1992"|"6"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"0"|"30000"|"Rarly needed because of building function and layout"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"WARMING"||"0"|"1"|"GOOD"||"30000"|"S"|"1"|"William J. Murphy CO"|"303 E Noyes BLVD"|"315-363-3682"|"murphy@twcny.rr.com"|"Wiliam J. Murphy"|"041799"|"I accept"|12/10/2010 2:51:47 PM| 205|"North Colonie CSD"|"01062306"|"Latham Ridge Elementary School"|"0011"|"06/04/2010"|"6 Mercer Lane"|"Latham"|"12110"|"ANNUAL"|"01/01/2011"|"1966"|"66,690"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"389"|"K,1,2,3,4,5,6"|"0"|"1"|"0"|"389"|"0"|"0"|||"21"|"19,120"|"ADMIN,ART,CAFE,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"|"2003 Backflow preventer"|"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"|"Repair/replace floor drains."|"1"|"S"|"2003"|"20"|"0"||"1"|"UTIL"|"BELOW"|"U"|"2003"|"5"|"325,000"|"Conduit at municipal pole at road needs repair/replacement."|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2009"|"5"|"0"|"Additional drainage improvement planned 2011."|"1"|"S"|"2009"|"5"|"0"||"1"|"S"|"2009"|"5"|"0"|"Culverts cleared in 2009, upgrades planned 2011."|"0"|"MUNI"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"340,000"|"Bus loop drop off paving planned for 2011."|"1"|"CONCRETE,ASPHALT"|"S"|"2003"|"5"|"0"|"Replace front walk curbs 2011."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1990"|"20"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"|"Chiller wall removed 2006-07"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"10"|"0"|"ACM plaster above classroom windows."|"1"|"S"|"2004"|"5"|"135,000"|"Lobby ACM plaster shoud be replaced."|"0"||||"0"||"1"|"U"|"U"|"2004"|"5"|"35,000"|"Doors missing at 1966 toilets, upgrade hardware, closers/hold opens."|"1"|"S"|"1966"|"20"|"0"|"Ship ladder to boiler room."|"0"||||"0"||"1"|"1"|"S"|"2003"|"10"|"0"|"MDP in courtyard mech rm."|"1"|"S"|"2003"|"5"|"35,000"|"Upgrade gym to T5 planned 2011."|"1"|"1"|"S"|"2003"|"5"|"151,000"|"Replace original PA, replace clocks, phones ok - 1996."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"|"At kindergarten, music, computer, etc."|"1"|"INSTRUCT"|"S"|"2004"|"5"|"61,000"|"CAF and s. classrooms replace 2010 with VCT, north wing to be replaced 2011."|"1"|"COMMON"|"S"|"1966"|"10"|"0"|"Terrazzo at corridors, cafeteria spider cracks at 1991 corridor."|"1"|"INSTRUCT"|"S"|"1966"|"10"|"0"|"Stage & gym."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"2004"|"10"|"204,000"|"1991 composite panel to be replaced 2011. Paint conc."|"1"|"METAL"|"S"|"1991"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"10"|"12,000"|"1991 HM doors, planned replace w/FRP."|"1"|"S"|"2004"|"10"|"11,000"|"PT wood stairs at playground in fair shape."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"10"|"50,000"|"Some broken screens 1991 wing. Reflash front 6 section."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"650,000"|"1996 ballast roof leaks repaired seasonally. For re-roof."|"1"|"PLASTIC"|"S"|"2004"|"10"|"0"||"1"|"COPPER"|"S"|"2003"|"5"|"20,000"|"Replace original shut offs."|"1"|"IRON"|"S"|"2003"|"10"|"25,000"|"Replace floor drains."|"1"|"NAT_GAS"|"S"|"2003"|"10"|"0"|"Corrision at fittings."|"1"|"S"|"2003"|"10"|"0"|"Original fixtures have replaced trim - ok."|"1"|"CV"|"1"|"BOILERWATE"||"U"|"1966"|"2"|"460,000"|"Boiler replacement planned 2011."|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"|"Central chiller non-functioning, window AC ok."|"1"|"S"|"2003"|"10"|"585,000"|"Replace original UVs, gym, auditorium AHUs. Kitchen dishwasher exhaust."|"1"|"U"|"2003"|"5"|"50,000"|"Replace original toilet and corridor heat units wing pumps."|"1"|"S"|"2003"|"10"|"0"|"Regular cleaning of ductwork."|"1"|"S"|"2003"|"5"|"35,000"|"Electric and pneumatic DDC"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2004"|"2004"|"0"||"1"|"S"|"2003"|"15"|"0"|"Review emergency lighting coverage with current code."|"0"||||"0"||"1"|"1"|"35,000"|"Improve accessibility, parking and entrance and auto door opener."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"|"Add OCC sensors in 1966, 1991 wings."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"1"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"3,222,000"|"U"|"1"|"CSArch"|"40 Beaver Street, Albany 12207"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I accept"|12/10/2010 3:34:16 PM| 207|"Spencerport CSD"|"26100106"|"Bernabi Elementary"|"0002"|"5/24/2010"|"1 Bernabi Road"|"SPENCERPORT "|" 14559"|"ANNUAL"|"9/01/2011"|"1957"|"70,571"|"1"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"380"|"K,1,2,3,4,5"|"0"|"0"|"1"|"380"|"0"|"0"|||"48"|"32,450"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,KITCHEN,LIBBRARY,MUSIC"||"1"|"1"|"12,000"|"0"|"0"|"S"|"1997"|"9"|"0"|"No leaks reported."|"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"|"Meter and primary backflow are located in hot box at Cosgrove School. 8" service from Monroe County Water Authority."|"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"30"|"0"|"Underground primary from Spencerport Municipal Electric w/substation in electrical room."|"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"MUNI"||"1"|"S"|"1957"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"5"|"235,266"|"Spot repairs, overlay north lot, mill and resurface bus loop, reconstruct parking areas west of the school."|"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"5"|"80,538"|"Replace front concrete sidewalks, seal asphalt walks."|"1"|"S"|"2004"|"20"|"6,137"|"Add mulch, secure tire climb, replace " roller drum" unit, cover/modify sharp edges on "truck unit" add path."|"1"|"S"|"1988"|"10"|"24,706"|"N"|"Resurface tennis courts"|"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"30"|"0"||"1"|"S"|"1957"|"30"|"0"||"1"|"S"|"1990"|"39"|"5,068"|"Replace toilet partitions in boy's locker room and East wing boy's gang bathroom."|"1"|"S"|"2008"|"5"|"38,588"|"Replace delaminating fiberglass tiles."|"1"|"S"|"2008"|"30"|"117,835"|"East wing corridor lockers scheduled for replacement in 2011. Locker room lockers in unsatisfactory condition but are no longer in use."|"1"|"S"|"S"|"1990"|"10"|"81,648"|"Consider upgrade locksets to ADA lever style."|"1"|"S"|"1957"|"22"|"0"|"Stairs to stage, mechanical room and roof."|"0"||||"0"||"1"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"E"|"1990"|"2"|"209,593"|"Upgrade PA system."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"13"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1990"|"5"|"376,845"|"VAT flooring losing bond, monitoring and patching required until replacement."|"1"|"COMMON"|"S"|"1990"|"19"|"0"||"1"|"INSTRUCT"|"S"|"1957"|"29"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"30"|"0"||"MASONRY"|"0"|"0"|"Vertical expansion cracks"|"1"|"0"|"1"|"0"|"0"||"S"|"1990"|"30"|"17,699"|"Replace joint sealant @ exterior wall vertical expansion joints."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2007"|"3"|"30,375"|"Roof access door critical failure"|"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"22"|"0"||"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"23"|"1,296"|"Clean roof drain screens, trim overhanging trees."|"1"|"PLASTIC"|"S"|"2008"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"20"|"0"|"Meter and primary backflow preventer have been relocated to hot box outside Cosgrove facility."|"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"2008"|"1"|"25,515"|"Flashing of vents through the roof has reduced size vs. NYS Code required 3". Configuration will cause vents to freeze over in winter months."|"1"|"NAT_GAS"|"E"|"2003"|"1"|"8,506"|"Provide check stops and vacuum breakers. Repair east wing hot water temperature."|"1"|"S"|"2000"|"3"|"33,791"|"Upgrade faucets and flushers to be automatic."|"0"||"1"|"BOILERWATE"|"unit ventilation"|"S"|"2005"|"20"|"0"|"All equipment appears in good order"|"1"|"S"|"2003"|"20"|"0"|"1957 firetube boiler served by fuel oil. Aerco boilers and domestic water heater served by natural gas. Fuel oil and natural gas piping appears to be good condition."|"1"|"S"|"2008"|"15"|"0"|"Split system AC units provide cooling to offices and faculty lounge. Unit ventilators with DX cooling coils provide cooling to library and computer room. All equipment appears in good order."|"1"|"S"|"2008"|"20"|"9,072"|"Ventilation required in Rms 302A, 411 & 415."|"1"|"S"|"2008"|"20"|"0"|"All equipment appears in good condition"|"1"|"S"|"2008"|"20"|"0"|"Ductwork used in gym and cafetorium for supply and return. Exhaust ductwork removes air from toilet rooms, locker room and storage spaces. All observed ductwork appears to be in good condition."|"1"|"S"|"2008"|"10"|"0"|"Invensys control system controls setpoints and schedules of operation for majority of mechanical equipment. Control systems appear to be in good condition."|"1"|"S"|"2001"|"3"|"191,730"|"Replace fire alarm system with a fully addressable system."|"1"|"S"|"2001"|"3"|"31,050"|"Replace smoke detection devices."|"1"|"S"|"2003"|"2003"|"0"|"Building not sprinklered. Ansul system at kitchen hood."|"1"|"S"|"2003"|"15"|"42,525"|"Replace emergency lighting in existing building only."|"0"||||"0"||"1"|"1"|"101,250"|"Consider wheelchair lift to stage. Entrances and exits should be more accessible. Provide ADA lever style locksets. Upgrade gang toilet rooms to ADA east/west classroom wings"|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"|"All lighting observed was well maintained. Consider replacing MH fixtures in gym and cafeteria seating with high performance fluorescent high-bays"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Unit ventilators provide ventilation for all classrooms and most offices. Clean filters located near units indicate school is conscientious about changing filters."|"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"0"||"FULL"|"0"|"1"|"0"|"GOOD"||"7,199,512"|"S"|"1"|"LaBella Associates, P.C."|"300 State Street, Rochester, NY 14614"|"585-454-6110"|"mshort@labellapc.com"|"Michael E. Short"|"032717"|"I ACCEPT"|12/10/2010 4:08:04 PM| 208|"West Genesee CSD"|"42010106"|"Stonehedge Elementary"|"0010"|"7/27/10"|"400 Sanderson Drive"|"Camillus"|"13031-1699"|"ANNUAL"|"9/1/2011"|"1961"|"114,785"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"892"|"K,1,2,3,4,5"|"0"|"0"|"0"|"892"|"0"|"0"|||"53"|"49,823"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"35"|"$200,000"|"No work proposed"|"1"|"MUN_UTILIT"|"S"|"1966"|"35"|"$200,000"|"No work proposed"|"1"|"S"|"1966"|"35"|"$40,000"|"No work proposed"|"1"|"UTIL"|"BELOW"|"S"|"1966"|"35"|"$84,000"|"$84,000 work proposed"|"1"|"E"|"2005"|"35"|"$200,000"|"$25,000 work proposed"|"1"|"S"|"2005"|"20"|"$10,000"|"No work proposed"|"1"|"S"|"2005"|"25"|"$25,000"|"$25,000 work proposed"|"1"|"S"|"1966"|"10"|"$10,000"|"$7,000 work proposed"|"0"|||||||"0"||"1"|"S"|"2005"|"20"|"$10,000"|"$15,000 work proposed"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2005"|"20"|"$200,000"|"$29,000 work proposed"|"1"|"CONCRETE"|"E"|"2005"|"20"|"$100,000"|"$45,000 work proposed"|"1"|"S"|"2001"|"15"|"$150,000"|"$10,000 work proposed"|"1"|"S"|"2005"|"20"|"$200,000"|"N"|"$56,000 work proposed"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1966"|"30"|"$2,000,000"|"No work proposed"|"1"|"S"|"1994"|"20"|"$200,000"|"No work proposed"|"1"|"S"|"1994"|"20"|"$400,000"|"$78,000 work proposed"|"1"|"S"|"1994"|"10"|"$650,000"|"$80,000 work proposed"|"1"|"S"|"1994"|"5"|"$100,000"|"$8,000 work proposed"|"1"|"S"|"S"|"1994"|"15"|"$500,000"|"$122,000 work proposed"|"1"|"S"|"1966"|"20"|"$200,000"|"no work proposed"|"1"|"S"|"1994"|"20"|"$150,000"|"no work proposed"|"1"|"1"|"S"|"1966"|"15"|"$425,000"|"$105,000 work proposed"|"1"|"S"|"1994"|"15"|"$220,000"|"$140,000 work proposed"|"1"|"1"|"S"|"1994"|"15"|"$100,000"|"$100,000 work proposed"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1994"|"5"|"$8,000"|"$8,000 work proposed"|"1"|"INSTRUCT"|"S"|"1994"|"20"|"$113,000"|"$113,000 work proposed"|"1"|"COMMON"|"S"|"1994"|"25"|"$32,000"|"$32,000 work proposed"|"1"|"INSTRUCT"|"S"|"1994"|"10"|"$8,000"|"NO work proposed"|"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1966"|"30"|"$2,000,000"|"No work proposed"|"STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1966"|"20"|"$2,750,000"|"$194,000 work proposed. Some 1994 infills."|"1"|"MASONRY"|"S"|"1986"|"15"|"$185,000"|"no work proposed"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1986"|"10"|"$150,000"|"$47,000 work proposed"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"25"|"$200,000"|"No work proposed, 5 years remaining on remaining 1986 windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"25"|"$500,000"|"No work proposed"|"1"|"PLASTIC"|"S"|"2005"|"25"|"$500,000"|"no work proposed"|"1"|"COPPER"|"S"|"1994"|"15"|"$142,000"|"$142,000 work proposed"|"1"|"IRON"|"S"|"1994"|"15"|"$200,000"|"$70,000 work proposed"|"1"|"NAT_GAS"|"S"|"2009"|"20"|"$30,000"|"No work proposed"|"1"|"S"|"1994"|"15"|"$122,000"|"$67,000 work proposed"|"1"|"DD_MZ"|"1"|"BOILERWATE"||"S"|"1993"|"15"|"$120,000"|"no work proposed"|"1"|"S"|"1994"|"25"|"$24,000"|"no work proposed"|"1"|"S"|"1994"|"15"|"$1,000,000"|"$1,180,000 work proposed"|"1"|"S"|"1994"|"15"|"$100,000"|"$70,000 work proposed"|"1"|"S"|"1994"|"15"|"$300,000"|"$5,000 work proposed"|"1"|"S"|"1994"|"15"|"$50,000"|"$40,000 work proposed"|"1"|"S"|"1994"|"15"|"$100,000"|"$25,000 work proposed"|"1"|"S"|"1994"|"15"|"$125,000"|"$10,000 work proposed"|"1"|"S"|"1994"|"15"|"$125,000"|"no work proposed"|"1"|"S"|"1994"|"1994"|"$20,000"|"No work proposed"|"1"|"S"|"1994"|"15"|"$30,000"|"$10,000 work proposed"|"0"||||"0"|"$126,000 work proposed"|"1"|"1"||"$5,000 ADA signage work proposed"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"2,009,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"FAIR"||"$4,805,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/10/2010 4:55:06 PM| 209|"Weedsport CSD"|"05030104"|"Bus Garage"|"5009"|"08/03/2010"|"2910 Towpath Road"|"Weedsport"|" 13166"|"ANNUAL"|"09/01/2011"|"2001"|"19765"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus Garage/Maintenance Facility"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2001"|"15"|"0"||"1"|"SITESEPT"|"E"|"2001"|"15"|"0"||"1"|"E"|"2001"|"15"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2001"|"15"|"0"||"0"||||"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"15"|"0"||"1"|"CONCRETE"|"S"|"2001"|"15"|"0"|"Slab has settled near door"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2001"|"15"|"5000"|"Replace door and frame adjacent to wash bay"|"1"|"S"|"2001"|"25"|"0"|"Stairs to storage/mechanical mezzanine."|"0"||||"0"||"1"|"1"|"S"|"2001"|"30"|"0"|"GE A-Series panelboards with plenty of empty pole space."|"1"|"S"|"2001"|"15"|"0"||"1"|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"2001"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2001"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"18000"|"Gutters require replacement above OH doors."|"0"|||||"0"||"1"|"COPPER"|"S"|"2001"|"30"|"0"||"1"|"IRON,PVC"|"S"|"2001"|"40"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2001"|"10"|"26000"|"Replace flue for radiant HTRs."|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"5"|"17000"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"|"Existing Simplex 4004 Zone FACP"|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"S"|"2001"|"5"|"0"|"Maintenance Cost: LED exit signs, ceilings recessed battery packs"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"|"Lighting quality in building is good."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$66,000"|"S"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/12/2010 4:22:22 PM| 210|"Newfield CSD"|"61090104"|"New Field House"|"7009"|"08/12/2010"|"247 Main Street"|"Newfield"|"14867"|"ANNUAL"|"09/01/2011"|"2009"|"3715"|"2"|"0"|"0"|"DISTRICT"|"OTHER"|"Locker/Shower for Football team, concessions"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"40"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"40"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"30"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"25"|"0"||"1"|"ASPHALT"|"S"|"2009"|"25"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2009"|"40"|"0"||"1"|"E"|"2009"|"40"|"0"||"1"|"E"|"2009"|"40"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"E"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"40"|"0"||"1"|"S"|"2009"|"40"|"0"||"0"|"1"|"S"|"2009"|"40"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2009"|"40"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2009"|"40"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"40"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2009"|"20"|"0"||"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2009"|"40"|"0"||"0"|"IRON,COPPER"|"E"|"2009"|"40"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"15"|"0"||"1"|"E"|"2010"|"30"|"0"||"0"||"1"|"FURNACE"||"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2009"|"40"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"|"0"|"GOOD"||"0"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road Ithaca NY 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/13/2010 9:10:01 AM| 211|"Newfield CSD"|"61090104"|"Field House"|"0003"|"08/12/2010"|"247 Main Street"|"Newfield"|" 14867"|"ANNUAL"|"09/01/2011"|"1975"|"2304"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Locker/Shower for football team/storage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"20"|"0"|"Partial replacement of water line in 2009."|"1"|"MUN_UTILIT"|"S"|"1975"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1975"|"15"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"OTHER"|"Adjacent Stream"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2000"|"10"|"0"||"1"|"CONCRETE"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1975"|"30"|"0"||"0"||||"0"||"1"|"S"|"1975"|"15"|"0"||"1"|"S"|"1975"|"0"|"1,000"|"Gypsum ceilings need to be patched and painted."|"1"|"S"|"1975"|"10"|"0"||"1"|"S"|"S"|"1975"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1975"|"20"|"0"||"1"|"S"|"1975"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1975"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1975"|"30"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1975"|"30"|"2,000"|"Minor cracks at exterior wall, repoint joints."|"0"|||||"0"||"0"|||||"0"||"U"|"U"|"0"|"0"|"1975"|"0"|"12,000"|"All doors need to be replaced and are at the end of their useful life."|"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1975"|"5"|"0"|"Water distribution system appears satisfactory, revisit in 5 years."|"1"|"IRON,GALVANIZED"|"S"|"1975"|"5"|"0"|"Plumbing drainage system appears satisfactory, revisit in 5 years."|"0"|||||"0"||"1"|"NF"|"1975"|"5"|"0"|"Building being converted to storage, fixtures no longer used."|"0"||"1"|"OTHER"||"S"|"1975"|"10"|"0"|"Electric unit heater."|"1"|"S"|"1975"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1975"|"5"|"2,500"|"Add 5 battery pack emergency lights."|"0"||||"0"||"1"|"0"|"0"|"New field house accommodates accessible toilet facility requirements for the grandstands."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"||"1"|"OTHER"||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"||"GOOD"||"22,750"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/13/2010 9:51:26 AM| 213|"West Genesee CSD"|"42010106"|"District Office "|"3001"|"7/27/10"|"300 SANDERSON DRIVE "|"CAMILLUS "|" 13031"|"ANNUAL"|"9/1/2011"|"1997"|"6540"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Technology training for staff"|"0"||"0"|"1"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"42"|"$25,000"|"No work proposed"|"1"|"MUN_UTILIT"|"S"|"1997"|"42"|"$25,000"|"no work proposed"|"1"|"S"|"1997"|"35"|"$40,000"|"No work proposed"|"1"|"UTIL"|"BELOW"|"S"|"1997"|"35"|"$33,000"|"$33,000 work proposed"|"1"|"S"|"1997"|"15"|"$2,000"|"$11,000 work proposed"|"1"|"S"|"1997"|"5"|"$15,000"|"$25,000 work proposed"|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1997"|"10"|"$10,000"|"$5,000 work proposed"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"10"|"$200,000"|"No work proposed"|"1"|"CONCRETE"|"S"|"1997"|"10"|"$5,000"|"no work proposed"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"35"|"$93,000"|"$30,000 work proposed"|"1"|"S"|"1997"|"35"|"$30,000"|"no work proposed"|"1"|"S"|"1997"|"35"|"$63,000"|"$20,000 work proposed"|"1"|"S"|"1997"|"20"|"$62,000"|"$21,000 work proposed"|"0"||||"0"||"1"|"S"|"S"|"1997"|"20"|"$15,000"|"$5,000 work proposed"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"32"|"$42,000"|"$5,000 work proposed"|"1"|"S"|"1997"|"12"|"$28,000"|"$4,000 work proposed"|"1"|"1"|"S"|"1997"|"12"|"$14,000"|"$20,000 work proposed"|"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"5"|"$12,000"|"$4,000 work proposed"|"1"|"COMMON"|"S"|"1997"|"20"|"$28,000"|"$10,000 work proposed"|"1"|"COMMON"|"S"|"1997"|"20"|"$7,000"|"no work proposed"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"35"|"$47,000"|"$15,000 work proposed"|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"35"|"$93,000"|"$30,000 work proposed"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1997"|"20"|"$16,000"|"no work proposed"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1997"|"20"|"$23,000"|"$7,000 work proposed"|"WOODONMET"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"$93,000"|"$35,000 work proposed"|"0"|||||"0"||"1"|"COPPER"|"S"|"1997"|"32"|"$21,000"|"$3,000 work proposed"|"1"|"IRON"|"S"|"1997"|"12"|"$30,000"|"$2,000 work proposed"|"1"|"NAT_GAS"|"S"|"1997"|"7"|"$6,000"|"no work proposed"|"1"|"S"|"1997"|"12"|"$15,000"|"no work proposed"|"1"|"CV"|"1"|"FURNACE"||"S"|"1997"|"22"|"$21,000"|"no work proposed"|"1"|"S"|"1997"|"22"|"$4,000"|"no work proposed"|"1"|"S"|"1997"|"32"|"$35,000"|"$2,000 work proposed"|"1"|"S"|"1997"|"12"|"$35,000"|"no work proposed"|"0"||||"0"||"1"|"S"|"1997"|"32"|"$21,000"|"$5,000 work proposed"|"1"|"S"|"1997"|"22"|"$15,000"|"$2,000 work proposed"|"1"|"S"|"1997"|"12"|"$8,000"|"no work proposed"|"1"|"S"|"1997"|"12"|"$8,000"|"No work proposed"|"0"||||"0"||"1"|"S"|"1997"|"12"|"$7,000"|"no work proposed"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"84,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|||"0"|"0"||"WARMING"||"0"|"0"|"GOOD"|"storage space is inadequate"|"$281,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/13/2010 11:32:16 AM| 214|"Salamanca City SD"|"04320005"|"Greer Building"|"3001"|"07/08/2010"|"Fern Avenue"|"Salamanca"|" 14779"|"ANNUAL"|"07/01/2011"|"1985"|"4100"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Maintenance & Grounds Building"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1985"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1985"|"5"|"35000"|"Replace existing services with new underground electrical service."|"1"|"E"|"2008"|"23"|"0"||"0"||||"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"|"E"|||"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"ASPHALT"|"E"|"2008"|"15"|"0"||"1"|"CONCRETE"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1985"|"15"|"0"||"0"||||"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1985"|"5"|"20000"|"Replace original distribution equipment and devices."|"1"|"S"|"1985"|"5"|"15000"|"Replace existing T12 Fluorescent lighting."|"1"|"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2006"|"15"|"0"||"1"|"COMMON"|"S"|"2006"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"|"No"|"0"|"0"|"0"|"S"|"1985"|"15"|"0"||"MASONRY"|"0"|"0"|"No"|"0"|"0"|"0"|"0"|"0"|"No"|"S"|"1985"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"5"|"10000"|"Replace existing overhead doors with new insulated overhead doors."|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"NA"|"1985"|"10"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"|"No"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"No"|"S"|"2002"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2006"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2006"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"10"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"2008"|"3"|"65000"|"Replace furnace serving garage and update paint storage ventilation."|"0"||||"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"6"|"0"||"0"||||"0"||"1"|"NF"|"1985"|"1"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"FAIR"||"$155,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/13/2010 11:58:05 AM| 219|"Salamanca City SD"|"04320005"|"Bus Garage"|"5004"|"07/22/2010"|"Front Avenue"|"Salamanca"|" 14779"|"ANNUAL"|"07/01/2011"|"1956"|"14475"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Maintenance / Transportation"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"1"|"1000"|"0"|"0"|"S"|"1987"|"10"|"0"||"1"|"MUN_UTILIT"|"E"|"2008"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1997"|"5"|"30000"|"Install underground electrical service."|"1"|"S"|"1987"|"15"|"0"||"0"||||"0"||"1"|"S"|"1987"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"8"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"2007"|"22"|"0"||"1"|"E"|"2007"|"22"|"0"||"1"|"E"|"2007"|"22"|"0"||"1"|"E"|"E"|"2008"|"18"|"0"||"0"||||"0"||"1"|"E"|"2008"|"28"|"0"||"1"|"1"|"S"|"2006"|"5"|"5000"|"Replace older wiring devices."|"1"|"S"|"2006"|"5"|"5000"|"Replace remaining T12 Fluorescent lighting."|"1"|"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2007"|"22"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"|"No"|"0"|"0"|"0"|"S"|"1972"|"15"|"0"||"MASONRY"|"0"|"0"|"No"|"0"|"0"|"0"|"0"|"0"|"No"|"S"|"1972"|"15"|"0"||"1"|"MASONRY"|"S"|"1956"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"1997"|"10"|"0"|"Window openings are existing glass block."|"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"No"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"No"|"S"|"1998"|"13"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1997"|"10"|"0"||"1"|"IRON"|"S"|"1997"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"E"|"2008"|"25"|"0"||"1"|"E"|"2008"|"25"|"0"||"1"|"E"|"2008"|"5"|"25000"|"Extend tailpipe exhaust and add mechanical room ventilation."|"1"|"E"|"2008"|"5"|"5000"|"Modify boiler burner controls with O.A. sensor."|"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"6"|"0"||"0"||||"0"||"1"|"S"|"2006"|"1"|"3000"|"Install LED exit signs."|"1"|"E"|"2008"|"25"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"||"0"|"1"||"FAIR"||"$73,000"|"S"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/13/2010 2:33:43 PM| 220|"West Genesee CSD"|"42010106"|"Transportation Center "|"5014"|"7/27/10"|"5203 WEST GENESEE ST "|"CAMILLUS "|" 13031"|"ANNUAL"|"9/1/11"|"2001"|"39,020"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN,OTHER"|"School Bus Maintenance"|"0"||"0"|"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"40"|"$25,000"|"no work proposed"|"1"|"MUN_UTILIT"|"S"|"2006"|"40"|"$25,000"|"no work proposed"|"1"|"S"|"1981"|"43"|"$50,000"|"no work proposed"|"1"|"UTIL"|"BELOW"|"S"|"2001"|"32"|"$258,000"|"$28,000 work proposed"|"1"|"S"|"2006"|"20"|"$150,000"|"$33,000 work proposed"|"0"||||"0"||"1"|"S"|"2006"|"20"|"$50,000"|"no work proposed"|"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1980"|"10"|"$10,000"|"no work proposed"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2006"|"20"|"$50,000"|"$4,000 work proposed"|"1"|"ASPHALT"|"S"|"2006"|"20"|"$1,200,000"|"$46,000 work proposed"|"1"|"CONCRETE"|"S"|"2001"|"10"|"$50,000"|"$25,000 work proposed"|"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"43"|"$435,000"|"$140,000 work proposed"|"1"|"S"|"1981"|"23"|"$215,000"|"$69,000 work proposed"|"1"|"S"|"2001"|"23"|"$220,000"|"$71,000 work proposed"|"1"|"S"|"2001"|"12"|"$45,000"|"no work proposed"|"0"||||"0"||"1"|"S"|"S"|"2001"|"17"|"$35,000"|"No work proposed, several 1981 remain."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"32"|"$258,000"|"$5,000 work proposed"|"1"|"S"|"2001"|"12"|"$172,000"|"no work proposed, 1981 vintage remains at storage bays"|"1"|"1"|"S"|"2001"|"12"|"$86,000"|"no work proposed"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2001"|"12"|"$24,000"|"no work proposed"|"1"|"COMMON"|"S"|"2001"|"43"|"$220,000"|"$71,000 work proposed"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"43"|"$220,000"|"$71,000 work proposed, most of building 1981 vintage."|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"43"|"$425,000"|"$140,000 work proposed, 1981 for N, S, and W sides of building."|"0"|||||"0"||"1"|"MASONRY"|"S"|"2001"|"43"|"$10,000"|"$3,000 work proposed, 1981 for N, S, and W sides of building."|"S"|"S"|"0"|"1"|"2001"|"23"|"$70,000"|"$23,000 work proposed, several 1981 remain."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"N"|"2001"|"23"|"$16,000"|"no work proposed, several 1981 remain."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"7"|"$435,000"|"$140,000 work proposed"|"0"|||||"0"||"1"|"COPPER"|"S"|"2001"|"32"|"$123,000"|"$3,000 work proposed, one toilet room is 1981 vintage."|"1"|"IRON"|"S"|"2001"|"42"|"$184,000"|"$4,000 work proposed. One toilet room is 1981 vintage."|"1"|"NAT_GAS"|"S"|"2001"|"7"|"$21,000"|"no work proposed"|"1"|"S"|"2001"|"12"|"$52,000"|"no work proposed One toilet room is 1981 vintage."|"1"|"CV"|"1"|"FURNACE"||"S"|"2001"|"22"|"$146,000"|"$3,000 work proposed"|"1"|"S"|"2001"|"42"|"$12,000"|"no work proposed"|"1"|"S"|"2001"|"22"|"$177,000"|"no work proposed All roof top units replaced."|"1"|"S"|"2001"|"22"|"$210,000"|"No work proposed Ventilating system at repair bay and toilet are 1981 vintage."|"1"|"S"|"2001"|"12"|"$70,000"|"no work proposed."|"1"|"S"|"2001"|"22"|"$126,000"|"no work proposed. Ductwork at repair bay and toilet are 1981 vintage."|"1"|"S"|"2001"|"12"|"$50,000"|"no work proposed"|"1"|"S"|"2001"|"12"|"$66,000"|"no work proposed"|"1"|"S"|"2001"|"12"|"$20,000"|"no work proposed"|"1"|"S"|"2001"|"2001"|"$280,000"|"No work proposed. Revisions to 1981 system made in 2001 for newly occupied space."|"1"|"S"|"2001"|"12"|"$43,000"|"no work proposed"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"70,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Vehicle lifts nearing end of useful life, lift and work bays maxed out, need engine block heaters."|"$1,014,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/13/2010 3:04:29 PM| 221|"North Merrick UFSD"|"28022902"|"Camp Avenue School"|"0004"|"10/08/2010"|"1712 Merrick Ave."|"North Merrick"|" 11566"|"ANNUAL"|"04/01/2010"|"1923"|"61,263"|"3"|"6"|"1"|"DISTRICT"|"INSTRUCT"||"522"|"K,1,2,3,4,5"|"0"|"1"|"1"|"522"|"0"|"0"|"OTHER"|"Corridor"|"25"|"17,875"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1990"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"7"|"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"7"|"0"||"1"|"S"|"1956"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"30"|"0"||"1"|"S"|"1956"|"8"|"0"||"0"||||"0"||"1"|"S"|"1956"|"8"|"45,000"|"Provide additional drainage along the south side & rear of building around fields & playground."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1956"|"4"|"283,000"|"Create new drop off along Merrick Ave.; replace asphalt; pave play area; address flooding."|"1"|"CONCRETE,ASPHALT"|"S"|"1956"|"3"|"87,500"|"Sidewalk replacement required-could be tied into new drop off/parking project @ Merrick Ave."|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1956"|"2"|"0"|"Y"|"Provide additional drainage at pla area; field & asphalt."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"25"|"385,000"|"Foundation treated with stucco & painted white begun to crack. Repl rotted steel lintels; replace stucco & paint"|"1"|"S"|"1956"|"25"|"0"|"Cracks noted in storage room across Rm 13; should be monitored."|"1"|"S"|"1956"|"25"|"0"|"Extensive cracking throughout interior walls. Paint could be lead base"|"1"|"S"|"1995"|"7"|"978,000"|"Original ceilings are concealed spline glued to plaster. Thought to install new acoustical ceilings below existing spline ceilings."|"0"||||"0"||"1"|"U"|"U"|"1956"|"3"|"193,000"|"Program to replace corridor doors & hardware should be considered by District."|"1"|"S"|"1956"|"25"|"265,000"|"Stairwell should be enclosed to meet current SED & building code requirements."|"0"||||"0"||"1"|"0"|"S"|"1956"|"15"|"46,000"|"Provide additional sub-panels to meet building's needs."|"1"|"S"|"1985"|"5"|"0"|"Cost to replace all pendant hunglighting is included in Q72."|"1"|"1"|"S"|"2000"|"15"|"80,000"|"recommend replacement of stage sound system."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"12"|"342,000"|"Recommend replacement of flooring in all spaces where new VCT was installed over plywood. New VCT in K rooms."|"1"|"COMMON"|"S"|"1956"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"15"|"0"||"SLABGRADE,OTHER"|"Reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"25"|"0"|"No access to see above ceilings."|"MASONRY"|"0"|"0"||"1"|"1"|"1"|"1"|"1"||"U"|"1956"|"25"|"245,000"|"Overall condition is fair to good. Should replace decorative wood columns, cornice & moldings."|"1"|"MASONRY"|"S"|"1956"|"20"|"0"||"1"|"MASONRY"|"U"|"1956"|"3"|"178,000"|"Parapets throughout building in need of immediate attention."|"S"|"U"|"0"|"1"|"2001"|"3"|"0"|"Remaining exterior doors to be replaced in spring 2011."|"1"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"0"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"12"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1956"|"7"|"0"||"1"|"IRON"|"S"|"1956"|"7"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"15"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1956"|"5"|"695,000"|"Recommend replacement of existing boilers, burners, vacuum condensate & sump pumps."|"1"|"S"|"1995"|"12"|"0"||"1"|"S"|"1995"|"7"|"0"||"1"|"S"|"1956"|"5"|"1,375,000"|"Mechanical ventilation Phase 1 to be completed summer 2011."|"1"|"S"|"1939"|"5"|"2,225,000"|"Recommend replacementof all existing piping; convert from steam to hot water system."|"1"|"S"|"1956"|"8"|"0"||"1"|"S"|"1956"|"4"|"165,000"|"Recommend complete building-wide pneumatic system upgrade. Not required if UV's are replaced."|"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"S"|"1956"|"1956"|"0"|"Inspected 2010-work on Kitchen hood scheduled for summer 2011."|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"|"0"|"410,000"|"Convert multi-stall & single stall toilets to ADA"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"FAIR"||"8,907,500.00"|"U"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/13/2010 3:37:14 PM| 223|"Spencerport CSD"|"26100106"|"High School"|"0008"|"04/19/2010"|"2707 SPENCERPORT RD "|"SPENCERPORT "|" 14559"|"ANNUAL"|"09/11/2011"|"1969"|"277,241"|"2"|"13"|"0"|"DISTRICT"|"INSTRUCT"||"1500"|"9,10,11,12"|"0"|"1"|"1"|"1500"|"0"|"0"|||"99"|"85,437"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1975"|"8"|"0"|"Simplex #SKS-30 3 gpm transfer pump"|"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"1"|"S"|"2002"|"7"|"0"|"6" service, 3" meter. Rooftop gas piping to be reviewed in 7 years."|"1"|"UTIL"|"BELOW"|"S"|"2003"|"50"|"0"|"Underground primary feeds utility transformer in vault."|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"50"|"0"||"1"|"S"|"2003"|"10"|"1,405"|"Lower catch basins for waterflow."|"1"|"S"|"2003"|"25"|"0"||"1"|"MUNI"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"0"||||||"1"|"ASPHALT"|"U"|"2003"|"3"|"931,296"|"Milling and resurfacing partial reconstruction and sealing."|"1"|"CONCRETE,ASPHALT"|"U"|"2002"|"2"|"73,036"|"Concrete sidewalk replacement. Seal asphalt walks."|"0"||||||"1"|"S"|"2009"|"10"|"9,505"|"Y"|"Install underpin at tennis courts to relieve heaving."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1969"|"30"|"5,954."|"Repair spalled and heaved slabs north entrance."|"1"|"S"|"2003"|"50"|"7,763."|"Replace broken CMU and seal vertical cracks."|"1"|"S"|"2003"|"20"|"39,818"|"Replace broken CMU and seal vertical cracks."|"1"|"S"|"2003"|"20"|"462,224"|"Replace stained ceiling tile in corridors and library."|"1"|"S"|"2009"|"20"|"0"|"Current project repairs/replaces lockers."|"1"|"S"|"S"|"2003"|"15"|"160,718"|"ADA hardware needed."|"1"|"S"|"2003"|"58"|"0"||"1"|"S"|"1969"|"15"|"0"|"New hydraulic piston scheduled to be installed in 2011."|"1"|"1"|"S"|"2003"|"37"|"0"||"1"|"S"|"2007"|"15"|"0"|"Units observed appear to be well maintained and in good working order."|"1"|"1"|"U"|"2001"|"10"|"65,584"|"500-Wing cannot be heard although they can hear the office verbalizations."|"1"|"S"|"2003"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"18"|"1,148,921"|"Replacement of VAT flooring."|"1"|"COMMON"|"S"|"2003"|"25"|"79,542"|"Replace and remediate areas of severe settlement cracks."|"1"|"INSTRUCT"|"S"|"2003"|"30"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1969"|"30"|"25,516"|"Provide expansion joint cover @ rooms 405 & 421."|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1969"|"30"|"129,593"|"Repair spalding exterior concrete wall panels."|"1"|"MASONRY,METAL"|"S"|"1969"|"10"|"0"||"1"|"MASONRY,METAL"|"S"|"2003"|"20"|"2,600"|"Recaulk parapet caps."|"S"|"S"|"0"|"1"|"2003"|"8"|"116,627"|"Due to de-icing product, hollow metal and aluminum frames are deteriorating."|"1"|"S"|"2003"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"5"|"389,448"|"Repair single glazed windows with insulated units."|"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"1"|"0"|"1"|"1"|"1"||"S"|"2003"|"3"|"3,871,237"|"Portions of the roof are nearing the end of their life and need to be replaced."|"1"|"PLASTIC"|"S"|"1997"|"10"|"0"||"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"20"|"0"|"Aerco KC1000 heater 2 storage tanks Heater set at 140 degrees. 110 degree loop to lavatories 140 degree loop to kitchen."|"1"|"S"|"2009"|"4"|"24,300"|"Drinking fountain/water coolers are original. - Replace."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"2"|"215,325"|"Replace main office and library units."|"1"|"S"|"2003"|"3"|"50,369"|"Provide ventilation in various locations and dust collection at Room 316."|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"|"Simplex 41000 controller in place. Appears relatively new and is in good working order."|"1"|"S"|"2003"|"15"|"0"|"All areas required to have detection devices appear to have them in place."|"1"|"S"|"2003"|"2003"|"0"|"Ansul system at kitchen hood"|"1"|"S"|"2007"|"15"|"0"|"Energy savings could be realized by replacing old units with LED versions."|"1"|"S"|"2003"|"3"|"46,575"|"Replacement of emergency generator only. Structure contains both 20 KW emergency generator and 150 KW standby generator."|"1"|"1"||"Door hardware to be upgraded to lever sets."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"|"All units observed appeared to be in good working order."|"1"|"0"|"0"|"1"|"0"||"1"|"CLASSROOMS,HALLWAYS,OTHER"|"Library and Storage"|"0"|||"1"|"1"|"2,103,536"|"Replace stained ceilings."|"1"|"1"|"1"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"GOOD"|"F. Filters observed to be clean. G. Ventilation confirmed to each space."|"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"1"|"COMMSYS,HVAC,FIREALARM,SUMPPUMP,SCURITYSYS"|"FULL"|"0"|"1"||"GOOD"||"13,152,316"|"U"|"1"|"LaBella Associates, P.C."|"300 State Street, Rochester, NY 14614"|"585-454-6110"|"mshort@labellapc.com"|"Michael E. Short"|"032717"|"I ACCEPT"|12/13/2010 4:08:07 PM| 224|"Falconer CSD"|"06110104"|"Jr / Sr High Scool"|"0001"|"08/31/2010"|"2 East Ave. North"|"Falconer"|" 14733"|"ANNUAL"|"08/01/2011"|"1930"|"231,105"|"3"|"9"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"|"Athletics and Extracurricular"|"700"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"700"|"0"|"0"|||"33"|"26,400"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP,OTHER"|"Distance Learning"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"10"|"100,000"|"Needs sealing, restriping and some reconstruction around catch basins."|"1"|"CONCRETE"|"S"|"2000"|"10"|"10,000"|"Sidewak repairs are needed(cracking, heaving, caulking, etc.)"|"0"||||"0"||"1"|"S"|"2005"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"22,000"|"Replace 1967 corridor wall tile"|"1"|"S"|"2000"|"5"|"100,000"|"Ceilings in corridors and classrooms of 1967 wing are old, aged, very dirty, grid rusting and should be repaired."|"1"|"S"|"2000"|"10"|"0"|"Locker room lockers are showing signs of abuse"|"1"|"S"|"S"|"2006"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"5"|"25,000"|"Part of the cafeteria, the upper floor Biology classroom, lower level corridor and Print Shop all have old T-12 lamps. These should be upgraded to T-8 for energy conservation."|"1"|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"2"|"25,000"|"Change out carpet in 1996 wing"|"1"|"INSTRUCT,COMMON"|"S"|"2006"|"15"|"235,000"|"Replace vinyl stair treads/repalce remaining asbestos floor tile"|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"140,000"|"Terrazzo corridors cracking, should be replaced"|"1"|"INSTRUCT"|"S"|"2000"|"5"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Cast-in-place concrete joints"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"1"|"1"|"0"||"S"|"2000"|"3"|"150,000"|"All mortared joints in pre-cast concrete panels need joints cut out and repointed. All stone joints on the 1996 wing and south elevation (stair, ramp, planter feature) need to be cut and re-mortared."|"1"|"MASONRY"|"S"|"2005"|"10"|"0"||"1"|"MASONRY"|"S"|"2005"|"10"|"0"||"S"|"S"|"1"|"1"|"2005"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"10"|"0"||"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"10"|"0"||"1"|"GLASS"|"S"|"2005"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1996"|"12"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1996"|"12"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"4"|"45,000"|"PVI water heaters were installed in 1996. Replacement with high efficiency heaters is recommended. "|"1"|"S"|"1996"|"4"|"22,000"|"Replace flush valves and seats"|"0"||"1"|"BOILERWATE"||"S"|"1996"|"5"|"350,000"|"Both boilers and select unit ventilators need to be replaced."|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"8"|"0"||"1"|"S"|"1967"|"4"|"40,000"|"Replace roof exhaust fans in 1967 wing "|"1"|"S"|"1996"|"5"|"60,000"|"Corridor convectors, fin radiation and cabinet unit heaters need to be upgraded and replaced."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2006"|"4"|"135,000"|"A large amount of controls in southwest portion of the building are still pneumatic. These control valves and all wiring should be upgraded. "|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2001"|"5"|"3,000"|"Select exit sign upgrade to LED"|"1"|"S"|"2001"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"|"Part of the cafeteria, the upper floor Biology classroom, lower level corridor and Print Shop all have old T-12 lamps. These should be upgraded to T-8 for energy conservation."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"1"|"1"|"0"|"0"||||"1"||"GOOD"||"1,112,000.00"|"S"|"0"|"Harrington Sandberg Architecture and Engineering, P.C."|"500 E. Sixth St., Jamestown, NY 14701"|"716-483-3153"|"mb@harringtonsandberg.com"|"Ronald I. Kessler, R.A."|"023043"|"I ACCEPT"|12/13/2010 4:19:00 PM| 225|"Caledonia-Mumford CSD"|"24020104"|"District Office"|"5002"|"05/24/2010"|"99 North St"|"Caledonia"|" 14423"|"ANNUAL"|"08/01/2011"|"1957"|"5565"|"1"|"10"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Maintenance/Storage"|"0"|||"0"|"0"||||||"0"|"0"|"ADMIN,OTHER"|"Maintenance/Storage"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"10"|"0"||"1"|"SITESEPT"|"S"|"1998"|"10"|"0"|"Septic System remains in satisfactory condition."|"1"|"E"|"1998"|"10"|"0"||"0"|"UTIL"|"ABOVE"|"E"|"1998"|"10"|"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"20"|"0"|"Drives are in satisfactory condition, parking lots require some curbing and asphalt patching - estimated $5000 for repairs."|"1"|"CONCRETE"|"S"|"1998"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1998"|"3"|"$2500"|"We recommend that the distribution panel be replaced. It is currently at capacity."|"1"|"S"|"1998"|"3"|"$3200"|"we recommend the install ation of some exterior lights, occupancy sesors and emergency light at exterior doors."|"1"|"1"|"S"|"2008"|"8"|"0"||"0"||||"0"||"0"|"COMMON"|"S"|"1998"|"10"|"0"||"1"|"COMMON"|"S"|"1998"|"6"|"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"|"Maintenance/Storage has concrete floor."|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1957"|"10"|"0"||"1"|"MASONRY"|"S"|"1957"|"10"|"0"|"The top of the chimney is beginning to tip. It is recommended that it be stabilized with a metal corset, or reconstructed to prevent it from toppling. Estimated repair - $1500."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"10"|"0"|"Exterior Door 17 with transom is in poor condition and should be replaced. Estimated repair - $2300."|"1"|"S"|"1998"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"10"|"0"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"0"||"S"|"1993"|"5"|"0"|"There is no counter-flashing where the lower roof abuts the raised portion of the roof. Counter-flashing should be provided to avoid water leaking at the roof flashing."|"0"|||||"0"||"1"|"COPPER"|"S"|"1998"|"10"|"0"||"1"|"IRON"|"S"|"1998"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"E"|"1998"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"8"|"0"|"We recommend the addition of some emergency exit lights to bring the building up to current standards. Estimated cost - $750."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"FL_ FULL,NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"$71,770"|"S"|"1"|"Hunt Engineers, Architects, Land Surveyors, P.C."|"4 Commercial Dr. suite 300, Rochester, NY 14614"|"585-327-7950"|"cakej@hunt-eas.com"|"John Cake, AIA"|"013885"|"I ACCEPT"|12/13/2010 4:20:08 PM| 226|"North Merrick UFSD"|"28022902"|"Harold D. Fayette Elementary"|"0001"|"09/22/2010"|"1057 Merrick Ave"|"North Merrick"|" 11566"|"ANNUAL"|"04/01/2010"|"1950"|"50,327"|"3"|"6"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"300"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"300"|"0"|"0"|||"17"|"14,400"|"ADMIN,ART,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1990"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"7"|"0"||"1"|"MUN_UTILIT"|"S"|"1975"|"10"|"0"||"1"|"S"|"1950"|"10"|"0"|"Gas to burner pilot lites & Kitchen equipment"|"1"|"UTIL"|"BELOW"|"S"|"2003"|"30"|"0"||"1"|"S"|"2005"|"15"|"5,000"|"Address flooding issues outside S/E wing (Rm 9/10. Clean out drain in open vault at transformer vault."|"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"12"|"164,500"|"Recommend repaving asphalt play area. Also address flooding issues"|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"3"|"0"|"Concrete replacement to take place summer 2011."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"25"|"0"||"1"|"S"|"1950"|"25"|"0"||"1"|"S"|"1950"|"25"|"131,000"|"Cracks in Stage & Kitchen to be addressed; temporary repairs were made to cracks at Stage."|"1"|"S"|"2005"|"15"|"692,000"|"Thought should be given to start long-term replacement program to replace concealed spline ceilings w/2x2 dropped ceilings."|"0"||||"0"||"1"|"S"|"S"|"1950"|"5"|"187,000"|"Program to replace corridor doors & hardware should be considered by District."|"1"|"S"|"1950"|"25"|"46,000"|"Enclose both stair towers @ 2nd floor w/45 minute rated smoke doors, frams & sheetrock enclosures."|"0"||||"0"||"1"|"0"|"S"|"2000"|"15"|"40,000"|"Provide additional sub panels to meet buildings's needs."|"1"|"S"|"1995"|"10"|"81,000"|"Recommend replacement of corridor & teaching space corridors throughtout building w/energy efficient lighting & occupancy sensors."|"1"|"1"|"S"|"2000"|"15"|"0"|"telephone system recently replaced."|"0"||||"0"||"1"|"COMMON"|"S"|"2006"|"8"|"0"||"1"|"INSTRUCT"|"S"|"1989"|"5"|"330,000"|"Recommend replacement of corridor & classroom VAT w/VCT"|"1"|"COMMON"|"S"|"1950"|"25"|"0"||"1"|"INSTRUCT"|"S"|"1950"|"12"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"25"|"0"|"No access to see above ceiling."|"MASONRY"|"0"|"0"||"1"|"1"|"1"|"1"|"0"||"U"|"2005"|"3"|"470,000"|"Extensive cracking throughout building. Windows need to be reflashed."|"1"|"MASONRY"|"S"|"1950"|"10"|"5,000"|"Repointing required."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2006"|"2"|"0"|"remaining exterior doors to be replaced summer 2011."|"1"|"S"|"1950"|"15"|"0"|"repointing of landings to take place summer 2011."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1950"|"2"|"870,000"|"Replace all original windows w/new single glazed dual sash horiontal sliding windows, low e-glazing, insect screens & new window treatment."|"CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"0"|"1"||"S"|"1999"|"10"|"0"||"1"|"GLASS"|"U"|"1999"|"10"|"45,000"|"Recommend replacement of (3) lg skylights, including interior glass block skylights; repair plaster at skylight wells."|"1"|"COPPER"|"S"|"1950"|"10"|"0"||"1"|"IRON"|"S"|"1950"|"10"|"0"||"1"|"OIL"|"S"|"1950"|"3"|"38,000"|"Pony boiler provides hot water; recommend replacement of system w/new oil fired hot water heater."|"1"|"S"|"1950"|"8"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1950"|"5"|"625,000"|"Recommend replacement of existing boilers, burners & condensate tank."|"1"|"S"|"1950"|"5"|"0"||"1"|"S"|"2004"|"10"|"0"|"Window A/C units."|"1"|"S"|"1950"|"5"|"790,000"|"Replace (32) UV's & (1) H&V unit."|"1"|"S"|"1950"|"5"|"350,000"|"Remove asbestos in crawl space & replace seam traps; reinsulate piping."|"1"|"S"|"1950"|"7"|"0"||"1"|"S"|"1950"|"5"|"105,000"|"Recommend complete building wide pneumatic system upgrade"|"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"U"|"1950"|"1950"|"0"|"Kitchen hood replacement scheduled for summer 2011."|"1"|"S"|"1995"|"8"|"0"||"0"||||"0"||"1"|"0"|"270,000"|"Convert multi-stall toilets to ADA."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"FAIR"||"5,244,500.00"|"U"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/13/2010 4:32:48 PM| 227|"West Genesee CSD"|"42010106"|"West Genesee High School "|"0007"|"7/27/10"|"5201 WEST GENESEE ST "|"CAMILLUS "|" 13031-2299"|"ANNUAL"|"9/1/2011"|"1953"|"311,854"|"2"|"18"|"0"|"DISTRICT"|"INSTRUCT"||"1647"|"9,10,11,12"|"0"|"1"|"0"|"1647"|"0"|"0"|||"95"|"123,948"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,SCIENCELAB,SPECED,POOL,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2005"|"50"|"$269,000"|"no work proposed"|"1"|"MUN_UTILIT"|"E"|"2005"|"50"|"$699,000"|"no work proposed"|"1"|"E"|"2002"|"15"|"$70,000"|"no work proposed"|"1"|"UTIL"|"BELOW"|"S"|"2002"|"15"|"$539,000"|"no work proposed"|"1"|"E"|"2005"|"50"|"$807,000"|"$8,000 work proposed"|"1"|"S"|"2002"|"15"|"$10,000"|"$8,000 work proposed"|"1"|"S"|"2002"|"15"|"$100,000"|"$50,000 work proposed"|"0"||||"0"||"1"|"MUNI,ONSITE"||"1"|"S"|"2002"|"15"|"$10,000"|"no work proposed"|"1"|"S"|"2005"|"30"|"$25,000"|" no work proposed"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"$50,000"|"no work proposed"|"1"|"ASPHALT"|"E"|"2005"|"20"|"$484,000"|"$125,000 work provided"|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"20"|"$188,000"|"$93,000 work proposed"|"0"||||"0"||"1"|"E"|"2005"|"20"|"$700,000"|"Y"|"$747,000 work propsed"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1953"|"15"|"$12,927,000"|"No work proposed"|"1"|"S"|"1954"|"15"|"$485,000"|"no work proposed"|"1"|"S"|"2002"|"20"|"$808,000"|"$168,000 work proposed"|"1"|"S"|"2002"|"10"|"$840,000"|"$340,000 work proposed"|"1"|"E"|"2004"|"15"|"$205,000"|"$75,000 work proposed"|"1"|"S"|"S"|"2004"|"15"|"$242,000"|"$60,000 work proposed"|"1"|"S"|"2004"|"20"|"$156,000"|"$17,000 work proposed"|"1"|"S"|"2004"|"10"|"$199,000"|"$104,000 work proposed"|"1"|"1"|"S"|"2004"|"20"|"$3,020,000"|"$20,000 work proposed"|"1"|"S"|"2004"|"10"|"$2,050,000"|"$20,000 work proposed"|"1"|"1"|"S"|"2004"|"10"|"$504,000"|"$170,000 work proposed"|"1"|"S"|"1963"|"15"|"$667,000"|"$63,000 work proposed"|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"$11,000"|"no work proposed"|"1"|"INSTRUCT"|"S"|"2002"|"25"|"$127,000"|"no work proposed"|"1"|"COMMON"|"S"|"2002"|"25"|"$42,000"|"$160,000 work proposed"|"1"|"INSTRUCT"|"S"|"2002"|"10"|"$20,000"|"no work proposed"|"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1954"|"20"|"$2,500,000"|"$600,000 work proposed"|"STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"$4,040,000"|"no work proposed"|"1"|"MASONRY"|"S"|"1953"|"15"|"$199,000"|"no work proposed"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"$145,000"|"$23,000 work proposed"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"5"|"$377,000"|"no work proposed Some 1986 vintage remain"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"remove or reconfigure ceilings to expose skylights"|"E"|"2005"|"25"|"$2,690,000"|"$50,000 work proposed"|"1"|"PLASTIC"|"S"|"2005"|"25"|"$2,690,000"|"$50,000 work proposed"|"1"|"COPPER"|"S"|"2004"|"15"|"$1,036,000"|"$44,000 work proposed. Some 1953 and 1963 vintage remains."|"1"|"IRON"|"S"|"2004"|"20"|"$1,404,000"|"$6,000 work proposed. Some 1953 and 1963 vintage remains."|"1"|"NAT_GAS"|"S"|"2008"|"15"|"$86,000"|"no work proposed. Domestic hot water heater and pool boiler replaced in 2008"|"1"|"S"|"2004"|"5"|"$389,000"|"$107,000 work proposed. Some 1963 vintage remain."|"1"|"DD_MZ"|"1"|"BOILERSTEA"||"S"|"1986"|"10"|"$269,000"|"$400,000 work proposed."|"1"|"S"|"2004"|"45"|"$216,000"|"no work proposed"|"1"|"S"|"2004"|"15"|"$409,000"|"$80,000 work proposed"|"1"|"S"|"2004"|"15"|"$1,400,000"|"$163,000 work proposed. Some 1953 and 1963 vintage remains."|"1"|"S"|"2004"|"15"|"$1,056,000"|"$7,000 work proposed. Some 1953 and 1963 vintage remains."|"1"|"S"|"2004"|"15"|"$3,663,000"|"$20,000 work proposed"|"1"|"S"|"2004"|"10"|"$426,000"|"$5,000 work proposed."|"1"|"S"|"2002"|"10"|"$458,000"|"$5,000 work proposed"|"1"|"S"|"2002"|"20"|"$733,000"|"$5,000 work proposed"|"1"|"S"|"2002"|"2002"|"$54,000"|"$25,000 work proposed"|"1"|"S"|"2002"|"15"|"$431,000"|"$3,000 work proposed"|"0"||||"0"|"$320,000 work proposed"|"1"|"1"||"$8,000 ADA signage work proposed"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"5,458,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"1"|"0"||"FULL"||"1"||"GOOD"|"Inadequate storage space."|"$5,088,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/13/2010 4:35:16 PM| 228|"Weedsport CSD"|"05030104"|"Elementary School"|"0001"|"08/03/2010"|"8954 Jackson Street"|"Weedsport"|" 13166"|"ANNUAL"|"09/01/2011"|"1908"|"54452"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"458"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"458"|"0"|"0"|||"36"|"33680"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2005"|"20"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"15"|"0"|"Some checking at joints."|"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"|"Maintain fall value on depth of mulch."|"1"|"S"|"2008"|"12"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2004"|"25"|"105000"|"Water penetration in basement (1908 wing)"|"1"|"S"|"2004"|"30"|"10000"|"Recommend additional firestopping in Boiler Room."|"1"|"S"|"2004"|"30"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"5"|"88000"|"Lockers in 1938 wing are original and nearing end of useful life."|"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"11000"|"Recommend replacing select terrazzo stair treads in 1908 wing."|"1"|"S"|"1991"|"20"|"0"||"1"|"1"|"S"|"2004"|"35"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1938"|"15"|"0"||"CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"30"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"2004"|"25"|"48000"|"Repoint portions of 1908, 1935 and 1938 wings."|"1"|"MASONRY"|"S"|"1938"|"20"|"0"||"1"|"MASONRY"|"S"|"2004"|"20"|"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"13000"|"Recommend replacing 4 exterior doors."|"1"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOOD"|"U"|"Y"|"1996"|"5"|"280000"|"Recommend replacement of single glazed windows."|"CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"1"|"PLASTIC"|"E"|"2010"|"20"|"0"||"1"|"COPPER"|"S"|"2004"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"15"|"26000"|"Replace kitchen grease trap and Boiler Room sump pump."|"1"|"NAT_GAS"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"15"|"158000"|"Replace original (1930's) fixtures."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1999"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"|"Split DX units."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"5"|"105000"|"Replace control system."|"1"|"S"|"2004"|"5"|"157000"|"Existing Simplex 4002. Replace with point addressable system and add classroom strobes."|"1"|"S"|"2004"|"5"|"35000"|"Replace all detectors with point addressable type."|"1"|"S"|"2004"|"2004"|"0"|"Ansul system on kitchen hood."|"1"|"S"|"2004"|"5"|"0"|"Maintenance cost - replace battery packs in corridors."|"0"||||"0"||"1"|"1"|"1512000"|"Recommend renovating OT/PT, remaining Toilet Rooms, and Nurse's Office Toilet Room to improve accessibility."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"INACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2548000"|"S"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/14/2010 8:31:49 AM| 230|"Commack USFD"|"58041003"|"OLD FARMS ELEMENTARY SCHOOL"|"0006"|"04/05/2010"|"CALVERT AVE "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1963"|"37884"|"1"|"2"|"1"|"LSD_NDE"|"INSTRUCT,OTHER_ORG"||"205"|"Pre-K,K"|"0"|"1"|"0"|"205"|"0"|"0"|||"10"|"8300"|"ADMIN,CAFE,GYM,PREK"||"1"|"0"|"0"|"1"|"10000"|"E"|"2009"|"30"|"0"|"New old tank was installed."|"1"|"MUN_UTILIT"|"S"|"2009"|"30"|"0"|"Back flow preventer was installed."|"1"|"SITESEPT"|"S"|"1963"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1963"|"5"|"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||"1963"|"15"|"0"||"1"|"ASPHALT"|"S"|"2004"|"19"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"S"|"1963"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"15"|"0"||"1"|"S"|"1963"|"15"|"0"||"1"|"S"|"1963"|"15"|"0"||"1"|"U"|"1963"|"1"|"100000"|"Installnew new suspended drop-in tile ceilings or provide access panels for easy inspection of roof structural condition. "|"1"|"S"|"1963"|"5"|"0"||"1"|"U"|"U"|"1963"|"1"|"120000"|"Replace original doors."|"0"||||"0"||"0"|"S"|||||"1"|"1"|"S"|"1963"|"5"|"0"||"1"|"U"|"1963"|"1"|"90000"|"Fixtures shall be replaced with ceiling."|"1"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"|"INSTRUCT,COMMON"|"S"|"1963"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1963"|"5"|"0"||"1"|"COMMON"|"S"|"1963"|"5"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"U"|"1963"|"1"|"15000"|"Repoint brick in some areas and replace expansion joints."|"1"|"MASONRY"|"U"|"1963"|"1"|"20000"|"Needs repointing."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1963"|"1"|"85000"|"Replace with FRP type doors."|"1"|"S"|"1963"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1963"|"1"|"280000"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"U"|"1998"|"1"|"10000"|"Clean or replace roof drains as required."|"1"|"GLASS"|"S"|"1963"|"5"|"0"||"1"|"COPPER"|"S"|"1963"|"5"|"0"||"1"|"IRON"|"S"|"1963"|"5"|"0"||"0"|"NA"||||"0"||"1"|"S"|"2008"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"31"|"0"||"1"|"S"|"2002"|"41"|"0"||"0"||||"0"||"1"|"S"|"1963"|"5"|"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"U"|"1963"|"1"|"60000"|"Perform full pneumtic controls rehab."|"1"|"U"|"1963"|"1"|"75000"|"Replace with ADA compliant system."|"1"|"U"|"1963"|"1"|"20000"|"Replace inadecuate system."|"0"||||"0"||"1"|"S"|"2008"|"5"|"0"|"Some emergency lights were replaced."|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 765,000"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/14/2010 9:53:05 AM| 234|"North Merrick UFSD"|"28022902"|"Old Mill Road School"|"0002"|"09/22/2010"|"1775 Old Mill Road"|"North Merrick"|" 11566"|"ANNUAL"|"04/01/2010"|"1950"|"43,691"|"1"|"5"|"1"|"DISTRICT"|"INSTRUCT"||"486"|"K,1,2,3,4,5,6"|"0"|"0"|"0"|"486"|"0"|"0"|"OTHER"|"Converted Toilet-OT/PT"|"23"|"18,400"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1990"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"8"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"8"|"0"||"1"|"S"|"1950"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"35"|"0"||"1"|"S"|"1950"|"15"|"0"||"0"||||"0"||"1"|"S"|"1950"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1950"|"3"|"392,000"|"Repave main parking lot & bus loop"|"1"|"CONCRETE,ASPHALT"|"S"|"1950"|"5"|"0"|"Sidewalk replacement scheduled for summer 2011"|"1"|"E"|"2006"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"|"N"|"Address flooding issues as part of storm drainage upgrade."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"25"|"0"||"1"|"S"|"1950"|"25"|"0"||"1"|"S"|"1950"|"25"|"0"|"Numerous non-structural cracks throughout the building. Cracks should be monitored by District staff."|"1"|"S"|"1950"|"12"|"541,000"|"Recommend install new 2x2 ceiling tile, grid, & new T8 fluorescent lighting & occupancy sensors."|"0"||||"0"||"1"|"S"|"S"|"1950"|"5"|"173,000"|"Recommend replacing interior doors with new "B" label doors & hardware."|"1"|"S"|"1950"|"25"|"0"||"0"||||"0"||"1"|"1"|"S"|"1950"|"5"|"37,000"|"Provide additional sub-panels to address building's needs."|"1"|"S"|"1995"|"8"|"35,000"|"Relace existing lighting & remaining incandecent lighting not indicated in Q72."|"1"|"1"|"S"|"2003"|"12"|"0"|"telephone system recently replaced."|"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"8"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"362,000"|"Formulate a long range program to remove & replace all VAT & original VAT over VCT."|"1"|"COMMON"|"S"|"1950"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1950"|"12"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"U"|"2007"|"25"|"37,000"|"Masonry repairs & UV grill replacement in Kitchen, windows, outside Gym, outside Room 24."|"1"|"MASONRY"|"S"|"2007"|"25"|"12,000"|"Chimney at Boiler Room 2 in need of replacement. Chimney at Boiler Room 1 was reconstructed in 2007."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1950"|"3"|"0"|"Doors & hardware to be replaced spring 2011."|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"Y"|"1950"|"3"|"844,000"|"Replace all original windows w/new single glazed dual sash horizontal sliding windows."|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"18"|"0"||"1"|"PLASTIC"|"E"|"2007"|"18"|"0"||"1"|"COPPER"|"S"|"1950"|"8"|"0"||"1"|"IRON"|"S"|"1950"|"8"|"0"||"1"|"OIL"|"S"|"1993"|"2"|"30,000"|"Boiler Room 1 - Hot water heater 1985"|"1"|"S"|"1950"|"8"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1950"|"3"|"765,000"|"Replace boilers, burners & condensate tanks in both boiler rooms."|"1"|"S"|"1950"|"3"|"30,000"|"Replace fuel oil loop in Boiler Room 2"|"1"|"S"|"2005"|"10"|"0"|"Window A/C units."|"1"|"S"|"1950"|"5"|"1,065,000"|"Mechanical ventilation to be completed summer 2011."|"1"|"S"|"1950"|"7"|"425,000"|"Remove asbestos in crawl space & replace steam traps; reinsulate piping."|"1"|"S"|"2007"|"12"|"0"|"All rooftop ductwork reinsulated."|"1"|"S"|"1950"|"6"|"85,000"|"Recommend complete building-wide pneumatic system upgrade"|"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"U"|"1950"|"1950"|"0"|"Project at SED awaiting approval."|"1"|"S"|"1995"|"8"|"0"||"0"||||"0"||"1"|"1"|"195,000"|"Recommend complete renovation of (1) toilet & Nurse's toilet to ADA."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"1"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"FAIR"||"5,038,000"|"U"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/14/2010 11:15:57 AM| 235|"Southern Cayuga CSD"|"05070104"|"Planetarium"|"0005"|"8/20/10"|"2384 Route 34B"|"Poplar Ridge"|" 13139"|"ANNUAL"|"10/1/10"|"1969"|"5700"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Board of Education Meeting"|"0"|"UNGRD"|"0"|"0"|"0"||||||"1"|"1950"|"SCIENCELAB,OTHER"|"Planetarium"|"0"||||||||"0"||"1"|"WELL"|"S"|"1993"|"10"|"0"|"Refer to Jr./Sr. High School survey - fed from H.S."|"1"|"SITESEPT"|"S"|"1997"|"10"|"0"|"Gravity feed to H.S. septic"|"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1995"|"15"|"0"|"Refer to Jr./Sr. High School survey - fed from H.S."|"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"15"|"0"||"1"|"CONCRETE"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1969"|"20"|"0"||"1"|"S"|"1969"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"Note: Some plaster has been identified as Asbestos Containing (ACM). "|"1"|"U"|"2000"|"5"|"20000"|"Clean and paint Planetarium ceiling; replace classroom ceiling"|"0"||||"0"||"1"|"S"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1969"|"5"|"70000"|"Recommend replacing transformer, MDP & BC panels."|"1"|"S"|"1995"|"10"|"0"||"1"|"1"|"S"|"2008"|"15"|"0"|"IP phone system installed w/ EXCEL funds."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1969"|"5"|"10000"|"Recommend replacing carpet @ planetarium."|"1"|"INSTRUCT"|"U"|"1969"|"5"|"17000"|"Abate/replace vinyl asbestos tile (VAT)."|"1"|"COMMON"|"S"|"1999"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1969"|"20"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"U"|"1969"|"5"|"21000"|"Brick re-pointing; replace damaged pre-cast panels & lintels above windows."|"1"|"METAL"|"S"|"2008"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"1986"|"5"|"130000"|"Replace existing roof and add roof drains as req'd."|"0"|||||"0"||"1"|"COPPER"|"S"|"2000"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2000"|"5"|"0"||"1"|"ELECTRIC,OTHER"|"U"|"1986"|"5"|"3000"|"Recommend replacing unit & relocate new to office closet. "|"1"|"S"|"2000"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2003"|"15"|"0"|"208 MBH boiler installed new."|"1"|"S"|"1969"|"10"|"0"|"Oil piping/valves fed from H.S."|"1"|"S"|"2000"|"10"|"0"|"RTU w/ DX for classroom."|"1"|"U"|"1969"|"5"|"60000"|"Recommend replacing existing unit & increase ventilation for Planetarium."|"1"|"U"|"1969"|"5"|"50000"|"Recommend replacing circ pumps, misc piping, fittings, and valves."|"1"|"S"|"1969"|"10"|"0"|"Clean ductwork"|"1"|"U"|"1969"|"5"|"26000"|"Recommend replacing controls in boiler rm and Planetarium mech rm."|"1"|"S"|"2000"|"10"|"0"|"Fed from H.S."|"1"|"S"|"2000"|"10"|"0"|"Fed from H.S."|"0"||||"0"||"1"|"S"|"2000"|"25"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"GOOD"||"407000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/14/2010 11:19:16 AM| 236|"West Genesee CSD"|"42010106"|"East Hill Elementary "|"0002"|"7/27/10"|"401 BLACKMORE RD "|"CAMILLUS "|" 13031-2199"|"ANNUAL"|"9/1/2011"|"1956"|"46,772"|"1"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"465"|"K,1,2,3,4,5"|"0"|"0"|"0"|"465"|"0"|"0"|||"28"|"24,726"|"ADMIN,GYM,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"35"|"$100,000"|"no work proposed"|"1"|"MUN_UTILIT"|"S"|"1956"|"35"|"$100,000"|"no work proposed"|"1"|"S"|"1956"|"35"|"$80,000"|"no work proposed"|"1"|"UTIL"|"BELOW"|"S"|"1956"|"35"|"$52,000"|"no work proposed"|"1"|"S"|"2003"|"40"|"$52,000"|"no work proposed"|"1"|"S"|"1956"|"40"|"$10,000"|"no work proposed"|"1"|"U"|"1956"|"5"|"$25,000"|"$25,000 work proposed"|"0"||||"0"||"1"|"MUNI,ONSITE"||"1"|"S"|"2003"|"20"|"$10,000"|"$5,000 work proposed"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"15"|"$120,000"|"$60,000 work proposed"|"1"|"CONCRETE"|"S"|"2004"|"15"|"$18,000"|"$38,000 work proposed"|"1"|"S"|"1992"|"5"|"$300,000"|"$420,000 work proposed"|"1"|"S"|"1956"|"15"|"$50,000"|"N"|"$60,000 work proposed"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"30"|"$318,000"|"$443,000 work proposed"|"1"|"S"|"1956"|"20"|"$81,000"|"no work proposed"|"1"|"S"|"1991"|"20"|"$106,000"|"$587,000 work proposed"|"1"|"S"|"1991"|"20"|"$170,000"|"$210,000 work proposed"|"1"|"S"|"1991"|"10"|"$97,000"|"$8,000 work proposed"|"1"|"S"|"S"|"1956"|"5"|"$81,000"|"$87,000 work proposed"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1991"|"35"|"$88,000"|"$134,000 work proposed"|"1"|"S"|"2009"|"20"|"$20,000"|"$104,000 work proposed"|"1"|"1"|"S"|"1991"|"15"|"$45,000"|"$45,000 work proposed"|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"10"|"$11,000"|"$182,000 work proposed"|"1"|"INSTRUCT"|"S"|"1991"|"15"|"$135,000"|"$134,000 work proposed"|"1"|"COMMON"|"S"|"1993"|"20"|"$34,000"|"$44,000 work proposed"|"1"|"INSTRUCT"|"S"|"1993"|"20"|"$3,000"|"no work proposed"|"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"25"|"$269,000"|"$442,000 work proposed"|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1956"|"15"|"$181,000"|"$510,000 work proposed"|"1"|"MASONRY"|"S"|"1956"|"10"|"$24,000"|"no work proposed"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1986"|"10"|"$106,000"|"$69,000 work proposed"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1991"|"15"|"$285,000"|"$221,000 work proposed"|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2004"|"15"|"$436,000"|"$221,000 work proposed"|"0"|||||"0"||"1"|"COPPER"|"S"|"1956"|"20"|"$39,000"|"$35,000 work proposed"|"1"|"IRON"|"S"|"1956"|"20"|"$45,000"|"$35,000 work proposed"|"1"|"NAT_GAS"|"S"|"1985"|"5"|"$15,000"|"$15,000 work proposed"|"1"|"S"|"1991"|"20"|"$70,000"|"$85,000 work proposed"|"1"|"DD_MZ"|"1"|"BOILERSTEA"||"S"|"2009"|"20"|"$100,000"|"NO WORK PROPOSED"|"1"|"S"|"2009"|"30"|"$20,000"|"NO WORK PROPOSED"|"1"|"S"|"1991"|"15"|"$505,000"|"$512,000 WORK PROPOSED"|"1"|"S"|"1991"|"15"|"$81,000"|"$54,000 WORK PROPOSED"|"1"|"S"|"1956"|"15"|"$92,000"|"$41,000 WORK PROPOSED"|"1"|"S"|"1991"|"15"|"$189,000"|"$18,000 WORK PROPOSED SOME 1956 UNITS REMAIN"|"1"|"S"|"1991"|"15"|"$50,000"|"$7,000 WORK PROPOSED"|"1"|"S"|"1991"|"15"|"$38,000"|"$2,000 WORK PROPOSED"|"1"|"S"|"1991"|"15"|"$42,000"|"$5,000 WORK PROPOSED"|"1"|"S"|"1991"|"1991"|"$6,000"|"$2,000 WORK PROPOSED A+ HOOD ONLY"|"1"|"S"|"2009"|"20"|"$10,000"|"$5,000 WORK PROPOSED"|"0"||||"0"|"$65,000 WORK PROPOSED"|"1"|"1"||"$5,000 WORK PROPOSED PROVIDE ADA SIGNAGE"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"819,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"FAIR"||"$6,386,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/14/2010 11:22:43 AM| 237|"Caledonia-Mumford CSD"|"24020104"|"Bus Garage"|"5006"|"05/24/2010"|"99 North St"|"Caledonia"|" 14423"|"ANNUAL"|"08/01/2011"|"1997"|"6550"|"1"|"10"|"0"|"DISTRICT"|"OTHER"|"vehicle maintenance/storage"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"2"|"6000"|"0"|"0"|"S"|"1998"|"10"|"0"||"1"|"MUN_UTILIT"|"E"|"1998"|"10"|"0"||"1"|"SITESEPT"|"S"|"1998"|"5"|"0"||"1"|"E"|"1998"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"1998"|"10"|"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"15"|"0"|"Drives are in satisfactory condition, parking lots require some resurfacing. Estimated cost of repairs - $5000."|"1"|"CONCRETE"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"|"We recommend the installation of some exterior lights and emergency lights at exterior doors. Wash bay fixtures can be upgraded to T8 lamps with electronic ballasts for energy efficiency. Estimated cost - $2500."|"1"|"1"|"S"|"1998"|"5"|"0"|"We recommend adding video surveillance, access control points and data drops. Estimated cost - $7500."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1997"|"10"|"0"||"1"|"COMMON"|"S"|"1997"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1997"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"1997"|"20"|"0"||"1"|"METAL"|"S"|"1997"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"10"|"0"|"Broken window seal in wash bay overhead door needs to be repaired. Estimated cost - $250."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1997"|"10"|"0"|"Exterior window in maintenance bay has broken seal that needs to be repaired. Estimated cost - $250."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1998"|"15"|"0"||"1"|"IRON"|"S"|"1998"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"|"Sinks, shower stalls and flush valves need to be brought up to current codes/ADA requirements. Estimated cost - $12,650."|"1"|"CV"|"0"|"OTHER"|"gas RTU, radiant gas fired heaters"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"|"A/V devices should be added to the Men's & Women's toilet rooms. Estimated cost - $750."|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1998"|"1998"|"0"||"1"|"S"|"1997"|"15"|"0"|"Provide emergency battery backup remote head outside egress doors. Estimated cost - $750."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"||||"1"||"FAIR"||"$65,920"|"S"|"1"|"Hunt Engineers, Architects, Land Surveyors, P.C."|"4 Commercial Dr. Suite 300, Rochester, NY 14614"|"585-327-7950"|"cakej@hunt-eas.com"|"John Cake, AIA"|"013885"|"I ACCEPT"|12/14/2010 11:29:50 AM| 239|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG 2 INSTR "|"0002"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1972"|"31,396"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT"||"121"|"7,8,9,10,11,12"|"0"|"1"|"0"|"121"|"0"|"0"|||"11"|"17,773"|"COMPROOM,HOMECAREER,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"$200,000"|"Municipal provision for building isolation required. "|"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"|"Municipal"|"1"|"S"|"1972"|"4"|"0"|"Provisions for building isolation required. "|"1"|"UTIL"|"BELOW"|"S"|"1972"|"5"|"$200,000"|"Underground primary to secondary substation. "|"0"||||"0"||"1"|"S"|"2007"|"10"|"$40,000"||"1"|"S"|"1992"|"3"|"30,000"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1999"|"10"|"20,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"10,000"|"Rework parking lot drainage."|"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Provide slurry seal in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"10"|"0"||"0"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"5"|"$20,000"|"Acoustical lay-in ceiling tiles."|"0"||||"0"||"1"|"S"|"S"|"1972"|"5"|"$20,000"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"10"|"$8,250"|"Relocate transformer, panel and disconnect switch from Shop Area. "|"1"|"S"|"2002"|"10"|"0"|"Light in common projects."|"1"|"1"|"S"|"1972"|"2"|"$45,000"|"New PA System."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1972"|"5"|"40,000"||"1"|"INSTRUCT"|"S"|"1972"|"10"|"$150,000"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Metal siding fading, needs to be painted."|"S"|"1972"|"10"|"0"||"1"|"METAL"|"S"|"1972"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"|"New insulation and PVC membrane roofing."|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"0"||"1"|"IRON,COPPER"|"S"|"1972"|"5"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"2"|"$3,000"|"Current WH is not ASME. Recommend tankless gas water heater. "|"1"|"E"|"2010"|"20"|"$3,400"|"Replace all lavatory trim to meet SED metering faucets (4) and insulate in ADA lavatories (2). "|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"2002"|"5"|"37,500"|"Upgrade ventilation."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"|"Upgraded in 2002."|"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"2002"|"5"|"0"||"1"|"S"|"1985"|"5"|"15,000"||"1"|"E"|"2002"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1972"|"5"|"10,000"|"No lighting except for battery. "|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"$29,400"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/14/2010 12:08:03 PM| 240|"Morris CSD"|"47120104"|"BUS GARAGE"|"5005"|"04/22/2010"|"65 MAIN STREET"|"MORRIS"|" 13808"|"ANNUAL"|"06/21/2011"|"1951"|"6102"|"2"|"0"|"0"|"DISTRICT"|"OTHER"||"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"3"|"10,000"|"non functioning level gauge"|"1"|"MUN_UTILIT"|"S"|"1951"|"3"|"20,000"|"mains are over 50 years old"|"1"|"SITESEPT"|"U"|"1951"|"3"|"60,000"|"unknown septic system type or location"|"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1951"|"10"|"0"||"0"||||"0"||"1"|"S"|"1951"|"5"|"10,000"|"unknown discharge location aftr oil-water seperator"|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"10"|"75,000"|"expansion of parking lot"|"1"|"CONCRETE"|"S"|"1951"|"3"|"8500"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"1"|"0"|"0"|"0"|"U"|"1951"|"3"|"30,000"||"1"|"S"|"1951"|"5"|"0"||"1"|"S"|"1951"|"10"|"0"||"1"|"S"|"1951"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1951"|"3"|"16,000"||"0"||||"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"1"|"S"|"1951"|"5"|"0"|"original panels and wiring"|"1"|"U"|"1951"|"3"|"30,000"|"insufficient lighting levels for working conditions"|"1"|"1"|"S"|"2001"|"5"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1951"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"U"|"2001"|"3"|"200,000"||"CONCRETE,MASONRY"|"1"|"1"||"1"|"0"|"1"|"1"|"1"||"U"|"1951"|"3"|"65,000"||"1"|"MASONRY"|"U"|"1951"|"5"|"15,000"|"repoint masonry and cap"|"0"|||||"0"||"U"|"U"|"0"|"0"|"1951"|"3"|"30,000"|"replace exterior doors and frames"|"0"|"CF"|"1951"|"0"|"25,000"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"U"|"NA"|"1951"|"3"|"40,000"||"METONMET"|"BUILTUP"|"1"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"1"||"U"|"2001"|"3"|"200,000"||"0"|||||"0"||"1"|"COPPER"|"S"|"1951"|"5"|"0"||"1"|"IRON"|"U"|"1951"|"3"|"25,000"||"1"|"ELECTRIC"|"U"|"1999"|"1"|"8,000"||"1"|"U"|"1951"|"3"|"35,000"|"create male and female accessible toilet rooms"|"0"||"1"|"BOILERSTEA"||"U"|"1994"|"3"|"75,000"|"original steam system with no traps or controls"|"1"|"S"|"2001"|"5"|"5,000"|"needs new level gauge"|"0"||||"0"||"0"||||"0"||"1"|"U"|"1951"|"3"|"40,000"|"piping is over 60 years old and condensate lines are failing"|"0"||||"0"||"1"|"U"|"1995"|"0"|"20,000"||"1"|"S"|"2001"|"10"|"0"|"4 zone system"|"0"|"NF"|"1951"|"0"|"10,000"|"no smoke detectors on fire alarm system"|"0"||||"0"||"0"||||"10,000"|"no emergency/exit lighting in the building"|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"POOR"||"NA"|"POOR"|"no classrooms"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"1"|"1"|"1"|"POOR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"POOR"|"0"|"POOR"|"no ventilation system in building"|"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"|||"0"|"0"|"0"|"POOR"||"1,500,000"|"U"|"0"|"william taylor architects"|"6432 Baird ave Syracuse NY 13206"|"315-432-0901"|"bill.taylor@taylor-architects.com"|"William F.Taylor"|"015542"|"I accept"|12/14/2010 12:08:07 PM| 241|"Clyde-Savannah CSD"|"65030104"|"FIELD HOUSE"|"7005"|"08/01/10"|"215 GLASGOW ST"|"CLYDE"|" 14433"|"ANNUAL"|"08/01/11"|"1978"|"3460"|"1"|"0"|"0"|"DISTRICT"|"OTHER,OTHER_ORG"||"0"||"0"|"0"|"0"|"0"|"0"|"00"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1995"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1995"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"1"|"S"|"1995"|"20"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1995"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1995"|"20"|"0"||"0"||||"0"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1995"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1995"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1995"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"20"|"0"||"0"|||||"0"||"1"|"PVC"|"S"|"1995"|"20"|"0"||"1"|"IRON"|"S"|"1995"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"2200000"|"S"|"1"|"GV BOCES"|"151 Hyde Parkway, Palmyra, NY 14522"|"315-597-3469"|"kwasson@wflboces.org"|"Kelly Wasson"|"03097117"|"I ACCEPT"|12/14/2010 12:12:18 PM| 244|"Spencerport CSD"|"26100106"|"Transportation Bldg"|"5014"|"04/19/2010"|"2678 NICHOLS ST "|"SPENCERPORT "|" 14559"|"ANNUAL"|"12/01/2011"|"1997"|"10800"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"transportation facility"|"0"||"0"|"0"|"0"||||||"0"|"0"|||"1"|"2"|"300"|"2"|"15000"|"S"|"1997"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"25"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"20"|"0"|"Three pole-mounted transformers with underground secondary."|"1"|"S"|"1997"|"25"|"0"||"0"||||"0"||"1"|"S"|"1997"|"25"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1997"|"25"|"0"||"1"|"S"|"1997"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1997"|"3"|"322,629"|"Mill and repave driveway from Nichols Street to fueling island. Remove and replace asphalt in nort and south lots. Crack seal all other asphalt areas. "|"1"|"ASPHALT"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"30"|"776"|"Fill hole at north foundation wall at bays 26 and 27."|"1"|"S"|"1997"|"40"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"10"|"3,178"|"Replace damaged lockers."|"1"|"S"|"S"|"1997"|"8"|"2,531"|"One interior door needs to be replaced. "|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"15"|"0"|"All equipment appears original and is in good condition."|"1"|"S"|"1997"|"12"|"0"||"1"|"1"|"S"|"1997"|"10"|"0"|"No central intercom or PA system was observed. Security and phone appeared adequate. "|"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"7"|"0"||"1"|"COMMON"|"S"|"1997"|"7"|"0"||"1"|"COMMON"|"S"|"1997"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"30"|"0"|"One small hole in north wall between work bays 26 and 27."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"6"|"10,955"|"Replace hollow metal doors and repair overhead doors."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1997"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"1997"|"15"|"3,027"|"Clean and paint bracing plates between ridge purlins."|"0"|||||"0"||"1"|"COPPER"|"S"|"1997"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1997"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"VAV"|"1"|"FURNACE"||"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"18"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"18"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"S"|"1997"|"18"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"8"|"0"|"Stobes were evident. Coverage appears adequate. Simplex 4004 controller."|"1"|"S"|"1997"|"8"|"0"|"Detection device coverage appears adequate."|"0"||||"0"||"1"|"U"|"1997"|"10"|"6,379"|"Provide supplemental emergency lighting fixtures."|"1"|"S"|"1997"|"8"|"0"|"Operational stand-by system - emergency power provided by 12 volt batteries. "|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"||"0"|||"1"|"1"|"567"|"Replace stained ceiling tile."|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|||"1"||"GOOD"||"663,986"|"U"|"1"|"LaBella Associates, P.C."|"300 State Street, Suite 201, Rochester, NY, 14614"|"585-454-6110"|"mshort@labellapc.com"|"Michael E. Short"|"032717"|"I ACCEPT"|12/14/2010 2:52:29 PM| 245|"West Genesee CSD"|"42010106"|"Onondaga Road Elementary "|"0004"|"7/27/10"|"703 ONONDAGA RD "|"SYRACUSE "|" 13219-2999"|"ANNUAL"|"9/1/2011"|"1956"|"46,772"|"1"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"344"|"K,1,2,3,4,5"|"0"|"0"|"0"|"344"|"0"|"0"|||"26"|"23,774"|"ADMIN,ART,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"35"|"$50,000"|"$24,000 work proposed"|"1"|"MUN_UTILIT"|"S"|"1956"|"35"|"$67,000"|"NO WORK PROPOSED"|"1"|"S"|"1956"|"35"|"$27,000"|"NO WORK PROPOSED"|"1"|"UTIL"|"BELOW"|"S"|"1956"|"25"|"$52,000"|"NO WORK PROPOSED"|"1"|"S"|"2005"|"20"|"$46,000"|"$32,000 WORK PROPOSED"|"1"|"S"|"1956"|"20"|"$10,000"|"NO WORK PROPOSED"|"1"|"U"|"1956"|"5"|"$25,000"|"$25,000 WORK PROPOSED"|"1"|"S"|"1956"|"10"|"$5,000"|"NO WORK PROPOSED"|"1"|"MUNI"||"1"|"S"|"1956"|"15"|"$10,000"|"NO WORK PROPOSED"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"$102,000"|"NO WORK PROPOSED"|"1"|"CONCRETE"|"S"|"1956"|"10"|"$70,000"|"$11,000 WORK PROPOSED"|"1"|"S"|"2009"|"20"|"$170,000"|"NO WORK PROPOSED"|"1"|"S"|"1956"|"5"|"$301,000"|"N"|"$20,000 WORK PROPOSED"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"30"|"$318,000"|"$369,000 WORK PROPOSED"|"1"|"S"|"1956"|"20"|"$81,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"20"|"$106,000"|"$489,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$127,000"|"$175,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$97,000"|"$10,000 WORK PROPOSED"|"1"|"S"|"S"|"2005"|"15"|"$81,000"|"$98,000 WORK PROPOSED"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1993"|"35"|"$88,000"|"$112,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$44,000"|"$87,000 WORK PROPOSED"|"1"|"1"|"S"|"1993"|"15"|"$45,000"|"$45,000 WORK PROPOSED"|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"10"|"$11,000"|"$152,000 WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1993"|"20"|"$88,000"|"$112,000 WORK PROPOSED"|"1"|"COMMON"|"S"|"1993"|"20"|"$34,000"|"$37,000 WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1993"|"20"|"$3,000"|"NO WORK PROPOSED"|"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"25"|"$269,000"|"$368,000 WORK PROPOSED"|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1956"|"15"|"$181,000"|"$425,000 WORK PROPOSED"|"1"|"MASONRY"|"S"|"1956"|"10"|"$24,000"|"NO WORK PROPOSED"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1986"|"10"|"$106,000"|"$69,000 WORK PROPOSED"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1993"|"15"|"$285,000"|"$184,000 WORK PROPOSED"|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"15"|"$396,000"|"$184,000 WORK PROPOSED"|"0"|||||"0"||"1"|"COPPER"|"S"|"1956"|"25"|"$39,000"|"$20,000 WORK PROPOSED"|"1"|"IRON"|"S"|"1956"|"25"|"$45,000"|"$20,000 WORK PROPOSED"|"1"|"NAT_GAS"|"S"|"1991"|"5"|"$17,000"|"$15,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$103,000"|"$88,000 WORK PROPOSED"|"1"|"DD_MZ"|"1"|"BOILERSTEA"||"S"|"2009"|"20"|"$100,000"|"NO WORK PROPOSED"|"1"|"S"|"2009"|"30"|"$20,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$505,000"|"$560,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$13,000"|"$78,000 WORK PROPOSED"|"1"|"S"|"1956"|"15"|"$92,000"|"$34,000 WORK PROPOSED"|"1"|"S"|"1993"|"25"|"$189,000"|"$15,000 WORK PROPOSED. SOME 1956 UNITS REMAIN"|"1"|"S"|"1993"|"15"|"$50,000"|"$5,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$38,000"|"$2,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$42,000"|"$5,000 WORK PROPOSED"|"1"|"S"|"1993"|"1993"|"$6,000"|"$2,000 WORK PROPOSED. A+ HOOD ONLY"|"1"|"S"|"1993"|"15"|"$22,000"|"$5,000 WORK PROPOSED"|"0"||||"0"|"$65,000 WORK PROPOSED"|"1"|"1"||"$5,000 WORK PROPOSED. PROVIDE ADA SIGNAGE"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"819,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"FAIR"|"NEED CAFETERIA"|"$5,333,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/14/2010 2:58:25 PM| 246|"Salamanca City SD"|"04320005"|"Prospect Elementary"|"0008"|"08/19/2010"|"300 Prospect Avenue"|"Salamanca"|" 14779"|"ANNUAL"|"07/01/2011"|"1963"|"76,100"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"384"|"Pre-K,K,1,2"|"0"|"1"|"1"|"384"|"0"|"0"|||"24"|"20,020"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"1"|"15000"|"Install an additional fire hydrant"|"1"|"MUN_UTILIT"|"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"1"|"S"|"1991"|"1"|"10000"|"Replace deteriorated catch basins."|"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"5"|"15000"|"Replace deteriorated asphalt pavement at the receiving / dumpster area."|"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"5"|"10000"|"Replace concrete sidewalks."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"15"|"0"||"1"|"S"|"1963"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"0"|"S"|"2008"|"1"|"25000"|"Provide additional receptacles and replace devices in the original building."|"1"|"S"|"2008"|"1"|"45000"|"Replace remaining T12 fluorescent lights and stage lighting."|"1"|"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2008"|"15"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"25"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2008"|"20"|"0"||"1"|"MASONRY"|"S"|"1963"|"5"|"50000"|"Repoint all masonry, new stainless steel rain cap, stainless steel cover over unused flue, repaint access doors, remove all debris and dispose off site."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"10"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2008"|"20"|"0"||"1"|"PLASTIC"|"S"|"2006"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"2006"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1991"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2006"|"20"|"0"||"1"|"S"|"1991"|"5"|"30000"|"Replace old original plumbing fixtures and install additional water coolers."|"0"||"1"|"BOILERWATE"||"S"|"1997"|"3"|"80000"|"Replace one (1) cast iron boiler."|"1"|"S"|"1997"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"2008"|"5"|"100000"|"Replace miscellaneous exhaust fans, relief hoods, ptacs, etc."|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"2008"|"1"|"5000"|"Replace older visual signals."|"1"|"S"|"2008"|"1"|"5000"|"Replace older smoke detectors."|"1"|"S"|"1995"|"1995"|"0"||"1"|"S"|"2008"|"1"|"2500"|"Install additional exit signs."|"1"|"S"|"2008"|"25"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"||"1"|"1"||"GOOD"||"$392,500"|"S"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/14/2010 3:03:45 PM| 251|"Salamanca City SD"|"04320005"|"Middle / High School"|"0002"|"07/22/2010"|"50 Iroquois Drive"|"Salamanca"|" 14779"|"ANNUAL"|"07/01/2011"|"1956"|"216,120"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"712"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"712"|"0"|"0"|||"60"|"52,400"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1991"|"10"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2006"|"1"|"25000"|"Replace Aerial lighting service wiring at Tennis Courts with underground service wiring."|"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"S"|"2006"|"5"|"35000"|"Replace existing catch basins and existing storm piping at the main parking lot."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"1"|"530000"|"Reconstruct the main bus loop and main asphalt parking lot."|"1"|"CONCRETE,ASPHALT"|"S"|"1998"|"1"|"120000"|"Replace concrete curbs and sidewalks with parking lot construction."|"0"||||"0"||"1"|"E"|"2007"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"S"|"2008"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"1986"|"5"|"40000"|"Replace existing freight lift to the basement / mechanical room."|"1"|"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"1"|"S"|"2006"|"5"|"Replace all Middle School clocks."||"1"|"S"|"2006"|"20"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"2008"|"20"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"25"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"none"|"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"|"none"|"0"|"0"|"0"|"0"|"0"|"none"|"S"|"2008"|"25"|"0"||"1"|"MASONRY"|"S"|"1986"|"5"|"60000"|"The existing chimney and old incinerator is not in use. Demo and remove existing chimney construction and infill roof."|"1"|"MASONRY"|"E"|"2008"|"20"|"0"||"S"|"S"|"0"|"1"|"2008"|"2"|"7500"|"Replace existing frame & door with new aluminum frame, door & hardware at Home & Careers room in the Middle School."|"1"|"E"|"2006"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2008"|"20"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"none"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"none"|"S"|"2008"|"20"|"0"||"1"|"PLASTIC"|"S"|"2006"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2006"|"20"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"1991"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"5"|"100000"|"Replace and upgrade existing plumbing fixtures and install additional water coolers."|"0"||"1"|"GEOTHERMAL"||"E"|"2008"|"25"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2006"|"1"|"15000"|"Replace visual signals at the Middle School."|"1"|"S"|"2006"|"6"|"0"||"1"|"S"|"2006"|"2006"|"0"||"1"|"S"|"2006"|"1"|"40000"||"1"|"E"|"2006"|"25"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"$987,500"|"S"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/14/2010 5:36:02 PM| 252|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG 3 "|"0003"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1972"|"16,930"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"105"|"7,8,9,10,11,12"|"0"|"1"|"0"|"105"|"0"|"0"|||"6"|"8209"|"ADMIN,REMEDIAL,TECHSHOP,OTHER"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"10"|"0"|"Backflow protection installed."|"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"|"Provisions for building isolation required."|"1"|"UTIL"|"BELOW"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"40,000"||"1"|"S"|"1992"|"3"|"30,000"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1999"|"10"|"20,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"80,000"|"Slurry seal provided in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Slurry seal provided in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"10"|"0"||"1"|"S"|"1973"|"10"|"0"||"1"|"S"|"1973"|"10"|"0"||"1"|"S"|"1973"|"5"|"10,000"|"Lay-in acoustical."|"0"||||"0"||"1"|"S"|"S"|"1973"|"5"|"8,000"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"5"|"30,000/7,400"|"Replace transformers/replace electrical distribution and lighting in Greenhouse."|"1"|"S"|"1973"|"10"|"0"|"T-12 Fluorescent"|"1"|"1"|"S"|"1973"|"3"|"2,000/30,000"|"Replace corrective clocks/new PA system. "|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2010"|"5"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"5"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"5"|"4,000"|"Grind terrazo floor. "|"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"10"|"0"|"Masonry and brick."|"1"|"METAL"|"S"|"2010"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2004"|"15"|"0"|"New insulation and PVC membrane roofing."|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"2"|"35,000/3,400"|"Replace domestic piping/lavatory trim."|"1"|"IRON,COPPER"|"S"|"1994"|"5"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"2"|"3,000"|"Current WH is not ASME. Recommend tankless gas water heater. "|"1"|"S"|"1994"|"5"|"3,400"|"Replace lavatory trim."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"2000"|"5"|"26,500"|"C-Ray Vac installed."|"1"|"S"|"1973"|"5"|"0"|"Natural gas piping."|"1"|"S"|"1988"|"3"|"20,000/17,500/6,000"|"Replace heat pumps/replace chiller/ add Sanyo split in Office Area."|"1"|"S"|"1973"|"5"|"0"||"1"|"S"|"1994"|"10"|"0"|"Added heat pumps."|"1"|"S"|"1973"|"5"|"18,500"||"1"|"S"|"1973"|"5"|"10,000"|"Connect to Johnson Control System."|"1"|"E"|"2001"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1994"|"3"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"77,900"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/15/2010 8:57:45 AM| 254|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"PAULINE C BUSH CNT "|"0001"|"05/06/2010"|"459 PHILO RD BLDG #1 "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1972"|"69,333"|"2"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"198"|"3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"198"|"0"|"0"|"CAFE,GYM,ADM_SPC,LIB,STAIR,STORAGE"||"26"|"29,115"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,HOMECAREER,KITCHEN,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"600,000"|"Municipal-Provision for building isolation required."|"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"15,000"|"Municipal"|"1"|"S"|"1972"|"5"|"40,000"|"Provisions for building isolation required."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"5"|"100,000/30,000"|"Underground primary to secondary substation. Replace transformers. "|"0"||||"0"||"1"|"S"|"2007"|"10"|"40,000"||"1"|"S"|"1992"|"3"|"30,000"||"1"|"S"|"1999"|"5"|"20,000"||"1"|"SURFACEH2O"||"1"|"S"|"1999"|"10"|"20,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"100,000"|"Provide slurry seal in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"PRovide slurry seal in 2007."|"1"|"S"|"1991"|"3"|"60,000"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"|"Gymnasium addition in 1994."|"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1994"|"5"|"50,000"|"Acoustical lay-in ceiling tiles."|"1"|"S"|"1994"|"5"|"0"||"1"|"S"|"S"|"1994"|"3"|"20,000"|"Wood and hollow metal doors. "Best" exterior keying, "Sargent" interior. "|"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"2003"|"10"|"60,000"||"1"|"1"|"S"|"1972"|"5"|"40,000"|"Upgrades to primary switch needed. Primary switchgear, 500kVA, 12.47kV, 208/120."|"1"|"S"|"1972"|"5"|"100,000"|"Upgrade existing T-12 fluorescent w/non electronic ballast to T-8 fluorescent. "|"1"|"1"|"S"|"1972"|"5"|"70,000"|"New PA system. "|"0"||||"0"||"1"|"COMMON"|"S"|"2006"|"5"|"100,000"|"Carpet located in Business Suites/Offices. "|"1"|"INSTRUCT"|"S"|"2007"|"5"|"120,000"|"VAT floor tile remains in some classrooms."|"1"|"COMMON"|"S"|"2001"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2007"|"10"|"0"|"Kitchen/Home Economics Renovation - 2007."|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Metal siding fading-need to be painted."|"S"|"1994"|"10"|"0"|"Masonry with brick back-up."|"1"|"MASONRY"|"S"|"1972"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"10"|"0"||"1"|"S"|"1972"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"15"|"478,000"|"New roof provided in 2005."|"1"|"PLASTIC"|"S"|"2003"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1972"|"5"|"50,000/5,000"|"Replace domestic piping from Mechanical Room to pipe chases in 1972 Building./Replace water softener for hot water and kitchen use. "|"1"|"IRON,COPPER"|"S"|"1994"|"5"|"0"|"Replace domestic piping from Mechanical Room to pipe chases in 1972 Building."|"1"|"NAT_GAS"|"S"|"1994"|"5"|"18,000"|"Replace Burkey Heater with high efficiency condensing gas water heater, storage tank in good shape. "|"1"|"S"|"1994"|"5"|"9,000/4,500"|"Replace all lavatory trim with metering faucet to meet SED (Typical of 10) and ADA insulation on ADA Typical (6)/Replace drinking fountain in original building (Typical 3)."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1994"|"5"|"510,000"|"Natural gas, circ., hot water, Weil-McLain with Webster burners. "|"1"|"S"|"1994"|"5"|"15,000"|"Johnson Control"|"1"|"S"|"1994"|"5"|"10,000"|"Heat pump replacement and maintenance."|"1"|"S"|"2001"|"10"|"0"|"Make-up air units replaced in 2001."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"5"|"150,000"|"Upgrade Johnson Controls."|"1"|"S"|"2001"|"10"|"0"|"Campus Wide upgrade in 2001."|"1"|"S"|"2001"|"10"|"0"|"Campus Wide upgrade in 2001."|"1"|"S"|"2007"|"2007"|"20,000"||"1"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"FULL"|"0"|"1"|"0"|"FAIR"||"1,168,500"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/15/2010 9:55:43 AM| 255|"Salamanca City SD"|"04320005"|"Seneca Elementary"|"0009"|"09/09/2010"|"25 Center Street"|"Salamanca"|" 14779"|"ANNUAL"|"07/01/2011"|"1964"|"60,925"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"305"|"3,4,5"|"0"|"1"|"1"|"305"|"0"|"0"|||"22"|"18,200"|"ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"1"|"100000"|"Add Fire Hydrant and Backflow preventer."|"1"|"MUN_UTILIT"|"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"1"|"40000"|"Add Site Lighting at the rear parking lot."|"1"|"S"|"1964"|"10"|"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"5"|"50000"|"Reconstruct the existing asphalt rear parking lot (south of the building)."|"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"15"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"S"|"1991"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"5"|"40000"|"Replace ceilings in the classrooms of the original classroom wing."|"0"||||"0"||"1"|"S"|"S"|"2008"|"15"|"0"||"1"|"S"|"1964"|"10"|"0"||"1"|"S"|"1964"|"10"|"0"||"1"|"0"|"S"|"2008"|"1"|"25000"|"Provide additional receptacles and replace devices in the original building."|"1"|"S"|"2008"|"1"|"50000"|"Replace remaining T12 flourescent lights, gym lighting and stage lighting."|"1"|"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"1991"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2006"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1991"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2008"|"20"|"0"||"1"|"MASONRY"|"S"|"1964"|"5"|"50000"|"Repoint all masonry, new stainless steel rain cap, stainless steel cover over unused flue, repaint access doors, remove all debris and dispose off site."|"0"|||||"0"||"E"|"E"|"0"|"1"|"2010"|"20"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"2008"|"5"|"10000"|"Replace remaining original window, slate, louver, etc. with new aluminum insulated windows."|"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2008"|"20"|"0"||"1"|"PLASTIC"|"S"|"1991"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1991"|"5"|"50000"|"Replace original piping."|"1"|"IRON,COPPER"|"S"|"1991"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2008"|"20"|"0"||"1"|"S"|"1991"|"5"|"30000"|"Upgrade & replace existing plumbing fixtures and install additional hose bibbs."|"0"||"1"|"BOILERWATE"||"S"|"1997"|"3"|"80000"|"Replace one (1) cast iron boiler."|"1"|"S"|"1997"|"15"|"0"||"1"|"E"|"2008"|"5"|"5000"|"Demolition of abandoned A/C equipment."|"1"|"S"|"2008"|"5"|"60000"|"Replace miscellaneous exhaust fans and sheet metal accessories."|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"2008"|"1"|"5000"|"Replace older visual signals."|"1"|"S"|"2008"|"1"|"10000"|"Replace older smoke detectors."|"1"|"S"|"1995"|"1995"|"0"||"1"|"S"|"2008"|"1"|"2000"|"Install additional exit signs."|"1"|"S"|"2008"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"||"1"|"1"||"GOOD"||"$597,000"|"S"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/15/2010 10:06:55 AM| 258|"Falconer CSD"|"06110104"|"Paul B. D. Temple Elementary School"|"0007"|"07/12/2010"|"3470 Cemetary Street"|"Kennedy"|" 14747"|"ANNUAL"|"08/01/2011"|"1956"|"54,239"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"|"Athletics and Extracurricular"|"268"|"Pre-K,K,1,2"|"0"|"1"|"0"|"268"|"0"|"0"|||"20"|"8,000"|"ADMIN,ART,AUDITORIUM,CAFE,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"WELL"|"S"|"2000"|"15"|"0"||"1"|"SITESEPT"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"3"|"55,000"|"All asphalt surfaces need to be milled and resurfaced"|"1"|"CONCRETE"|"S"|"2000"|"5"|"8,000"|"Some walks are cracked and heaved. Expansion joints need cleaned and caulked. Small trip hazzard at front entrance."|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"5"|"10,000"|"N"|"Fabric on baseball backstop is rusting and could be replaced."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"3"|"30,000"|"Some classrooms and the gym have T-12 lamps and ballasts that should be changed to T-8 lamps and ballasts for energy efficiency."|"1"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"2"|"5,000"|"Teacher lounge should be replaced "|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"15"|"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"1"|"1"|"0"||"S"|"2005"|"5"|"25,000"|"Some minor masonry restoration needed. Stone sills and other stone joints need to be recut and caulked. Stone could use some cleaning."|"1"|"MASONRY"|"S"|"2005"|"10"|"5,000"|"Some minor repointing needed."|"1"|"MASONRY"|"S"|"2005"|"15"|"0"||"S"|"S"|"0"|"1"|"2000"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"15"|"0"||"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"10"|"0"||"1"|"PLASTIC"|"S"|"2005"|"10"|"0"||"1"|"COPPER"|"S"|"2000"|"12"|"0"||"1"|"IRON"|"S"|"2000"|"12"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"12"|"0"||"1"|"S"|"2000"|"5"|"10,000"|"Water closet and urnial flush valves and seats need to be upgraded."|"0"||"1"|"BOILERWATE"||"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"3"|"34,000"|"A number of exhaust fans and intake hoods and fans on older portion of building are worn and noisy and should be replaced. "|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"12"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"1"|"20,000"|"Existing stage is not accessible"|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"1"|"1"|"0"|"1"|"HVAC,SUMPPUMP,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"182,000"|"E"|"1"|"Harrington Sandberg Architecture and Engineering, P.C."|"500 E Sixth St., Jamestown, NY 14701"|"716-483-3153"|"mb@harringtonsandberg.com"|"Ronald I. Kessler, R.A."|"023043"|"I ACCEPT"|12/15/2010 10:30:45 AM| 259|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"INSTRUCTIONAL COMPLEX (BLDG 4) "|"0004"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1967"|"13,420"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER"|"Head Start (Daycare)"|"36"|"Pre-K,K,1,2,3,4,5,6,7"|"0"|"1"|"1"|"36"|"0"|"0"|||"6"|"3921"|"ADMIN,COMPROOM,PREK"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"|"Backflow protection installed."|"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"|"Provisions for building isolation required."|"1"|"UTIL"|"BELOW"|"S"|"1972"|"5"|"30,000"|"Replace transformers."|"0"||||"0"||"1"|"S"|"2007"|"10"|"40,000"||"1"|"S"|"1992"|"3"|"20,000"||"1"|"S"|"1999"|"5"|"20,000"||"1"|"SURFACEH2O"||"1"|"S"|"1999"|"10"|"20,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"2"|"0"|"Slurry seal in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Slurry seal in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"10"|"60,000"||"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"5"|"40,500"||"0"||||"0"||"1"|"S"|"S"|"1972"|"5"|"12,000"|"Wood & hollow metal doors."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"1972"|"5"|"0"|"Fluorescent T-12 with non-electric ballast."|"1"|"1"|"S"|"1972"|"3"|"20,000"|"Replace PA system."|"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"5"|"40,000"||"1"|"INSTRUCT"|"S"|"1972"|"5"|"80,000"|"VAT flooring needs to be removed under abatement conditions."|"1"|"COMMON"|"S"|"1972"|"2"|"60,000"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"10"|"80,0000"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"10"|"0"||"1"|"METAL"|"S"|"1972"|"5"|"0"||"0"|||||"0"||"S"|"E"|"0"|"1"|"2004"|"10"|"20,000"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2004"|"10"|"45,000"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2004"|"15"|"200,000"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"5"|"0"||"1"|"NAT_GAS"|"S"|"2010"|"15"|"3,000"|"Tank not ASME. Replace with tankless gas water heater."|"1"|"S"|"1972"|"3"|"50,000"|"Replace fixtures."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1994"|"5"|"0"|"HP Smith hot water, natural gas."|"1"|"S"|"1972"|"5"|"0"|"Natural gas piping."|"1"|"S"|"1992"|"4"|"25,000"|"Cooling upgrades needed for efficiency."|"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"1994"|"1"|"10,000"|"Power back-up needed."|"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"4"|"0"|"Johnson Control"|"1"|"E"|"2001"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1972"|"2"|"10,000"|"No lighting except for battery. "|"1"|"E"|"2010"|"10"|"100,000"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"1,585,400"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/15/2010 11:15:01 AM| 260|"Union Springs CSD"|"05190104"|"Cayuga Elementary"|"0004"|"9/3/10"|"255 Wheat Street"|"Cayuga"|" 13160"|"ANNUAL"|"10/1/10"|"1952"|"43978"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"237"|"K,1,2"|"0"|"0"|"1"|"237"|"0"|"0"|||"20"|"16536"|"ADMIN,CAFE,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1952"|"10"|"0"|"Ongoing issue w/ water quality (seasonal)."|"1"|"MUN_UTILIT"|"S"|"1952"|"10"|"0"||"1"|"S"|"1966"|"10"|"0"|"NYSEG"|"1"|"UTIL"|"BELOW"|"S"|"2009"|"10"|"0"|"Upgraded site lighting."|"1"|"S"|"1998"|"20"|"0"|"Property is seasonally wet due to high ground water table & topography"|"1"|"U"|"1998"|"5"|"88000"|"Seasonally wet; recommend installing under drain system & storm inlets"|"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1998"|"10"|"0"|"Discharge to roadside ditch & catch basin"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"5"|"13000"|"Recommend re-striping & seal cracks"|"1"|"CONCRETE,ASPHALT"|"U"|"1998"|"5"|"26000"|"Recommend replacing broken sidewalk @ bus loop; suggest replacing asphalt w/ concrete"|"1"|"U"|"1998"|"5"|"21000"|"Recommend replacing wood fiber mulch & seal basketball court"|"1"|"U"|"1952"|"5"|"350000"|"N"|"Seasonally wet; Recommend adding under-drainage system/create full size field"|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"1"|"S"|"1952"|"10"|"5000"|"Recommend parging/painting in miscellaneous areas."|"1"|"S"|"1952"|"10"|"0"||"1"|"S"|"1952"|"10"|"0"||"1"|"U"|"2009"|"5"|"7000"|"Recommend replacing @ gym corridor/lobby and Offices of Special Services"|"0"||||"0"||"1"|"S"|"S"|"2009"|"20"|"0"|"Door hardware & master keying system w/ EXCEL funds."|"1"|"S"|"1952"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"1"|"S"|"2009"|"10"|"61000"|"Recommend replacing clocks w/ wireless (Owner request)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1995"|"5"|"16000"|"Recommend replacing @ library and Office of Special Programs"|"1"|"INSTRUCT,COMMON"|"S"|"1995"|"10"|"0"||"1"|"COMMON"|"S"|"2005"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1952"|"20"|"0"|"Ongoing maintenance (sealing)"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1952"|"25"|"0"||"MASONRY,STEEL,WOOD"|"0"|"0"|"Uninsulated - District requests improved insulation/energy savings"|"1"|"0"|"0"|"0"|"0"|"peeling paint"|"S"|"1952"|"10"|"0"|"Recommend scraping/parging/painting various painted walls; install EIFS system"|"1"|"CONCRETE"|"S"|"1966"|"5"|"2000"|"Recommend scraping/parging/painting"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"5"|"17000"|"Recommend replacing misc. doors & door hardware."|"1"|"S"|"1998"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1980"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"10"|"0"||"1"|"PLASTIC"|"S"|"2003"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2005"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2005"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"15"|"0"||"1"|"U"|"1952"|"5"|"158000"|"Replace original fixtures in (6) classrooms"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2000"|"10"|"70000"|"Add A/C to library and (2) data closets "|"1"|"U"|"1966"|"5"|"61000"|"Replace exhaust fans and add ventilation in (4) off/conf rms in SW wing"|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1952"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"|"Johnson Controls "|"1"|"U"|"1998"|"5"|"158000"|"Replace Simplex 4002 8-zone FACP w/ addressable system; add classroom strobes"|"1"|"U"|"1998"|"5"|"53000"|"Add point addressable detectors w/ new FACP"|"0"||||"0"||"1"|"U"|"2005"|"5"|"10000"|"Recommend adding ansul system over gas range in kitchen"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"|"District will be discussing consolidation of elementary facilities. "|"1416000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/15/2010 11:25:17 AM| 261|"West Genesee CSD"|"42010106"|"Camillus Middle School "|"0012"|"7/27/10"|"5525 IKE DIXON ROAD "|"CAMILLUS "|" 13031-9621"|"ANNUAL"|"9/1/2011"|"1972"|"156,560"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"534"|"6,7,8"|"0"|"0"|"0"|"534"|"0"|"0"|||"54"|"66,059"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"25"|"$200,000"|"NO WORK PROPOSED"|"1"|"MUN_UTILIT"|"E"|"2005"|"40"|"$100,000"|"NO WORK PROPOSED"|"1"|"S"|"1972"|"15"|"$62,000"|"NO WORK PROPOSED"|"1"|"UTIL"|"BELOW"|"S"|"1972"|"25"|"$97,000"|"NO WORK PROPOSED"|"1"|"S"|"2005"|"20"|"$97,000"|"$82,000 WORK PROPOSED"|"1"|"S"|"2005"|"20"|"$50,000"|"$25,000 WORK PROPOSED"|"1"|"U"|"1972"|"5"|"$75,000"|"$75,000 WORK PROPOSED"|"1"|"S"|"2005"|"20"|"$10,000"|"NO WORK PROPOSED"|"1"|"SURFACEH2O"||"1"|"S"|"1972"|"10"|"$10,000"|"NO WORK PROPOSED"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2005"|"20"|"$500,000"|"$38,000 WORK PROPOSED"|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"15"|"$100,000"|"$30,000 WORK PROPOSED"|"0"||||"0"||"1"|"E"|"2005"|"20"|"$350,000"|"N"|"$442,000 WORK PROPOSED"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"25"|"$194,000"|"NO WORK PROPOSED"|"1"|"S"|"1972"|"25"|"$124,000"|"NO WORK PROPOSED"|"1"|"S"|"1999"|"20"|"$127,000"|"$25,000 WORK PROPOSED"|"1"|"S"|"1999"|"15"|"$199,000"|"$10,000 WORK PROPOSED"|"1"|"S"|"1972"|"5"|"$135,000"|"$25,000 WORK PROPOSED"|"1"|"S"|"S"|"1999"|"10"|"$140,000"|"$15,000 WORK PROPOSED"|"1"|"S"|"1999"|"25"|"$194,000"|"$8,000 WORK PROPOSED"|"1"|"S"|"1999"|"10"|"$178,000"|"NO WORK PROPOSED"|"1"|"1"|"S"|"1999"|"20"|"$172,000"|"$6,000 WORK PROPOSED"|"1"|"S"|"1999"|"15"|"$196,000"|"$37,000 WORK PROPOSED"|"1"|"1"|"S"|"1999"|"15"|"$106,000"|"$84,000 WORK PROPOSED"|"0"||||"0"||"1"|"INSTRUCT"|"U"|"1999"|"5"|"$12,000"|"$12,000 WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1999"|"15"|"$162,000"|"$5,000 WORK PROPOSED"|"1"|"COMMON"|"S"|"1999"|"15"|"$46,000"|"$18,000 WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1999"|"10"|"$12,000"|"NO WORK PROPOSED"|"CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"25"|"$8,618,000"|"NO WORK PROPOSED"|"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"1"|"REBAR RUST AT PRECAST CONC. SILLS."|"S"|"1972"|"25"|"$2,693,000"|"$70,000 WORK PROPOSED"|"1"|"MASONRY"|"S"|"1972"|"25"|"$19,000"|"NO WORK PROPOSED"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"15"|"$135,000"|"$63,000 WORK PROPOSED"|"1"|"S"|"1999"|"20"|"$17,000"|"$5,000 WORK PROPOSED"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"20"|"$350,000"|"$18,000 WORK PROPOSED"|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"25"|"$102,000"|"$8,000 WORK PROPOSED"|"1"|"PLASTIC"|"S"|"2005"|"25"|"$102,000"|"$8,000 WORK PROPOSED"|"1"|"COPPER"|"S"|"1999"|"35"|"$129,000"|"$3,000 WORK PROPOSED - SOME 1972 VINTAGE REMAINS IN USE."|"1"|"IRON"|"S"|"1999"|"35"|"$151,000"|"$2,000 WORK PROPOSED - SOME 1972 VINTAGE REMAINS IN USE."|"1"|"NAT_GAS"|"S"|"2010"|"20"|"$19,000"|"NO WORK PROPOSED"|"1"|"S"|"1999"|"15"|"$74,000"|"$26,000 WORK PROPOSED"|"1"|"DD_MZ"|"1"|"BOILERWATE"||"S"|"1999"|"35"|"$199,000"|"NO WORK PROPOSED"|"1"|"S"|"1999"|"35"|"$24,000"|"NO WORK PROPOSED"|"1"|"S"|"1999"|"35"|"$189,000"|"NO WORK PROPOSED"|"1"|"S"|"1997"|"35"|"$181,000"|"$90,000 WORK PROPOSED"|"1"|"S"|"1999"|"20"|"$124,000"|"$3,000 WORK PROPOSED"|"1"|"S"|"1999"|"20"|"$192,000"|"$3,000 WORK PROPOSED - SOME ORIGINAL REMAINS IN USE."|"1"|"S"|"1999"|"15"|"$78,000"|"$5,000 WORK PROPOSED"|"1"|"S"|"1999"|"15"|"$127,000"|"$20,000 WORK PROPOSED"|"1"|"S"|"1999"|"15"|"$139,000"|"$5,000 WORK PROPOSED"|"1"|"S"|"1999"|"1999"|"$17,000"|"NO WORK PROPOSED"|"1"|"S"|"1999"|"15"|"$73,000"|"NO WORK PROPOSED"|"0"||||"0"|"$137,000 WORK PROPOSED"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"2,740,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"GOOD"||"$1,594,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/15/2010 11:50:35 AM| 262|"Caledonia-Mumford CSD"|"24020104"|"Elementary Building"|"0003"|"05/24/2010"|"99 North St"|"Caledonia"|" 14423"|"ANNUAL"|"08/01/2011"|"1938"|"87370"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"454"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"0"|"454"|"0"|"0"|||"28"|"21700"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1935"|"0"|"$25,000"||"1"|"SITESEPT"|"S"|"1998"|"10"|"0"||"1"|"E"|"1998"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"1998"|"10"|"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"20"|"0"|"Drives are in satisfactory conditiion, parking lots require some curbing and asphalt patching. Estimated cost - $30,000."|"1"|"CONCRETE"|"S"|"1998"|"10"|"0"|"There are that need to be repaired. Estimated cost - $10,000."|"1"|"S"|"1991"|"5"|"0"|"1950 Playground is non-compliant with today's standards, codes and regulations. Estimated cost to update - $180,000."|"1"|"E"|"2006"|"15"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1954"|"0"|"0"|"Wood and metal lockers in the 2nd floor 1954 wing classrooms should be replace. Estimated cost - $50,000."|"1"|"S"|"S"|"1998"|"10"|"0"|"Aside from the 1998 addition, many corridor doors are in poor condition and not fire rated in accordance with current code requirements."|"1"|"S"|"1998"|"15"|"0"|"Terrazzo stairs are cracked and worn, some steel reinforcing is exposed. Estimated cost - $6,000 - $12,000."|"1"|"S"|"1998"|"5"|"0"||"1"|"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"2008"|"5"|"0"|"Replace T12 fixtures with T8 fixtures. Replace metal halide fixtures in the gym, provide addtioinal occupancy sensors throughout the building - all items to increase energy efficiency. Estimated cost -$30,000."|"1"|"1"|"S"|"2008"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"E"|"2008"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"10"|"0"|"Asbestos tile and mastic are located throughout the 1938 wing classrooms. Estimated abatement cost - $150,000."|"1"|"COMMON"|"S"|"1998"|"20"|"0"|"Terrazzo floors are cracked and worn, some steel reinforcing is exposed. Quarry tile in cafeteria is in satisfactory condition. Estimated cost terrazzo repairs - $190,000."|"1"|"INSTRUCT"|"S"|"1998"|"20"|"0"|"Wood parquet flooring in the 1938 wing 1st floor classrooms is in poor condition. Estimated cost for repair/replace - $90,000. Auditorium floor is in excellent condition."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1998"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"10"|"0"|"Corridor 201, between buildings, a concrete beam is cracked and should be periodly inspected. If movement continues - remediation will be necessary. Masonry re-pointing needed on older facade areas. Estimated cost - $9,000."|"1"|"MASONRY"|"S"|"2008"|"15"|"0"||"1"|"MASONRY"|"S"|"1998"|"10"|"0"||"S"|"S"|"1"|"1"|"1998"|"10"|"0"|"Roof door at upper gymnasium needs to be replaced. Estimated cost - $700."|"1"|"S"|"1998"|"10"|"0"||"0"|||||"0"||"0"|"ALUMINUM,STEEL,WOODCLAD"|"S"|"Y"|"1998"|"5"|"0"|"There are windows that need to be resealed and several that need to be replaced. Estimated cost - $46,425."|"CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"0"||"S"|"1998"|"10"|"0"|"Excessive ponding on roof needs to be addressed. Bell tower needs a scupper and 1954 gym scupper needs a gravel stop. Tenting at parapet may be covered under warranty. Estimated cost $45,450."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2008"|"10"|"0"||"1"|"IRON"|"S"|"1998"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"|"Sinks & toilets for ADA compliance - $50,000. Sanitary piping replacement and abatement - $260,000."|"0"||"1"|"BOILERSTEA"||"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"E"|"2006"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"1"|"1"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM"|"FULL"||"1"||"GOOD"||"$4,295,550"|"S"|"1"|"Hunt Engineers, Architects, Land Surveyors, P.C."|"4 Commercial Dr. Suite 300, Rochester, NY 14614"|"585-327-7950"|"cakej@hunt-eas.com"|"John Cake, AIA"|"013885"|"I ACCEPT"|12/15/2010 12:30:23 PM| 263|"Spencerport CSD"|"26100106"|"Maintenance Bldg"|"5004"|"04/19/2010"|"71 Lyell Avenue"|"Spencerport"|" 14559"|"ANNUAL"|"09/01/2011"|"1952"|"9176"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"0"|"0"|"3"|"500"|"S"|"1982"|"7"|"0"||"1"|"MUN_UTILIT"|"S"|"1952"|"5"|"33,134."|"Replace water service from Administrative Building to Maintenance Building."|"1"|"MUN_UTILIT"|"S"|"1952"|"5"|"67,757."|"Replace samitary lateral to Lyell Avenue."|"1"|"S"|"1952"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1952"|"10"|"0"|"Equipment appears to be in good working order. May be fed from another building - no pad mounted or pole mounted transformer observed. "|"1"|"S"|"1952"|"10"|"0"||"1"|"S"|"1952"|"10"|"0"||"1"|"S"|"1952"|"10"|"0"||"1"|"S"|"1952"|"10"|"0"||"1"|"MUNI"||"1"|"S"|"1952"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"132,278."|"Crack fill and seal all pavements not scheduled for improvement. Spot repair, mill and pave 200 sq. ft. of parking lot. Remove and repave strip along grass in west parking lot. "|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1952"|"20"|"0"||"1"|"S"|"1952"|"20"|"0"||"1"|"S"|"1952"|"20"|"43,065."|"Repair stained walls after roof is fixed. "|"1"|"U"|"1952"|"2"|"42,323."|"Due to roof leaks, ceilings need to be repaired."|"0"||||"0"||"1"|"S"|"S"|"1982"|"6"|"0"||"1"|"S"|"1962"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1952"|"32"|"23,288"|"Replace fused switchboard with circuit breaker panelboard. "|"1"|"S"|"1952"|"5"|"0"|"Variety of flourescent and some HID fixtures. Some have supplemented original units. "|"1"|"0"|"S"|"1952"|"5"|"0"|"No PA or intercom syste in place. Only phones. Requirements are minimal."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"U"|"1952"|"5"|"13,163."|"Replace delaminated tiles."|"1"|"COMMON"|"U"|"1952"|"5"|"8,100"|"Concrete floors are spalling and cracked. Need to be repaired. "|"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"1"|"0"|"0"|"1"||"0"|"0"|"0"|"U"|"1952"|"5"|"1,134"|"Wood mezzanine floor needs rim plates and bridging. "|"MASONRY,WOOD"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"U"|"1952"|"5"|"13,419."|"Wood siding and facia are rooting at west wall. Some cracks in CMU walls. "|"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1982"|"2"|"28,661."|"Overhead doors need to be replaced. Repair spalled concrete at hollow metal door. "|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1952"|"4"|"20,412."|"Windows are single glazed. Replace with insulated glass units. "|"METONMET,WOODONWOOD"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"1"|"1"|"1"||"U"|"1982"|"1"|"295,215."|"Roof is beyond expected life and needs to be replaced. "|"0"|||||"0"||"1"|"COPPER"|"S"|"1982"|"10"|"4,860."|"Add RPZ. "|"1"|"IRON,COPPER"|"S"|"1982"|"10"|"34,776."|"Trench drains need reair and need oil separator. "|"1"|"NAT_GAS"|"S"|"1982"|"5"|"0"||"1"|"S"|"1982"|"10"|"0"||"0"||"1"|"FURNACE"||"S"|"2008"|"10"|"0"||"1"|"S"|"1982"|"10"|"0"||"0"||||"0"||"1"|"S"|"1982"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1982"|"10"|"0"|"System appears to be newer than original building."|"1"|"S"|"1982"|"10"|"0"||"0"||||"0"||"1"|"S"|"1982"|"10"|"0"|"Emergency lighting handled with battery pack units. Layout appears adequate. "|"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"||"1"|"OTHER"||"0"|"0"|"40399"|"Repair walls and ceiling which have been damages by roof leaks. "|"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"815,448."|"U"|"1"|"LaBella Associates, P.C."|"300 State Street, Suite 201, Rochester, New York 14614"|"585-454-6110"|"mshort@labellapc.com"|"Michael E. Short"|"032717"|"I ACCEPT"|12/15/2010 1:23:10 PM| 264|"Falconer CSD"|"06110104"|"Fenner Elementary School"|"0002"|"07/13/2010"|"2016 East Main Street"|"Falconer"|" 14733"|"ANNUAL"|"08/01/2011"|"1956"|"52,588"|"1"|"2"|"3"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"|"Athletics and Extracurricular"|"259"|"3,4,5"|"0"|"1"|"0"|"259"|"0"|"0"|||"17"|"14,450"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1995"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"3"|"100,000"|"Excluding the blacktop that was replaced in 2005, all other needs to be milled, resurfaced, sealed and restriped."|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"5"|"20,000"|"Portions of sidewalk and curb need repair or replacement. Asphalt walk (north) needs repair or replacement. South canopy pad needs repair. "|"1"|"S"|"2000"|"5"|"20,000"|"Some portions of play equipment are wood. Replace grade surface which is sitll wood chips."|"1"|"S"|"2000"|"10"|"3,000"|"N"|"One small baseball backstop needs new fabric."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"10"|"75,000"|"Ceilings in the 1989 wing are showing considerable cupping. Corridor tectum ceiling in 1989 wing shoiwng considerable staining."|"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"S"|"2000"|"15"|"15,000"|"Hardware in 1989 wing needs to be upgraded to ADA "|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"3"|"35,000"|"Many T-12 lamps and ballasts need to be replaced in classrooms and toilet rooms. "|"1"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"8,000"|"Some VAT needs to be abated."|"1"|"COMMON"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"15"|"5,000"|"Planters need to have the stone caps reset and cleaned, some other stone sills and fascia need to be cleaned."|"1"|"MASONRY"|"S"|"2005"|"15"|"0"||"1"|"MASONRY"|"S"|"2005"|"15"|"0"||"S"|"S"|"1"|"1"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"15"|"0"||"METONMET"|"BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"5"|"430,000"|"1989 wing needs to be replaced."|"1"|"PLASTIC"|"S"|"2005"|"5"|"0"||"1"|"COPPER"|"S"|"1996"|"15"|"0"||"1"|"IRON"|"S"|"1996"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"5"|"10,000"|"The hot water heater is approaching the age where it should be replaced."|"1"|"S"|"1996"|"5"|"10,000"|"Water closet and urinal flush valves and water closet seats need to be upgraded to automatic flush valves."|"0"||"1"|"BOILERWATE"||"S"|"1996"|"3"|"140,000"|"1986 boiler is nearing end of expected useful life and the boiler and associated factory installed piping, trim and burner should be considered for replacement."|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"1"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"1"|"1"|"0"|"0"||||"1"||"GOOD"||"871,000"|"E"|"1"|"Harrington Sandberg Architecture and Engineering, P.C."|"500 E Sixth St., Jamestown, NY 14701"|"716-483-3153"|"mb@harringtonsandberg.com"|"Ronald I. Kessler, R.A."|"023043"|"I ACCEPT"|12/15/2010 2:04:15 PM| 265|"Norwich City SD"|"08120005"|"Stanford Gibson Primary School"|"0002"|"03/04/10"|"RIDGELAND ROAD "|"NORWICH "|" 13815"|"ANNUAL"|"12/01/2010"|"1955"|"78,115"|"1"|"6"|"1"|"DISTRICT"|"INSTRUCT"||"452"|"Pre-K,K,1,2"|"0"|"1"|"1"|"452"|"0"|"0"|||"34"|"27,543"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,RSRCEROOM,SCIENCELAB"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1988"|"8"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"5"|"$35,000"|"Replace service as life expectancy is coming to an end. OUtside of building footprint only. Add backflow prevention on service."|"1"|"MUN_UTILIT"|"S"|"1995"|"10"|"0"||"1"|"S"|"1998"|"18"|"0"|"No work needed for Natural Gas Service."|"1"|"UTIL"|"BELOW"|"S"|"2002"|"42"|"0"||"1"|"S"|"2001"|"10"|"$30,000"|"Storm Drainage required for side pakring area."|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"30"|"0"||"0"||||"0"||"1"|"MUNI,SURFACEH2O"||"1"|"S"|"2001"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"5"|"$153,000"|"Add. parking reqrd,expand E. lot. Replace paving @ E. lot. Provide crack filler, asphalt sealant & new like striping @ all asphalt drives & parking to front of school. Replace damaged concrete curb and paving @ parant drop-off."|"1"|"CONCRETE,ASPHALT"|"S"|"2010"|"30"|"$29,000"|"Replace sidewalk at parent drop off. Replace/Install new sidewalk at East lot."|"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"1955"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"50"|"0"||"0"|"S"|"1955"|"48"|"$101,200"|"Remove insul. backed pegboard/consider tackable acoustic. Reskin chalkboards to whiteboards in 6 rooms. Replace casework wardrobe clsrm 4024. Rebuild damaged masonry wall in corr. 4095. Replace toilet partitions in Boys room near locker rooms."|"1"|"S"|"2002"|"17"|"$8,500"|"Secondary corridor, health ste, address source of water damaging ceiling tiles - abondoned skylight or HVAC related. Hard ceiling vestibule 4116 spalling, needs replacement. Replace ceiling in corr. 4041A."|"1"|"U"|"1955"|"2"|"$50,000"|"Existing corridor lockers are "wardrobe style" and double tier very narrow and appear to be used for book storage and not student use. Consider replacing with larger units that will accept student clothing and backpacks."|"1"|"S"|"S"|"1955"|"10"|"$46,300"|"Wireglass replaced in areas with potential of injury. Provide ADA signage. Replace door closers, smoke doors & kick plates in cafeteria/corridor. Replace doors @ lobby to aud. corridor 4069, overhead door @ gym, and toilet room 4039."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1955"|"2"|"$695,000"|"Replace original panelboards. Add lighting panelboards, remove circuit braekers serving @ ea clsrm. Provide diesel standby generator w subbase fuel tank. Replace cloth wire. Provide add. convenience receptacles in most clsrms."|"1"|"S"|"2008"|"18"|"$216,000"|"Replace clsrm lighting. Add occupancy sensors. Replace high-bay luminaires utilizing metal-halide lamps w/ energy saving high-bay flourescent luminaires in the gym. Replace incandescent lighting in storage rooms."|"1"|"1"|"S"|"2008"|"23"|"$639,500"|"Add ADA assistive listening. Remove existing unused telecomm. cable not tagged for future use, from source to termination. Updates to security-serveillance,computer network cabling system, video dist., servers, network hardware, telephone system."|"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"$2,500"|"Cracked VCT between corridor 4001 & corridor 4009, Replace."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"$6,000"|"Ceramic tile in vestibules 4116 & 4018A are missing grout and tile due to salt corrosion. Replacement is needed."|"1"|"COMMON"|"S"|"2008"|"10"|"$5,800"|"Refinish stage floor - paint back 1/2 black."|"SLABGRADE,OTHER"|"Reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2002"|"50"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"1"|"1"|"1"||"S"|"2002"|"30"|"$26,500"|"Repoint/reconstruct brick. Surface prep/paint lintels. Add additional brick expansion joints to prevent future cracking, re-caulk existing. Caulk gap above UV louver clsrm 4002. Flash & caulk retaining wall cap."|"1"|"MASONRY"|"S"|"2007"|"72"|"$5,000"|"Remove & replace lead cap, clean masonry."|"0"|||||"0"||"S"|"S"|"1"|"1"|"2002"|"31"|"$9,600"|"Add weather seal @ kitchen & Cafeteria perimeter, when rains water entry. Replace rusted threshold @ library exterior door. Add door from auditorium to exterior, may require removal of some seating, floor finish work."|"1"|"E"|"2010"|"30"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"U"|"Y"|"1955"|"1"|"$432,000"|"Replace original exterior windows (except for ones in 2002 additions)."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"12"|"$3,000"|"Wind causes water to spill over cafeteria roof edge at trash area by kitchen and front entrance. Verify cause/add roof drain?"|"1"|"PLASTIC"|"S"|"2002"|"12"|"0"|"See comment #65."|"1"|"GALVANIZED,COPPER"|"S"|"1955"|"5"|"$217,500"|"Replace original water mains in 1955 building. Add backflow prevention to water service inside building footprint. Upgrade existing gate valves with new ball type valves."|"1"|"IRON,GALVANIZED"|"S"|"1955"|"5"|"$15,000"|"Replace all galvanized sanitary waste and vent piping. Provide study of existing piping to determien condition of piping."|"1"|"OIL,OTHER"|"S"|"1955"|"2"|"$39,000"|"Replace existing hot water storage tanks & repipe. Replace oil fired summer water heater w/ nutural gas fired tank type water heater w/ large recovery."|"1"|"S"|"2008"|"10"|"$21,300"|"Remove spitoon & fountains from gym, infrill w/ wall pads. Upgrade kitchen dishwash spray faucet. Replace mop sink faucets. Upgrate toilets near Nurses office w/ ADA fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"E"|"2008"|"23"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"S"|"2001"|"11"|"0"||"0"||||"0"||"1"|"S"|"2001"|"21"|"$780,000"|"Provide heating & ventilation air to 1989 addition. Upgrade controls to clrsm supply fans typ of 3 & provide high efficiency motors. Replace auditorium air handlers w/ rooftop units. Replace gym air handlers w/ roof units."|"1"|"S"|"2008"|"48"|"0"|"2008 capital project replace the entire piping system and reconnected to the existing equipment."|"1"|"S"|"2001"|"41"|"0"|"The original 1955 ductwork is sstill in place and was cleaned in the 2008 capital project. No issues with teh ductwork were reported at that time."|"1"|"S"|"2010"|"20"|"$22,000"|"Provide fire alarm notification appliances in all spaces occupied by 2 or more people. Fire alarm control panel being replaced under current Capital Project."|"1"|"S"|"1990"|"1"|"$204,000"|"Replace conventional fire alarm initiation devices w/ addressable devices. Includes wiring replacement with new FPLP cabling to improve system reliability. Missing manual pull stations at various locations."|"0"|"S"|||"$20,000"|"Stage Sprinklers: Provide an automatic fire sprinkler system in the Auditorium stage area (limited service off domestic water service.)"|"1"|"S"|"2008"|"12"|"$8,800"|"Add Exit sign at Cafeteria 4048, Locker Rooms and Kitchen 4038. Provide emergency lighting in Kitchen, Locker Rooms and Gymnasium."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"FAIR"|"Consider replacing hard plaster classroom ceiling w/ acoustic ceiling systems for sound absorption and above ceiling utility accessibility. Cost: $135,000"|"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Shower areas (mold), Area B water damage stains"|"1"|"OTHER"|"Stale air quality (not mold odor) noticed in student Toilet Rooms. Possibility of mold behind peg board in classrooms."|"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"0"||"FULL"|"0"|"1"||"GOOD"||"$4,922,450"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road Ithaca New York 14850"|"607-277-7100"|"info@tetratech.com"|"Barbara Chambers"|"024424"|"I ACCEPT"|12/15/2010 2:07:14 PM| 266|"Alden CSD"|"14010106"|"Alden Blockhouse"|"7016"|"01/14/2010"|"11187 Broadway"|"Alden, New York"|" 14004"|"ANNUAL"|"12/01/2010"|"1950"|"3500"|"1"|"0"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1961"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"15"|"0"||"1"|"S"|"1961"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1950"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1950"|"10"|"0"|"Minor Cracking"|"1"|"ASPHALT"|"S"|"2001"|"5"|"0"|"Some cracking, but minor"|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"10"|"0"|"Some chipping"|"1"|"S"|"1950"|"20"|"0"||"1"|"S"|"1950"|"20"|"0"||"1"|"S"|"1950"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1950"|"10"|"0"||"1"|"S"|"1950"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1950"|"15"|"0"|"Some wiring has cloth wrap insulation that should be replaced."|"1"|"S"|"2001"|"7"|"0"||"1"|"1"|"S"|"1950"|"7"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"7"|"0"||"1"|"COMMON"|"S"|"1950"|"7"|"0"||"1"|"COMMON"|"S"|"1950"|"7"|"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1950"|"10"|"0"||"1"|"MASONRY"|"S"|"1950"|"50"|"0"|"Recommended screen cap at top of chimney"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"10"|"0"|"Some scratches and dents in doors"|"1"|"S"|"1950"|"10"|"0"||"0"|||||"0"||"1"|"STEEL,VINYL,OTHER"|"S"|"NA"|"2001"|"15"|"0"||"WOODONMET"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"20"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1950"|"10"|"0"|"Piping not insulated or identified"|"0"|"PVC"|"U"|"1961"|"3"|"0"|"No control or alarm panel installed and no cover on sump basin"|"1"|"NAT_GAS"|"S"|"1989"|"5"|"0"||"1"|"S"|"1961"|"7"|"0"||"1"|"CV"|"0"||||||"0"||"0"||||"0"||"1"|"S"|"2001"|"10"|"0"|"Condensing unit for furnace in outside"|"0"|"S"|"1950"|"10"|"0"||"0"||||"0"||"1"|"S"|"1950"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"U"|"2005"|"3"|"5000"|"Battery operated smoke detectors throughout the building are not-reporting"|"0"||||"0"||"1"|"U"|"2005"|"3"|"525"|"No emergency lighting fixtures, exit signs are non-illuminated"|"0"||||"0"||"0"|"0"|"0"|"Current building does not allow for handicap accessibility for a wheelchair, however the building use does not require accessibility because it is a residential structure.Cost associated is UNKNOWN."|"GOOD"|"Building is used for district storage"|"FAIR"|"Some debris on carpet, but generally clean for storage use"|"0"|"0"|"FAIR"|"Acoustic panels in front conference room."|"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"|"No evidence of cold, moisture, or water penetration. Cost is UNKNOWN."|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"|"Ventiliation is not required for this residential space."|"0"|"0"|"1"|"1"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"14,819.40"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo NY, 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/15/2010 2:21:28 PM| 268|"Norwich City SD"|"08120005"|"Norwich High School"|"0008"|"03/03/2010"|"MIDLAND DRIVE "|"NORWICH CITY "|" 13815"|"ANNUAL"|"12/01/2010"|"1963"|"280,877"|"1"|"15"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"1158"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"1158"|"0"|"0"|||"64"|"48,524"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"2"|"10,000"|"E"|"2010"|"30"|"0"||"1"|"MUN_UTILIT"|"E"|"2008"|"50"|"0"||"1"|"MUN_UTILIT"|"E"|"2008"|"50"|"0"||"1"|"S"|"1963"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1963"|"3"|"60,000"|"Replace HS underground service entrance with new entrance conductors. Includes sawcutting, trenching, pavement patching and a spare 4" underground conduit."|"1"|"E"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"20,000"|"Miscellaneous drop inlet replacement (approx. 10)."|"0"||||"0"||"1"|"MUNI,SURFACEH2O,ONSITE"||"1"|"E"|"2008"|"30"|"0"||"1"|"E"|"2008"|"30"|"0"||"0"||||"0"||"0"||||"0"||"1"|"E"|"2008"|"30"|"0"||"1"|"ASPHALT"|"S"|"2008"|"13"|"255,000"|"Replacement of paving in front of HS including drives/parking lot NE of school. Provide crack filler, asphalt sealant and striping parking lot adjacent to baseball field. New asphalt around concession. New signage and pavement markings at parent drop-off."|"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"30"|"72,000"|"Provide misc. sidewalk work at HS. Sidewalk and curb replacement at bus drop-off. Reset granite curbing in areas of displacement (approx. 100 LF)."|"0"||||"0"||"1"|"S"|"2008"|"15"|"189,000"|"Y"|"Replace dust collector with chain link fence. Separate fields from parking with chain link fencing. Add irrigation systems to baseball/softball fields. Add portable bleachers. Reconstruct JV softball field, baseball field and pole vault runway"|"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"50"|"1,000"|"Classroom 2065, patch crack in foundation wall."|"1"|"S"|"2008"|"58"|"0"||"1"|"S"|"2008"|"58"|"1,867,640"|"Reskin chalkboards to be whiteboards, add/replace worn casework in various rooms. Replace ceramic tile. Replace toilet partitions. Masonry repointing at various areas."|"1"|"S"|"2010"|"25"|"304,000"|"Replace lay-in ceiling in Gym 2099. Replace hard tile ceilings with acoustic system. Install new grid ceilings locker areas. Replace ceiling in kitchen with acoustic system."|"1"|"E"|"2010"|"40"|"63,000"|"Replace boys and girls gym locker rooms lockers and benches."|"1"|"S"|"S"|"2010"|"13"|"194,250"|"Replace wire glass and sidelights. Replace various worn wood and metal doors. Provide closers on various doors. Replace interior doors in Vestibule 70. Replace gym folding partition."|"1"|"S"|"2008"|"55"|"0"||"0"||||"0"||"1"|"1"|"S"|"1963"|"3"|"1,374,000"|"Replace fusible switch, lighting panelboards, transformer. Provide additional receptacles in various classrooms. Replace gym scoreboards, Natatorium lane timing system, sound system, auditorium sound and portable track timing system."|"1"|"S"|"2008"|"18"|"601,800"|"Add occupancy sensors, emergency lighting. Replace luminaires in gyms, classroom lighting, auditorium lighting console and football field lighting. Illuminate auditorium aisles, tennis courts, concession stand area."|"1"|"1"|"S"|"2008"|"18"|"1,825,000"|"Provide surface raceway system and computer network hardware. Install new video distribution. Replace exstg telephone system. Provide telecomm. grounding system and UPS units. Add proximity card readers, intrusion detection and security cameras."|"1"|"S"|"2002"|"35"|"50,000"|"Replace pool deck drainage using piping better suited for the pool water."|"1"|"INSTRUCT"|"S"|"2008"|"18"|"3,000"|"Replace carpet in Room 8 with VCT."|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"20"|"153,000"|"Add casework at science room island. Replace VAT floors with VCT at various rooms."|"1"|"COMMON"|"S"|"2008"|"18"|"2,500"|"Add floor hatch for access to crawlspace in kitchen."|"1"|"INSTRUCT,COMMON"|"S"|"2008"|"18"|"27,000"|"Refinish wood floor stage apron and gym wood floor."|"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"1"|"S"|"2008"|"50"|"140,000"|"Rebuild concrete around pool floor vents. Remove structure and concrete walls in greenhouse (reached the end of their useful life). Remove and replace greenhouse window and masonry knee walls with flush windows and brick."|"MASONRY,STEEL"|"0"|"0"||"0"|"1"|"1"|"1"|"1"||"S"|"2008"|"30"|"23,050"|"Add flashing at Biology 48 window. Recaulk existing brick joints. Prep/paint lintels. Brick infill/repointing, efflorescence cleaning."|"1"|"MASONRY"|"S"|"1963"|"20"|"0"||"1"|"MASONRY"|"S"|"1976"|"25"|"0"||"E"|"E"|"1"|"1"|"2008"|"30"|"0"||"1"|"S"|"2008"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"21"|"241,800"|"Replace original 1980 windows. Replace 1987 cafeteria windows. Replace fogged glazing at HS Science Rooms 53, 54 and 55."|"METONMET,OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"15"|"1,000"|"Ladder between pool and gym; prep surface and paint. Weld platform."|"1"|"PLASTIC"|"E"|"2008"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"20"|"60,000"|"Replace existing galvanized water piping. Replace a number of gate valves in the water distribution piping."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"15"|"22,000"|"Provide drainage for ice machine in boys locker room, plaster traps in art rooms, grease traps in (3) bowl sinks in kitchen and direct waste connections for food prep sinks."|"1"|"NAT_GAS"|"S"|"2002"|"10"|"70,000"|"Replace hot water return main including piping, pump, hangers, insulation, etc."|"1"|"S"|"1963"|"5"|"213,000"|"Replace fixtures with water saving fixtures in several gang toilets, upgrade toilets to meet ADA requirements. Add eyewash; upgrade boiler room and (4) science rooms. Misc. sink trim replacement."|"0"||"1"|"BOILERWATE"||"S"|"2001"|"16"|"0"||"1"|"S"|"2001"|"11"|"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"2008"|"22"|"2,379,500"|"Replace exhaust hood at earth science lab. Replace classroom UVs, Gym AHUs, Cafe AHU, and kitchen ventilation. Provide positive ventilation for resource room. Upgrade pneumatic controls to DDC."|"1"|"S"|"2008"|"22"|"0"|"Piping cost to unit is incorporated into Item 78 with the replacement of equipment."|"1"|"S"|"2008"|"32"|"0"||"1"|"S"|"1963"|"2"|"0"|"The cost to replace pneumatics with DDC controls is incorporated into Item 78."|"1"|"S"|"2008"|"18"|"21,000"|"Provide fire alarm notification appliances in all spaces occupied by 2 or more people. "|"1"|"S"|"1990"|"2"|"220,000"|"Replace conventional fire alarm initiation devices with addressable devices, including wiring replacement with new FPLP cabling to improve system reliability."|"1"|"S"|"2006"|"2006"|"5,000"|"Kitchen exhaust hood fire suppression system."|"1"|"S"|"2008"|"18"|"0"||"1"|"E"|"2008"|"28"|"0"||"1"|"1"|"263,000"|"Renovate 2 boys and girls gang toilet rooms to be accessible. Home and Careers room does not have accessible work stations."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"SPOT"|"1"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,LIGHTING"|"FULL"|"0"|"1"|"0"|"GOOD"||"13,596,752"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Barbara Chambers"|"024424"|"I ACCEPT"|12/15/2010 2:40:48 PM| 270|"Chappaqua CSD"|"66100406"|"Douglas Grafflin Kindegarten"|"0002"|"08/17/2010"|"650 King Street"|"Chappaqua"|" 10514"|"ANNUAL"|"08/01/2011"|"1962"|"4300"|"1"|"0"|"1"|"DISTRICT"|"INSTRUCT"||"42"|"K"|"0"|"1"|"0"|"42"|"0"|"0"|||"2"|"2000"|"OTHER"|"Kindergarten"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"10"|"20000"|"Add RPZ backflow preventer"|"1"|"MUN_UTILIT"|"S"|"1962"|"10"|"0"|"No obvious or reported problems"|"1"|"S"|"1962"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1962"|"10"|"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"6"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1962"|"6"|"0"||"1"|"S"|"2003"|"6"|"0"||"1"|"S"|"1962"|"6"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"6"|"0"||"1"|"S"|"1962"|"6"|"0"||"1"|"S"|"1962"|"6"|"0"||"1"|"S"|"1998"|"6"|"0"||"0"||||"0"||"1"|"S"|"S"|"1962"|"6"|"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"15"|"0"|"Replacement/upgrade of electrical distribution equipment should be considered during next major renovation/addition"|"1"|"S"|"1996"|"10"|"500"|"Replace downlight bulbs in basement with CFL lamps. Consider lighting replacement during next major renovation"|"1"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2001"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL,OTHER"|"castinplace concrete slab on concrete frame"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"6"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"1"|"1"||"S"|"1962"|"6"|"0"||"1"|"METAL"|"S"|"1962"|"6"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1962"|"6"|"0"||"1"|"S"|"1962"|"6"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1962"|"6"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"7"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1962"|"10"|"0"|"No apparent or reported problems"|"1"|"IRON,COPPER"|"S"|"1962"|"10"|"0"|"No apparent or reported problems"|"1"|"NAT_GAS"|"S"|"2004"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1996"|"0"|"0"|"Boiler is scheduled to be replaced during already-funded energy performance contract at SED awaiting approval"|"1"|"S"|"2003"|"6"|"0"||"1"|"S"|"2003"|"5"|"0"|"Window units in each classroom"|"0"||||"0"||"0"|"S"|"1962"|"5"|"0"|"No apparent or reported problems, but periodic preventive maintenance required"|"0"||||"0"||"1"|"S"|"1962"|"3"|"0"|"Controls will be replaced as part of pending energy performance contract"|"1"|"E"|"1999"|"10"|"8000"|"Add visual alarm devices in classrooms and toilet rooms"|"1"|"E"|"1999"|"15"|"0"||"1"|"S"|"1999"|"1999"|"0"|"Ansul chemical system in kitchen hood; portable fire extinguishers in building"|"0"|"S"|"1999"|"5"|"10000"|"Additional emergency light fixtures needed in hallways"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"|"0"|"GOOD"||"40500"|"S"|"0"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"cblack@kgdarchitects.com"|"Calvin L. Black, PE"|"078642"|"I ACCEPT"|12/15/2010 2:47:29 PM| 271|"Alden CSD"|"14010106"|"Alden Bus Garage"|"5001"|"01/14/2010"|"1648 Crittenden Road"|"Alden, New York"|" 14004"|"ANNUAL"|"12/01/2010"|"1951"|"9600"|"1"|"0"|"0"|"DISTRICT"|"OTHER"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"10000"|"1"|"5000"|"S"|"1999"|"10"|"0"||"1"|"MUN_UTILIT"|"U"|"2001"|"5"|"15000"|"No meter or backflor preventor. Low pressure reported when bus washing and fixtures used simultaneously."|"1"|"MUN_UTILIT"|"S"|"1951"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"|"Interior piping is not painted or identified"|"1"|"OTHER"|"BELOW"|"E"|"1999"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1951"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2001"|"3"|"0"|"Suggest repaving in bus loop area. Bus traffic is deteriorating surface"|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"15"|"0"|"Minor cracking"|"0"||||"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"|"Some sagging of ACT and soiling based on building use and lack of ventilation or conditioning."|"0"||||"0"||"1"|"S"|"S"|"2001"|"10"|"0"||"1"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"2007"|"7"|"0"|"Lenses yellowed and multiple lamp temps"|"1"|"1"|"U"|"1999"|"5"|"5000"|"Data rack located above ceiling and no access"|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"7"|"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"1997"|"15"|"0"||"OTHER"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1951"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"||"1"|"MASONRY"|"S"|"1950"|"15"|"0"|"Unknown if chimney used for heat. If not used, remove in entirety and cap penetration. If used, screen add acreen at top."|"1"|"MASONRY"|"S"|"1951"|"3"|"0"|"Minor step crack in masonry at various locations. Repointing affected areas required."|"S"|"S"|"0"|"1"|"2001"|"10"|"0"||"0"|"S"|"1951"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL,OTHER"|"S"|"NA"|"2001"|"10"|"0"|"Paint is chipped on steel windows and they are in need of a cleaning."|"WOODONWOOD,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"7"|"0"|"Staff reported minor leaking around roof penetrations."|"0"|||||"0"||"1"|"COPPER"|"U"|"2000"|"1"|"20000"|"Some insulation missing. No identification and pressure problems reported when washing buses."|"1"|"IRON"|"U"|"2000"|"3"|"35000"|"Poor drainage reported in bus repair and wash bays"|"1"|"NAT_GAS"|"U"|"1998"|"1"|"20000"|"Reported that recovery is insufficient when washing buses"|"1"|"S"|"1951"|"5"|"0"||"1"|"CV"|"0"||||||"0"||"0"||||"0"||"1"|"U"|"2005"|"5"|"350"|"Window AC unit in office area"|"1"|"U"|"2001"|"3"|"8500"||"0"||||"0"||"1"|"U"|"1951"|"5"|"5000"|"Ceiling mounted unit is undersized and never replaced during previous renovations."|"0"||||"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"E"|"2007"|"10"|"0"||"0"||||"0"||"1"|"NF"|"1999"|"3"|"2625"|"No illuminated exit signs directing occupants to building exits, only one non-illuminated exit sign in building."|"1"|"E"|"2008"|"15"|"0"||"1"|"0"|"1500"|"Restroom facilities do not meet accessibility requirements"|"GOOD"||"GOOD"|"Some water doesn't drain to center of floor in bay"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"||"No evidence of mold present. Wet areas of building contain building materials that do not support the growth of mold."|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Some exhaust fumes throughout the building, exhaust tube in garage doors for venting"|"0"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"|"0"|"GOOD"||"$114,100.00"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/15/2010 3:15:14 PM| 275|"Alden CSD"|"14010106"|"High School"|"0014"|"01/07/2010"|"13190 Park Street"|"Alden, New York"|" 14004"|"ANNUAL"|"12/01/2010"|"1964"|"161,820"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"662"|"9,10,11,12"|"0"|"0"|"1"|"662"|"0"|"0"|||"50"|"40,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"10"|"0"|"Service shut-off valve rusting"|"1"|"MUN_UTILIT"|"S"|"1961"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"|"Piping not painted"|"1"|"UTIL,OTHER"|"BELOW"|"S"|"2001"|"7"|"0"|"Lens are yellowed and would need replacement"|"0"||||"0"||"0"||||"0"||"1"|"S"|"1961"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"15"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2001"|"10"|"0"|"Asphalt needs crack repairs and sealing"|"0"||||"0"||"1"|"U"|"2008"|"3"|"328,975"|"N"|"Deep standing water at second base and first base. Noticeable bald patches in fields"|"MASONCON"|"0"|"0"|"1"|"0"|"0"|"0"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"|"Cracking above door head in drywall"|"1"|"S"|"2002"|"10"|"0"|"Numerous water stained and chipped tiles"|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"S"|"2001"|"7"|"0"||"1"|"S"|"1964"|"20"|"0"|"Storage under stairs is a code violation. Stairs not in a rated enclosure."|"1"|"S"|"1992"|"20"|"0"||"1"|"1"|"E"|"2002"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"1"|"U"|"2009"|"5000"|"3"|"Need Removal and clean-up of obsolete parts of old and new phone system."|"1"|"S"|"1964"|"15"|"0"|"Life expectancy of the pool filters is only a year or two due to the failure of the internal components."|"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2009"|"10"|"0"|"Some cracking of terrazzo above crawl space area - suggest replacement of tiles."|"1"|"COMMON"|"S"|"1964"|"10"|"0"||"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2001"|"20"|"0"|"Cracks in structural floor are believed to be at intersection of slab on grade and crawl space connection"|"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"||"1"|"MASONRY"|"U"|"1964"|"3"|"6000"|"Repointing recommended at top. Recommend stainless steel cap to block weather"|"0"|"METAL"|"S"|"2001"|"10"|"0"||"S"|"S"|"1"|"1"|"2001"|"10"|"0"|"Weatherstripping needs to be replaced."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1998"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"||"U"|"2001"|"5"|"$1,198,400"|"Severe rust of metal deck. Several damaged ceiling tiles located inside U-joists"|"1"|"PLASTIC"|"U"|"2001"|"5"|"0"|"Rot/Decay/Corrosion and evidence of water penetration/active leaks. Cost to replace unknown."|"1"|"COPPER"|"S"|"2003"|"10"|"0"|"Piping is not insulated"|"1"|"IRON,GALVANIZED"|"S"|"2001"|"10"|"0"|"No control or alarm panel installed"|"1"|"NAT_GAS"|"S"|"2001"|"5"|"0"||"1"|"S"|"2009"|"7"|"0"|"Column shower drains do not meet current code"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2002"|"10"|"0"|"Leaks at pumps"|"1"|"S"|"2002"|"15"|"0"|"Co-gen plant"|"0"|"S"|"1997"|"7"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"1961"|"5"|"0"||"0"||||"0"||"1"|"U"|"1961"|"3"|"0"|"Recommend converting pneumatic areas to ddc"|"1"|"E"|"2001"|"10"|"0"||"1"|"E"|"2001"|"10"|"0"||"1"|"S"|"2001"|"2001"|"0"|"Kitchen fire suppression hoods"|"1"|"S"|"2009"|"10"|"0"|"Exit lighting is old and exceeds useful life"|"1"|"S"|"2001"|"10"|"0"||"1"|"1"||"There are accessible interior and exterior routes."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"No acoustical wall panels or ceiling in gym-insulation may improve sound quality."|"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|"0"|"No evidence of mold, moisture or water penetration."|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||"0"|"0"|"0"|"1"|"LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"$1,953,261.00"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/15/2010 4:16:50 PM| 276|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG 5 INSTR MAINT "|"0005"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1967"|"9180"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT"||"43"|"10,11,12"|"0"|"1"|"0"|"43"|"0"|"0"|||"3"|"8665"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"|"Municipal provision for building isolation required."|"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"20,000"|"Municipal"|"1"|"S"|"1972"|"5"|"0"|"Provisions for building isolation required."|"1"|"UTIL"|"BELOW"|"S"|"1972"|"5"|"10,000/30,000"|"Underground primary pad mount/repalce existing transformers."|"0"||||"0"||"1"|"S"|"1967"|"5"|"0"||"1"|"S"|"1967"|"5"|"30,000"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1967"|"5"|"20,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"40,000"|"Slurry seal in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Slurry seal in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"5"|"86,500"|"Toilet room renovations."|"1"|"S"|"1968"|"5"|"8,000"|"Acoustical lay-in ceiling tiles."|"0"||||"0"||"1"|"S"|"S"|"1968"|"5"|"10,000"|"Vestibule doors need replacement."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"1968"|"2"|"0"|"Fluorescent T-12, non-electric ballast. "|"1"|"1"|"S"|"1968"|"4"|"20,000"|"Replace transformers. "|"0"||||"0"||"1"|"COMMON"|"S"|"1968"|"5"|"10,000"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"10"|"0"||"1"|"METAL"|"S"|"1972"|"5"|"0"||"0"|||||"0"||"E"|"E"|"1"|"1"|"2004"|"10"|"20,000"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2004"|"10"|"30,000"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"15"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"0"||"1"|"IRON,COPPER"|"S"|"1968"|"5"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"10"|"3,000"|"Not ASME, replace tank-less gas meter heater."|"1"|"S"|"1993"|"3"|"13,500"|"Upgrade toilet fixtures."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1994"|"10"|"0"|"Co-Ray Vac system."|"1"|"S"|"1994"|"5"|"0"||"1"|"S"|"2001"|"2"|"0"|"Window air conditioner."|"1"|"S"|"1994"|"5"|"0"||"1"|"S"|"1968"|"5"|"12,000"|"Rotary compressor/lead leg with existing compressor."|"1"|"S"|"1968"|"5"|"24,000"|"Vehicle exhaust."|"1"|"S"|"1968"|"3"|"10,000"|"Johnson Control System."|"1"|"E"|"2001"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"730,100"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/15/2010 4:34:21 PM| 277|"West Genesee CSD"|"42010106"|"Split Rock Elementary School "|"0005"|"7/27/10"|"4151 SPLIT ROCK RD "|"CAMILLUS "|" 13031-9722"|"ANNUAL"|"9/1/2011"|"1963"|"67,378"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"435"|"K,1,2,3,4,5"|"0"|"0"|"0"|"435"|"0"|"0"|||"32"|"28,042"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1971"|"35"|"$50,000"|"NO WORK PROPOSED"|"1"|"MUN_UTILIT"|"S"|"1971"|"35"|"$50,000"|"NO WORK PROPOSED"|"1"|"S"|"1971"|"35"|"$70,000"|"NO WORK PROPOSED"|"1"|"UTIL"|"BELOW"|"S"|"1971"|"35"|"$80,000"|"NO WORK PROPOSED"|"1"|"S"|"1971"|"20"|"$100,000"|"NO WORK PROPOSED"|"1"|"S"|"1971"|"10"|"$10,000"|"NO WORK PROPOSED"|"1"|"U"|"1971"|"5"|"$30,000"|"$30,000 WORK PROPOSED"|"1"|"S"|"1993"|"10"|"$10,000"|"NO WORK PROPOSED"|"1"|"MUNI,ONSITE"||"1"|"S"|"2005"|"20"|"$10,000"|"NO WORK PROPOSED"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"20"|"$195,000"|"$75,000 WORK PROPOSED"|"1"|"CONCRETE,ASPHALT"|"S"|"1971"|"10"|"$75,000"|"NO WORK PROPOSED"|"1"|"S"|"2002"|"20"|"$75,000"|"NO WORK PROPOSED"|"1"|"S"|"2005"|"20"|"$125,000"|"N"|"NO WORK PROPOSED - NEW SOCCER FIELD 2006"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"30"|"$4,000,000"|"NO WORK PROPOSED - SOME 1963 VINTAGE REMAINS"|"1"|"S"|"1993"|"15"|"$250,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$400,000"|"$18,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$520,000"|"$24,000 WORK PROPOSED"|"1"|"S"|"1993"|"5"|"$100,000"|"$15,000 WORK PROPOSED"|"1"|"S"|"U"|"2005"|"20"|"$150,000"|"$15,000 WORK PROPOSED - REPLACE NORTH WING HARDWARE"|"1"|"S"|"1971"|"20"|"$100,000"|"NO WORK PROPOSED - SOME 1963 VINTAGE REMAIN"|"1"|"S"|"1993"|"10"|"$100,000"|"NO WORK PROPOSED"|"1"|"1"|"S"|"1993"|"35"|"$69,000"|"$17,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$115,000"|"$48,000 WORK PROPOSED"|"1"|"1"|"S"|"1993"|"15"|"$8,000"|"$41,000 WORK PROPOSED - ASSISTED LISTENING IN CAFETERIA REMAINS."|"0"||||"0"||"1"|"COMMON"|"S"|"1993"|"5"|"$9,000"|"$8,000 WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1993"|"20"|"$112,000"|"$6,000 WORK PROPOSED"|"1"|"COMMON"|"S"|"1993"|"20"|"$50,000"|"$12,000 WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1993"|"20"|"$9,000"|"NO WORK PROPOSED"|"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"25"|"$2,000,000"|"NO WORK PROPOSED - SOME 1963 VINTAGE REMAIN"|"STEEL"|"0"|"0"||"1"|"1"|"0"|"0"|"1"||"S"|"1971"|"25"|"$6,000,000"|"$171,000 WORK PROPOSED - SEVERE PACK-RUST AT WINDOW LINTELS ON SOUTH FACE OF NORTH WING"|"1"|"MASONRY"|"S"|"1971"|"10"|"$100,000"|"$8,000 WORK PROPOSED TO EXTEND CHIMNEY"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1993"|"10"|"$85,000"|"$27,000 WORK PROPOSED"|"1"|"S"|"1971"|"25"|"$15,000"|"NO WORK PROPOSED"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1993"|"10"|"$1,500,000"|"$27,000 WORK PROPOSED"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"25"|"$213,000"|"NO WORK PROPOSED"|"1"|"PLASTIC"|"S"|"2005"|"25"|"$213,000"|"NO WORK PROPOSED"|"1"|"COPPER"|"S"|"1971"|"35"|"$55,000"|"$7,000 WORK PROPOSED"|"1"|"IRON"|"S"|"1971"|"35"|"$61,000"|"$3,000 WORK PROPOSED"|"1"|"NAT_GAS"|"S"|"1993"|"10"|"$10,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"10"|"$96,000"|"$126,000 WORK PROPOSED"|"1"|"DD_MZ"|"1"|"BOILERWATE"||"S"|"1993"|"15"|"$87,000"|"$87,000 WORK PROPOSED"|"1"|"S"|"1971"|"15"|"$9,500"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$200,000"|"$400,000 WORK PROPOSED"|"1"|"S"|"1993"|"25"|"$72,000"|"$30,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$50,000"|"$1,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$77,000"|"$1,000 WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$33,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"15"|"$51,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"10"|"$56,000"|"NO WORK PROPOSED"|"1"|"S"|"1993"|"1993"|"$10,000"|"NO WORK PROPOSED - A+ HOOD IN KITCHEN"|"1"|"S"|"1993"|"15"|"$30,000"|"NO WORK PROPOSED"|"0"||||"0"|"$67,000 WORK PROPOSED"|"1"|"1"|"4,000"|"PROVIDE ADA SIGNAGE"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"1,179,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"GOOD"||"$1,111,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/15/2010 4:38:57 PM| 279|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG 6 INSTR "|"0006"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1967"|"10962"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT"||"77"|"9,10,11,12"|"0"|"1"|"0"|"77"|"0"|"0"|||"3"|"4565"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"7,500"|"Drainage in shops."|"1"|"S"|"1972"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1972"|"5"|"10,000/30,000"|"Underground primary to pad mount/replace existing transformers."|"0"||||"0"||"1"|"S"|"1967"|"5"|"30,000"||"1"|"S"|"1967"|"5"|"30,000"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1967"|"5"|"20,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"20,000"|"Slurry seal in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Slurry seal in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"72,000"|"Toilet room renovations."|"1"|"S"|"1972"|"5"|"10,000"|"Lay-in acoustical."|"0"||||"0"||"1"|"S"|"S"|"1972"|"5"|"4,400"|"Re-keying and ADA hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"5"|"30,000"|"Electrical panel replacement."|"1"|"S"|"1972"|"2"|"0"|"Fluorescent T-12 with non-electric ballast."|"1"|"1"|"S"|"1968"|"1"|"20,000"|"Replace transformers."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"10"|"0"||"1"|"METAL"|"S"|"1972"|"5"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2004"|"5"|"22,500"|"Overhead door replacement."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2004"|"10"|"30,000"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"15"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"0"||"1"|"IRON"|"S"|"1972"|"5"|"7,500"|"Drainage system in shops."|"1"|"NAT_GAS"|"S"|"1996"|"2"|"3,000"|"Not ASMS, tank-less gas water heater."|"1"|"S"|"1993"|"3"|"27,500"|"Eyewash/hose reel and drinking fountains."|"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"1994"|"10"|"022,500"|"Co-Ray Vac System/Heating system improvements."|"1"|"S"|"1994"|"5"|"0"||"0"||||"0"||"1"|"S"|"1994"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"|"Gas piping."|"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"3"|"10,000"|"Johnson Control System."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"124,100"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/16/2010 9:18:07 AM| 282|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG 7 INST "|"0007"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1967"|"14158"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Occupational Education-Adult Education"|"40"|"9,10,11,12"|"0"|"1"|"0"|"40"|"0"|"0"|||"7"|"5910"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"|"Provisions for building isolation required."|"1"|"UTIL"|"BELOW"|"S"|"1972"|"5"|"20,000"|"Replace transformers."|"0"||||"0"||"1"|"S"|"1967"|"5"|"0"||"1"|"S"|"1967"|"3"|"30,000"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"3"|"10,000"|"Slurry seal in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"10,000"|"Slurry seal in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"1"|"S"|"1967"|"10"|"0"||"1"|"S"|"1967"|"10"|"0"||"1"|"S"|"1967"|"2"|"48,000"||"0"||||"0"||"1"|"S"|"S"|"1972"|"5"|"8,000"|"Re-keying and add hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"5"|"44,000"||"1"|"1"|"S"|"1972"|"1"|"2,000/20,000"|"Replace corrective clock/new PA system."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1967"|"5"|"40,000"||"1"|"INSTRUCT"|"S"|"1967"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"10"|"0"||"1"|"METAL"|"S"|"1994"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2006"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2006"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"15"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"5"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"13"|"3,000"|"Not ASME, replace with tank-less water heater."|"1"|"S"|"1993"|"5"|"34,000"|"Eyewash/semi-circular & circular wash fountains."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1994"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"10"|"0"||"1"|"S"|"1992"|"5"|"25,000"|"Replace air handler."|"1"|"S"|"1972"|"5"|"0"|"Gas piping."|"1"|"S"|"1972"|"5"|"0"||"1"|"S"|"1992"|"5"|"25,000"|"Replace temperature controls."|"1"|"S"|"1988"|"5"|"0"||"1"|"S"|"1988"|"5"|"0"||"0"||||"0"||"1"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"130,600"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/16/2010 10:14:50 AM| 284|"Weedsport CSD"|"05030104"|"High School"|"0002"|"08/03/2010"|"2821 East Brutus Street"|"Weedsport"|" 13166"|"ANNUAL"|"09/01/2011"|"1955"|"83085"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"419"|"7,8,9,10,11,12"|"0"|"1"|"1"|"419"|"0"|"0"|||"50"|"50940"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,POOL,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"7"|"88000"|"Match existing, approximate length of 600'"|"1"|"MUN_UTILIT"|"S"|"2001"|"20"|"0"|"New line from building to E. Brutus St. in 2001."|"1"|"S"|"2005"|"25"|"0"|"New gas line in 2005."|"1"|"UTIL"|"BELOW"|"S"|"2001"|"10"|"0"||"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"7"|"0"|"will need to remove sediment buildup in 7-10 years."|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"1968"|"5"|"75000"||"1"|"OTHER"|"Putnam Creek"|"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"12"|"0"||"1"|"CONCRETE"|"S"|"2004"|"12"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"253000"|"N"|"Replace tennis courts"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"20"|"10000"|"Firestopping required in electrical vault"|"1"|"S"|"2004"|"20"|"56000"|"Address cracks in 2004 wing."|"1"|"S"|"2004"|"5"|"384000"|"Replace ceilings in various locations in the 1955 and 1968 wings."|"1"|"U"|"2004"|"5"|"447000"|"Replace original lockers in 1955 and 1968 wings - nearing end of useful life."|"1"|"U"|"U"|"2004"|"5"|"696000"|"Replace doors and hardware throughout 1955 and 1968 wings."|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2005"|"5"|"26000"|"Replace panels in Boiler Room."|"1"|"S"|"2004"|"5"|"140000"|"T12s need to be replaced in offices located in 1955 wing and corridors."|"1"|"1"|"S"|"2004"|"5"|"830000"|"Replace PA and clock system. Add horizontal Cat 6 to classrooms."|"1"|"S"|"1968"|"5"|"875000"|"Replace drains, gutters, piping, and pool pump."|"1"|"COMMON"|"S"|"2004"|"10"|"18000"|"Recommend replacing Media Center carpet and expansion joint cover."|"1"|"INSTRUCT"|"S"|"2004"|"10"|"141000"|"Replace flooring in 1955 wing."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"20"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2004"|"25"|"38000"|"Address cracks in 2004 wing."|"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2004"|"25"|"151000"|"Repoint portions of 1955 and 1968 wings, replace control joints, patch cracks in pool wall"|"1"|"MASONRY"|"S"|"2005"|"15"|"40000"|"Repoint chimney."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"29000"|"Replace 3 exterior doors, and 3 overhead doors"|"1"|"S"|"2004"|"5"|"4000"|"Reconstruct step adjacent to cafeteria entrance"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"10"|"21000"|"Recommend windows are re-caulked."|"METONMET,CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"10000"|"Relocate scupper at 2004 wing canopy"|"1"|"PLASTIC"|"S"|"2010"|"20"|"0"||"1"|"COPPER"|"S"|"2004"|"15"|"88000"|"Replace isolation valves throughout building."|"1"|"IRON,COPPER,PVC"|"S"|"2004"|"10"|"52000"|"Replace sanitary piping at Pool Locker Rooms."|"1"|"NAT_GAS"|"S"|"2008"|"15"|"88000"|"Replace pool heater. Building HW via storage tank with heat exchanger served by boilers."|"1"|"S"|"2004"|"10"|"218000"|"Replace original fixtures in 1955 wing."|"1"|"CV"|"1"|"BOILERWATE,BOILERSTEA,OTHER"|"Unit Ventilation"|"S"|"2006"|"5"|"350000"|"Replace steam boilers with hot water."|"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"2004"|"10"|"0"|"DX cooling around building."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"25"|"321000"|"Replace steam with hot water."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"16"|"175000"|"Replace control system."|"1"|"S"|"2004"|"5"|"280000"|"Simplex zone system, replace with addressable system with classroom strobes."|"1"|"S"|"2004"|"5"|"70000"|"Replace zone devices with addressable devices."|"1"|"S"|"2004"|"2004"|"0"|"Kitchen ansul system on hood. Sprinklers protect stage (1968 install)."|"1"|"S"|"2004"|"5"|"18000"|"Add to 2nd floor corridor."|"1"|"U"|"1955"|"0"|"192000"|"Provide 100kw outdoor generator with standby and emergency branches; recircuit emergency lighting."|"1"|"1"|"560000"|"Renovate toilet rooms in 1955 wing and Nurse's Office (Toilet Room)"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"INACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"FIREALARM,LIGHTING"|"FULL"||"1"||"GOOD"||"6753000"|"U"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/16/2010 10:42:26 AM| 287|"North Colonie CSD"|"01062306"|"Maplewood Annex"|"0031"|"06/18/2010"|"Easy Street"|"Watervliet"|"12189"|"ANNUAL"|"01/01/2011"|"1945"|"3150"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Custodial office and storage"|"0"|"UNGRD"|"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1945"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1945"|"10"|"0"||"1"|"S"|"1974"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2005"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"MUNI"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"10"|"0"|"Poured in 1997, drain infill in 2001."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1945"|"20"|"0"||"1"|"S"|"1945"|"15"|"0"|"Review garage walls/ceiling for fire rating requirements."|"1"|"S"|"1945"|"15"|"0"|"Office partition constructed 2009."|"1"|"S"|"2009"|"5"|"41,000"|"Spline ceiling at storage missing tiles. Holes at garage plaster, possible abatement."|"0"||||"0"||"1"|"S"|"S"|"1945"|"10"|"0"|"Office doors installed in 2009."|"1"|"S"|"1945"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2009"|"10"|"20,000"|"Office and storage fixtures replaced in 2009 and 2005. Original T12s in basement toilets."|"1"|"1"|"S"|"2009"|"15"|"0"|"Telephone upgrade 2009, no PA. "|"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"15"|"0"|"Offices."|"1"|"COMMON"|"S"|"1945"|"10"|"0"|"Original VAT in corridor and stairwell."|"1"|"COMMON"|"S"|"1945"|"15"|"0"|"Concrete at toilets, garage and basement."|"1"|"COMMON"|"S"|"1945"|"15"|"0"|"Wood strip floor at storage."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1945"|"15"|"0"|"Over basement area, assumed construction concealed with plaster."|"MASONRY"|"0"|"0"||"1"|"1"|"1"|"1"|"1"||"S"|"1945"|"10"|"75,000"|"Veneer stone stucco has cracking - needs repairing, $75,000 budget to wrap with new siding."|"1"|"MASONRY"|"S"|"1945"|"10"|"0"||"1"|"MASONRY"|"S"|"1945"|"10"|"0"|"Cracks at coping, mildew staining on north wall, refer to Item #65-Roofing."|"S"|"S"|"0"|"1"|"2009"|"15"|"0"|"Aluminum main door, HM side, metal overheads."|"1"|"S"|"2005"|"5"|"30,000"|"Side egress steps should be removed and rebuilt with railings."|"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1945"|"5"|"87,000"|"Replace original broken single pane."|"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"0"|"0"||"S"|"2001"|"10"|"0"|"SPF recoat in next 10 years. New flashing caps at parapet."|"0"|||||"0"||"1"|"COPPER"|"S"|"2005"|"5"|"0"||"1"|"IRON"|"S"|"1945"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1989"|"10"|"0"||"1"|"U"|"1945"|"5"|"0"|"Broken urinal, piping, floor repairs."|"0"||"1"|"BOILERWATE"||"S"|"1999"|"10"|"0"|"Consider improve combustion air."|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2009"|"15"|"0"|"Office split system installed 2009."|"1"|"S"|"1945"|"20"|"0"|"Review exhaust to storage and garage."|"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"S"|"1999"|"5"|"0"|"Older exit signs and coverage may not be adequate."|"0"||||"0"||"1"|"1"|"45,000"|"Toilet clearances, fixtures."|"FAIR"|"Broken windows, cracks in veneer."|"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"||"GOOD"|"Adequate for custodial office/storage."|"373,000"|"S"|"1"|"CSArch"|"40 Beaver Street, Albany, NY"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I accept"|12/16/2010 11:15:32 AM| 288|"West Genesee CSD"|"42010106"|"West Genesee Middle School"|"0009"|"7/27/10"|"500 Sanderson Drive"|"Camillus"|"13031-1698"|"ANNUAL"|"9/1/2011"|"1958"|"125,700"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"696"|"6,7,8"|"0"|"1"|"0"|"696"|"0"|"0"|||"49"|"48,534"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1958"|"15"|"$172,000"|"NO WORK PROPOSED"|"1"|"MUN_UTILIT"|"S"|"1958"|"15"|"$377,000"|"NO WORK PROPOSED"|"1"|"S"|"1958"|"15"|"$73,000"|"NO WORK PROPOSED"|"1"|"UTIL"|"BELOW"|"S"|"1958"|"10"|"$92,000"|"$38,000 WORK PROPOSED"|"1"|"S"|"1958"|"10"|"$485,000"|"$276,000 WORK PROPOSED"|"1"|"S"|"1958"|"10"|"$10,000"|"NO WORK PROPOSED"|"1"|"U"|"1958"|"5"|"$50,000"|"$50,000 WORK PROPOSED"|"1"|"U"|"1958"|"5"|"$25,000"|"$25,000 WORK PROPOSED"|"0"|||||||"0"||"1"|"S"|"2005"|"20"|"$10,000"|"NO WORK PROPOSED"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"20"|"$280,000"|"$343,000 WORK PROPOSED"|"1"|"CONCRETE,ASPHALT"|"S"|"1997"|"10"|"$200,000"|"$214,000 WORK PROPOSED"|"1"|"U"|"1996"|"5"|"$12,000"|"$12,000 WORK PROPOSED"|"1"|"S"|"2005"|"20"|"$210,000"|"N"|"NO WORK PROPOSED"|"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1958"|"20"|"$560,000"|"$41,000 WORK PROPOSED"|"1"|"S"|"1997"|"20"|"$48,000"|"NO WORK PROPOSED"|"1"|"S"|"1997"|"20"|"$210,000"|"$145,000 WORK PROPOSED"|"1"|"S"|"1997"|"20"|"$259,000"|"$145,000 WORK PROPOSED"|"1"|"S"|"1997"|"5"|"$29,000"|"$10,000 WORK PROPOSED"|"1"|"S"|"S"|"1997"|"5"|"$205,000"|"$25,000 WORK PROPOSED"|"1"|"S"|"1958"|"15"|"$199,000"|"$8,000 WORK PROPOSED"|"1"|"S"|"1997"|"5"|"$92,000"|"NO WORK PROPOSED"|"1"|"1"|"S"|"1997"|"15"|"$259,000"|"$57,000 WORK PROPOSED"|"1"|"S"|"1997"|"5"|"$393,000"|"$34,000 WORK PROPOSED"|"1"|"1"|"S"|"1997"|"5"|"$90,000"|"$90,000 WORK PROPOSED"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"5"|"$20,000"|"NO WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1997"|"7"|"$165,000"|"$40,000 WORK PROPOSED"|"1"|"COMMON"|"S"|"1997"|"20"|"$200,000"|"NO WORK PROPOSED"|"1"|"INSTRUCT"|"S"|"1997"|"20"|"$80,000"|"NO WORK PROPOSED"|"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1958"|"15"|"$517,000"|"$40,000 WORK PROPOSED"|"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1958"|"15"|"$366,000"|"$75,000 WORK PROPOSED"|"1"|"MASONRY"|"S"|"1958"|"15"|"$19,000"|"NO WORK PROPOSED"|"0"|||||"0"||"S"|"U"|"0"|"1"|"1986"|"5"|"$172,000"|"$25,000 WORK PROPOSED"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"10"|"$237,000"|"$18,000 WORK PROPOSED"|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"HALF OF ROOF AT END OF USEFUL LIFE"|"S"|"2005"|"20"|"$199,000"|"$250,000 WORK PROPOSED"|"1"|"PLASTIC"|"S"|"2005"|"20"|"$199,000"|"$250,000 WORK PROPOSED"|"1"|"COPPER"|"S"|"1997"|"10"|"$156,000"|"$21,000 WORK PROPOSED"|"1"|"IRON"|"S"|"1997"|"15"|"$181,000"|"$21,000 WORK PROPOSED"|"1"|"NAT_GAS"|"S"|"1997"|"0"|"$19,000"|"$10,000 WORK PROPOSED - NEW HOT WATER BOOSTER HEATER AT DISH MACHINE INSTALLED 2008"|"1"|"S"|"1997"|"5"|"$135,000"|"$128,000 WORK PROPOSED"|"1"|"DD_MZ"|"1"|"BOILERSTEA"||"S"|"1997"|"5"|"$242,000"|"NO WORK PROPOSED"|"1"|"S"|"1997"|"15"|"$32,000"|"NO WORK PROPOSED"|"1"|"S"|"2007"|"25"|"$450,000"|"NO WORK PROPOSED"|"1"|"S"|"1997"|"10"|"$388,000"|"$60,000 WORK PROPOSED"|"1"|"S"|"1997"|"20"|"$312,000"|"$25,000 WORK PROPOSED"|"1"|"S"|"1997"|"10"|"$30,000"|"$10,000 WORK PROPOSED"|"1"|"S"|"2007"|"25"|"$190,000"|"$10,000 WORK PROPOSED"|"1"|"S"|"1997"|"15"|"$237,000"|"NO WORK PROPOSED"|"1"|"S"|"1997"|"15"|"$157,000"|"$20,000 WORK PROPOSED"|"1"|"S"|"1997"|"1997"|"$17,000"|"$30,000 WORK PROPOSED"|"1"|"S"|"1997"|"10"|"$129,000"|"$10,000 WORK PROPOSED"|"0"||||"0"|"$123,000 WORK PROPOSED"|"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"2,200,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||"FULL"||"1"||"FAIR"|"INADEQUATE STORAGE SPACE"|"$3,690,000"|"S"|"1"|"Robertson Strong Apgar Architects"|"1054 James Street, Syracuse, NY 13203"|"3154727761"|"joliver@rsa-architect.com"|"James S. Oliver"|"013795"|"I ACCEPT"|12/16/2010 11:18:06 AM| 289|"Alden CSD"|"14010106"|"Alden Maintenance Building"|"3005"|"01/07/2010"|"13190 Park Street"|"Alden, New York"|" 14004"|"ANNUAL"|"12/01/2010"|"1976"|"7500"|"1"|"0"|"0"|"DISTRICT"|"OTHER"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1976"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1976"|"10"|"0"|"Interceptor not serviced recently"|"1"|"S"|"1976"|"10"|"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"10"|"0"|"Minor cracking and spalling in locatins that are visible"|"1"|"S"|"1972"|"120"|"0"||"0"||||"0"||"1"|"S"|"1972"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1972"|"10"|"0"|"Dents and scratches"|"1"|"S"|"1972"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"2002"|"7"|"0"|"No wire guard wraps around lens over kitchen lighting fixtures"|"1"|"1"|"S"|"1976"|"10"|"0"|"Telephone and data was extended from adjacent high school"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1972"|"7"|"0"||"1"|"COMMON"|"S"|"1972"|"15"|"0"|"Minor patching and repair may be required"|"1"|"COMMON"|"S"|"1972"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1972"|"10"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"10"|"0"|"Areas of damaged metal panel cladding and minor rust spots"|"0"|||||"0"||"0"|||||"0"||"U"|"U"|"0"|"0"|"2000"|"3"|"12,875.00"|"Doors are old, rusted, bent, and are not closing and opening easily. Hardware is inadequate and functioning poorly."|"0"|"S"|"1972"|"5"|"0"|"Minor patching required at drive ramp"|"0"|||||"0"||"0"|"ALUMINUM"|"U"|"NA"|"1998"|"3"|"6,570.00"|"Single pane glazing. Two windows are broken"|"OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"10"|"0"|"Metal roof over purlins"|"0"|||||"0"||"1"|"COPPER"|"S"|"1976"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"CV,OTHER"|"0"|||"NF"|||"0"||"0"||||"0"||"1"|"U"|"1976"|"3"|"350"|"Carrier Window AC unit in office and break room area"|"1"|"U"|"1976"|"3"|"17,000"|"Cross Ventilation fans"|"0"||||"0"||"1"|"U"|"1976"|"3"|"0"|"Cost covered in #78"|"1"|"U"|"1976"|"3"|"0"|"Cost covered in #78"|"1"|"S"|"1992"|"7"|"0"|"Fire alarm system is an extension of the high school"|"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"U"|"1976"|"3"|"2625"|"Exit signs are incadescent. Recommend upgrading to LED"|"0"||||"0"||"1"|"0"|"0"|"Building is used as a maintenance garage. Accessibility is not required"|"GOOD"|"Building is used as a maintenance garage and is kept up as such. Building is orderly and organized."|"FAIR"|"Building is well kept based on the use"|"0"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"|"Additional fixtures is the shop area would bring up lighting levels to acceptable levels"|"1"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"|||"1"|"1"|"1"|"FAIR"||"62,096.00"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/16/2010 11:20:18 AM| 291|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG #8 PAULINE BUSH CENTER "|"0008"|"05/06/2010"|"459 PHILO ROAD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1967"|"8964"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"|"Adult Education"|"42"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"42"|"0"|"0"|||"8"|"4980"|"ADMIN,COMPROOM,TECHSHOP,OTHER"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"5"|"0"||"1"|"S"|"1972"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1996"|"5"|"20,000"|"Replace transformers."|"0"||||"0"||"1"|"S"|"1967"|"5"|"0"||"1"|"S"|"1967"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"30,000"|"Slurry sealed in 2007."|"1"|"ASPHALT"|"S"|"2000"|"5"|"10,000"|"Slurry sealed in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"5"|"14,000"|"Upgrade Reception area/Custodial storage and Classroom partition. "|"1"|"S"|"1994"|"5"|"70,000"|"Acoustical lay-in ceiling. "|"0"||||"0"||"1"|"S"|"S"|"1968"|"5"|"15,000"|"REkeying and ADA hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"5"|"75,000"|"Fluorescent T-12, non-electric ballast."|"1"|"1"|"S"|"1968"|"1"|"20,000"|"Replace PA system."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"150,000"||"1"|"INSTRUCT,COMMON"|"S"|"1994"|"5"|"140,000"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"5"|"0"||"1"|"METAL"|"S"|"1994"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2006"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2006"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"200,000"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"5"|"0"||"1"|"NAT_GAS,ELECTRIC"|"S"|"1995"|"2"|"3,000"|"Not ASME, replace with tank-less water heater."|"1"|"S"|"1993"|"5"|"0"|"ADA compliant"|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"1999"|"2"|"50,000"|"Replace fan coil. "|"1"|"S"|"1999"|"10"|"75,000"|"Replace rooftop units."|"1"|"S"|"1968"|"5"|"0"|"Gas piping."|"1"|"S"|"1999"|"5"|"0"||"1"|"S"|"1999"|"5"|"45,000"|"Johnson Control upgrades needed."|"1"|"E"|"2001"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1988"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"64,200"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/16/2010 11:43:24 AM| 297|"Schodack CSD"|"49150104"|"Bus Garage"|"5005"|"10/06/2010"|"1477 S. Schodack Road"|"Castleton-on-Hudson"|" 12033"|"ANNUAL"|"01/01/2011"|"1967"|"16,250"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Storage/Maintenance"|"0"|||"0"|"0"||||||"0"|"0"|"OTHER"|"Bus Facility"|"1"|"1"|"12000"|"0"|"0"|"S"|"2006"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"10"|"0"||"1"|"SITESEPT"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"2008"|"15"|"0"|"Added emergency generator"|"1"|"E"|"2008"|"15"|"0"|"Hard piped to open drainage (see 32)"|"1"|"E"|"2008"|"20"|"0"|"Added additional rip/rap"|"1"|"E"|"2008"|"20"|"0"||"0"||||"0"|"see 32"|"0"|||||||"0"|"see 32"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"20"|"0"||"1"|"CONCRETE"|"U"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"15"|"0"|"Replaced column foundations 2008"|"1"|"S"|"2000"|"10"|"10"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"E"|"2008"|"15"|"0"|"Replaced bus lift"|"1"|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"1"|"S"|"2010"|"15"|"0"|"Connected phone to district system 2010"|"0"||||"0"||"1"|"COMMON"|"E"|"2008"|"20"|"0"|"New concrete floor in bus bay in 2008"|"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2008"|"15"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"7"|"0"|"Corrected column foundations"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"7"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2008"|"10"|"0"|"Replaced failing windows 2008"|"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2000"|"10"|"0"|"Foam insulation roof continually maintained"|"0"|||||"0"||"1"|"COPPER"|"S"|"2000"|"10"|"0"||"1"|"IRON"|"S"|"2008"|"10"|"0"||"1"|"OIL"|"U"|"1970"|"5"|"8500"||"1"|"S"|"1967"|"10"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1970"|"3"|"5000"|"Should consider replacing furnace"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"2000"|"3"|"105,000"|"recommend replacing 1970 air handling unit"|"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1980"|"0"|"30,000"|"Replace systems panel and add smoke/heat strobes"|"1"|"U"|"1980"|"0"|"0"|"Hardware and connect to building"|"1"|"E"|"2008"|"2008"|"0"|"Suppression at fueling station replaced"|"1"|"S"|"2000"|"7"|"0"||"1"|"E"|"2008"|"15"|"0"|"Installed emergency generator 2008"|"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"0"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"GOOD"|"2008/2009 Capital Project"|"233,500"|"U"|"0"|"Stieglitz Snyder Architecture"|"425 Franklin Street, Buffalo, NY 14202"|"716-828-9166"|"psnyder@stieglitzsnyder.com"|"Philip Snyder"|"21279"|"I ACCEPT"|12/16/2010 1:54:30 PM| 298|"Putnam Valley CSD"|"48050304"|"High School"|"0010"|"08/24/2010"|"146 PEEKSKILL HOLLOW RD "|"PUTNAM VALLEY "|" 10579"|"ANNUAL"|"08/01/2011"|"2000"|"150000"|"3"|"5"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"628"|"9,10,11,12"|"0"|"0"|"0"|"628"|"0"|"0"|||"33"|"47665"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"48"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"48"|"0"||"1"|"S"|"2000"|"38"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"28"|"0"||"1"|"S"|"2000"|"48"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2001"|"15"|"0"||"0"|"S"|||"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"7"|"0"||"1"|"CONCRETE"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"E"|"2000"|"10"|"0"|"Y"|"astro turf - football; grass x 2 - baseball"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"1"|"E"|"2000"|"16"|"0"||"1"|"E"|"2000"|"11"|"25000"|"Finishes over 5 years"|"1"|"E"|"2000"|"8"|"0"|"Routine maintenance"|"1"|"S"|"2000"|"8"|"0"||"1"|"S"|"E"|"2000"|"10"|"0"||"1"|"E"|"2000"|"15"|"0"||"1"|"E"|"2000"|"20"|"0"||"1"|"1"|"S"|"2000"|"18"|"0"||"1"|"S"|"2000"|"8"|"0"||"1"|"1"|"S"|"2000"|"13"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"2000"|"20"|"0"||"1"|"COMMON"|"E"|"2000"|"25"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"16"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"2000"|"20"|"0"||"E"|"S"|"0"|"1"|"2000"|"11"|"0"||"1"|"E"|"2000"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2000"|"20"|"0"||"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"0"||"1"|"PLASTIC"|"S"|"2000"|"10"|"3000"|"For skylight fall protection"|"1"|"COPPER"|"S"|"2000"|"38"|"0"||"1"|"IRON"|"S"|"2000"|"38"|"0"||"1"|"NAT_GAS,OTHER"|"S"|"2000"|"8"|"0"||"1"|"S"|"2000"|"38"|"0"||"0"||"1"|"OTHER"|"heat pumps"|"E"|"2000"|"10"|"0"||"1"|"S"|"2000"|"28"|"0"|"Geothermal bore hole field"|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"18"|"0"||"1"|"S"|"2000"|"28"|"0"||"1"|"S"|"2000"|"28"|"0"||"1"|"S"|"2000"|"8"|"75000"|"Loss of signal anomaly in certain areas reported since system commissioning."|"1"|"S"|"2000"|"8"|"18000"|"Horn/strobes required in classrooms to meet SED requirements"|"1"|"S"|"2000"|"8"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"3"|"16000"|"Provide emergency lighting in laboratories; provide area of rescue signage"|"1"|"S"|"2000"|"18"|"0"|"tested quarterly"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"0"|"0"||||"0"|"1"|"KITCHEN,HVAC,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"0"|"1"|"GOOD"||"137000"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"cblack@kgdarchitects.com"|"Calvin L. Black, PE"|"078642"|"I ACCEPT"|12/16/2010 2:20:00 PM| 299|"Alden CSD"|"14010106"|"Alden Primary at Townline"|"0008"|"01/07/2010"|"Broadway"|"Alden, New York"|" 14004"|"ANNUAL"|"12/01/2010"|"1961"|"63,420"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"387"|"Pre-K,K,2"|"0"|"0"|"0"|"387"|"0"|"0"|||"25"|"19,150"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1961"|"10"|"0"||"1"|"SITESEPT"|"S"|"1997"|"10"|"0"||"1"|"S"|"1961"|"7"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"S"|"1961"|"15"|"0"||"1"|"S"|"1961"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1997"|"5"|"0"|"Spotty patched areas around dumpster in driveway and bus loop"|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"10"|"0"|"Sections of concrete curb are damaged"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"|"N"|"Fence is rusting, baselines are not defined, and grass is mounded up along center field and baselines."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"15"|"0"|"Some cracking and chipping of parge coat"|"0"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"|"Minor cracks in drywall at corridor door heads and exterior window heads"|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"7"|"0"|"Wood shelving laminate in cracking and delaminating"|"1"|"S"|"S"|"2001"|"10"|"0"|"Room #118-front of bathroom door has a small crack and delamination. Room #127 has chipping on entry door"|"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"2003"|"3"|"252,888"|"Outdated GE panelboards original to the building have exceeded their useful life"|"1"|"S"|"2001"|"10"|"0"|"No occupancy sensors"|"1"|"1"|"S"|"2002"|"7"|"0"|"Data rack has no additional cooling"|"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"|"Unusual spacing between VCT tiles"|"1"|"COMMON"|"S"|"2008"|"15"|"0"|"Mechanical and electrical rooms - painted finish is worn on concrete"|"1"|"INSTRUCT,COMMON"|"S"|"1964"|"15"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2001"|"20"|"0"|"Uneven and cracking at expansion joint and floor slab. Crack in floor slab transition between terrazzo and asbestos"|"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"1"|"1"|"0"||"S"|"2001"|"7"|"0"|"Cracking of brick at unit ventilator and moisture penetration at corners. 1950 courtyard porcelain panels are rusting through allowing water infiltration"|"1"|"MASONRY"|"S"|"1961"|"15"|"0"||"1"|"MASONRY"|"S"|"2001"|"15"|"0"||"S"|"S"|"1"|"1"|"2001"|"10"|"0"|"Non-insulated glass"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"2001"|"10"|"0"|"Water staining on faces. 1950 courtyard porcelain panels are rusted throuh allowing water infiltration."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"S"|"2003"|"10"|"0"|"Standing water found in a few locations. Tectum panels along windows in cafeteria are discolored andn one is sagging"|"1"|"PLASTIC"|"S"|"2003"|"10"|"0"||"1"|"COPPER"|"S"|"1999"|"10"|"0"|"Some piping not insulated and not identified"|"1"|"IRON,GALVANIZED,PVC"|"S"|"1961"|"3"|"0"|"Floor drains missing cover"|"1"|"NAT_GAS"|"S"|"2009"|"7"|"0"||"1"|"S"|"2001"|"10"|"0"|"No floor drains in toilet room in classrooms"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1997"|"10"|"0"|"One boiler has some exterior burn marks"|"0"||||"0"||"1"|"S"|"2001"|"15"|"0"|"Nurse's area has window AC units"|"1"|"S"|"2003"|"15"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"20"|"0"|"1964 classrooms have no passive relief air path"|"1"|"S"|"1996"|"5"|"0"|"1961 and 1964 aer not on building management systems. 1996 and 2001 are on BMS air compressor and are reaching end of useful life."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2001"|"7"|"0"|"Gym/cafeteria and courtyard have exiting incandescent or non-illuminated exit signs that may not operate in an emergency"|"1"|"S"|"2003"|"10"|"0"||"1"|"1"|"0"|"There are accessible interior and exterior routes"|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"1"||"Water damaged ceiling tiles"|"0"|"0"|"0"|"0"|"1"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"GOOD"|"Nurses suite is not ventilated. Open duct to outside in boiler room."|"0"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"1"|"LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"288,917.00"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/16/2010 2:27:18 PM| 301|"Norwich City SD"|"08120005"|"Bus Garage"|"5010"|"02/22/2010"|"3 BUS GARAGE LANE "|"NORWICH "|" 13815"|"ANNUAL"|"12/01/2010"|"1968"|"22,000"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus Garage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"WELL"|"S"|"2002"|"10"|"60,000"|"Additional well and filtration system."|"1"|"SITESEPT"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"35"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1968"|"8"|"20,000"|"Replace overhead service entrance with new underground service entrance conductors. Includes sawcutting, trenching and pavement patching and a spar 4 inch underground conduit."|"1"|"S"|"2010"|"30"|"25,000"|"Improve drainage, provide new storm piping at downspouts to prevent puddling and ice build up."|"0"||||"0"||"1"|"S"|"2010"|"30"|"20,000"|"Addition of inlets to help with surface drainage."|"0"||||"0"||"1"|"SURFACEH2O"||"1"|"E"|"2010"|"40"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"15"|"130,000"|"Existing asphalt repair and replace with heavy-duty asphalt. Provide topographic survey showing existing topo and utility info. Create concrete aprons at doors. Install ADA parking. Add parking signage."|"1"|"ASPHALT"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"72"|"0"||"1"|"S"|"2002"|"17"|"0"||"1"|"S"|"2002"|"32"|"0"||"1"|"S"|"S"|"2002"|"27"|"0"||"1"|"S"|"1968"|"38"|"0"||"1"|"S"|"2002"|"5"|"220,000"|"Below grade vehicle lifts in 2002 maintenance bay are too close to overhead doors to meet DOT inspection requirements. Lift in rear of building is not vertically installed. Replace/relocate."|"1"|"1"|"S"|"2002"|"8"|"123,000"|"Replace 400 amp fusible main disconnect, original ITE and Square D panelboards. Provide new general power panelboard. Provide a 125kW diesel standby generator with a subbases fuel tank."|"1"|"S"|"2002"|"12"|"20,400"|"Replace high-bay metal halide luminaires with energy saving high-bay fluorescent. Provide digital timeclock and occupancy sensor lighting controls in service bays."|"1"|"1"|"S"|"2002"|"3"|"113,500"|"Provide computer network cabling system, computer network hardware. Replace existing telephone system. Provide telecomm grounding system. Provide UPS units. Provide proximity card readers. Provide security intrusion detection and surveillance."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"12"|"0"||"1"|"COMMON"|"S"|"2002"|"52"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"50"|"20,000"|"Floor trench drain/grate at Vehicle Storage A111 too narrow for cleaning. Replace with wider unit."|"MASONRY,STEEL"|"0"|"1"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"50"|"10,000"|"Structural steel columns - appropriate surface prep and painting is recommended to extend the life of the steel."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"21"|"4,000"|"HM door and frame in original 1968 building is rusted and in need of replacement. Replace with new FRP door without glass. Provide panic hardware."|"1"|"S"|"1968"|"6"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"2002"|"10"|"6,400"|"Windows in original 1968 portion of building are single pane, non-thermal and in need of replacement."|"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"1"||"S"|"2008"|"15"|"5,000"|"Correct roof leak in vehicle storage bay. Correct non-functioning gutters and downspouts at 2002 portion of building, tie into storm drainage system."|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"30"|"32,600"|"Add water softening system. Minimal bus wash system to replace inoperable system. Test water quality to meet NYS Health Dept. standards. Repair existing RPZ valve in mechanical room."|"1"|"IRON,COPPER"|"S"|"2002"|"30"|"2,000"|"Replace the existing oil water separator manhole covers."|"1"|"NAT_GAS"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"30"|"24,000"|"Replace compressed air system with a larger compressor. Add combined emergency eye wash and shower unit. Replace mixing type hose faucets with vacuum breaker spout and check stops."|"0"||"1"|"BOILERWATE"||"E"|"2001"|"16"|"0"||"1"|"E"|"2001"|"11"|"0"||"0"||||"0"||"1"|"S"|"2001"|"20"|"65,000"|"Provide ventilation and heating unit to serve Office A101. Provide new sensors to improve current exhaust fans. Modify existing outside air louver and/or roof drainage to eliminate the build up of ice."|"1"|"S"|"2001"|"40"|"65,000"|"There are many elbow and joints failing and replacement of piping system may be required before the end of useful life is expected."|"1"|"E"|"2001"|"31"|"0"||"0"||||"155,000"|"There is not a DDC system at the Bus Garage. Add boiler, pumps, AHUs, exhaust fans, etc to current District wide DDC system to allow monitoring and control of facility."|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"0"||||"0"||"1"|"S"|"2006"|"11"|"0"||"0"||||"0"||"1"|"1"|"7,000"|"Exterior man door at 1968 portion of building has step. Provide flush condition from threshold to pavement."|"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Evidence of rust stains throughout facility"|"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,388,270"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Barbara Chambers"|"024424"|"I ACCEPT"|12/16/2010 2:58:49 PM| 302|"Putnam Valley CSD"|"48050304"|"Middle School"|"0004"|"08/27/2010"|"PEEKSKILL HOLLOW RD "|"PUTNAM VALLEY "|" 10579"|"ANNUAL"|"08/01/2011"|"1972"|"60270"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"623"|"5,6,7,8"|"0"|"0"|"1"|"623"|"0"|"0"|||"18"|"13700"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"48"|"0"|"sprinkler - original 1972"|"1"|"MUN_UTILIT"|"S"|"1998"|"22"|"0"||"1"|"S"|"1998"|"8"|"0"|"Propane for domestic hot water"|"1"|"UTIL"|"BELOW"|"S"|"1998"|"28"|"0"||"1"|"S"|"1972"|"22"|"0"||"0"||||"0"||"1"|"S"|"1972"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"1998"|"6"|"0"||"1"|"CONCRETE"|"S"|"1998"|"6"|"20000"|"P1-minor repair=5K; P3-install new sidewalk=15K"|"0"||||"0"||"1"|"S"|"2000"|"10"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1972"|"13"|"0"||"1"|"S"|"1972"|"13"|"65000"|"Corridor walls should be raised to structure above"|"1"|"S"|"1972"|"13"|"55000"|"Wall refinishing allowance"|"1"|"S"|"2005"|"5"|"10000"|"Replacement of select ceiling tiles"|"1"|"U"|"1972"|"0"|"130000"|"Full locker replacement"|"1"|"S"|"S"|"1990"|"6"|"25000"|"Miscellaneous hardware and door replacement"|"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"10"|"0"|"Missing fireman's recall function"|"1"|"1"|"S"|"1972"|"5"|"110000"|"Update all panelboards due to age; receptacles needed in classrooms"|"1"|"S"|"1998"|"8"|"25000"|"Lighting okay but has outlived its life expectancy. Lighting needed in parking area"|"1"|"1"|"S"|"1998"|"8"|"150000"|"Replace entire PA/Intercom system and clock system"|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"15"|"0"||"1"|"COMMON"|"S"|"1972"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1972"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2005"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"13"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"13"|"0"||"1"|"MASONRY"|"S"|"1972"|"13"|"0"||"1"|"MASONRY"|"S"|"1972"|"8"|"0"||"S"|"S"|"0"|"1"|"1972"|"5"|"0"||"1"|"S"|"1972"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"Y"|"1990"|"5"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"6"|"0"||"0"|"PLASTIC"|"S"|"1995"|"6"|"0"||"1"|"COPPER"|"S"|"1972"|"12"|"0"||"1"|"IRON"|"S"|"1972"|"12"|"0"||"1"|"OTHER"|"S"|"1998"|"6"|"0"||"1"|"S"|"1972"|"5"|"116000"|"6K-replace faucets with metering type; 110K-replace all old plumbing fixtures"|"0"||"1"|"OTHER"|"heat pumps"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"28"|"10000"|"Geothermal bore hole field. Replace corroded manifold and insulate."|"1"|"S"|"1998"|"10"|"0"|"Air conditioning in all spaces except gym"|"1"|"S"|"1998"|"0"|"120000"|"Gym unit beyond useful life; recommend replacement"|"1"|"S"|"1998"|"28"|"20000"|"Recommend water treatment program. Occasional pipe leaks at equipment reportedly due to water quality."|"1"|"S"|"1998"|"28"|"0"||"1"|"S"|"1998"|"8"|"0"|"DDC Invensis Network 8000"|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"1972"|"1972"|"0"||"1"|"S"|"1999"|"9"|"12000"|"Additional emergency lighting required in gymnasium"|"1"|"S"|"2009"|"39"|"0"||"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"1"|"GOOD"|"Gym system has accumulated dirt, etc in ductwork"|"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"0"|"1"|"FAIR"||"868000"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"cblack@kgdarchitects.com"|"Calvin L. Black, PE"|"078642"|"I ACCEPT"|12/16/2010 3:06:59 PM| 303|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BUILDING 9 "|"1017"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1989"|"4700"|"2"|"10"|"0"|"DISTRICT"|"DIST_ADMIN"||"12"|"9,10,11,12"|"0"|"0"|"0"|"12"|"0"|"0"|||"2"|"1600"|"ADMIN,OTHER"|"New Visions"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"5"|"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"5"|"10,000"|"Replace transformer."|"0"||||"0"||"1"|"S"|"1989"|"5"|"0"||"1"|"S"|"1989"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"15"|"0"|"Slurry sealed in 2007."|"1"|"ASPHALT"|"S"|"2000"|"3"|"0"|"Slurry sealed in 2007"|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"1"|"20,000"|"Replace after HVAC upgrades, GWB and acoustical lay-in ceiling."|"0"||||"0"||"1"|"S"|"S"|"1989"|"5"|"6,000"|"Rekeying and add hardware. "|"1"|"S"|"1989"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1989"|"5"|"0"||"1"|"S"|"1989"|"5"|"10,000"|"Fluorescent T-12 with non-electric ballast."|"1"|"1"|"S"|"1989"|"2"|"5,000"|"New PA system is needed. "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"120,000"|"0"|"Replaced 4,700 SF."|"0"|||||"0"||"1"|"COMMON"|"S"|"1989"|"5"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1989"|"10"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1989"|"10"|"0"||"1"|"METAL"|"S"|"1989"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1989"|"4"|"2,500"|"Metal"|"1"|"S"|"1989"|"10"|"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"Y"|"1989"|"5"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"15"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1989"|"20"|"0"||"1"|"ELECTRIC"|"S"|"1989"|"2"|"3,000"|"Not ASME, replace with tank-less water heater."|"1"|"S"|"1989"|"10"|"4,000"|"Replaced all lavatory trim to meet SED metering faucets (4)."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1989"|"4"|"60,000"|"HVAC system needs to be updated."|"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"4"|"10,000"|"Needs updating."|"1"|"S"|"1989"|"4"|"10,000"|"Needs updating."|"1"|"S"|"1989"|"5"|"0"||"1"|"S"|"1989"|"5"|"0"||"1"|"S"|"1989"|"4"|"20,000"|"System not controlled, system needs to be upgraded."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1989"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"GOOD"||"189,200"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/16/2010 3:41:58 PM| 304|"Putnam Valley CSD"|"48050304"|"Elementary School"|"0001"|"08/20/2010"|"OSCAWANA LAKE ROAD "|"PUTNAM VALLEY "|" 10579"|"ANNUAL"|"08/01/2011"|"1935"|"67307"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"700"|"K,1,2,3,4"|"0"|"0"|"1"|"700"|"0"|"0"|||"30"|"23568"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10000"|"E"|"2005"|"20"|"0"||"1"|"WELL"|"S"|"2005"|"20"|"0"||"1"|"SITESEPT"|"S"|"1962"|"12"|"110000"|"Study current issues; allowance of 10K for corrective work on 1962 field"|"1"|"S"|"2005"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2005"|"35"|"0"||"1"|"S"|"2005"|"30"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"OTHER"|"runs off site"|"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"E"|"2005"|"10"|"0"||"1"|"CONCRETE"|"E"|"2005"|"8"|"2500"|"Recommend repair/replacement of select areas"|"1"|"S"|"2005"|"15"|"0"||"0"||||"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"10"|"0"||"1"|"S"|"1962"|"11"|"0"||"1"|"S"|"1962"|"11"|"97500"|"Recommend new finishes in all areas not addressed in 2005 project"|"1"|"S"|"2005"|"15"|"0"|"At classrooms with exposed tectum, new drop ceilings will be needed in the coming years"|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"S"|"2005"|"15"|"0"|"At 1962 & 1950 wing, doors that were not replaced in 2005 will need to be replaced "|"1"|"S"|"1962"|"15"|"0"||"1"|"S"|"2008"|"30"|"0"|"Elevator installed in 2008"|"1"|"1"|"S"|"2005"|"35"|"30000"|"Updated panelboards required in 1955 and 1935 wings due to old age"|"1"|"S"|"2005"|"15"|"91500"|"Updated lighting required in Auditorium and classrooms in 1955 wing; new lighting controls needed for Gym"|"1"|"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2005"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"15"|"0"||"1"|"COMMON"|"S"|"1962"|"15"|"0"|"Recommend repair of terrazzo in one wing"|"1"|"INSTRUCT"|"S"|"2000"|"25"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"15"|"0"|"Masonry repair and repointing"|"1"|"MASONRY"|"S"|"1962"|"6"|"0"|"District is replacing flue; brick will need to be replaced and repointed"|"1"|"MASONRY"|"S"|"2005"|"20"|"0"||"U"|"U"|"0"|"0"|"1962"|"0"|"40000"|"Minimum done in 2005. Replacement of six (6) sets of original hollow metal exterior doors needed"|"1"|"S"|"2005"|"10"|"0"|"Recommend renovation of exit stair at end of 1962 corridor "|"0"|||||"0"||"1"|"ALUMINUM,STEEL,WOODCLAD"|"S"|"Y"|"2005"|"5"|"88200"|"1962 wing windows are beyond useful life (leak and let in cold air) and must be replaced. 1950's wing windows are nearing end of useful life."|"METONMET,WOODONWOOD,OTHER"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"20"|"0"|"Recommend the monitoring of existing support system issues which were corrected in 2005."|"0"|||||"0"||"1"|"GALVANIZED,COPPER,OTHER"|"S"|"1935"|"5"|"120000"|"Piping is well beyond useful life. No reports of leaks."|"1"|"IRON,COPPER"|"S"|"2005"|"45"|"0"||"1"|"OIL"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"15"|"46000"|"40K-some faculty toilet areas in 1935 & 1962 wings need upgrading; 6K-provide metering faucets on existing lavatories."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"20"|"260000"|"One HV unit in 1955 wing and 6 HV unitsin gym, cafeteria and two classrooms are beyond useful life"|"1"|"S"|"2005"|"55"|"0"||"1"|"S"|"2005"|"20"|"40000"|"Some units in 1955 & 1962 wings in need of replacement"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"16500"|"Horn/strobes needed in classrooms to meet SED requirements"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1962"|"1962"|"0"||"1"|"S"|"2005"|"15"|"18000"|"Additional lighting needed in Auditorium; exterior emergency egress lighting required"|"1"|"S"|"2005"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"1"|"GOOD"|"Accumulated dirt, etc in ductwork of 1962 addition"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"GOOD"||"957700"|"S"|"1"|"KGD Architects, PC"|"285 Main Street, Mount Kisco, NY 10549"|"914-666-5900"|"cblack@kgdarchitects.com"|"Calvin L. Black, PE"|"078642"|"I ACCEPT"|12/16/2010 4:02:41 PM| 305|"Commack USFD"|"58041003"|"Burr Road Maintenance Shed"|"2010"|"02/16/2010"|"202 Burr Road"|"Commack, NY"|"11725"|"ANNUAL"|"05/01/2011"|"1972"|"912"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"District Materials Storage"|"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"OTHER"|"Storage of District Materials"|"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1972"|"9"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1998"|"19"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"24"|"0"||"1"|"ASPHALT"|"S"|"2000"|"24"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"19"|"0"||"1"|"S"|"1972"|"19"|"0"||"0"||||"0"||"1"|"S"|"1972"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1972"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"16"|"0"||"1"|"S"|"1995"|"14"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1972"|"19"|"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"14"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"4"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1972"|"9"|"0"||"1"|"S"|"1972"|"4"|"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"1972"|"4"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1980"|"9"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"FAIR"||"$ 0"|"S"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/16/2010 4:18:51 PM| 307|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"LABOR RELATIONS CENTER #10 "|"1019"|"05/06/2010"|"459 PHILO ROAD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1990"|"4700"|"2"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"12"|"9,10,11,12"|"0"|"0"|"0"|"12"|"0"|"0"|||"2"|"1600"|"ADMIN,OTHER"|"New Visions"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1991"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1991"|"5"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1991"|"5"|"10,000"|"Replace transformers."|"0"||||"0"||"1"|"S"|"1989"|"5"|"0"||"1"|"S"|"1989"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"3"|"5,000"|"Slurry sealed in 2007. "|"1"|"ASPHALT"|"S"|"2000"|"3"|"5,000"|"Slurry sealed in 2007. "|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"1"|"20,000"|"Replace after HVAC upgrades, GWB and acoustical lay-in ceiling. "|"0"||||"0"||"1"|"S"|"S"|"1990"|"5"|"6,800"|"Rekeying and ADA hardware. "|"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"5"|"5,000"||"1"|"S"|"1990"|"5"|"10,000"|"Fluorescent T-12, non-electric ballast."|"1"|"1"|"S"|"1990"|"2"|"5,000"|"New PA system is needed."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"1"|"50,000"|"Replace 4,700 SF."|"0"|||||"0"||"1"|"COMMON"|"S"|"1989"|"5"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"10"|"0"||"1"|"METAL"|"S"|"1990"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"5"|"2,500"|"Metal"|"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"WOODCLAD"|"S"|"Y"|"1990"|"5"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"15"|"32,400"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"20"|"0"||"0"|"ELECTRIC"|"S"|"1990"|"2"|"3,000"|"Not ASME, replace with tank-less water heater."|"1"|"S"|"1990"|"10"|"4,000"|"Replaced all lavatory trim to meet SED metering faucets (4). "|"1"|"VAV"|"0"|"BOILERWATE"||"S"|"1990"|"4"|"60,000"|"HVAC system needs to be upgraded."|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"4"|"10,000"|"Needs to be updated."|"1"|"S"|"1990"|"4"|"10,000"|"Needs to be updated."|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"1"|"40,000"||"1"|"S"|"1990"|"1"|"20,000"|"System not controlled, system needs to be updated."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1990"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"GOOD"||"89,200"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/17/2010 8:54:51 AM| 308|"Lake George CSD"|"63070104"|"Jr.-Sr. High School"|"0004"|"06/29/2010"|"381 Canada Street"|"Lake George"|" 12845"|"ANNUAL"|"01/01/2011"|"1926"|"126,000"|"3"|"5"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"||"493"|"7,8,9,10,11,12"|"0"|"1"|"1"|"493"|"0"|"0"|||"55"|"40,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1989"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"1"|"CONCRETE"|"S"|"1989"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"1970"|"5"|"493,000"|"N"|"Bleachers to be replaced; tennis courts to be reconstructed."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1989"|"15"|"0"||"1"|"S"|"1989"|"15"|"0"||"1"|"S"|"1989"|"15"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"S"|"1989"|"5"|"405,000"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1989"|"5"|"60,000"|"Replace antiquated lighting fixtures."|"1"|"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"5"|"28,000"|"Carpet in select rooms to be replaced."|"1"|"INSTRUCT,COMMON"|"S"|"1989"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"10"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1989"|"10"|"0"||"1"|"MASONRY"|"S"|"1989"|"10"|"0"||"1"|"MASONRY"|"S"|"1989"|"10"|"0"||"S"|"S"|"0"|"1"|"2002"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1989"|"10"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"15"|"0"||"1"|"GLASS"|"E"|"2010"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1989"|"5"|"69,000"|"Install backflow preventer and replace galvanized piping."|"1"|"IRON"|"S"|"1989"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1989"|"5"|"15,000"|"Summer hot water heater needed."|"1"|"S"|"1989"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1989"|"5"|"26,000"|"Replace burners."|"0"||||"0"||"1"|"S"|"2002"|"15"|"180,000"||"1"|"S"|"2002"|"5"|"280,000"|"Replace unit ventilators, upgrade relief system, provide added ventilation."|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1995"|"5"|"175,000"|"Upgrade pneumatic temperature control system to DDC."|"1"|"S"|"2002"|"5"|"30,000"|"Additional fire alarm devices needed."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"2004"|"0"||"1"|"S"|"1989"|"5"|"25,000"|"Additional exit and emergency lights needed."|"0"||||"0"||"1"|"1"|"25,000"|"Access to stage is needed"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||"FULL"||"1"||"GOOD"||"1,811,000"|"S"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, NY 12061"|"518-479-4000"|"mweber@mosaicaa.com"|"Martin Weber"|"12772"|"I ACCEPT"|12/17/2010 10:22:09 AM| 309|"Caledonia-Mumford CSD"|"24020104"|"Middle/High School"|"0001"|"05/24/2010"|"99 North St"|"Caledonia "|" 14423"|"ANNUAL"|"8/1/11"|"1964"|"158,530"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"554"|"6,7,8,9,10,11,12"|"0"|"1"|"0"|"554"|"0"|"0"|||"27"|"22,800"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2006"|"15"|"0"||"0"|"SITESEPT"|"S"|"1998"|"10"|"0"||"1"|"E"|"2000"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"1998"|"10"|"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2006"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"2"|"0"|"Cracks and minor potholes need to be properly cleaned and sealed or filled. Estimated cost - $37,500."|"1"|"CONCRETE"|"S"|"2000"|"5"|"0"|"Some cracked or heaving sidewalk flags need to be replaced. Estimated cost - $4,500."|"0"||||"0"||"1"|"E"|"2006"|"20"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"5"|"0"|"Structural cracks were observed in storage room 201 and should be repaired and adjacent expanion joints resealed. Estimated cost - $5,000."|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"S"|"1998"|"5"|"0"||"1"|"S"|"1998"|"5"|"0"|"Stair risers should be painted in stairwells 1,2,6,7. Estimated cost - $1,500."|"1"|"S"|"1998"|"15"|"0"||"1"|"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"1"|"E"|"2008"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"1"|"0"|"Auditorium, Library, Music Room and IT Office carpet should be replaced. Estimated cost - $98,000."|"1"|"INSTRUCT"|"S"|"1998"|"10"|"0"||"1"|"COMMON"|"S"|"1998"|"5"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"20"|"0"|"Wood floor are located in gyms and auditorium stage."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"10"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1998"|"10"|"0"||"0"|"MASONRY"|"S"|"1964"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"|"Minor patchings required at exteior loading dock and stair to basement. Estimated cost -$1,150."|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1998"|"2"|"0"|"Replace deteriorated spandrel panels, single pane windows and repair failed window seals. Estimated cost - $29,050."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2001"|"10"|"0"|"Rain water leaks into the building from the flashing and/or masonry weep holes at Corridor 04 asjacent to the Maintenance Room. Some standing water observed. Estimated cost - $3,500."|"1"|"PLASTIC"|"S"|"2001"|"10"|"0"||"1"|"COPPER"|"S"|"1998"|"15"|"0"||"1"|"IRON"|"S"|"1998"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"|"Faucets and Flushometers are excellent. Porcelain fixtures shoulg be replace and several toilet rooms upgraded for ADA accessibility. Estimated cost - $200,000."|"0"||"1"|"BOILERWATE"||"E"|"2008"|"20"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"|"Split A/C in computer lab 207, office practice and keyboarding room 139, and secretarial practice room 141 should be replaced. They appear to be undersized for their purpose. Estimated cost - $25,000."|"1"|"S"|"1998"|"10"|"0"|"The 1964 air handlers, unit ventilators should be scheduled for replacement. Estimated cost - $691,000."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"|"Some additional emergency backup units in boy's and girl's bathrooms, including mechanical room 231 should be installed , and an LED exit light above exterior door in room 123. Estimated cost - $2,000."|"1"|"S"|"1983"|"2"|"0"|"We recommend a new standby power generator, transfer switch and associated panels to boilers, PA etc. in case of power outages. Estimated cost - $92,000"|"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM"|"FULL"|"0"|"0"|"1"|"GOOD"||"$3,184,417"|"S"|"1"|"Hunt Engineers, Architects, Land Surveyors, P.C."|"4 Commercial Dr. Suite 300, Rochester, NY 14614"|"585-327-7950"|"cakej@hunt-eas.com"|"John Cake, AIA"|"013885"|"I ACCEPT"|12/17/2010 10:48:54 AM| 312|"Norwich City SD"|"08120005"|"Perry Browne"|"0004"|"03/04/2010"|"BEEBE AVE "|"NORWICH "|" 13815"|"ANNUAL"|"12/01/2010"|"1955"|"75,853"|"1"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"458"|"3,4,5"|"0"|"1"|"1"|"458"|"0"|"0"|||"30"|"24,020"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"10"|"$20,000"|"New sewer main connection to Municipal System"|"1"|"S"|"1955"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"42"|"0"||"1"|"S"|"1955"|"5"|"$19,000"|"Rod & clean storm drain piping, replace manholes. Provide storm inlet to remove low puddling area. Fill area @ NE corner bus loop by vistor parking to drain adjacent catch basin/prevent puddling this area."|"0"||||"0"||"1"|"S"|"1955"|"5"|"$20,000"|"Replace damage inlets throughout parking areas (approx. 10)"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"$175,000"|"Modify layout for more efficient parent drop-off system. Various main entrance improvements. Provide sliding or combination of fencing/planting to reduce impact of exterior freezing."|"1"|"CONCRETE"|"S"|"2002"|"20"|"$70,000"|"Remove/replace existing asphalt, walk to N & NW. Remove/replace deteriorated, cracked & spalled concrete @ following locations: Front of school @ bus loop & walk connecting bus loop to N asphalt play area."|"1"|"E"|"2008"|"18"|"0"||"1"|"S"|"1955"|"10"|"$107,000"|"N"|"Football/Soccer Fields: Provide deep aeration, topdressing, overseeding & fertilization. Fill low spots & improve drainage as needed. Remove existing deteriorated softball backstop & provide new. Chainlink fencing @ fields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1987"|"50"|"0"||"1"|"S"|"2002"|"52"|"$10,000"|"Modify mailboxes/fireshutter at main office to acheive rating."|"0"|"S"|"1955"|"25"|"$233,000"|"Remove insulation backed pegboard, consider acoustic treatment. Add display cases & enclosed tack boards. Replacement of some casework, glazing, rusted toilet room accessories, kitchen equipment."|"1"|"S"|"2007"|"20"|"$8,500"|"Replace ceiling @ student toilet rooms (grid is reusable @ some locations/rusted @ others). Replace ceiling at rooms 3078, 3082."|"1"|"E"|"2008"|"38"|"0"||"1"|"S"|"S"|"2007"|"31"|"$233,500"|"Wireglass replaced or filmed over in areas that have potential for impact & injury. Consider replacement of door closers. Replace smoke doors and several interior doros. Provide permanent ADA signage. Replace door hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1955"|"2"|"$630,500"|"Replace original panel, add surge suppression devices to main swbd/computer panel. Add ltg. panel in ea area of bldg. Provide diesel standby generator. Replace all cloth wire. Provide add. convenience receptacles."|"1"|"S"|"2008"|"18"|"$54,000"|"Replace incandescent lgt. various areas. Add occupancy sensors in occupied spaces. Replace high-bay luminaries utilizing metal-halide lamps w/ energy savnig high-bay fluorescent luminaires in the Gymnasium."|"1"|"1"|"S"|"2008"|"23"|"$598,500"|"Add/Provide/Improve/Remove: ADA assistive listening, Computer Network Cabling Sys., Telecomm. Cable, Video Dist., Servers, Network Hardware, Telephoen Sys. & Grounding, Security, Surveillance, Provide split system HVAC"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"$29,000"|"Replace asbestos containing flooring at Aud. stairs & landing. Replace floor mounted casework islands incld. ADA sinks in Classrooms 3012, 3014, 3016 & 3018"|"1"|"COMMON"|"S"|"2002"|"12"|"$10,000"|"Ceramic tile in Lobby 3052 Vestibule 3019A are missing grout and tile due to salt corrosion. Replacement is needed."|"1"|"COMMON"|"U"|"1991"|"1"|"$12,000"|"Refinish the stage floor."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1987"|"50"|"0"||"MASONRY,STEEL"|"0"|"1"||"1"|"0"|"1"|"1"|"1"||"S"|"1987"|"30"|"$31,500"|"Paint lintels, clean brick efflorescense, Reconstruct brick in 2 small areas. Repoint brick. Add brick expansion joints."|"1"|"MASONRY"|"S"|"2007"|"72"|"$5,000"|"Remove and replace lead cap, clean masonry."|"0"|||||"0"||"S"|"S"|"1"|"1"|"2010"|"31"|"$20,000"|"Replace at boiler 3036, cooler 3042, Electric 3019 (with louver) and Vestibule 3019A (includes large sidelight)."|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"Y"|"2010"|"35"|"$40,000"|"Windows in orig. bldg. replace summer 2010. Sliding (rescue) windows in 1987 add. difficult to open, dont meet size requirements. Replace window units & treatment. Uncluded needed abatement."|"WOODONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"12"|"0"||"1"|"PLASTIC"|"S"|"2002"|"12"|"0"||"1"|"COPPER"|"S"|"2006"|"25"|"$85,000"|"Replace original water service to bldg installed 1955. Run from street main into bldg. Patch asphalt. Povide backflow prevention on water service into bldg to protect the public water supply."|"1"|"IRON,COPPER"|"S"|"1955"|"5"|"$10,800"|"Testing of Drainage Piping. Removal of fixtures (drinking fountains/spittoons)"|"1"|"OTHER"|"S"|"2006"|"30"|"$15,000"|"The summer oil fired water heater appears to be original and has performed it's useful life and should be replaced with a more efficient natural gas unit."|"1"|"S"|"2008"|"15"|"$20,000"|"Kitchen wrist blade handles/pre-rinse spray faucet. Clsrm toilet rm upgrade. Mop sink improvements. Misc fixture replacements and upgrades."|"1"|"CV"|"1"|"BOILERWATE"||"E"|"2008"|"22"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"S"|"2001"|"11"|"0"||"1"|"S"|"2001"|"21"|"$960,000"|"Provide heating & ventilation air to 1987 addition currently served by fintube radiation only. Upgrade control to clrsm supply fans. Replace auditorium, Gym, & Cafeteria AHU w/ rooftop units."|"1"|"S"|"2008"|"48"|"0"|"2008 capital project replaced the entire piping system and reconnected to the existing equipment."|"1"|"S"|"2001"|"41"|"0"|"The original 1955 ductwork is still in place and was cleaned int he 2008 capital project. No issues with teh ductwork were reported at that time."|"1"|"S"|"2008"|"22"|"0"|"There is DDC control to various equipment throughout the bldg. The original AHU still have penumatic controls, reheat coils serving each space have DDC control with new sensors (2008)."|"1"|"S"|"2010"|"20"|"$20,000"|"Provide fire alarm notificatino appliance in all spaces occupied by 2 or more people."|"1"|"S"|"1990"|"0"|"$103,000"|"Replace conventional fire alarm initiation devices with addressable devices. Includes wiring replacement with new FPLP cabling to improve system reliability."|"0"||||"0"|"There are no sprinlkers above the stage area. Provide sprinkler system to protect the stage area. (limited system off domestic service)"|"1"|"S"|"2008"|"12"|"$10,200"|"Replace incandescent exit signs on Stage w/ exit signs utilizing LED technology & integral batteries. Provide emergency lgt in Gang Toilet rooms, kitchen, locker room, Gym & Practice."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"FAIR"|"Classrooms have little acoustic treatment (hard ceilings, floors and walls w/ some peg board). Consider acoustic ceiling sytem from noise absorption & above ceiling utility accesibility."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Mold in shower area."|"1"|"OTHER"|"Stale air quality (not mold odor) noticed in student Toilet Rooms. Possibility of mold behind pegboard in classrooms."|"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"SPOT"|"1"|"0"||||"0"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"$4,520,100"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca NY 14850"|"607-277-7100"|"info@tetratech.com"|"Barbara Chambers"|"024424"|"I ACCEPT"|12/17/2010 12:58:09 PM| 314|"North Bellmore UFSD"|"28020402"|"Jacob Gunther Elementary School"|"0001"|"07/29/2010"|"2600 Regent Place"|"North Bellmore"|" 11710"|"ANNUAL"|"04/01/2010"|"1956"|"44,947"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"239"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"239"|"0"|"0"|||"15"|"11250"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"10"|"19,000"|"Replace existing fuel oil tank monitoring & overall alarm system."|"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2003"|"15"|"0"||"1"|"S"|"1957"|"10"|"0"|"School to perform routinemaintenance & ensure storm drainaage system is free of all blockages."|"0"||||"0"||"1"|"S"|"1957"|"10"|"0"|"District shall perform annual cleanouts of all existing catch basins & ensure proper function."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1957"|"3"|"585,000"|"Recommend complete replacement of asphalt pavement & curbing along bus loop & parking lot area."|"1"|"CONCRETE,ASPHALT"|"S"|"1957"|"5"|"44,000"|"Majority of walkways cracked & present tripping hazard-recommend replacement of cracked walks w/new."|"1"|"S"|"2005"|"15"|"0"|"existing playgrunds in good condition."|"1"|"S"|"1957"|"5"|"0"|"Y"|"Routine maintenance required by District."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"1"|"S"|"1957"|"20"|"0"|"School to monitor all various non-structural cracks."|"1"|"S"|"1957"|"20"|"0"||"1"|"S"|"2010"|"15"|"465,486"|"Majority of ceilings are concealed spline type. Should District require, ceilings can be replaced."|"0"||||"0"||"1"|"S"|"S"|"1957"|"3"|"0"|"Interior door & hardware to be replaced summer 2011."|"1"|"S"|"1957"|"20"|"0"|"Original risers in good condition."|"0"|"S"|||"0"|"Currently no access to 2nd floor for wheelchair bond person. Elevator installation could result in lost of classroom space."|"1"|"0"|"S"|"2000"|"5"|"60,000"|"Provide additional sub-panels & outlets to meet District Technology needs."|"1"|"E"|"2010"|"15"|"0"||"1"|"1"|"S"|"1957"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"83,000"|"Priority 1-VAT replace summer 2010."|"1"|"INSTRUCT"|"S"|"1957"|"10"|"0"|"Painted concrete floors in good shape-recommend maintenance by Owner."|"1"|"INSTRUCT"|"S"|"1957"|"10"|"0"|"All existing wood floors in good shape."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1957"|"25"|"17,000"|"Overall conditionof masonry good. Few masonry cracks in need of repointing."|"1"|"MASONRY"|"S"|"2010"|"25"|"0"|"Chimney was repointed & repaired during summer 2010."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"10"|"0"||"1"|"S"|"1957"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"|"All windows have been replaced as part of last Bond Issue & are in good condition."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"18"|"0"||"0"|||||"0"||"0"|"COPPER"|"S"|"1957"|"15"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1957"|"15"|"0"||"1"|"OIL"|"S"|"1996"|"5"|"0"|"Existing hot water heater is adequate. Maintain service & annual inspections."|"1"|"S"|"1957"|"5"|"337,000"|"Furnish & install handicapped accesible work spaces & sinks. Convert (2) toilets to ADA."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2010"|"35"|"0"||"0"|"S"|"2010"|"35"|"0"||"1"|"S"|"2007"|"8"|"0"|"Window A/C units"|"1"|"S"|"2009"|"15"|"0"|"Overall condition of existing unit ventilators are in good condition."|"1"|"S"|"2010"|"10"|"0"|"All steam traps have been refurbished."|"1"|"S"|"1957"|"15"|"0"||"1"|"S"|"1957"|"5"|"86,000"|"Pneumatic conrols on all equpment are in need of rehabilitation. Recommend all existing UV's be refurbished & new DDC central control panel installed."|"1"|"E"|"2003"|"14"|"0"||"1"|"E"|"2003"|"14"|"0"||"1"|"S"|"2000"|"2000"|"0"|"Existing fire suppression system is adequate in existing Kitchen. Owner to maintain existing system with annual inspections & maintenances."|"1"|"E"|"2010"|"15"|"0"||"0"||||"0"||"1"|"1"||"Elevator required"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"|"Majority of existing lights are to be replaced as part of ESCO project."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"School is to perform routine maintenance on ventilation equipment & filters."|"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"|"0"|"1"||"FAIR"||"1,821,486.00"|"S"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/17/2010 2:36:43 PM| 315|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"INSTRUCTIONAL SUPPORT CENTER BLDG 11"|"0020"|"05/06/2010"|"459 PHILO ROAD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1964"|"14670"|"1"|"10"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER"||"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ADMIN,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1990"|"5"|"0"||"1"|"S"|"1964"|"5"|"0"||"0"||||"0"||"1"|"S"|"1964"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Slurry sealed in 2007."|"1"|"CONCRETE"|"S"|"2005"|"5"|"0"|"Slurry sealed in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"3"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"3"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"10"|"12,800"|"Wood doors/rekeying/ADA hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"1"|"S"|"1990"|"1"|"10,000"|"New PA system is needed."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"5"|"0"||"1"|"COMMON"|"S"|"1990"|"5"|"0"||"1"|"COMMON"|"S"|"1996"|"2"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"10"|"0"||"1"|"METAL"|"S"|"1990"|"10"|"0"||"0"|"OTHER"|"S"|"1987"|"3"|"0"||"S"|"S"|"0"|"1"|"1990"|"5"|"60,000"|"Exterior door."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1990"|"2"|"140,000"|"Windows need replacement."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"15"|"0"||"0"|||||"0"||"1"|"IRON"|"S"|"1990"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1999"|"5"|"3,000"|"Not ASME, provide new tank-less gas water heater."|"1"|"S"|"1990"|"10"|"0"|"ADA compliant."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"2009"|"15"|"0"|"Rooftop units/replace HVAC 2009."|"0"|"S"|"2009"|"5"|"0"||"1"|"S"|"2009"|"10"|"0"|"Part of rooftop units."|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"1990"|"5"|"0"|"Gas piping."|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1998"|"1998"|"0"|"Inspected four times a year."|"1"|"S"|"1999"|"5"|"2,000"|"Upgrades needed."|"0"|"S"|||||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"106,200"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/17/2010 2:40:37 PM| 317|"Hauppauge UFSD"|"58050603"|"High School"|"0008"|"9/28/10"|"500 Lincoln Blvd."|"Hauppauge "|" 11788"|"ANNUAL"|"5/1/11"|"1968"|"386,420"|"3"|"16"|"1"|"DISTRICT"|"INSTRUCT"||"1240"|"9,10,11,12"|"0"|"1"|"1"|"1240"|"0"|"0"|||"51"|"46,180"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"2"|"550"|"1"|"20,000"|"S"|"1994"|"20"|"78,000"|"Replace single wall steel tank at Auto Shop"|"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"SITESEPT"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"20"|"0"|"Modification for boiler replacement 2009"|"1"|"UTIL"|"ABOVE"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"18"|"0"||"0"||||"0"||"1"|"S"|"1968"|"15"|"21,000"|"Provide catch basins at northwest corner of Maintenance area"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"5"|"1,173,000"|"Asphalt replacement south lot, bus loop, rear lot, part of north lot"|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"5"|"85,000"|"Replace deteriorated sidewalks"|"0"||||"0"||"1"|"S"|"2009"|"12"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"25"|"73,000"|"Interior cracks, repointing - boiler room, roof access, weight room, stairwell, music practice room corridor, prep rooms between 346-344 & 339-338 & corridor adj to Rm 195"|"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"2010"|"15"|"165,000"|"Recommend replacement of dropped ceiling & plaster ceiling ceiling in Rooms 380 & 381"|"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"S"|"2010"|"5"|"726,000"|"Replace original doorknobs to lever type hardware, hold opens, panic devices, 'B' label doors, smoke doors, replace wood doors - where needed - reverse doors at dead end corridor"|"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"20"|"0"|"Routine repairs recommended on freight elevator"|"1"|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"10"|"18,000"|"Recommend additional flourescent lighting be installed in stairwells"|"1"|"1"|"S"|"1998"|"10"|"0"||"1"|"E"|"2009"|"25"|"150,000"|"Recommend replacement of pool filters"|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"6"|"152,000"|"Recommend replacement of carpet in several locaitons including Library, Rooms 380,381,146,257A & Counseling Office"|"1"|"INSTRUCT"|"S"|"2010"|"8"|"742,000"|"Long range plan for VAT flooring removal."|"1"|"INSTRUCT"|"S"|"1968"|"25"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"12"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"2010"|"25"|"248,000"|"7 decorative brick piers along auditorium, southeast corner of bldg, outide stairtower, upper gymnasium wall, elevator penthouse, southend of building, masonry around loading dock"|"1"|"MASONRY"|"S"|"1968"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2004"|"20"|"34,000"|"Replacement of ext doors, boiler room, penthouse & basement areas"|"1"|"S"|"1968"|"10"|"85,000"|"Replace damaged slabs & stairs at west side of building"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2004"|"20"|"0"||"CONMETMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"5"|"0"||"1"|"PLASTIC"|"S"|"1994"|"5"|"0"||"1"|"IRON,COPPER"|"S"|"1968"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1968"|"8"|"0"||"1"|"NAT_GAS"|"S"|"2004"|"10"|"0"||"1"|"S"|"2010"|"10"|"0"|"Plumbing fixtures replaced in 10 Science Rooms"|"1"|"CV"|"1"|"BOILERWATE"||"E"|"2009"|"35"|"0"||"1"|"E"|"2009"|"35"|"0"||"1"|"E"|"2010"|"25"|"0"|"New Stand alone chiller installed for auditorium"|"1"|"E"|"2009"|"20"|"285,000"|"All UV's replaced,mechanical ventilation to gym coaches' off, band secretary, practice rms, interior offices off Library, metal & auto shops, "|"1"|"S"|"2004"|"20"|"135,000"|"Insulation on chilled water piping throughout basement"|"1"|"S"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"1968"|"1968"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"1997"|"8"|"0"||"1"|"0"|"905,000"|"ADA sinks in Art, Home & Careers, Ceramic Rms, Multi-stall toilets. Recommend conversion of additional toilets to handicapped accessible"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"1"|"FIREALARM,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"4,170,000"|"E"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson, NY"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/17/2010 2:54:49 PM| 320|"Port Jefferson UFSD"|"58020602"|"Edna Louise Spear Elementary School"|"0002"|"10/05/2010"|"SCRAGGY HILL ROAD "|"PORT JEFFERSON "|" 11777"|"ANNUAL"|"05/01/2011"|"1957"|"107980"|"1"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"591"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"0"|"591"|"0"|"0"|"OTHER"|"Stage"|"28"|"22400"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC"||"1"|"0"|"0"|"3"|"9000"|"S"|"1986"|"8"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"8"|"0"||"1"|"S"|"2006"|"12"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1957"|"8"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"70000"|"Additional catch basins should be installed as part of pavement project. Recommend collection of rainwater into underground storm water drywells."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2003"|"3"|"836211"|"On site sstorm drainage structures should be installed. Recommend removing Adminitration portable bldg. and relocating the Kindergarten play structures to free apace for potential bus or car drop off/pick up area."|"0"|"CONCRETE,ASPHALT"|"U"|"2004"|"3"|"579750"|"Asphalt and concrete sidewalks in need of repair especially in small courtyard and around 500 wings. Tremendous amount of sidewalks may be replaced on priority basis."|"1"|"U"|"2004"|"3"|"195480"|"Create ADA access to K and Pre-K playground area."|"1"|"S"|"2003"|"8"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"1"|"S"|"1957"|"25"|"0"||"1"|"S"|"1957"|"25"|"24900"|"Monitor walls with non-structural cracks. Cut expansion joints into glazed block walls to alleviate further movement. Interior Glazing doesn't meet NYSBC. Gypsum Board: corridor walls above ceiling are in need of fire stopping."|"1"|"S"|"1997"|"7"|"1089200"|"Several locations concealed spline ceilings need replacement. Heating supply & return lines insulation contains asbestos. Recommend removal of pipe wrap if/when ceilings are replaced."|"1"|"E"|"2010"|"20"|"0"|"Lockers in pool locker room should be considered for replacement."|"1"|"S"|"S"|"1996"|"8"|"4800"|"Recommend a replacement program to replace doors on a priority basis."|"1"|"S"|"1957"|"20"|"0"|"Steps to Boiler Room."|"0"||||"0"||"1"|"1"|"S"|"1997"|"17"|"0"||"1"|"S"|"1995"|"6"|"0"|"NYSERDA program to replace lighting scheduled for Summer 2011."|"1"|"0"|"U"|"1990"|"2"|"289000"|"Replace existing phone/communication system with a Bogen Quantum Multicom IP System utilizing the existing network as a backbone for the system."|"1"|"S"|"2009"|"15"|"0"||"1"|"COMMON"|"U"|"1998"|"3"|"97600"||"1"|"INSTRUCT"|"S"|"1996"|"6"|"256300"|"VAT floors in closets and some rooms need to be addressed immediately. Some 12x12 floor tile contain asbestos and should be eventually removed."|"1"|"COMMON"|"S"|"1957"|"25"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"12"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1957"|"25"|"87600"|"Control joints shpul be raked out and repointed. All joints must be treated with waterproofing. Addrss upper SE corner at exterior wall of stage first. "|"1"|"MASONRY"|"S"|"1957"|"20"|"10000"|"Replace (2) concrete chimney caps."|"0"|||||"0"||"E"|"E"|"0"|"1"|"1997"|"12"|"0"||"1"|"S"|"1957"|"3"|"0"|"address ADA ramp/drop curb as part of sidewalk/curb work."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"12"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"5"|"0"|"recoomend a building thermal scan be performed on all the roof levelsto determine if any of the existing rigid insulation is wet."|"1"|"GLASS"|"S"|"1996"|"5"|"0"||"1"|"GALVANIZED"|"S"|"1957"|"10"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1957"|"10"|"0"||"1"|"OIL"|"S"|"1975"|"2"|"87000"|"Domestic HW to 200/300/400 wings. Install new dom HWH in Main Bldg. Install new HW supply & circulation piping in sink units and between boiler room & end of loop."|"1"|"S"|"2003"|"12"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"E"|"2006"|"35"|"0"||"1"|"E"|"2002"|"35"|"0"||"1"|"S"|"1975"|"8"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2006"|"20"|"64000"|"Install new domestic HW circulation piping. Install new HW supply & Circulation piping to ea classroom sink. "|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1957"|"6"|"425000"|"Recommend thorough rehabilitation of every UV's control system. Install DDC control panel in ea boiler room.(5) roof top AC units thermostats should be upgraded to networkable t-stats connected to new front end."|"1"|"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"S"|"2004"|"2004"|"0"||"1"|"S"|"2004"|"12"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"4304841"|"U"|"1"|"John A. Grillo Architect PC"|"1213 Main Street, Port Jefferson "|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/17/2010 3:15:36 PM| 322|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BUILDING 12 "|"8022"|"05/06/2010"|"459 PHILO RD "|"ELMIRA "|" 14903"|"ANNUAL"|"08/01/2011"|"1994"|"27920"|"1"|"10"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"249"|"Pre-K,7,8,9,10,11,12"|"0"|"0"|"0"|"249"|"0"|"0"|||"20"|"16582"|"ADMIN,TECHSHOP,OTHER"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"5"|"0"||"1"|"S"|"1994"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1994"|"5"|"0"||"0"||||"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Slurry sealed in 2007."|"1"|"CONCRETE"|"S"|"2000"|"5"|"0"|"Slurry sealed in 2007."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"5"|"0"||"1"|"S"|"S"|"1994"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1994"|"1"|"1,500"|"800 amp, 480V with dry transformer/additional power."|"1"|"S"|"1994"|"5"|"40,000"|"Fluorescent T-12, non-electric ballast."|"1"|"1"|"S"|"1994"|"1"|"10,000"|"Provide new PA system. "|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1994"|"1"|"8,000"|"Replace VCT in toilet rooms."|"1"|"COMMON"|"S"|"1994"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1994"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"10"|"0"||"1"|"METAL"|"S"|"1994"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1994"|"10"|"0"|"Metal."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"2"|"150,000"|"Aluminum windows are past useful life. Seals and operators are in direpair. "|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"1"|"0"|"1"||"S"|"1994"|"1"|"450,000"|"Replace roof in 2011."|"1"|"GLASS"|"S"|"1994"|"1"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"2"|"9,000/3,000"|"Replaced all lavatory trim with metering faucets (10) and insulate all lavatories (6) and replace drinking fountains (2)."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"5"|"28,000"|"Need cooling in Mechanical Room/replace unit and coil in AHU. "|"1"|"S"|"1994"|"5"|"10,000"|"Additional exhaust needed in Cosmetology."|"0"||||"0"||"1"|"S"|"1994"|"2"|"25,000"|"Replace cooling tower. "|"1"|"S"|"1994"|"5"|"0"||"1"|"E"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"S"|"1994"|"5"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"Upgrade to T-8 fixtures to conserve energy."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"704,000"|"S"|"1"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/17/2010 3:48:32 PM| 323|"Hauppauge UFSD"|"58050603"|"Middle School"|"0002"|"7/20/10"|"600 Town Line Road"|"Hauppauge"|" 11788"|"ANNUAL"|"5/1/10"|"1951"|"178,547"|"2"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"1,055"|"6,7,8"|"0"|"1"|"1"|"1,055"|"0"|"0"|||"60"|"57,752"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"8,000"|"E"|"2010"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2010"|"15"|"0"|"Major portion of water service replaced 2010"|"1"|"SITESEPT"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2010"|"15"|"0"|"Upgraded distribution as part of 2010 Bond work"|"0"|"E"|"2010"|"25"|"0"||"0"||||"0"||"1"|"E"|"2010"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2002"|"3"|"501,000"|"Front bus loop, east side parking lot, Lincoln Ave parking lot, large bus staging area to south of campus"|"1"|"CONCRETE"|"S"|"2010"|"10"|"125,000"|"Asphalt concrete walks at south of bldg, parking lot along west side of site"|"0"||||"0"||"1"|"S"|"2000"|"10"|"450,000"|"N"|"Replace 4-lane cinder track w/ new asphalt track w/ EPDM surfacing, continuous "U" flow drainage system, continuous 10' removable safety netting"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"1"|"S"|"1967"|"20"|"0"||"1"|"S"|"1967"|"20"|"185,000"|"Interior CMU cracks needs plaster repair. "|"1"|"E"|"2010"|"20"|"94,000"|"Recommend replacement of concealed spline ceiling in AP Room"|"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"S"|"2010"|"15"|"315,200"|"Replace doorknobs w/ lever type hardware, hold opens, "B" label doors, replace remaining original interior doors"|"1"|"S"|"1967"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"1"|"E"|"2010"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"E"|"2010"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"15"|"390,000"|"Long range plan to remove remaining VAT flooring. VCT tile in 1st & 2nd floor corridors in need of replacement "|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"20"|"0"||"0"|"INSTRUCT"|"E"|"2008"|"20"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"1"|"1"|"0"|"0"||"S"|"2007"|"15"|"270,000"|"Replace 4 lintels, scrape & paint under north lintels. Replace 12 lintels along east & masonry reponting between window units, boys' toilet, brick repair at locker room, parapet above locker room"|"0"|"MASONRY"|"E"|"2010"|"25"|"0"|"Replaced as part of 2010 Bond"|"1"|"MASONRY"|"S"|"1967"|"15"|"22,000"|"Masonry repair along upper window openings "|"S"|"S"|"0"|"1"|"2002"|"15"|"32,000"|"Replace 2 doors at basement & 3 pairs of doors at Auditorium & Guidance Office door"|"1"|"S"|"2010"|"5"|"24,000"|"Replacement of remaining concrete steps outside Gym are in need of replacement"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2010"|"15"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"5"|"1,672,000"|"Roof was replaced in 1994. Current warranty is 20 years"|"1"|"GLASS"|"E"|"1994"|"5"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2010"|"15"|"0"|"Extensive modifications completed - Kitchen, Locker Room"|"1"|"IRON"|"E"|"2010"|"20"|"0"|"Extensive modifications completed - Kitchen, Locker Room"|"1"|"OIL"|"S"|"1998"|"5"|"28,000"||"1"|"S"|"2010"|"20"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2010"|"35"|"0"||"1"|"E"|"2010"|"35"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"1998"|"15"|"194,000"|"All H & V units refurbished 2009. Recommend replacement of existing electric UV's in "A" Wing & Guidance area"|"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2008"|"15"|"0"|"Complete pneumatic upgrade 2009"|"1"|"E"|"2010"|"15"|"0"||"1"|"E"|"2010"|"15"|"0"||"1"|"E"|"2010"|"2010"|"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"1"|"660,000"|"Handicapped toilet facilities"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"GOOD"|"Major additions & alterations 2010"|"3,290,200"|"E"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson, NY"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/17/2010 3:55:39 PM| 324|"Schodack CSD"|"49150104"|"Maple Hill High School"|"0002"|"06/15/2010"|"1216 Maple Hill Road"|"Castleton-on-Hudson"|" 12033"|"ANNUAL"|"01/01/2011"|"1954"|"89,550"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"358"|"9,10,11,12"|"0"|"1"|"1"|"358"|"0"|"0"|||"26"|"19832"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"0"|||||||"15"|"0"|"(propane) as second fuel"|"1"|"WELL"|"S"|"1998"|"8"|"72,000"|"Provide municipal service in future"|"1"|"SITESEPT"|"S"|"1998"|"8"|"108,000"|"5000 & 2500 tanks to replace"|"1"|"S"|"1998"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"25"|"0"|"New emergency generator 2008"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"1998"|"3"|"250,000"|"Replace 90,000sf asphalt"|"1"|"CONCRETE"|"S"|"1998"|"3"|"195,000"|"Replace and enlarge Bus loop concrete walk"|"0"||||"0"||"1"|"S"|"1998"|"1,525,000"|"3"|"N"|"Reconstruct track, refurbish fields and components"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"5"|"103,000"|"Approaching end of useful life"|"1"|"S"|"2000"|"10"|"0"|"Refurbished lockers in 2000"|"1"|"S"|"S"|"1998"|"4"|"30,000"|"Requires new keying system for 107 doors"|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"1"|"E"|"1998"|"15"|"00"||"1"|"S"|"1998"|"7"|"185,000"|"Change tech room fixtures and add occupancy sensors building wide"|"1"|"1"|"S"|"2010"|"15"|"0"|"Upgraded phone/PA systems 2008"|"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"7"|"0"||"1"|"INSTRUCT"|"S"|"1998"|"7"|"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"15"|"0"|"Replaced asbestos panels 1st and 2nd floor. 2008"|"1"|"MASONRY"|"S"|"1998"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"7"|"16,000"|"Replace all exterior doors"|"1"|"S"|"1998"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"10"|"0"|"Replaced window hardware and balancer"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"||"S"|"1998"|"5"|"0"|"Rubber membrane roof warranty 2009"|"1"|"PLASTIC"|"S"|"1998"|"5"|"0"||"1"|"COPPER"|"S"|"1998"|"20"|"0"||"1"|"IRON"|"S"|"1998"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1998"|"8"|"18,500"|"Summer HWH replace flue piping 2008"|"1"|"S"|"1998"|"15"|"0"||"0"||"1"|"BOILERWATE,BOILERSTEA"||"S"|"2008"|"20"|"40,000"|"Added new steam boiler 2008 - existing 1995 boiler with 5 years expected remaining useful life"|"1"|"S"|"2008"|"15"|"0"|"Replace supply and return piping 2008"|"1"|"S"|"2009"|"10"|"0"|"Replaced window AC units"|"1"|"S"|"2008"|"15"|"0"|"Provided new ventilators in original bldg. 2008"|"1"|"S"|"2008"|"8"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"E"|"2008"|"10"|"0"|"Provided new system controls in original building classrooms"|"1"|"E"|"2008"|"15"|"0"|"Replaced (2) fire alarm sub panels"|"1"|"S"|"1998"|"8"|"0"||"1"|"S"|"1998"|"1998"|"0"|"Kitchen hood has autogas shut-off"|"1"|"S"|"1998"|"7"|"92,000"|"Recommend additional emergency lighting"|"1"|"E"|"2008"|"15"|"0"|"Added emergency generator"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,LIGHTING"|"WARMING"|"1"|"0"|"1"|"GOOD"||"2,624,500"|"S"|"1"|"Stieglitz Snyder Architecture"|"425 Franklin Street"|"716-828-9166"|"psnyder@stieglitzsnyder.com"|"Philip Snyder"|"21279"|"I ACCEPT"|12/17/2010 3:55:56 PM| 326|"North Bellmore UFSD"|"28020402"|"John G. Dinkelmeyer Elementary School"|"0006"|"07/29/2010"|"2100 Waltoffer Avenue"|"North Bellmore"|" 11710"|"ANNUAL"|"04/01/2010"|"1947"|"50,975"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"338"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"338"|"0"|"0"|||"21"|"15750"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"E"|"2007"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1959"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1959"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1959"|"2"|"0"|"To be replaced summer 2011"|"1"|"S"|"1959"|"10"|"0"|"School is to perform routine maintenance & encure storm drainage system is free of all blockages."|"0"||||"0"||"1"|"S"|"1959"|"10"|"0"|"District shall perform annual cleanups of all existing catch basins & ensure proper function."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1947"|"3"|"305,000"|"Majority of asphalt pavement has begun to deteriorate-recommend repaving via milling off upper layer of asphalt throughout"|"1"|"CONCRETE,ASPHALT"|"S"|"1959"|"5"|"30,000"|"Majority of walkways are cracked & present tripping hazard-recommend replacement"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"1959"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1959"|"20"|"0"||"1"|"S"|"1959"|"10"|"0"|"District is to monitor all various non-structural cracks."|"1"|"S"|"1959"|"10"|"0"|"Several interior plaster cracks in building do not appear to be structure in nature-should continue to be monitored."|"1"|"S"|"2010"|"15"|"494,613"|"Majority of ceilings are concealed spline"|"0"||||"0"||"1"|"S"|"S"|"1959"|"3"|"110,000"|"Interior door & hardware replacement scheduled for summer 2011"|"1"|"S"|"1950"|"10"|"0"||"0"||||"0"||"1"|"0"|"S"|"2000"|"5"|"60,000"||"1"|"E"|"2010"|"15"|"0"||"1"|"1"|"S"|"1959"|"5"|"145,000"|"Replace existing PA/Intercom/Clock System throughout building w/new."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"10"|"0"|"Existing carpets in Library & CPU Room in good shape."|"1"|"INSTRUCT"|"S"|"2010"|"15"|"251,000"|"Overall condition of VAT flooring is good to fair-recommend District formulate long-term plan to replace existing VAT on priority basis."|"1"|"INSTRUCT,COMMON"|"S"|"1959"|"10"|"0"|"Painted concrete floors are in good shape-regular mainenance to be done by Owner."|"1"|"INSTRUCT"|"S"|"1948"|"10"|"0"|"All existing wood floors are in good shape."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1959"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2009"|"25"|"54,000"|"Additional exterior masonry reconstruction along east elevation is requested."|"1"|"MASONRY"|"E"|"2009"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"10"|"0"|"Main entrance doors be replaced with new summer 2011."|"1"|"S"|"1959"|"10"|"53,000"|"Existing entrance to building is not handicapped accessible-recommend replacement of all step & surrounding grade."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"|"All windows have been replaced as part of last Bond Issue & are in good shape."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"18"|"0"||"1"|"PLASTIC"|"S"|"2006"|"18"|"0"||"1"|"COPPER"|"S"|"1959"|"15"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1959"|"15"|"0"||"1"|"OIL"|"S"|"1996"|"5"|"0"|"The existing hot water heater is adequate-continue regular service."|"1"|"S"|"1959"|"5"|"303,000"|"Recommend complete renovation of 2nd floor toilet"|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1947"|"2"|"0"|" Boiler replacement schedule for summer 2011"|"1"|"S"|"1947"|"2"|"0"|"Boiler replacement schedule for summer 2011"|"1"|"S"|"2002"|"8"|"0"|"Window A/C units"|"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"1959"|"10"|"0"|"The existing convectors are in good shape"|"1"|"S"|"1959"|"5"|"12,000"||"1"|"S"|"1959"|"5"|"96,000"|"Pneumatic controls on all equipment are in need of rehabilitation-recommend all existing UV's be refurbished & new DDC central control panel be installed."|"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"2000"|"2000"|"0"|"Existing fire suppression system adequate for existing Kitchen-maintain annual inspections & maintenance."|"1"|"E"|"2010"|"15"|"0"||"0"||||"0"||"1"|"0"|"0"|"New Elevator; majority of interior doors do not contain ADA accessible hardware."|"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"|"The majority of existing lights are performed as part of the ESCO project."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"School to perform routine maintenance on all ventilation equipment & filters."|"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"FAIR"||"2,563,613.00"|"S"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/17/2010 3:59:28 PM| 328|"Commack USFD"|"58041003"|"Rolling Hills Primary School"|"0023"|"02/18/2010"|"25 Mc Culloch Drive"|"Dix Hills"|"11746"|"ANNUAL"|"05/01/2011"|"1967"|"46020"|"1"|"3"|"0"|"LSD_NDE"|"INSTRUCT"||"300"|"K,1,2"|"0"|"1"|"0"|"22"|"0"|"0"|||"16"|"14770"|"ADMIN,ART,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,OTHER"|"3 Garages"|"1"|"0"|"0"|"1"|"10000"|"E"|"2009"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"5"|"0"||"1"|"SITESEPT"|"S"|"1967"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"22"|"0"|"New service was istalled."|"1"|"S"|"1967"|"10"|"0"||"0"||||"0"||"1"|"S"|"1967"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1967"|"5"|"0"||"1"|"CONCRETE"|"S"|"2009"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"|"New rubber surfacing was installed."|"1"|"U"|"1967"|"1"|"0"|"N"|"Replace fabric and sleeve posts in 2 baseball fields."|"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1967"|"25"|"0"||"1"|"S"|"1967"|"25"|"0"||"1"|"S"|"1967"|"25"|"0"||"1"|"U"|"1980"|"1"|"300000"|"Replace original ceilings throughout."|"0"||||"0"||"1"|"S"|"S"|"1967"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1967"|"7"|"0"||"1"|"U"|"1967"|"1"|"65000"|"Replace fixtures in classrooms and corridors."|"1"|"1"|"S"|"1967"|"5"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2009"|"1"|"120000"|"Tile was replaced in C.R. # 16 and in Gym. The rest of the classrooms need replacement."|"1"|"COMMON"|"S"|"1967"|"15"|"0"||"1"|"COMMON"|"S"|"2009"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1967"|"15"|"0"||"1"|"MASONRY"|"U"|"1967"|"1"|"10000"|"Repoint brick, repair or replace flashing and some bricks."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"15"|"0"||"1"|"S"|"1967"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"25"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"5"|"0"||"0"|||||"0"||"1"|"COPPER"|"U"|"1967"|"1"|"12000"|"Install isolation valves."|"1"|"IRON"|"S"|"1967"|"5"|"0"||"1"|"OIL"|"S"|"1996"|"5"|"0"||"1"|"S"|"1967"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"25"|"0"||"0"||||"0"||"1"|"U"|"1967"|"1"|"50000"|"Repair or replace roof fans."|"1"|"U"|"1967"|"1"|"70000"|"Replace pumps and unit ventilators in Gym & Cafeteria."|"0"||||"0"||"1"|"U"|"1967"|"1"|"65000"|"Refurbish controls system."|"1"|"U"|"1967"|"1"|"90000"|"Refurbish system to comply with ADA requirements. "|"1"|"U"|"1967"|"1"|"10000"|"Replace smoke detectors as required."|"1"|"S"|"1995"|"1995"|"0"||"1"|"S"|"1967"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"GOOD"||"$ 802,000"|"U"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/17/2010 5:17:10 PM| 329|"Harrison CSD"|"66050106"|"Purchase Modular #1"|"0018"|"09/21/2010"|"Purchase Street"|"Purchase"|" 10577"|"ANNUAL"|"03/01/2011"|"1997"|"3220"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT"||"83"|"K,1,2,3,4,5"|"0"|"0"|"0"|"83"|"0"|"0"|||"4"|"3000"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"11"|"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"11"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"11"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"3000"|"Extend trench drain to capture storm water that washes down ashphalt walkway and across play area, this washes away Fibar playground safety base. "|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"11"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1997"|"11"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"11"|"0"||"0"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"11"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"1"|"S"|"1997"|"11"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"1997"|"11"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"11"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"11"|"3000"|"Modular skirts need repairs. "|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"0"|||||"0"||"1"|"VINYL"|"S"|"Y"|"1997"|"11"|"0"||"WOODONWOOD"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"11"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1997"|"11"|"0"||"1"|"COPPER,PVC"|"S"|"1997"|"11"|"0"||"0"|||||"0"||"1"|"S"|"1997"|"11"|"0"||"0"||"1"|"OTHER"|"Exterior wall pack"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"0"||||"0"||"1"|"S"|"1997"|"11"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"FAIR"||"6000"|"S"|"1"|"TFMG Architecture, PC."|"P.O. Box 63 Bellport NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, R.A."|"021614"|"I accept"|12/18/2010 5:28:42 PM| 330|"Harrison CSD"|"66050106"|"Maintenance Facility - Butler Building"|"2027"|"09/24/2010"|"90 Union Avenue"|"Harrison"|"10528"|"ANNUAL"|"03/01/2011"|"2007"|"4000"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Maintenance Facility"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2007"|"22"|"0"||"1"|"MUN_UTILIT"|"E"|"2007"|"22"|"0"|"Need vent cap on cast iron line along gutter line at rear center of building."|"1"|"E"|"2007"|"22"|"0"|"Paint gas bollards yellow."|"1"|"UTIL"|"BELOW"|"E"|"2007"|"22"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"0"|||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2007"|"22"|"0"||"1"|"ASPHALT"|"E"|"2007"|"22"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2007"|"22"|"0"||"1"|"E"|"2007"|"22"|"0"||"1"|"E"|"2007"|"22"|"0"|"Flammable materials locker not properly installed or vented (Eagle Mfg Co, Model 1947, 45 Gal capacity)."|"1"|"E"|"2007"|"22"|"0"||"1"|"E"|"2007"|"13"|"0"||"1"|"E"|"E"|"2007"|"17"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2007"|"22"|"0"||"1"|"E"|"2007"|"22"|"0"||"1"|"1"|"E"|"2007"|"12"|"0"|"Phone lines only"|"0"||||"0"||"1"|"COMMON"|"S"|"2007"|"12"|"0"||"1"|"COMMON"|"S"|"2007"|"10"|"0"||"1"|"COMMON"|"S"|"2007"|"12"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2007"|"22"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"22"|"0"||"1"|"METAL"|"S"|"2007"|"12"|"0"||"0"|||||"0"||"E"|"E"|"0"|"0"|"2007"|"12"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"E"|"NA"|"2007"|"22"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"22"|"0"|"Clean roof gutters"|"0"|||||"0"||"1"|"COPPER"|"E"|"2007"|"22"|"0"||"1"|"COPPER"|"E"|"2007"|"22"|"0"||"1"|"ELECTRIC"|"E"|"2007"|"9"|"0"||"1"|"E"|"2007"|"22"|"0"|"Locker room lav needs pipe wrap."|"0"||"1"|"OTHER"|"Gas fired radiant and gas fired forced air htrs"|"E"|"2007"|"17"|"0"||"1"|"E"|"2007"|"22"|"0"||"1"|"S"|"2007"|"7"|"0"|"Window A/C unit"|"1"|"S"|"2007"|"22"|"0"||"1"|"E"|"2007"|"22"|"0"||"1"|"E"|"2007"|"17"|"0"||"1"|"E"|"2007"|"12"|"0"||"1"|"E"|"2007"|"17"|"0"||"1"|"E"|"2007"|"17"|"0"||"0"||||"0"||"1"|"E"|"2007"|"7"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"1"|"0"|"GOOD"||"0"|"S"|"1"|"TFMG Architecture, PC"|"P.O. Box 63, Bellport, NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, R.A."|"021614"|"I accept"|12/18/2010 5:30:00 PM| 331|"Harrison CSD"|"66050106"|"Purchase Modular #2"|"0024"|"09/21/2010"|"Purchase Street"|"Purchase"|" 10577"|"ANNUAL"|"03/01/2011"|"2003"|"3000"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT"||"80"|"K,1,2,3,4,5"|"0"|"0"|"0"|"80"|"0"|"0"|||"4"|"3000"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"17"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"17"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"17"|"0"||"1"|"CONCRETE"|"S"|"2003"|"17"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"17"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"0"|"1"|"S"|"2003"|"17"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"17"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"17"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"17"|"3000"|"Modular skirts need repairs."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"0"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"0"|||||"0"||"1"|"VINYL"|"S"|"Y"|"2003"|"17"|"0"||"WOODONWOOD"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"17"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"17"|"0"||"1"|"COPPER,PVC"|"S"|"2003"|"17"|"0"||"0"|||||"0"||"1"|"S"|"2003"|"17"|"0"||"0"||"1"|"OTHER"|"Exterior wall packs"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"1"|"S"|"2003"|"17"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"17"|"0"||"0"|"S"|"2003"|"17"|"0"||"0"||||"0"||"1"|"S"|"2003"|"17"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"FAIR"||"3000"|"S"|"1"|"TFMG Architecture, PC"|"P.O. Box Bellport NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, R.A."|"021614"|"I accept"|12/18/2010 6:19:34 PM| 332|"Long Lake CSD"|"20070104"|"Long Lake Central School"|"0001"|"08/19/2010"|"20 School Lane"|"Long Lake"|" 12847"|"ANNUAL"|"11/1/2012"|"1924"|"52,970"|"3"|"3"|"2"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER"|"collaboration of school and community activities"|"68"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"68"|"0"|"4"|"GYM,LIB,STORAGE"||"20"|"9240"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,PREK,SCIENCELAB,SPECED,TECHSHOP"||"1"|"0"|"0"|"1"|"8000"|"S"|"1988"|"6"|"0"||"1"|"MUN_UTILIT"|"S"|"2010"|"30"|"0"||"1"|"SITESEPT"|"S"|"2000"|"20"|"0"||"1"|"S"|"1988"|"10"|"0"|"LP Gas for Science Rooms and FACS"|"1"|"UTIL"|"ABOVE"|"S"|"2004"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"3"|"120,000"|"Many cracks in parking area pavement."|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"4"|"60,000"|"Areas of cracking and deterioration."|"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"2000"|"3"|"80,000"|"N"|"Tennis Court fencing and surface in poor shape."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"|"1958 and 1970 ceiling tile beyond useful life."|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"S"|"1998"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"1"|"S"|"2004"|"15"|"0"|"Additional distribution required in Fitness Center."|"1"|"S"|"2010"|"5"|"0"|"Mixture of T-12, T-8 and metal halide. Should upgrade to T-8 and T-5."|"1"|"1"|"S"|"2006"|"30"|"0"|"PA through phone system."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"6"|"0"|"Older carpet beyond useful life."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"6"|"0"|"Damaged 9x9 (assumed VAT) flooring."|"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"|"Replace older wood flooring beyond useful life."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"15"|"0"||"MASONRY"|"1"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"2002"|"15"|"40,000"|"Some masonry joints require repointing or caulking."|"1"|"MASONRY"|"S"|"2002"|"2"|"3,000"|"Concrete cap needs to be replaced."|"1"|"MASONRY"|"S"|"2002"|"15"|"0"||"S"|"S"|"0"|"1"|"2004"|"15"|"0"||"1"|"S"|"1957"|"6"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"Y"|"2004"|"3"|"180,000"|"Replace wood windows and infill panels."|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"6"|"0"|"Roof pavers on gym exit stair roof deteriorated."|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"2010"|"2"|"50,000"|"Original copper roof drain lines are failing."|"1"|"OIL"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"5"|"1,500,000"|"Consider converting system from steam to HW."|"0"||||"0"||"1"|"S"|"2002"|"5"|"200,000"|"Pneumatic controls should be converted to Direct digital Control (DDC)."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"0"|"U"|||"12,000"|"No ANSUL system at kitchen hood."|"1"|"U"|"2006"|"25"|"50,000"|"Some required egress areas lack emergency lighting."|"1"|"S"|"2006"|"20"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"FAIR"||"2,243,000"|"U"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, New York 12061"|"518-479-4000"|"nwaer@mosaicaa.com"|"Nicholas K. Waer"|"018542"|"I ACCEPT"|12/20/2010 9:03:21 AM| 333|"BOCES Oneida-Madison-Herkimer"|"41900000"|"OHM BOCES Complex"|"0011"|"10/29/2010"|"4747 Middle Settlement Road"|"New Hartford"|"13413-0070"|"ANNUAL"|"11/01/2011"|"1973"|"237,000"|"1"|"9"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"910"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"910"|"0"|"0"|||"74"|"109,272"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"20"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2005"|"35"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2009"|"50"|"0"||"1"|"E"|"2009"|"50"|"0"||"1"|"E"|"2009"|"50"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"1"|"E"|"2009"|"40"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"20"|"0"||"1"|"COMMON"|"E"|"2009"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"50"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"|"Minor repointing needed."|"1"|"MASONRY,METAL"|"S"|"2009"|"20"|"0"|"Suggest capping. Unused masonry chimney. "|"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"20"|"40,000"|"Replace doors not replaced in 2009."|"1"|"E"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"20"|"0"|"Rescue windows in Alt. Ed. are undersized."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"1"|"PLASTIC"|"E"|"2009"|"20"|"0"||"1"|"COPPER"|"E"|"2009"|"20"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"2009"|"20"|"0"||"1"|"NAT_GAS,ELECTRIC"|"S"|"2009"|"10"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"E"|"2009"|"2009"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|||"1"||"GOOD"||"40,000"|"E"|"1"|"MARCH Associates"|"258 Genesee Street, Suite 300, Utica, NY 13502-4632"|"315-733-3344"|"ccrolius@marchassoc.com"|"Cristopher J. Crolius"|"022954"|"I ACCEPT"|12/20/2010 10:25:22 AM| 334|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #1-AUTOMOTIVE "|"0037"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1968"|"17882"|"2"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"90"|"9,10,11,12"|"0"|"1"|"1"|"90"|"0"|"0"|||"4"|"3200"|"TECHSHOP"||"0"||||||||"0"||"0"|"WELL"|"S"|"2005"|"2"|"300,000"||"1"|"SITESEPT"|"S"|"1968"|"5"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1968"|"10"|"5,000"|"Provide exterior lighting."|"0"||||"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1985"|"2"|"180,000"|"Parking, roadways need to be upgraded."|"1"|"CONCRETE"|"S"|"1968"|"5"|"20,000"|"Sidewalk work includes installation of handicap ramp. "|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"25"|"0"||"0"|"S"|"1968"|"20"|"0"||"1"|"S"|"1996"|"10"|"0"|"Some second floor partitions are not rated. "|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"S"|"1996"|"1"|"10,000"|"Stair doors not rated. Need to be replaced with hold opens. "|"1"|"S"|"1968"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"2"|"2,000"|"Replace outdated panels, provide dust-tight covers for recept. in tech areas. "|"1"|"S"|"1968"|"5"|"47,000"|"Replace existing with T8 fixtures, provide shielding for lamps in tech. areas. "|"1"|"1"|"S"|"2002"|"2"|"10,000"|"Provide new PA system."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1996"|"5"|"0"||"1"|"INSTRUCT"|"S"|"1968"|"5"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2003"|"10"|"0"||"1"|"S"|"1968"|"5"|"20,000"|"Sidewalk work includes installation of handicap ramp (from Item #53)."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"3"|"0"|"Original portion of building has tectum roof deck on metal joists. "|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1971"|"2"|"3,000"|"Not ASME, replace with tank-less gas water heater. "|"1"|"S"|"1971"|"6"|"8,800"|"Replace faucet trim (6) and eyewash units (2). "|"0"||"0"|||"S"|||"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"5"|"15,000"|"Replace toilet room exhaust and vehicle exhaust. "|"0"||||"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2007"|"5"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2010"|"2010"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"FAIR"||"298,800"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/20/2010 10:50:47 AM| 336|"South Orangetown CSD"|"50030106"|"GREENBUSH ACADEMY"|"0011"|"05/26/2010"|"623 Western Highway "|"BLAUVELT"|"10913"|"ANNUAL"|"03/31/2011"|"1905"|"6610"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1905"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1905"|"25"|"0"||"1"|"S"|"1905"|"25"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1905"|"25"|"0"||"1"|"S"|"1905"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"10"|"2785"||"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1905"|"20"|"0"||"1"|"S"|"1905"|"20"|"0"||"1"|"S"|"1905"|"20"|"5040"||"1"|"S"|"2004"|"13"|"0"||"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"1905"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"6"|"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"2004"|"15"|"29004"|"There are several active roof leaks. The shingles are wind damaged and deteriorated."|"1"|"COMMON"|"S"|"2004"|"15"|"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1905"|"20"|"0"||"MASONRY,WOOD"|"0"|"1"||"0"|"0"|"1"|"1"|"1"||"U"|"1988"|"1"|"2536"|"There are several sections of damaged and broken wood planks along the front, side and rear elevation. The east elevation wood siding is rotting and damaged by insects."|"1"|"MASONRY"|"S"|"1905"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"15"|"0"||"1"|"S"|"1905"|"20"|"0"||"0"|||||"0"||"1"|"VINYL,WOOD"|"U"|"Y"|"1996"|"1"|"6349"|"There are two boarded up windows on the east elevation. The other three windows on the east elevation are rotting and have been damaged by insects. These windows require replacement."|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"1"|"0"|"0"||"1"|"1"|"1"|"1"|"1"|"1"|"1"|"0"||"U"|"1988"|"0"|"29004"|"There are several active roof leaks. The shingles are wind damaged and deteriorated."|"0"|||||"0"||"1"|"COPPER"|"S"|"1987"|"25"|"0"||"1"|"OTHER"|"S"|"2004"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"9"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"1990"|"9"|"8050"||"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"2005"|"7"|"1524"|"Replace window air conditioning units."|"0"||||"0"||"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"1"|"S"|"1990"|"9"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"1"|"0"|"There is no public access to the building; single occupancy tenant space with no public interaction."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"|"No general purpose classrooms."|"0"|"1"|"0"|"0"|"0"||"1"|"HALLWAYS,OTHER"||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"FAIR"|"There are no fresh air intakes or air filters at the subject property."|"0"|"0"|"0"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"GOOD"||"96601"|"U"|"1"|"EMG"|"222 Schilling Circle, Suite 275, Hunt Valley, MD 21031"|"800-733-0660"|"klcarneval@emgcorp.com"|"Bill Champion"|"087867"|"I ACCEPT"|12/20/2010 11:30:45 AM| 337|"Shelter Island UFSD"|"58070102"|"Shelter Island School"|"0001"|"08/19/2010"|"33 NORTH FERRY ROAD "|"SHELTER ISLAND "|" 11964"|"ANNUAL"|"05/01/2011"|"1925"|"75,500"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"|"Community athletics and other functions"|"250"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"250"|"0"|"0"|||"30"|"38,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"2005"|"10"|"0"||"1"|"WELL"|"S"|"1992"|"10"|"0"||"1"|"SITESEPT"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"5"|"45,000"|"Underground LPG tank to be replaced with an above-ground type."|"1"|"UTIL"|"BELOW"|"S"|"1992"|"5"|"175,000"|"Electric service is maxed out and must be increased."|"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1992"|"10"|"0"||"1"|"CONCRETE"|"S"|"1992"|"5"|"12,000"|"Heaved concrete pads to be replaced."|"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"1992"|"10"|"315,000"|"N"|"Tennis courts, drainage and playfields to be upgraded."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"15"|"0"||"1"|"S"|"1992"|"15"|"200,000"|"A code violation from 1992 regarding a required fire wall will be corrected."|"1"|"S"|"2000"|"10"|"55,000"|"Reconfigure stair enclosure to avoid corridor blockage."|"1"|"S"|"1992"|"5"|"128,000"|"Replace inaccessible ceilings with accessible ones for roof inspections."|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"S"|"1992"|"5"|"50,000"|"Corridor doors in select rooms to be installed or replaced with fire-rated ones."|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"1"|"S"|"1992"|"5"|"50,000"|"Provide additional spare panels for electrical needs."|"1"|"S"|"2009"|"5"|"65,000"|"Existing fixtures have inefficient lamps."|"1"|"1"|"S"|"1992"|"5"|"125,000"|"Update antiquated system with IP telephone system."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2010"|"5"|"50,000"|"Elementary school carpets to be replaced."|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1972"|"10"|"15,000"|"Gym flooring to be reconstructed and refinished."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"1"|"0"|"discoloration"|"S"|"1992"|"5"|"175,000"|"Brick pointing and concrete and steel lintels replacement is required."|"1"|"MASONRY"|"S"|"2010"|"10"|"0"||"1"|"MASONRY"|"S"|"1925"|"5"|"25,000"|"Reconstruction of bowed parapet wall required."|"S"|"S"|"0"|"1"|"2010"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"5"|"225,000"|"Existing windows are chalking; replace with new in the 1923 building."|"METONMET,WOODONWOOD"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1992"|"5"|"275,000"|"Water tank exhibits pitting and is partially underground."|"1"|"COPPER"|"S"|"1992"|"5"|"45,000"|"Gate valves and dilution traps required."|"1"|"OIL"|"E"|"2010"|"15"|"0"||"1"|"S"|"1992"|"5"|"30,000"|"Update elementary and tech wing bathrooms."|"0"||"1"|"BOILERSTEA,FURNACE"||"S"|"1992"|"5"|"175,000"|"Inadequate furnaces in the gym and locker rooms to be replaced."|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"5"|"50,000"|"Select rooms require air conditioning."|"1"|"S"|"1992"|"5"|"150,000"|"Ventilation and make-up air in tech room; additional ventilation in auditorium."|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"1992"|"5"|"175,000"||"1"|"S"|"2004"|"10"|"7,500"|"Select additional fire alarm upgrades in annunciator panel."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2004"|"5"|"30,000"|"Additional exit lights and emergency battery packs for visibility in corridor."|"1"|"S"|"1950"|"5"|"500,000"|"Existing generator requires repair and should be replaced."|"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"COMMSYS,KITCHEN,FIREALARM,FRIDGE,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"3,092,500"|"S"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, NY 12061"|"518-479-4000"|"mweber@mosaicaa.com"|"Martin Weber"|"12772"|"I ACCEPT"|12/20/2010 11:35:23 AM| 338|"BOCES Oneida-Madison-Herkimer"|"41900000"|"Conservation Learning Center"|"2005"|"10/29/2010"|"4747 Middle Settlement Road"|"New Hartford"|"13413-0070"|"ANNUAL"|"11/01/2011"|"1974"|"4960"|"1"|"9"|"0"|"DISTRICT"|"OTHER"|"Maintenance"|"0"||"0"|"0"|"0"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"40"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2008"|"40"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"1"|"E"|"2008"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2008"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2008"|"30"|"0"||"1"|"COPPER,PVC"|"S"|"2008"|"30"|"0"||"1"|"ELECTRIC"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"CV"|"1"|"FURNACE"||"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"GOOD"||"0"|"E"|"1"|"MARCH Associates"|"258 Genesee Street, Suite 300, Utica, NY 13502-4632"|"315-733-3344"|"ccrolius@marchassoc.com"|"Christopher J. Crolius"|"022954"|"I ACCEPT"|12/20/2010 12:02:02 PM| 339|"Harrison CSD"|"66050106"|"Harrison Avenue Elementary School"|"0004"|"09/24/2010"|"480 Harrison Avenue"|"Harrison"|" 10528"|"ANNUAL"|"03/01/2011"|"1924"|"67,678"|"4"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"462"|"K,1,2,3,4,5"|"0"|"1"|"1"|"462"|"0"|"0"|||"26"|"20,800"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GYM,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,TEACHRSRC,OTHER"|"Maintenance area"|"1"|"1"|"2,000"|"0"|"0"|"S"|"1996"|"6"|"150,000"|"Budget to provide separate 10,000 gallon tank. Existing tank is steel/carbon steel. "|"1"|"MUN_UTILIT"|"S"|"1996"|"0"|"105,000"|"Provide fire hydrants on property. Relocate water lines out of electric room."|"1"|"MUN_UTILIT"|"S"|"1954"|"0"|"25,000"|"Repipe pump discharge from storm drainage to sanitary."|"1"|"S"|"1954"|"0"|"20,000"|"Budget to maintain site gas."|"1"|"UTIL"|"BELOW"|"S"|"1989"|"36"|"89,500"|"Upgrade site lighting at south parking lot and perimeter of building. Site electric repairs. "|"1"|"S"|"1954"|"5"|"110,000"|"Increase site storm water drainage capacity, clean existing, including rear play area. "|"0"||||"0"||"1"|"S"|"1954"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"0"|"235,500"|"Resurface rear parking area. Provide new bus circle off Harrison Avenue. "|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"9"|"15,000"|"Replace walks on southeast side. "|"1"|"S"|"1995"|"15"|"10,000"|"Replace CCA."|"1"|"S"|"1954"|"15"|"515,000"|"N"|"Replace existing cinder track with an all-weather track. Reconstruct two existing tennis courts. "|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1924"|"15"|"0"||"1"|"S"|"1924"|"15"|"26,000"|"Boiler room needs 2HR wall and door fire separation from boiler room/crawlspace, remove combustible storage. Fire stop wall penetrations. Fire stopping needed in several areas. Classroom 40 has improper fire stopping material being used. "|"1"|"S"|"1924"|"15"|"149,250"|"Upgrade original building classroom wardrobes. Replace gym folding partition. Upgrade boys/girls toilet doors. Upgrade wall padding at climbing wall. Repair around steam pipe in corner of gym. Stage proscenium curtain certificate expired August 2010. "|"1"|"S"|"1985"|"15"|"220,000"|"Remove/replace original building classroom ceilings and lighting. "|"1"|"S"|"2006"|"9"|"0"||"1"|"S"|"S"|"1954"|"15"|"223,000"|"Repairs, door closers and upgrades needed. Upgrade Auditorium and gym doors and hardware. Additional corridor door closers. Reverse swing classroom corridor doors in original building. Stair enclosures to separate stair from exit corridor. "|"1"|"S"|"1924"|"15"|"53,500"|"Repair non-conforming guardrail condition. Provide raised railing at auditorium balcony face. Possible reconfiguration of stage access, stage extension and additional stairs. "|"1"|"S"|"1924"|"15"|"25,000"|"ADA access Auditorium chair lift. Existing HC lift at Library. "|"1"|"1"|"S"|"1996"|"36"|"268,000"|"Replace 4 decorative pole lights front of building. Provide electric hand dryers in all gang toilets. Balance existing power distribution, add new panels where required. Replace original Frank Adams panels. Condsider GFCI at sinks in 1954 wing. "|"1"|"S"|"1996"|"11"|"31,000"|"Upgrade 2 wall mounted exterior light fixtures. Refurbish 6 chandeliers in auditorium, increase lighting. "|"1"|"1"|"S"|"1954"|"0"|"180,000"|"Replace existing PA, Intercom, clock systems. Upgrade and extend existing building security system. "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"5"|"0"||"1"|"COMMON"|"S"|"1954"|"5"|"0"||"1"|"COMMON"|"S"|"2006"|"10"|"0"||"0"|"INSTRUCT,COMMON"|"S"|"1924"|"5"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1924"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1924"|"15"|"317,900"|"Reconstruct areas of masonry deterioration to maintain envelope. Repair water table joints. Repair retaining wall adjacent to pond behind bleacher seating. "|"1"|"MASONRY"|"S"|"1924"|"15"|"30,000"|"Pointing needed. "|"1"|"MASONRY"|"S"|"1924"|"15"|"0"||"S"|"S"|"0"|"1"|"1954"|"5"|"76,000"|"Replace exterior doors at primary wing classrooms. Replace remaining exterior doors and hardware. "|"1"|"S"|"1954"|"15"|"35,000"|"Replace concrete steps and handrails at Auditorium, Gym and entrance G. Repoint exterior stairs. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1995"|"15"|"390,000"|"Replace original building windows. "|"METONMET,WOODONWOOD"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"5"|"747,500"|"Allowance for slate roof repairs. Upgrade downspouts to commerical grade. Remove cladding and restore cupola. Budget for complete slate replacement. "|"1"|"PLASTIC"|"S"|"1995"|"5"|"0"|"Need fall protection. "|"1"|"COPPER"|"S"|"1954"|"0"|"302,500"|"Provide hose bib at flag pole. BCS maintenance budget. "|"1"|"IRON,LEAD"|"S"|"1954"|"0"|"200,000"|"Budget to maintain plumbing drainage system. "|"1"|"NAT_GAS"|"S"|"2010"|"10"|"0"||"1"|"S"|"1996"|"0"|"276,000"|"ADA toilet at nurses office. Renovate primary wing classroom toilets. Upgrade primary wing sink cabinets/counters. Upgrade select plumbing fixtures. "|"0"||"1"|"BOILERSTEA"||"S"|"1996"|"26"|"25,000"|"Condsensate piping system modifications needed. "|"1"|"S"|"1996"|"26"|"0"|"Dual fuel, gas is primary."|"0"||||"125,000"|"Budget for Auditorium air conditioning. "|"1"|"S"|"1996"|"26"|"1,011,000"|"HV system for basement rooms. HV system for second and third floor rooms. Extend relief air system, 2nd and 3rd floors of 1930 building. Provide boiler room supply fan to alleviate overheating. Upgrade unit ventilators. "|"1"|"S"|"1954"|"0"|"25,000"|"Replace remote condensate receiver under kitchen area. "|"1"|"S"|"1954"|"0"|"0"|"Attic ductwork opened/bent from walking on, repairs needed. "|"1"|"S"|"1996"|"6"|"200,000"|"Reburbish hybrid pneumatic/DDC controls. Replace DDC ATC Andowver system. "|"1"|"S"|"1998"|"0"|"22,000"|"Confirm that all fans over 1000 CFM are on fan shutdown. Reconfirgure strbes and pull stations in Cafeteria. "|"1"|"S"|"1998"|"0"|"24,000"|"Replace smoke/heat detection system with fire alarm system. Provide additional fire alarm devices to meet ADA code. "|"1"|"S"|"1996"|"1996"|"20,000"|"Provide Ansul system over kitchen range. "|"1"|"S"|"1996"|"11"|"35,000"|"Provide additional emergency lighting throughout. Consider changing 2 exit signs in cafeteria. "|"0"||||"125,000"|"Budget for emergency generator. "|"1"|"1"|||"GOOD"||"GOOD"|"Combustible liquids in closet off gym should be stored properly. General clean up need at Mechanical room. Storage of a pallet of paper at top of gym stairs is a fire code concern. "|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"|"Most lighting systems replaced within last nine years. "|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"1"|"1"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"1"|"0"||"WARMING"|"1"|"0"|"0"|"FAIR"|"Proposed Bond Projects-New wing containing library, science room, art, compter room, 4th and 5th grade classrooms. New performing arts and music spaces. New cafeteria and kitchen addition. "|"6,437,650"|"S"|"1"|"TFMG Architecture, PC."|"P.O. Box 63, Bellport, NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, R.A. "|"021614"|"I ACCEPT"|12/20/2010 12:15:21 PM| 340|"Port Jefferson UFSD"|"58020602"|"Earl l. Vandermeullen High School"|"0001"|"10/07/2010"|"OLD POST ROAD "|"PORT JEFFERSON "|" 11777"|"ANNUAL"|"05/01/2011"|"1935"|"126500"|"3"|"9"|"1"|"DISTRICT"|"INSTRUCT"||"681"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"681"|"0"|"0"|||"27"|"20790"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"2"|"8500"|"S"|"1986"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"7"|"0"||"1"|"S"|"1995"|"12"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"12"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"12"|"1593000"|"Some locations require the following: Install additional retaining walls for drainage and erosion control which will require removal of trees and vegetation. Install drainage system which includes removing pea gravel for pipe installation."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1985"|"3"|"587956"|"Replace asphalt in & around custodial entrance. Possible replacement of asphalt at bus loop. Possible repavement of of faculty lot, upper pking lot behind Tech Ed bldg."|"1"|"CONCRETE"|"S"|"1996"|"5"|"98400"|"Sidewalk along bus loop should be replaced. Entire front entrance outside gym down to bus loop is in need of attention. A seperate study of this area needs to take place."|"0"||||"0"||"1"|"S"|"2010"|"12"|"87000"|"N"|"Recommend completeing drainage improvement to baseball field. Right side complete. Left side needs attention."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"12"|"0"|"Monitor retaining wall outside locker room."|"1"|"S"|"1965"|"20"|"0"||"1"|"S"|"1965"|"20"|"0"|"Continue to monitor interio cracks."|"1"|"S"|"2008"|"12"|"474456"|"Ceiling and lighting replacement needed throughout bldg. Recommend install of 2x2 acoustivcal ceilings, recessed lighting and occupancy sensors. ceiling in Music portable test positive for ACBM. Replace."|"1"|"E"|"1996"|"20"|"0"||"1"|"S"|"S"|"2008"|"15"|"44800"|"Many interior doors in need of replacement."|"1"|"S"|"1965"|"20"|"0"||"1"|"S"|"2008"|"4"|"0"|"Possibly install a full size 4000 ld elevator to HS."|"1"|"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"2008"|"10"|"0"|"NYSERDAlighting replacement projest scheduled for Summer 2011."|"1"|"1"|"S"|"1952"|"7"|"195000"|"Replace phone/communication system with a Bogen Quantum Multicom IP System. Replace existing Simplex clock system to new wireless battery operated system."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2007"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"12"|"241500"|"Overall condition of floors are in excellent condition however VAT tile have tested positive for asbestos at low priority 5 according to EPA. School may want to replace w/ VCT rubber cove base."|"1"|"COMMON"|"S"|"1956"|"25"|"0"||"1"|"INSTRUCT"|"S"|"2009"|"12"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"25"|"214800"|"Repair parapet adjacent to main entrance and parapet over boys locker room. Counterflashing height issues to be addressed when roof is replaced. Replace T-III & wood framing w/ masonry construction."|"1"|"MASONRY"|"S"|"2008"|"20"|"0"||"1"|"MASONRY"|"U"|"2008"|"3"|"0"|"Parapet at Boys' Locker Room Roof."|"S"|"S"|"1"|"1"|"2007"|"15"|"8000"|"Replace overhead door at Tech Ed."|"1"|"S"|"1960"|"6"|"22000"|"Replace deck boards on 5 landings and 12'x86" stair treads with new 3x6 treads and 3x8 decking on the platforms."|"1"|"S"|"1"|"1935"|"12"|"25000"|"Recommend wire brush scrape, inspect all welds and paint."|"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1986"|"15"|"316260"|"Test perimeter caulking of reamining windows which were not replaced during the window replacement for asbestos and PCB's."|"METONMET,WOODONWOOD,WOODONMET,CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1992"|"5"|"0"|"Recommend replacement of roof over Boys Locker Room. Insallation of window film to reduce up to 65% of solar gain and provide 99% UV protection."|"1"|"PLASTIC"|"S"|"1992"|"5"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1960"|"7"|"0"||"1"|"IRON"|"S"|"1960"|"10"|"0"||"1"|"OIL"|"S"|"2001"|"12"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"E"|"2008"|"30"|"125000"|"replace 10,000 CFM Lennox Warm Air Furnace serving the Industrial Arts Bldg. Provide & Install new elec power necessary to operate unit."|"1"|"E"|"2008"|"30"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"S"|"2008"|"17"|"0"||"1"|"S"|"2004"|"8"|"119000"|"Replace vacuum condensate pump located in the Annex Mech Room. Replace sump pump below gym. Monoitor asbestos pipe wrap."|"1"|"S"|"2007"|"15"|"0"|"New system installed in renovated library."|"1"|"S"|"1957"|"5"|"563000"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1970"|"1970"|"0"||"1"|"S"|"1999"|"7"|"0"||"0"||||"245000"|"Request was made to install a 100KW gas fired emergency generator. Essential services include security system, comm systems, FA System, Heating System, Food storage, Ejector pump & parts of lighting system."|"0"|"0"|"445500"|"Handicapped accessibility to be addressed. Need wheelchair accessible drinking fountains.ADA avccess to football field and baseball field."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|||"0"|"0"||"FULL"|"1"|"1"||"FAIR"||"5505672"|"U"|"1"|"John A. Grillo Architect PC"|"1213 Main Street, Port Jefferson "|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/20/2010 12:48:09 PM| 341|"Avoca CSD"|"57020104"|"Bus Barn Maint"|"5011"|"11/18/2009"|"East Ave"|"Avoca, NY"|" 14809"|"ANNUAL"|"08/01/2011"|"1950"|"18672"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Storage, Maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"2"|"2000"|"S"|"1990"|"15"|"0"||"1"|"MUN_UTILIT"|"E"|"2007"|"30"|"0"||"1"|"SITESEPT"|"E"|"2008"|"30"|"0"||"1"|"E"|"2007"|"37"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2008"|"38"|"0"||"1"|"E"|"2007"|"30"|"0"||"0"||||"0"||"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"1"|"SURFACEH2O,ONSITE"||"0"|"S"|"1990"|"15"|"0"|"Outfall under DEC jurisdiction."|"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"ASPHALT"|"S"|"2007"|"20"|"0"||"1"|"CONCRETE"|"E"|"2007"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2008"|"75"|"0"||"1"|"E"|"2008"|"50"|"0"||"1"|"S"|"2008"|"50"|"0"||"1"|"S"|"2008"|"25"|"0"||"0"|"S"|"2008"|"25"|"0"||"1"|"E"|"E"|"2008"|"25"|"0"||"1"|"E"|"2008"|"50"|"0"||"0"||||"0"||"1"|"1"|"E"|"2008"|"28"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"1"|"S"|"2008"|"18"|"20000"|"Intrusion detection system: 20 devices with cabling and head end equipment."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2008"|"40"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2008"|"50"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2008"|"15"|"10000"|"Overhead door hardware/safety switch & panels are failing. repair damaged/non-functioning overhead doors."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,OTHER"|"E"|"NA"|"2008"|"30"|"0"||"OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"30"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2007"|"37"|"0"||"1"|"IRON"|"E"|"2007"|"37"|"0"||"1"|"NAT_GAS"|"E"|"2005"|"12"|"0"||"1"|"E"|"2007"|"27"|"0"||"0"||"1"|"OTHER"||"E"|"2007"|"15"|"0"||"1"|"E"|"2007"|"20"|"0"||"0"||||"0"||"1"|"E"|"2007"|"20"|"0"||"0"||||"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"18"|"0"||"0"||||"0"||"1"|"E"|"2008"|"18"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"|"0"|"GOOD"||"39000"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Susan Mehr"|"018634"|"I ACCEPT"|12/20/2010 2:01:31 PM| 343|"Harrison CSD"|"66050106"|"Harrison High School"|"0011"|"10/06/2010"|"255 Union Avenue"|"Harrison"|" 10528"|"ANNUAL"|"03/01/11"|"1973"|"168,657"|"2"|"11"|"0"|"DISTRICT"|"INSTRUCT"||"993"|"9,10,11,12"|"0"|"0"|"1"|"993"|"0"|"0"|||"33"|"28,018"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,TEACHRSRC,TECHSHOP"||"1"|"1"|"1500"|"0"|"0"|"S"|"1996"|"5"|"175,000"|"Existing tank is too small. Replace with 20,000 gallon above ground double walled fiberglass tank. Existing system has oil level to monitor. "|"1"|"MUN_UTILIT"|"S"|"1973"|"13"|"75,000"|"Additional site fire hydrants to comply with NYS code per BCSR. "|"1"|"MUN_UTILIT"|"S"|"1973"|"13"|"0"|"Continue to monitor and maintain. "|"1"|"S"|"1996"|"36"|"0"|"Continue to monitor and maintain. "|"1"|"UTIL"|"BELOW"|"S"|"1973"|"13"|"465,000"|"Provide field lighting for Varsity baseball/Varsity softball field. Replace deteriorated site lighting wiring/damaged lights and poles, and provide additional, as needed. "|"1"|"S"|"1973"|"10"|"0"||"0"||||"0"||"1"|"S"|"1973"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"0"|"235,000"|"Provide exterior directional signage. Provide additional onsite parking and create a second exit from the west corner of the property. "|"1"|"CONCRETE,ASPHALT"|"S"|"1973"|"15"|"16,500"|"Replace localized cracked and deteriorated sections of sidewalk. Replace concrete landing at west wing stairwell. "|"0"||||"0"||"1"|"S"|"2006"|"15"|"840,000"|"Y"|"Renovate and provide irrigation for lower varsity football field. Rehabilitate lower soccer field as per the BCSR. Provide a new 1,200 sq ft storage building for track/football/sports equipment. Provide a half size field turf practice field. "|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"||"1"|"S"|"1973"|"15"|"35,000"|"Fire stop all wall and floor penetrations. Main transformer room requires fire stopping. Monitor cracks on wall. "|"1"|"S"|"1973"|"15"|"8,000"|"Point cracking of masonry walls in main entry corridor and repaint. Brace partitions in Boy's bathroom, adjacent to gym to prevent racking. Repair/replace damaged/missing wall tiles. "|"1"|"S"|"1973"|"5"|"738,500"|"Ceiling replacement. "|"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"S"|"1973"|"10"|"160,500"|"Ongoing door replacements. Replace/update door closers as required. Fire rated doors required in select areas. "|"1"|"S"|"1973"|"15"|"83,000"|"Replace 1 open riser communicating stair. Replace side guardrails at auditorium tiered seating to meet code. Loose handrail outside main office. "|"1"|"S"|"1997"|"10"|"0"||"0"|"1"|"S"|"1973"|"13"|"405,500"|"Provide electric box/panel covers where needed. Rebalance existing panels and replace main breakers as needed. Provide electric hand dryers in all gang toilets. Relocate interior transformers. GFCI needed in select areas. "|"1"|"S"|"1993"|"8"|"175,000"|"Provide additional lighting in gym. Replace missing/broken light fixtures and add occupancy sensors. "|"1"|"1"|"S"|"1993"|"2"|"0"|"Upgrade technology infrastructure."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1973"|"5"|"0"||"1"|"COMMON"|"S"|"1973"|"5"|"35,000"|"Repair terrazzo settling in A corridor. Men's and Women's lavatory off Auditorium has floor tile settling. "|"1"|"COMMON"|"S"|"1973"|"10"|"0"|"Gym and stage have wood flooring. Plywood and masonite flooring in Planeterium. "|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"Point wall adjacent to corridor settlement one location. "|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"173,000"|"Repair/replace/repoint masonry where required. Joint sealants. Remove/replace exterior caulking where deteriorated. Repair cracks in exterior stucco soffits. Courtyard stone walls are in bad condition, remove or repair. "|"1"|"MASONRY"|"S"|"1973"|"15"|"7,500"|"Provide chimney cap on boiler chimney. "|"0"|||||"0"||"S"|"S"|"0"|"0"|"1973"|"0"|"10,500"|"Replace door at transformer vault. Paint/repair/replace shop room doors. "|"1"|"S"|"1973"|"15"|"22,500"|"Provide two new staircases from upper tennis courts down to fields."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1973"|"0"|"642,500"|"Window replacement. Possible 34 windows egress-able. Replace rusted exterior panels at Art room. "|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"6"|"10,000"|"Replace gutters along small gym. Open pitch pocket conduit needs repair. Blue Duron pipe vents for science labs are not flashed in properly, will eventually leak. "|"1"|"PLASTIC"|"S"|"1996"|"6"|"0"|"Install fall protection. "|"1"|"COPPER"|"S"|"1973"|"13"|"50,000"|"Repair/replace leaking shut off valves and provide additional valves as required. "|"1"|"IRON,COPPER"|"S"|"1973"|"13"|"195,000"|"Provide rooftop vent caps on all plumbing vents to prevent vandalism. Repair/replace acid waste piping in science rooms. "|"1"|"OIL,NAT_GAS"|"S"|"1996"|"16"|"5,000"|"Preform repairs to piping/re-circulating pumps. "|"1"|"S"|"1973"|"12"|"101,000"|"Replace broken and/or missing bathroom fixtures, accessories, sinks and drinking fountains. Upgrade custodial slop sinks to floor sinks. Recommend kitchen sinks have indirect drains. "|"0"||"1"|"BOILERWATE"||"S"|"1973"|"1"|"750,000"|"Replace 2 original Otto water tube boilers, including controls, circulator pumps, valves, boiler room piping. "|"1"|"S"|"1996"|"0"|"0"||"1"|"S"|"1973"|"36"|"50,000"|"Replace band/orchestra unit and 2 large DX condensing units. "|"1"|"S"|"1973"|"13"|"1,040,000"|"Mechancial upgrades throughout. Replace/repair or provide new ventilation/exhaust fans at gym, boiler room, print room. "|"1"|"S"|"1973"|"13"|"50,000"|"Repair/replace hot water isolation valbes through building. "|"1"|"S"|"1973"|"13"|"107,500"|"Reconfigure new gym system. Clean all ductwork. Supply air ductwork and registers in gym and weight room. Repair HVAC #6 vibration isolation cloth tear. "|"1"|"S"|"1996"|"11"|"150,000"|"Systems requires pneumatic rehab. Incorporate district wide DDC control connections over a Fiber WAN. Provide additional heating zones. "|"1"|"S"|"2008"|"5"|"225,000"|"Replace/update original Simplex zoned system. "|"1"|"S"|"1973"|"0"|"0"|"System is working, should be replaced/updated to currect standards. "|"1"|"S"|"1996"|"1996"|"5,000"|"Be sure fire extinguishers are provided and in working order where required. Fire extinguisher on roof needs inspection update. Provide fire extinguisher on stage and Auditorium fan room. "|"1"|"S"|"1993"|"8"|"40,000"|"Upgrades in planetarium and select rooms. Boys side gym and Kitchen consider/add emergency lighting. Extend emergency lighting into Library work rooms and storage rooms on first and second floors. "|"1"|"S"|"1973"|"6"|"150,000"|"Replace/upgrade existing generator to extend to gym, cafeteria and kitchen. "|"1"|"1"|"160,000"|"Provide ADA compliant signage throughout building. Provide ADA modifications to select toilets on each floor and nurse's office. Girls room opposite 218 ADA stall needs grab bar. "|"GOOD"|"Corridor at gym/wrestling blocked by storage. "|"GOOD"|"All combustible materials should be stored properly."|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"1"|"1"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Repair outside air arrangements for Cafeteria, and Library areas. "|"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"1"|"0"|"FIREALARM,LIGHTING"|"FULL"|"0"|"1"||"FAIR"|"Proposed Projects: New science wing with class and lab space. Renovated classrooms, new main lobby/stairs. Expanded music and art program space. Renovated technology areas, and upgraded Cafeteria. "|"7,391,500"|"S"|"1"|"TFMG Architecture, PC."|"P.O. Box 63, Bellport, NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, R.A."|"021614"|"I ACCEPT"|12/20/2010 2:50:16 PM| 345|"Allegany - Limestone CSD"|"04030206"|"Bus Garage"|"5014"|"08/11/2010"|"3498 Maple Avenue"|"Allegany"|" 14706"|"ANNUAL"|"07/01/2011"|"2005"|"37179"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus Storage and Maintenance"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2005"|"15"|"0"||"1"|"MUN_UTILIT"|"E"|"2005"|"15"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20+"|"0"||"0"||||"0"||"1"|"MUNI,ONSITE"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2005"|"15"|"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2005"|"10"|"0"|"Monitor minor cracking."|"0"||||"0"||"1"|"S"|"1984"|"5"|"0"|"N"|"Playfiends used by elementary school; bleachers should be removed."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"20+"|"1950"||"1"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"15"|"0"||"0"||||"0"||"1"|"E"|"E"|"2005"|"15"|"0"||"1"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"20+"|"0"||"1"|"1"|"E"|"2005"|"15"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"1"|"E"|"2005"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"5"|"0"||"1"|"COMMON"|"E"|"2005"|"10"|"0"||"1"|"COMMON"|"S"|"2005"|"20"|"0"|"Reseal bus wash and maintenance area."|"0"|||||"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2005"|"20+"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2005"|"20+"|"2600"|"Minor repointing at roof ladders and openings."|"0"|||||"0"||"1"|"MASONRY"|"E"|"2005"|"20+"|"0"||"E"|"E"|"0"|"1"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"E"|"NA"|"2005"|"15"|"0"||"METONMET,OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Roof drains need to be cleared of debris."|"E"|"2005"|"15"|"0"||"1"|"GLASS"|"E"|"2005"|"20"|"0"||"1"|"COPPER"|"E"|"2005"|"20+"|"0"||"1"|"IRON,COPPER"|"E"|"2005"|"20+"|"0"||"1"|"NAT_GAS"|"E"|"2005"|"10"|"0"||"1"|"E"|"2005"|"20"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2005"|"20"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"20"|"0"||"1"|"E"|"2005"|"20+"|"0"||"1"|"E"|"2005"|"2005"|"0"||"1"|"E"|"2005"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Ceiling"|"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"0"|"E"|"0"|"Kideney Architects, PC"|"200 JJ Audubon Pkwy"|"716-636-9700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/20/2010 4:22:44 PM| 346|"Schodack CSD"|"49150104"|"Maple Hill Middle School"|"0004"|"06/15/2010"|"1477 S. Schodack Road"|"Castleton-on-Hudson"|" 12033"|"ANNUAL"|"01/01/2011"|"1960"|"88,789"|"1"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"233"|"6,7,8"|"0"|"0"|"1"|"233"|"0"|"0"|||"20"|"16,206"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"10"|"0"||"1"|"SITESEPT"|"S"|"1997"|"10"|"0"|"1000 & 5000 Gallon tanks"|"1"|"S"|"1997"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"5"|"0"|"Installed on existing building"|"1"|"E"|"2007"|"20"|"0"||"0"||||"0"||"1"|"E"|"1997"|"20"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"E"|"2008"|"20"|"0"|"Added additional rip/rap"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT"|"E"|"2007"|"15"|"0"|"1/2 the parking lot."|"1"|"CONCRETE"|"E"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20"|"17,000"|"N"|"Renovated basketball courts 2009; regrading of softball field required"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"|"Existing lav wall finishes replaced in 2008"|"1"|"S"|"2008"|"10"|"0"|"New drop ceiling in computer and library wings"|"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"|"Used lift installed at stage"|"1"|"1"|"S"|"2008"|"15"|"0"|"Replaced 1966 transformer and distribution panels"|"1"|"S"|"2008"|"10"|"0"|"Replaced lighting fixtures in library and computer rooms 2008"|"1"|"1"|"E"|"2008"|"15"|"0"|"Added new phone/PA throughout building/clocks"|"0"||||"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"|"Replaced carpet in computer lab/library"|"1"|"INSTRUCT,COMMON"|"S"|"1997"|"15"|"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"|"Replaced lavatory floor tiles"|"1"|"INSTRUCT"|"S"|"1997"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"0"||"1"|"MASONRY"|"S"|"1997"|"0"|"0"|"No longer used for boiler venting"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"8"|"20,000"|"Replace exterior loading dock doors"|"1"|"S"|"2008"|"20"|"0"|"Replaced loading dock steps 2008"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"15"|"0"|"windows replaced in 1960 wing"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"15"|"0"|"50% of roof covered in spray foam roof system 2008"|"1"|"PLASTIC"|"S"|"2008"|"15"|"0"||"1"|"COPPER"|"S"|"1997"|"15"|"0"|"Replaced Misc. Galvinized in 2008"|"1"|"IRON"|"S"|"1997"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1997"|"7"|"0"|"Replaced 100 gallon hot water heater (summer) flue 2008"|"1"|"S"|"2008"|"15"|"0"|"Replaced fixtures in (4) restrooms used by students"|"0"||"1"|"BOILERWATE"||"E"|"2008"|"15"|"0"|"Installed (4) new hot water boilers and piping 2008"|"1"|"S"|"2008"|"15"|"0"|"Gas, partial"|"1"|"S"|"2008"|"10"|"0"|"New split AC roof top unit at computer room"|"1"|"E"|"2008"|"15"|"0"|"Installed new UV's and opened OA intakes on existings"|"1"|"S"|"2008"|"10"|"0"|"Replaced (2) boiler waterpumps 2008"|"1"|"S"|"1997"|"10"|"0"||"1"|"E"|"2008"|"10"|"0"|"New controls for 4th & 5th grade wing"|"1"|"E"|"2008"|"15"|"0"|"New alarm system throughout"|"1"|"E"|"2008"|"15"|"0"|"Added new smoke and heat detectors 2008"|"1"|"S"|"1997"|"1997"|"0"||"1"|"E"|"2008"|"15"|"0"|"Added new emergency Lighting and exit signage 2008"|"1"|"E"|"2008"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"0"|"0"|"GOOD"||"37,000"|"S"|"0"|"Stieglitz Snyder Architecture"|"425 Franklin Street"|"716-828-9166"|"psnyder@stieglitzsnyder.com"|"Philip Snyder"|"21279"|"I ACCEPT"|12/20/2010 4:24:27 PM| 347|"Harrison CSD"|"66050106"|"Louis M. Klein Middl School"|"0003"|"09/24/2010"|"50 Union Avenue"|"Harrison"|" 10528"|"ANNUAL"|"03/01/2011"|"1939"|"166325"|"3"|"11"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"||"825"|"6,7,8"|"0"|"1"|"0"|"825"|"0"|"0"|||"37"|"27695"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"1"|"5000"|"0"|"0"|"S"|"1996"|"5"|"180000"|"Above ground tank in basement steel/carbon steel is too small. Provide new outside/underground tank. Provide/install containment dike around existing tank with leak detection system. "|"1"|"MUN_UTILIT"|"S"|"1957"|"0"|"75000"|"Provide fire hydrants on per BCSR. "|"1"|"MUN_UTILIT"|"S"|"1957"|"0"|"135000"|"Continue to monitor and maintain. Replace sanitary line out to Union which backs up into building."|"1"|"S"|"1957"|"0"|"42500"|"Continue to monitor and maintain. Provide automatic gas shut off's at science rooms and relocate gas meter from basement to outside. "|"1"|"UTIL"|"BELOW"|"S"|"2001"|"35"|"2000"|"Provide chain link enclosure at transformer. "|"1"|"S"|"1939"|"10"|"0"||"1"|"S"|"1939"|"10"|"0"|"Side parking storm drainage dishcharges into stream. "|"1"|"S"|"1939"|"10"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1939"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1939"|"10"|"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1957"|"15"|"235000"|"Resurface asphalt parking areas and expand as required. Provide concrete curbing and drainage basins along east side of parking lot. "|"1"|"CONCRETE,ASPHALT"|"S"|"1957"|"15"|"30000"|"Replace damaged sections of walkways as needed. "|"0"||||"0"||"1"|"S"|"1957"|"15"|"660000"|"N"|"Renovate softball/soccer/little league fields & add bleachers as needed. Provide/replace site fence at property line. Replace existing cinder track with new all weather metric tack & field. Re-plumb flagpole; recaulk joints in base. "|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1939"|"15"|"500"|"Repatch leaking foundation wall patch at boiler room."|"1"|"S"|"1939"|"15"|"98400"|"Firestop at various locations. Remove/replace select door & louver lintels. Patch holes & waterproof basement walls at meter room. "|"1"|"S"|"1939"|"15"|"566075"|"Replace folding partions. Remove/replace breezeway storefront/doors. Provide acoustic panels. Repair CMU. Replace select casework/tiles. Repaint interior classrooms/plaster repairs. Infill non-functioning step lights. ADA mirrors needed in select areas. "|"1"|"S"|"1939"|"5"|"100000"|"Replacement of classroom ceilings. "|"1"|"S"|"2009"|"15"|"0"|"Dead end locker bank corridors were eliminated in 2006. Boys 'A' & Girls 'A; locker rooms have new lockers and finishes. "|"1"|"S"|"S"|"1995"|"5"|"456500"|"Upgrade/re-hang doors from courtyard/gym. Install smoke doors/magnetic door holders & panic hardware on select doors. Correct select corridor pocket conditions. Upgrade/remove/replace doors throughout. Upgrade hardware to ADA hardware throughout. "|"1"|"S"|"1939"|"15"|"7000"|"Replace boiler room stair rail/mezzanine to bring to code. Provide additional railing/curbing to wheelchair ramp at main entrance. "|"1"|"S"|"1996"|"15"|"60000"|"Refurbish frieght elevator, cage, controls and motor. "|"1"|"1"|"S"|"1996"|"35"|"341500"|"Replace older distribution panels. Provide covers & locks for panels. Relocate panel at room 106. Replace non-functioning fans. Provide electric hand dryers. GFCI needed. Stage needs 2 light switch covers. "|"1"|"S"|"1994"|"9"|"145000"|"Replace lighting in 2nd floor corridor/classrooms/auditorium. Upgrade select lighting. Provide occupancy sensors. Replace toggle switches. "|"1"|"1"|"S"|"2001"|"16"|"45000"|"Budget to upgrade technology systems. "|"1"|"U"|"2004"|"2"|"965000"|"Total upgrade of pool. Add dehumidification capability and heat recovery. Active water leaks seeping into pool perimeter storage area. "|"1"|"INSTRUCT"|"S"|"1996"|"5"|"8000"|"Replace carpet in faculty room. "|"1"|"INSTRUCT"|"S"|"1996"|"5"|"134000"|"Replace deteriorated VCT at CSEA. VAT floor replacements. "|"1"|"COMMON"|"S"|"1996"|"15500"|"5"|"Replace heaved area of quarry tile. Remove/replace flooring in band room. "|"1"|"INSTRUCT"|"S"|"1996"|"5"|"60000"|"Sand/refinish wood floors at original building classrooms. "|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1939"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1957"|"15"|"446100"|"Reconstruct masonry deterioration to maintain building envelope. Remove/clean/reinstall/reset select lintels. Removed raised planter. Reset/repoint coping. Paint steel fame & canopy brackets. Repair damaged EIFS at mods. "|"1"|"MASONRY,METAL"|"S"|"1996"|"15"|"13000"|"Recommend Flue cap. "|"1"|"MASONRY"|"S"|"1939"|"15"|"0"|"Capped with galvanized copings. "|"S"|"S"|"0"|"1"|"1996"|"5"|"14000"|"Replace cafeteria exterior doors with FRP. Kitchen rated walls have non labeled doors & remaining fire closers are not working. New courtyard egress being done. Door to roof fan from fan room nees to be replaced. "|"1"|"S"|"1957"|"15"|"103750"|"Reconstruct select sections. Replace all non-code railings. Repair concrete at exterior stairway at rear of library. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"1279000"|"Replace window systems deemed necessary. Replace all glass block window systems. Replace aluminum damaged fascia. "|"METONMET,CONMETMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1996"|"5"|"3077575"|"Repair roof leaks. Provide vandal resistant plumbing vent covers. re-roof entry canopies. Replace flat roof. Glass block window joints need repair/replacement. Clean roof of tree debris. "|"1"|"PLASTIC"|"S"|"1996"|"5"|"35750"|"Provide fall protection. "|"1"|"GALVANIZED,COPPER"|"S"|"1954"|"0"|"100000"|"Replace all galvanized piping. "|"1"|"IRON,COPPER"|"S"|"1939"|"0"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"5"|"0"||"1"|"S"|"1939"|"0"|"293000"|"Provide ADA alterations. Repair loose faucets throughout. Replace urinals & original fixtures not yet replaced. Replace Dwyer combo unit. "|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1996"|"0"|"175000"|"Budget to provide A/C unit for auditorium. "|"1"|"S"|"1954"|"0"|"1603250"|"Provide/replace unit drivers/motors in select areas. Re-open all classroom louvers. Provide additional ventilation. Rebuild/replace air handling units. Replace select exhaust fans. "|"1"|"S"|"1954"|"0"|"213000"|"Provide radiator enclosures. Replace radiator covers. Repair/replace leaks. Remove/replace electric heat. Insulate steam piping. Reinsulate all piping after asbestos abatement. Replace cast iron radiators/controls. "|"1"|"S"|"1954"|"0"|"104500"|"Clean/sanitize ductwork. Provide new dampers. Replace grill. Replace damaged crawlspace louvers. "|"1"|"S"|"1996"|"5"|"275000"|"Expand system to all equipment/pneumatic system. Controls are DDC and pneumatics. "|"1"|"S"|"2000"|"10"|"12000"|"Provide vandal resistant guards for fire alarm. Remove old fire alarm equipment. "|"1"|"S"|"2000"|"10"|"14000"|"Provide heat/smoke detection in select areas. "|"1"|"S"|"1996"|"1996"|"0"|"Over due fire extinguisher tags noted. "|"1"|"S"|"2008"|"10"|"900"|"Add exit/emergency lights in select areas. "|"0"||||"0"||"1"|"1"|||"GOOD"|"Clear brush/overgrowth from brook area- $5000"|"GOOD"|"General refurbish, repair, paint new benches of all gym locker rooms- $112000. Replace all stage curtains & rigging-$50000. Refubish house in auditorium-$75000"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"1"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"1"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"1"|"0"||"FULL"|"0"|"1"||"FAIR"|"Proposed bond prject include science labs, improved classroom environments, new music rooms, renovated art rooms/corridor, expanded cafeteria & reconfigured building into 3 houses. "|"12585000"|"S"|"1"|"TFMG Architechture, PC"|"P.O. Box 63 Bellport NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, RA"|"021614"|"I accept"|12/20/2010 4:48:16 PM| 348|"North Bellmore UFSD"|"28020402"|"Martin Avenue Elementary School"|"0002"|"07/29/2010"|"2616 Martin Avenue"|"North Bellmore"|" 11710"|"ANNUAL"|"4/1/2010"|"1948"|"50,057"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"306"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"306"|"0"|"0"|||"20"|"15500"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1987"|"10"|"19,000"|"School is to perform routne maintenance. Replace existing fuel oil tank monitoring & overfill alarm systems."|"1"|"MUN_UTILIT"|"S"|"1948"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1948"|"10"|"0"||"1"|"S"|"1950"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"|"School is to perform routine maintenance & ensure storm drain system is free of all blockage."|"0"||||"0"||"1"|"S"|"2000"|"10"|"0"|"School District shall perform annual cleanouts on all existing catch basins & ensure proper."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"3"|"227,000"|"Asphalt pavement in Admin Parking Lot in need of complete replacement also partial replacement in play areas & Basketball Court."|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"5"|"37,000"|"Majority of walkways cracked & propose tripping hazard-recommend replacement to match w/new."|"1"|"S"|"2001"|"15"|"0"|"Existing playgrounds in good condition & are ADA accessible."|"1"|"S"|"1950"|"5"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"25"|"0"||"1"|"S"|"2000"|"10"|"0"|"Various interior cracks w/in existing plaster walls appear to be non-structural in nature. Cracks should be monitored."|"1"|"S"|"2000"|"10"|"0"|"School to monitor hazardous non-structural cracks."|"1"|"S"|"2000"|"5"|"400,000"|"Majority of building glued 12x12 concealed spline ceilings directly to plaster-school to replace."|"0"||||"0"||"1"|"S"|"S"|"2000"|"15"|"0"|"Still several doors original to building & are being addressed as part of Bond-summer 2011."|"1"|"S"|"1996"|"10"|"0"|"Original risers in good condition"|"1"|"S"|"1996"|"15"|"0"|"Continue annual inspections & maintenance"|"1"|"0"|"S"|"2000"|"5"|"60,000"|"Provide addiitonal sub-panels & outlets to meet District's Tech needs."|"1"|"E"|"2010"|"15"|"0"||"1"|"1"|"S"|"2000"|"5"|"125,000"|"Replace existing PA/Intercom/Clock System throughout building w/new."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"0"|"Existing carpet in Library & CPU Room in good shape."|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"15"|"0"|"All original VAT floor tiles have been removed."|"1"|"INSTRUCT"|"S"|"1948"|"10"|"0"|"Painted concrete floors are in good shape. Regular mainenance to be by Owner."|"1"|"INSTRUCT"|"S"|"1948"|"15"|"0"|"All existing wood floors are in good shape-Owner shall continue regular maintenance."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"0"|"MASONRY"|"E"|"2010"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1996"|"10"|"0"|"The main entrance doors are to be replaced as part of this Bond Issue."|"1"|"S"|"2000"|"10"|"20,000"|"Steps in good condition but not ADA compliant. Recommend replacement "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"18"|"0"|"School to ensure all existing roof drains are free & clear of debris."|"1"|"PLASTIC"|"S"|"2008"|"18"|"0"||"1"|"COPPER"|"S"|"2000"|"15"|"0"||"1"|"IRON,GALVANIZED"|"S"|"2000"|"15"|"0"||"1"|"OIL"|"S"|"1996"|"5"|"0"|"Existing hot water system is adequate. Maintenance service & annual inspection."|"1"|"S"|"1950"|"5"|"354,000"|"F&I ADA accessible work spaces & sink minimum 1/classroom/grade level. Recommend conversion of toilet to ADA accessible."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1948"|"2"|"0"|"To be replaced summer 2011"|"1"|"S"|"1948"|"2"|"0"|"To be replaced summer 2011"|"1"|"S"|"2000"|"5"|"0"|"Window A/C units"|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1950"|"10"|"0"|"Existing convectors are in good shape."|"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1950"|"5"|"94,000"|"Pneumatic controls in need of rehabilitation. Recommend all UV's be refurbished & new DDC central control panel be installed."|"1"|"S"|"2001"|"10"|"15,000"|"Existing wall mounted Fire Alarm pull stations be lowered to 54" height."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"2000"|"0"|"Existing Fire Supression System is fine-Owner is to maintain w/annual inspections & maintenance."|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"1"|"0"|"0"|"Majority of interior doors do not contain any accessible hardware."|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"School is to perform routine maintenance on all ventilation equipment & filters."|"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"1"|"0"||||"0"|"0"||"FULL"|"0"|"1"||"FAIR"||"1,351,000.00"|"S"|"0"|"JOHN A. GRILLO ARCHITECT PC1"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/20/2010 4:53:47 PM| 349|"Allegany - Limestone CSD"|"04030206"|"Allegany-Limestone Middle/High School"|"0008"|"08/11/2010"|"3131 Five Mile Road "|"Allegany"|" 14706"|"ANNUAL"|"07/01/2011"|"1999"|"185310"|"3"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"693"|"6,7,8,9,10,11,12"|"0"|"0"|"1"|"693"|"0"|"0"|||"36"|"29412"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP,OTHER"|"District Offices"|"0"||||||||"0"||"1"|"WELL"|"S"|"1999"|"15"|"0"||"1"|"SITESEPT"|"S"|"1999"|"15"|"0"||"1"|"E"|"1999"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"E"|"1999"|"15"|"0"||"1"|"MUNI"||"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT,GRAVEL"|"S"|"2009"|"5"|"0"||"1"|"CONCRETE"|"U"|"2009"|"2"|"219895"||"0"||||"0"||"1"|"S"|"1999"|"2"|"479830"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2001"|"20"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"15"|"2600"||"1"|"E"|"E"|"2009"|"20+"|"0"||"1"|"E"|"1999"|"20+"|"0"||"1"|"E"|"1999"|"20+"|"0"||"1"|"1"|"E"|"1999"|"20+"|"0"||"1"|"E"|"2009"|"10"|"0"||"1"|"1"|"E"|"2009"|"10"|"0"||"1"|"E"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"||"1"|"COMMON"|"S"|"1999"|"15"|"1105"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"15"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2009"|"20+"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"1"|"MASONRY"|"E"|"1999"|"20+"|"0"||"1"|"MASONRY"|"E"|"2009"|"20+"|"0"||"E"|"E"|"0"|"1"|"2001"|"20+"|"0"||"1"|"S"|"1999"|"20"|"1170"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"20+"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"10"|"65000"||"1"|"GLASS"|"E"|"1999"|"20+"|"0"||"0"|"COPPER"|"E"|"2009"|"20+"|"0"||"1"|"IRON,COPPER"|"E"|"2009"|"20+"|"0"||"1"|"NAT_GAS"|"E"|"1999"|"15"|"0"||"1"|"E"|"1999"|"20"|"0"||"0"||"1"|"BOILERWATE"||"E"|"1999"|"20"|"0"||"1"|"E"|"1999"|"20+"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"E"|"1999"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"E"|"1999"|"20+"|"0"||"1"|"E"|"1999"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"1999"|"1999"|"0"||"1"|"E"|"2009"|"10"|"0"||"1"|"E"|"1999"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"0"|"E"|"0"|"Kideney Architects, PC"|"200 JJ Audubon Pkwy"|"716-636-9700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/20/2010 5:06:15 PM| 350|"Rochester City SD"|"26160001"|"John Williams School #5"|"0005"|"08/27/2010"|"555 PLYMOUTH AVENUE "|"ROCHESTER "|" 14608"|"ANNUAL"|"06/01/2011"|"1926"|"132630"|"3"|"4"|"1"|"DISTRICT"|"INSTRUCT"||"559"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"0"|"559"|"0"|"0"|||"48"|"32209"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1926"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1926"|"25"|"0"||"1"|"S"|"1926"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"35"|"30,000"|"Add pole mounted site lighting at north parking lot"|"1"|"S"|"1989"|"20"|"0"||"0"||||"0"||"1"|"S"|"1989"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"4"|"102,000"|"Full depth reconstruction of west parking areas along Verona St. "|"1"|"CONCRETE"|"S"|"2008"|"5"|"82,000"|"Replace sidewalk along Verona Street and south of building "|"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"1"|"1"|"1"|"0"|"S"|"1926"|"45"|"0"||"1"|"S"|"2000"|"45"|"0"||"1"|"S"|"2000"|"45"|"0"||"1"|"E"|"2003"|"10"|"0"||"0"||||"0"||"1"|"E"|"E"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"45"|"0"||"1"|"1"|"S"|"1997"|"5"|"20,000"|"Replace remaining obsolete secondary panelboards"|"1"|"S"|"2004"|"15"|"0"||"1"|"1"|"S"|"2000"|"10"|"80,000"|"Replace master clock and secondary clocks "|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2003"|"15"|"0"||"SLABGRADE,OTHER"|"Structural tile and reinforced concrete"|"1"|"0"|"1"|"0"|"1"||"0"|"0"|"1"|"S"|"1926"|"45"|"0"|"Temporary shoring of 1st floor slab, repair to damaged column"|"MASONRY"|"1"|"1"||"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"45"|"0"||"1"|"METAL"|"S"|"1988"|"20"|"0"||"1"|"MASONRY"|"S"|"1988"|"201988"|"0"||"E"|"E"|"1"|"1"|"2006"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1"|"1993"|"3"|"37,700"|"Repair 2 riser concrete at south of building Replace stairs at northeast entrance"|"1"|"ALUMINUM"|"E"|"Y"|"2010"|"25"|"0"|"Current window replacement"|"OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"0"||"S"|"1997"|"10"|"0"||"1"|"GLASS"|"S"|"1997"|"10"|"0"||"1"|"COPPER"|"S"|"1996"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1996"|"20"|"6,000"|"Provide backwater check valves"|"1"|"NAT_GAS"|"S"|"2007"|"10"|"0"||"1"|"S"|"1996"|"5"|"218,500"|"Replace fixtures"|"1"|"CV"|"1"|"BOILERSTEA"||"E"|"2009"|"34"|"0"||"1"|"S"|"2009"|"19"|"0"||"1"|"S"|"2009"|"15"|"18750"|"Add airconditioning to data closet 221"|"1"|"S"|"2005"|"15"|"123,000"|"1. Add general exhaust to art room and home EC Room - $32,250 2. Replace exhaust fan systems - $20,850 3. Add ventilation to (7) rooms - $70,000 "|"1"|"S"|"2009"|"5"|"131,715"|"1Steam traps require replacement piping system requires flushing and cleaning. Replace boiler room condensate pump2 Replace condensate pump in boiler room 3Radiators with convectors and radiation 4Radiation convectors 5Insulate exposed heating piping"|"1"|"S"|"2008"|"30"|"33,125"|"1. Clean supply ductwork in main office suite - $2500 2. Clean toilet exhaust ductwork 3. Provide exhaust ductwork to custodial closets $13,125 4. Provide new exhaust distribution in girl's toilet 106A - $7500"|"1"|"S"|"2009"|"10"|"1750"|"The toilet room 104A exhaust fan into DDC system"|"1"|"S"|"2000"|"10"|"250,000"|"Replace fire alarm system in its entirety; add strobes to classrooms "|"1"|"S"|"2000"|"10"|"0"|"Replace fire alarm system in its entirety; add strobes to classrooms "|"1"|"S"|"1960"|"1960"|"5000"|"add an ansul system to kitchen hood"|"1"|"S"|"2004"|"15"|"45,000"|"revise designated corridor lighting to be on emergency, replace/add bldg. mounted lighting at exit discharge"|"1"|"S"|"2003"|"15"|"200,000"|"Add additional automatic transfer switch to seperate life safety equipment and upsize to pick ip emergency lighting and additional heating plant, add exit, discharge lighting to emergency."|"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"1,601,515"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/20/2010 5:11:01 PM| 352|"Frankfort-Schuyler CSD"|"21040206"|"MIDDLE/HIGH SCHOOL"|"0001"|"07/20/2010"|"605 PALMER ST"|"FRANKFORT"|" 13340"|"ANNUAL"|"06/30/2011"|"1928"|"134,134"|"3"|"10"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"659"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"659"|"0"|"0"|||"33"|"26,200"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"50"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"35"|"0"||"1"|"S"|"2000"|"50"|"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"15"|"10,000"|"limited areas of repair"|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"30"|"0"||"1"|"U"|"E"|"2002"|"40"|"80,000"|"replace 1928 doors and frames-other doors are satisfactory"|"1"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"20"|"65,000"|"Replace VAT in 7 spaces"|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"40"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"1"|"0"||"S"|"2000"|"50"|"20,000"|"Area of water penetration at upper wall behind gym"|"1"|"METAL"|"S"|"2002"|"40"|"0"||"1"|"MASONRY"|"S"|"1928"|"40"|"0"||"E"|"E"|"1"|"1"|"2009"|"20"|"0"||"1"|"S"|"1928"|"30"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"30"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"0"||"1"|"PLASTIC"|"S"|"2002"|"15"|"0"|"plastic and glass -cracks"|"1"|"GALVANIZED,COPPER"|"S"|"2002"|"30"|"70,000"|"replace valves in 1928 wing"|"1"|"IRON,GALVANIZED,PVC"|"S"|"2002"|"30"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"20"|"35,000"|"replace/upgrade faucets, flush valves & convert drinking fountians to coolers"|"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"2002"|"10"|"120,000"|"replace 1983 era unit ventilators"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"10"|"250,000"|"add ac to auditorium"|"1"|"S"|"2002"|"20"|"275,000"|"replace 1928 and 1983 era equipment"|"1"|"S"|"2002"|"40"|"0"||"1"|"S"|"1983"|"15"|"0"||"1"|"S"|"2000"|"10"|"200,000"|"convert remaining pnuematics to DDC (trane tracer)"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS,OTHER"|"misc ceilings"|"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"1,350,000"|"S"|"0"|"William Taylor Architects"|"6432 Baird Ave Syracuse NY 13206"|"315-432-0901"|"Bill.taylor@taylor-architects.com"|"William f. Taylor"|"015512"|"I accept"|12/21/2010 9:32:56 AM| 353|"Frankfort-Schuyler CSD"|"21040206"|"REESE ROAD ELEMENTARY SCHOOL"|"0002"|"07/20/2010"|"610 REESE RD"|"FRANKFORT"|" 13340"|"ANNUAL"|"06/30/2011"|"1962"|"51,000"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"315"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"1"|"315"|"0"|"0"|||"24"|"21,992"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"20"|"0"||"1"|"S"|"1962"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"30"|"0"||"0"||||"0"||"1"|"S"|"2002"|"30"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"30"|"0"||"1"|"S"|"1962"|"30"|"0"||"1"|"S"|"1962"|"30"|"0"||"1"|"S"|"2009"|"20"|"30,000"|"replace various ceiling areas"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"S"|"2009"|"20"|"0"||"1"|"S"|"1962"|"30"|"0"||"0"||||"0"||"1"|"1"|"S"|"1983"|"10"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2007"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"10"|"0"||"1"|"COMMON"|"S"|"1962"|"30"|"300,000"|"replace VAT in 36 spaces"|"1"|"INSTRUCT"|"E"|"2009"|"30"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"30"|"0"||"1"|"MASONRY"|"S"|"1962"|"30"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"30"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"30"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"15"|"0"||"1"|"PLASTIC"|"S"|"2007"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1962"|"15"|"25,000"|"replace origianl 1962 valving"|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1962"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1983"|"3"|"20,000"|"replace"|"1"|"S"|"1983"|"5"|"75,000"|"upgrade fixtures"|"0"||"1"|"BOILERWATE"||"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"U"|"1983"|"5"|"650,000"|"replace complete system"|"1"|"S"|"1983"|"5"|"0"|"pumps replaced in 2009"|"1"|"S"|"1983"|"5"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"2000"|"20,000"|"add ansul system to kitchen"|"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||"WARMING"|"0"|"1"||"GOOD"||"1,300,000"|"U"|"0"|"William Taylor Architects"|"6432 Baird Ave Syracuse NY 13206"|"315-432-0901"|"Bill.taylor@taylor-architects.com"|"William F. Taylor"|"015512"|"I accept"|12/21/2010 10:00:40 AM| 354|"Harrison CSD"|"66050106"|"Preston Elementary School"|"0007"|"09/29/2010"|"55 Taylor Avenue"|"West Harrison"|" 10604"|"ANNUAL"|"03/01/2011"|"1932"|"68715"|"4"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"344"|"K,1,2,3,4,5"|"0"|"0"|"0"|"344"|"0"|"0"|||"18"|"15261"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"1"|"2000"|"0"|"0"|"S"|"1996"|"35"|"150000"|"Exisiting tank in basement vault is too small. Provide 10000 gallon underground tank, per BCS. "|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"115000"|"Provide back flow preventor on fire standpipe. Provide fire hydrants on site. "|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"0"|"Continue to monitor and maintain."|"1"|"S"|"1996"|"35"|"0"|"Continue to monitor and maintain. LL5 Electric/Gas Room: gas valve has no handle in room to close valve in an emergency. "|"1"|"UTIL"|"BELOW"|"S"|"1996"|"35"|"64000"|"Provide OSHA approved lock-out hardware on main switch. Provide (6) additional security lights. Remove/reconstruct utility wires. Reattach (4) fixtures. Rebuild deteriorated electric service grounds. "|"1"|"S"|"1932"|"5"|"30000"|"Provide additional site drainage adjacent area and improve site drainage to alleviate flood ongoing. "|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"5"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1996"|"5"|"12000"|"Budget to replace asphalt entry walkway, curbing/road gutter and walks. "|"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1996"|"15"|"250000"|"N"|"Budget to rehabilitate play fields & provide irrigation system."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1932"|"15"|"4500"|"Budget to repair cracks in retaining walls. "|"1"|"S"|"1932"|"15"|"7500"|"Budget for fire stopping. "|"1"|"S"|"1932"|"15"|"17000"|"Budget to repair plaster damage/scrape, paint and clean select walls. "|"1"|"S"|"1996"|"15"|"45000"|"Budget to repair/replace ceilings in select areas. "|"1"|"S"|"1954"|"5"|"0"||"1"|"S"|"S"|"1996"|"15"|"245000"|"Budget to replace/relocate/upgrade/recongfigure/install select doors. Provide door closers, ADA locksets and hold open devices. "|"1"|"S"|"1932"|"15"|"0"||"1"|"S"|"1932"|"15"|"0"||"1"|"1"|"S"|"1996"|"35"|"263000"|"Budget to install shunt trip on power elevator, provide electrical distribution to select areas, balance/provide/replace panels, provide hand dryers and GFCI's."|"1"|"S"|"1994"|"8"|"147000"|"Budget to add lighting, sensors &controls. "|"1"|"1"|"S"|"2009"|"9"|"95000"|"Provide new stage sound system/clock system. Upgrade/extend security system. "|"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"5"|"87000"|"Budget to replace VAT & refinish select floors. Install floor expansion joint. "|"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1932"|"15"|"2500"|"Replace concrete slab at entry alcove of 1996 addition. "|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1996"|"15"|"83000"|"Replace concrete walls. Paint steel lintles. Repair cracks and repoint. Replace masonry and mortar. Repair expansion joints. "|"1"|"MASONRY"|"S"|"1996"|"15"|"15000"|"Budget for pointing of masonry. "|"1"|"MASONRY"|"S"|"2006"|"15"|"0"||"S"|"S"|"0"|"1"|"1996"|"0"|"73000"|"Replace all doors with FRP doors. "|"1"|"S"|"1932"|"15"|"19400"|"Provide handrails and guardrails. Repair stone steps. "|"1"|"S"|"1"|"1996"|"15"|"18000"|"Remove rust, prepare and paint. Perform regular preventative maintenance. "|"1"|"ALUMINUM"|"S"|"Y"|"1982"|"0"|"623650"|"Budget for full window replacement. "|"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"S"|"1998"|"5"|"1500"|"Provide scupper and leader. "|"0"|||||"0"||"1"|"COPPER,LEAD"|"S"|"1996"|"0"|"150000"|"Monitor and maintain. Not all replaceable. "|"1"|"IRON"|"S"|"1932"|"0"|"250000"|"Monitor and maintain. Not all replaceable. "|"1"|"NAT_GAS"|"S"|"2010"|"10"|"0"||"1"|"S"|"1996"|"0"|"51000"|"Budget to replace select plumbing fixtures. Provide indirect drains at kitchen food prep sinks. "|"0"||"1"|"BOILERSTEA"||"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"0"|"0"||"1"|"S"|"2000"|"2"|"125000"|"Provide A/C in Auditorium. "|"1"|"S"|"1932"|"0"|"952500"|"Provide mechanical fresh air & exhaust. Repair/replace Gym/Auditorium AHU units, fan & grill. Restore exhaust system. Provide/install exhaust in toilet rooms. Provide boiler room ventilation. Refurbish unit ventilators."|"1"|"S"|"1996"|"25"|"5000"|"Insultat and enclose 10 unit ventilator steam lines. "|"1"|"S"|"1932"|"0"|"65000"|"Clean and sanitize all ductwork. "|"1"|"S"|"1996"|"5"|"195000"|"Refurbish pneumatic/DDC. Increase budget to upgrade to complete DDC controls. "|"1"|"S"|"1996"|"10"|"48500"|"Provide magentic hold open devices. Confirm fans are fan shutdown. Correct various fire alarm deficiencies. "|"1"|"S"|"1996"|"10"|"19500"|"Provide/add smoke detectors. "|"1"|"S"|"2000"|"2000"|"7500"|"Provide fire extinguisher cabinets. Replace existing fire shutter with motorized shutter. "|"1"|"S"|"2000"|"15"|"5000"|"Provide wire guards to select lights. Add signs to select areas. "|"0"||||"125000"|"Budget for new 75kva emergency generator. "|"1"|"1"|||"GOOD"|"Allowance for additional equipment in Kitchen servery.-$15000. Second floor 'K' wing has toaster oven in classroom; not recommended. Remove tables from exit aisle in auditorium balcony. Gym mat storage in exit corridor needs to be removed. "|"GOOD"|"Provide new storage building on site-$100000"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"1"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"FAIR"|"Previously mentioned areas to be renovated to add ventilation air. "|"0"|"1"|"1"|"1"|"1"|"1"|"0"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"1"|"0"||"WARMING"||"1"||"FAIR"|"Proposed bond project includes new additions containing classrooms/support space. Improved core classroom environment, direct access to main office etc. Expand performing arts & music spaces. New construction $5.9 mil"|"4485050"|"S"|"1"|"TFMG Architechture, PC "|"P.O. Box 63 Bellport NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, RA"|"021614"|"I accept"|12/21/2010 10:25:36 AM| 355|"Frankfort-Schuyler CSD"|"21040206"|"WEST FRANKFORT ELEMENTARY"|"0006"|"07/20/2010"|"160 SCHOOL LANE"|"FRANKFORT"|" 13340"|"ANNUAL"|"06/30/2011"|"1963"|"51,000"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"245"|"K,1,2,3,4,5"|"0"|"1"|"1"|"245"|"0"|"0"|||"20"|"21,000"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"20"|"0"||"1"|"SITESEPT"|"S"|"1999"|"20"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1983"|"10"|"0"||"0"||||"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"10"|"30,000"|"localized repairs"|"1"|"CONCRETE"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1963"|"30"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1963"|"50"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"S"|"2001"|"5"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"E"|"2009"|"20"|"0"||"1"|"S"|"1963"|"25"|"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1963"|"10"|"300,000"|"Abate VAT in 50 spaces"|"1"|"INSTRUCT,COMMON"|"S"|"1963"|"30"|"0"||"1"|"INSTRUCT"|"E"|"2009"|"20"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"0"|"MASONRY"|"S"|"1963"|"20"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"30"|"0"||"1"|"S"|"1963"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1983"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"15"|"0"||"1"|"PLASTIC"|"S"|"1999"|"15"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"1963"|"20"|"35,000"|"replace valving install mixing valve at hot water tank"|"0"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"1963"|"20"|"0"||"0"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"1963"|"10"|"70,000"|"replace fixtures"|"0"||"1"|"BOILERWATE"||"E"|"2009"|"30"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"1983"|"5"|"650,000"|"replace entire system"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"1983"|"5"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS,OTHER"|"misc ceilings"|"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"|"FRIDGE"|"WARMING"||"1"|"0"|"GOOD"||"1,400,000"|"S"|"0"|"William Taylor Architects"|"6432 Baird Ave Syracuse NY 13206"|"315-432-0901"|"bill.taylor@taylor-architects.com"|"William F. Taylor"|"015512"|"I accept"|12/21/2010 10:29:21 AM| 356|"Rochester City SD"|"26160001"|"Dr. Charles Lunsford School #19"|"0019"|"08/13/2010"|"465 SEWARD STREET "|"ROCHESTER "|" 14608"|"ANNUAL"|"07/2010"|"1971"|"84732"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"337"|"Pre-K,K,1,2,3,4,5,6,7"|"0"|"1"|"0"|"337"|"0"|"0"|||"39"|"31056"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,RSRCEROOM,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1971"|"25"|"0"||"1"|"S"|"1971"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"20"|"93,6000"|"Light pole base removal, replace building mounted luminaires replace pole mounted lights"|"1"|"S"|"1999"|"25"|"0"||"0"||||"0"||"1"|"S"|"1999"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1999"|"5"|"47,125"|"Resurface asphalt parking lot and asphalt near loading dock, replace guard bar, replace curbing at locations"|"1"|"CONCRETE,ASPHALT"|"U"|"1999"|"5"|"67,470"|"sidewalk replacement/asphalt removal/replace brut pavers at south and west side of building"|"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"45"|"27,560"|"N"|"Fence replacement at 4' and 6'height/ replace timber"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"45"|"0"||"1"|"S"|"1971"|"45"|"0"||"1"|"S"|"2005"|"45"|"0"||"1"|"S"|"2005"|"10"|"0"|"Original ceilings - 1971 - 5 year life"|"0"||||"0"||"0"|"S"|"S"|"2005"|"15"|"0"|"Change doors to B/C label, Replace with fire rated doors remove toe kick door stops"|"1"|"S"|"1971"|"45"|"0"||"1"|"S"|"1971"|"45"|"0"||"1"|"1"|"S"|"1971"|"10"|"195,000"|"Replace obsolete secondary panelboards and MDP"|"1"|"S"|"2004"|"10"|"0"||"1"|"1"|"S"|"1995"|"10"|"55,000"|"Replace master and secondary clocks"|"0"||||"0"||"1"|"INSTRUCT"|"E"|"2008"|"10"|"0"|"Second/first floor carpet - satisfactory - 2 year useful life"|"1"|"COMMON"|"E"|"2005"|"10"|"0"||"1"|"COMMON"|"S"|"1971"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"45"|"0"|"Repair damager concrete frame at penthouse door "|"CONCRETE"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"45"|"9,750"|"Provide water repelent to precast panel. Replace retaining wall coping and railing at rear of play area. "|"0"|"METAL"|"S"|"2002"|"15"|"0"||"1"|"METAL"|"S"|"1971"|"45"|"0"||"S"|"S"|"0"|"1"|"2005"|"10"|"0"|"Replace HM doors to stair tower, replace exterior door"|"1"|"S"|"2005"|"15"|"1,300"|"repair loading dock stair"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"0"|"Replace fixed window on 1st and 3rd floor and horizontal pivot windows. Remove inact seveels at rescue window locations "|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1989"|"10"|"0"|"rescue/replace drain baskets"|"0"|||||"0"||"1"|"COPPER"|"S"|"1972"|"45"|"0"||"1"|"IRON,COPPER"|"S"|"1972"|"45"|"0"||"1"|"NAT_GAS"|"S"|"1998"|"10"|"0"||"1"|"S"|"2005"|"5"|"23,000"|"Replace misc. fixtures, flush valves and faucets "|"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2002"|"27"|"0"||"1"|"S"|"2002"|"45"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1999"|"5"|"33,800"|"Replace 6 sidewall toilet EF's "|"1"|"S"|"2002"|"32"|"0"||"1"|"S"|"1999"|"10"|"2000"|"replace room 307 vav box "|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1991"|"5"|"170,000"|"Replace entire fire alarm system. Lacking coverage in classrooms and corridors "|"1"|"S"|"1991"|"1991"|"0"||"1"|"S"|"2004"|"10"|"10,000-25,000"|"Put exit discharge lighting on emergency. Add emergency lights in corridors "|"1"|"S"|"1971"|"5"|"200,000"|"Replace generator and add heating plant, seperate lire safety and equipment"|"1"|"1"|"5200"|"provide HC striping and signage"|"FAIR"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"stage "|"0"|||"1"|"1"|||"0"|"0"|"1"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"FAIR"||"1,455,875"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/21/2010 10:40:05 AM| 357|"Frankfort-Schuyler CSD"|"21040206"|"Maintenance Building"|"2011"|"07/20/2010"|"605 Palmer Street"|"Frankfort"|"13340"|"ANNUAL"|"06/30/2011"|"2003"|"2400"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"maintenance"|"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"50"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"50"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"30"|"0"||"0"||||"0"||"1"|"S"|"2003"|"30"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2003"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2003"|"35"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"35"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2003"|"30"|"0"||"1"|"GALVANIZED,PVC"|"S"|"2003"|"30"|"0"||"1"|"ELECTRIC"|"S"|"2003"|"10"|"0"||"1"|"E"|"2003"|"25"|"0"||"0"||"1"|"FURNACE"||"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"S"|"0"|"William Taylor Architects"|"6432 Baird Ave Syracuse NY 13206"|"315-432-0901"|"bill.taylor@taylor-architects.com"|"William F. Taylor"|"015512"|"I accept"|12/21/2010 10:48:22 AM| 358|"Port Jefferson UFSD"|"58020602"|"Relocatable"|"1009"|"10/04/2010"|"SCRAGGY HILL ROAD "|"PORT JEFFERSON "|" 11777"|"ANNUAL"|"05/01/2011"|"1967"|"8255"|"1"|"0"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1980"|"12"|"0"||"1"|"MUN_UTILIT"|"S"|"1985"|"12"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1980"|"12"|"0"||"1"|"S"|"1967"|"12"|"0"||"0"||||"0"||"1"|"S"|"1985"|"12"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"12"|"0"||"1"|"CONCRETE"|"S"|"2005"|"8"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"8"|"0"||"1"|"S"|"1967"|"12"|"0"||"1"|"S"|"1967"|"12"|"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"8"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"11"|"0"||"1"|"S"|"1997"|"9"|"0"||"1"|"1"|"S"|"1995"|"10"|"0"|"Tied into Elementary School."|"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"8"|"0"||"1"|"COMMON"|"S"|"1997"|"12"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"1"|"0"|"S"|"1967"|"8"|"0"|"Recommend a thorough inspection of sub-floor conditions."|"WOOD"|"0"|"1"||"1"|"1"|"0"|"1"|"1"||"S"|"1967"|"3"|"0"|"Recommend partial replacement of exterior clading take place in the next 2-3 years."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"12"|"0"||"1"|"S"|"2005"|"4"|"2200"|"Reconstruct stairs outside business office."|"0"|||||"0"||"1"|"VINYL"|"S"|"NA"|"1998"|"8"|"0"||"WOODONWOOD"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"0"|"1"||"U"|"1990"|"2"|"23000"|"Recommend replacement of flat roofs, gutters and all flashing."|"1"|"PLASTIC"|"S"|"1990"|"2"|"0"||"1"|"COPPER"|"S"|"1980"|"12"|"0"||"1"|"PVC"|"S"|"1980"|"12"|"0"||"1"|"ELECTRIC"|"S"|"1996"|"6"|"0"||"1"|"S"|"1967"|"10"|"0"||"0"||"1"|"OTHER"|"Electric"|"S"|"1967"|"10"|"0"|"Electric Heat"|"1"|"S"|"1967"|"10"|"0"|"Electric Heat"|"1"|"S"|"2000"|"8"|"0"|"Window A/C units."|"1"|"S"|"1980"|"4"|"0"|"Toilket exhaust only."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1996"|"12"|"0"||"1"|"S"|"1996"|"12"|"0"||"0"||||"0"||"1"|"S"|"1996"|"6"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"|"Minimal ductwork."|"0"|"1"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"1"|"1"||"FAIR"||"25200"|"U"|"1"|"John A. Grillo Architect PC"|"1213 Main Street, Port Jefferson "|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/21/2010 10:59:39 AM| 359|"North Bellmore UFSD"|"28020402"|"Newbridge Road Elementary School"|"0003"|"07/29/2010"|"1601 Newbridge Road"|"North Bellmore"|" 11710"|"ANNUAL"|"4/1/2011"|"1924"|"64,938"|"3"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"430"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"430"|"0"|"0"|||"21"|"15750"|"ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"10"|"19,000"|"Replace existing fuel oil tank monitoring & overall alarm system."|"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"|"School is to perform routine maintenance & ensure storm drain system is free of all debris."|"0"||||"0"||"1"|"S"|"1957"|"7"|"0"|"School district shall peform annual cleanouts of all existing catch basins & ensure proper function."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1957"|"5"|"10,000"|"Asphalt pavement condition is fair to poor-recommend replacement of existing asp halt pavement allowing water to flow away from building."|"1"|"CONCRETE,ASPHALT"|"S"|"1957"|"5"|"35,000"|"Partial sidewalk replacement required."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1957"|"3"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"20"|"0"||"1"|"S"|"1957"|"10"|"0"|"School to monitor all various non-structural cracks."|"1"|"S"|"1924"|"2"|"325,000"|"Interior plaster condition fair to poor due to constant water infiltration. "|"1"|"S"|"1957"|"5"|"590,651"|"Majority of ceilings are concealed spline & glued to non-asbestos plaster-recommend removal & replace w/new 2x2 fire rated acoustical ceilings."|"1"|"S"|"1954"|"10"|"0"||"1"|"S"|"S"|"1957"|"2"|"0"|"Interior door & hardware to be replaced summer 2011"|"1"|"S"|"1957"|"5"|"140,000"|"Recommend replacementof all interor stair railings, handrails & balustrades along 4 main stair towers"|"0"||||"0"||"0"|"0"|"S"|"2000"|"5"|"85,000"|"Provide addiitonal sub-panels & outlets to meet w/District Tech needs."|"1"|"E"|"2010"|"15"|"0"||"1"|"1"|"S"|"1996"|"5"|"190,000"|"Replace existing PA/Intercom/Clock System throughout building w/new."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"5"|"0"|"Carpet in existing Library is in fair condition"|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"5"|"268,520"|"Overall condition of VAT is good to fair-recommend District plan for replacing existing VAT on priority basis."|"1"|"INSTRUCT"|"S"|"1957"|"10"|"0"|"All existing concrete & tile floors are in good shape. Regular maintenance by Owner."|"1"|"INSTRUCT"|"S"|"1997"|"10"|"0"|"Existing floor in good shape-require maintenance be done by Owner."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"0"||"1"|"MASONRY"|"S"|"2008"|"3"|"0"||"1"|"MASONRY"|"S"|"2008"|"20"|"0"||"S"|"S"|"0"|"1"|"1996"|"5"|"15,000"|"Several pairs of doors are in need of replacement that have been damaged & vanalized over the years."|"1"|"S"|"1957"|"10"|"0"|"Steps in good condition but not ADA compliant-recommend replacement of all steps to make all means of egress ADA accessible."|"1"|"S"|"1"|"1957"|"2"|"96,000"|"2 Exterior fire escapes should be scheduled for replacement-recommend both fire escapes be scraped & painted-School to monitor"|"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"||"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"1994"|"3"|"650,000"|"Recommend remove roofing w/ridge insulation flashing & metal copings - new roofing system installed."|"0"|||"1994"|"3"|"0"||"1"|"COPPER"|"S"|"1957"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1957"|"15"|"0"||"1"|"OIL"|"S"|"1996"|"15"|"0"||"1"|"S"|"1957"|"5"|"192,000"|"F&I handicapped accessible work space & sinks "|"1"|"CV"|"1"|"BOILERSTEA"||"U"|"1970"|"5"|"0"|"Replacement to take place summer 2011"|"1"|"S"|"1970"|"5"|"0"|"Replacement to take place summer 2011"|"1"|"S"|"1998"|"5"|"0"|"Window A/C unit"|"1"|"U"|"1957"|"1"|"0"|"All H&V units replaced as part of building-wide VAC upgrade summer 2011"|"1"|"U"|"1957"|"1"|"0"|"All piping convectors, etc. replaced as part of building-wide HVAC upgrade summer 2011"|"1"|"U"|"1957"|"1"|"0"|"All dampers, ductwork, etc. replaced as part of building-wide HVAC upgrade summer 2011"|"1"|"U"|"1957"|"1"|"0"|"New controls will be installed as part of building-wide HVAC upgrade summer 2011"|"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"1996"|"1996"|"0"|"Existing fire suppression system in Kitchen adequate. Owner to maintain w/annual inspections & maintenances."|"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"0"|"0"|"0"|"Basement egress-all buildings witghn District have valid CO. All corridors to be 6'-0". "|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"FAIR"||"3,116,171.00"|"U"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/21/2010 11:16:03 AM| 360|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #2-HEAVY EQUIPMENT "|"0044"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1968"|"13065"|"2"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"44"|"9,10,11,12"|"0"|"0"|"1"|"44"|"0"|"0"|||"2"|"2183"|"TECHSHOP"||"0"||||||||"0"||"1"|"WELL"|"S"|"1968"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1968"|"10"|"5,000"|"Provide exterior lighting. "|"0"||||"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"5"|"0"|"Slurry seal is needed."|"1"|"CONCRETE"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"15"|"1,000"|"Repair gap in the rated enclosure west stair. "|"1"|"S"|"1968"|"10"|"0"|"Interior finishes are old and need painting."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"S"|"1968"|"10"|"10,000"|"Fire door west of stair not rated (Mechanical Room). Replace door and hardware. "|"1"|"S"|"1968"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"3"|"2,000"|"Replace outdated panels, provide dust-proof covers for receptacles in tech. areas. "|"1"|"S"|"1968"|"5"|"26,000"|"Replace with T8 fixtures, provide shielding for lamps in tech. areas. "|"1"|"1"|"S"|"2002"|"10"|"20,000"|"Provide new PA system. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Structural Concrete Deck"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1968"|"25"|"0"||"MASONRY"|"1"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"25"|"0"|"Cracks are visible in the exterior CMU throughout the building. "|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"||"1"|"S"|"2005"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"0"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"2"|"150,000"|"Building has tectum roof deck on metal joists."|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"1971"|"6"|"3,000"|"Replace sections of PVC."|"1"|"NAT_GAS"|"S"|"1971"|"2"|"3,000"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"1971"|"10"|"4,800"|"Replace faucet trim with metering faucets (6). "|"0"||"1"|"OTHER"||"S"|"2005"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"5,000"|"Replace toilet room exhaust. "|"0"||||"0"||"1"|"S"|"2005"|"10"|"20,000"|"Supply and return ductwork not rated."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"0"|"0"|"160,500"|"Add elevator, automatic door operator, and upgrade toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"FAIR"||"277,300"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/21/2010 11:27:14 AM| 361|"South Kortright CSD"|"12170204"|"Main Building"|"0003"|"10/20/2010"|"58200 State Highway 10"|"South Kortright"|" 13842"|"ANNUAL"|"12/29/2010"|"1939"|"31,128"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"385"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"16"|"5"|"0"|||"21"|"15,500"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"2006"|"20"|"0"||"1"|"WELL"|"S"|"2001"|"20"|"0"||"1"|"SITESEPT"|"S"|"2009"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1989"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"15"|"0"||"1"|"CONCRETE"|"S"|"2005"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"1939"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"20"|"0"|"minor repairs in areas"|"1"|"S"|"1939"|"25"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"6"|"200,000"|"miscellaneous areas throughout building"|"1"|"S"|"1989"|"5"|"80,000"|"replace 1939 corridor lockers (+/-200 lockers)"|"1"|"S"|"S"|"2009"|"5"|"100,000"|"ADA hardware, miscellaneous fire doors need to be brought up to code."|"1"|"S"|"1939"|"20"|"0"||"1"|"S"|"2009"|"25"|"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"0"|"S"|"2004"|"8"|"30,000"|"T-12 lamps in gymnasium need replacement"|"1"|"1"|"S"|"2004"|"6"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1989"|"8"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"7"|"0"|"areas in 1989 should be replaced."|"1"|"INSTRUCT"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2009"|"7"|"0"|"classrooms (1939) should be replaced $200,000. Gymnasium floor should be replaced $250,000."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1989"|"20"|"0"||"MASONRY"|"0"|"0"|"no"|"1"|"0"|"1"|"1"|"1"|"no"|"S"|"1989"|"5"|"60,000"|"control joints, joint raking, missing bricks, wood deterioration"|"1"|"MASONRY"|"S"|"1939"|"5"|"35,000"|"repointing and repair"|"1"|"MASONRY"|"S"|"1939"|"8"|"0"||"S"|"S"|"1"|"1"|"1989"|"5"|"140,000"|"exterior door replacement in majority of building"|"1"|"S"|"1989"|"5"|"30,000"|"repair and replacement of stairs (gym, rear of building, temp. classrooms)"|"0"|||||"0"||"1"|"ALUMINUM,WOOD"|"U"|"Y"|"1989"|"3"|"1,750,000"|"replacement of windows in majority of building"|"METONMET"|"SINGLEPLY,BUILTUP,SLATE"|"0"|"0"|"0"|"0"|"0"|"no"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"no"|"S"|"2009"|"5"|"90,000"|"slate tile needs repair. replace roof over 1989 temporary classrooms."|"1"|"PLASTIC"|"S"|"2009"|"5"|"0"||"1"|"GALVANIZED,COPPER,PVC"|"S"|"2009"|"15"|"0"|"no signs of systematic failures"|"1"|"IRON"|"S"|"1939"|"15"|"0"|"no issues reported. gravity to septic field."|"1"|"OIL"|"S"|"2000"|"5"|"20,000"|"HHW to dom. hw heat exchanger / storage tank some corrosion on pipe connections to unit."|"1"|"S"|"2009"|"20"|"0"|"All except 1989 done with exception of 1939 offices, nurse, and kitchen, coaches."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"2005"|"7"|"0"|"District office some window units, (2) 2005 classrooms u.v. w/split. elementary library 3 computer room - window units."|"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"2009"|"20"|"0"|"DDC - ALC (air temp) comprehension system"|"1"|"S"|"2005"|"10"|"5,000"|"currently no strobes in 1939 building classrooms"|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1990"|"1990"|"0"|"kitchen hood extinguishing system functional"|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2009"|"20"|"0"|"set up for portable generator for heat, water, select lights, kitchen"|"1"|"0"|"200,000"|"nurses suite, main office, ramp modifications to gymnasium bleachers, extis to exterior and area of refuge."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|"15,000"|"some cellulose ceiling tiles"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"1"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"HVAC"|"FULL"|"1"|"1"|"0"|"GOOD"||"3,000,000"|"S"|"1"|"SWBR Architects"|"4914 West Genesee Street, Camillus, NY 13031-2375"|"315-488-5635"|"fkoenig@swbr.com"|"Frederick Koenig"|"031617"|"I ACCEPT"|12/21/2010 11:40:07 AM| 363|"Rochester City SD"|"26160001"|"Enrico Fermi School #17"|"0017"|"07/29/10"|"158 ORCHARD STREET "|"ROCHESTER "|" 14611"|"ANNUAL"|"06/01/2011"|"1967"|"85464"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"557"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"0"|"497"|"60"|"0"|||"42"|"32135"|"ADMIN,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,PREK,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"45"|"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"45"|"0"||"1"|"S"|"2010"|"45"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"20"|"0"|"Add additional pole mounted site lighting"|"1"|"U"|"1995"|"0"|"45,500"||"0"||||"0"||"1"|"S"|"1999"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1999"|"2"|"0"|"Full depth reconstruction of asphalt pavement near loading and maintenance area"|"1"|"CONCRETE,ASPHALT"|"U"|"2008"|"1"|"112700"|"New asphalt sidewalk south of building. Replace concrete sidewalk adjacent to bus-dropoff."|"1"|"U"|"1999"|"4"|"168350"|"Replace play equipment and swings. Install new resliant play surface. "|"1"|"S"|"1967"|"15"|"0"|"N"|"Replace backstop"|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"45"|"0"|"Replace sealant"|"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"|"Paint various rooms, replace stairwell glazing"|"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1967"|"15"|"0"|"Replace various doors, provide closers"|"1"|"S"|"1967"|"45"|"0"||"1"|"S"|"1967"|"45"|"0"||"1"|"1"|"S"|"1999"|"15"|"0"|"Replace remaining obsolete secondary panelboards. "|"1"|"S"|"2004"|"15"|"0"|"Replace and add additional building mounted lighting "|"1"|"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"1997"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1997"|"15"|"0"||"1"|"COMMON"|"S"|"1967"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1967"|"10"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"45"|"0"||"MASONRY"|"0"|"0"||"1"|"1"|"1"|"0"|"0"||"S"|"1967"|"45"|"0"|"Repoint brick, seal cracks. portions of thin brick on portables has fallen off, large sections are in poor condition, some patched with hood"|"1"|"MASONRY"|"S"|"1967"|"5"|"0"|"Repair brick, conc. cap, tile flue "|"0"|||||"0"||"S"|"S"|"1"|"1"|"1967"|"5"|"0"||"1"|"S"|"1967"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2008"|"25"|"0"|"Rescue window releases are greater than 54" AFF"|"OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"0"||"S"|"2005"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2005"|"15"|"0"||"1"|"IRON"|"S"|"1967"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"5"|"0"|"Replace all original fixtures and classroom sinks"|"0"||"1"|"BOILERWATE"||"S"|"2005"|"25"|"0"|"Add gas detection system to boiler room"|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"5"|"0"|"1. Replace existing exhaust fans 2. Provide ventilation systems to 10 rooms"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1999"|"5"|"0"|"Replace fire alarm system in its entirety, add strobes to classrooms and bring up to code"|"1"|"S"|"1999"|"5"|"0"||"1"|"S"|"1974"|"1974"|"0"||"1"|"S"|"2008"|"20"|"0"|"Add lighting at exit discharge to emergency"|"1"|"S"|"2005"|"25"|"0"||"1"|"1"|"19500"|"Provide ADA accessible ramps and signs"|"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"|"Attached portable units"|"1,612,596"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/21/2010 11:46:14 AM| 364|"Port Jefferson UFSD"|"58020602"|"MAINTENANCE OPERATIONS BUILDING"|"2017"|"10/18/2010"|"SCRAGGY HILL ROAD"|"PORT JEFFERSON"|"11777-1980"|"ANNUAL"|"05/01/2011"|"1984"|"5000"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Locker Rooms / Toilets"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ADMIN"||"1"|"0"|"0"|"1"|"2000"|"E"|"2010"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1984"|"15"|"0"||"1"|"SITESEPT"|"S"|"1984"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1984"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1984"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1984"|"2"|"180000"|"asphalt pavement in and around O & M bldg needs to be replaced."|"1"|"ASPHALT"|"S"|"1984"|"6"|"0"||"0"||||"0"||"1"|"S"|"1984"|"8"|"8000"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1984"|"25"|"0"||"1"|"S"|"1984"|"20"|"0"||"1"|"S"|"1984"|"12"|"16000"|"Enlarge existing NOC to accomodate technology needs."|"1"|"S"|"2005"|"12"|"0"||"1"|"S"|"1984"|"15"|"0"||"1"|"S"|"S"|"1984"|"12"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1984"|"12"|"0"|"Didtrict server located within building."|"1"|"S"|"2005"|"12"|"0"||"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"8"|"0"||"1"|"COMMON"|"S"|"1984"|"9"|"0"||"1"|"COMMON"|"S"|"1984"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1984"|"25"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1984"|"20"|"0"||"1"|"METAL"|"S"|"1984"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1984"|"7"|"16000"|"Replace hollow metal doors and frames."|"0"||||"0"||"0"|||||"0"||"1"|"VINYL"|"S"|"NA"|"1984"|"12"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"1"||"U"|"1984"|"2"|"35000"||"0"|||||"0"||"1"|"COPPER"|"S"|"1984"|"15"|"0"||"1"|"IRON"|"S"|"1984"|"15"|"0"||"1"|"OIL"|"S"|"1984"|"3"|"5000"|"Recommend replacement with 2 electric hot water heaters 1 at each sink."|"1"|"S"|"1984"|"6"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1984"|"10"|"0"||"1"|"S"|"1984"|"10"|"0"||"1"|"S"|"2005"|"12"|"65000"|"Recommend complete reconfiguration of NOC with new A/C and 100% redundancy."|"1"|"S"|"1984"|"12"|"0"||"1"|"S"|"1984"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"1984"|"3"|"16000"|"Provide new addressable system - ADA upgrade."|"1"|"S"|"1984"|"3"|"0"||"0"||||"38,000"|"Provide new waterless fir suppression for NOC."|"0"||||"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"Minimal ductwork."|"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"226000"|"U"|"0"|"John A. Grillo Architect PC"|"1213 Main Street, Port Jefferson "|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/21/2010 12:10:00 PM| 365|"Southwestern CSD At Jamestown"|"06020106"|"Elementary"|"0011"|"10/13/2010"|"600 Hunt Road"|"Jamestown"|" 14701"|"ANNUAL"|"07/01/2011"|"2002"|"145990"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"644"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"1"|"644"|"0"|"0"|||"51"|"40440"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC"|"Cafe/Auditorium"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2002"|"40"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"|"Minor sink hole repairs recommended"|"0"||||"0"||"1"|"MUNI"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2002"|"10"|"0"|"Pavement shoulder repairs recommended. Entry drive reconsturct at Allegheny Ave."|"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"10"|"0.00"|"Minor sidewalk and curb repairs recommended"|"1"|"S"|"2002"|"10"|"0.00"|"Minor playground equipment repairs recommended"|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2002"|"40"|"0"|"Crackng, leaks, depsoits at foundation wall at pool, additional investigation required"|"1"|"E"|"2002"|"40"|"0"||"1"|"E"|"2002"|"15"|"0"||"1"|"E"|"2002"|"12"|"0"||"1"|"E"|"2002"|"10"|"0"||"1"|"E"|"E"|"2002"|"15"|"0"|"Wire glass installed in classroom doors and sidelights"|"1"|"E"|"2002"|"42"|"0"|"Wire glass in doors and sidelights, and landing windows "|"1"|"E"|"2002"|"12"|"0"||"1"|"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"S"|"2002"|"20"|"0"||"1"|"U"|"2002"|"5"|"150000"|"Repair pool pack controls, mechanical room ventilation is inadequate"|"1"|"INSTRUCT"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT"|"E"|"2002"|"7"|"0"||"1"|"COMMON"|"E"|"2002"|"42"|"0"|"Minor cracking in ceramic tile in isolated areas - corridors, toilet rooms, pool"|"1"|"INSTRUCT"|"S"|"2002"|"27"|"0"|"Gym floor - possible sub-moisture issue"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2002"|"40"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"E"|"2008"|"25"|"0"|"Replace sealant and backer ro at control joints, cut joints wider"|"1"|"MASONRY"|"E"|"2002"|"40"|"0"||"1"|"MASONRY"|"E"|"2002"|"40"|"0"||"E"|"E"|"0"|"1"|"2002"|"7"|"0"||"1"|"S"|"2002"|"40"|"0"|"Re-attach handrail at rear ramp"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2002"|"7"|"0"|"Based om assumed repairs of (2) units"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Minor leaks at library, bubbles in TPO membrane in various areas"|"S"|"2002"|"10"|"0"||"1"|"PLASTIC"|"E"|"2002"|"10"|"0"||"1"|"COPPER"|"S"|"2002"|"17"|"0"||"1"|"IRON,GALVANIZED,PVC"|"S"|"2002"|"12"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"17"|"0"||"0"||"1"|"BOILERWATE"|"Boiler / hot water as back-up"|"S"|"2002"|"12"|"0"|"Geo-thermal heat pumps"|"1"|"S"|"2002"|"17"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"|"Recommend adding exhaust to copy room and re-activate ERU's"|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"|"Several broken fire damper motor drives (3)"|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"||"Signage"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"1"|"POOR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"150000"|"S"|"1"|"Trautman Associates"|"470 Franklin Street, Buffalo, NY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M. Gehring"|"019087"|"I ACCEPT"|12/21/2010 12:50:01 PM| 366|"Southwestern CSD At Jamestown"|"06020106"|"Middle School"|"0006"|"10/13/2010"|"600 Hunt Road"|"Jamestown"|" 14701"|"ANNUAL"|"07/01/2011"|"1968"|"83600"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"346"|"6,7,8"|"0"|"1"|"1"|"346"|"0"|"0"|||"27"|"20990"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"40"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"|"Stabilization measures recommended at infiltration basin"|"1"|"S"|"1968"|"10"|"0"|"Replacement of D.I. recommended"|"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"15"|"0"|"Asphalt and shoulder repairs recommended"|"1"|"CONCRETE"|"U"|"2002"|"5"|"24000"|"Curb ramp slopes are non-compliant with Code"|"0"||||"0"||"1"|"S"|"1968"|"5"|"0"|"N"|"2-Fields may be regraded to create an improved facility"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"30"|"0"||"1"|"S"|"1968"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"E"|"2009"|"19"|"0"||"1"|"E"|"2007"|"17"|"0"||"1"|"E"|"E"|"2007"|"10"|"0"|"Replace stair storefront glazing with safety rated glazing. Replace interior gym doors."|"1"|"S"|"1968"|"30"|"0"|"Paint steel stringers"|"1"|"S"|"2009"|"15"|"0"||"1"|"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"1"|"S"|"2002"|"20"|"0"|"Recommend extending PA to High School - Middle School. Classes use High School classrooms"|"0"||||"0"||"1"|"INSTRUCT"|"E"|"2010"|"10"|"0"|"Varies; offices replaced 2010, library 2001"|"1"|"INSTRUCT"|"E"|"2009"|"14"|"0"||"1"|"COMMON"|"E"|"1968"|"20"|"0"||"1"|"INSTRUCT"|"E"|"1968"|"10"|"0"|"Gym floor refinished 2009"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"30"|"0"||"CONCRETE,MASONRY,STEEL,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2007"|"30"|"0"|"Repointing required in some areas, repair spalling precast panels"|"1"|"MASONRY,METAL"|"S"|"1968"|"30"|"0"|"Existing masinsonry with metal enclosure"|"0"|||||"0"||"E"|"E"|"0"|"1"|"2007"|"12"|"0"||"1"|"S"|"1968"|"30"|"0"|"Replace stairs and sidewalk at East stair"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2008"|"18"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Corrosion of communication tower guide wires"|"E"|"2009"|"24"|"0"|"Roof Construction - Gypsum on metal trusses/joist"|"1"|"PLASTIC"|"S"|"2009"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2008"|"8"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"1968"|"8"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"12"|"0"||"1"|"S"|"2008"|"18"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"|"Served from High School"|"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1968"|"8"|"0"||"1"|"S"|"2008"|"13"|"0"||"1"|"S"|"1993"|"5"|"0"|"Many alarm components old & nearing end of useful life"|"1"|"S"|"1993"|"5"|"0.00"|"Many detectors old & nearing end of useful life"|"1"|"S"|"2007"|"2007"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"1"||"Add signage identifying ADA toilet rooms and general room identification"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"24000"|"S"|"1"|"Trautman Associates"|"470 Franklin Street, Buffalo, NY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M. Gehring"|"019087"|"I ACCEPT"|12/21/2010 1:25:00 PM| 368|"Harrison CSD"|"66050106"|"Louis M. Klein Portable"|"0023"|"09/24/2010"|"50 Union Avenue"|"Harrison"|" 10528"|"ANNUAL"|"03/01/11"|"2001"|"8,000"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT"||"120"|"6,7,8"|"0"|"0"|"0"|"120"|"0"|"0"|||"8"|"8,000"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"25"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"25"|"0"|"120/208V 3 phase 4 wire 800 MDP with 600A main breaker. "|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2001"|"25"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"|"Provide ADA mirrors to both band room and music room lavatories. "|"1"|"S"|"2001"|"25"|"0"||"0"||||"0"||"1"|"S"|"S"|"2001"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"25"|"0"|"Label Classroom 301 as MDP Main Electric Disconnect. "|"1"|"S"|"2001"|"25"|"0"||"1"|"1"|"S"|"2001"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"2001"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"|"Repair pipe rail at ramp."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"25"|"0"|"Rescue window sticker needed at room 309."|"WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2001"|"25"|"0"||"1"|"COPPER"|"S"|"2001"|"25"|"0"||"1"|"ELECTRIC"|"S"|"2001"|"25"|"0"|"RUUD 50 gallon electric water heater. "|"1"|"S"|"2001"|"25"|"0"|"Provide ADA faucet and pipe wrap on both band room and music room lavatories. "|"0"||"1"|"OTHER"||"S"|"2001"|"25"|"0"|"Exterior wall packs."|"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"|"Exterior wall packs. "|"1"|"S"|"2001"|"25"|"0"|"Exterior wall packs and two roof exhaust fans. "|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"0"|"S"|||"0"||"1"|"S"|"2001"|"25"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"|"Remove cabinet from ADA bathroom in band room. Remove storage cabinet in music room. Clear birds nest from above mesh ceiling at ADA ramp area. "|"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"|||"0"|"1"||"FAIR"||"0"|"S"|"1"|"TFMG Architecture, PC."|"P.O. Box 63, Bellport, NY 11713"|"631-286-6046"|"info@thefmgrp.com"|"Richard Searles, R.A. "|"021614"|"I ACCEPT"|12/21/2010 2:11:58 PM| 370|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #3-INTRO CAREER MAJORS "|"0045"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"17101"|"2"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"43"|"9,10,11,12"|"0"|"0"|"1"|"43"|"0"|"0"|"GYM,OTHER"|"Shop Spaces"|"2"|"1600"|"TECHSHOP,OTHER"|"Weight Room, Staff Lounge, Break Room"|"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1970"|"1"|"0"||"1"|"CONCRETE"|"S"|"1970"|"1"|"150,000"|"Costs include concrete steps, handicap ramps and connecting sidewalks."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"1"|"S"|"1970"|"15"|"0"||"0"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"S"|"2000"|"2"|"2,000"|"Replace non-rated door between Shop and Corridor. "|"1"|"S"|"1968"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"2"|"5,000"|"Replace outdated panels, provide dust-proof covers for receptacles in tech. areas."|"1"|"S"|"1970"|"5"|"60,000"|"Replace existing with T8 fixtures, provide shielding for lamps in tech. areas. "|"1"|"1"|"S"|"2002"|"3"|"10,000"|"Provide new PA system. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"0"||"1"|"INSTRUCT"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1970"|"5"|"0"||"0"|"S"|"1970"|"1"|"0"|"Costs includes concrete steps, handicap ramps and connecting sidewalks. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"3"|"220,000"|"Seams and flashing starting to deteriorate. "|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"1971"|"5"|"3,000"|"Replace PVC piping with iron piping. "|"1"|"NAT_GAS"|"S"|"1971"|"2"|"3,000"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"1971"|"6"|"3,200"|"Replace faucet trim. "|"0"||"1"|"OTHER"||"S"|"2002"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"2"|"4,000"|"Replace exhaust hoses in the Shop. "|"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"0"|"0"|"1,075,000"|"Provide intermediate floor level for new kitchen, new elevator and upgraded toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"WARMING"|"0"|"0"|"0"|"GOOD"||"1,306,950"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/21/2010 2:45:47 PM| 371|"Harpursville CSD"|"03050104"|"Bus Garage"|"5008"|"10/20/2010"|"54 Main St."|"Harpursville"|" 13787"|"ANNUAL"|"11/01/2011"|"1941"|"14,568"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Vehicle Maintenance"|"0"|||"0"|"0"||||||"0"|"0"|||"1"|"0"|"0"|"1"|"6,000"|"S"|"1993"|"10"|"10,000"|"Replace Leak Detention System"|"1"|"WELL"|"S"|"1993"|"8"|"5,000"|"Replace pressure tank"|"1"|"SITESEPT"|"S"|"1993"|"7"|"0"||"0"||||"0"||"1"|"OTHER"|"BELOW"|"S"|"1993"|"20"|"0"|"Electrical feed from High School No reporteed problems"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1993"|"5"|"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1941"|"8"|"0"|"Portions of the original 1941 building are in need of repair."|"1"|"S"|"1941"|"10"|"0"||"1"|"S"|"1941"|"10"|"0"||"1"|"S"|"1993"|"10"|"0"|"There is very little suspended ceiling system in this facility."|"0"||||"0"||"1"|"S"|"S"|"1993"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1993"|"15"|"0"|"No reported problems"|"1"|"S"|"1993"|"15"|"0"|"Fluorescent lighting, no reported problems."|"1"|"0"|"U"|"1993"|"2"|"25,000"|"Currently part of High School system, replace and interface when High School system is upgraded."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1993"|"5"|"0"|"This finish is minimal but not aging well due to its use in a Bus Maintenance Facility."|"1"|"COMMON"|"S"|"1993"|"5"|"0"|"Concrete slab is aging as expected in a Maintenance Facility."|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"1"|"1"|"1"||"0"|"1"|"1"|"U"|"1941"|"5"|"36,000"|"Most of the structural slab is performing as expected. A small area in one bay is constructed of wood and shows signs of degradation."|"MASONRY,STEEL"|"1"|"0"|"None"|"1"|"0"|"0"|"1"|"1"||"S"|"1993"|"5"|"34,000"|"Portions of the original masonry is in need of repointing or replacement. Run-off from sloping roofs has caused masonry degradation."|"1"|"MASONRY"|"S"|"1941"|"15"|"0"||"1"|"MASONRY"|"U"|"1993"|"10"|"4,000"|"Portions of the exterior masonry parapet requires repointing and repainting."|"S"|"S"|"0"|"1"|"1993"|"10"|"25,000"|"Refinish all hollow metal 1993 doors and frames. Replace selective openings with new."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"U"|"NA"|"1993"|"5"|"80,000"|"The 1993 windows are performing as expected but the 1941 units require replacement."|"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"||"S"|"1993"|"5"|"0"|"Minor leaks regularly addressed by Owner. Primary concern is excessive run off at rear of building."|"0"|||||"0"||"1"|"COPPER"|"S"|"1993"|"15"|"15,000"|"Insulate selective piping."|"1"|"IRON,COPPER"|"S"|"1993"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2006"|"10"|"0"||"1"|"S"|"1993"|"10"|"6,000"|"Replace dated fixtures."|"0"||"1"|"BOILERSTEA"||"S"|"1993"|"15"|"2,000"|"Add backflow preventer to make up water line."|"1"|"S"|"1993"|"15"|"0"||"0"||||"0"||"1"|"U"|"1993"|"5"|"125,000"|"Add ventilation system to work and storage bays."|"1"|"S"|"1993"|"10"|"100,000"|"Insulate piping, replace steam traps and replace unit heaters."|"1"|"S"|"1993"|"15"|"0"||"1"|"S"|"1993"|"15"|"20,000"|"Expand DDC System to boiler plant."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"7,000"|"Add additional battery pack emergency lighting at exit discharge and replace exit lights."|"0"||||"0"||"0"|"0"|"36,000"|"Modifications to 1993 door, adjacent pavement and toilet rooms."|"POOR"||"POOR"||"0"|"0"|"FAIR"||"FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"POOR"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"1"|"0"|"FAIR"|"The Building is in fair to poor condition and the space is marginally adequate. The District would like to pursue a new facility in another location to address site circulation and safety concerns."|"$1,000,000"|"U"|"0"|"Ashley McGraw Architects, P.C."|"500 South Salina Street, Syracuse, NY 13202"|"315-425-1811"|"signorelli@ashleymcgraw.com"|"Nicholas Signorelli"|"024017"|"I ACCEPT"|12/21/2010 2:52:17 PM| 372|"Harrison CSD"|"66050106"|"Preston Portable"|"8017"|"09/29/10"|"Taylor Avenue"|"West Harrison"|" 10604"|"ANNUAL"|"03/01/11"|"1995"|"1610"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT"||"40"|"K,1,2,3,4,5"|"0"|"0"|"0"|"40"|"0"|"0"|||"2"|"1500"|"MUSIC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"19"|"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"19"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"1995"|"19"|"0"||"0"||||"0"|"See Samuel J Preston Elementary School report."|"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"|"Remove cabinet from Band ADA bathroom and provide ADA mirror also at Music room. "|"1"|"S"|"1995"|"19"|"0"||"0"||||"0"||"1"|"S"|"S"|"1995"|"19"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"||"1"|"1"|"S"|"1995"|"19"|"0"||"0"||||"0"||"0"|||||"0"||"0"|"INSTRUCT"|"S"|"1995"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1995"|"19"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"19"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"|"Repair pipe at rail. "|"0"|||||"0"||"1"|"VINYL"|"S"|"Y"|"1995"|"19"|"0"||"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"19"|"0"||"0"|||"1995"|"19"|"0"||"1"|"COPPER"|"S"|"1995"|"19"|"0"||"1"|"COPPER,PVC"|"S"|"1995"|"19"|"0"||"0"|||||"0"||"1"|"S"|"1995"|"19"|"0"|"Provide faucet and pipe wrap at Band ADA bathroom. Change slop sink to ADA lavatory. Provide ADA faucet and pipe wrap. "|"0"||"1"|"OTHER"||"S"|"1995"|"19"|"0"|"Thru-wall units. "|"1"|"S"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"|"Thru-wall units."|"1"|"S"|"1995"|"19"|"0"|"Thru-wall units."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1995"|"19"|"0"||"1"|"S"|"1995"|"19"|"0"||"0"||||"0"||"1"|"S"|"1995"|"19"|"0"|"Band room Portable #1 and 2 has exit signs out (4 each). Emergency lights also not working."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"|"Clear birds nest from above nest ceiling at ADA ramp area. "|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"|"0"|"GOOD"||"0"|"S"|"1"|"TFMG Architecture, PC."|"P.O. Box 63"|"63-286-6046"|"info@thefmgrp.com"|"Richards Searles, R.A."|"021614"|"I ACCEPT"|12/21/2010 3:07:59 PM| 373|"BOCES Albany-Schoh-Schen"|"01900000"|"Special Ed@ Rotterdam 1"|"8040"|"7/20/2010"|"941 River Road"|"Rotterdam Junction"|"12150"|"ANNUAL"|"10/1/2011"|"1969"|"6300"|"2"|"1"|"0"|"LSD_DIST"|"INSTRUCT"||"24"|"K,1,2,3,4,5"|"0"|"1"|"0"|"24"|"0"|"0"|||"0"|"0"|"ADMIN,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"15"|"0"||"1"|"SITESEPT"|"S"|"1969"|"15"|"0"||"1"|"S"|"1969"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1969"|"15"|"0"|"Remaining life based on visual assessment."|"0"||||"0"||"1"|"S"|"1969"|"15"|"0"|"Surface drainage"|"0"||||"0"||"0"||||"0"||"0"|"SURFACEH2O"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"15"|"0"||"1"|"CONCRETE"|"S"|"1969"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1969"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1969"|"15"|"0"|"Minor cracking visible - appears to be shrinkage related (non-structural). Caulk to minimize water penetration."|"1"|"S"|"1969"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"|"Suspended ceilings below original plaster."|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"1969"|"15"|"0"|"Steel framed stairs, terrazzo treads, steel railings."|"1"|"S"|"2004"|"15"|"0"|"Enclosed wheelchair lift connecting both floors and lobby."|"1"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"|"Seams open in downstairs classroom. Repair recommended."|"1"|"COMMON"|"S"|"1969"|"10"|"0"|"In staff kitchen."|"0"|||||"0"||"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1969"|"10"|"0"|"Floor framing has plaster finish at underside and was not visible."|"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1969"|"15"|"0"|"Appears to be solid masonry wall. Exterior Cladding: Some minor cracking. Appears to be movement related rather than structural. Recommend caulking to minimize water penetration."|"1"|"MASONRY"|"S"|"1969"|"15"|"0"|"Top of chimney has been repointed. Unable to see condition of cap (other than from the ground)."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"15"|"0"|"Doors have been upgraded - estimated date."|"1"|"S"|"1969"|"15"|"0"|"Recommend balustrade on railings to limit gaps to maximum of 4"."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"15"|"0"||"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"|"Evidence of Structural Concerns with Structural Roof Deck: Deflection (not listed above) - Yes There is sag in the roof, visible from the exterior. Interior finishes showed no sign of movement."|"0"|||||"0"||"1"|"COPPER"|"S"|"1969"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1969"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||"1"|"FURNACE"||"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2004"|"4"|"9000"|"Physical damage to one condensing unit on the exterior."|"1"|"S"|"2004"|"10"|"17000"|"No mechanical ventilation. Air handling/furnace only."|"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"|"Local thermostats"|"1"|"S"|"2000"|"15"|"0"|"Year and useful life based on field observations."|"1"|"S"|"2000"|"15"|"0"|"Year and useful life based on field observations."|"0"||||"0"||"1"|"S"|"2000"|"4"|"2000"|"Additional emergency lights to illuminate egress."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"POOR"|"No mechanical ventilation is provided. Items D, E, F, G, H are not applicable for this facility."|"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"FAIR"||"28000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/21/2010 3:14:41 PM| 374|"Canastota CSD"|"25090106"|"Roberts Street School"|"0001"|"08/04/2010"|"120 ROBERTS STREET "|"CANASTOTA "|" 13032"|"ANNUAL"|"11/01/2010"|"1951"|"189974"|"2"|"7"|"2"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"1095"|"4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"1095"|"0"|"0"|||"54"|"40258"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"Low pressure at HS"|"1"|"UTIL"|"BELOW"|"S"|"1989"|"10"|"420,000"|"(3) 5kV elec. services to HS, replace MV switches in shed & courtyard xfrmrs."|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"25"|"0"||"1"|"S"|"2000"|"5"|"131,000"|"Recommend additional drainage at miscellaneous roadway and playfield areas."|"1"|"S"|"2000"|"25"|"0"|"Culverts are located in the HS playfield area."|"1"|"MUNI"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"District installed drywells in the playfield area."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"5"|"2,188,000"|"Recommend replacement of pavement north of ES extending to Peterboro St."|"1"|"CONCRETE,ASPHALT,OTHER"|"U"|"2010"|"5"|"Cost included in item 40"|"Recommend mill top course asphalt walk along bus lane and replace misc. concrete walks along front of HS."|"0"||||"0"||"1"|"U"|"2000"|"5"|"482,000"|"N"|"Recommend resurfacing existing track."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"U"|"2000"|"5"|"229,000"|"Recommend replacing concealed spline ceiling systems in HS corr's and lay-in in some HS CR's."|"1"|"S"|"2000"|"10"|"0"|"Insufficient size/ongoing maintenance (7th/8th grade wing)."|"1"|"U"|"S"|"2000"|"5"|"83,000"|"Replace doors in 9-12 corridors (not fire rated, no closers) and 1950 Loading Dock doors."|"1"|"S"|"1976"|"10"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"1"|"U"|"2000"|"5"|"175,000"|"Demo abandoned master clocks, add data outlets, replace fiber backbone, existing wireless clocks."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2000"|"5"|"134,000"|"Recommend replacing carpet at Media Center, Main Office."|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"239,000"|"Recommend replacing VAT in High School (currently in good condition)."|"1"|"COMMON"|"S"|"2000"|"10"|"0"|"Some places original (1951)."|"1"|"INSTRUCT"|"S"|"2005"|"10"|"0"|"Ongoing maintenance (sealing)."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"30"|"0"||"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"2009"|"5"|"10,000"|"Clean and repoint brick veneer. Paint EIFS & repair flashing at EIFS."|"1"|"MASONRY"|"S"|"1964"|"5"|"1,000"|"Clean and repoint brick."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"5"|"16,000"|"Recommend replacing metal doors (3 at HS gymnasium)."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"5"|"100,000"|"Recommend replacing remaining 1951 windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"0"||"U"|"2007"|"5"|"1,833,000"|"Recommend replacing all remaining ballasted roofs."|"1"|"PLASTIC"|"S"|"2007"|"5"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2000"|"5"|"44,000"|"Recommend replacing domestic water branch galv. piping at Jr. High Gym locker rooms."|"1"|"IRON"|"S"|"2000"|"40"|"0"||"1"|"NAT_GAS"|"U"|"2008"|"5"|"123,000"|"Recommend replacing hot water heaters in Boiler Room. 2009 water heater for kitchen."|"1"|"U"|"2000"|"5"|"350,000 (MS); 280,000 (HS)"|"Recommend replacing original fixtures."|"0"||"1"|"BOILERWATE"||"S"|"1989"|"15"|"0"||"1"|"U"|"2000"|"5"|"79,000"|"Gas line undersized, boilers will not operate correctly on high fire."|"1"|"U"|"2000"|"5"|"438,000"|"Auditorium air conditioning undersized."|"1"|"U"|"2000"|"5"|"2,003,000"|"Recommend replacing remaining orig. equipment: MS Kitchen & Caf; HS CR's, gym, locker rooms, cafeteria"|"1"|"U"|"2000"|"5"|"79,000"|"Middle School steam piping not replaced in 2000 requires replacement including steam traps."|"1"|"U"|"2000"|"5"|"166,000"|"Replace control dampers and operators that are not functioning. Recommend that Middle School ventilation ductwork is cleaned."|"1"|"U"|"2000"|"5"|"219,000"|"Update controls of equipment not included as part of P.C. or past projects."|"1"|"S"|"2003"|"15"|"0"|"Siemens XLS point addressable system."|"1"|"S"|"2003"|"15"|"0"|"Point addressable devices."|"1"|"S"|"2000"|"2000"|"0"|"Existing Ansul system at Kitchen Hood."|"1"|"U"|"2008"|"5"|"53,000"|"Add appropriate emergency lighting, not enough coverage, put on new generator."|"0"||||"100,000"|"District requests a new generator be installed."|"1"|"1"|"55,000"|"Provide handicapped parking spaces with proper linestriping and metal signs. Recommend providing ramp at back corridor. "|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"0"|"GOOD"|"1"|"FAIR"|"4-6 wing ventilation needs to be updated."|"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||"FULL"||"1"||"FAIR"|"District is considering reconfiguration of Jr/Sr High School to MS/HS"|"10,030,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"jbenedict@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/21/2010 3:15:48 PM| 375|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #4-MACHINE SHOP "|"0046"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"7706"|"2"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"9"|"9,10,11,12"|"0"|"0"|"1"|"9"|"0"|"0"|||"2"|"1600"|"TECHSHOP,OTHER"||"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"15"|"0"||"0"||"S"|"2003"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"5,000"|"Provide exterior lighting."|"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"15"|"10,000"|"Slurry seal is needed. "|"1"|"CONCRETE"|"S"|"1970"|"5"|"10,000"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"1"|"S"|"1971"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1971"|"10"|"0"||"1"|"S"|"S"|"1971"|"2"|"5,000"|"Replace doors at stairs - no rating or hold opens/wire glass. "|"1"|"S"|"1971"|"25"|"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"2"|"12,000"|"Replaced outdated panels, provide dust-proof covers for receptacles in tech. areas. "|"1"|"S"|"1970"|"5"|"10,000"|"Replace existing with T8 fixtures, provide shielding for lamps in tech. areas. "|"1"|"1"|"S"|"1970"|"10"|"5,000"|"Provide new PA system. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"1970"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2007"|"20"|"0"||"1"|"S"|"1970"|"5"|"100,000"|"Replace accessible ramps, loading docks and steps. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"3"|"120,000"|"Seams and flashing are deteriorating. "|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON,COPPER"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1971"|"2"|"3,000"|"Not ASME, replace with tank-less gas water heater. "|"1"|"S"|"1971"|"2"|"3,200"|"Replace faucet trim (4). "|"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"20,000"|"Replace toilet room exhaust and shop make-up air. "|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2007"|"10"|"12,500"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"0"|"0"|"1,500,000"|"Add intermediate floor, Classroom 1st and 2nd floors. Provide new elevator/upgrade toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"FAIR"||"1,623,950"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/21/2010 3:51:11 PM| 378|"North Bellmore UFSD"|"28020402"|"Park Avenue Elementary School"|"0004"|"7/30/2010"|"1599 Park Avenue"|"North Merrick"|" 11566"|"ANNUAL"|"4/01/2011"|"1957"|"44,947"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"336"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"336"|"0"|"0"|||"18"|"13500"|||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"10"|"19,000"|"Replace existing fuel oil tank monitoring & overfill alarm system"|"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"15"|"0"||"1"|"S"|"1957"|"10"|"12,000"|"School is to perform routine maintenance & ensure storm drainage system is free of all blockages & debris."|"0"||||"0"||"1"|"S"|"1957"|"7"|"0"|"District shall perform annual clean-outs of all existing catch basins & ensure proper function."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1957"|"5"|"274,000"|"Main Faculty Parking Lot is fair to poor condition & in need of replacement. "|"1"|"CONCRETE,ASPHALT"|"S"|"1957"|"5"|"0"|"Asphalt walkways to playground cracked & present tripping hazard-recommend replacement"|"1"|"S"|"2001"|"5"|"297,000"|"Playground in good condition-repave asphalt play area & improve storm drainage"|"1"|"S"|"1957"|"5"|"0"|"N"|"Routine maintenance required by District"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"1"|"S"|"1957"|"20"|"0"|"District is to monitor all non-structural cracks."|"1"|"S"|"1957"|"20"|"0"|"District is to monitor all non-structural cracks."|"1"|"S"|"1957"|"5"|"469,986"|"Majority of ceilings are concealed spline glued to non-asbestos plaster"|"0"||||"0"||"1"|"S"|"S"|"1957"|"3"|"0"|"To be addressed as part of current Bond Issue; door & hardware replace summer 2011"|"1"|"S"|"1957"|"10"|"0"|"Original risers are in good condition."|"0"||||"0"||"1"|"0"|"S"|"2000"|"5"|"60,000"|"Provide additional sub-panels & outlets to meet with District Tech needs."|"1"|"E"|"2010"|"15"|"0"||"1"|"1"|"S"|"1957"|"5"|"125,000"|"Replace existing PA/Intercom/Clock system throughout building with new"|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2010"|"15"|"25,000"|"Priority 1 floors removed-replace remaining VAT"|"1"|"INSTRUCT"|"S"|"1957"|"10"|"0"|"Painted concrete floors in good shape-regular maintenance by Owner"|"1"|"INSTRUCT"|"S"|"1957"|"10"|"0"|"All existing wood floors are in good condition."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1957"|"15"|"78,000"|"Cracks in need of masonry reconstruction. All cracked & broken bricks to be replaced & all lntels should be scraped & painted"|"1"|"MASONRY"|"E"|"2010"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"10"|"60,000"|"Exterior doors replace as part of last Bond Issue. Pair of exterior doors in need of replacement-frames should be reused."|"1"|"S"|"1957"|"10"|"15,000"|"Steps in good condition but not ADA compliant-recommend replacement of all steps/modification to make means of egress ADA accessible."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"|"Many porcelain enamel window panels damaged-these panels should be replaced on a case-by-case basis."|"CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"18"|"0"||"0"|||"2008"|"18"|"0"||"1"|"COPPER"|"S"|"1957"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1957"|"15"|"0"||"1"|"OIL"|"S"|"1996"|"5"|"0"|"Existing hot water heater is adequate-maintain service & annual inspections."|"1"|"S"|"1957"|"5"|"339,000"|"Replace existing sink base cabinets & drinking fountains w/new ADA compliant"|"1"|"CV"|"1"|"BOILERSTEA"||"U"|"1970"|"5"|"0"|"Replacement to take place summer 2011"|"1"|"S"|"1970"|"5"|"0"|"Replacement to take place summer 2011"|"1"|"S"|"1998"|"5"|"0"|"Window A/C unit"|"1"|"U"|"1957"|"1"|"0"|"All H&V units replaced as part of building wide HVAC upgrade summer 2011"|"1"|"U"|"1957"|"1"|"0"|"All piping, convectors, etc. replaced as part of building-wide HVAC upgrade summer 2011"|"1"|"U"|"1957"|"1"|"0"|"All dampers, ductwork replaced as part of building-wide HVAC upgrade summer 2011"|"1"|"U"|"1957"|"1"|"0"|"New controls will be installed as part of building-wide HVAC upgrade summer 2011"|"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"1996"|"1996"|"0"|"Existing fire supression system in Kitchen is adequate-District to maintain"|"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"0"|"0"|"New elevator, classroom sinks, toilet facilites required."|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"School is to perform routine maintenance on all ventilation equipment & filters."|"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"FAIR"||"1,805,986.00"|"U"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/21/2010 5:01:03 PM| 379|"BOCES Western Suffolk"|"58930000"|"M & O Facilities Building"|"7053"|"07/12/2010"|" 762 Deer Park Road "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"2001"|"4333"|"1"|"2"|"0"|"DISTRICT"|"OTHER"|"Maintenance and Operations"|"0"||"0"|"0"|"0"||||||"0"|"0"|"ADMIN"||"1"|"1"|"500"|"0"|"0"|"U"|"2001"|"1"|"10,000"|"Needs one additional 500 gal. tank below ground."|"1"|"MUN_UTILIT"|"E"|"2001"|"53"|"0"||"1"|"SITESEPT"|"E"|"2001"|"28"|"0"||"0"||||"0"||"1"|"UTIL,SELF"|"BELOW"|"U"|"2001"|"1"|"5,000"|"Generator needs repairs."|"0"||||"0"||"0"||||"0"||"1"|"U"|"2001"|"1"|"10,000"|"Needs additional leaching pool in parking area as originally designed."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"13"|"0"||"1"|"CONCRETE"|"E"|"2001"|"13"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2001"|"43"|"0"||"1"|"E"|"2001"|"23"|"0"||"1"|"E"|"2001"|"10"|"0"||"1"|"S"|"2001"|"3"|"0"||"0"||||"0"||"1"|"S"|"S"|"2001"|"3"|"0"||"1"|"E"|"2001"|"23"|"0"||"0"||||"0"||"1"|"1"|"E"|"2001"|"13"|"0"||"1"|"E"|"2001"|"8"|"0"||"1"|"1"|"S"|"2008"|"3"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2001"|"43"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2001"|"33"|"0"||"1"|"METAL"|"E"|"2001"|"23"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2001"|"23"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2001"|"23"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"U"|"2001"|"1"|"25,000"|"Repair leaks at exhaust fans, and over offices. Needs new grommets."|"0"|||||"0"||"1"|"COPPER"|"E"|"2001"|"23"|"0"||"1"|"IRON"|"E"|"2001"|"33"|"0"||"1"|"ELECTRIC"|"S"|"2001"|"9"|"0"||"1"|"E"|"2001"|"23"|"0"||"0"||"1"|"BOILERWATE"||"U"|"2001"|"1"|"15,000"|"Relocate heaters in Garage to clear doors."|"1"|"E"|"2001"|"13"|"0"||"1"|"S"|"2005"|"13"|"0"||"1"|"S"|"2001"|"14"|"0"||"1"|"S"|"2001"|"33"|"0"||"0"||||"0"||"1"|"S"|"2006"|"13"|"0"||"1"|"S"|"2001"|"13"|"0"||"1"|"S"|"2001"|"13"|"0"||"0"||||"0"||"1"|"S"|"2001"|"13"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"65,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979--9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/21/2010 7:51:50 PM| 380|"South Orangetown CSD"|"50030106"|"PALISADES"|"0008"|"05/26/2010"|"475 OAK TREE RD"|"PALISADES "|" 10964"|"ANNUAL"|"03/31/2011"|"1936"|"16083"|"1"|"1"|"0"|"LSD_NDE"|"INSTRUCT"||"50"|"Pre-K"|"0"|"0"|"0"|"50"|"0"|"0"|||"8"|"6100"|"ADMIN,GYM"||"0"||||||||"0"||"0"|"MUN_UTILIT"|"S"|"1936"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1936"|"25"|"0"||"1"|"S"|"1936"|"25"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1936"|"25"|"0"||"1"|"S"|"1936"|"25"|"0"||"0"||||"0"||"1"|"S"|"1936"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2009"|"1"|"49044"|"Full depth repairs and overlay are required for remaining pavement not replaced in 2009."|"1"|"ASPHALT"|"S"|"2009"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1936"|"20"|"6538"|"There is a significant amount of water entering the basement as evidenced dby the water stains and makeshift basement drain to channel water from the pipe chase to the sump pump. The boiler is set on a concrete pad."|"1"|"S"|"1936"|"20"|"0"||"1"|"S"|"1936"|"20"|"0"||"1"|"S"|"1993"|"3"|"14940"|"Replace damaged ceiling tiles and replace old twelve inch system with new system."|"1"|"S"|"1936"|"20"|"0"||"1"|"S"|"S"|"1936"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1936"|"5"|"93016"|"Upgrades to distribution and branch wiring as needed to facilitate lighting replacement throughout."|"1"|"S"|"1936"|"12"|"0"||"1"|"1"|"S"|"1995"|"12"|"0"||"0"|"S"|||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"15"|"0"||"1"|"COMMON"|"S"|"1964"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1936"|"15"|"0"|"Replace damaged section of gymnasium wood floor."|"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1936"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"1936"|"20"|"0"|"Exterior water intrusion is discussed foundations."|"1"|"MASONRY"|"S"|"1936"|"20"|"0"||"1"|"MASONRY"|"S"|"1936"|"20"|"0"||"S"|"S"|"1"|"1"|"1996"|"20"|"0"||"1"|"S"|"1936"|"20"|"0"||"0"|||||"0"||"1"|"VINYL,WOOD"|"S"|"Y"|"1996"|"15"|"0"||"METONMET,WOODONWOOD"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"1988"|"0"|"199995"|"The pitched roofing system has completely failed. It is currently covered with a tarp to prevent any further water intrusion and roof deck deterioration. There is evidence of current and past roof leaks on the flat roof."|"0"|||||"0"||"1"|"COPPER"|"S"|"1936"|"12"|"0"||"1"|"IRON"|"S"|"1936"|"12"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"14"|"0"||"1"|"S"|"1985"|"12"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2010"|"35"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"U"|"1991"|"1"|"33300"|"Replace steam distribution system."|"0"||||"0"||"1"|"S"|"1990"|"12"|"0"||"1"|"S"|"1936"|"12"|"12500"||"1"|"S"|"1936"|"12"|"12500"||"1"|"S"|"1966"|"1966"|"0"||"1"|"S"|"1936"|"12"|"5000"||"0"||||"0"||"1"|"1"|"6433"|"Signage and striping required for ADA parking stalls, installation of an interior ADA ramp to access original and building additions."|"FAIR"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"0"|||"1"|"1"||"GOOD"||"379566"|"U"|"1"|"EMG"|"222 Schilling Circle, Suite 275, Hunt Valley, MD 21031"|"800-733-0660"|"klcarneval@emgcorp.com"|"Bill Champion"|"087867"|"I ACCEPT"|12/21/2010 7:59:24 PM| 384|"Southwestern CSD At Jamestown"|"06020106"|"High School"|"0005"|"10/20/2011"|"600 Hunt Road"|"Jamestown"|" 14701"|"ANNUAL"|"07/01/2011"|"1954"|"153885"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"453"|"9,10,11,12"|"0"|"1"|"1"|"453"|"0"|"0"|||"34"|"25710"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,SCIENCELAB,SPECED,TECHSHOP,OTHER"|"Distance Learning"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"40"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1954"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1995"|"15"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"15"|"0"|"Additional parking required per Code. Asphalt shoulder repairs recommended."|"0"||||"0"||"1"|"S"|"2009"|"10"|"0"|"Y"|"Guardrails recommended at protable bleachers"|"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2001"|"30"|"0"|"Water in boiler room, investigation required"|"1"|"S"|"2002"|"30"|"0"||"1"|"E"|"2009"|"29"|"0"||"1"|"E"|"2002"|"12"|"0"||"1"|"E"|"2009"|"19"|"0"||"1"|"E"|"E"|"2009"|"15"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"S"|"2010"|"15"|"0"|"Maintenance Contract"|"1"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"|"Replace broken and missing lenses in locker rooms and wood shop"|"1"|"1"|"S"|"2002"|"15"|"0"|"Repair/replace non-functioning clocks"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"12"|"0"|"Computer lab replaced 2008, other areas vary"|"1"|"INSTRUCT"|"S"|"2000"|"5"|"0"|"Replace VAT in classrooms - end of service life"|"1"|"COMMON"|"E"|"1954"|"30"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"27"|"0"|"Gym floor re-built 2002"|"SLABGRADE,OTHER"|"Cast-in-place concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2001"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"E"|"2009"|"30"|"0"|"Efflorescence observed at boys/girls showers repointed 2007"|"1"|"MASONRY"|"E"|"2009"|"30"|"0"|"Repointed 2009"|"1"|"MASONRY"|"E"|"2009"|"30"|"0"|"Repointed 2009"|"S"|"E"|"0"|"1"|"2009"|"10"|"0"||"1"|"S"|"2009"|"3"|"0"|"Repair stairs at loading dock"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1998"|"8"|"0"|"Add "Rescue Window" label to roller shades"|"METONMET,OTHER"|"SINGLEPLY,BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"|"Splits and cracks at BUR areas, water below roofing membrane"|"S"|"2007"|"22"|"0"|"Useful life varies with roofing materials and areas"|"1"|"PLASTIC"|"S"|"2007"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2008"|"10"|"0"|"Clean old drain lines"|"1"|"NAT_GAS"|"S"|"2002"|"7"|"0"|"Correct controls"|"1"|"E"|"2008"|"18"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2009"|"12"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"S"|"2002"|"10"|"0"|"Leaks in glycol piping groove couplings"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"|"Replace (1) 3-way pneumatic valve with DDC"|"1"|"S"|"2002"|"10"|"0"|"Relocate pull station at end of corridor 208"|"1"|"S"|"2002"|"10"|"0"|"Install heat detector in Main Office kitchenette area"|"1"|"S"|"2002"|"2002"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"|"Re-occurring issue with generator clock wiring"|"1"|"1"||"Add signage identifying ADA toilet rooms and general room identification"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"0.00"|"E"|"1"|"Trautman Associates"|"470 Franklin Street, Buffalo, NY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M. Gehring"|"019087"|"I ACCEPT"|12/22/2010 9:35:31 AM| 386|"BOCES Albany-Schoh-Schen"|"01900000"|"Maritime Center"|"8026"|"7/20/2010"|"901 Maritime Drive"|"Alplaus"|" 12008"|"ANNUAL"|"10/1/2011"|"2000"|"10000"|"1"|"1"|"0"|"LSD_DIST"|"INSTRUCT"||"50"|"4,5,6,7"|"0"|"1"|"0"|"50"|"0"|"0"|||"2"|"1800"|"ADMIN,KITCHEN,TECHSHOP"||"0"||||||||"0"||"1"|"WELL"|"S"|"2000"|"15"|"0"|"Filtration/chlorination system to treat water."|"1"|"MUN_UTILIT"|"S"|"2009"|"15"|"0"|"Building has been connected to the Alplaus sewer system."|"1"|"S"|"2000"|"15"|"0"|"(2) 1,000 gal LP Tanks"|"1"|"UTIL"|"BELOW"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"|"Surface drainage"|"0"||||"0"||"1"|"S"|"2010"|"15"|"0"|"ADS culverts below drive"|"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"15"|"0"||"1"|"CONCRETE"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"|"Gypsum board on metal framing. Need constant repair due to abuse."|"1"|"S"|"2000"|"15"|"0"|"Exposed in shops"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"All fixtures are T12 lamps"|"1"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"15"|"0"||"STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"15"|"0"|"Steel framing, metal siding with some EIFS"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"15"|"0"||"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"15"|"0"|"EPDM and Metal Roofing"|"0"|||||"0"||"1"|"COPPER,PVC"|"S"|"2000"|"15"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"2000"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2005"|"10"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"CV"|"1"|"FURNACE,OTHER"|"Rooftop units"|"S"|"2000"|"4"|"85000"|"Rooftop units - limited life span"|"1"|"S"|"2000"|"15"|"0"|"Propane"|"1"|"S"|"2000"|"4"|"0"|"Rooftop units - replacement recommended (see Heat Generating Systems)"|"1"|"S"|"2000"|"4"|"0"|"Rooftop units - replacement recommended (see Heat Generating Systems)"|"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"Stand alone thermostats"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"255000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/22/2010 9:49:27 AM| 388|"Harrison CSD"|"66050106"|"Parsons Elementary School"|"0006"|"10/06/2010"|"200 Halstead Avenue"|"Harrison"|" 10528"|"ANNUAL"|"03/01/2011"|"1898"|"73149"|"4"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"460"|"K,1,2,3,4,5"|"0"|"0"|"1"|"460"|"0"|"0"|||"24"|"14804"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED"||"1"|"1"|"5000"|"0"|"0"|"S"|"1980"|"5"|"125000"|"Budget for 10000 gallon tank"|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"75000"|"Budget to provide fire hydrants "|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"0"||"1"|"S"|"1996"|"36"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"35"|"30000"|"Budget to provide additional light fidxtures"|"1"|"S"|"1996"|"5"|"50000"|"Budget to evaluate and reconstruct as required"|"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"5"|"75000"|"Budget to provide additional parking "|"1"|"CONCRETE,ASPHALT"|"S"|"1996"|"5"|"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"2008"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1898"|"15"|"0"||"1"|"S"|"1898"|"15"|"22000"|"Budget to fire stop and repair select walls"|"1"|"S"|"1898"|"15"|"13000"|"Budget for display cases and partition repair"|"1"|"S"|"2009"|"15"|"340000"|"Budget to repair or replace ceiling in select areas"|"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"S"|"1996"|"15"|"369500"|"Budget to repair or upgrade interior doors"|"1"|"S"|"1898"|"15"|"66000"|"Budget to replace or provide rails and repair stair wells as needed"|"0"||||"0"||"1"|"1"|"S"|"1996"|"5"|"313000"|"Budget to provide hand dryers and replace or upgrade panels"|"1"|"S"|"1994"|"8"|"294750"|"Budget to repair upgrade and provide select light fixtures"|"1"|"1"|"S"|"1996"|"10"|"181000"|"Budget to replace or upgrade security and PA systems"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"5"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"5"|"28100"|"Budget to replace VAT with VCT"|"1"|"COMMON"|"S"|"1996"|"5"|"1200"|"Budget to repair tile flooring"|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"5"|"0"||"SLABGRADE,PRECAST,OTHER"|"Re inforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1898"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1996"|"15"|"265000"|"Budget for pointing and for repair of fence"|"1"|"MASONRY"|"S"|"1996"|"15"|"0"||"1"|"MASONRY"|"S"|"1996"|"15"|"0"||"S"|"S"|"0"|"1"|"1996"|"0"|"160000"|"Budget to replace remaining aluminum doors"|"1"|"S"|"1898"|"15"|"15000"|"Budget to repaoir stairwell down to field "|"1"|"S"|"1"|"1996"|"15"|"0"||"1"|"ALUMINUM"|"S"|"Y"|"1982"|"0"|"623650"|"Budget for full window replacement"|"WOODONWOOD"|"SINGLEPLY,ASPHALT,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"E"|"1998"|"5"|"135000"|"Budget for repairs on entire roof"|"1"|"GLASS"|"S"|"1998"|"5"|"0"||"1"|"LEAD"|"S"|"1996"|"35"|"12500"|"Budget to provide additional faucets"|"1"|"IRON"|"S"|"1928"|"0"|"36000"|"Budget to repair or replace select drains"|"1"|"NAT_GAS"|"E"|"2002"|"5"|"0"||"1"|"S"|"1998"|"37"|"80000"|"Budget to remove and replace select fixtures"|"0"||"1"|"BOILERSTEA"||"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"2002"|"2"|"0"||"0"|"S"|"1928"|"0"|"1415000"|"Budget to provide unit vents and exhausts for fresh air in selct areas"|"1"|"S"|"1928"|"2"|"120000"|"Budget to upgrade and reinsulate piping"|"1"|"S"|"1928"|"2"|"50000"|"Budget to repair ductwork in select areas"|"1"|"S"|"1996"|"5"|"270000"|"Budget to replace controls and expand AHUs"|"1"|"S"|"1996"|"10"|"21500"|"Budget to upgrade and repair fire alarm"|"0"|"S"|"1996"|"10"|"24000"|"Budget to provide additional devices"|"0"||||"0"||"1"|"S"|"1994"|"8"|"65000"|"Budget to provide and replace lighting units"|"0"||||"0"||"1"|"0"|"300"|"Budget to provide grab bar in select area"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"1"|"0"||"WARMING"||"1"||"FAIR"|"Proposed Bond Project $15.2 million"|"5401500"|"S"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Richard Searles RA"|"021614"|"I accept"|12/22/2010 10:10:52 AM| 389|"Harpursville CSD"|"03050104"|"Elementary School"|"0006"|"10/20/2010"|"54 Main St."|"Harpursville"|" 13787"|"ANNUAL"|"11/01/2011"|"1965"|"85,740"|"2"|"3"|"3"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"538"|"Pre-K,K,1,2,3,4,5,6"|"0"|"1"|"0"|"538"|"0"|"0"|||"38"|"30,826"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1998"|"10"|"10,000"|"Replace leak detection system"|"1"|"WELL"|"S"|"1996"|"12"|"0"||"1"|"SITESEPT"|"S"|"1996"|"12"|"100,000"|"Add emergency power to Sanitary Pumps"|"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"2009"|"15"|"0"|"Replaced only one (1) transformer on pole."|"1"|"S"|"1965"|"10"|"0"||"1"|"S"|"1965"|"10"|"0"||"1"|"S"|"1965"|"10"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1965"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1996"|"2"|"200,000"|"Significant areas of pavement failure"|"1"|"CONCRETE,ASPHALT"|"U"|"1996"|"10"|"120,000"|"Areas of sidewalk and curb degradation."|"1"|"U"|"1996"|"5"|"225,000"|"Some equipment is constructed of wood. Has problems with bee infestation, and does not meet code requirements for fall protection or accessibility."|"1"|"S"|"1996"|"7"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"25"|"0"||"1"|"S"|"1965"|"25"|"0"||"1"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"10"|"0"|"Portions of the existing ceilings should be replaced due to asbestos abatement."|"1"|"U"|"1996"|"10"|"16,000"|"Portions of the existing lockers are corroding sooner than expected. Clean and refinish all units."|"1"|"S"|"S"|"1996"|"10"|"94,000"|"Replace all non-ADA hardware and select interior doors."|"1"|"U"|"1965"|"2"|"2,500"|"Several precast terrazzo treads are damaged and in need of replacement."|"1"|"S"|"1996"|"15"|"0"||"1"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"5"|"150,000"|"Replace HID fixtures in Gymnasium, replace original 1x4 egg crate fixtures in 1967 portion of building."|"1"|"0"|"U"|"1965"|"5"|"320,000"|"Replace building wide paging, intercom, and telephone system. Install Gymnasium sound system."|"0"||||"0"||"1"|"INSTRUCT"|"U"|"1996"|"5"|"40,000"|"Replace select areas of worn carpet and replace carpet in areas where asbestos containing resilient tile exists below."|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"15"|"200,000"|"Remove asbestos containing resilient tile and replace."|"1"|"COMMON"|"S"|"1996"|"20"|"40,000"|"Replace quarry tile floor in kitchen as part of larger renovation scope."|"1"|"INSTRUCT"|"S"|"1996"|"20"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"1"|"0"|"S"|"1996"|"25"|"20,000"|"Repair plank topping in one room where excessive settling has occurred. Replace finish."|"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"0"|"Minimal paint failure"|"S"|"1996"|"20"|"32,000"|"Paint select areas of the exterior, including lintels, replace caulk selectively."|"1"|"METAL"|"S"|"1996"|"10"|"35,000"|"Replace base of stack. Raise stack height to deter fumes into building."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1965"|"5"|"60,000"|"Replace main entry doors with ADA compliant units. Replace other exterior doors selectively."|"1"|"S"|"1996"|"7"|"40,000"|"Kitchen loading dock requires reconstruction."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1996"|"10"|"60,000"|"District reports some roof leaks. Rebuild penetrations and seams to extend life."|"1"|"GLASS"|"S"|"1996"|"15"|"0"||"1"|"COPPER"|"S"|"1996"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1996"|"20"|"15,000"|"Replace kitchen floor drain piping."|"1"|"OIL"|"S"|"2000"|"10"|"0"||"1"|"S"|"1996"|"5"|"60,000"|"Replace all dated fixtures, faucets, and flush valves. Replace art room clay trap."|"1"|"CV"|"1"|"BOILERWATE"||"NF"|"1996"|"15"|"150,000"|"Replace one (1) non-functional boiler"|"1"|"S"|"1996"|"15"|"35,000"|"Replace fuel oil lines from tank to pumps. Replace pumps."|"1"|"S"|"1996"|"5"|"50,000"|"Replace four (4) PTAC units including Main Office and add A/C to Special Education Room."|"1"|"S"|"1996"|"10"|"185,000"|"Replace twelve (12) exhaust fans. Add ventilation to Room #176, Room 109A, Room 201 (near elevator), and Nurse's suite."|"1"|"S"|"1996"|"10"|"10,000"|"Repair Boiler Room pipe insulation."|"1"|"S"|"1996"|"20"|"25,000"|"Clean and sanitize Gymnasium and Cafeteria ductwork."|"1"|"S"|"1996"|"10"|"15,000"|"Add site lights to DDC. Replace air compressor filter/dryer."|"1"|"U"|"1996"|"2"|"74,000"|"Replace entire fire alarm system and bring up to code. Add notification devices in classrooms, toilet rooms, and corridors."|"1"|"U"|"1996"|"2"|"74,000"|"Add initiation devices in storage areas, add additional in corridors."|"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1996"|"5"|"105,000"|"Replace and add exits and emergency lighting. Revise various existing corridor lighting to be on emergency. Add emergency lites at exit discharges."|"1"|"S"|"2004"|"10"|"100,000"|"Currently fed from H.S. generator with one ATS. Relocate H.S. generator and add additional ATS to seperate life safety and equipment loads."|"1"|"1"|"24,000"|"Modifications to main entrance for ADA."|"GOOD"||"GOOD"||"0"|"1"|"FAIR"|"Acoustics in the Cafeteria should be addressed as part of a renovation."|"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"1"|"CLASSROOMS"|"One room - leak"|"0"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"||"GOOD"|"The kitchen is undersized."|"7,500,000"|"U"|"0"|"Ashley McGraw Architects, P.C."|"500 South Salina Street, Syracuse, NY 13202"|"315-425-1811"|"deuel@ashleymcgraw.com"|"Nicholas Signorelli"|"024017"|"I ACCEPT"|12/22/2010 10:15:29 AM| 391|"Southwestern CSD At Jamestown"|"06020106"|"Bus Storage Garage"|"4002"|"10/20/2010"|"191 Bently Avenue"|"Jamestown"|"14701"|"ANNUAL"|"07/01/2011"|"1963"|"15174"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus garage and maintenance"|"0"|||"0"|"1"||||||"0"|"0"|"NONE"||"1"|"1"|"1000"|"0"|"0"|"S"|"2000"|"10"|"0"|"Diesel fuel"|"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1967"|"10"|"0"||"1"|"U"|"1967"|"5"|"90000"|"Water back-up occurs during heavy rainfall, investigation required"|"1"|"S"|"1967"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"OTHER"|"Unable to loacte"|"0"|"S"|"1967"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"1967"|"10"|"0"|"Asphalt pavement repairs needed"|"0"|||||"0"||"1"|"U"|"1967"|"0"|"8400"|"Swingset does not meet safety clearance requirments"|"1"|"U"|"2000"|"10"|"48000"|"N"|"Player protective fencing needed, bleacher guardrails needed, various fencing repairs needed"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"20"|"0"||"1"|"S"|"1967"|"20"|"0"||"1"|"E"|"2002"|"20"|"0"||"1"|"E"|"2002"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"1"|"E"|"E"|"2002"|"10"|"0"|"Replace driver's room hardware"|"1"|"E"|"1967"|"20"|"0"|"Metal ship ladder to storage mezzanine"|"0"||||"0"||"1"|"1"|"S"|"1967"|"20"|"0"|"Change garage receptacles to GFI"|"1"|"U"|"2002"|"5"|"24000"||"1"|"1"|"S"|"2002"|"5"|"36000"|"2-way system to be changed to narrow band regulations"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2007"|"10"|"0"||"1"|"COMMON"|"E"|"1967"|"25"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1967"|"20"|"0"|"Remove and replace backer rod and sealant in all control joints"|"0"|||||"0"||"1"|"MASONRY"|"S"|"1967"|"20"|"0"||"E"|"E"|"0"|"1"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"1967"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"10"|"0"|"Repair concrete tees's at 1963 building"|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"17"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"4"|"24000"|"Water back-up into office and drivers area"|"1"|"NAT_GAS"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2007"|"17"|"0"||"1"|"S"|"1967"|"5"|"12000"|"Replace two original gas unit heaters"|"0"||||"0"||"1"|"S"|"2007"|"12"|"0"|"Recommend nitrogen dioxide sensors to garage ventilation system"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2007"|"12"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"1993"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"25"|"0"||"0"||||"0"|"Recommend back-up power for bus 2-way radios and phone system"|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"242400"|"S"|"1"|"Trautman Associates"|"470 Franklin Street, Buffalo, NY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M. Gehring"|"019087"|"I ACCEPT"|12/22/2010 10:28:12 AM| 392|"Harrison CSD"|"66050106"|"Purchase Elementary School"|"0001"|"09/21/2010"|"2995 Purchase Street"|"Harrison"|" 10577-2216"|"ANNUAL"|"03/01/2011"|"1906"|"60560"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"413"|"K,1,2,3,4,5"|"0"|"0"|"0"|"413"|"0"|"0"|||"26"|"22544"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB"||"1"|"1"|"4750"|"0"|"0"|"S"|"1986"|"16"|"125000"|"Replace oil tank with larger size"|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"75,000"|"Provide fire hydrants on site."|"1"|"MUN_UTILIT"|"S"|"1996"|"35"|"25000"|"Repair or replace sewer ejector pump"|"1"|"S"|"1986"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"35"|"81000"|"Upgrade site lighting, lightning protection systems, and repairs"|"1"|"S"|"1989"|"29"|"225000"|"Provide additional site drainage"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"MUNI,ONSITE"||"1"|"S"|||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"5"|"75000"|"Reconfigure and refurbish existing parking areas"|"1"|"CONCRETE,ASPHALT"|"S"|"2007"|"5"|"10000"|"Replace sections of deteriorating sidewalk"|"1"|"S"|"1999"|"5"|"8000"|"Provide general maintenance on playground structures"|"1"|"S"|"1996"|"15"|"250000"|"N"|"Rehabilitate play fields and provide additional drainage."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1906"|"15"|"0"||"1"|"S"|"1906"|"15"|"47500"|"Repair cracks, provide fire stopping and appropriape fire separation through walls"|"0"|"S"|"1906"|"15"|"30000"|"Repair surface cracks and insulate wall above ceiling at gym"|"1"|"S"|"1996"|"15"|"8000"|"Firestop openings in storage and mech room ceilings. Replace select ceiling tiles."|"0"||||"0"||"1"|"S"|"S"|"1996"|"15"|"249500"|"Repair or replace select doors, provide ADA hardware, upgrade door closers and provide automatic power assisted ADA doors at three locations. Address dead end corridor at Library."|"1"|"S"|"1996"|"15"|"29250"|"Upgrade railings"|"1"|"S"|"1996"|"15"|"0"||"1"|"1"|"S"|"1996"|"25"|"243000"|"Balance electric panels and provide new panels in select locations. "|"1"|"S"|"1994"|"8"|"8000"|"Increase attic lighting, install additional lights at south lobby."|"1"|"1"|"S"|"1996"|"0"|"50000"|"Upgrade speakers and security systems"|"0"|"S"|||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"5"|"184100"|"Replace VAT flooring, refinish wood floors, Replace cafeteria flooring."|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"5"|"72500"|"Provide new wood gym floor"|"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1906"|"15"|"4000"|"Repair large crack at second floor expansion joint"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1906"|"15"|"15100"|"Exterior repairs and maintenance"|"1"|"MASONRY"|"S"|"1906"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"5"|"0"||"1"|"S"|"1996"|"15"|"11500"|"Provide 2nd egress from boiler room. Provide 42" handrail at entry platform."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"0"|"251500"|"Replace windows in original building. Rescue windows difficult to open. Window repairs."|"METONMET,WOODONWOOD,OTHER"|"SINGLEPLY,ASPHALT,FORMMETAL,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"5"|"170000"|"Repairs to dormers, drain pipes, soffit and fascia."|"1"|"PLASTIC"|"S"|"1996"|"5"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1996"|"35"|"308500"|"Replace galvanized piping. Provide additional hose bib connections"|"1"|"IRON"|"S"|"1996"|"35"|"5000"|"Repair roof vents"|"1"|"NAT_GAS"|"E"|"2004"|"4"|"0"||"1"|"S"|"1996"|"35"|"50000"|"Replace select plumbing fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1986"|"15"|"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"35"|"337000"|"Upgrade and provide air systems for select ares."|"1"|"S"|"1996"|"35"|"0"||"1"|"S"|"1996"|"35"|"0"||"1"|"S"|"1996"|"5"|"180000"|"Budget for DDC controls"|"1"|"S"|"1999"|"14"|"32900"|"Extend system"|"1"|"S"|"1999"|"14"|"12500"|"Additional detectors needed."|"1"|"S"|"1996"|"1996"|"15"|"Upgrades"|"1"|"S"|"1994"|"4"|"14000"|"Upgrades and repairs"|"0"||||"125000"|"Budget for new 75kva generator"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"POOR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"1"|"0"||"WARMING"||"1"||"FAIR"|"Proposed Bond Project $14.3 million"|"3358850"|"S"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Richard Searles RA"|"021614"|"I accept"|12/22/2010 10:30:13 AM| 395|"Southwestern CSD At Jamestown"|"06020106"|"Concession Stand"|"7007"|"10/20/2010"|"600 Hunt Road"|"Jamestown"|"14701"|"ANNUAL"|"07/01/2011"|"2007"|"798"|"1"|"0"|"0"|"DISTRICT"|"OTHER,OTHER_ORG"|"Sporting events"|"0"|||"0"|"1"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2007"|"30"|"0"|"Wood skid "foundation" resting on asphalt"|"0"||||"0"||"1"|"S"|"2007"|"30"|"0"||"1"|"E"|"2007"|"30"|"0"|"Open wood truss"|"0"||||"0"||"1"|"S"|"S"|"2007"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"25"|"0"|"Recommend changing all outlets to GFI"|"1"|"S"|"2007"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2007"|"10"|"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2007"|"30"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"2007"|"10"|"0"|"Push up door for service window"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"27"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"0"|"500"|"Lower service counter"|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"FAIR"|"No ventilation"|"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"500"|"E"|"1"|"Trautman Associates"|"470 Franklin Street, Buffalo, NY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M. Gehring"|"019087"|"I ACCEPT"|12/22/2010 11:08:34 AM| 396|"Yorkshire-Pioneer CSD"|"04350106"|"ARCADE ELEMENTARY"|"0010"|"11/10/2010"|"9 CHURCH STREET"|"ARCADE"|" 14009"|"ANNUAL"|"07/01/2011"|"1929"|"139,154"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"564"|"K,1,2,3,4"|"0"|"1"|"1"|"564"|"0"|"0"|||"44"|"36,504"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1929"|"5"|"75,000"|"REPLACE WATER SERVICE."|"1"|"MUN_UTILIT"|"S"|"1929"|"15"|"0"||"1"|"S"|"1990"|"5"|"25,000"|"UPGRADE GAS SERVICE WITH 2010 CAPITAL PROJECT."|"1"|"UTIL"|"BELOW"|"U"|"1990"|"1"|"375,000"|"REPLACEMENT OF ELECTRICAL SERVICE IN CURRENT PROJECT. INSTALL PARKING AREA SITE LIGHTING. REPLACE AERIAL WIRING AT PLAYGROUND."|"0"||||"0"||"1"|"S"|"1929"|"15"|"0"||"1"|"U"|"2009"|"5"|"40,000"|"REPLACE 4 CATCH BASINS"|"0"||||"0"||"1"|"SURFACEH2O"|"DRAIN TO CREEK"|"1"|"S"|"1989"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1996"|"2"|"370,000"|"REPLACE ALL PAVEMENT."|"1"|"CONCRETE"|"U"|"1996"|"2"|"90,000"|"REPLACE ALL WALKWAYS."|"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"U"|"2008"|"2"|"235,000"|"REPLACE CEILINGS AT MISCELLANEOUS CLASSROOMS AND CORRIDORS."|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"S"|"1990"|"15"|"0"||"1"|"U"|"1953"|"1"|"90,000"|"REPLACE STAIR TREADS/RISERS AND PAINT RAILS."|"1"|"S"|"1996"|"15"|"0"||"1"|"0"|"S"|"1990"|"5"|"92,000"|"INSTALL ADDITIONAL GENERAL PURPOSE RECEPTICALES IN ORIGINAL CLASSROOMS."|"1"|"S"|"1999"|"5"|"565,000"|"REPLACE ALL INTERIOR T12 FLUORESCENT AND HID LUMINAIRES. REPLACE AUD DIMMING SYSTEM."|"1"|"1"|"S"|"1999"|"5"|"470,000"|"REPLACE CLOCK, PUBLIC ANNOUNCEMENT, SUB-SOUND AND CAT-V SYSTEMS. INSTALL AREA OF RESCUE SYSTEM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1990"|"3"|"400,000"|"REPLACE CARPET WITH VCT IN MISCELLANEOUS CLASSROOMS."|"1"|"INSTRUCT,COMMON"|"S"|"2008"|"10"|"0"||"1"|"COMMON"|"S"|"1990"|"15"|"0"||"1"|"COMMON"|"U"|"1939"|"2"|"15,000"|"REFINISH GYMNASIUM AND AUDITORIUM STAGE FLOORS."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"30"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"1939"|"20"|"0"||"S"|"S"|"0"|"0"|"1999"|"1"|"45,000"|"REPLACE SECURITY DEVICES AND CONTROL."|"1"|"U"|"1990"|"1"|"34,000"|"3 EXTERIOR STAIRS BEING REPLACES IN 2011."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1990"|"2"|"730,000"|"REPLACE EXISTING WINDOWS."|"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"|"ADD 3 ROOF DRAINS"|"U"|"1996"|"1"|"25,000"|"ADD 3 ADDITIONAL ROOF DRAINS"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1990"|"5"|"50,000"|"UPGRADE HOT WATER RECIRCULATION SYSTEM. REPLACE VALVES, ADD PRV."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"1"|"40,000"|"REPLACE DETERIORATED PIPING."|"1"|"NAT_GAS"|"U"|"1990"|"5"|"50,000"|"REPLACE WATER HEATER."|"1"|"U"|"2007"|"5"|"100,000"|"REPLACE FIXTURES."|"0"||"1"|"BOILERWATE,OTHER"|"ELECTRIC BOILER"|"E"|"2008"|"15"|"0"||"1"|"S"|"1929"|"15"|"0"|"MUNICIPAL ELECTRIC SYSTEM"|"1"|"S"|"2008"|"5"|"1,610,000"|"REPLACE ORIGINAL HEAT PUMPS, CAFETERIA AIR CONDITIONING UNIT AND COOLING TOWER."|"1"|"S"|"2008"|"5"|"160,000"|"REPLACE ORIGINAL EXHAUST FANS AND GYMNASIUM AIR HANDLING UNITS."|"1"|"S"|"2008"|"5"|"80,000"|"REPLACE ORIGINAL PUMPS, MISCELLANEOUS PIPING AND RADIATORS."|"1"|"S"|"2008"|"5"|"25,000"|"INTERNAL DUCT CLEANING OF AUDITORIUM SYSTEMS."|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1990"|"1"|"110,000"|"REPLACE SYSTEM WITH ADDRESSABLE TYPE."|"1"|"U"|"1990"|"0"|"35,000"|"REPLACE SMOKE DETECTORS, HEADS ONLY."|"0"||||"0"||"1"|"U"|"1990"|"0"|"70,000"|"INSTALL EXTERIOR EMERGENCY LIGHTING AND UPGRADE INTERIOR EMERGENCY LIGHTING BEING INSTALLED. INSTALL LED EXIT SIGNAGE."|"1"|"U"|"1990"|"0"|"60,000"|"SEGREGATE STANBY AND EMERGENCY CIRCUITS. ADD NEW OUTDOOR GENERATOR (CURRENTLY BID)."|"1"|"1"|"18,000"|"PROVIDING HANDICAP ACCESSIBILITY AT 2ND FLOOR TOILETS ROOMS AT 1953 BUILDING."|"FAIR"||"FAIR"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"1"||"FAIR"||"6,000,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES ARCHITECTECTS"|"5757 MAIN STREET, WILLIAMSVILLE, NEW YORK 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/22/2010 11:08:59 AM| 398|"North Bellmore UFSD"|"28020402"|"Saw Mill Road Elementary School"|"0005"|"08/03/2010"|"2801 Saw Mill Road"|"North Bellmore"|" 11710"|"ANNUAL"|"04/01/2011"|"1953"|"65,650"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"494"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"494"|"0"|"0"|||"31"|"23250"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1987"|"10"|"19,000"|"Replace existing fuel oil tank monitoring & overfill alarm station."|"1"|"MUN_UTILIT"|"S"|"1959"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1959"|"10"|"0"||"1"|"S"|"1959"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2003"|"15"|"0"||"1"|"S"|"1959"|"10"|"0"|"District to perform routine maintenance & ensure storm drainage system is free of all blockages."|"0"||||"0"||"1"|"S"|"1959"|"10"|"0"|"District shall perform annual cleanups of all existing catch basins & ensure proper function."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1959"|"7"|"208,000"|"Recommend concrete sidewalk & curbifng along main entrance be replaced due to cracking"|"1"|"CONCRETE,ASPHALT"|"S"|"1959"|"5"|"0"||"1"|"S"|"2001"|"15"|"85,200"|"Recommend installation of new 1" topcoat at play areas - playground in good condition & ADA accessible."|"1"|"S"|"1959"|"5"|"0"|"N"|"Routine maintenance to be performed by District."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1959"|"25"|"0"||"1"|"S"|"1959"|"10"|"30,000"|"Boiler Room in need of fire rated plaster ceiling assembly repair-School to monitor various non-structural cracks"|"1"|"S"|"1959"|"10"|"14,000"|"Several masonry cracks were noted throughout building probably due to settlement & should be repaired."|"1"|"S"|"1959"|"5"|"540,080"|"Ceilings throughout building are concealed spline & are in need of repair."|"0"||||"0"||"1"|"S"|"S"|"1959"|"3"|"0"|"Interior doors & hardware replacement to take place summer 2011"|"1"|"S"|"1959"|"25"|"0"|"Original risers are in good condition."|"0"||||"0"||"1"|"0"|"S"|"2000"|"5"|"75,000"|"Provide additional sub-panels & outlets to meet with District Tech needs"|"1"|"E"|"2010"|"20"|"0"||"1"|"1"|"S"|"1959"|"5"|"137,000"|"Replace existing PA/Intercom/Clock System throughout the building with new "|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"12"|"0"|"Carpet in Main Office is in good condition."|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"15"|"280,400"|"Recommend District formulate a long term plan for replacing existing VAT on priority basis-to be removed summer 2011"|"1"|"INSTRUCT"|"S"|"1953"|"15"|"0"|"Painted concrete floors in various conditions."|"1"|"INSTRUCT"|"S"|"1959"|"10"|"0"|"Existing wood floor in good shape"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1959"|"25"|"0"||"MASONRY"|"1"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1959"|"25"|"57,000"|"Repointing is required around existing chimney & several lintels over window should be scraped & painted."|"1"|"MASONRY"|"S"|"1959"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"10"|"8,000"|"Service entrance doors adjacent to Boiler Room should be replaced-all exterior doors were replaced during past Bond Issue"|"1"|"S"|"1959"|"10"|"50,000"|"Steps in good condition but not ADA compliant. Recommend replacement to make means of egress ADA accessible."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1959"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1959"|"15"|"0"||"1"|"OIL"|"S"|"2000"|"7"|"0"||"1"|"S"|"1959"|"5"|"422,000"|"Toilets converted to handicapped accessible"|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1959"|"2"|"0"|"Part of current Bond Issue-replaced summer 2011"|"1"|"S"|"1959"|"2"|"0"|"To be replaced 2011"|"1"|"S"|"2005"|"8"|"0"|"Window A/C units."|"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2010"|"10"|"0"|"All steam traps have been refurbished."|"1"|"S"|"2010"|"5"|"0"||"1"|"S"|"1994"|"5"|"101,000"|"Pneumatic controls on all equipment are in need of rehabilitation"|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"1996"|"1996"|"0"|"Existing fire suppression system in Kitchen-Owner to maintain"|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"1"|"0"|"0"||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"School is to perform routine maintenance on all ventilation equipment & filters."|"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"FAIR"||"2,576,600.00"|"S"|"0"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/22/2010 11:16:47 AM| 399|"Lockport City SD"|"40040001"|"Administration"|"1014"|"06/23/2010"|"130 BEATTIE AVENUE "|"LOCKPORT "|" 14094"|"ANNUAL"|"12/01/2010"|"1969"|"12900"|"1"|"1"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"|"2" service with water meter and shut-off valves. No backflow prevention device installed."|"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"|"combination sanitary/storm sewer"|"1"|"S"|"1968"|"15"|"0"|"Rust observed on piping. Remove rust and paint piping. Provide identification."|"1"|"UTIL"|"BELOW"|"S"|"2000"|"10"|"0"|"8 wall packs and 2 pole mounted flood lights for site illumination. Wall packs have yellowed lenses and recommend replacing."|"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"1"|"S"|"1968"|"10"|"0"|"Recommend leveling southeast catch basin."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"10"|"0"|"Recommend leveling southeast parking lot catch basin and re-sealing parking lot."|"1"|"CONCRETE"|"S"|"2007"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"15"|"0"||"0"||||"0"||"1"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"7"|"0"|"some broken tiles"|"0"||||"0"||"1"|"S"|"S"|"1968"|"10"|"0"|"Some doors do not have lever handles."|"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"1968"|"3"|"51600"|"Would recommend replacing as equipment has exceeded its useful life and operation."|"1"|"S"|"2000"|"7"|"0"||"1"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1968"|"7"|"0"|"Worn and staining in some areas."|"1"|"COMMON"|"S"|"1969"|"15"|"0"||"1"|"COMMON"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"15"|"0"||"1"|"METAL"|"S"|"2007"|"15"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1969"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1969"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1968"|"10"|"0"||"1"|"IRON"|"S"|"1968"|"10"|"0"|"Remove debris from and clean floor drain strainers."|"1"|"NAT_GAS"|"U"|"2001"|"3"|"5000"|"Expansion tank. Flue vent piping termination is not code compliant."|"1"|"S"|"1968"|"10"|"0"|"Wall mounted electric water cooler. Non ADA compliant."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"U"|"1968"|"3"|"135000"|"Reaching end of useful life."|"1"|"U"|"1968"|"3"|"45000"|"Multi-zone air handling unit reaching end of useful life"|"1"|"U"|"2002"|"3"|"15000"|"System piping in boiler room in bad condition."|"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"U"|"1968"|"3"|"22575"|"Fan shut down for HVAC units is not present. Recommend replacing fire alarm system with new addessable system."|"1"|"U"|"1968"|"3"|"22575"|"Recommend replacing fire alarm system with new addressable system"|"0"||||"0"||"1"|"U"|"1990"|"3"|"4515"|"Egress lighting is not present. Recommend providing."|"0"||||"0"||"1"|"1"||"The interior of the building has accessible routes, but no ADA bathrooms. The exterior is accessible."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"|"Some noise in copy room."|"DAYLIGHT,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"|"0"|"FAIR"||"301265"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/22/2010 11:39:05 AM| 400|"Mohawk CSD"|"21050204"|"BUS GARAGE"|"5015"|"09/09/2010"|"22 EAST MAIN STREET"|"MOHAWK"|" 13407"|"ANNUAL"|"10/01/2011"|"1999"|"6860"|"2"|"1"|"0"|"DISTRICT"|"OTHER"|"Bus Maintenance/Dispatch Office"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"OTHER"|"Dispatch Office"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"25"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"40"|"0"||"1"|"S"|"1999"|"25"|"0"||"0"||||"0"||"1"|"S"|"1999"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"15"|"0"||"1"|"CONCRETE"|"S"|"1999"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"40"|"0"||"1"|"S"|"1999"|"40"|"0"||"1"|"S"|"1999"|"30"|"0"||"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"30"|"0"||"0"||||"0"||"1"|"1"|"S"|"1999"|"30"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1999"|"15"|"0"||"1"|"COMMON"|"S"|"1999"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"40"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"1999"|"40"|"0"||"1"|"METAL"|"S"|"1999"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1999"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1999"|"25"|"0"||"1"|"IRON"|"S"|"1999"|"25"|"2000"|"Clean out covers and fresh air inlet should be installed at house trap"|"1"|"NAT_GAS"|"S"|"1999"|"5"|"8000"|"Hot water heater is nearing end of useful life"|"1"|"S"|"1999"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"25"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Radiant slab in maintenance bays"|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$10,000"|"S"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/22/2010 11:41:48 AM| 402|"Port Jefferson UFSD"|"58020602"|"SPRING STREET SCHOOL"|"0003"|"10/25/2010"|"SPRING STREET"|"PORT JEFFERSON"|"11777-1980"|"ANNUAL"|"05/01/2011"|"1914"|"53069"|"3"|"3"|"0"|"LSD_NDE"|"INSTRUCT"||"100"|"9,10,11,12"|"0"|"1"|"0"|"100"|"0"|"0"|||"17"|"14600"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"2"|"9000"|"S"|"1986"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"15"|"0"||"1"|"SITESEPT"|"S"|"1970"|"8"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2008"|"25"|"0"||"1"|"S"|"1964"|"5"|"0"|"Below grade roof drain piping inspected via camera and cleaned 2008."|"0"||||"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"5"|"35000"|"Repave front entry drive."|"1"|"ASPHALT"|"S"|"2008"|"15"|"42000"|"Sidewalks in several locations need to be replaced."|"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"1"|"S"|"1964"|"15"|"6000"|"Install closer on door from AP office to storage room. Provide two (2) separations between boiler room and through to basement office."|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"15"|"0"|"Recommend long range plan be established to continue replacement of sagging 2x4 ceilings.When 2x4 ceilings are replaced, upper concealed spline and tin ceilings should be removed & disposed of off site. Reinstall 2x4 ceiling tiles."|"1"|"S"|"1964"|"3"|"0"||"1"|"S"|"S"|"2008"|"12"|"0"|"Long range plan for replaement of interior wood doors should be considered."|"1"|"S"|"1964"|"15"|"19000"|"Replace railings at upper viewing area and steps up to Art Room."|"1"|"E"|"2008"|"20"|"0"||"1"|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"6"|"184000"|"Recommend replacement of remaining T12 light fixtures with T8 fixtures in all locations and T5 lighting in gym and cafeteria. Additionally all spaces will be equipped w/ occupancy sensors."|"1"|"1"|"S"|"1970"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"10"|"0"||"0"|"COMMON"|"E"|"2008"|"12"|"0"||"1"|"COMMON"|"S"|"1964"|"25"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"SLABGRADE,PRECAST,WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"25"|"0"||"1"|"MASONRY"|"S"|"2008"|"25"|"0"||"1"|"MASONRY"|"S"|"2008"|"20"|"0"||"E"|"E"|"1"|"1"|"2008"|"20"|"2500"|"Replace existing hollow metal door at upper floor off fire escape."|"1"|"S"|"1964"|"10"|"41000"|"Install intermediate handrail at mid-point of exterior stairs where stair distance exceeds 88" in width. Replace railing and reconstruct retaining walls at rear ramp to custodial area. Cement parge & repair main steps at North entrance."|"1"|"S"|"1"|"2000"|"8"|"65000"|"Wire brush and paint entire fire escape. Provide diagonal bracing at upper landing."|"1"|"ALUMINUM"|"E"|"Y"|"2008"|"25"|"168000"|"Replace gym windows, locker room, hallway to gym and weight room. All remaining windows were replaced in 2008."|"METONMET,WOODONWOOD,OTHER"|"SINGLEPLY,BUILTUP,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"10"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2008"|"10"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1964"|"8"|"0"||"1"|"OIL"|"S"|"1995"|"7"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||"1"|"BOILERWATE,BOILERSTEA"||"S"|"2008"|"35"|"0"||"0"|"E"|"2008"|"35"|"0"||"1"|"S"|"2008"|"8"|"0"|"Window A/C units."|"1"|"E"|"2008"|"20"|"0"|"Provide mechanical fresh air ventilation in accordance with the Mechanical Code of New York State and the State Education Dept requirements."|"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"1957"|"5"|"0"||"1"|"E"|"2008"|"15"|"0"|"New DDC system installed."|"1"|"S"|"1997"|"6"|"0"||"1"|"S"|"1997"|"6"|"0"||"1"|"S"|"2003"|"2003"|"38000"|"New hoses installed on each floor - 2003."|"1"|"S"|"1995"|"6"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"1"|"1"||"GOOD"||"600500"|"S"|"1"|"John A. Grillo Architect PC"|"1213 Main Street, Port Jefferson "|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/22/2010 11:59:48 AM| 403|"BOCES Albany-Schoh-Schen"|"01900000"|"Maywood school"|"0018"|"7/20/2010"|"1979 Central Avenue"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1926"|"46700"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"100"|"9,10,11,12"|"0"|"0"|"1"|"100"|"0"|"0"|||"15"|"12000"|"ADMIN,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"15"|"0"|"Water main was reconstructed last year. Underground water service."|"1"|"MUN_UTILIT"|"S"|"2008"|"15"|"0"|"Connections replaced two years ago. Underground sanitary service."|"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1950"|"10"|"0"|"Building fed by aerial AND underground lines. Transformer in vault attached to building; vault is secured by utility company lock. BOCES has no access."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"SURFACEH2O"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1926"|"4"|"44000"|"Age of existing paving unknown. Resurfacing of paving recommended."|"1"|"ASPHALT"|"S"|"1926"|"4"|"0"|"Age of existing paving unknown."|"0"||||"0"||"1"|"S"|"1960"|"15"|"0"|"N"|"Experiencing some problems with sink holes."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1980"|"15"|"0"|"Some small shrinkage cracks - should be sealed."|"1"|"S"|"1961"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"16000"|"Replace Gym Ceiling"|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"|"Consider replacement of older interior doors."|"1"|"S"|"1926"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"4"|"112000"|"Replace electrical distribution components. Some components date back to the 1950's and are obsolete and beyond their useful life. System functions, but significant replacement work is highly recommended. "|"1"|"S"|"2007"|"15"|"0"||"1"|"0"|"S"|"2007"|"4"|"110000"|"Replace intercom system. Communication system past useful life. Repair parts difficult to obtain or not available. Cost assumes 40 stations (intercom)."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"1961"|"15"|"0"||"1"|"COMMON"|"S"|"1926"|"4"|"71000"|"Consider replacement of wood gym floor. Wood floor in gym refinished a couple of years ago."|"SLABGRADE,CONCRMETAL,OTHER"|"Cast-in-place concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1980"|"15"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1980"|"15"|"0"|"Seal expansion/contraction cracks."|"1"|"MASONRY"|"S"|"2009"|"15"|"0"|"Chimney re-pointed last year. Brick chimney with concrete cap."|"1"|"MASONRY"|"S"|"1951"|"15"|"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"|"All exterior doors have been replaced."|"1"|"S"|"2007"|"15"|"0"|"Replace exterior ramps. Add railing at 1951 wing."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2010"|"15"|"0"|"Windows replaced 2009/2010"|"METONMET,WOODONWOOD,WOODONMET"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"4"|"8000"|"Library Roof - needs replacement."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1960"|"15"|"0"|"Repairs performed as required."|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1960"|"15"|"0"|"Repairs performed as required."|"1"|"NAT_GAS"|"S"|"2005"|"4"|"9000"|"Heater is nearing end of useful life."|"1"|"S"|"1960"|"15"|"0"|"Original fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1988"|"10"|"169000"|"Well-mclain cast iron boilers"|"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"S"|"1960"|"4"|"135000"|"Install new unit ventilators."|"1"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"4"|"43000"|"Original pneumatic system nearing end of useful life. Replace controls with equipment upgrade projects."|"1"|"S"|"2000"|"15"|"0"|"Zoned system with 5 zones."|"1"|"S"|"2000"|"15"|"0"|"Gym detectors require heavier duty protective caps."|"1"|"S"|"2005"|"2005"|"0"|"Single tank fire suppression system for kitchen hood."|"1"|"S"|"1988"|"4"|"16000"|"Some units past useful life, additional units needed in halls and gym."|"0"||||"0"||"1"|"1"|"0"|"BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance. BOCES is implementing required improvements."|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"0"|"1"|"0"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"FAIR"||"725000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/22/2010 11:59:54 AM| 404|"Yorkshire-Pioneer CSD"|"04350106"|"DELEVAN ELEMENTARY"|"0001"|"11/15/2010"|"30 SCHOOL STREET"|"DELEVAN"|" 14042"|"ANNUAL"|"07/01/2011"|"1957"|"97,251"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"447"|"K,1,2,3,4"|"0"|"1"|"1"|"447"|"0"|"0"|||"28"|"22,587"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"S"|"1990"|"5"|"25,000"|"UPGRADE GAS SERVICE IN CURRENT PROJECT."|"1"|"UTIL"|"BELOW"|"E"|"2007"|"5"|"20,000"|"UPGRADE FRONT PARKING SITE LIGHTING. ELECTRICAL SERVICE HAS 37 YEARS"|"0"||||"0"||"1"|"U"|"1957"|"5"|"100,000"|"NEED TO MODIFY POINT OF DISCHARGE."|"1"|"U"|"1957"|"5"|"30,000"|"ADD CATCH BASINS"|"0"||||"0"||"0"|"SURFACEH2O"||"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"3"|"54,000"|"REPLACE PAVEMENT AT BUS LOOP AND PARKING LOT."|"1"|"CONCRETE"|"S"|"2008"|"20"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1989"|"30"|"0"||"1"|"S"|"1957"|"30"|"0"||"1"|"S"|"1989"|"30"|"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"U"|"1989"|"3"|"72,000"|"REPLACE LOCKERS IN ORIGINAL BUILDING AND PAINT 1989 LOCKERS."|"1"|"S"|"S"|"1989"|"10"|"0"||"1"|"S"|"1957"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"1"|"S"|"2007"|"5"|"20,000"|"ADDITIONAL GENERAL PURPOSE RECEPTACLES IN VARIOUS AREAS. DISTRIBUTION GEAR 20 YEARS."|"1"|"S"|"2007"|"5"|"420,000"|"REPLACE T12 FLUORECSENT, INTERIOR HID LUMINAIRES, AUDITORIUM DIMING SYSTEM AND GYMNASIUM LIGHTING."|"1"|"1"|"S"|"1999"|"5"|"400,000"|"REPLACE CLOCK, PUBLIC ADDRESS SYSTEM, SUB-SOUND AND CAT-V SYSTEMS."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1991"|"2"|"176,000"|"REPLACE CARPET IN MISCELLANEOUS CLASSROOMS."|"1"|"INSTRUCT,COMMON"|"S"|"1991"|"10"|"0"||"1"|"COMMON"|"S"|"1991"|"10"|"0"||"1"|"COMMON"|"U"|"1957"|"2"|"5,500"|"REFINISH GYMNASIUM FLOOR."|"SLABGRADE,OTHER"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1989"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1989"|"30"|"0"||"1"|"MASONRY"|"S"|"1957"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1999"|"1"|"42,000"|"REPLACE SECURITY DEVICES AND CONTROL PANEL."|"1"|"S"|"1957"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"20"|"0"||"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"15"|"0"||"1"|"PLASTIC"|"S"|"2000"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"U"|"1996"|"5"|"50,000"|"HOT WATER RECIRCULATION SYSTEM UPGRADE, WALL ADN ROOF HYDRANTS"|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1996"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2008"|"15"|"0"||"1"|"U"|"2007"|"5"|"75,000"|"REPLACE FIXTURES."|"0"||"1"|"BOILERWATE,FURNACE"||"S"|"2008"|"5"|"80,000"|"REPLACE POWER BURNERS AT BOILERS."|"1"|"S"|"2008"|"5"|"0"|"UPGRADES INCLUDED WITH CURRENT CAPITAL PROJECT."|"1"|"S"|"2008"|"5"|"30,000"|"REPLACE SPLIT A/C AT SERVER EQUIPMENT ROOM AND ADD A/C TO OFFICE."|"1"|"S"|"2008"|"5"|"60,000"|"REPLACE DRAIN PANS AT AUDITORIUM AIR HANDLING UNITS AND ADD CRAWLSPACE VENTILATION."|"1"|"S"|"1990"|"5"|"40,000"|"REPLACE MISCELLANEOUS PIPING AND ADD ISOLATION VALVES."|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"5"|"100,000"|"REPLACE ORIGINAL CONTROL VALVES AT CLASSROOM UNIT VENTILATORS."|"1"|"S"|"1996"|"6"|"0"||"1"|"S"|"2007"|"1"|"60,000"|"UPGRADE SYSTEM TO ADDRESSABLE TYPE."|"0"||||"0"||"1"|"U"|"1990"|"0"|"70,000"|"INSTALL EXTERIOR EMERGENCY LIGHTING AND UPGRADE INTERIOR EMERGENCY LIGHTING (CURRENTLY UNDER CONTRACT). INSTALL LED EXIT SIGNAGE."|"1"|"U"|"1990"|"0"|"60,000"|"SEGREGATE STANDBY AND EMERGENCY CIRCUITS AND NEW OUTDOOR GENERATOR (CURRENTLY UNDER CONTRACT)."|"1"|"1"|"93,000"|"PROVIDE HANDICAP ACCESSIBILITY IN 1989 ADDITION AND KINDERGARDEN WIND TOILET ROOMS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"0"|"1"|"1"|"0"|"SPOT"|"0"|"1"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"||"1"||"FAIR"||"2,000,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES ARCHITECTS"|"5757 MAIN STREET, WILLIAMSVILLE, NEW YORK 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/22/2010 12:12:39 PM| 405|"Alden CSD"|"14010106"|"Alden Elementary/Middle School"|"0004"|"01/21/2010"|"Crittenden Road"|"Alden, New York"|" 14004"|"ANNUAL"|"12/01/2010"|"1914"|"166125"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"888"|"3,4,6,7"|"0"|"1"|"1"|"888"|"0"|"0"|||"36"|"32400"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2009"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1951"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"|"No identification "|"1"|"UTIL,SELF"|"ABOVE"|"E"|"1998"|"10"|"0"||"1"|"U"|"1951"|"15"|"0"||"0"||||"0"||"1"|"S"|"1914"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2001"|"10"|"0"|"Patch apron off street"|"1"|"CONCRETE,ASPHALT"|"S"|"2001"|"10"|"0"|"Minor concrete repair may be required"|"1"|"S"|"1988"|"5"|"0"|"Some rusting pieces of equipment on playground. Wood is pressure treated and horizontal sections are showing signs of cracking and separation"|"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"15"|"0"|"Rebar showing. Stress cracks"|"1"|"S"|"2001"|"20"|"0"|"Minor cracking above door Room 151"|"1"|"S"|"2001"|"20"|"0"|"Minor step cracking in block walls"|"1"|"S"|"2009"|"10"|"0"|"ACT tiles are broken, gouged, and discolored"|"1"|"S"|"2001"|"15"|"0"|"Some rust, scratches, dents, and missing parts"|"1"|"S"|"S"|"2009"|"10"|"0"|"No panic hardware on 1951 stair doors"|"1"|"S"|"2001"|"15"|"0"|"No extension of handrail at end of stair"|"1"|"S"|"1992"|"10"|"0"|"Location of elevator is not acceptable under the current building cod, but may have been allowed at the time of installation"|"1"|"1"|"S"|"2001"|"10"|"0"|"Vintage panels have exceeded their useful life and should be replaced"|"1"|"S"|"2001"|"10"|"0"|"Some yellowing and a few cracked lenses"|"1"|"1"|"S"|"1998"|"7"|"0"|"Area condition for equipment connection points is detrimental. This distribution point should be relocated"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"7"|"0"|"Some staining"|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"|"Some stained tiles in conference space"|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"|"Terrazzo tile-maintenance is hard to keep up because of joints in tile"|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"10"|"0"||"SLABGRADE,CONCRMETAL,PRECAST,WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"1"|"1"|"0"|"S"|"2001"|"20"|"0"|"Minor deflection in structural beams causing minor cracks in floor"|"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"2001"|"15"|"0"|"Deterioration on some window sills"|"1"|"MASONRY"|"S"|"1935"|"7"|"0"|"Cracked bricks"|"1"|"OTHER"|"S"|"1914"|"15"|"0"|"Wood parapet-minor chipping on top portion"|"S"|"S"|"1"|"1"|"2001"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"|"Concrete foundation is spalling and cracking. Stairs are rusted"|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"2001"|"10"|"0"|"Room 355 no rescue window signage"|"WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"10"|"0"|"Numerous areas of standing water and debris around around roof drains. U-joists show no sign of concerns on second floor"|"1"|"PLASTIC"|"U"|"1996"|"10"|"0"|"Numerous areas of standing water and debris around around roof drains. U-joists show no sign of concerns on second floor"|"1"|"COPPER"|"S"|"1987"|"10"|"0"|"No RPZ or identification"|"1"|"IRON,GALVANIZED,PVC"|"S"|"1951"|"7"|"0"|"Floor drains missing covers"|"1"|"NAT_GAS"|"S"|"2009"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"|"Water coolers are not ADA compliant"|"1"|"CV,OTHER"|"1"|"BOILERWATE"||"S"|"1997"|"10"|"0"||"1"|"S"|"1992"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"7"|"0"||"1"|"S"|"1951"|"7"|"0"|"Pumps show evidence of leaking"|"1"|"S"|"2001"|"10"|"0"|"1951 and 1961 areas need cleaning or replacement"|"1"|"S"|"1997"|"20"|"0"|"Not entire building is on DDC system"|"1"|"S"|"1998"|"7"|"0"||"1"|"S"|"1998"|"7"|"0"|"Currently no notification devices in classrooms"|"1"|"S"|"1998"|"1998"|"0"|"kitchen fire suppression hood"|"1"|"U"|"2009"|"3"|"58,143.75"|"Existing exit signs have exceeded their useful life, are incandescent, an should be replaced"|"1"|"S"|"2002"|"10"|"0"||"1"|"1"|"0"|"There are accessible interior and exterior routes"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"Recommend more energy efficient lighting fixtures with adequate distribution for the spaces"|"0"|"0"|"0"|"0"|"1"|"ACTIVE"|"1"|"CLASSROOMS"||"0"|||"1"|"1"|"0"|"No evidence of mold or mildew, but areas of moisture penetration"|"0"|"0"|"0"|"0"|"1"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,SUMPPUMP,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"858,152.75"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/22/2010 12:58:07 PM| 408|"BOCES Western Suffolk"|"58930000"|"Administration Building A"|"1035"|"07/14/2010"|"507 DEER PARK ROAD "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1970"|"23392"|"3"|"2"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"||"0"|"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"17"|"0"||"1"|"SITESEPT"|"S"|"2009"|"12"|"0"||"1"|"S"|"2009"|"17"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"12"|"0"||"0"||||"0"||"0"||||"0"||"1"|"E"|"2009"|"18"|"0"|"Water pool at South side grade."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2009"|"1"|"20,000"|"Renovate Entrance driveway at front of building."|"1"|"CONCRETE"|"S"|"2009"|"19"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"5"|"0"||"1"|"S"|"1983"|"7"|"0"||"1"|"S"|"2009"|"7"|"0"||"1"|"U"|"2009"|"1"|"25,000"|"Replace ceiling as required in original building."|"0"||||"0"||"1"|"S"|"S"|"2009"|"2"|"0"|"Door at West side of new addition not closing properly."|"1"|"E"|"1983"|"12"|"0"||"1"|"S"|"1983"|"7"|"0"||"1"|"1"|"S"|"2009"|"7"|"0"||"1"|"U"|"2009"|"7"|"5,000"|"Replace fixtures in original building."|"1"|"1"|"S"|"2009"|"9"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"1"|"COMMON"|"S"|"2010"|"10"|"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"7"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"U"|"2009"|"1"|"50,000"|"Renovate wood shingles on original building."|"1"|"MASONRY"|"S"|"1983"|"7"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2009"|"18"|"0"||"1"|"U"|"2009"|"1"|"25,000"|"Replace wood retainig wall at South Emtrance."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2009"|"19"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"S"|"2009"|"12"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2009"|"2"|"0"||"1"|"IRON,GALVANIZED"|"S"|"2009"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"9"|"0"||"1"|"E"|"2009"|"2"|"0"|"Cracked WC in Women Toilet Rm. needs to be replaced."|"0"||"1"|"BOILERWATE,FURNACE"||"S"|"2009"|"13"|"0"||"1"|"S"|"2009"|"14"|"0"||"1"|"S"|"2009"|"13"|"0"||"1"|"S"|"2009"|"13"|"0"||"1"|"S"|"1983"|"8"|"0"||"1"|"S"|"2009"|"13"|"0"||"1"|"E"|"2009"|"19"|"0"||"1"|"S"|"2009"|"9"|"0"||"1"|"S"|"2009"|"9"|"0"||"0"||||"0"||"1"|"S"|"2009"|"9"|"0"||"1"|"U"|"1975"|"1"|"100,000"|"Replace generator."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"225,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/22/2010 1:37:13 PM| 409|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #7-CULINARY ARTS/NRSNG "|"0049"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"9865"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"57"|"9,10,11,12"|"0"|"0"|"0"|"57"|"0"|"0"|||"4"|"2922"|"CAFE,HLTHSUITE,KITCHEN,SCIENCELAB,OTHER"|"Dedicated instructional lab for nursing, culinary arts, food service,early childhood educations."|"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"10"|"0"|"New slurry seal is needed."|"1"|"CONCRETE"|"S"|"1970"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"2"|"25,000"|"Replace outdated panels."|"1"|"S"|"1970"|"5"|"45,000"|"Replace existing with T8 fixtures."|"1"|"1"|"S"|"2002"|"10"|"15,000"|"Provide new PA System."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"1"||"S"|"1970"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2007"|"20"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"4"|"150,000"|"Seams and flashing are deteriorating."|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON,COPPER"|"S"|"1971"|"6"|"0"||"1"|"ELECTRIC"|"S"|"1971"|"2"|"3,000"|"Provide ASME water heater, tank-less gas water heater."|"1"|"S"|"1971"|"2"|"3200"|"Replace faucet trim (4)."|"0"||"1"|"OTHER"||"S"|"2002"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2007"|"5"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2007"|"5"|"0"||"0"||||"0"||"1"|"1"|"150,000"|"Relocate kitchen and nursing program (more accessible). "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"309,400"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/22/2010 1:48:45 PM| 410|"Lockport City SD"|"40040001"|"ANNA MERRITT ELEMENTARY SCHOOL"|"0010"|"06/24/2010"|"389 GREEN STREET "|"LOCKPORT "|" 14094"|"ANNUAL"|"12/01/2010"|"1959"|"48799"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"307"|"K,1,2,3,4,5"|"0"|"1"|"0"|"307"|"0"|"0"|||"23"|"15514"|"ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1958"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1958"|"15"|"0"||"1"|"S"|"1958"|"15"|"0"||"1"|"SELF"|"ABOVE"|"U"|"2005"|"4800"|"0"|"Fixtures are locally controlled by photocell and lenses have yellowed. Some are cracked and deterioration of surface paint is noticable."|"1"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"1958"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1961"|"7"|"0"|"Recommend patching near catch basins. Patching required in multiple locations throughout within the next three years."|"1"|"CONCRETE"|"S"|"1992"|"15"|"0"|"Several cracks and multiple levels due to heaving may pose tripping hazard."|"1"|"S"|"1992"|"5"|"0"|"Graffiti, rusted metal poles and stairs, pieces missing from equipment"|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"10"|"0"||"0"||||"0"||"1"|"S"|"1992"|"15"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1961"|"7"|"0"|"Delamination and deteriorating of wood in multiple areas"|"1"|"S"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"1992"|"3"|"195196"|"Recommend replacing secondary distribution."|"1"|"U"|"2002"|"3"|"3750"|"Recommend replacing hem with fluorescent high bay lighting fixtures for energy savings and instant on."|"1"|"1"|"S"|"1992"|"7"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1992"|"7"|"0"|"Some pulls and wear marks, especially in library"|"1"|"INSTRUCT,COMMON"|"S"|"1992"|"10"|"0"|"Staining near doors"|"1"|"INSTRUCT,COMMON"|"U"|"1992"|"3"|"69720"|"Major cracking throughout whole building addition in 1992 terrazzo."|"1"|"INSTRUCT,COMMON"|"S"|"1961"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1992"|"10"|"0"||"1"|"MASONRY"|"S"|"1962"|"7"|"0"|"Recommend brick repointing"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"|"Concrete is cracked in a few places under posts at ramp."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"7"|"0"|"Rescue windows are an awning type in some areas and casement type in other areas."|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"10"|"0"||"1"|"PLASTIC"|"S"|"1993"|"10"|"0"||"1"|"COPPER"|"S"|"1961"|"10"|"0"||"1"|"IRON"|"S"|"1961"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1958"|"7"|"0"||"1"|"S"|"1992"|"10"|"0"|"Drinking fountain and electric water cooler. Non ADA compliant."|"1"|"CV"|"1"|"BOILERWATE"||"U"|"1959"|"3"|"130000"|"Flue duct has asbestos insulation. Boilers reaching end of useful life."|"1"|"S"|"1958"|"10"|"0"||"1"|"S"|"1992"|"5"|"0"||"1"|"U"|"1992"|"5"|"195000"|"Units reaching end of useful life."|"1"|"S"|"2009"|"5"|"0"|"Motors replaced in 2009. Rest of the pump is older. Covered with asbestos insulation."|"1"|"S"|"1992"|"10"|"0"|"Ductwork is original to building. Recommend cleaning or replacement."|"1"|"S"|"1992"|"15"|"0"||"1"|"E"|"2008"|"10"|"0"||"1"|"E"|"2008"|"10"|"0"||"1"|"S"|"1961"|"1961"|"0"||"1"|"S"|"2002"|"7"|"0"||"0"||||"0"||"1"|"1"|"0"|"There are accessible interior and exterior routes."|"FAIR"|"Interior of building is better in appearance than exterior. Landscaping on exterior needs to be weeded and cleaned up. "|"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"Gym lighting seems inadequate."|"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|"1000"|"Evidence of water damage to ceiling in 1958 wing."|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"1"|"FAIR"|"Building is stuffy. Air should be circulated better."|"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"GOOD"||"598466"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/22/2010 1:52:22 PM| 412|"BOCES Albany-Schoh-Schen"|"01900000"|"Schoharie Vo Tech Center"|"0001"|"7/20/2010"|"Rt. 30 A"|"Schoharie"|" 12157"|"ANNUAL"|"10/1/2011"|"1972"|"30866"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"165"|"9,10,11,12"|"0"|"1"|"0"|"165"|"0"|"0"|||"0"|"0"|"ADMIN,KITCHEN,TECHSHOP"||"1"|"1"|"8000"|"0"|"0"|"S"|"1992"|"15"|"0"||"1"|"WELL"|"S"|"1995"|"15"|"0"|"Parts of line have been replaced in 1995 400 feet in back of site Using 2nd well now first was in front"|"1"|"SITESEPT"|"S"|"1972"|"15"|"0"|"3 stage filter bed in front of building Tank is pumped every year BOCES has SPEDES Permit"|"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1972"|"15"|"0"|"Utility aerial lines to last pole Underground to transformer Underground from utility transformer to service equipment"|"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"1"|"SURFACEH2O,ONSITE"||"0"|"S"|"1972"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1972"|"4"|"51000"|"Recommend resurfacing paving."|"1"|"ASPHALT"|"S"|"1972"|"4"|"0"|"Resurface walks included in paving budget"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1994"|"15"|"0"|"Exposed roof deck in shops"|"0"||||"0"||"1"|"S"|"S"|"1998"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1972"|"15"|"0"|"Sufficient capacity spare parts are obtainable"|"1"|"S"|"1972"|"10"|"0"|"T12s replaced with T8s as ballasts fail or with room renovations"|"1"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1972"|"15"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1972"|"15"|"0"|"Recommend painting lintels and caulking transite fascia joints"|"1"|"MASONRY"|"S"|"1972"|"15"|"0"||"1"|"MASONRY"|"S"|"1972"|"15"|"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"|"Maintenance plan in place to replace doors as needed Some doors are older and will need replacement"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1972"|"10"|"0"|"Single glazed aluminum frame windows Consider replacement for improved thermal performance"|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"540000"|"Single ply hypalon roofing Warranty has expired and roofing near end of useful life"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"1972"|"15"|"0"||"1"|"OIL"|"E"|"2005"|"15"|"0"||"1"|"S"|"1973"|"15"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"Unit ventilation"|"S"|"1972"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1972"|"10"|"0"|"Ductless split cooling"|"1"|"S"|"1972"|"4"|"51000"|"repair and recommission existing ventilation system through out building"|"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"4"|"43000"|"Upgrade existing systems"|"1"|"S"|"2002"|"15"|"0"|"Zoned system"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"1999"|"0"|"Single tank kitchen hood suppression system inspected annually"|"1"|"S"|"1999"|"10"|"0"|"Additional emergency lights needed in corridors"|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_NOT_Ful"|"FAIR"|"T12 to T8 fixture replacement in progress in kitchen classroom"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"POOR"|"See ventilating equipment section"|"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"735000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/22/2010 1:58:07 PM| 414|"Argyle CSD"|"64010104"|"Argyle Central School"|"0001"|"08/24/2010"|"5023 State Route 40"|"Argyle"|" 12809"|"ANNUAL"|"01/01/2011"|"1939"|"149,700"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"640"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"640"|"0"|"0"|||"85"|"141,800"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"2000"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"50"|"0"||"1"|"SITESEPT"|"U"|"2000"|"5"|"$60,000"|"Valve vaults are failing."|"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"40"|"0"||"1"|"S"|"2000"|"40"|"0"||"1"|"S"|"2000"|"50"|"0"||"1"|"S"|"2000"|"50"|"0"||"0"|||"50"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2000"|"50"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"2"|"$130,000"|"Resurfacing main parking and elementary drive."|"1"|"CONCRETE"|"S"|"2000"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"U"|"2000"|"0"|"$150,000"|"N"|"Tennis courts surfaces non-playable."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"95"|"0"||"1"|"S"|"2000"|"75"|"0"||"1"|"S"|"2000"|"40"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"60"|"0"||"1"|"S"|"2000"|"60"|"0"||"1"|"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"20"|"0"||"1"|"COMMON"|"S"|"2000"|"75"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"25"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"95"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"70"|"0"||"1"|"METAL"|"S"|"2000"|"30"|"0"||"1"|"MASONRY"|"S"|"2000"|"40"|"0"||"S"|"S"|"1"|"1"|"2000"|"10"|"0"||"1"|"S"|"2000"|"30"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"20"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,SLATE,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"2007"|"20"|"$72,000"|"1974 wing roof past life expectancy."|"1"|"PLASTIC"|"S"|"2000"|"70"|"0"||"1"|"COPPER"|"S"|"2000"|"20"|"0"||"1"|"IRON"|"S"|"2000"|"20"|"0"||"1"|"OIL"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"$412,000"|"U"|"1"|"Sacco + McKinney Architects, PC"|"11 British American Blvd., Latham, NY 12110"|"518-783-8933"|"csacco@saccomckinney.com"|"Charles J. Sacco"|"015041"|"I ACCEPT"|12/22/2010 2:03:28 PM| 416|"Yorkshire-Pioneer CSD"|"04350106"|"PIONEER MIDDLE SCHOOL"|"0015"|"11/15/2010"|"OLD OLEAN ROAD"|"YORKSHIRE"|" 14173"|"ANNUAL"|"07/01/2011"|"1974"|"148,783"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"739"|"5,6,7,8"|"0"|"1"|"1"|"739"|"0"|"0"|||"45"|"36,504"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1975"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2007"|"20"|"0"||"1"|"S"|"2007"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"5"|"100,000"|"REPLACE SITE LIGHTING FIXTURES AND SOFTBALL LIGHTING FIXTURES."|"0"||||"0"||"0"|"S"|"1975"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"S"|"1975"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"1975"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2009"|"10"|"0"||"1"|"CONCRETE"|"U"|"2009"|"2"|"50,000"|"REPLACED MISCELLANEOUS WALKS."|"0"||||"0"||"1"|"S"|"1974"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1989"|"30"|"0"||"1"|"S"|"1974"|"30"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"U"|"2008"|"3"|"340,000"|"REPLACE CEILING AT MISCELLANEOUS CLASSROOMS."|"1"|"S"|"1974"|"2"|"280,000"|"REPLACE CORRIDOR LOCKERS."|"1"|"S"|"S"|"1974"|"15"|"0"||"1"|"S"|"1974"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"5"|"300,000"|"REPLACE ORIGINAL DISTRIBUTION EQUIPMENT."|"1"|"S"|"1975"|"5"|"450,000"|"REPLACE ORIGINAL LUMINAIRES AND INTERIOR HID LIGHTING, CAFETERIA."|"1"|"1"|"S"|"1999"|"510,000"|"5"|"REPLACE CLOCKS, POOL/GYMNASIUM SUB-SOUND SYSTEMS, OLD DATA CABLING AND UPGRADE BROADBAND SYSTEM."|"1"|"U"|"2007"|"2"|"40,000"|"REPLACE POOL MAIN DRAIN."|"1"|"INSTRUCT,COMMON"|"U"|"1996"|"2"|"228,000"|"REPLACE CARPET IN MISCELLANEOUS CLASSROOMS AND MEDIA CENTER."|"1"|"INSTRUCT,COMMON"|"S"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"1996"|"20"|"0"||"1"|"COMMON"|"U"|"1974"|"2"|"75,000"|"REPLACE GYM FLOOR."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1989"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1989"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"0"|"2007"|"3"|"189,000"|"REPLACE SECURITY DEVICES AND CONTROLS, REPLACE MISCELLANEOUS EXTERIOR DOORS."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1974"|"1"|"587,000"|"REPLACE WINDOWS AT ORIGIONAL BUILDING."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"1"|"PLASTIC"|"E"|"2009"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1975"|"5"|"60,000"|"REPLACE GATE VALVES WITH BALL VALVES. ADD ROOF DRAINS. ADD EMERGENCY SHOWER AND EYE WASH TO SHOPS."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1975"|"5"|"50,000"|"REPLACE STORM PIPE ADD ROOF DRAINS. REPLACE MISCELLANEOUS SANITATION PIPING."|"1"|"ELECTRIC"|"E"|"2008"|"20"|"0"||"1"|"S"|"2010"|"5"|"250,000"|"REPLACE OLD FIXTURES. REPLACE LOCKER ROOM SHOWERS."|"0"||"1"|"BOILERWATE,OTHER"|"ELECTRIC BOILERS"|"E"|"2008"|"15"|"0"||"1"|"S"|"1975"|"20"|"0"|"MUNICIPAL ELECTRIC SYSTEM."|"1"|"S"|"2008"|"5"|"1,980,000"|"REPLACE ORIGINAL CLASSROOM HEAT PUMPS, ROOF TOP AIR CONDITIONING UNITS AND POOL AIR HANDLING UNIT."|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"5"|"100,000"|"REPLACE ORIGINAL RADIATION, REPAIR MISCELLANEOUS PIPING AND REPLACE GLYCOL SYSTEM."|"1"|"U"|"2008"|"5"|"50,000"|"REPAIR POOL DUCTWORK AND DEMO WELDING HOOD AT SHOP."|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2007"|"17"|"0"|"UPGRADE TO ADDRESSABLE SYSTEM."|"1"|"S"|"2007"|"7"|"0"||"0"||||"0"||"1"|"S"|"2007"|"5"|"10,000"||"1"|"S"|"2007"|"27"|"0"||"1"|"1"|"160,000"|"PROVIDE HANDICAP ACCESSIBILITY AT SETS OF TOILET ROOMS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"0"|"1"|"GOOD"||"6,400,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES ARCHITECTS"|"5757 MAIN STREET, WILLIAMSVILLE, NEW YORK 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/22/2010 2:30:18 PM| 419|"Germantown CSD"|"10090204"|"Main Building"|"0001"|"11/02/2010"|"123 MAIN ST "|"GERMANTOWN "|" 12526"|"ANNUAL"|"01/01/2011"|"1923"|"138000"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"585"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"585"|"0"|"0"|||"63"|"32000"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10000"|"S"|"1993"|"20"|"0"|"Double wall tank with leak detection and monitoring in place. "|"1"|"WELL"|"S"|"2000"|"25"|"0"|"3 wells, water softener and chlorination system present."|"1"|"MUN_UTILIT"|"S"|"2000"|"25"|"0"|"2 grinder stations. Eliminate one station by making it gravity fed directly to main on Rt. 9G."|"1"|"S"|"2000"|"25"|"0"|"1000 ga. underground propane tank for science rooms and kitchen. 100 ga. above ground tank for boiler pilots. "|"1"|"UTIL"|"BELOW"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"20"|"0"|"Discharge to culvert. "|"0"||||"0"||"1"|"S"|"2000"|"25"|"0"|"Basins and paving rims in good condition in paved areas. Field drainage at baseball and softball fields is poor. Site field drainage should be expanded in the future. "|"1"|"S"|"2000"|"25"|"0"|"Drainage of site storm water. "|"0"|"MUNI,SURFACEH2O"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"15"|"0"||"1"|"CONCRETE"|"S"|"2000"|"7"|"0"|"Some cracking and heaving at the sidewalk and stairs at the bus loop. Replace exterior stair and railings. "|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"12"|"0"|"N"|"Baseball and softball fields require additional drainage. Majority of remaining fields are satisfactory. "|"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2000"|"20"|"0"|"Some water penetration in basement. Majority of infiltration from crawl space in tank room was contained. Monitor and repair old building basement towards from of building. "|"1"|"S"|"2000"|"20"|"0"||"0"|"S"|"2000"|"25"|"15000"|"Continue in house patching and painting. Walls in "red" corridor to be repaired. Monitor cracking at plaster trim in cafeteria. Recommend patching and reinforcement. "|"1"|"S"|"2000"|"6"|"12500"|"Replace old ceiling in the red corridor. "|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"S"|"2000"|"7"|"30000"|"Some remaining interior doors in the 1972 wing to be replaced and have updated ADA hardware installed. "|"1"|"S"|"2000"|"20"|"0"|"Some cracking in the 1923 wing stair landings. Structural supports and steel pan is sound but topping is cracking. Patch cracks to reduce tripping hazard. Extend railing height at upper landings in 1923 wing. "|"1"|"S"|"2005"|"7"|"0"|"Elevator okay. Stair lifts have motor problems. 1 motor replaced, 1 motor adjusted, remaining 2 lifts may have similar problems in the future. Possible fix is to change motors to single phase or 3 phase 208v."|"1"|"1"|"S"|"2000"|"8"|"0"|"Stage area electrical distribution upgrade should be considered in the future. Power and lights in tank room and basement area which are not in use should be removed. "|"1"|"S"|"2000"|"20"|"0"|"1923 wing corridors, stage area, gym lights, site lighting near break room and delivery area should be considered for upgrade for general lighting and energy efficiency. "|"1"|"1"|"S"|"1972"|"8"|"0"|"Bogen MultiCom 2000 in use. Consider upgrade in future. "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"0"|"Carpet in 1923 wing corridors and 1972 wing. "|"1"|"INSTRUCT,COMMON"|"E"|"2000"|"8"|"0"|"Abate VAT in three classrooms in 1972 wing and basement. Some expansion cracking in corridors."|"1"|"COMMON"|"S"|"1972"|"12"|"0"|"Tile in corridor of the 1st grade wing has cracking at the cove base. "|"1"|"INSTRUCT"|"S"|"2000"|"15"|"0"|"Stage floor needs refinishing. "|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"45"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"1"|"1"|"1"|"1"|"1"|"Lintel corrosion on 1923 and 1969 wings"|"S"|"2000"|"8"|"0"|"Crack at NE corner over tech shop. Sealer on stone copings is failing, open cracks. Areas of repointing on 1923 wing. Efflor. above caf. entrance. Clean lintels of corrosion and remove caulk at weeps. "|"1"|"MASONRY"|"S"|"1942"|"6"|"0"|"1923 chimney needs to be repointed and have a new cap installed or take chimney down. "|"1"|"MASONRY"|"S"|"1923"|"8"|"0"|"Coating on stones is failing. Gaps and cracks in copings will get worse with water infiltration. "|"S"|"S"|"0"|"1"|"2000"|"10"|"0"|"Aluminum doors on the 1923 wing need new hardware and weatherstripping. "|"1"|"S"|"1972"|"4"|"0"|"Replace stairs and handrails at the 1923 wing entrances and the 1972 wing to the bus loop. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"15"|"0"|"Some single pane dh alum. windows in 1972 wing are reaching the end of their useful life. Consider replacement in 5-8 years. "|"METONMET,CONMETMET,OTHER"|"SINGLEPLY,ASPHALT,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2004"|"15"|"0"|"Leakage seen under low roof over cafeteria entry. Replace ballasted roof and provide new flashings. this will remedy efflor. at this area also. Attach loose cable wires to parapet securely, tripping hazard. "|"1"|"PLASTIC"|"E"|"2004"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2007"|"25"|"0"|"Water softener installed in 2007. Monitor rusted flanges on water tank. "|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2000"|"25"|"0"||"1"|"OIL"|"S"|"2005"|"30"|"0"|"68 gallon storage water heater, Bock 177 gph at 90 degrees F rise. "|"1"|"S"|"2000"|"25"|"0"|"Convert remaining manual flush valves to touch free. "|"0"||"1"|"BOILERWATE,FURNACE,OTHER"|"unit ventilators"|"S"|"2000"|"25"|"0"|"Unit vents and heating / ventilation units. "|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"10"|"0"|"Split system AC units in nurse, admin., computer labs and other individual rooms. "|"1"|"S"|"2000"|"12"|"0"|"Add ductwork in HS to reduce noise. "|"1"|"S"|"2000"|"25"|"0"||"1"|"S"|"2000"|"25"|"0"||"1"|"S"|"2000"|"25"|"0"|"Building wide energy management system by American Automatix. District controls schedules and setpoints. "|"1"|"S"|"2000"|"15"|"0"|"Simplex addressable fire alarm control 4020. "|"1"|"S"|"2000"|"15"|"0"|"Storage room near IT room, consider adding a strobe unit, notification appliance. "|"1"|"S"|"2000"|"2000"|"0"|"School kitchen hood with Ansul system. "|"1"|"S"|"2000"|"15"|"0"|"Add emergency light to tank room. "|"0"||||"0"||"1"|"0"|"0"|"HC modifications should include handrails modifications at stairs on 1923 wing and replacing remaining door knobs with lever handles. "|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"1"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"260000"|"S"|"1"|"Sammel Architecture"|"332 Route 100 Somers, NY 10589"|"914-276-0777"|"ds@sammelarchitecture.com"|"David Sammel"|"023158"|"I accept"|12/22/2010 3:15:04 PM| 420|"Lockport City SD"|"40040001"|"Charles Upson Elementary"|"0008"|"06/29/2010"|"28 HARDING AVENUE "|"LOCKPORT "|" 14094"|"ANNUAL"|"12/01/2010"|"1954"|"80098"|"1"|"4"|"0"|"PART"|"INSTRUCT"||"525"|"K,1,2,3,4,5"|"0"|"1"|"1"|"525"|"0"|"0"|||"30"|"17541"|"ART,AUDITORIUM,CAFE,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED,TEACHRSRC,OTHER"|"OT/PT"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"15"|"0"||"1"|"S"|"1954"|"10"|"0"|"Rust observed on piping and fittings. Re-paint piping and fittings."|"1"|"UTIL"|"BELOW"|"S"|"2005"|"7"|"0"|"Perimeter wall packs have discolored lens and recommend replacing, lighting controlled locally by photocell."|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"5"|"0"|"Catch basins at street were clogged with debris. School parking lots were clear."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"15"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"7"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"|"Chipped, stained, and broken tiles"|"1"|"U"|"1996"|"3"|"14444.46"|"Bent shelves, rusting. One master locker opens all of the other lockers."|"1"|"S"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"|"Railings do not extend past first tread."|"0"||||"0"||"1"|"1"|"U"|"1996"|"3"|"160196"|"50% of the secondary electrical distribution is vintage of original construction. Recommend replacing."|"1"|"U"|"1996"|"3"|"144177"|"1x4 industrial lighting fixtures 2 lamp t8 installed behind white egg crates and 6 inch incandescent down lights by entrance to classroom. Recommend replacing all lighting for fixtures suitable to teaching spaces."|"1"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1996"|"3"|"14769.50"|"Very worn with stains, pulls, and wear marks."|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"10"|"0"||"1"|"COMMON"|"S"|"1996"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"15"|"0"||"SLABGRADE,OTHER"|"Cast in place"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"15"|"0"||"1"|"MASONRY"|"S"|"1954"|"15"|"0"||"1"|"MASONRY"|"S"|"1996"|"15"|"0"||"S"|"S"|"0"|"1"|"1996"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,OTHER"|"S"|"Y"|"1996"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2004"|"7"|"0"||"1"|"PLASTIC"|"S"|"2004"|"7"|"0"||"1"|"COPPER"|"S"|"1954"|"10"|"0"||"1"|"IRON"|"S"|"2004"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1997"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"|"Recessed wall mounted drinking fountain. Non ADA compliant."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"5"|"0"|"Recommend providing addressable fire alarm system."|"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1996"|"7"|"0"||"1"|"S"|"2005"|"7"|"0"||"1"|"1"|"0"|"The building has accessible interior and exterior routes."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"1"|"CLASSROOMS"||"1"|"1"|"0"|"Water stains in ceiling have been painted over. Room 306 smelled musty."|"0"|"0"|"0"|"0"|"1"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"HVAC,SUMPPUMP"|"FULL"|"0"|"1"|"0"|"GOOD"||"333586.96"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/22/2010 3:15:34 PM| 421|"South Kortright CSD"|"12170204"|"Bus Garage"|"5001"|"10/20/2010"|"58200 State Highway 10"|"South Kortright"|" 13842"|"ANNUAL"|"12/29/2010"|"1939"|"8470"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"transportation maintenance facility"|"0"|"OTHER"|"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"2"|"2500"|"S"|"2006"|"20"|"0"||"1"|"WELL"|"S"|"2001"|"20"|"0"||"1"|"SITESEPT"|"S"|"2009"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"ONSITE"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"15"|"0"||"1"|"CONCRETE"|"S"|"2009"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"10"|"0"|"existing lockers reused"|"1"|"S"|"S"|"2009"|"5"|"15000"|"1939 interior wood doors need replacement"|"1"|"S"|"2001"|"15"|"0"|"pit stairs"|"1"|"S"|"2009"|"20"|"0"|"vehicle lift"|"1"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"10"|"15000"|"t12 lamps in old building need replacement"|"1"|"1"|"S"|"2009"|"8"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"0"|"0"||"1"|"COMMON"|"S"|"2009"|"15"|"0"||"1"|"COMMON"|"S"|"2009"|"15"|"0"||"0"||"S"|||||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"1"|"S"|"2009"|"8"|"15000"|"1939 slab is pitted and should be resurfaced"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"5000"|"minor pointing"|"0"|||||"0"|"removed in 2009"|"1"|"MASONRY"|"S"|"1939"|"10"|"0"||"S"|"S"|"0"|"1"|"2009"|"5"|"12000"|"1939 doors should be replaced"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"2009"|"5"|"25000"|"1939 building windows need replacement"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"8"|"0"|"1996 roof replacement plan with warranty"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2009"|"20"|"0"||"1"|"IRON"|"S"|"2009"|"20"|"5000"|"old section bus garage floor drain vetn to roof cut off at floor - recommend reconnect to V.T.R."|"1"|"OIL"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20"|"0"|"maintenance bay hex ventilation unit is noisy"|"1"|"S"|"2009"|"2"|"10000"|"old section bus garage existing unit heaters piping very corroded recommend replacement"|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"1"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"HVAC"||"0"|"1"||"GOOD"||"125000"|"S"|"1"|"SWBR Architects"|"4914 West Genesee Street"|"315 488-5635"|"fkoenig@swbr.com"|"Frederick Koenig"|"031617"|"I accept"|12/22/2010 3:22:40 PM| 423|"BOCES Albany-Schoh-Schen"|"01900000"|"Building A"|"0007"|"7/19/2010"|"1015 Watervliet-Shaker Road"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1973"|"25660"|"1"|"1"|"1"|"DISTRICT"|"INSTRUCT"||"132"|"9,10,11,12"|"0"|"1"|"0"|"132"|"0"|"0"|||"0"|"0"|"ADMIN,SPECED,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with water service"|"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with sanitary service"|"1"|"S"|"1999"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with gas service"|"1"|"UTIL"|"BELOW"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with electrical service"|"1"|"S"|"1973"|"15"|"0"|"Roof drains and catch basins are piped underground to the municipal system there are no current storm drainage problems"|"1"|"S"|"1973"|"15"|"0"|"A small area along Vly Road drains to a swale and to the open drainage along the street"|"1"|"S"|"2010"|"15"|"0"|"parking lots drain to catch basins. BOCES has been rebuilding catch basin tops as part of regular maintenance program"|"0"||||"0"||"0"|"MUNI"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"53000"|"Paving is beginning to show signs of age Replacement may be needed within 5 years"|"1"|"ASPHALT"|"S"|"1998"|"10"|"18000"|"Consider replacement of asphalt walks when road parking paving is completed"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"On the exterior of the building the concrete block veneer continues below grade and the foundation is not visible"|"0"||||"0"||"1"|"S"|"2004"|"15"|"0"|"Gypsum wallboard on metal stud framing"|"1"|"S"|"1990"|"15"|"0"|"ceilings replaced as needed 2x4 suspended ceilings"|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1973"|"4"|"43000"|"Electrical branch circuit panel replacement needed"|"1"|"S"|"1997"|"10"|"11000"|"Corridors updated to T8s in 1997 All other areas are T12s consider updating "|"1"|"1"|"S"|"2007"|"4"|"33000"|"Intercom was relocated from former building and is older than Building A Telephone VOIP and data systems available throughout building to supplement intercom"|"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"|"Generally located in Office areas"|"1"|"INSTRUCT"|"S"|"1995"|"15"|"0"|"Areas of VCT over VCT exist"|"1"|"INSTRUCT,COMMON"|"S"|"1973"|"15"|"0"|"Terrazzo corridors"|"0"|||||"0"||"OTHER"|"Floors are unreinforced slab on grade"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"No structural floor systems Floors are unreinforced slab on grade"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"0"|"Expansion joints have been recaulked Other caulking should be removed and replaced and tested for PCBs and Asbestos Lintels should be painted"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"|"BOCES has been replacing doors on a yearly basis as a maintenance project"|"1"|"S"|"2004"|"15"|"0"|"Exterior covered ramp connecting buildings A & B"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1973"|"4"|"69000"|"Each shop has door to the exterior Windows are in good condition though not as thermally efficient as new windows Some sills are loose and need repair Paint lintels Consider phased window replacement in next 5 years"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"0"|"Roofing is at end of useful life Roofing replacement is under contract and scheduled for 2011"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"10"|"0"|"Repairing various minor leaks as the occur Original system"|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as the occur Original system"|"1"|"ELECTRIC"|"S"|"1973"|"4"|"0"|"Replacing heaters as they fail Original heater in this building"|"1"|"S"|"1973"|"10"|"0"|"Original fixtures"|"1"|"CV"|"1"|"FURNACE,OTHER"|"Unit ventilation"|"S"|"1999"|"10"|"0"|"Mixture of new and original equipment"|"1"|"S"|"1973"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"|"Mixture of new and original equipment"|"1"|"S"|"1999"|"4"|"17000"|"Roof top units. Restroom fans need replacement"|"0"||||"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop curbs connecting ductwork replaced in 1999 still some original equipment"|"1"|"S"|"1999"|"4"|"26000"|"Upgrade existing controls"|"1"|"S"|"2009"|"15"|"0"|"Fire alarm panel located in Building C"|"1"|"S"|"1973"|"4"|"27000"|"Detectors are heat detectors. Upgrade to addressable smoke detectors"|"0"||||"0"||"1"|"S"|"1997"|"15"|"6000"|"Additional unit emergency lights needed in hallways"|"0"||||"0"||"1"|"1"|"0"|"Consider gang toilets Not budgeted Need to identify available space Possibly a lift at Building C BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance BOCES is implementing required improvements"|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"No general purpose classrooms comments are for shop type areas"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"303000"|"S"|"0"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/22/2010 3:24:21 PM| 424|"Clarence CSD"|"14080106"|"CLARENCE HIGH SCHOOL"|"0004"|"11/05/2010"|"9625 MAIN STREET"|"CLARENCE "|" 14031"|"ANNUAL"|"07/01/2011"|"1951"|"344066"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"1650"|"9,10,11,12"|"0"|"1"|"1"|"1564"|"0"|"86"|"CAFE,LIB"||"64"|"57104"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,MUSIC,SCIENCELAB,SPECED,POOL,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"5"|"15,000"|"ADD BACKFLOW PREVENTOR IN FIRE PROTECTION SERVICE TO MEET CODE."|"1"|"MUN_UTILIT"|"E"|"1996"|"25"|"0"||"1"|"S"|"1996"|"5"|"80,000"|"UPGRADE METER, ADD SEPERATE GAS LINE FOR EMERGENCY GENERATOR."|"1"|"UTIL"|"BELOW"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1996"|"2"|"1,093,000"|"REPLACE REAR PARKING LOT AND ACCESS ROAD."|"0"|"CONCRETE"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"E"|"2010"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"30"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"U"|"1996"|"2"|"23,000"|"REPLACE LOCKERS IN CORRIDOR ADJACENT TO LECTURE HALL"|"1"|"S"|"S"|"1996"|"20"|"0"||"1"|"U"|"1996"|"1"|"25,000"|"REPLACE STAIR TREADS AND RISERS AT MISC. STAIRS."|"1"|"U"|"1952"|"3"|"80,000"|"REPLACE ELEVATOR TO CONFORM TO ADA REQUIREMENTS."|"1"|"0"|"U"|"1996"|"1"|"600,000"|"REPLACE ALL ORIGINAL PANELBOARDS AND SWITCHGEAR, OLDER RECEPTACLES IN VARIOUS AREAS."|"1"|"S"|"1996"|"5"|"340,000"|"REPLACE REMAINGING T12 FLUORESCENT, INCANDESCENT AND INTERIOR HID LUMINAIRES."|"1"|"1"|"S"|"1996"|"5"|"1,025,000"|"REPLACE CLOCK SYSTEM, REPLACE OLDER DATA CANLING, REPLACE OLDER P/A SPEAKERS, NEW AUD. SOUND SYSTEM."|"1"|"S"|"1996"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"1996"|"1"|"201,000"|"REPLACE CARPETING WITH NEW VCT IN CLASSROOMS."|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"10"|"0"||"1"|"COMMON"|"S"|"1996"|"15"|"0"||"1"|"COMMON"|"S"|"1996"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"1"|"0"|"0"|"0"||"U"|"1996"|"1"|"282,000"|"MISC. MASONRY RESTORATION (REPOINTING, REBUILDINGBRICK WALLS ETC.)"|"1"|"MASONRY"|"S"|"1994"|"30"|"50,000"|"LOWER CHIMNEY."|"0"|"MASONRY"|"S"|"1952"|"20"|"0"||"U"|"S"|"1"|"1"|"1996"|"2"|"30,000"|"REPLACE MISC. EXTERIOR DOORS."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"25"|"0"||"1"|"PLASTIC"|"S"|"1996"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1996"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1996"|"5"|"50,000"|"REMOVE EXISTING LAUNDRY PIT, REPLACE DEGRADED SECTIONS OF SANITARY PIPING."|"1"|"NAT_GAS"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"5"|"155,000"|"REPLACE ORIGINAL HOME EC. SINKS AND OTHER MISC. ORIGINAL FIXTURES. "|"0"||"1"|"BOILERWATE"||"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"2"|"130,000"|"AIR CONDITION INTERIOR ROOMS AND I.T."|"1"|"S"|"1996"|"2"|"220,000"|"REPLACE ORIGINAL EXHAUST FANS / RELIEF VENTS, DUST COLLECTION SYSTEM FOR TECHNOLOGY AND BASEMENT ROOM VENTILATION SYSTEM."|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"5"|"200,000"|"UPGRADE FIRE ALARM SYSTEM TO CURRENT CODE REQUIREMENTS."|"1"|"S"|"1996"|"1"|"60,000"|"REPLACE 10+/- YEAR OLD SMOKE HEADS ONLY."|"1"|"S"|"1996"|"1996"|"30,000"|"INSTALL NEW FIRE PROTECTION MAIN FROM NORTHWEST CORNER OF NUILDING TO SPRINKLE RIFLE RANGE."|"1"|"U"|"1996"|"1"|"130,000"|"UPGRADE EMERGENCY LIGHTING IN VARIOUS AREAS."|"1"|"U"|"1996"|"1"|"160,000"|"SEGREGATE STANDBY AND EMERGENCY LOADS."|"1"|"1"|"829,000"|"PROVIDE HANDICAP ACCESSIBILITY TO THE RIFLE RANGE, REPLACE EXTERIOR BLEACHERS (INCLUDING ADA ACCESSIBILITY) INSTALL LEVER HANDLES ON MISC. DOORS."|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"ACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"0"|"0"|"1"|"FAIR"||"5,200,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesarchitect.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/22/2010 3:25:20 PM| 428|"Yorkshire-Pioneer CSD"|"04350106"|"PIONEER HIGH SCHOOL"|"0014"|"11/12/2010"|"COUNTY LINE ROAD"|"YORKSHIRE"|" 14173"|"ANNUAL"|"07/01/2011"|"1969"|"220,493"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"753"|"9,10,11,12"|"0"|"1"|"1"|"753"|"0"|"0"|||"49"|"41,482"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"2000"|"U"|"1991"|"5"|"100,000"|"REMOVE AND REPLACE TANK"|"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"5"|"700,000"|"REPLACE PRIMARY ELECTRICAL SERVICE, REPLACE ORIGINAL SITE LIGHTING POLES REPLACE TENNIS COURT LIGHTING FIXTURES."|"0"||||"0"||"1"|"S"|"1969"|"10"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"1969"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2008"|"25"|"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2008"|"1"|"676,000"|"REPLACE ACCESS TO MIDDLE SCHOOL, SOUTH LOT AND ACCESS ROADS TO HIGH SCHOOL LOT."|"0"|"CONCRETE"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"15"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1991"|"30"|"0"||"1"|"S"|"1969"|"30"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"U"|"1969"|"2"|"440,000"|"REPLACE GYMNASIUM, JV FOOTBALL AND SOCCER LOCKER ROOM LOCKERS. REPLACE ALL CORRIDOR LOCKERS."|"1"|"S"|"S"|"2008"|"15"|"0"||"1"|"S"|"1969"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2008"|"5"|"50,000"|"REPLACE REMAINING ORIGINAL ELECTRICAL DEVICES/EQUIPMENT."|"1"|"S"|"2008"|"5"|"275,000"|"REPLACE/UPGRADE AUDITORIUM, GYMNASIUM AND POOL LIGHTING. LIGHTING REPLACE VARIOUS OLDER LIGHTS."|"1"|"1"|"S"|"2008"|"5"|"500,000"|"REPLACE CLOCK SYSTEMAND OLD PUBLIC ADDRESS SPEAKERS. REPLACE CAT-V DATA CABLING."|"1"|"U"|"1989"|"5"|"275,000"|"REPLACE FILTER SYSTEM."|"1"|"COMMON"|"S"|"2008"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"1991"|"2"|"32,000"|"REPLACE VAT IN CLASSROOMS A-126, B-153, B-155 AND E-120."|"1"|"COMMON"|"U"|"2008"|"1"|"30,000"|"REPLACE CONCRETE FLOOR IN METAL SHOP E-117."|"1"|"INSTRUCT,COMMON"|"U"|"1969"|"2"|"5,000"|"REFINISH WOOD FLOOR IN WOOD SHOP."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1991"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1991"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1997"|"2"|"104,000"|"REPLACE INTRUSION DETECTION SECURITY SYSTEM, REPLACE MISCELLANEOUS EXTERIOR DOORS."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"AREA ABOVE POOL HAS UPLIFTED AND NEEDS REPAIR."|"S"|"2005"|"20"|"0"||"1"|"PLASTIC"|"S"|"2000"|"20"|"0"||"1"|"IRON,COPPER"|"U"|"2008"|"5"|"200,000"|"ADD WATER TREATMENT SYSTEM REPLACE OLD VALES AND DETERIORATED PIPING."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"5"|"50,000"|"REPLACE SUMP PUMPS AND PIPING."|"1"|"ELECTRIC"|"S"|"2008"|"15"|"0"||"1"|"U"|"2008"|"5"|"250,000"|"REPLACE ORIGINAL FIXTURES AND OLD SHOWER ASSEMBLIES."|"0"||"1"|"BOILERWATE,OTHER"|"ELECTRIC BOOSTER"|"E"|"2008"|"15"|"0"||"1"|"S"|"1969"|"20"|"0"|"MUNICIPAL ELECTRICAL SYSTEM."|"1"|"S"|"2008"|"15"|"2,300,000"|"REPLACE ORIGINAL CLASSROOM HEAT PUMPS (1996), AIR CONDITIONING UNITS AND POOL AIR HANDLING UNITS."|"1"|"S"|"2008"|"5"|"385,000"|"ADD AUDITORIUM VENTILATION, LOCKER ROOM VENTILATION AND MISCELLANEOUS EXHAUST SYSTEMS."|"1"|"U"|"2008"|"5"|"265,000"|"REPLACE HEAT PUMPS SERVICE MAINS, 2 PUMPS, MISCELLANEOUS ORIGINAL RADIATORS."|"1"|"S"|"2008"|"5"|"80,000"|"REPLACE AUDITORIUM CEILING DIFFUSERS INTERNALLY CLEAN MISCELLANEOUS DUCTWORK."|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"17"|"0"||"1"|"S"|"2008"|"2"|"10,000"|"REPLACE OLDER HEAT DETECTOR HEADS."|"0"||||"0"||"1"|"S"|"2008"|"23"|"0"||"1"|"S"|"2008"|"28"|"0"||"1"|"1"|"30,000"|"PROVIDE HANDICAP ACCESSIBILITY FOR THE JV FOOTBALL/SOCCER LOCKER ROOMS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"0"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"||"0"|"1"|"GOOD"||"7,400,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES ARCHITECTS"|"5757 MAIN STREET, WILLIAMSVILLE, NEW YORK 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/22/2010 3:48:48 PM| 429|"BOCES Western Suffolk"|"58930000"|"James E. Allen Jr./Sr. High School"|"0016"|"07/16/2010"|"35 CARMAN RD "|"MELVILLE "|" 11746"|"ANNUAL"|"05/01/2011"|"1973"|"78090"|"1"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"311"|"6,7,8,9"|"0"|"1"|"0"|"311"|"0"|"0"|||"49"|"34300"|"ADMIN,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,TECHSHOP"||"1"|"0"|"0"|"1"|"20000"|"S"|"1973"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"2007"|"17"|"0"||"1"|"SITESEPT"|"S"|"1973"|"17"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1973"|"19"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2007"|"1"|"400,000"|"Replace pavement at North parking area and South road to parking."|"1"|"CONCRETE"|"U"|"2007"|"1"|"50,000"|"Repair sidewalks at front and back of school."|"1"|"S"|"2004"|"9"|"0"||"1"|"S"|"2004"|"6"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"22"|"0"||"1"|"S"|"1973"|"11"|"0"||"1"|"S"|"1973"|"1"|"20,000"|"Repair cracks in several locations."|"1"|"U"|"2003"|"1"|"170,000"|"Asbestos material applied to gyp. board is being abated."|"1"|"S"|"2004"|"4"|"0"||"0"|"S"|"S"|"2005"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"13"|"0"||"1"|"U"|"1973"|"1"|"150,000"|"Being replaced when asbestos abatement is performed."|"1"|"1"|"S"|"1999"|"2"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2008"|"1"|"15,000"|"Replace vinyl tile in CRs#307-308 and Nurse's Office."|"1"|"COMMON"|"S"|"2008"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"17"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"1973"|"22"|"0"||"1"|"METAL"|"S"|"2005"|"12"|"0"||"0"|||||"0"||"U"|"U"|"0"|"1"|"2008"|"1"|"21,000"|"Replace doors as required."|"1"|"U"|"1995"|"1"|"15,500"|"Replace HC Ramp at Main Entrance. "|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2002"|"1"|"650,000"|"Replace with energy efficient windows."|"METONMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"1"||"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1973"|"7"|"0"||"1"|"IRON"|"S"|"1973"|"7"|"0"||"1"|"OIL"|"S"|"1973"|"2"|"0"||"1"|"S"|"1973"|"4"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2010"|"7"|"0"|"New Nesbit Units installed in Attic."|"1"|"S"|"1973"|"7"|"0"||"1"|"S"|"2010"|"17"|"0"||"0"|"U"|"1973"|"1"|"375,000"|"Air handlers need replacement."|"1"|"S"|"1973"|"7"|"0"||"1"|"S"|"1973"|"1"|"200,000"|"Replace ducts as required for new air handlers."|"1"|"S"|"1973"|"1"|"0"|"New controls with new units."|"1"|"S"|"2006"|"7"|"0"||"1"|"S"|"1973"|"2"|"0"||"1"|"S"|"2006"|"2006"|"0"||"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"1"|"0"|"0"|"0"|"1"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"POOR"||"2,066,500"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/22/2010 4:07:35 PM| 430|"Valley Stream 30 UFSD"|"28023002"|"Washington Avenue"|"0007"|"08/25/2010"|"Washington Avenue"|"Valley Stream"|" 11580"|"ANNUAL"|"05/01/2011"|"1956"|"5219"|"1"|"1"|"1"|"DISTRICT"|"INSTRUCT"||"58"|"K"|"0"|"0"|"0"|"58"|"0"|"0"|||"3"|"2360"|"HLTHSUITE,MULTIPURPO"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2002"|"10"|"0"||"1"|"CONCRETE"|"E"|"2002"|"10"|"0"||"1"|"E"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"E"|"E"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"E"|"2003"|"20"|"0"||"1"|"COMMON"|"S"|"1998"|"15"|"0"|"Ceramic tile in toilets only"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"20"|"0"||"1"|"METAL"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2003"|"20"|"0"||"1"|"E"|"2003"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"15"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"|"Rof top units"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"0"|"E"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/22/2010 4:12:57 PM| 431|"BOCES Albany-Schoh-Schen"|"01900000"|"Building B"|"0008"|"7/19/2010"|"1015 Watervliet-Shaker Road"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1973"|"23260"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"132"|"9,10,11,12"|"0"|"0"|"0"|"132"|"0"|"0"|||"0"|"0"|"COMPROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with water service Water service enters at Building A for the whole complex"|"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with sanitary service Each building has its own drain and house trap to a common line under the driveway Two grease traps at Building B cleaned annually"|"1"|"S"|"1999"|"15"|"0"|"Service is underground and not visible but no problems have been encounter with gas service Gas service enters at Building B to serve A and B Each entrance is metered"|"1"|"UTIL"|"BELOW"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with electrical service Utility supplies Building C Buildings A B D E and F are supplied radially from C"|"1"|"S"|"1973"|"15"|"0"|"Roof drains and catch basins are piped underground to the municipal system. There are no current storm drainage problems"|"1"|"S"|"1973"|"15"|"0"|"A small area along Vly Road drains to a swale and to the open drainage along the street"|"1"|"S"|"2010"|"15"|"0"|"Parking lots drain to catch basins BOCES has been rebuilding catch basin tops as part of regular maintenance program"|"0"||||"0"||"0"|"MUNI"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"29000"|"Paving is beginning to show signs of age Replacement may be needed within 5 years"|"1"|"ASPHALT"|"S"|"1998"|"10"|"42000"|"Consider replacement of asphalt walks when road parking paving is completed Asphalt walks are beginning to show signs of age Replacement may be needed within 5 years"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"On the exterior of the building the concrete block veneer continues below grade and the foundation is not visible"|"0"||||"0"||"1"|"S"|"2004"|"15"|"0"|"Gypsum wall board on metal stud framing"|"1"|"S"|"1990"|"15"|"0"|"Ceilings replaced as needed 2x4 Suspended ceilings"|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1973"|"4"|"39000"|"Electrical branch circuit panel replacement needed"|"1"|"S"|"1997"|"10"|"10000"|"Corridors updated to T8s in 1997 All other areas are T12s Consider updating"|"1"|"1"|"S"|"2005"|"4"|"29000"|"Repair parts difficult to obtain Intercom was relocated from former building and is older than Building A"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1995"|"15"|"0"|"Areas of VCT over VCT exist"|"1"|"COMMON"|"S"|"1973"|"15"|"0"|"Terrazzo corridors"|"0"|||||"0"||"OTHER"|"Floors are unreinforced slab on grade"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"Floors are unreinforced slab on grade No structural floor systems"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"0"|"Expansion joints have been recaulked Other caulking should be removed and replaced and tested for PCBs and asbestos Lintels should be painted"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"|"BOCES has been replacing doors on a yearly basis as a maintenance project"|"1"|"S"|"2004"|"15"|"0"|"Exterior covered ramp connecting buildings Also exterior steps Ramp between A and B also B to C Steps to parking lot Recommend painting handrails"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1973"|"4"|"60000"|"Each shop has door to the exterior Windows are in good condition though not as thermally efficient as new windows Some sills are loose and need repair Paint lintels Consider phased window replacement in next 5 years"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"527000"|"Roofing is at end of useful life Planned for replacement in 2011 2012"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"15"|"0"|"Repairing minor leaks as they occur Original system"|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1973"|"15"|"0"|"Repairing minor leaks as they occur"|"1"|"ELECTRIC"|"S"|"1973"|"4"|"9000"|"Replacing heaters as they fail original heater in this building"|"1"|"S"|"1973"|"15"|"0"|"Original fixtures"|"1"|"CV"|"1"|"FURNACE,OTHER"|"Unit ventilation"|"S"|"1999"|"15"|"0"|"Mixture of new and original equipment"|"1"|"S"|"1973"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop Units Mixture of new and original equipment"|"1"|"S"|"1999"|"4"|"17000"|"Rooftop Units Restroom fans need replacement"|"0"||||"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop and curbs and connecting ductwork replaced in 1999 Some original equipment remains"|"1"|"S"|"1999"|"15"|"26000"|"original equipment upgrade"|"1"|"S"|"2009"|"15"|"0"|"Fire alarm panel located in Building C"|"1"|"S"|"1973"|"4"|"27000"|"Detectors are heat detectors upgrade to addressable smoke detectors"|"0"||||"0"||"1"|"S"|"1997"|"15"|"6000"|"Additional unit emergency lights needed in hallways"|"0"||||"0"||"1"|"1"|"0"|"Consider gang toilets Not budgeted Need to identify available space BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance BOCES is implementing required improvements"|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"No General Purpose Classrooms comments are for shop type areas"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Most spaces are Vocational Classrooms ie shops"|"821000"|"S"|"1"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/22/2010 4:28:53 PM| 432|"Clarence CSD"|"14080106"|"CLARENCE MIDDLE SCHOOL"|"0008"|"11/08/2010"|"10150 GREINER ROAD"|"CLARENCE"|" 14031"|"ANNUAL"|"7/1/11"|"1966"|"259,396"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"1260"|"6,7,8"|"0"|"1"|"0"|"1151"|"0"|"109"|"CAFE,LIB"||"59"|"51,517"|"ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,SCIENCELAB,SPECED,POOL,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"5"|"50,000"|"REPLACE ORIGNIAL SITE LIGHTING IN FRONT PARKING LOT."|"0"||||"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"1"|"S"|"2006"|"1"|"10,000"|"CLEAN EXISTING RETENTION POND."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2007"|"2"|"256,000"|"REPLACE FRONT PARKING LOT AND BUS LOOP."|"1"|"CONCRETE"|"E"|"2007"|"20"|"0"||"0"||||"0"||"1"|"E"|"2007"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2007"|"30"|"0"||"1"|"S"|"2007"|"30"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"S"|"S"|"2007"|"15"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"1"|"S"|"2007"|"3"|"95,000"|"REPLACE REMAINING ORIGINAL PANELBOARDS AND TRANSFORMERS. REPLACE LOCKER ROOM HAIR DRYERS."|"1"|"S"|"2007"|"1"|"170,000"|"REPLACE REMAINING T12 FLUORESCENT, INCANDESCENT AND INTERIOR HID LUMINARIES."|"1"|"1"|"S"|"2007"|"5"|"160,000"|"REPLACE OLD DATA CABLING, COMPLETE UPGRADE OF PHONE SYSTEM."|"1"|"U"|"1994"|"1"|"90,000"|"SAND FILTRATION SYSTEM IS FAILING, REPLACE SYSTEM AND PIPING. CLEAN AND FLUSH PIPING."|"1"|"INSTRUCT,COMMON"|"U"|"2007"|"1"|"119,000"|"REPLACE CARPET IN 1991 ADDITION AND MEDIA CENTER."|"1"|"INSTRUCT,COMMON"|"E"|"2007"|"15"|"0"||"1"|"COMMON"|"S"|"2007"|"20"|"0"||"1"|"COMMON"|"U"|"2007"|"2"|"77,000"|"REPLACE WOOD FLOORIN MAIN GYM."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2007"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"30"|"0"||"1"|"MASONRY"|"S"|"2007"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2007"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2007"|"1"|"169,000"|"REPLACE WINDOWS IN ORIGINAL BUILDING."|"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"25"|"0"||"1"|"PLASTIC"|"S"|"2009"|"15"|"0"||"1"|"COPPER"|"S"|"1994"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2005"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2005"|"30"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"2005"|"2"|"45,000"|"PROVIDE A/C FOR 3 SERVER ROOMS."|"1"|"S"|"2005"|"2"|"12,000"|"VENTILATE TRANSFORMER ROOM."|"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2007"|"17"|"0"||"1"|"S"|"2007"|"7"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2007"|"1"|"2,000"|"REPLACE REMAINING INCANDESCENT EXIT SIGNS."|"1"|"S"|"2007"|"10"|"0"|"10 YEARS FOR STANDBY GENERATOR. 27 YEARS FOR EMERGENCY GENERATOR."|"1"|"1"|"17,000"|"PROVIDE ADA ACCESSIBILTY IN THE 1991 ADDITION TOILET ROOMS / SOUTH GYM LOCKER ROOM TOILET AREAS AND INSTALL LEVER LOCKSETS AT MIS. DOORS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"1,300,000"|"E"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville NY 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I accept"|12/22/2010 4:30:50 PM| 433|"Lockport City SD"|"40040001"|"Charlotte Cross"|"0007"|"06/30/2010"|"319 WEST AVENUE "|"LOCKPORT "|" 14094"|"ANNUAL"|"12/01/2010"|"1929"|"39213"|"3"|"2"|"0"|"PART"|"INSTRUCT,DIST_ADMIN"||"75"|"9,10,11,12"|"0"|"1"|"0"|"75"|"0"|"0"|||"13"|"8854"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1929"|"10"|"0"|"No backflow prevention device installed."|"1"|"MUN_UTILIT"|"S"|"1929"|"15"|"0"||"1"|"S"|"1929"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2009"|"7"|"0"||"1"|"S"|"1929"|"10"|"0"||"0"||||"0"||"1"|"S"|"1929"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1998"|"3"|"186000"|"Staff reported pooling of water due to poor grading and lack of catch basins."|"1"|"CONCRETE"|"S"|"2000"|"15"|"0"||"1"|"S"|"1958"|"5"|"0"|"Some rusting at slide stairs and swing chains."|"0"||||"0"|||"RECONCRETE"|"1"|"0"|"1"|"0"|"0"|"0"|"U"|"1929"|"3"|"592"|"Evidence of cracking. Recommend review by structural engineer."|"0"||||"0"||"1"|"S"|"1958"|"15"|"0"|"Recommend patch and repair of crack in wall in 1958 stairwell."|"1"|"S"|"2009"|"10"|"0"|"Suspended perforated acoustical tile. Water stains present in 4 areas of ceiling. Recommend replacing or repainting approx. 150 sf due to water stains."|"1"|"U"|"2004"|"3"|"4012.35"|"Very rusted interiors and latches do not work."|"1"|"S"|"S"|"2000"|"10"|"0"||"1"|"S"|"1958"|"10"|"0"|"Handrails do not extend past trend."|"1"|"S"|"2001"|"10"|"0"|"Some rusting at bottom door and on left platform."|"1"|"1"|"U"|"2000"|"3"|"3200"|"Old fuse panel board needs to be replaced."|"1"|"U"|"2000"|"3"|"1000"|"Existing t12 2 lamp lighting fixtures should be replaced with new energy efficient t8 lamp lighting fixtures."|"1"|"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"7"|"0"|"Very worn with stains, pulls, and wear marks."|"1"|"COMMON"|"S"|"1958"|"10"|"0"|"General wearing and scratches"|"1"|"COMMON"|"S"|"1958"|"10"|"0"|"Some areas of chipped tiles and floor surface is dirty."|"1"|"INSTRUCT"|"S"|"1929"|"15"|"0"||"SLABGRADE,OTHER"|"Cats in place concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1929"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1929"|"10"|"0"|"Some repainting needed at rear stair."|"1"|"MASONRY"|"S"|"1929"|"10"|"0"|"Recommend minor repointing and repair step cracking."|"1"|"MASONRY"|"S"|"1929"|"15"|"0"||"U"|"U"|"0"|"1"|"2008"|"3"|"9551.64"|"Wood doors in poor condition. Need to be replaced."|"1"|"S"|"1929"|"5"|"0"|"Stairs are full of debris and may pose a safety hazard for the emergency exit. Have maintenence staff clean out."|"0"|||||"0"||"1"|"ALUMINUM,WOOD"|"S"|"Y"|"1995"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2008"|"20"|"0"||"0"|||||"0"||"1"|"GALVANIZED"|"S"|"1929"|"5"|"0"||"1"|"GALVANIZED"|"S"|"1929"|"5"|"0"||"1"|"NAT_GAS"|"S"|"2006"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"|"Many fixtures non ADA compliant."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1929"|"3"|"0"|"Kewanee fire tube, reached end of useful life power flame burners"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"1929"|"5"|"0"||"1"|"S"|"1929"|"5"|"0"|"Recommend replacement or cleaning."|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"E"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"2000"|"7"|"0"||"1"|"1"|"0"|"The only accessible floor is the first floor with the assistance of a lift."|"GOOD"||"FAIR"||"1"|"1"|"FAIR"|"Gym echoes throughout first floor."|"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"1"|"OTHER"|"basement"|"1"|"1"|||"0"|"0"|"1"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"|"Classrooms in basement do not have ventilation."|"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"HVAC,SUMPPUMP"|"WARMING"|"0"|"1"|"0"|"GOOD"||"204355.99"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/22/2010 4:33:50 PM| 434|"Hauppauge UFSD"|"58050603"|"Pines Elementary"|"0006"|"8/17/10"|"22 Holly Drive"|"Smithtown"|" 11787"|"ANNUAL"|"5/1/11"|"1965"|"86,037"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"620"|"K,1,2,3,4,5"|"0"|"1"|"1"|"620"|"0"|"0"|||"41"|"25,130"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,TEACHRSRC"||"1"|"0"|"0"|"1"|"8000"|"S"|"1991"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"15"|"0"||"1"|"SITESEPT"|"S"|"1965"|"15"|"0"||"1"|"S"|"2004"|"15"|"8,000"|"Recommend all roof top gas piping be painted safety yellow"|"1"|"UTIL"|"BELOW"|"S"|"2005"|"15"|"0"|"Upgrade to service as part of building addition"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"10"|"784,200"|"Recon at bldg rear, main & north parking lots & bus loop, additional entrance/exit, additional parking spaces, reduce heat island effect along south elevation"|"1"|"CONCRETE"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"80,000"|"Replace existing pea gravel from areas which currently do not have accessible playground surface with ADA accessible material - approximately 275' x 65'"|"1"|"S"|"2004"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1965"|"25"|"0"||"1"|"S"|"1965"|"25"|"12,000"|"Misc fire stopping, remove existing corridor glazing & replace with fire rated glazing or metal stud framing & sheetrock, replace existing corridor doors with 20 min rated & lever hardware"|"1"|"S"|"1965"|"25"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"||"1"|"S"|"S"|"2003"|"10"|"208,500"|"Replace original doorknobs with lever type hardware, magnetic hold opens,B label doors where required, replace remaining original doors, C label doors where required "|"1"|"S"|"1965"|"20"|"0"||"1"|"U"|"1965"|"2"|"367,900"|"Recommend to install a custom size2,000 lb 4-stop elevator"|"1"|"1"|"S"|"1965"|"10"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"11,000"|"Carpet needs replacement in Guidance & AP Office, carpet over VAT"|"1"|"INSTRUCT"|"E"|"2007"|"12"|"164,000"|"On going VAT replacement plan - recommend replacement of remaining VAT"|"1"|"COMMON"|"E"|"1965"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2005"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1965"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1965"|"25"|"31,000"|"Miscellaneous masonry repair needed - lintels at cafeteria, as well as other locations"|"1"|"MASONRY"|"S"|"1965"|"5"|"14,000"|"Chimney cap needs to be replaced. Repointing required"|"0"|||||"0"||"S"|"S"|"1"|"1"|"2004"|"15"|"42,000"|"3 pairs of exterior doors & 3 single doors have not yet been replaced. Replace with new 2 x 6 aluminum frames & FRP doors"|"1"|"S"|"2005"|"15"|"56,000"|"Recommend reconstruction of main steps to upper field & instlalation of an additional handrail down the middle of the stairway."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2002"|"15"|"100,000"|"Rescue window in several rooms (sliders) difficult to open. Install missing rescue windows. Replace existing glass block in Gym & Cafeteria"|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"20"|"0"|"Active leaks around skylights need to be investigated. Roof under warranty."|"1"|"PLASTIC"|"E"|"2007"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"15"|"0"||"1"|"IRON"|"S"|"1965"|"15"|"17,000"|"Replace 2 existing rusted waste lines at Storage Room ceiling"|"1"|"OIL"|"S"|"1970"|"10"|"0"|"Hot water coil & hot water storage tank only"|"1"|"S"|"2005"|"15"|"134,000"|"Replace original sink/bubblers and replace with 1 per grade level being handicapped accessible"|"0"||"1"|"BOILERWATE"||"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2009"|"15"|"122,000"|"Int & ext non-student occupied spaces shall be mechaniccally ventilated providing a ventilation rate of 20 CFM per person & int spaces of pupil occ shall be provided with equip for mech cooling when provided by outdoor air cannot maintain 74 F"|"1"|"S"|"1965"|"4"|"596,000"|"Unit ventilator replacement - remove 36 Nesbitt hot water unit ventilators & install new Magic Aire or equal. Replace 4 hot water fan coil units in office areas"|"1"|"S"|"1965"|"15"|"32,600"|"Boiler Room ventilation upgrade - increase ventilation & combustion air in Boiler Room to comply with current standards"|"1"|"S"|"1965"|"5"|"225,000"|"Recommend that a new 3-way valve be installed & connected to the control system - upgrade controls to Johnson DDC when unit vents are changed."|"1"|"S"|"2004"|"10"|"0"|"Upgraded as part of building addition"|"1"|"S"|"2004"|"10"|"0"|"Upgraded as part of building addition"|"1"|"E"|"1965"|"1965"|"0"||"1"|"E"|"2009"|"15"|"0"||"0"||||"0"||"0"|"1"|"5600"|"Automatic doors contorls, accessible route to all facilities, elements, fields, etc."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"||"GOOD"||"3,020,800"|"U"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson, NY"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/22/2010 4:33:58 PM| 437|"BOCES Western Suffolk"|"58930000"|"L.A. Wilson Tech.-Aviation Facility"|"0052"|"07/19/2010"|"7200 REPUBLIC AIRPORT "|"FARMINGDALE "|" 11735"|"ANNUAL"|"05/01/2011"|"2000"|"30000"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"190"|"10,11,12"|"0"|"1"|"0"|"190"|"0"|"0"|||"11"|"9900"|"ADMIN,COMPROOM,GUIDANCE,SCIENCELAB,TEACHRSRC,TECHSHOP,OTHER"|"Hanger"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2000"|"12"|"0"||"1"|"MUN_UTILIT"|"E"|"2000"|"12"|"0"||"1"|"E"|"2000"|"7"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2000"|"14"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"1"|"5,000"|"Repair the Front parking area."|"1"|"CONCRETE"|"S"|"2000"|"7"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"22"|"0"||"1"|"S"|"2000"|"22"|"0"||"1"|"S"|"2000"|"22"|"0"||"1"|"S"|"2000"|"2"|"0"||"1"|"S"|"2000"|"7"|"0"||"1"|"E"|"E"|"2000"|"7"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"12"|"0"||"1"|"S"|"2000"|"12"|"0"||"1"|"1"|"S"|"2000"|"2"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"7"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"7"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2000"|"22"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"22"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"2000"|"22"|"0"||"E"|"E"|"0"|"1"|"2000"|"7"|"0"||"1"|"S"|"2000"|"7"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2000"|"17"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"8"|"0"|"Finish coating recommended."|"0"|||||"0"||"0"|"COPPER"|"S"|"2000"|"12"|"0"||"1"|"IRON"|"S"|"2000"|"12"|"0"||"1"|"NAT_GAS,ELECTRIC"|"S"|"2000"|"5"|"0"||"1"|"E"|"2000"|"7"|"0"||"1"|"DD_MZ"|"1"|"OTHER"|"RTUs"|"E"|"2000"|"12"|"0"||"1"|"E"|"2000"|"12"|"0"||"0"||||"0"||"1"|"S"|"2000"|"17"|"0"||"0"||||"0"||"1"|"E"|"2000"|"17"|"0"||"1"|"S"|"2000"|"17"|"0"||"1"|"S"|"2000"|"2"|"0"||"1"|"S"|"2000"|"2"|"0"||"0"||||"0"||"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"5,000"|"E"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/22/2010 5:45:58 PM| 438|"Southwestern CSD At Jamestown"|"06020106"|"Press Box"|"7017"|"10/13/2010"|"600 Hunt Road"|"Jamestown"|"14701"|"ANNUAL"|"07/01/2011"|"1997"|"320"|"1"|"0"|"0"|"DISTRICT"|"OTHER,OTHER_ORG"|"Sporting events"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"|"N"|"Covers existing bleachers. See high school for synthetic turf field."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"E"|"1997"|"15"|"0"||"1"|"E"|"1997"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"15"|"0"|"Branch circuits only provided"|"1"|"S"|"1997"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST,OTHER"|"Raised steel sub-structure"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"15"|"0"||"STEEL,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"1997"|"10"|"0"||"1"|"S"|"1997"|"15"|"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"1997"|"5"|"0"|"Hinged plywood panels - no glass"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"|"Recommend adding emergency lights"|"0"|"0"|"0"||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"No ventilation"|"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"E"|"0"|"Trautman Associates"|"470 Franklin Street, Buffalo, nY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M Gehring"|"019087"|"I ACCEPT"|12/23/2010 8:37:33 AM| 439|"Cairo-Durham CSD"|"19030104"|"Cairo Elementary School"|"0001"|"10/16/2010"|"424 MAIN STREET "|"CAIRO "|" 12413-3118"|"ANNUAL"|"11/01/2012"|"1933"|"80,000"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"421"|"K,1,2,3,4,5"|"0"|"1"|"1"|"421"|"0"|"0"|||"35"|"26,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"15"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"5"|"280,000"|"Parking area is alligatored with ponding."|"1"|"CONCRETE"|"S"|"1998"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"5"|"22,000"|"Replace select toilet partitions."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"1"|"S"|"1996"|"5"|"82,000"|"Upgrade electrical distribution and load balancing."|"1"|"S"|"1996"|"10"|"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"5"|"210,000"|"Asbestos floor tile under failed carpeting to be abated and new carpeting."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1976"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"5"|"65,000"|"Pointing of masonry required."|"1"|"MASONRY"|"S"|"2004"|"10"|"0"||"1"|"MASONRY"|"S"|"2004"|"10"|"0"||"S"|"S"|"0"|"1"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"10"|"0"||"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"0"||"1"|"PLASTIC"|"S"|"2004"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2004"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2004"|"10"|"0"||"1"|"OIL"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2008"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"5"|"62,000"|"Upgrade temperature control system."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"1990"|"1990"|"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"$971,000"|"S"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, Ny 12061"|"518-479-4000"|"mweber@mosaicaa.com"|"Martin Weber"|"12772"|"I ACCEPT"|12/23/2010 9:13:33 AM| 441|"Southwestern CSD At Jamestown"|"06020106"|"Utility Building"|"7014"|"10/13/2010"|"600 Hunt Road"|"Jameston"|"14701"|"ANNUAL"|"07/01/2011"|"2008"|"300"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Field maintenance"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2008"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2008"|"40"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2008"|"30"|"0"||"1"|"E"|"2008"|"25"|"0"|"Add wire guards to light fixtures"|"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2008"|"48"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2008"|"40"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"40"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2008"|"12"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"33"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"0"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"No ventilation"|"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"E"|"0"|"Trautman Associates"|"470 Franklin Street, Buffalo, NY 14202"|"716-883-4400"|"rgehring@trautmanassoc.com"|"Richard M. Gehring"|"019087"|"I ACCEPT"|12/23/2010 9:18:54 AM| 447|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #5-COMPUTER GRAPHICS "|"0047"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"7488"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"42"|"9,10,11,12"|"0"|"0"|"0"|"42"|"0"|"0"|||"4"|"6052"|"COMPROOM,RSRCEROOM,OTHER"|"Server Room"|"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"2"|"0"|"Slurry seal is needed."|"1"|"CONCRETE"|"S"|"1970"|"2"|"20,000"|"Replace sidewalks."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1971"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"2"|"17,500"|"Replace outdated panels. "|"1"|"S"|"1970"|"5"|"32,000"|"Replace existing with T8 fixtures."|"1"|"1"|"S"|"2002"|"10"|"20,000"|"Provide new PA system. "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2000"|"2"|"20,000"|"Remove and replace all carpets."|"1"|"INSTRUCT,COMMON"|"U"|"1970"|"10"|"50,000"|"Remove and replace."|"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2007"|"10"|"0"||"1"|"S"|"1970"|"2"|"130,000"|"Replace concrete stair."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"2,000"|"Add two (2) new windows in northwest corner of building. "|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"1996"|"3"|"120,000"|"Seams and flashing are deteriorating. "|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"30"|"1,000"|"Replace faucet trim (2)."|"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2010"|"10"|"17,000"|"Overall, air handling and ventilation equipment is in good condition with an expected remaining useful life of 10 years. However, the Toilet Room and Dark Room exhausts are in poor condition and should be replaced as soon as possible. "|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"1"|"124,000"|"Upgrade toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"GOOD"||"489,200"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/23/2010 10:13:05 AM| 448|"BOCES Albany-Schoh-Schen"|"01900000"|"Building C"|"0009"|"7/19/2010"|"1015 Watervliet-Shaker road"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1973"|"22585"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"132"|"9,10,11,12"|"0"|"0"|"0"|"132"|"0"|"0"|||"0"|"0"|"GUIDANCE,HLTHSUITE,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with water service Water service enters at Building A for the whole complex"|"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with sanitary service Each building has its own drain and house trap to a common line under the driveway"|"1"|"S"|"1999"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with gas service Gas service enters at Building D to serve C and D Each entrance is metered."|"1"|"UTIL"|"BELOW"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with electrical service Utility supplies Building C Buildings A B D E and F are supplied radially from C"|"1"|"S"|"1973"|"15"|"0"|"Roof drains and catch basins are piped underground to the municipal system There are no current storm drainage problems"|"1"|"S"|"1973"|"15"|"0"|"A small area along Vly Road drains to a swale and to the open drainage along the street The area was dry and well drained when observed"|"1"|"S"|"2010"|"15"|"0"|"Parking lots drain to catch basins BOCES has been rebuilding catch basin tops as part of regular maintenance program"|"0"||||"0"||"0"|"MUNI"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"37000"|"Paving is beginning to show signs of age Replacement may be needed within 5 years"|"1"|"ASPHALT"|"S"|"1998"|"10"|"8000"|"Consider replacement of asphalt walks when road and parking paving is completed Asphalt walks are beginning to show signs of age Replacement may be needed within 5"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"On the exterior of the building the concrete block veneer continues below grade and the foundation is not visible There was no cracking observed in the masonry veneer that might suggest foundation issues"|"0"||||"0"||"1"|"S"|"2004"|"15"|"0"|"Gypsum wall board on metal stud framing"|"1"|"S"|"1990"|"15"|"0"|"Ceilings replaced as needed 2x4 Suspended ceilings"|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"1973"|"15"|"0"|"Corridor steps to D building"|"0"||||"0"||"1"|"1"|"S"|"1973"|"10"|"38000"|"Electrical panel replacement recommended Breakers difficult to obtain for branch circuit panels Distribution boards anticipated life is 5 years Main electrical room equipment anticipated life 10 years"|"1"|"S"|"2007"|"10"|"132000"|"Corridors updated to T8s in 1997 All other areas are T12s replaced at failure with T8s and electronic ballasts Budget is to replace remaining T12s with T8 fixtures"|"1"|"1"|"S"|"2007"|"4"|"29000"|"Telephone VOIP and data systems available throughout building to supplement intercom Intercom system needs replacement"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"15"|"0"|"Generally located in office areas and one classroom"|"1"|"INSTRUCT"|"S"|"1995"|"15"|"0"|"Areas of VCT over VCT exist"|"1"|"COMMON"|"S"|"1973"|"15"|"0"|"Terrazzo corridors"|"0"|||||"0"||"OTHER"|"Floors are unreinforced slab on grade"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"No structural floor systems Floors are unreinforced slab on grade"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"0"|"Expansion joints have been recaulked Other caulking should be removed and replaced and tested for PCBs and asbestos Lintels should be painted"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"|"BOCES has been replacing doors on a yearly basis as a maintenance project"|"1"|"S"|"2004"|"15"|"0"|"Exterior covered ramp connecting buildings Ramps between B and C and D"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1973"|"4"|"20000"|"Each shop has door to the exterior Aluminum Windows are in good condition though not as thermally efficient as new windows Some sills are loose and need repair Paint lintels. Consider phased window replacement in next 5 years"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"0"|"Roofing is at end of useful life Roofing replacement is under contract and scheduled for 2011"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"ELECTRIC"|"S"|"1973"|"4"|"9000"|"Replacing heaters as they fail"|"1"|"S"|"1973"|"15"|"0"|"Original fixtures"|"1"|"CV"|"1"|"FURNACE,OTHER"|"Unit ventilation"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"4"|"17000"|"Rooftop Units AHU satisfactory Replace rest room exhaust fans"|"0"||||"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop and curbs and connecting ductwork replaced Some original equipment remains"|"1"|"S"|"1999"|"4"|"26000"|"Original equipment Budget is to upgrade existing system"|"1"|"S"|"2009"|"15"|"0"|"New addressable panel All detectors and wiring are original"|"1"|"S"|"1973"|"4"|"27000"|"Detectors are heat detectors Upgrade to addressable smoke detectors"|"0"||||"0"||"1"|"S"|"1997"|"10"|"8000"|"Additional emergency lights recommended in hallways"|"0"||||"0"||"1"|"1"|"50000"|"Possibly a lift at steps in Building C Consider gang toilets Not budgeted Need to identify available space BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance BOCES is implementing required improvements"|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"No General Purpose Classrooms comments are for shop type areas"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Most spaces are Vocational Classrooms also referred to as shops"|"401000"|"S"|"1"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/23/2010 10:14:12 AM| 449|"Newfield CSD"|"61090104"|"Pool House"|"7006"|"08/12/2010"|"247 Main Street"|"Newfield"|" 14867"|"ANNUAL"|"09/01/2011"|"1990"|"2,016"|"1"|"0"|"0"|"DISTRICT"|"OTHER,OTHER_ORG"|"by town/school district for recreational purposes"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"20"|"0"|"Gas service appears satisfactory. Revisit in 5 years."|"1"|"UTIL"|"BELOW"|"S"|"1990"|"10"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"OTHER"|"Piped to stream adjacent to pool"|"1"|"S"|"1990"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"U"|"2000"|"5"|"0"|"N"|"Outdoor swimming pool. Refer to Item 55."|"RECONCRETE"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1990"|"30"|"279,000"|"Modify main drain and add vacuum release to comply with Virginia Graeme Baker Act. Pressure test main drain and piping. Replace pool piping if test reveals leaks. Repair and refinish pool shell to make water tight."|"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1990"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"1990"|"30"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"|"small leak in roof; no visable damage"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"5"|"35,000"|"No noticeable issues. Consider replacing roof if not under warranty. Approximately 3,000 SF."|"0"|||||"0"||"1"|"COPPER"|"S"|"1990"|"20"|"1,500"|"Install an RPZ backflow preventer in pool fill line to prevent cross contamination with the potable water system."|"1"|"IRON,PVC"|"S"|"1990"|"20"|"5,000"|"Plumbing drainage system appears satisfactory. Revisit in 5 years."|"1"|"NAT_GAS"|"S"|"1990"|"2"|"12,000"|"No problem reported. Water heaters have exceed their anticipated useful service, consider replacing."|"1"|"S"|"1990"|"10"|"0"||"0"||"0"||||||"0"|"Building has no heating system."|"0"||||"0"|"Building has no heating system."|"0"||||"0"||"0"||||"0"|"Building has no heating system."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"15,000"|"Fire alarm system does not exist, this system needs to be installed. Install fire alarm panel."|"0"||||"6,000"|"Smoke detection system does not exist, this system needs to be installed."|"0"||||"0"||"0"||||"1,500"|"Need to add (2) battery pack exit/emergency fixtures."|"0"||||"0"||"1"|"0"|"15,000"|"Lacks accessible toilet rooms. Renovate existing to add accessible toilet rooms."|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"GOOD"|"This is an open, seasonal building, only used in the summer."|"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"||"GOOD"||"481,000"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/23/2010 10:19:38 AM| 450|"Horseheads CSD"|"07090106"|"Maintenance Dept."|"3007"|"10/11/10"|"FLETCHER STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/10"|"1952"|"4770"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Maintenance Dept. offices & shop"|"0"|||"0"|"0"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1968"|"10"|"0"|"Overhead conductors from utility pole not from campus system, should be replaced with underground service"|"0"||||"0"||"0"||||"0"||"0"|"S"|"1968"|"5"|"38000"|"Ponding evident around entracne doors during heavy rain due to lack of pitch to catch basins"|"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1968"|"5"|"10000"|"Drywells should be upgraded when adjacent High School pavement is replaced"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1987"|"5"|"282000"|"Driveway serves as access to High School parking area and has been damaged by heavy bus traffic"|"1"|"CONCRETE"|"S"|"1987"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"10"|"0"||"0"|"S"|"1968"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"5"|"5000"|"Replace original service panel"|"1"|"S"|"1997"|"15"|"0"||"1"|"1"|"S"|"2002"|"5"|"5000"|"Replace obsolete phone system with voice over IP system"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1992"|"10"|"0"||"1"|"COMMON"|"S"|"1968"|"15"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"10"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Vinyl siding in some areas damaged"|"S"|"1986"|"5"|"10000"|"CMU walls at shop area should be clad with siding to prolong useful life"|"1"|"MASONRY"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1968"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"STEEL,WOODCLAD"|"S"|"NA"|"1999"|"5"|"10000"|"Remaining steel sash should be replaced"|"WOODONWOOD"|"SINGLEPLY,FORMMETAL,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"5"|"4000"|"Metal roofing should be coated to prolong useful life"|"0"|||||"0"||"1"|"COPPER"|"S"|"1968"|"20"|"0"|"Needs back-flow preventer on water service and boiler make-up"|"1"|"IRON"|"S"|"1968"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2006"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||"0"|"BOILERWATE"||"S"|"2000"|"15"|"0"||"1"|"S"|"1990"|"20"|"0"|"Exact age of boiler unknown"|"1"|"S"|"2000"|"10"|"0"|"Building has four split AC systems, exact age of units unknown"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"1"|"1"|"10000"|"Toilet room is not ADA compliant"|"GOOD"|"Building staff tries to maintain the exterior to present a positive image to the community"|"GOOD"|"Office, staff room & shop areas are well maintained"|"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"|"Interior break room should have additional outside air"|"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"374000"|"S"|"1"|"McDonald and Monterose LLP"|"4305 Middle Settlement Rd New Hartford NY"|"3157387063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/23/2010 10:22:20 AM| 452|"BOCES Albany-Schoh-Schen"|"01900000"|"Building D"|"0010"|"7/19/2010"|"1015 Watervliet-Shaker Road"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1973"|"20370"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"132"|"9,10,11,12"|"0"|"1"|"0"|"132"|"0"|"0"|||"0"|"0"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with water service. Water service enters at Building A for the whole complex."|"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with sanitary service. Each building has its own drain and house trap to a common line under the driveway."|"1"|"S"|"1999"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with gas service. Gas service enters at Building D to serve C and D. Each entrance is metered."|"1"|"UTIL"|"BELOW"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with electrical service. Utility supplies Building C. Buildings A B D E and F are supplied radially from C"|"1"|"S"|"1973"|"15"|"0"|"Roof drains and catch basins are piped underground to the municipal system. There are no current storm drainage problems"|"1"|"S"|"1973"|"15"|"0"|"A small area along Vly Road drains to a swale and to the open drainage along the street. The area was dry and well drained when observed"|"1"|"S"|"2010"|"15"|"0"|"Parking lots drain to catch basins. BOCES has been rebuilding catch basin tops as part of regular maintenance program"|"0"||||"0"||"0"|"MUNI"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"33000"|"Paving is beginning to show signs of age. Replacement may be needed within 5 years"|"1"|"ASPHALT"|"S"|"1998"|"10"|"18000"|"Consider replacement of asphalt walks when road and parking paving is completed Asphalt walks are beginning to show signs of age Replacement may be needed within 5 years"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"On the exterior of the building the concrete block veneer continues below grade and the foundation is not visible There was no cracking observed in the masonry veneer that might suggest foundation issues"|"0"||||"0"||"1"|"S"|"1973"|"15"|"0"|"Gypsum wall board on metal stud framing"|"1"|"S"|"1973"|"10"|"0"|"2x4 Suspended ceilings Suspended ceilings in shop areas collect dirt and more subject to damage Consider removing and exposing structure which may need paint and or acoustical treatment "|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1973"|"10"|"34000"|"Electrical panel replacement recommended Breakers difficult to obtain for branch circuit panels Distribution boards anticipated life is 5 years"|"1"|"S"|"1997"|"10"|"117000"|"Corridors updated to T8s in 1997 All other areas are T12s replaced at failure with T8s"|"1"|"1"|"S"|"2007"|"4"|"26000"|"Telephone VOIP and data systems available throughout building to supplement intercom Intercom system needs replacement"|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1973"|"15"|"0"|"Terrazzo corridors and concrete shop floors"|"0"|||||"0"||"OTHER"|"Floors are unreinforced slab on grade"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"No structural floor systems. Floors are unreinforced slab on grade"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"0"|"Expansion joints have been recaulked Other caulking should be removed and replaced and tested for PCBs and asbestos Lintels should be painted No structural concerns observed"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"15"|"0"|"BOCES has been replacing doors on a yearly basis as a maintenance project"|"1"|"S"|"2004"|"15"|"0"|"Exterior covered ramp connecting buildings Ramps between C D and E Steps to parking lot Recommend painting railings at steps"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1973"|"4"|"27000"|"Each shop has door to the exterior Windows are in good condition though not as thermally efficient as new windows Some sills are loose and need repair Paint lintels Consider phased window replacement in next 5 years"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"0"|"Roofing is at end of useful life Roofing replacement is under contract and scheduled for 2011"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"ELECTRIC"|"S"|"2010"|"15"|"0"|"Replacing heaters as they fail Replacement in this Building October 2010"|"1"|"S"|"1973"|"15"|"0"|"Original fixtures"|"1"|"CV"|"1"|"FURNACE,OTHER"|"Unit ventilation"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"4"|"17000"|"Rooftop Units, AHU satisfactory. Replace rest room exhaust fans"|"0"||||"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop and curbs and connecting ductwork replaced. Some original equipment remains"|"1"|"S"|"1999"|"4"|"26000"|"Original equipment. Budget is to upgrade existing system"|"1"|"S"|"2009"|"15"|"0"|"Fire alarm panel located in Building C"|"1"|"S"|"1973"|"4"|"24000"|"Detectors are heat detectors. Upgrade to addressable smoke detectors"|"0"||||"0"||"1"|"S"|"1997"|"10"|"6000"|"Additional emergency lights recommended in hallways"|"0"||||"0"||"1"|"1"|"0"|"Consider gang toilets Not budgeted Need to identify available space BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance BOCES is implementing required improvements"|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"No General Purpose Classrooms comments are for shop type areas"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Most spaces are Vocational Classrooms Also referred to as shops"|"328000"|"S"|"1"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/23/2010 11:00:31 AM| 453|"BOCES Western Suffolk"|"58930000"|"P.J. Brennan High School"|"0009"|"07/21/2010"|"550 Mount Avenue"|"North Babylon"|" 11704"|"ANNUAL"|"05/01/2011"|"1961"|"119577"|"2"|"6"|"0"|"LSD_DIST"|"INSTRUCT,OTHER_ORG"||"225"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"225"|"0"|"0"|||"34"|"25840"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LGGROUP,REMEDIAL,SCIENCELAB,SPECED,OTHER"|"Weight Room"|"1"|"0"|"0"|"1"|"15000"|"E"|"2005"|"24"|"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"16"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"16"|"0"||"1"|"E"|"2005"|"14"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"U"|"2006"|"1"|"10,000"|"Additional pool needed at front."|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2006"|"1"|"15,000"|"Repair pot holes at rear of building."|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"9"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1961"|"4"|"0"|"Cracks near Gym and Auditorium are being monitored."|"1"|"S"|"1961"|"4"|"0"||"1"|"S"|"1961"|"4"|"0"|"Cracks being monitored."|"1"|"U"|"2007"|"1"|"200,000"|"Replace old ceilings."|"1"|"S"|"1961"|"5"|"0"||"1"|"S"|"S"|"2005"|"10"|"0"||"1"|"S"|"1961"|"10"|"0"||"1"|"S"|"1997"|"6"|"0"||"1"|"1"|"U"|"2008"|"1"|"31,500"|"Some upgrading done. Additional work needed."|"1"|"U"|"2008"|"1"|"290,000"|"Replace old fixtures."|"1"|"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2006"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"10"|"0"||"1"|"COMMON"|"S"|"2006"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1961"|"4"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1961"|"4"|"0"||"1"|"MASONRY"|"S"|"2005"|"11"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"17"|"0"||"1"|"S"|"2001"|"14"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2006"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"14"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2007"|"10"|"0"||"1"|"IRON"|"S"|"2007"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2005"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2005"|"15"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"S"|"2006"|"16"|"0"||"1"|"U"|"1961"|"1"|"52,500"|"Air Handling units need to be replaced."|"1"|"S"|"2005"|"5"|"0"||"1"|"S"|"2006"|"8"|"0"||"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2010"|"2010"|"0"|"Upgrading done."|"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"1967"|"5"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"614,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/23/2010 11:05:41 AM| 454|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS BLDG #6-COSMOTOLOGY "|"0048"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"7056"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"57"|"9,10,11,12"|"0"|"0"|"0"|"57"|"0"|"0"|||"2"|"5800"|"RSRCEROOM,OTHER"|"Cosmetology Lab"|"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"2"|"0"|"New slurry seal is needed."|"1"|"CONCRETE"|"S"|"1970"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1971"|"10"|"0"||"1"|"S"|"S"|"1992"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"10"|"10,000"||"1"|"S"|"1970"|"5"|"30,000"|"Replace existing with T8 fixtures."|"1"|"1"|"S"|"2002"|"10"|"10,000"|"Provide PA system. "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2000"|"2"|"20,000"|"Remove and replace under abatement conditions."|"1"|"INSTRUCT,COMMON"|"U"|"1970"|"10"|"50,000"|"Remove and replace under abatement conditions."|"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2007"|"17"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"3"|"130,000"|"Seams and flashing are failing."|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1971"|"2"|"3,000"|"Provide larger ASME water heater, tank-less gas water heater."|"1"|"S"|"1970"|"2"|"12,500"||"0"||"1"|"OTHER"||"S"|"2002"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"80,000"|"Replace toilet room exhaust/replace Cosmetology exhaust. The rest of the building air handling and ventilation equipment is in good shape."|"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"5"|"0"||"0"||||"0"||"1"|"1"|"86,000"|"Upgrade toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"GOOD"||"447,260"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/23/2010 11:07:07 AM| 455|"Cairo-Durham CSD"|"19030104"|"Cairo-Durham Middle-High School"|"0011"|"10/16/2010"|"1301 ROUTE 145 "|"CAIRO "|" 12413-2148"|"ANNUAL"|"11/01/2012"|"1976"|"135,000"|"1"|"7"|"1"|"DISTRICT"|"INSTRUCT"||"917"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"917"|"0"|"0"|||"61"|"30,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"10"|"0"||"1"|"WELL"|"S"|"2004"|"15"|"0"||"1"|"SITESEPT"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1976"|"10"|"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2010"|"15"|"0"||"1"|"CONCRETE"|"S"|"2010"|"15"|"0"||"0"||||"0"||"1"|"S"|"2010"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"5"|"102,000"|"Replace countertops in library and home and careers; subdivide nurse's area."|"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"S"|"2010"|"5"|"180,000"|"Original 1976 doors to be replaced."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2010"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2010"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2010"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"5"|"440,000"|"Exterior classroom sliding doors to be replaced with windows."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2010"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"15"|"0"||"1"|"PLASTIC"|"E"|"2010"|"15"|"0"||"1"|"COPPER"|"S"|"1996"|"5"|"65,000"|"Replace water pumps and install sequencing controls."|"1"|"IRON"|"S"|"1996"|"10"|"0"||"1"|"OIL"|"S"|"2004"|"10"|"0"||"1"|"S"|"1976"|"5"|"400,000"|"New kitchen layout and equipment needed."|"0"||"1"|"BOILERWATE"||"S"|"1996"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1996"|"5"|"96,000"|"Update temperature control system."|"1"|"S"|"1996"|"5"|"48,000"|"Update fire alarm distribution (existing panel is OK)."|"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"1976"|"1976"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,LIGHTING"|"FULL"|"0"|"1"|"0"|"GOOD"||"$1,331,000"|"S"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, NY 12061"|"518-479-4000"|"mweber@mosaicaa.com"|"Martin Weber"|"12772"|"I ACCEPT"|12/23/2010 11:15:59 AM| 456|"Lockport City SD"|"40040001"|"DeWitt Clinton Elementary"|"0004"|"06/22/2010"|"85 NORTH ADAM STREET "|"LOCKPORT "|" 14094"|"ANNUAL"|"12/01/2010"|"1924"|"35133"|"3"|"3"|"0"|"LSD_NDE"|"INSTRUCT"||"243"|"OTHER"|"0"|"1"|"1"|"243"|"0"|"0"|||"17"|"11045"|"ART,CAFE,GYM,HLTHSUITE,KITCHEN,MUSIC,PREK,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1924"|"10"|"0"|"No backflow prevention device installed"|"1"|"MUN_UTILIT"|"S"|"1927"|"15"|"0"||"1"|"S"|"1924"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2009"|"10"|"0"|"Roof mounted spot lighting metal halide yellowed lenses, cracked lenses, locally operated. Recommend replacing all in kind."|"1"|"S"|"1924"|"10"|"0"||"0"||||"0"||"1"|"S"|"1924"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1994"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1942"|"20"|"0"|"Minor cracking in foundation. Does not appear to be structural."|"0"||||"0"||"1"|"S"|"1924"|"10"|"0"|"Cracking and peeling plaster in multiple locations. Recommend patching."|"1"|"U"|"1980"|"3"|"9600"|"Stained and missing tiles in multiple locations."|"1"|"S"|"1924"|"10"|"0"||"1"|"S"|"S"|"1924"|"10"|"0"|"Water damage to a few doors in basement"|"1"|"S"|"1924"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"2000"|"7"|"0"|"Recommend occupancy sensors."|"1"|"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"U"|"1994"|"3"|"8175"|"Major ripples in one room, stained and dirty"|"1"|"COMMON"|"S"|"1980"|"7"|"0"|"Cracking in floor finishes do not seem to be structural."|"1"|"INSTRUCT,COMMON"|"S"|"1924"|"15"|"0"|"Multiple cracks - do not appear to be structural."|"1"|"INSTRUCT"|"S"|"1924"|"15"|"0"||"OTHER"|"Cast in place concrete"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"U"|"1924"|"5"|"35000"|"Cracking in floor slab throughout school. Recommend structural review."|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"U"|"1924"|"3"|"320000"|"Recommend 20 percent repointing within the next three years, especially on upper 1/3 of building."|"1"|"MASONRY"|"U"|"1924"|"3"|"6000"|"Recommend structural review. Cracking on west side of chimney. Recommend repointing within the next three years."|"1"|"MASONRY"|"S"|"2000"|"15"|"0"||"S"|"S"|"1"|"1"|"1994"|"10"|"0"||"1"|"S"|"1924"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM,OTHER"|"S"|"Y"|"2000"|"15"|"0"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1924"|"15"|"0"|"Sections of cold water piping uninsulated within boiler room."|"1"|"IRON"|"S"|"1924"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1997"|"10"|"0"|"No mixing valve installed."|"1"|"S"|"1924"|"7"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"U"|"1924"|"3"|"80000"|"Boilers are original, covered with insulation. Flue duct has asbestos insulation. Boilers reaching end of useful life."|"1"|"S"|"1924"|"10"|"0"|"Gas service serving boilers is original"|"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"U"|"1924"|"3"|"10000"|"Condensate pumps original, near end of useful life."|"1"|"S"|"1924"|"7"|"0"|"Ductwork is original to building."|"1"|"S"|"1924"|"15"|"0"||"1"|"E"|"2009"|"10"|"0"||"1"|"E"|"2009"|"10"|"0"||"0"||||"0"||"1"|"S"|"1990"|"5"|"0"|"Exit lights are LED with internal battery packs. Emergency lights are wall packs with internal batteries. Ones tested didn't work. Recommend replacing."|"1"|"S"|"2005"|"10"|"0"||"0"|"0"|"5000"|"School is not accessible on exterior or interior. "|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"Lighting just meets need for tasks being performed in each area."|"0"|"0"|"0"|"1"|"0"||"1"|"OTHER"|"basement"|"1"|"OTHER"|"basement"|"0"|"0"||"Basement has had water in it in the past, but staff has informed us that the problem has been fixed."|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"WARMING"|"0"|"1"|"0"|"FAIR"||"468775"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/23/2010 11:24:47 AM| 458|"BOCES Albany-Schoh-Schen"|"01900000"|"Building E"|"0011"|"7/19/2010"|"1015 Watervliet-Shaker Road"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1973"|"19000"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"132"|"9,10,11,12"|"0"|"0"|"0"|"132"|"0"|"0"|||"0"|"0"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with water service Water service enters at Building A for the whole complex"|"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with sanitary service Each building has its own drain and house trap to a common line under the driveway"|"1"|"S"|"1999"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with gas service Gas service enters at Building E to serve E and F Each entrance is metered"|"1"|"UTIL"|"BELOW"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with electrical service Utility supplies Building C Buildings A B D E and F are supplied radially from C"|"1"|"S"|"1973"|"15"|"0"|"Roof drains and catch basins are piped underground to the municipal system There are no current storm drainage problems"|"1"|"S"|"1973"|"15"|"0"|"A small area along Vly Road drains to a swale and to the open drainage along the street The area was dry and well drained when observed"|"1"|"S"|"2010"|"15"|"0"|"Parking lots drain to catch basins BOCES has been rebuilding catch basin tops as part of regular maintenance program"|"0"||||"0"||"0"|"MUNI"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"25000"|"Paving is beginning to show signs of age Replacement may be needed within 5 years"|"1"|"ASPHALT"|"S"|"1998"|"10"|"5000"|"Consider replacement of asphalt walks when road and parking paving is completed Asphalt walks are beginning to show signs of age Replacement may be needed within 5 years"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"On the exterior of the building the concrete block veneer continues below grade and the foundation is not visible There was no cracking observed in the masonry veneer that might suggest foundation issues"|"0"||||"0"||"1"|"S"|"1973"|"15"|"0"|"Concrete block walls and Gypsum wall board on metal stud framing"|"1"|"S"|"1973"|"10"|"0"|"2x4 Suspended ceilings Suspended ceilings in shop areas collect dirt and more subject to damage Consider removing and exposing structure which may need paint and or acoustical treatment"|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1973"|"10"|"32000"|"Electrical panel replacement recommended Breakers difficult to obtain for branch circuit panels Distribution boards anticipated life is 5 years"|"1"|"S"|"1997"|"10"|"111000"|"Corridors updated to T8s in 1997 All other areas are T12s replaced at failure with T8s"|"1"|"1"|"S"|"2007"|"4"|"24000"|"Telephone VOIP and data systems available throughout building to supplement intercom Intercom system needs replacement"|"0"||||"0"||"0"|||||"0"||"0"|"INSTRUCT"|"S"|"1995"|"15"|"0"|"Areas of VCT over VCT exist"|"1"|"INSTRUCT,COMMON"|"S"|"1973"|"15"|"0"|"Terrazzo corridors and concrete shop floors"|"0"|||||"0"||"OTHER"|"Floors are unreinforced slab on grade"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"No structural floor systems Floors are unreinforced slab on grade"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"0"|"Expansion joints have been recaulked Other caulking should be removed and replaced and tested for PCBs and asbestos Lintels should be painted No structural concerns observed"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"10"|"17000"|"BOCES has been replacing doors on a yearly basis as a maintenance project"|"1"|"S"|"2004"|"15"|"0"|"Exterior covered ramp connecting buildings Ramp andor walks between D and E and F"|"0"|||||"0"||"0"||||||"0"|"No windows in this building All shops have exterior doors and natural light via overhead door glazing"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"449000"|"Roofing is at end of useful life Plan for replacement in 2011 2012"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"ELECTRIC"|"S"|"1973"|"4"|"9000"|"Replacing heaters as they fail"|"1"|"S"|"1973"|"15"|"0"|"Original fixtures"|"1"|"CV"|"1"|"FURNACE,OTHER"|"Unit ventilation"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"4"|"17000"|"Rooftop Units AHU satisfactory Replace rest room exhaust fans"|"0"||||"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop and curbs and connecting ductwork replaced Some original equipment remains"|"1"|"S"|"1999"|"4"|"26000"|"Original equipment Budget is to upgrade existing system"|"1"|"S"|"2009"|"15"|"0"|"Fire alarm panel located in Building C"|"1"|"S"|"1973"|"4"|"23000"|"Detectors are heat detectors Upgrade to addressable smoke detectors"|"0"||||"0"||"1"|"S"|"1997"|"10"|"5000"|"Additional emergency lights recommended in hallways"|"0"||||"0"||"1"|"1"|"0"|"Consider gang toilets Not budgeted Need to identify available space BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance BOCES is implementing required improvements"|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"No General Purpose Classrooms comments are for shop type areas"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Most spaces are Vocational Classrooms Also referred to as shops"|"743000"|"S"|"1"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/23/2010 11:42:59 AM| 459|"Argyle CSD"|"64010104"|"Bus Garage"|"5002"|"08/24/2010"|"5023 State Route 40"|"Argyle"|" 12809"|"ANNUAL"|"01/01/2011"|"1969"|"10620"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"bus maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"2"|"775"|"2"|"12,000"|"S"|"2009"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"50"|"0"||"1"|"SITESEPT"|"S"|"1969"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1969"|"25"|"0"|"Overhead electric runs along edge of parking lot."|"1"|"S"|"1969"|"15"|"0"||"0"||||"0"||"1"|"S"|"1969"|"50"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"U"|"1969"|"5"|"$10,000"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2000"|"2"|"$20,000"|"Paving needs upgrade in conjunction with school lot."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1974"|"70"|"0"||"1"|"S"|"1969"|"50"|"0"||"1"|"S"|"1974"|"40"|"0"||"1"|"S"|"1969"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1974"|"10"|"0"||"1"|"S"|"1969"|"35"|"0"||"0"||||"0"||"1"|"1"|"S"|"1974"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1974"|"45"|"0"||"1"|"COMMON"|"S"|"1974"|"45"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1974"|"70"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1974"|"50"|"0"||"1"|"METAL"|"U"|"1969"|"5"|"$9,000"|"Metal chimney in poor condition."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1995"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1974"|"10"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"5"|"$57,000"||"0"|||||"0"||"1"|"COPPER"|"U"|"1969"|"10"|"0"||"1"|"IRON"|"U"|"1969"|"5"|"$95,000"|"Floor drains go into creek; need an oil/sand separator."|"1"|"ELECTRIC"|"S"|"2003"|"10"|"0"||"1"|"S"|"1969"|"10"|"0"||"0"||"1"|"FURNACE"||"S"|"2005"|"25"|"0"||"1"|"S"|"1969"|"10"|"0"||"0"||||"0"||"1"|"S"|"1969"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1969"|"10"|"0"|"Simple thermostats."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|"0"|"20000"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"GOOD"||"$191,000"|"U"|"1"|"Sacco + McKinney Architects, PC"|"11 British American Blvd., Latham, NY 12110"|"518-783-8933"|"csacco@saccomckinney.com"|"Charles J. Sacco"|"015041"|"I ACCEPT"|12/23/2010 11:45:10 AM| 461|"Hauppauge UFSD"|"58050603"|"Whiporwil Elementary"|"0004"|"9/14/10"|"495 Hoffman Lane"|"Hauppauge"|" 11788"|"ANNUAL"|"5/1/11"|"1963"|"99,359"|"2"|"2"|"1"|"LSD_DIST"|"DIST_ADMIN,OTHER_ORG"|"Pre-K Program"|"150"|"Pre-K"|"0"|"1"|"1"|"150"|"0"|"0"|||"24"|"18,700"|"ADMIN,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LGGROUP,MULTIPURPO,PREK,REMEDIAL,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"8,000"|"E"|"2004"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"SITESEPT"|"S"|"1963"|"20"|"0"||"1"|"E"|"2004"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1963"|"20"|"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"CONCRETE,ASPHALT"|"S"|"1963"|"3"|"605,000"|"Reconstruct rear portion of service road & parking lot area along east & southeast, acess road along east & create head-in parking spaces"|"1"|"CONCRETE"|"S"|"2004"|"5"|"73,000"|"Replace sidewalks & curbing at building rear, provide ADA access from Gym, provide ADA ramp outside Rooms 33/36"|"1"|"S"|"1980"|"4"|"5,000"|"Provide fencing to separate upper play area from ADA ramps as there is a 6" step onto ramp which presents a tripping hazard"|"1"|"S"|"1990"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"25"|"0"||"1"|"S"|"1963"|"25"|"16,000"|"Multiple cracks exits along interior stage walls & should be addressed"|"1"|"S"|"1963"|"25"|"0"||"1"|"E"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"15"|"135,000"|"Replace original doorknobs with lever, install magnetic hold opens, B label doors and remaining original interior classroom doors"|"1"|"S"|"1963"|"20"|"0"||"1"|"S"|"1963"|"10"|"0"||"0"|"0"|"S"|"1963"|"5"|"22,000"|"Upgrade interior panels to address electrical needs"|"1"|"S"|"2004"|"12"|"0"||"1"|"1"|"NF"|"1963"|"15"|"38,000"|"Recommend a minimum of an emergency call system be installed throughout the building"|"0"||||"0"||"1"|"COMMON"|"E"|"2007"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"296,000"|"Recommend replacement of all remaining VAT flooring. This should be done on a priority basis starting with the 1st floor classrooms"|"1"|"COMMON"|"S"|"1963"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2006"|"12"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1963"|"25"|"26,000"|"After exterior building overhangs outside the gym & AP were removed, existing copper counterflashing & roof flashing were left, but could be cut away w/ 2 courses of brick which contain 40 yrs work of roof flashing "|"1"|"MASONRY"|"S"|"1963"|"5"|"28,000"|"Work should take place at 2 existing chimneys including replacement of both chimney caps"|"0"|||||"0"||"S"|"S"|"1"|"1"|"1963"|"4"|"156,000"|"Replace all remaining exterior doors, frames & hardware. At that time change basement pairs of exit doors to swing out into the direction of travel"|"1"|"S"|"1963"|"5"|"7,000"|"Repair spalling concrete & replace railing outside Accounts Payable office"|"0"|||||"0"||"1"|"STEEL"|"U"|"Y"|"1963"|"2"|"1,211,000"|"Existing windows & glass block units are original to the bldg & should be replkaced. Glass block should be replaced w/ mechanically operated window units. "|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"12"|"0"||"1"|"PLASTIC"|"S"|"2003"|"12"|"0"||"1"|"IRON,COPPER"|"S"|"1963"|"10"|"0"||"1"|"IRON"|"S"|"1963"|"10"|"0"|"Horizontal runs in basements showing signs of rust & should be monitored"|"1"|"OIL"|"E"|"2004"|"10"|"0"||"1"|"S"|"1963"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1963"|"5"|"548,460"|"Remove 2 Series 64, 125 HP Smith Mills hot water boilers, install 2 HP Smith 4500A cast iron sectional hot water boilers & Powerflame burners, remove ACBM from in & around boilers. "|"1"|"S"|"1963"|"5"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1963"|"20"|"260,000"|"Provide int & ext non-student occupied spaces mechanically ventilated to provide ventilation rate of 20 CFM per person & mechanical cooling to provide 74 F temp if necessary"|"1"|"S"|"1963"|"5"|"445,000"|"Replace 27 existing Nesbit hot water UV's, paint storage room ventilation, install new utility fan to provide ventilation for existing basement level, rooftop support & roof repair - relocate small mechanical/electrical systems"|"1"|"S"|"1963"|"10"|"0"||"1"|"S"|"1963"|"5"|"174,000"|"Recommend day/night control panel be upgraded to a new DDC panel, rehabilitate pneumatic controls, rehabilitate existing building exhaust fans "|"1"|"S"|"2000"|"5"|"128,000"|"Continuous upgrades. Recommend complete replacement."|"1"|"S"|"2000"|"5"|"0"|"See Question 82 above"|"1"|"S"|"1963"|"1963"|"0"|"System cleaned annually. Kitchen currently not in use."|"1"|"S"|"2000"|"5"|"63,000"|"Extend lighting system to uncover portion of the building including basement"|"0"||||"0"||"1"|"1"|"204,000"|"Install handicapped accessible work stations (4 since bldg is not used by grade levels)& sinks throughout. Replace 2 corridor drinking fountains w/ new handicapped accessible water coolers. "|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"|"1"|"1"||"GOOD"||"4,4400,460"|"U"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/23/2010 11:50:51 AM| 462|"Afton CSD"|"08010104"|"Main Building"|"0001"|"11/10/2010"|"18 SAND STREET "|"AFTON "|" 13730"|"ANNUAL"|"11/01/2011"|"1908"|"222560"|"3"|"10"|"1"|"DISTRICT"|"INSTRUCT"||"639"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"0"|"0"|"639"|"0"|"0"|||"67"|"52000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"12000"|"S"|"1993"|"5"|"50,000"|"Being replaced under current project, fill station has settled"|"1"|"MUN_UTILIT"|"S"|"2002"|"30"|"0"||"1"|"SITESEPT"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"30"|"0"|"Add LP Detectors in Tunnels - 500 Gallon tank underground"|"1"|"UTIL"|"BELOW"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"1"|"CONCRETE"|"S"|"2002"|"10"|"0"||"1"|"S"|"1967"|"5"|"100000"||"1"|"S"|"2002"|"20"|"0"|"N"||"RECONCRETE,MASONCON,OTHER"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2002"|"20"|"0"|"Current project providing provisions for foundation waterproofing @ 1908 Building (Stone Foundation)"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||"U"|"2002"|"2"|"245,000"|"School Wide PA, Telephone, Clock Systems require replacing. No local sound system in Pool. No exterior speakers. Items being reviewed for incorporated in current capital project"|"1"|"S"|"1967"|"5"|"0"|"Current capital project upgrading gutters, filtration and drains."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"10"|"0"||"SLABGRADE,CONCRMETAL,WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"1"|"MASONRY"|"U"|"1955"|"3"|"35000"|"Chimney being replaced in current capital project"|"1"|"MASONRY"|"S"|"1908"|"10"|"0"||"S"|"S"|"0"|"0"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"10"|"0"||"METONMET"|"SINGLEPLY,BUILTUP,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"0"|"Major roofing project being completed with current project"|"1"|"PLASTIC"|"S"|"1967"|"5"|"0"|"Being replaced in current capital project"|"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"20"|"0"||"1"|"OTHER"|"S"|"1994"|"5"|"0"|"Being replaced in current project. HX served by Boilers. Electric Dishwaher Booster"|"1"|"S"|"2002"|"10"|"0"||"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1994"|"5"|"0"|"All boiles being replaced in current project"|"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"15"|"0"|"Chiller, Penthouse AHU, RTU, AHU, Small DX"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"U"|"2002"|"5"|"210,000"|"System is close to obsolete and replacement parts may be difficult to acquire. Notification coverage lacking in areas, Exterior notification devices not working. System being reviewed for upgrades in current capital project"|"1"|"U"|"2002"|"5"|"10000"|"Coverage lacking, upgrades being reviewed in current project"|"1"|"S"|"1994"|"1994"|"0"|"Stage, lower level 1908 building are sprinklered. Kitchen hood has ansul system"|"1"|"S"|"2002"|"10"|"60000"|"Coverage lacking in areas"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Basement 1908"|"0"|||"1"|"1"||"Being renovated in current capital project"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"|"1994 dampers being upgraded in current project"|"0"|"1"|"1"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"10000000"|"U"|"1"|"Bivens Architects"|"528 Plum Street, Suite 200, Syracuse, New York 13204"|"3157030987"|"tbivens@bivensarchitects.com"|"Timothy Bivens"|"031103"|"I ACCEPT"|12/23/2010 11:51:12 AM| 463|"Horseheads CSD"|"07090106"|"Fieldhouse"|"7021"|"10/11/10"|"DIVISION STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1965"|"4000"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Atheletic Department support"|"0"|||"0"|"1"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1965"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1965"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1965"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1987"|"5"|"94000"|"Evidence of ponding & subbase failure below pavement in many areas"|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1965"|"15"|"0"||"0"||||"0"||"1"|"S"|"1965"|"15"|"0"||"0"||||"0"||"1"|"S"|"1965"|"15"|"0"|"Consideration should be given to replacing team lockers with larger capacity units"|"1"|"S"|"S"|"1965"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2010"|"30"|"0"||"1"|"S"|"1997"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1965"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1965"|"15"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Some metal wall panels dented by vandals"|"S"|"1965"|"10"|"0"||"1"|"METAL"|"E"|"2010"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"10"|"0"|"ADA hardware added to public access doors"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1965"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1965"|"5"|"16000"|"Metal roof panles should be recoated to extend service life"|"0"|||||"0"||"1"|"COPPER"|"S"|"1965"|"20"|"0"||"1"|"IRON"|"S"|"1965"|"20"|"0"|"Systems are all original construction"|"1"|"NAT_GAS"|"E"|"2010"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"|"Original equipment but repair parts are still available"|"0"||"1"|"FURNACE"||"E"|"2010"|"20"|"0"|"New high efficiency furnace installed"|"1"|"S"|"2010"|"20"|"0"||"0"||||"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"1"||"Toilet rooms are not ADA compliant"|"GOOD"|"Wall panels should be painted to extend service life"|"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"118000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/23/2010 11:55:19 AM| 464|"Valley Stream 30 UFSD"|"28023002"|"Forest Road Elementary School"|"0002"|"08/25/2010"|"16 Forest Road"|"Valley Stream"|" 11581"|"ANNUAL"|"05/01/2011"|"1953"|"46,837"|"1"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"315"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"315"|"0"|"0"|||"24"|"20,843"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1999"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"|"New service in 2003"|"1"|"MUN_UTILIT"|"S"|"1953"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2003"|"20"|"0"||"1"|"S"|"2000"|"10"|"0"|"Roof drains & drywells"|"0"||||"0"||"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"20,000"|"Miscellaneous patching & repair"|"1"|"CONCRETE"|"S"|"2000"|"5"|"50,000"|"Miscellaneous crack & replacement"|"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"1999"|"5"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1953"|"10"|"0"|"Grade beams on piles-continue annual visual inspections."|"1"|"S"|"1953"|"10"|"0"||"1"|"S"|"1953"|"10"|"0"||"1"|"S"|"1986"|"5"|"236,000"|"2x4 tiles are starting to sag-should be targeted for future replacement"|"0"||||"0"||"1"|"U"|"U"|"1953"|"3"|"90,000"|"Replace original doors & hardware (ADA compliant levers & closers)"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1953"|"5"|"20,000"|"upgrade distributionpanels throughout"|"1"|"S"|"1986"|"5"|"236,000"|"Recommend future replacement w/energy efficient fixtures & occupancy sensors"|"1"|"1"|"S"|"1996"|"5"|"85,000"|"Bogen MCP35A rack. Current system over 20 years old-recommend future replacement"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"0"|"Library & Office"|"1"|"INSTRUCT"|"S"|"2004"|"10"|"80,000"|"Remove remaining ACM VAT-scheduled for abatement during the school year"|"1"|"COMMON"|"S"|"1953"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1953"|"10"|"0"|"Gym & Stage"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1953"|"10"|"0"|"Continue w/annual visual inspections"|"MASONRY"|"1"|"1"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"10"|"0"|"Masonry reconstructon recently completed"|"1"|"MASONRY"|"S"|"2000"|"5"|"30,000"|"Upper 1/3 of chimney & cap will need repointing"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1953"|"3"|"42,000"|"Replace 5 pairs, 4 single doors & new ADA hardware & panic devices."|"1"|"S"|"2000"|"5"|"20,000"|"Install concrete sidewalk ramps to remove steps"|"0"|||||"0"||"1"|"ALUMINUM,VINYL"|"U"|"Y"|"2008"|"2"|"0"|"Double hung counterbalances failing on many windows; rescue windows replaced recently. Project is currently at NYSED for permit"|"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1953"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1953"|"10"|"0"||"1"|"OIL"|"S"|"1997"|"5"|"0"|"Bock 51E Series"|"1"|"S"|"1957"|"5"|"0"|"Replacement made as needed-recommend water saver fixtures."|"0"||"1"|"BOILERSTEA"||"S"|"1992"|"10"|"30,000"|"Replacement vacuum condensate pump & associated sump pump"|"1"|"S"|"1992"|"10"|"0"||"1"|"E"|"2003"|"15"|"0"|"Library addition (Media Center) various window units"|"1"|"S"|"1953"|"3"|"350,000"|"Recommend starting UV replacement plan. Add mechanical ventilation to student occupied unventilated spaces"|"1"|"S"|"2000"|"3"|"30,000"|"Survey & replace steam traps"|"1"|"S"|"2003"|"5"|"0"|"Library-Gym"|"1"|"S"|"1986"|"5"|"40,000"|"RecommendDDC building-wide energy management system"|"1"|"S"|"2003"|"20"|"0"|"Simplex Series 4010"|"1"|"S"|"2003"|"20"|"0"|"Simplex Series 4010"|"1"|"S"|"2000"|"2000"|"0"|"Kitchen hood annually inspected by NCFM"|"1"|"S"|"1998"|"10"|"0"|"recommend future replacement w/energy efficient LED"|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"FL_NOT_Ful"|"FAIR"|"Recommend future replacement w/energy efficient fixtures & occupancy sensors"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||"FULL"||"1"||"GOOD"||"1,359,000.00"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/23/2010 12:22:57 PM| 465|"BOCES Western Suffolk"|"58930000"|"James E. Allen Alternative School"|"0025"|"07/16/2010"|"31 LEE AVE "|"WHEATLEY HTS "|" 11798"|"ANNUAL"|"05/01/2011"|"1965"|"60797"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"65"|"7,8,9,10,11,12"|"0"|"0"|"0"|"65"|"0"|"0"|||"8"|"6400"|"ADMIN,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,REMEDIAL,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10000"|"S"|"2007"|"18"|"0"||"1"|"MUN_UTILIT"|"S"|"1965"|"6"|"0"||"1"|"SITESEPT"|"S"|"1965"|"6"|"0"||"1"|"E"|"2009"|"19"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2003"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"U"|"1965"|"1"|"50,000"|"Remove pockets of clay around pools."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2006"|"1"|"200,000"|"Replace paving at front parking lot and East driveway."|"1"|"CONCRETE"|"S"|"2009"|"7"|"0"||"0"||||"0"||"1"|"S"|"2007"|"12"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2007"|"7"|"0"|"Crack in basement wall will need repairs."|"1"|"S"|"1965"|"7"|"0"||"1"|"S"|"2007"|"7"|"0"||"1"|"S"|"2009"|"8"|"0"||"0"||||"0"||"1"|"S"|"S"|"2010"|"7"|"0"||"1"|"S"|"1965"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"18"|"0"||"1"|"S"|"2009"|"12"|"0"||"1"|"1"|"S"|"2007"|"12"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2007"|"3"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"3"|"0"||"1"|"COMMON"|"S"|"2007"|"3"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2007"|"12"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"7"|"0"||"1"|"MASONRY"|"S"|"2009"|"7"|"0"||"0"|"N/A"||||"0"||"E"|"E"|"0"|"1"|"2007"|"18"|"0"||"1"|"S"|"1965"|"7"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2007"|"1"|"660,000"|"Replace old windows in original building."|"METONMET,OTHER"|"BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2007"|"1"|"700,000"|"Install new roof insulation and roofing."|"1"|"PLASTIC"|"S"|"1965"|"5"|"0"||"1"|"COPPER"|"S"|"2009"|"12"|"0"||"1"|"IRON,COPPER"|"S"|"2007"|"12"|"0"||"1"|"ELECTRIC"|"S"|"2007"|"12"|"0"||"1"|"S"|"2009"|"2"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2009"|"18"|"0"||"1"|"S"|"2007"|"12"|"0"||"1"|"E"|"2009"|"13"|"0"||"1"|"S"|"2007"|"18"|"0"||"1"|"S"|"2007"|"8"|"0"||"1"|"S"|"2008"|"23"|"0"||"1"|"S"|"2009"|"17"|"0"||"1"|"S"|"2007"|"18"|"0"||"1"|"S"|"2007"|"17"|"0"||"0"||||"0"||"1"|"S"|"2007"|"18"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,610,000"|"S"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/23/2010 12:34:22 PM| 466|"Commack USFD"|"58041003"|"SAGTIKOS ELEMENTARY SCHOOL"|"0017"|"02/17/2010"|"PINEWOOD DRIVE "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1965"|"35000"|"1"|"2"|"1"|"LSD_NDE"|"INSTRUCT"|"Private School"|"300"|"Pre-K"|"0"|"1"|"0"|"300"|"0"|"2"|"GYM,LIB"||"15"|"17030"|"ADMIN,CAFE,PREK,OTHER"|"Intake and Therapy Rooms"|"1"|"0"|"0"|"1"|"10000"|"S"|"2009"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"5"|"0"|"Hot-box RPZ was installed"|"1"|"SITESEPT"|"S"|"1965"|"15"|"0"||"1"|"S"|"1965"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"44"|"0"||"1"|"S"|"1965"|"15"|"0"||"0"||||"0"||"1"|"S"|"1965"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"19"|"0"||"1"|"CONCRETE,ASPHALT"|"U"|"1965"|"1"|"20000"|"Repair or replace walks as needed."|"1"|"E"|"2004"|"35"|"0"||"1"|"NF"|"1965"|"0"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1965"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"U"|"U"|"1965"|"1"|"120000"|"Replace doors as needed."|"1"|"S"|"1965"|"15"|"0"|"Stair to Basement only."|"0"||||"0"||"1"|"1"|"S"|"1965"|"5"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"1"|"S"|"2001"|"11"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"10"|"0"|"Carpet replaced in C.R's."|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"1965"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1965"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"15"|"0"|"Maintenance repairs were made."|"1"|"MASONRY"|"S"|"1965"|"15"|"0"||"0"|||||"0"||"U"|"U"|"0"|"1"|"1965"|"1"|"0"|"Repair or replace exterior doors as needed."|"1"|"S"|"1965"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1965"|"1"|"400000"||"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"1"||"U"|"2009"|"1"|"70000"|"Some repairs were done to the roof but more repirs are needed."|"1"|"GLASS"|"S"|"1965"|"1"|"0"||"1"|"COPPER"|"S"|"1965"|"5"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1965"|"5"|"0"||"0"|||||"0"|"Storage tank for hot water from boiler."|"1"|"S"|"2009"|"5"|"0"|"Some water closets were replaced."|"0"||"0"|"BOILERWATE"||"U"|"1965"|"1"|"400000"|"Replace 2 boilers."|"1"|"S"|"1965"|"5"|"0"||"1"|"S"|"2002"|"40"|"0"||"1"|"S"|"1965"|"5"|"0"||"1"|"S"|"1965"|"5"|"0"||"1"|"S"|"1965"|"5"|"0"||"1"|"U"|"1965"|"1"|"55000"|"Perform full pneumatic rehab and provide DDC head end controller."|"1"|"S"|"2009"|"11"|"0"|"System was made ADA compliant."|"1"|"E"|"2001"|"11"|"0"||"0"||||"0"||"1"|"S"|"2010"|"5"|"0"|"Emergency lights are being replaced."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 610,000"|"U"|"1"|"Tagi A. Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/23/2010 12:34:55 PM| 467|"Valley Stream 30 UFSD"|"28023002"|"Shaw Avenue Elementary School"|"0003"|"08/18/2010"|"99 Shaw Avenue"|"Valley Stream"|" 11581"|"ANNUAL"|"05/01/2011"|"1950"|"82,797"|"1"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"686"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"686"|"0"|"0"|||"36"|"32,680"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"5"|"0"|"#2 Oil"|"1"|"MUN_UTILIT"|"S"|"1950"|"5"|"0"|"Domestic filtration system annual inspection"|"1"|"MUN_UTILIT"|"S"|"2003"|"10"|"0"||"1"|"E"|"2003"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"10"|"20,000"|"Additional site lighting needed 2 pole mounted 400w lights"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"2000"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"280,000"|"Replace playground asphalt"|"1"|"CONCRETE,ASPHALT"|"S"|"1980"|"10"|"30,000"|"Miscellaneous sidewalk & curb replacement"|"1"|"S"|"1980"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"15"|"0"||"1"|"S"|"1950"|"15"|"5,000"|"Miscellaneous crack patching"|"1"|"S"|"1950"|"15"|"5,000"|"Miscellaneous crack patching"|"1"|"S"|"1986"|"5"|"330,000"|"Corridor ceiling replacement-currently at NYSED. 2x4 classroom ceiling starting to sag. Future replacement to 2x2 gid & tile should be considered"|"0"||||"0"||"1"|"S"|"S"|"1950"|"3"|"75,000"|"Replace original doors w/new doors & ADA compliant lever hardware & closers"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"10"|"0"|"Distribution panel upgrade to be undertaken during corridor ceiling replacement currently at NYSED for permit"|"1"|"S"|"1992"|"5"|"330,000"|"Recommend changing to energy efficient T5 lights & occupancy sensors"|"0"|||||"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"0"|"Lirary-Offices"|"1"|"INSTRUCT"|"S"|"2010"|"10"|"87,400"|"Remove remaining ACM/VAT-partial removal to be performed this school year."|"1"|"INSTRUCT"|"S"|"1950"|"10"|"0"|"Janitor's closet, Boiler Room, toilets, Kitchen"|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"20"|"0"|"Gym & Auditorium Stage"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"10"|"0"|"Brick repointing & replacement currently underway"|"1"|"MASONRY"|"S"|"2010"|"5"|"0"|"Future repointing will be needed on top 1/3 of chimney"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1986"|"5"|"60,000"|"Replace old hollow metal doors & hardware"|"0"|"S"|"2000"|"10"|"15,000"|"Miscellaneous cracks & replacement"|"0"|||||"0"||"1"|"ALUMINUM,VINYL"|"U"|"Y"|"2009"|"3"|"0"|"Rescue windows replaced in 2009, plans & spec at NYSED for replacement of remaining windows. Already found"|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"25"|"0"|"All roofs under warranty"|"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"15"|"0"|"Verify filtration system"|"1"|"LEAD"|"S"|"2000"|"15"|"0"||"1"|"OIL"|"S"|"1999"|"10"|"0"||"1"|"S"|"1950"|"10"|"0"|"Recommend future replacement w/water saver fixtures as needed"|"0"||"1"|"BOILERSTEA"||"S"|"2003"|"5"|"500,000"|"Replace 2 of 3 boilers. Boiler #1 remain;convert to hot water heater system as required to unit ventilator repalcement"|"1"|"S"|"2003"|"15"|"0"|"Boiler #1 (new) Gas; #2 (old) Oil/Gas; #3 (old) Oil only"|"1"|"S"|"2003"|"10"|"0"|"Auditorium-various window A/C"|"1"|"S"|"1950"|"3"|"1,280,000.00"|"Recommend 30 new unit ventilators required in rooms w/radiant heat"|"1"|"S"|"1985"|"10"|"10,000"|"Steam trap survey w/report suggesting replacement plan"|"1"|"S"|"2003"|"10"|"0"|"Courtyard additon & Auditorium RTU's"|"1"|"S"|"1986"|"5"|"48,000"|"Replace pneumatic controls w/new building-wide DDC automatic control system"|"1"|"S"|"2003"|"5"|"0"|"Simplex System 4010"|"1"|"S"|"2003"|"5"|"0"|"Simplex System 4010"|"1"|"S"|"2000"|"2000"|"0"|"Kitchen hoold annually inspection by NCFM"|"1"|"S"|"1999"|"5"|"0"|"Annual inspection by NCFM"|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"FL_NOT_Ful"|"FAIR"|"Suggest energy efficient replacements & occupancy sensors"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"1"|"1"|"0"|"0"|"1"|"1"|"0"||"FULL"|"1"|"1"||"GOOD"||"3,170,400.00"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/23/2010 12:58:50 PM| 468|"BOCES Albany-Schoh-Schen"|"01900000"|"Building F"|"0012"|"7/19/2010"|"1015 Watervliet-Shaker Road"|"Albany"|" 12205"|"ANNUAL"|"10/1/2011"|"1973"|"24800"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"132"|"9,10,11,12"|"0"|"0"|"0"|"132"|"0"|"0"|||"0"|"0"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with water service Water service enters at Building A for the whole complex"|"1"|"MUN_UTILIT"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with sanitary service Each building has its own drain and house trap to a common line under the driveway"|"1"|"S"|"1999"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with gas service Gas service enters at Building E to serve E and F Each entrance is metered"|"1"|"UTIL"|"BELOW"|"S"|"1973"|"15"|"0"|"Service is underground and not visible but no problems have been encountered with electrical service Utility supplies Building C Buildings A B D E and F are supplied radially from C"|"1"|"S"|"1973"|"15"|"0"|"Roof drains and catch basins are piped underground to the municipal system There are no current storm drainage problems"|"1"|"S"|"1973"|"15"|"0"|"A small area along Vly Road drains to a swale and to the open drainage along the street The area was dry and well drained when observed"|"1"|"S"|"2010"|"15"|"0"|"Parking lots drain to catch basins BOCES has been rebuilding catch basin tops as part of regular maintenance program"|"0"||||"0"||"0"|"MUNI"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"10"|"25000"|"Paving is beginning to show signs of age Replacement may be needed within 5 years"|"1"|"ASPHALT"|"S"|"1998"|"10"|"0"|"Walk between E and F included with Building E"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"On the exterior of the building the concrete block veneer continues below grade and the foundation is not visible There was no cracking observed in the masonry veneer that might suggest foundation issues"|"0"||||"0"||"1"|"S"|"2004"|"15"|"0"|"Concrete block walls and Gypsum wall board on metal stud framing"|"1"|"S"|"1990"|"15"|"0"|"2x4 Suspended ceilings Suspended ceilings in shop areas collect dirt and more subject to damage Consider removing and exposing structure which may need paint and or acoustical treatment"|"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1973"|"10"|"38000"|"Electrical panel replacement recommended Breakers difficult to obtain for branch circuit panels Distribution boards anticipated life is 5 years"|"1"|"S"|"2007"|"10"|"132000"|"Corridors updated to T8s in 1997 All other areas are T12s replaced at failure with T8s"|"1"|"1"|"S"|"2007"|"4"|"29000"|"Telephone VOIP and data systems available throughout building to supplement intercom Intercom system needs replacement"|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1995"|"15"|"0"|"Areas of VCT over VCT exist"|"1"|"INSTRUCT,COMMON"|"S"|"1973"|"15"|"0"|"Terrazzo corridors and concrete shop floors"|"0"|||||"0"||"OTHER"|"Floors are unreinforced slab on grade"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"15"|"0"|"No structural floor systems Floors are unreinforced slab on grade"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1973"|"15"|"0"|"Expansion joints have been recaulked Other caulking should be removed and replaced and tested for PCBs and asbestos Lintels should be painted No structural concerns observed"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"4"|"22000"|"BOCES has been replacing doors on a yearly basis as a maintenance project"|"1"|"S"|"2004"|"15"|"0"|"Exterior covered walk connecting buildings Walk between E and F"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1973"|"4"|"14000"|"Each shop has door to the exterior Windows are in good condition though not as thermally efficient as new windows Some sills are loose and need repair Paint lintels Consider phased window replacement in next 5 years"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"4"|"532000"|"Roofing is at end of useful life Roofing replacement is under contract and scheduled for 2011"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"GALVANIZED,COPPER,PVC"|"S"|"1973"|"15"|"0"|"Repairing various minor leaks as they occur Original system"|"1"|"ELECTRIC"|"S"|"1973"|"4"|"9000"|"Replacing heaters as they fail"|"1"|"S"|"1973"|"15"|"0"|"Original fixtures"|"1"|"CV"|"1"|"FURNACE,OTHER"|"Unit ventilation"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop Units Mix of new and original equipment"|"1"|"S"|"1999"|"4"|"17000"|"Rooftop Units AHU satisfactory Replace rest room exhaust fans"|"0"||||"0"||"1"|"S"|"1999"|"15"|"0"|"Rooftop and curbs and connecting ductwork replaced Some original equipment remains"|"1"|"S"|"1999"|"4"|"26000"|"Original equipment Budget is to upgrade existing system"|"1"|"S"|"2009"|"15"|"0"|"Fire alarm panel located in Building C"|"1"|"S"|"1973"|"4"|"27000"|"Detectors are heat detectors Upgrade to addressable smoke detectors"|"0"||||"0"||"1"|"S"|"1997"|"10"|"8000"|"Additional emergency lights recommended in hallways"|"0"||||"0"||"1"|"1"|"0"|"Consider gang toilets Not budgeted Need to identify available space BOCES facilities were reviewed by Civil Rights Commission this year for ADA compliance BOCES is implementing required improvements"|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"No General Purpose Classrooms comments are for shop type areas"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Most spaces are Vocational Classrooms Also referred to as shops"|"879000"|"S"|"1"|"Griffith Dardanelli Architects, PC"|"670 Franklin St., Schenectady NY 12305"|"5183700767"|"kgriffith@gdarc.com"|"Karl P. Griffith"|"018227"|"I ACCEPT"|12/23/2010 1:19:51 PM| 470|"Canastota CSD"|"25090106"|"Industrial Arts Garage"|"0002"|"08/04/2010"|"302 ROBERTS STREET "|"CANASTOTA "|" 13032"|"ANNUAL"|"11/01/2010"|"1951"|"16200"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Maintenance storage and bus garage."|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE,OTHER"|"Bus garage."|"1"|"1"|"250"|"0"|"0"|"S"|"1951"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"|"Water is fed from Roberts Street School."|"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"S"|"1951"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1985"|"15"|"0"|"fed off HS transformer, 400 Amp service, 120/208V"|"1"|"S"|"1951"|"25"|"0"||"0"||||"0"||"1"|"S"|"1951"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1951"|"5"|"263,000"|"Recommend replacing pavement, fill cracks, seal coat and restripe parking area north & south of bus storage"|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1951"|"50"|"0"||"1"|"S"|"2000"|"30"|"2,000"|"Patch and paint (moisture at CMU)"|"1"|"S"|"1951"|"19"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1985"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"1"|"U"|"2000"|"5"|"9,000"|"Connected back to HS LAN and PA system, replace fiber feed back to HS, has wireless clocks"|"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"2000"|"15"|"0"||"1"|"COMMON"|"S"|"1951"|"5"|"0"|"Concrete is heaving in some areas. Repair cost in Question 57."|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1951"|"5"|"3,000"|"Recommend repairing floor cracks and heaving concrete (small area)."|"MASONRY"|"0"|"0"||"0"|"0"|"1"|"1"|"1"||"S"|"1951"|"5"|"13,000"|"Clean and repoint brick veneer."|"1"|"MASONRY"|"S"|"1951"|"10"|"0"||"0"|||||"0"||"U"|"U"|"0"|"1"|"1951"|"5"|"15,000"|"Recommend replacing metal man-doors (4 total) - corroded"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1951"|"5"|"100,000"|"Recommend replacing window units."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"1"|"1"||"U"|"1988"|"5"|"332,000"|"Recommend replacing roof."|"0"|||||"0"||"1"|"COPPER"|"S"|"2000"|"20"|"0"||"1"|"IRON"|"U"|"2002"|"5"|"90,000"|"Replace sanitary system in storage room/maintenance shop. Look into separation of sanitary/plumbing line at toilet room."|"1"|"NAT_GAS"|"S"|"2004"|"15"|"0"||"0"|"S"|"2000"|"20"|"12,000"|"Recommend upgrading fixtures in Men's Toilet Room."|"1"|"CV"|"0"|"BOILERSTEA"||"U"|"1972"|"5"|"788,000"|"Replace (2) steam boilers, boiler plant, feed tanks and support equipment."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1972"|"10"|"0"||"1"|"U"|"2000"|"5"|"26,000"|"Replace dampers on some equipment (not working correctly)"|"1"|"S"|"2002"|"15"|"0"||"1"|"U"|"1985"|"5"|"26,000"|"Replace existing 4-zone Simplex 4001 FACP, connect to HS system already wired into bldg."|"1"|"U"|"2000"|"5"|"18,000"|"Replace devices with point addressable devices, remove zone coverage"|"0"||||"0"||"1"|"U"|"1990"|"5"|"9,000"|"Replace fluorescent exit signs, add additional battery pack EM lights"|"0"||||"0"||"1"|"1"|"1800"|"Provide handicapped parking spaces with proper linestriping and metal signs."|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"1"|"POOR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"|"0"|"FAIR"|"District is considering a new transportation facility"|"1,707,800"|"U"|"1"|"King + King Architects"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/23/2010 1:31:17 PM| 472|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS CAMPUS BLDG #8 "|"0050"|"05/11/2010"|"RD 2 "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"8104"|"2"|"2"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"15"|"100,000"|"Additional parking is needed."|"1"|"CONCRETE"|"S"|"1970"|"2"|"20,000"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"15"|"0"||"1"|"S"|"1970"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2008"|"5"|"0"||"1"|"COMMON"|"S"|"2008"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2003"|"10"|"0"||"1"|"S"|"1970"|"2"|"150,000"|"Replace and remove steps, stairs and ramps."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2005"|"20"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON,COPPER"|"S"|"1971"|"6"|"0"||"1"|"ELECTRIC"|"S"|"1990"|"2"|"3,000"|"Not ASME, provide tank-less gas water heater."|"1"|"S"|"1971"|"6"|"3,200"||"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"5"|"5,000"|"Replace toilet room exhaust."|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"5"|"0"||"0"||||"0"||"1"|"0"|"200,000"|"Improvements to building for classroom use and accessibility. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"GOOD"||"481,200"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/23/2010 1:39:50 PM| 473|"Clarence CSD"|"14080106"|"CLARENCE CENTER ELEMENTARY"|"0003"|"10/19/2010"|"9600 CLARENCE CENTER ROAD"|"CLARENCE CENTER"|" 14032"|"ANNUAL"|"07/01/2011"|"1969"|"64942"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"546"|"K,1,2,3,4,5"|"0"|"1"|"0"|"503"|"0"|"43"|"CAFE,LIB"||"31"|"25,485"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"1"|"75,000"|"REPLACE ORIGINAL PARKING LOT/ SITE LIGHTING AND IMPROVE SECURITY LIGHTING."|"1"|"S"|"1988"|"15"|"0"||"0"||||"0"||"1"|"S"|"1993"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2001"|"2"|"219,000"|"REPLACE FRONT / BUS PARKING LOTS."|"1"|"CONCRETE"|"U"|"2001"|"2"|"72,000"|"REPLACE MISC. SIDEWALKS."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"30"|"0"||"1"|"S"|"1970"|"30"|"0"||"1"|"S"|"1970"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"S"|"2001"|"15"|"0"||"1"|"S"|"1947"|"20"|"0"||"0"||||"0"||"1"|"0"|"S"|"2002"|"5"|"32,000"|"INSTALL ADDITIONAL CLASSROOM RECEPTACLES AND PANELBOARDS TO SUPPORT. INSTALL GFCI RECEPTACLES WHERE REQUIRED."|"1"|"S"|"2002"|"5"|"210,000"|"REPLACE REMAINING T12 FLOURESCENT, INCANDESCENT AND INTERIOR HID LIGHTING."|"1"|"1"|"S"|"2002"|"2"|"160,000"|"UPGRADE DATA CABLING. REPLACE PHONE SYSTEM. INSTALL SUB-SOUND SYSTEM IN GYM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2001"|"2"|"70,000"|"REPLACE CARPET IN IN LIBRARY AND CORRIDORS IN 1970'S WING."|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"U"|"1949"|"3"|"50,000"|"REPLACE WOOD FLOOR (AND ASBESTOS)IN AUXILARY GYM, MAIN AND NURSES OFFICES'."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"0"|"0"|"0"||"S"|"1970"|"1"|"84,000"|"MISC. MASONRY RESTORATION."|"1"|"MASONRY"|"S"|"1949"|"20"|"0"||"1"|"MASONRY"|"S"|"1949"|"30"|"0"||"S"|"S"|"1"|"1"|"1970"|"10"|"0"||"1"|"S"|"1970"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2001"|"1"|"118,000"|"REPLACE WINDOWS IN 1970 WING."|"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"U"|"1999"|"3"|"423,000"|"REPLACE ROOF AT 1970 WING."|"1"|"PLASTIC"|"S"|"1999"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"5"|"125,000"|"REPLACE ORIGINAL PIPING IN MISC. LOCATIONS."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"5"|"75,000"|"REPLACE GREASE TRAP FOR KITHCEN, REPLACE KITHCEN BELOW FLOOR PIPING, REPLACE SUMP PUMPS, INSTALL ADDITIONAL ROOF DRAINS."|"1"|"NAT_GAS"|"S"|"2001"|"5"|"80,000"|"REPLACE HOT WATER HEATERS."|"1"|"S"|"2002"|"5"|"80,000"|"REPLACE OLD DRINKING FOUNTAINS, REMOVE CLASSROOM WATER CLOSET AND LAV. REPLACE SINK."|"0"||"1"|"BOILERWATE"||"E"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"U"|"1970"|"5"|"150,000"|"REPLACE LIBRARY HVAC SYSTEM. INCLUDE (6) SPLIT SYSTEMS FOR WORK ROOMS."|"1"|"U"|"1970"|"5"|"825,000"|"REPLACE UNIT VENTS, AIR HANDLING UNITS, EXHAUST FANS AND RELIEF HOODS INCLUDING DISHWASH EXHAUST HOOD."|"1"|"U"|"2002"|"5"|"190,000"|"REPLACE STEAM SYSTEM WITH HOT WATER SYSTEM. REUSE BOILERS."|"1"|"U"|"1969"|"5"|"30,000"|"REPLACE TRANSITE BOILER STACK."|"1"|"U"|"2002"|"0"|"0"|"REPLACE PNEUMATIC CONTROLS WITH NEW DIGITAL CONTROLS. (PRICE INCLUDED IN ITEM ABOVE)"|"1"|"S"|"2002"|"5"|"110,000"|"REPLACE HARDWIRED SYSTEM WITH NEW ADDRESSABLE SYSTEM."|"1"|"S"|"2002"|"2"|"20,000"|"REPLACE SMOKE HEADS ONLY."|"1"|"S"|"2005"|"2005"|"10,000"|"INSTALL BACKFLOW PREVENTOR ON FIRE PROTECTION SYSTEM."|"1"|"U"|"2002"|"1"|"85,000"|"INSTALL EMERGENCY LIGHTING THROUGHOUT BUILDING, REPLACE INCANDESCENT EXIT SIGNS. INSTALL EXTERIOR EMERGENCY LIGHTING."|"1"|"U"|"2002"|"1"|"65,000"|"SEGREGATE EMERGENCY AND STANDBY LOADS, INSTALL NEW OUTDOOR NATURAL GAS GENERATOR."|"1"|"1"|"62,000"|"PROVIDE HANDICAP ACCESSIBILITY TO THE NURSES OFFICE AND INSTALL LEVER HANDLES AT MISC. DOORS."|"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"1"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"1"|"0"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"|"FULL"|"0"|"1"||"FAIR"||"3,700,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesarchtiects.net"|"Scott W. Jones"|"20434"|"I accept"|12/23/2010 1:44:42 PM| 475|"Horseheads CSD"|"07090106"|"Bus Garage"|"5005"|"10/11/10"|"W SAYRE STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1968"|"23490"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus repair garage & transportation offices"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2001"|"20"|"0"||"0"||||"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"5"|"35000"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2001"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2001"|"5"|"325000"|"Several areas of pavement show signs of subbase failure and ponding"|"1"|"CONCRETE"|"S"|"2001"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"20"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"20"|"0"||"1"|"E"|"2001"|"20"|"0"||"0"||||"0"||"1"|"E"|"S"|"2001"|"20"|"0"|"Hareware on remaining original doors should be replaced as part of any major renovation"|"1"|"E"|"2001"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"5"|"8000"|"Replace two remaining 1968 distribution panels"|"1"|"E"|"2010"|"20"|"0"||"1"|"1"|"S"|"2002"|"5"|"10000"|"Replace obsolete phone system with voice over IP system"|"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"20"|"0"||"1"|"COMMON"|"S"|"1968"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"1"|"MASONRY"|"S"|"1968"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2001"|"20"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"20"|"0"|"Should consider recoating original building area roof to prolong service life"|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2001"|"25"|"0"||"1"|"IRON"|"S"|"2001"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"|"Fixtures in original 1968 wing should be replaced as part of any major renovation to match current equipment"|"0"||"1"|"BOILERWATE"||"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"E"|"2005"|"15"|"0"||"1"|"E"|"2005"|"15"|"0"||"0"||||"0"||"1"|"E"|"2001"|"20"|"0"||"0"|"E"|"2009"|"20"|"0"||"1"|"1"|||"GOOD"|"The building presents a positive image to the public"|"GOOD"|"The building is well maintianed"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"370000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartford, NY"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/23/2010 1:55:18 PM| 478|"Tuckahoe UFSD"|"66030203"|"Tuckahoe Middle / High School"|"0002"|"10/18/2010"|"65 SIWANOY BLVD "|"EASTCHESTER "|" 10707"|"ANNUAL"|"03/01/2011"|"1931"|"116,880"|"4"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"567"|"6,7,8,9,10,11,12"|"0"|"0"|"0"|"567"|"0"|"0"||"0"|"28"|"19,600"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"5,000"|"E"|"2008"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1965"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1965"|"20"|"0"|"Video Inspection required every 3 years"|"1"|"S"|"1965"|"20"|"500"|"Pipes should be marked and identified"|"1"|"UTIL"|"BELOW"|"S"|"2000"|"25"|"0"||"1"|"S"|"2008"|"25"|"0"|"Video Inspection required every 3 years"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"8"|"0"||"1"|"CONCRETE"|"S"|"2003"|"0"|"20000"|"Cafeteria plaza northeast end of Siwanoy Boulevard requires total replacement"|"0"||||"0"||"1"|"E"|"2008"|"20"|"0"|"Y"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1931"|"25"|"0"||"1"|"S"|"2008"|"30"|"6000"|"Grilles within fire walls in Offices 115A 115B 115C must be removed to maintain fire rating"|"1"|"S"|"2008"|"30"|"9000"|"Repair 5 foot crack in Rooms 308 and 310 as well as large holes in Closet of Room 308"|"1"|"S"|"2008"|"30"|"17500"|"Leaks at Corridor 100A 207 208 209 212 No ceiling in 252 Data Closet Missing tiles Rooms 135 214 and Cafeteria"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"S"|"2008"|"10"|"12500"|"Non-latching Cafeteria doors Rm 209 214 Missing cylinder Rm 253 Closet Adjust closer Rm 207 208 Missing closer Rm 206 210 211 212 308 309 310 311 313 314 Replace Gym door to Corr 271 and secure frame at Stair E"|"1"|"S"|"1931"|"20"|"0"||"1"|"S"|"2008"|"25"|"0"|"Sign required at original elevator stating OUT OF SERVICE"|"1"|"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"20"|"1500"|"Room 303 pendant fixture not properly secured"|"1"|"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1965"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1980"|"15"|"0"||"1"|"COMMON"|"S"|"1931"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1965"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"na"|"0"|"0"|"0"|"S"|"2008"|"20"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"|"na"|"0"|"0"|"0"|"0"|"0"|"na"|"S"|"2008"|"30"|"60000"|"Repoint brick and original precast pieces above entrances from Siwanoy Boulevard and northeast corner of Gym and loading dock"|"1"|"MASONRY,CONCRETE"|"U"|"1931"|"2"|"55000"|"Repoint masonry Repair or replace crown coping Inspect interior flues"|"1"|"MASONRY,CONCRETE"|"S"|"1931"|"2"|"50000"|"Repoint original decorative precast caps above HS entrance and reset copings and add flashing along Library roof"|"S"|"S"|"0"|"1"|"2008"|"15"|"15000"|"Replace Custodian door overhead garage door and Gas Main louvered door Repair closer at Aud door to lot Missing cylinder exits to courtyard by Cafeteria and Rm 170 Non latching Girl Locker Rm and Life Center"|"1"|"U"|"1965"|"2"|"120000"|"Replace stairs at Middle Road side to driveway and both exits from Gym"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"20"|"1000"|"Rooms 103 105 Art Room 201 require emergency egress windows Potential removal of limit stops"|"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"|"na"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"na"|"S"|"2008"|"12"|"0"|"Remove debris and stored materials throughout Properly relocate phone lines draped across roof"|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1965"|"10"|"0"||"1"|"IRON"|"S"|"1965"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"10"|"0"||"1"|"S"|"2000"|"15"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"7"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"1931"|"8"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"1980"|"10"|"0"||"1"|"S"|"2008"|"2008"|"0"|"Kitchen Hood Inspected through February 28 2011"|"1"|"S"|"2008"|"15"|"1000"|"Replace damaged exit sign and cage at Gym and replace exit sign bulb in Kitchen"|"0"|"S"|||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|"4500"|"Corridor 100A corner of ceiling Room 209 entire ceiling window soffit Rooms 113 207 208 212 301 302 305 310 314 spot ceiling patching"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"|"0"|||"1"|"0"||"FULL"||"1"||"GOOD"||"400000"|"U"|"0"|"Joseph Fernandez, Architect, P.C."|"111 Brook Street Scarsdale NY 10583"|"914 588 5656"|"joseph.fernandez@msn.com"|"Joseph Fernandez, Architect, P.C."|"031546"|"I ACCEPT"|12/23/2010 2:10:47 PM| 479|"Windham-Ashland-Jewett CSD"|"19140104"|"Bus Garage"|"5004"|"12/23/2010"|"5283 State Route 23"|"Windham"|" 12496"|"ANNUAL"|"11/01/2011"|"1981"|"4775"|"1"|"2"|"0"|"DISTRICT"|"OTHER"|"bus maintenance and storage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"5"|"2825"|"0"|"0"|"S"|"1981"|"1"|"18000"|"Tanks are nearing end of useful life. Consider replacement."|"1"|"MUN_UTILIT"|"S"|"2004"|"24"|"5000"|"No meter or backflow preventer in building. Recommend water treatment for hard water."|"1"|"MUN_UTILIT"|"S"|"1981"|"21"|"22000"|"Piping to holding tank (floor drains only) is 18" below ground and freezes. Recommend frost protection for floor drain line. Septic goes to municipal."|"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"23"|"0"||"0"||||"0"||"1"|"S"|"2004"|"44"|"0"||"0"||||"0"||"1"|"S"|"2004"|"44"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2004"|"44"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1981"|"21"|"0"||"1"|"S"|"1981"|"21"|"0"||"1"|"S"|"1981"|"21"|"0"||"1"|"U"|"1981"|"5"|"3000"|"Recommend that ceiling tile and grid should be replaced."|"1"|"S"|"1981"|"10"|"0"||"1"|"S"|"S"|"1981"|"6"|"0"||"0"||||"0"||"1"|"S"|"2004"|"12"|"0"|"Vehicle lift."|"1"|"1"|"S"|"1981"|"1"|"0"||"1"|"U"|"1981"|"0"|"12000"|"Replace T12 with T5's."|"1"|"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"U"|"1981"|"0"|"1000"||"1"|"COMMON"|"S"|"1981"|"24"|"0"|"VCT needs to be replaced."|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"42"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1981"|"21"|"0"||"1"|"METAL"|"S"|"1981"|"21"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1981"|"10"|"10000"||"1"|"S"|"2000"|"21"|"0"|"Exterior steps are only for fuel Inlet."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"NA"|"1981"|"1"|"6000"|"Window leaks."|"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Small roof leak at storage area and bus lift bay."|"S"|"1981"|"5"|"10000"|"Recommend patching roof."|"0"|||||"0"||"1"|"COPPER"|"U"|"1981"|"11"|"500"|"Backflow preventer required on boiler makeup."|"1"|"IRON"|"S"|"1981"|"31"|"0"||"1"|"OIL"|"S"|"2008"|"13"|"0"||"1"|"S"|"1981"|"11"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2003"|"13"|"0"|"Boiler is a fuel oil fired 212 mbh hot water boiler, with high limit aquastat and fuel link valve."|"1"|"S"|"2003"|"30"|"0"|"Three 185 gallon tanks manifolded together."|"1"|"S"|"2003"|"3"|"0"|"One window unit in office area."|"1"|"U"|"1981"|"0"|"30000"|"Make up and ventilation air should be provided to occupied areas and vehicle exhaust system should be upgraded to meet current requirements."|"1"|"S"|"1981"|"11"|"0"|"Hot water distribution piping is copper, work bay is served by unit heaters, and office area is served by fin tube radiation."|"0"||||"0"||"1"|"U"|"1981"|"0"|"15000"|"Controls are electric thermostats, control valves have failed, piping modifications are required to allow new controls to work properly."|"0"|"U"|||"0"||"0"|"U"|||"0"||"0"||||"0"||"0"|"U"|||"0"||"1"|"S"|"2007"|"17"|"0"||"0"|"0"|"90000"||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"POOR"|"No mechanical ventilation is provided in the building."|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"250000"|"U"|"0"|"Bearsch Compeau Knudson Architects and Engineers PC"|"41 Chenango Street"|"607-772-0007"|"bcostello@bckpc.com"|"Robert J. Costello, RA"|"015828"|"I ACCEPT"|12/23/2010 2:32:07 PM| 482|"BOCES Wayne-Finger Lakes"|"43900000"|"Finger Lakes Animal Science"|"0027"|"09/23/2010"|"3501 County Road 20"|"Stanley"|" 14561"|"ANNUAL"|"08/01/2011"|"1982"|"4000"|"1"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"51"|"9,10,11,12"|"0"|"0"|"0"|"51"|"0"|"0"|||"2"|"3400"|"OTHER"|"Classroom/Lab"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"50"|"0"||"1"|"SITESEPT"|"S"|"1993"|"50"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1982"|"17"|"0"||"1"|"S"|"1982"|"20"|"0"||"0"||||"0"||"1"|"S"|"1982"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2005"|"15"|"0"||"1"|"CONCRETE"|"E"|"2005"|"30"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1982"|"20"|"0"||"1"|"S"|"1981"|"30"|"0"||"1"|"S"|"1981"|"30"|"0"||"1"|"S"|"1981"|"5"|"12000"||"0"||||"0"||"1"|"S"|"S"|"1981"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1982"|"15"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"1"|"S"|"1982"|"2"|"5000"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1982"|"10"|"0"||"1"|"COMMON"|"S"|"1982"|"40"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1982"|"48"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1982"|"5"|"50000"|"Metal siding rusting at bottom of panels. Wall panels need to be replaced."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1995"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1981"|"20"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1981"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1982"|"17"|"0"||"1"|"IRON"|"S"|"1982"|"17"|"0"||"1"|"ELECTRIC"|"S"|"1990"|"3"|"12500"|"Not ASME rated. Replace with large electric tank type ASM water heater."|"1"|"S"|"1982"|"7"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1993"|"8"|"40000"|"Existing furnace is two residential units. Replace heating system."|"1"|"S"|"1993"|"23"|"0"||"0"||||"40000"|"Provide air conditioning."|"0"||"1982"|"0"|"40000"|"Ventilation is not per code. Provide new ventilation."|"0"||||"0"||"1"|"S"|"1993"|"22"|"0"||"0"||||"0"||"1"|"S"|"1982"|"10"|"0"||"1"|"S"|"1982"|"10"|"0"||"0"||||"0"||"1"|"S"|"1982"|"13"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"182500"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Steven F. Moolin, R.A."|"021568"|"I ACCEPT"|12/23/2010 2:37:06 PM| 483|"Lockport City SD"|"40040001"|"Emmet Belknap Middle School"|"0002"|"07/07/2010"|"491 HIGH STREET "|"LOCKPORT "|" 14094"|"ANNUAL"|"12/01/2010"|"1939"|"154633"|"3"|"6"|"0"|"PART"|"INSTRUCT"||"645"|"6,7,8"|"0"|"1"|"0"|"600"|"0"|"45"|"OTHER"|"Faculty Lounge"|"33"|"25441"|"AUDITORIUM,CAFE,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1924"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1924"|"15"|"0"||"1"|"S"|"1938"|"10"|"0"|"Paint remainder of piping. Extend relief vent to above roof level."|"1"|"UTIL"|"ABOVE"|"S"|"2009"|"7"|"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"S"|"1924"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"U"|"2007"|"3"|"474000"|"Recommend patching in multiple locations including around catch basins. Patching at Grant Street entrance, and resealing within the next 3 years."|"1"|"CONCRETE,ASPHALT"|"S"|"2007"|"15"|"0"|"Minor cracking in a few locations."|"0"||||"0"||"1"|"U"|"1998"|"3"|"208000"|"N"|"Tennis courts need to be resealed, lines repainted, and nets need to be re-strung properly. Gate bent at hinges."|"MASONCON,OTHER"|"1"|"1"|"0"|"0"|"0"|"0"|"U"|"1994"|"3"|"6590.40"|"Stone base for main staircase is failing at joints and corners."|"0"||||"0"||"1"|"S"|"1994"|"15"|"0"|"Cracking and peeling plaster in multiple locations."|"1"|"S"|"2007"|"10"|"0"|"Tiles mismatched, cracked, missing, and stained."|"1"|"S"|"1994"|"7"|"0"|"Rusted and dented."|"1"|"U"|"U"|"1994"|"3"|"500"|"Barn door. Door appears to be makeshift. Does not lock or latch closed."|"1"|"U"|"1994"|"10"|"0"|"Rubber treads are separating in some areas. Handrails do not extend beyond step."|"1"|"S"|"1938"|"7"|"0"|"VCT floor is mismatched and stained."|"1"|"1"|"S"|"1994"|"5"|"0"|"Recommend replacing the equipment that has exceeded its useful life."|"1"|"S"|"1994"|"5"|"0"|"Recommend providing occupancy sensors."|"1"|"1"|"S"|"1994"|"5"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"1938"|"5"|"0"|"Corners and edges frayed and ripped. Very worn."|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"7"|"0"|"Some scratches and scuff marks."|"1"|"COMMON"|"S"|"1994"|"10"|"0"|"Concrete floor in 1924 wing is cracking and heaving."|"1"|"INSTRUCT,COMMON"|"S"|"1994"|"10"|"0"|"Stained and scuffed throughout."|"SLABGRADE,CONCRMETAL,OTHER"|"Cast in place concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1994"|"20"|"0"|"Majority of floor finishes are cracked. Does not seem to be a structural concern."|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1994"|"15"|"0"|"Control joints drying out and failing"|"0"|"MASONRY,METAL"|"S"|"1938"|"15"|"0"|"Recommend screen over smaller chimney. Recommend minor reporting for all chimneys."|"1"|"MASONRY"|"S"|"2007"|"15"|"0"||"S"|"S"|"1"|"1"|"1994"|"10"|"0"||"1"|"S"|"1977"|"10"|"0"|"Heaving and some cracking"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"10"|"0"|"Recommend removal of old caulking material and replaced with silicone sealant."|"METONMET,OTHER"|"SINGLEPLY,BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"U"|"2007"|"3"|"253400"|"Ballasted over membrane - upper portion. Adhered membrane - lower portion. Stone ballast has been pulled away from all exposed seams indicating water may have been penetrating to floors below."|"1"|"PLASTIC"|"S"|"2007"|"10"|"0"||"1"|"GALVANIZED"|"S"|"1924"|"10"|"0"|"Not insulated or identified."|"1"|"IRON,GALVANIZED"|"S"|"1924"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1924"|"7"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1963"|"5"|"0"|"Flue duct has asbestos insulation boilers reaching end of useful life."|"1"|"S"|"1963"|"7"|"0"||"1"|"S"|"2004"|"7"|"0"||"1"|"S"|"1977"|"5"|"0"|"Ground floor nesbitt unit ventilators, nearing end of useful life."|"1"|"S"|"1997"|"7"|"0"|"System piping in boiler room is original, covered with asbestos insulation. Recommend replacement."|"1"|"S"|"1994"|"7"|"0"|"Ductwork is original to building. Recommend cleaning or replacement."|"1"|"S"|"1994"|"15"|"0"|"Recommend upgrading pneumatic to DDC and converting Johnson Control System to Andover control system."|"1"|"E"|"2009"|"10"|"0"||"1"|"E"|"2009"|"10"|"0"||"0"||||"0"||"1"|"U"|"1994"|"3"|"5000"|"Exit signs are LED. Egress emergency lighting fixtures have exceeded their useful life and recommend replacing."|"1"|"S"|"1994"|"7"|"0"||"1"|"1"|"0"|"There are accessible interior and exterior routes."|"GOOD"||"GOOD"|"some graffiti on brick"|"1"|"1"|"FAIR"|"Can hear mechanical units within auditorium and gym in halls."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"Lighting fixtures utilized in each space provide the adequate lighting levels needed to perform assigned tasks in each area."|"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"||"Evidence of moisture could lead to mold."|"0"|"0"|"0"|"0"|"1"|"1"|"FAIR"|"0"|"0"|"0"|"1"|"0"|"1"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"1"|"LIGHTING"|"FULL"|"0"|"1"|"0"|"GOOD"||"942490.40"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street, Buffalo, NY 14210"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|12/23/2010 2:37:12 PM| 484|"Three Village CSD"|"58020106"|"Arrowhead Elementary School"|"0007"|"8/26/10"|"62 Arrowhead Lane"|"East Setauket"|" 11733"|"ANNUAL"|"5/1/11"|"1965"|"119,499"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"754"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"754"|"0"|"0"|||"57"|"47,600"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"|"Life Skills"|"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"10"|"0"||"1"|"MUN_UTILIT"|"E"|"2007"|"20"|"0"||"1"|"SITESEPT"|"E"|"2007"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"15"|"0"||"1"|"E"|"2007"|"15"|"255,000"|"Provide drainage system in courtyard & along west side of existing building.directionally bore a pipe below the link corridor to get water from roofs & outside courtyard"|"0"||||"0"||"1"|"E"|"2007"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"15"|"42,400"|"Repave area around loading dock. Replace broken curbing."|"1"|"CONCRETE,ASPHALT"|"E"|"2009"|"15"|"26,400"|"Asphalt walks along the west side of the building need to be replaced & asphalt walks should extend from classroom exit door concrete pads to existing sidewalks."|"1"|"E"|"2007"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"1"|"S"|"1965"|"25"|"32,000"|"Cracks at Rm 8, Rm 25, Gym, PE Office (girls'), Stage wall, as well as multiple locations within the existing mini-gym require attention"|"1"|"S"|"1965"|"25"|"0"||"1"|"E"|"2009"|"20"|"316,800"|"Recommend replacement of remaining concealed spline ceilings, replace corridor 2 x 4 ceiling tiles & grid. Cost above is for concealed spline ceilings only."|"0"||||"0"||"1"|"S"|"S"|"2009"|"10"|"222,000"|"Remove drop-down floor stops, wooden or rubber wedges, hook & eye clasps. Building wide interior door replacement program, magnetic hold opens, replace existing doorknobs with lever hardware "|"1"|"S"|"1965"|"20"|"15,000"|"Provide chainlink fence mesh around 2 attic upper stair landings, provide railing enclosure at top of attic stairwell (east attic access)"|"1"|"S"|"1965"|"10"|"0"||"1"|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"12"|"0"||"1"|"INSTRUCT"|"E"|"2009"|"15"|"152,000"|"Recommend replacement of all remaining spaces which still have VAT in place."|"1"|"COMMON"|"S"|"1965"|"25"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"12"|"16,000"|"The existing Auditorium stage floor is in desparate need of attention. Sand & refinish stage floor. Partial replacement is required in the area adjacent to the existing exit doors."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"MASONRY"|"0"|"1"||"1"|"1"|"0"|"1"|"1"||"S"|"1965"|"5"|"103,000"|"Ext masonry recon & misc steel lintel replacement is required at multiple locations, replace damaged door surrounds & columns, reset loose stone on lintels & repoint"|"1"|"MASONRY"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2008"|"15"|"3,500"|"Majority of existing exterior doors replaced in 2002. Replace boiler room exterior door."|"1"|"S"|"1963"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"15,000"|"Several windows throughout the building have improperly functioning counterbalances and are in need of replacement. District should allocate funds on a yearly basis to address this issue. Long range plan to replace windows should be considered"|"METONMET,WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"40"|"96,000"|"Replace existing gutters & cast iron leaders in areas where too low. Renovate existing cupola is required."|"0"|||||"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"15"|"0"||"1"|"IRON"|"S"|"2008"|"15"|"0"||"1"|"NAT_GAS"|"E"|"2004"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"30"|"20,000"|"Recommend replacement of 4 zone valves within main boiler room"|"1"|"E"|"2008"|"15"|"0"|"UV's in 5th & 6th grade wing - heating & cooling"|"1"|"E"|"2008"|"15"|"220,000"|"Provide mechanical ventilation to 4 small group instructional spaces"|"1"|"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"1965"|"1965"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"1"||"Replace 1 or 2 corridor drinking fountains for handicapped accessibility. Replace old mulch at play structure behind "K" wing. New asphalt walks."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"1"|"1"|"GOOD"||"1,535,100"|"E"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/23/2010 2:38:48 PM| 485|"Valley Stream 30 UFSD"|"28023002"|"Clearstream Avenue Elementary School"|"0005"|"07/22/2010"|"60 Clearstream Avenue"|"Valley Stream"|" 11581"|"ANNUAL"|"5/01/2011"|"1923"|"42,398"|"3"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"389"|"1,2,3,4,5,6"|"0"|"0"|"1"|"389"|"0"|"0"|||"21"|"15,637"|"ADMIN,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"2000"|"10"|"0"|"Asphalt pavement surround replaced in 2009"|"1"|"MUN_UTILIT"|"S"|"1950"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"10"|"0"|"Sewage ejector pumps replaced in 2004"|"1"|"S"|"1990"|"5"|"0"|"Kitchen only"|"1"|"UTIL"|"BELOW"|"E"|"2006"|"15"|"0"|"Asphalt pavement surround replaced in 2009"|"1"|"S"|"2010"|"5"|"0"|"Leader & scuppers cleaned out as part of the roof replacement"|"0"||||"0"||"1"|"S"|"2009"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"10"|"5,000"|"Miscellaneous repair"|"1"|"CONCRETE"|"S"|"2000"|"10"|"10,000"|"Miscellaneous crack & repair & replacement"|"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"2000"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1923"|"15"|"0"||"1"|"S"|"1956"|"10"|"0"||"1"|"S"|"1956"|"10"|"5,000"|"Miscellanous plaster repair"|"1"|"S"|"1985"|"5"|"0"|"2x4 tile are starting to sag. Suggest future replacement w/2x2 tiles & grid."|"0"||||"0"||"1"|"S"|"S"|"1923"|"3"|"52,500"|"Suggest door & hardware replacementw/new code compliant ADA hardware"|"1"|"S"|"1923"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"1986"|"5"|"156,500"|"Should be replaced with energy efficient light fixtures & occupancy sensors in classroom."|"1"|"1"|"S"|"1996"|"5"|"85,000"|"Currentsystem is over 20 years old-recommend future replacement"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2001"|"5"|"0"||"1"|"INSTRUCT"|"S"|"2005"|"10"|"10,000"|"Remove remaining ACM/VAT floor tile"|"1"|"COMMON"|"S"|"1923"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1923"|"5"|"0"|"Gym & Stage"|"SLABGRADE,WOODJOIST,OTHER"|"Reinforced concree structural slabs"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1923"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"2010"|"15"|"0"|"Repointing & cornice replaced this summer"|"1"|"MASONRY"|"S"|"2001"|"10"|"0"||"1"|"MASONRY"|"S"|"2010"|"20"|"0"|"As part of current roof replacement covering w/metal panels inside & new aluminum copping."|"S"|"S"|"0"|"1"|"2000"|"5"|"40,000"|"Gym doors & front entry need replacement. Doors should be scheduled for future replacement."|"1"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"1"|"VINYL"|"U"|"Y"|"1986"|"3"|"0"|"Contact awarded for rescue window replacement. Balance of remaining windows need replacement due to balance failures"|"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"25"|"2,000"|"All roofs under warranty.Current roof replacement under construction"|"0"|||||"0"||"1"|"COPPER"|"S"|"1956"|"10"|"0"||"1"|"IRON"|"S"|"1956"|"10"|"0"||"1"|"OIL"|"S"|"1999"|"5"|"0"||"1"|"S"|"1956"|"5"|"0"|"Individual replacements as needed. Suggest ADA compliant & water saver equipment"|"0"||"1"|"BOILERSTEA,OTHER"|"Unit Ventilation"|"S"|"1993"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"|"Basement library & computer system & various window units"|"1"|"S"|"1960"|"5"|"465,000"|"Recommend replacement plan of UV's that have exceeded useful life."|"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1986"|"5"|"40,000"|"EC-128 & original controls. Recommend installation of building wide DDC energy management."|"1"|"S"|"1997"|"10"|"0"|"Simplex 4002 Series"|"0"|"S"|"1997"|"10"|"0"|"Simplex 4002 Series"|"1"|"S"|"1999"|"1999"|"0"|"Standpipe & Kitchen hood; annual inspection by NCFM."|"1"|"S"|"1999"|"10"|"0"|"Suggest future replacement to LED system"|"0"||||"0"||"1"|"0"|"2,000,000"|"Elevator addition & toilet renovation"|"GOOD"|"Well maintained"|"GOOD"|"Well maintained"|"0"|"1"|"FAIR"||"FL_NOT_Ful"|"FAIR"|"Recommend replacement"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"FAIR"|"Lack of air circulation"|"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||"FULL"||"1"||"GOOD"||"2,886,000"|"S"|"1"|"JOHN A. GRILLO ARCHITECT PC"|"1213 Main Street, Port Jefferson, NY 11777"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"JOHN M. GRILLO"|"027360"|"I ACCEPT"|12/23/2010 2:51:21 PM| 486|"Horseheads CSD"|"07090106"|"Gardner Road Elementary"|"0012"|"10/11/10"|"GARDNER ROAD "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1965"|"63350"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"458"|"K,1,2,3,4"|"0"|"1"|"0"|"458"|"0"|"0"|||"36"|"23200"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1965"|"20"|"0"|"Backflow prevention should be added to service entrance"|"1"|"MUN_UTILIT"|"S"|"1965"|"20"|"0"||"1"|"S"|"1965"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"30"|"0"||"1"|"S"|"1965"|"20"|"0"||"0"||||"0"||"1"|"S"|"1965"|"5"|"25000"||"1"|"S"|"1965"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"1965"|"5"|"10000"|"Outfall discharge basin shoud be clearewd of brush to facilitate flow & maintenance"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"290000"|"Origianl pavement areas are deteriorating due to inadequate subbase and extensive traffic"|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"5"|"5000"|"Asphalt play area should be milled and resurfaced"|"1"|"S"|"2003"|"15"|"0"|"Playgrounds are ADA compliant for all age groups served"|"1"|"S"|"2003"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1965"|"20"|"0"|"Minor splalling at rear walls of A & C wings"|"1"|"S"|"1965"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"|"Maintenance staff replaces damaged tiles on an as-needed basis"|"0"||||"0"||"1"|"S"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"8"|"65000"|"Original distribution panels are obsolete and should be replace"|"1"|"S"|"1997"|"20"|"0"||"1"|"1"|"S"|"2002"|"5"|"70000"|"Replace obsolete phone system with voice or IP system. PA syatem has 15 years remaining life"|"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"0"||"1"|"COMMON"|"S"|"1965"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1965"|"15"|"0"|"Gym flooe recieves periodic sanding & refinishing to extend useful life"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1965"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1965"|"20"|"0"|"Masonry control joints at gym wall above low roof should be recaulked"|"1"|"MASONRY"|"S"|"1965"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1965"|"10"|"0"|"Consider replacement of entrance doors with next renovation project"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"S"|"2003"|"5"|"50000"|"Additional roof drains and tapered insulation required at gym/cafeteria roof to eliminate ponding"|"1"|"PLASTIC"|"S"|"1995"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1965"|"20"|"0"|"Backflow prevention should be installed on water service and boiler make-up"|"1"|"IRON,COPPER"|"S"|"1965"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"|"Original building fixtures should be replaced as part of any major renovation"|"0"||"1"|"BOILERSTEA"||"S"|"1965"|"10"|"0"|"Original boiler should be replaced with smaller modular units for energy conservation"|"1"|"S"|"1965"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"|"Building has several DX cooling units on roof"|"1"|"S"|"1965"|"10"|"0"|"All air handling units & unit vents are original equipment"|"1"|"S"|"2003"|"5"|"25000"|"Duplex pumps should be added to boilers"|"1"|"S"|"2003"|"20"|"0"|"Upgrades made to Kindergarten and office wings in 2003"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2004"|"5"|"12000"|"Visual alarms should be added to classrooms"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"1"|||"GOOD"|"Building presents an attractive appearance to the public"|"GOOD"|"The building is well maintained"|"1"|"1"|"GOOD"|"Building is well zoned to minimize noise disturbance"|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"||"527000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/23/2010 2:57:04 PM| 487|"Rockville Centre UFSD"|"28022103"|"Administration Building"|"1006"|"9/24/10"|"128 Shepherd Street"|"Rockville Centre"|" 11570"|"ANNUAL"|"04/01/2011"|"1948"|"10134"|"2"|"1"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"2000"|"S"|"1988"|"28"|"1,500"|"Provide signage & cage for overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1948"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"40"|"0"||"1"|"S"|"1997"|"37"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1997"|"37"|"0"||"1"|"S"|"1948"|"0"|"28,000"|"Replace 3 roof drain pools, provide basement window well covers, pitch grade away from building."|"0"||||"0"||"1"|"S"|"1948"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"0"||"1"|"CONCRETE"|"S"|"2005"|"15"|"5,000"|"Repair deteriorated concrete sidewalk (270 ft)."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"15"|"0"||"1"|"S"|"1948"|"20"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"7"|"3750"|"Replace board room lighting."|"1"|"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"20"|"0"||"0"|"COMMON"|"S"|"1998"|"15"|"0"||"1"|"COMMON"|"S"|"1998"|"15"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"10"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"15"|"0"||"1"|"MASONRY"|"S"|"1948"|"20"|"0"|"Tuckpoint and add rain diverting cap."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"15"|"0"||"METONMET,WOODONWOOD"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"10"|"70000"|"Replace older section of flat roof."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1997"|"37"|"0"||"1"|"GALVANIZED"|"S"|"1997"|"37"|"0"||"1"|"ELECTRIC"|"S"|"2000"|"10"|"0"||"1"|"S"|"2003"|"43"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2008"|"38"|"0"||"1"|"S"|"2008"|"38"|"0"||"1"|"S"|"1997"|"7"|"1300"|"Repair leak in computer room A/C condensate pump."|"1"|"S"|"1997"|"7"|"224,000"|"Repair leak in board rm., rpr./repl. RT exhaust fan, provide gas fired RTU for FAI to all areas except new wing, relocate mens rm occ. sens to inside mens rm, provide add'l hea in 2 N. offices."|"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"8,000"|"Provide fan shutdown."|"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"271,550"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I ACCEPT"|12/23/2010 2:59:38 PM| 489|"Clarence CSD"|"14080106"|"HARRIS HILL ELEMENTARY SCHOOL"|"0001"|"10/20/2010"|"4260 HARRIS HILL ROAD"|"WILLIAMSVILLE"|" 14031"|"ANNUAL"|"7/1/11"|"1951"|"74,718"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"557"|"K,1,2,3,4,5"|"0"|"1"|"0"|"516"|"0"|"41"|"CAFE,LIB"||"28"|"24,133"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"1"|"150,000"|"REPLACE ORIGINAL PARKING LOT LIGHTING / SITE LIGHTING AND IMPROVE SECURITY LIGHTING."|"0"||||"0"||"1"|"U"|"2002"|"5"|"22,000"|"ADD DRYWELL FOR THE NORTHERN BUS LOOP CATCH BASINS TO ADD AREA RELIEF FROM FLOODING."|"1"|"S"|"2002"|"15"|"0"|"SEE QUESTION #32"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"15"|"0"||"1"|"CONCRETE"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"5"|"36,000"|"REPLACE REMAINING ORIGINAL RECEPTACLES IN ORIGINAL CLASSROOMS AND INSTALL ADDITIONAL OUTLETS."|"1"|"S"|"2002"|"1"|"155,000"|"REPLACE REMAINING T12 FLUORESCENT, INCANDESCENT AND REPLACE STAGE LIGHTING."|"1"|"1"|"S"|"2002"|"5"|"150,000"|"UPGRADE COMMUNICATIONS CABLING, REPLACE PHONE SYSTEM, INSTALL SUB-SOUND SYSTEM IN MAIN GYM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2001"|"5"|"242,000"|"REPLACE CARPET."|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"U"|"2001"|"2"|"47,000"|"REPLACE GYM FLOOR AND REFINISH STAGE FLOOR."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1951"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"25"|"0"||"1"|"MASONRY"|"S"|"2001"|"1"|"50,000"|"REMOVE OBSOLETE CHIMNEY."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"2"|"75,000"|"REPLACE MISC. EXTERIOR DOORS."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"5"|"80,000"|"REPLACE HOT WATER HEATERS."|"1"|"S"|"2002"|"5"|"77,000"|"REPLACE ORIGINAL PLUMBING FIXTURES."|"0"||"1"|"BOILERWATE"||"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"2"|"30,000"|"INSTALL HVAC TO CLASSROOM 211, AIR CONDITIONING TO ELECTRIC LAN ROOM."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2002"|"5"|"55,000"|"UPGRADE CURRENT SYSTEM TO A FULLY ADDRESSABLE SYSTEM AND BRING INTO CURRENT COMPLIANCE."|"1"|"U"|"2002"|"1"|"12,000"|"REPLACE 10+ YEAR OLD AND 8 YEAR OLD SMOKE HEADS ONLY."|"1"|"S"|"2002"|"2002"|"0"||"1"|"U"|"2002"|"1"|"35,000"|"UPGRADE EMERGENCY LIGHTING IN VARIOUS AREAS."|"1"|"U"|"2002"|"1"|"50,000"|"SEGREGATE STANDBY AND EMERGENCY CIRCUITING. INSTALL ADDITIONAL NEW OUTDOOR GENERATOR. "|"1"|"1"|"4,000"|"INSTALL MISC. LEVER HANDLES."|"FAIR"||"FAIR"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"FAIR"||"1,300,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main St., Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I accept"|12/23/2010 3:23:36 PM| 490|"BOCES Western Suffolk"|"58930000"|"James E. Allen Dix Hills Elementary "|"0017"|"07/12/2010"|"762 DEER PARK RD "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1973"|"98000"|"1"|"9"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"235"|"K,1,2,3,4,5,6"|"0"|"1"|"0"|"235"|"0"|"0"|||"47"|"37000"|"ADMIN,ART,COMPROOM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"20000"|"U"|"1973"|"1"|"75,000"|"Replace with a double-wall fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1973"|"12"|"0"||"1"|"SITESEPT"|"S"|"1973"|"12"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1973"|"2"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1973"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1988"|"1"|"18,000"|"Provide sealcoating."|"1"|"CONCRETE"|"U"|"1973"|"1"|"15,000"|"Front sidewalk needs repairs."|"1"|"S"|"2007"|"12"|"0"|"Monitor rust in equipment at North side."|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1973"|"12"|"0"||"1"|"S"|"1973"|"10"|"0"||"1"|"S"|"1973"|"5"|"0"||"1"|"U"|"1973"|"1"|"275,000"|"Asbestos surfacing is being abated."|"1"|"S"|"2008"|"23"|"0"||"1"|"U"|"U"|"1973"|"1"|"150,000"|"Replace doors as required."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1994"|"7"|"0"||"1"|"U"|"1973"|"1"|"150,000"|"Renovate fixtures at the time that ceiling abatement is performed."|"1"|"1"|"E"|"2004"|"9"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"2004"|"1"|"25,000"|"Install new carpet in Administration Offices 132, 134, 603, 604, and 605, and 400 Learning Lab."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"7"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"1973"|"12"|"0"||"1"|"METAL"|"U"|"1973"|"1"|"15,000"|"Aging metal chimney needs to be replaced."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1973"|"1"|"130,000"|"Replace where required with FRP doors."|"1"|"S"|"2009"|"2"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"NA"|"1973"|"1"|"850,000"|"Replace with energy efficient windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"1"|"1"||"S"|"2009"|"19"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1973"|"7"|"0"||"1"|"IRON"|"U"|"1973"|"7"|"65,000"|"Classroom sink pumps need replacement."|"1"|"OIL"|"U"|"1973"|"1"|"75,000"|"Provide new independent H.W.H."|"1"|"S"|"1990"|"2"|"0"||"0"||"1"|"BOILERWATE"||"U"|"2002"|"1"|"700,000"|"Boiler needs to be replaced."|"1"|"S"|"1973"|"7"|"0"||"1"|"S"|"2004"|"13"|"0"||"1"|"U"|"2004"|"1"|"50,000"|"Replace roof exhaust fans."|"1"|"S"|"2004"|"13"|"0"||"1"|"U"|"1973"|"1"|"225,000"|"Damper and damper controls need to be refurbished."|"1"|"U"|"2004"|"1"|"45,000"|"Compressor needs replacement."|"1"|"S"|"2003"|"8"|"0"||"1"|"S"|"1973"|"8"|"0"||"1"|"S"|"1985"|"1985"|"0"||"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"0"|"POOR"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2,863,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/23/2010 3:34:07 PM| 491|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"MODULAR CLASSROOM @ COOPERS "|"0052"|"05/11/2010"|"1 VOCATIONAL DRIVE "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1990"|"1554"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"22"|"9,10,11,12"|"0"|"0"|"0"|"22"|"0"|"0"|||"2"|"1484"|"REMEDIAL"||"0"||||||||"0"||"1"|"WELL"|"S"|"2005"|"10"|"0"||"1"|"SITESEPT"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2005"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2005"|"5"|"0"||"1"|"OTHER"|"S"|"2005"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"2"|"10,000"||"1"|"COMMON"|"S"|"2000"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2005"|"15"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"15"|"0"||"1"|"S"|"2005"|"2"|"15,000"||"0"|||||"0"||"1"|"VINYL"|"S"|"NA"|"1990"|"10"|"0"||"WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"2"|"25,000"||"0"|||||"0"||"1"|"COPPER"|"S"|"2005"|"10"|"0"||"1"|"COPPER,PVC"|"S"|"2005"|"10"|"0"||"1"|"ELECTRIC"|"S"|"1990"|"2"|"10,000"|"Not ASME, provide tank-less water heater."|"1"|"S"|"1990"|"5"|"0"||"0"||"0"|"OTHER"||"S"|"1978,1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"||||"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"2005"|"5"|"0"||"1"|"S"|"2005"|"5"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"1"|"10,000"|"Replace ramp."|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"180,000"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/23/2010 3:36:17 PM| 492|"Rockville Centre UFSD"|"28022103"|"Jennie E. Hewitt Elementary School"|"0007"|"09/16/2010"|"446 DeMott Aenue"|"Rockville Centre"|" 11570"|"ANNUAL"|"04/01/2011"|"1928"|"41158"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"446"|"K,1,2,3,4,5"|"0"|"0"|"0"|"446"|"0"|"0"|||"25"|"20,000"|"ADMIN,ART,AUDITORIUM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1928"|"28"|"1,500"|"Provide signage & cage at overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1928"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1928"|"5"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1928"|"5"|"0"||"1"|"S"|"1928"|"5"|"0"||"0"||||"0"||"1"|"S"|"1928"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"150,000"|"Add loop at De Mott Avenue & provide additional parking (13,000 sf)"|"1"|"CONCRETE"|"S"|"2005"|"15"|"23,000"|"Extend line up area sidewalk (1,200 sf), replace 50 sf of cracked concrete sidewalk."|"1"|"S"|"1999"|"9"|"2000"|"Replace 3 broken swings."|"1"|"S"|"2005"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"10"|"0"|"Replace knobs with lever locksets."|"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"1"|"S"|"1997"|"37"|"26,000"|"Provide additional classroom receptacles."|"1"|"S"|"1997"|"7"|"8,600"|"Replace missing lighting lens, replace damaged exterior security lighting lens, provide additional lighting in rear parking area, provide additional lighting in nurses office"|"1"|"1"|"S"|"1986"|"5"|"303,000"|"Repalce PA/intercom & tie to phone switch, provide scoreboard in gym, replace central clock system with wireless type & provide 13 additional Smart Boards."|"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1997"|"20"|"0"||"1"|"COMMON"|"S"|"1997"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"20"|"0"|"Sand & refinish several classroom floors & stage."|"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete on metal lath"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"20"|"0"||"1"|"MASONRY"|"S"|"1938"|"20"|"0"||"1"|"MASONRY"|"S"|"1938"|"20"|"0"||"S"|"S"|"0"|"1"|"1980"|"5"|"0"|"Replace hollow metal exterior doors with FRP"|"1"|"S"|"1997"|"20"|"0"|"Repair two exterior stairs at rear of building"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"20"|"0"||"METONMET,WOODONWOOD"|"BUILTUP,SLATE,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1928"|"5"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1997"|"37"|"0"||"1"|"OIL"|"S"|"2005"|"15"|"0"||"1"|"S"|"2000"|"40"|"7,500"|"Provide vacuum breaker on slop sinks (2), provide 2 additional exterior hose faucets"|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1978"|"8"|"570,000"|"Replace Weil McLain steam boilers and provid lead/lag panel."|"1"|"S"|"1978"|"8"|"0"||"1"|"S"|"1997"|"7"|"290,000"|"Provide A/C for gym"|"1"|"S"|"2005"|"45"|"334,000"|"ProvexhforBRs8,openCRrelief vents,provide FAImathrm,rm7,lib,fac,Princsec area, nurse,phys.ed.,coaches,reflt rm,rms29A,31,30 office,provideVFDaudtH&Vlessnoise,repl bearingatticexhfan,remove debrisFAI&screen,exhforwireclst,provide sleeves on UV"|"1"|"S"|"1986"|"26"|"76,500"|"Replace steam traps"|"1"|"S"|"2005"|"45"|"4,000"|"Seal mechanical room duct penetration"|"1"|"S"|"1997"|"7"|"160,000"|"Tie all units to day/night system to ensure proper operation, refurbish ATC system"|"1"|"S"|"1980"|"5"|"0"||"1"|"S"|"1980"|"5"|"650"|"Remove smoke detector cover in room 31"|"0"||||"0"||"1"|"S"|"1980"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"1"||"FAIR"||"1,956,750"|"S"|"0"|"BBS Architects and Engineer PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I ACCEPT"|12/23/2010 3:54:11 PM| 493|"Canastota CSD"|"25090106"|"South Side School"|"0004"|"09/07/2010"|"HIGH STREET "|"CANASTOTA "|" 13032"|"ANNUAL"|"11/01/2010"|"1951"|"27690"|"1"|"1"|"1"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"222"|"2,3"|"0"|"0"|"0"|"200"|"0"|"22"|"STORAGE,OTHER"|"Corridor as teaching space"|"14"|"11531"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"10"|"0"||"1"|"MUN_UTILIT"|"U"|"1964"|"5"|"61,000"|"Existing sanitary requires maintenance yearly. Recommend removal of exg. infrastructure and installation of new PVC piping."|"1"|"S"|"1964"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1964"|"15"|"0"||"1"|"S"|"1964"|"25"|"0"||"0"||||"0"||"0"|"S"|"1964"|"25"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1964"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2003"|"5"|"53,000"|"Recommend crack filling, sealing, and restriping of pavement, and replacement of deteriorated curbing along First St."|"1"|"CONCRETE,ASPHALT"|"U"|"2003"|"5"|"40,000"|"Recommend replacement of concrete walk at north, south and west sides of building."|"1"|"S"|"2004"|"15"|"0"||"1"|"U"|"1964"|"5"|"27,000"|"N"|"Recommend replacement of deteriorated backstop in northeast corner of playfield."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1951"|"35"|"0"||"1"|"S"|"1964"|"30"|"0"||"1"|"S"|"1964"|"10"|"0"||"1"|"U"|"1957"|"5"|"65,000"|"Recommend replacing glued-up ceiling tiles."|"0"||||"0"||"1"|"U"|"U"|"1964"|"5"|"68,000"|"Replace interior doors with rated doors and ADA compliant hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"1"|"U"|"2005"|"5"|"149,000"|"Upgrade LAN hardware add drops for 1Gb, replace phone system"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1988"|"5"|"51,000"|"Recommend replacing carpet (and abating VAT underneath)"|"1"|"INSTRUCT,COMMON"|"U"|"1988"|"5"|"268,000"|"Recommend replacing VAT and VCT."|"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"30"|"0"||"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1964"|"5"|"15,000"|"Clean and repoint brick veneer. Replace caulking and sealant. Repair damaged brick."|"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1975"|"5"|"81,000"|"Replace all metal doors."|"1"|"U"|"1964"|"5"|"35,000"|"Replace freestanding concrete stairs/railing at south side of building."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1991"|"5"|"70,000"|"Replace windows in 1957 wing (single pane windows)"|"WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1964"|"20"|"3,000"|"No insulation on exposed piping at water heaters (3)."|"1"|"IRON"|"S"|"1964"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2007"|"13"|"0"||"1"|"U"|"1964"|"10"|"11,000"|"Urinals are inoperable; some fixtures inoperable on sinks/bubblers."|"0"||"1"|"BOILERWATE"||"S"|"2003"|"20"|"0"|"Patterson Kelly 1275 MBH output (2003), Burnham 3353 MBH output (1997)"|"1"|"S"|"1997"|"20"|"0"|"Updated as part of 1997 boiler project"|"1"|"S"|"2000"|"10"|"0"|"Window air conditioning at Main Office"|"1"|"U"|"1997"|"5"|"88,000"|"CR UV's replaced in 1997, but Main Office, Caf, and Lib Ventilation Sys is orig and near end of useful life"|"1"|"S"|"2003"|"15"|"0"|"Replaced pumps and piping in 1997 project"|"1"|"U"|"1951"|"5"|"15,000"|"When Main Office, Caf, and Lib Ven Sys are replaced, update control dampers. Recommend cleaning ductwork."|"1"|"S"|"2003"|"15"|"0"|"Replaced controls with Capital and Performance Contract Projects"|"1"|"S"|"1992"|"9"|"0"|"Mirtone 8000 Series FACP (room for expansion)"|"1"|"S"|"1992"|"9"|"0"||"1"|"S"|"1992"|"1992"|"0"||"1"|"S"|"1996"|"15"|"0"||"0"||||"0"||"1"|"1"|"53000"|"Gym door is not ADA accessible (front door is only accessible exterior door). Provide interior ramp that is ADA accessible slope of 1:12 ($50,000) Recommend restriping existing handicapped parking spaces and providing metal signs ($3,000)."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|"CLASSROOMS"||"1"|"1"|"0"|"In slab-on grade area (1975 wing)"|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"0"|"0"|"FAIR"|"District is considering consolidated new elementary & closing Peterboro / South Side "|"1,153,000"|"U"|"1"|"King + King Architects LLP"|"358 W. Jefferson Street, Syracuse, New York 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/23/2010 3:55:09 PM| 494|"Wainscott Comn SD"|"58030208"|"NEW WAINSCOTT SCHOOL "|"0002"|"10/25/2010"|" 47 Main Street "|" Wainscott"|"11975-0079"|"ANNUAL"|"05/01/2011"|"2008"|"4200"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"17"|"K,1,2,3"|"0"|"0"|"0"|"17"|"0"|"0"|||"2"|"1800"|"MULTIPURPO,RSRCEROOM,TEACHRSRC"||"1"|"1"|"550"|"0"|"0"|"E"|"2008"|"23"|"0"||"1"|"MUN_UTILIT"|"E"|"2008"|"38"|"0"||"1"|"SITESEPT"|"E"|"2008"|"38"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"E"|"2008"|"38"|"500"|"Budget to clear vegetation from transformer"|"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"2008"|"18"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2008"|"23"|"0"||"1"|"CONCRETE"|"E"|"2008"|"23"|"0"||"1"|"S"|"2008"|"18"|"4500"|"Budget for one set of swings"|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2008"|"58"|"0"||"1"|"E"|"2008"|"18"|"300"|"Budget for fire stopping"|"1"|"E"|"2008"|"18"|"0"||"1"|"S"|"2008"|"18"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"18"|"0"||"1"|"S"|"2008"|"28"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"1"|"E"|"2008"|"28"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"1"|"E"|"2008"|"13"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"18"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"18"|"1500"|"Budget for vinyl sheet flooring repair"|"0"|||||"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2008"|"58"|"0"||"STEEL,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"38"|"300"|"Budget for caulking"|"1"|"METAL"|"S"|"2008"|"11"|"750"|"Budget for new chimney cap"|"0"|||||"0"||"S"|"S"|"1"|"0"|"2008"|"18"|"0"||"1"|"S"|"2008"|"23"|"0"||"0"|||||"0"||"1"|"WOODCLAD"|"E"|"Y"|"2008"|"28"|"800"|"Budget for repairs"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"28"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2008"|"28"|"0"||"1"|"IRON,COPPER"|"E"|"2008"|"38"|"0"||"1"|"OIL"|"S"|"2008"|"18"|"0"||"1"|"E"|"2008"|"18"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2008"|"38"|"0"||"1"|"S"|"2008"|"38"|"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"2008"|"18"|"0"||"0"||||"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"18"|"0"||"0"|"E"|||||"1"|"E"|"2008"|"18"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"8650"|"E"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Douglas Adil RA"|"021836"|"I accept"|12/23/2010 4:00:32 PM| 495|"Horseheads CSD"|"07090106"|"Ridge Road Elementary "|"0008"|"10/11/10"|"RIDGE ROAD "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1956"|"52290"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"403"|"K,1,2,3,4"|"0"|"1"|"0"|"403"|"0"|"0"|||"30"|"21500"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"20"|"0"||"1"|"S"|"1956"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"30"|"0"|"Consider relocating service entrance poles clear of pavement to improve circulation"|"1"|"S"|"1960"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1956"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"1960"|"20"|"0"|"Some minor erosion present at discharge of drain line, stone lining should be installed to protect bed"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"5"|"185000"|"Large areas of pavement have evidence of subbase deterioration and ponding."|"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"5"|"12000"|"District has an ongoing program of sidewalk replace each summer to repair problem areas"|"1"|"S"|"2008"|"20"|"0"|"Playgrounds have ADA compliant aparatus for all age groups in the school"|"1"|"S"|"2005"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"30"|"0"||"1"|"S"|"1960"|"30"|"0"||"1"|"S"|"1960"|"30"|"0"||"1"|"S"|"2003"|"20"|"0"|"Custodial staff replaces worn or damaged tiles on an as-needed basis"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"S"|"1960"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"5"|"24000"|"Three orginal panels i nthe 1956 wing of the building should be replaced"|"1"|"S"|"1997"|"15"|"0"|"T-8 fixtures used in classrooms & corridors, T-5 in gym"|"1"|"1"|"S"|"2002"|"5"|"70000"|"Obsolete phone system should be replace with voice over IP system, PA system has 15 years remaining life expectancy"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"COMMON"|"S"|"2003"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"10"|"0"|"Gym floor is sanded & refinished periodically to extend useful life"|"SLABGRADE,OTHER"|"Flat-slab reinforced concrete over crawlspaces"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Some areas of EIFS panels damaged by mower impact"|"S"|"1960"|"30"|"0"|"BRickwork at cafeteria exit door needs repointing"|"1"|"MASONRY"|"S"|"1956"|"30"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Steps at Cafeteria exit and ramp at main entrance need resurfacing"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"30"|"0"|"All original building windows have been replaced"|"METONMET,OTHER"|"SINGLEPLY,BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1960"|"20"|"0"|"1960 addition need backflow prevention on building service entracne and boiler make-up system "|"1"|"IRON,COPPER"|"S"|"1960"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"15"|"0"|"Units are standard efficiency tank type units"|"1"|"S"|"2008"|"5"|"30000"|"Fixtures in original building area not previously upgraded should be replaced"|"0"||"1"|"BOILERSTEA"||"S"|"1987"|"10"|"0"|"Boilers are orgininal, burners replaced in 1987"|"1"|"S"|"1960"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"5"|"13000"|"Visual alarms should be added to classrooms"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"1"||"All program areas and public toilet rooms are accessible"|"GOOD"|"The building presents an attractive appearance to the public "|"GOOD"|"The custodial staff maintains the building well"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"||"350000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road new Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/23/2010 4:10:49 PM| 496|"Rockville Centre UFSD"|"28022103"|"Riverside Elementary School"|"0001"|"09/14/10"|"110 Riverside Drive"|"Rockville Centre"|" 11570"|"ANNUAL"|"04/01/11"|"1918"|"23480"|"2"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"164"|"K,1,2,3,4,5"|"0"|"0"|"0"|"164"|"0"|"0"|||"12"|"9600"|"ADMIN,ART,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"28"|"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"37"|"0"||"1"|"MUN_UTILIT"|"S"|"1977"|"17"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"37"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"2005"|"15"|"0"||"0"|"S"|"2000"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"37"|"35,650"|"Provide lightning protection system, replace missing fire escape junction box cover"|"1"|"S"|"1998"|"8"|"38,500"|"Provide stage theatrical lighting/dimming system, provide additional security lighting by playground."|"1"|"1"|"S"|"2009"|"19"|"61,000"|"Provide wireless clock system, provide Smart Boards in remaning in CR's (2) & re-run CCTV feeds to Smart Boards"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"15"|"0"||"1"|"COMMON"|"S"|"1998"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"20"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Concrete joist beam slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"1"|"0"||"S"|"2008"|"20"|"0"|"Repoint masonry where required. Pain wood trim."|"1"|"MASONRY"|"S"|"1998"|"20"|"0"|"Install new concrete cap & rain diverter."|"1"|"MASONRY"|"S"|"1996"|"20"|"0"|"Repoint exterior face where required."|"S"|"S"|"0"|"1"|"1998"|"5"|"0"|"Replace old H.M. doors"|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1"|"2002"|"10"|"0"||"1"|"ALUMINUM"|"S"|"Y"|"1998"|"10"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2006"|"10"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1918"|"5"|"4,000"|"Repair leak from K room BR"|"1"|"IRON,GALVANIZED"|"S"|"1997"|"37"|"13,000"|"Provide vent caps on roof & clear vent line"|"1"|"OIL"|"S"|"2003"|"13"|"0"||"0"||||"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2006"|"36"|"0"||"1"|"S"|"2006"|"36"|"0"||"1"|"S"|"1997"|"7"|"25,750"|"Provide A/C for wire closet & custodial office/wire closet."|"1"|"S"|"1987"|"27"|"210,750"|"Provide FAI for rooms 6A,8,9A,3,1A,nurse,14,art,music,provide exhaust for CR 2 BR, refurb gym AHU, repl. exh. fan for lower level BR, refurb. fan in boiler room, provide relief air system for building"|"1"|"S"|"1997"|"27"|"103,000"|"Rebalance heat for new addition, replace old condensate receiver & replace steam traps"|"1"|"S"|"1997"|"27"|"0"||"1"|"S"|"1989"|"5"|"80,000"|"Refurbish ATC system"|"1"|"S"|"2005"|"15"|"86,500"|"Replace Simplex system & repair problematic fire alarm system"|"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"1997"|"7"|"650"|"Replace damaged gym emergency light fixture."|"0"||||"0"||"1"|"0"|"0"|"1918 original building, separate facility is designated site"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Closet & Mechanical Room"|"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"0"|"0"|"FAIR"||"662,050"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, 11772"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, P.E."|"068018"|"I ACCEPT"|12/23/2010 4:38:48 PM| 497|"Clarence CSD"|"14080106"|"LEDGEVIEW ELEMENTARY SCHOOL"|"0006"|"11/01/2010"|"5150 OLD GOODRICH ROAD"|"CLARENCE"|" 14031"|"ANNUAL"|"7/1/11"|"1960"|"60,957"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"593"|"K,1,2,3,4,5"|"0"|"1"|"0"|"549"|"0"|"44"|"CAFE,LIB"||"28"|"21,791"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"U"|"1966"|"1"|"30,000"|"INSTALL NEW BACKFLOW PREVENTOR AND ACCESSORIES."|"1"|"SITESEPT"|"U"|"1994"|"2"|"150,000"|"REPLACE SAND FILTER BED."|"1"|"S"|"2002"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"1"|"75,000"|"REPLACE ORIGINAL PARKING LOT LIGHTING AND IMPROVE SITE SECURITY LIGHTING."|"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"|"OTHER"|"CREEK"|"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"10"|"0"||"1"|"CONCRETE"|"U"|"2001"|"2"|"76,000"|"REPLACE MISC. WALKS."|"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"S"|"2001"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"0"|"S"|"2002"|"5"|"50,000"|"INSTALL ADDITIONAL RECEPTACLES IN VARIOUS CLASSROOMS AND ASSOCIATED DISTRIBUTION."|"1"|"S"|"2002"|"1"|"85,000"|"REPLACE ALL T12 FLUORESCENT, INCANDESCENT AND INTERIOR HID LUMINAIRES. UPGRADE STAGE LIGHTING SYSTEM."|"1"|"1"|"S"|"2002"|"5"|"170,000"|"UPGRADE DATA CABLING. REPLACE TELEPHONE SYSTEM. INSTALL SUB-SOUND SYSTEM IN GYM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"2001"|"2"|"185,000"|"REPLACE VAT IN CLASSROOMS."|"1"|"COMMON"|"S"|"2001"|"20"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"SLABGRADE"||"1"|"0"|"0"|"0"|"0"||"0"|"0"|"1"|"S"|"2001"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"30"|"0"||"1"|"MASONRY"|"E"|"2001"|"20"|"50,000"|"REMOVE EIXISTING OBSOLETE CHIMNEY."|"0"|||||"0"||"U"|"S"|"0"|"1"|"2001"|"2"|"141,000"|"REPLACE MISC. EXTERIOR DOORS."|"1"|"U"|"2001"|"2"|"45,000"|"REPLACE 3 EXTERIOR STAIRS."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2001"|"1"|"791,000"|"REPLACE EXISTING WINDOWS IN ORIGINAL BUILDING."|"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"|"SJ JOISTS NOTED."|"0"|"0"|"0"|"1"|"0"|"1"|"0"|"1"||"U"|"2001"|"1"|"1,010,000"|"REPLACE ROOF AT ORIGINAL BUILDING."|"1"|"PLASTIC"|"U"|"2001"|"1"|"0"|"ESTIMATE FOR SKYLIGHT REPLACEMENT IS INCLUDED IN ITEM ABOVE."|"1"|"GALVANIZED,COPPER"|"S"|"1969"|"5"|"135,000"|"REPLACE ORIGINAL BUILDING PIPING."|"1"|"IRON,GALVANIZED"|"S"|"1969"|"5"|"120,000"|"CAMARA INVESTIGATION OF DRAINAGE SYSTEM IS REQUIRED, REPLACE AS NEEDED. INSTALL ADDITIONAL ROOF DRAINS."|"1"|"NAT_GAS"|"U"|"1988"|"1"|"100,000"|"REPLACE HOT WATER HEATERS."|"1"|"S"|"1969"|"5"|"65,000"|"REPLACE ORIGINAL FIXTURES AND TRIM."|"0"||"1"|"BOILERWATE"||"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"2"|"90,000"|"INSTALL SPLIT SYSTEMS AND VENTILATION FOR WORK ROOMS."|"1"|"U"|"1960"|"5"|"675,000"|"REPLACE UNIT VENTS, AIR HANDLING UNITS, EXHAUST FANS, INTAKES AND RELIEF HOODS."|"1"|"S"|"2001"|"15"|"0"||"1"|"U"|"1960"|"5"|"20,000"|"REPLACE KITCHEN HOOD EXHAUST DUCTWORK WIH WELDING METAL."|"0"|"S"|"2001"|"5"|"0"|"REPLACE PNEUMATIC CONTROLS W/ DIGITAL CONTROLS- INCLUDED IN ITEM ABOVE."|"1"|"S"|"2002"|"5"|"95,000"|"UPGRADE FIREALARM SYSTEM TO A FULLY ADDRESSABLE SYSTEM COMPLIANT TO CURRENT CODES."|"1"|"S"|"2002"|"2"|"15,000"|"REPLACE 10+ YEAR OLD SMOKE HEADS ONLY,"|"1"|"S"|"2000"|"2000"|"0"||"1"|"U"|"2002"|"1"|"40,000"|"UPGRADE EMERGENCY LIGHTING IN VARIOUS AREAS. INSTALL"|"1"|"U"|"2002"|"1"|"60,000"|"SEGREGATE STANDBY AND EMERGENCY CIRCUITS. INSTALL NEW EXTERIOR NATURAL GAS EMERGENCY GENERATOR."|"1"|"1"|"76,000"|"INSTALL LEVER HARDWARE AND ADA TOILET AT NURSES' OFFICE."|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"0"|"0"|"1"|"FAIR"||"4,400,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville NY 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I accept"|12/23/2010 4:45:56 PM| 498|"Horseheads CSD"|"07090106"|"Center Street Elementary"|"0003"|"10/11/10"|"CENTER STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1953"|"57250"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"373"|"Pre-K,K,1,2,3,4"|"0"|"1"|"1"|"373"|"0"|"0"|||"31"|"19400"|"ADMIN,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"15"|"0"||"0"|"S"|"1987"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1995"|"30"|"0"||"1"|"S"|"1994"|"20"|"0"||"0"||||"0"||"1"|"S"|"1994"|"5"|"10000"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"136000"||"1"|"CONCRETE,ASPHALT"|"S"|"2010"|"5"|"10000"|"Major repairs and expansion done in 2010"|"1"|"E"|"2009"|"15"|"0"|"Plagrounds are fully ADA compliant for the age groups served"|"1"|"S"|"2005"|"5"|"5000"|"N"|"Field adjoin adjacent High School fields Repair erosion around perimeter of walks"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"30"|"0"||"1"|"S"|"1960"|"30"|"0"||"1"|"S"|"1960"|"30"|"0"||"1"|"S"|"2003"|"15"|"0"|"Custodial staff replaces damaged tiles on an as-needed basis"|"0"||||"0"||"1"|"S"|"S"|"1960"|"20"|"0"|"Doors in original section of ther building are reaching the end of their useful life"|"1"|"S"|"1953"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"1"|"S"|"1997"|"5"|"50000"|"Six distribution panels in the orginal section of the building should be replaced"|"1"|"S"|"1986"|"10"|"0"||"1"|"1"|"S"|"2002"|"5"|"60000"|"Obsolete phone system should be replaced with voice over IP system, PA system is adequate for 15 years"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"COMMON"|"E"|"1960"|"20"|"0"|"Existing terrazzo floors in corridors is in exxcellent condition"|"1"|"INSTRUCT"|"S"|"1953"|"15"|"0"|"Gym floor is periodically sanded and refinished to extend its useful life"|"SLABGRADE,CONCRMETAL,OTHER"|"Reinforce flat-slab concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1960"|"20"|"0"||"1"|"MASONRY"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"||"1"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"25"|"0"||"CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"10"|"0"|"Additiona drain and tapered insulation should be added to 1960 wing to correct pondng condition"|"1"|"PLASTIC"|"S"|"1992"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1960"|"20"|"0"|"Back flow preventer installed on water service and boiler make-up in 2010"|"1"|"IRON,COPPER"|"S"|"1960"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Most toilet rooms have been updated with low-flow fixtures. Single use toilet rooms should be updated"|"0"||"1"|"BOILERSTEA"||"S"|"1960"|"10"|"0"|"Boilers are original to the building. Should consider modular boilers for energy savings"|"1"|"S"|"1960"|"20"|"0"||"1"|"S"|"1998"|"10"|"0"|"DX roof-top units replaced in 1998"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2000"|"5"|"120000"|"The main panel (Notifier AFP200) is no longer made but parts are still available Visual alarms should be added to classrooms"|"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"1"||"All program areas and public toilets are ADA compliant"|"GOOD"|"The building presents a positive image to the public"|"GOOD"|"The building is well maintained"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|"WARMING"||"1"||"GOOD"||"223000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Rd New Hartford, NY 13413"|"315 738-0763"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/23/2010 5:02:48 PM| 499|"BOCES Western Suffolk"|"58930000"|"L.A. Wilson Tech. Center/N.S. Campus"|"0018"|"07/13/2010"|"152 LAUREL HILL RD "|"NORTHPORT "|" 11768"|"ANNUAL"|"05/01/2011"|"1973"|"60840"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"750"|"11,12"|"0"|"1"|"0"|"750"|"0"|"0"|||"20"|"18000"|"ADMIN,ART,COMPROOM,GUIDANCE,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,REMEDIAL,SCIENCELAB,TECHSHOP,OTHER"|"Cosmetology"|"1"|"0"|"0"|"1"|"10000"|"S"|"2000"|"2"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"12"|"0"||"1"|"SITESEPT"|"S"|"1973"|"12"|"0"||"1"|"S"|"1973"|"7"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1979"|"2"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1973"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"U"|"1988"|"1"|"132,000"|"Repair cracks and new paving at front parking area."|"1"|"CONCRETE"|"S"|"1973"|"5"|"0"||"0"||||"0"||"1"|"S"|"1973"|"8"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"13"|"0"|"Cracks at SE of 2-story wing and SE corner shops being monitored."|"1"|"S"|"1973"|"13"|"0"||"1"|"U"|"2000"|"1"|"10,000"|"Repair cracks in Mech. Rm., 2nd. floor."|"1"|"S"|"2001"|"2"|"0"||"1"|"S"|"2004"|"2"|"0"||"1"|"S"|"S"|"1995"|"7"|"0"||"1"|"S"|"1973"|"12"|"0"||"1"|"U"|"2004"|"1"|"12,000"|"New Control Panel needed."|"1"|"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"2005"|"5"|"0"||"1"|"1"|"S"|"2005"|"2"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1973"|"7"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1973"|"7"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1973"|"7"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"8"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"U"|"1973"|"1"|"57,000"|"Spandrel panels between windows need painting."|"1"|"METAL"|"S"|"1973"|"13"|"0"||"0"|||||"0"||"U"|"U"|"0"|"1"|"2005"|"1"|"16,500"|"Replace doors at shops."|"1"|"U"|"1973"|"1"|"8,000"|"Repair stone coping at planters."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"NA"|"2004"|"1"|"300,000"|"Replace all spandrel panels."|"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"U"|"1989"|"1"|"400,000"|"Replace roof over 2nd. floor and over the auto shop wing."|"1"|"PLASTIC"|"S"|"1973"|"10"|"0"||"1"|"COPPER"|"S"|"2003"|"7"|"0"||"1"|"IRON"|"S"|"1973"|"7"|"0"||"1"|"OIL"|"U"|"1973"|"1"|"2,000"|"Needs to be replaced."|"1"|"S"|"2003"|"8"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"U"|"2005"|"1"|"700,000"|"Two boilers need replacement."|"1"|"S"|"1973"|"7"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1973"|"2"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2001"|"2"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2001"|"7"|"0"||"1"|"S"|"2001"|"2"|"0"||"0"||||"0"||"1"|"S"|"2003"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS,OTHER"|"Rm. 111"|"0"|||"1"|"0"|||"0"|"1"|"0"|"0"|"1"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"1,637,500"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/23/2010 5:12:32 PM| 506|"Clarence CSD"|"14080106"|"SHERIDAN HILL ELEMENTARY SCHOOL"|"0002"|"10/26/2010"|"4560 BONCREST DRIVE EAST"|"WILLIAMSVILLE"|" 14221"|"ANNUAL"|"7/1/11"|"1959"|"74,726"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"563"|"K,1,2,3,4,5"|"0"|"1"|"0"|"519"|"0"|"44"|"CAFE,LIB"||"29"|"25,189"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1959"|"1"|"30,000"|"REPLACE BACKFLOW PREVENTOR."|"1"|"MUN_UTILIT"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"1"|"70,000"|"REPLACE ORIGINAL SITE / PARKING LIGHTING AND IMPROVE AREA SECURITY LIGHTING."|"0"||||"0"||"1"|"S"|"2002"|"5"|"25,000"|"INSTALL DRYWELL FOR EAST PARKING LOT."|"1"|"S"|"2002"|"5"|"25,000"|"INSTALL ADDITIONAL CATCH BASIS AT EAST PARKING LOT."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"2"|"230,000"|"REPLACE FRONT PARKING LOT."|"1"|"CONCRETE"|"S"|"2001"|"3"|"13,000"|"REPLACE MISC. SECTIONS OF SIDEWALKS."|"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"2001"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"S"|"2001"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"0"|"S"|"2002"|"5"|"36,000"|"REPLACE REMAINING ORIGINAL DEVICES AND ADD NEW RECEPTACLES IN ORIGINAL CLASSROOM WINGS."|"1"|"S"|"2002"|"1"|"90,000"|"REPLACE REMAINING T12 FLOURESCENT AND INCANDESCENT LIGHTING. REPLACE STAGE LIGHTING SYSTEM."|"1"|"1"|"S"|"2002"|"5"|"150,000"|"UPGRADE DATA CABLING, REPLACE PHONE SYSTEM, INSTALL SUB-SYSTEM IN MAIN GYM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"5"|"87,000"|"REPLACE CARPE IN 2001 ADDITIONS."|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"U"|"2001"|"2"|"47,000"|"REPLACE GYM FLOOR AND REFINISH STAGE FLOOR."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"20"|"0"||"1"|"MASONRY"|"S"|"2001"|"30"|"50,000"|"REMOVE OBSOLETE CHIMNEY."|"0"|||||"0"||"U"|"S"|"0"|"1"|"2001"|"3"|"35,000"|"REPLACE MISC. EXTERIOR DOORS."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"5"|"50,000"|"REPLACE ORIGINAL FIXTUES"|"0"||"1"|"BOILERWATE"||"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"2"|"30,000"|"INSTALL HVAC SYSTEM TO SPECIAL ED CLASSROOM AND AIR CONDITIONING IN ELECTRIC / LAN ROOM."|"1"|"U"|"2002"|"5"|"425,000"|"REPLACE ORIGINAL UNIT VENTILATORS, EXHAUST FANS AND RELIEF HOODS."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2001"|"5"|"0"|"REPLACE PNEUMATIC CONTROLS WITH DIGITAL CONTROLS- ESTIMATE INCLUDED IN ITEM #78."|"1"|"S"|"2002"|"5"|"55,000"|"UPGRADE CURRENT SYSTEM TO FULL ADDRESSABLE AND PROVIDE COMPLIANCE WITH CURRENT CODES."|"1"|"S"|"2002"|"2"|"12,000"|"REPLACE 10+ YEAR OLD SMOKE DETECTOR HEADS ONLY."|"1"|"S"|"2000"|"2000"|"0"||"1"|"U"|"2002"|"1"|"37,000"|"UPGRADE EMERGENCY LIGHTING IN VARIOUS AREAS."|"1"|"U"|"2002"|"1"|"40,000"|"SEGREGATE STANDBY AND EMERGENCY CIRCUTING, INSTALL OUTDOOR GENERATOR."|"1"|"1"|"5,000"|"INSTALL ADA LEVER HARDWARE AT MISC. DOORS. "|"FAIR"||"FAIR"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"0"|"0"|"1"|"FAIR"||"1,700,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main St., Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I accept"|12/24/2010 9:53:26 AM| 507|"BOCES Western Suffolk"|"58930000"|"Wilson Tech. Career Center-Building A"|"0001"|"07/15/2010"|"17 WESTMINSTER RD "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1969"|"76000"|"2"|"2"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Assistant District"|"356"|"11,12"|"0"|"1"|"0"|"356"|"0"|"0"|||"27"|"21600"|"ADMIN,ART,AV,COMPROOM,GUIDANCE,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,REMEDIAL,SCIENCELAB,TEACHRSRC,TECHSHOP,OTHER"|"Auto Shop"|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||"GOOD"||"1,067,000"|"S"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/24/2010 10:10:11 AM| 508|"Wainscott Comn SD"|"58030208"|"Wainscott Common School"|"0001"|"10/25/2010"|"47 Main Street, P.O. Box 79"|"Wainscott"|" 11975"|"ANNUAL"|"05/01/2011"|"1930"|"1145"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Storage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"1"|"641"|"NONE"||"1"|"2"|"500"|"0"|"0"|"S"|"2009"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"18"|"0"||"1"|"SITESEPT"|"S"|"2005"|"18"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1980"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1930"|"10"|"0"||"1"|"S"|"1930"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1980"|"7"|"0"||"1"|"CONCRETE"|"S"|"1980"|"5"|"0"||"1"|"S"|"2008"|"18"|"0"||"0"||||"0"|||"MASONCON"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1930"|"18"|"0"||"1"|"S"|"1930"|"2"|"1500"|"Budget to repair interior walls"|"1"|"S"|"1930"|"7"|"0"||"1"|"S"|"1930"|"2"|"1500"|"Budget for repairs"|"0"||||"0"||"1"|"S"|"S"|"1930"|"3"|"0"||"1"|"S"|"1930"|"3"|"0"||"0"||||"0"||"1"|"1"|"S"|"1930"|"3"|"0"||"1"|"S"|"1930"|"3"|"0"||"1"|"0"|"S"|"1930"|"10"|"0"||"0"||||"0"||"0"|"INSTRUCT"|"S"|"1990"|"3"|"0"||"1"|"COMMON"|"S"|"1990"|"5"|"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1930"|"3"|"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1930"|"18"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1930"|"5"|"45000"|"Budget to replace siding"|"1"|"MASONRY"|"S"|"1930"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2000"|"7"|"0"||"1"|"S"|"1930"|"3"|"500"|"Budet for repairs"|"0"|||||"0"||"1"|"WOOD,WOODCLAD"|"U"|"NA"|"1930"|"3"|"10000"|"Budget to replace windows"|"WOODONWOOD"|"OTHER"|"0"|"0"|"1"|"0"|"0"|"Old water damage around chimney"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Some water damaged areas"|"S"|"1930"|"5"|"24000"|"Budget to replace roof"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1930"|"3"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1930"|"3"|"1500"|"Budget to replace iron fitting"|"1"|"OIL"|"S"|"2007"|"17"|"0"||"1"|"S"|"1930"|"3"|"4500"|"Budget to replace select fixtures"|"0"||"1"|"BOILERWATE"||"S"|"2007"|"12"|"0"||"1"|"S"|"1980"|"3"|"0"||"1"|"S"|"2004"|"2"|"0"||"1"|"S"|"1930"|"2"|"0"||"1"|"S"|"1930"|"3"|"0"||"0"||||"0"||"1"|"S"|"1980"|"3"|"0"||"1"|"S"|"1990"|"3"|"0"||"1"|"S"|"1990"|"3"|"1000"|"Budget for requires heat detection"|"0"||||"0"||"1"|"S"|"2003"|"18"|"0"||"0"||||"0"||"0"|"0"|"0"||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"1"|"0"|"1"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"FAIR"||"1"||"1"|"1"|"0"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"89500"|"S"|"0"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Douglas Adil RA"|"021836"|"I accept"|12/24/2010 10:54:54 AM| 509|"Mohawk CSD"|"21050204"|"JARVIS JR/SR HIGH SCHOOL"|"0001"|"09/02/2010"|"28 GROVE STREET"|"MOHAWK"|" 13407"|"ANNUAL"|"10/01/2011"|"1928"|"143832"|"4"|"5"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"443"|"7,8,9,10,11,12"|"0"|"0"|"1"|"443"|"0"|"0"|||"19"|"12715"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1996"|"30"|"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"15"|"0"|"Reconstruction of Service Drive around settling catch basins completed in 2009"|"1"|"CONCRETE,ASPHALT"|"S"|"1996"|"15"|"11,000"|"Reconstruct concrete walk at main entrance"|"0"||||"0"||"1"|"S"|"1996"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1996"|"40"|"44,000"|"Water penetration at north end of building"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"20"|"86,000"|"Replace rubber treads"|"1"|"S"|"1996"|"20"|"0"||"1"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"2009"|"15"|"23,000"|"Replace fixtures in cafeteria"|"1"|"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"20"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"30"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1996"|"118,000"|"25"|"Repoint masonry (1951 wing and penthouse) "|"1"|"MASONRY,METAL"|"S"|"2009"|"10"|"40,000"|"Repoint masonry chimney"|"1"|"MASONRY"|"S"|"1996"|"20"|"0"||"S"|"U"|"0"|"0"|"1996"|"2"|"198,000"|"Replace exterior doors, frames, and hardware to improve security"|"1"|"S"|"1996"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"1"|"1"|"1"||"S"|"1996"|"5"|"1,123,000"|"Roof replacement required within 5 years"|"1"|"PLASTIC"|"S"|"1996"|"10"|"0"||"1"|"COPPER"|"S"|"1996"|"20"|"18,000"|"Replace inoperable branch valves"|"1"|"IRON,GALVANIZED"|"S"|"1996"|"20"|"0"|"Some original 1928 piping is in use"|"1"|"NAT_GAS"|"S"|"1996"|"5"|"53,000"||"1"|"S"|"2009"|"15"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2009"|"25"|"6,000"|"Add convector to 2nd floor office near elevator"|"1"|"S"|"2009"|"25"|"0"||"1"|"S"|"2009"|"25"|"0"|"Mixture of systems & equipment 1996-2009"|"1"|"S"|"1996"|"15"|"35,000"|"Provide ventilation for data/telephone rooms"|"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"|"Mixture of 1951-2009 duct work and equipment"|"1"|"S"|"2009"|"20"|"67,000"|"Replace remaining pneumatic controls"|"1"|"S"|"1996"|"10"|"112,000"|"Incomplete coverage in corridors, add A/V's in classrooms"|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1996"|"5"|"61,000"|"Replace EM battery packs"|"0"||||"0"||"1"|"1"|"497,000"|"Renovate toilet rooms in 1951 for handicapped accessibility"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2,492,000"|"S"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/24/2010 10:55:29 AM| 511|"Clarence CSD"|"14080106"|"BUS GARAGE"|"5017"|"11/02/2010"|"9825 COUNTY ROAD"|"CLARENCE CENTER"|" 14032"|"ANNUAL"|"7/1/10"|"1996"|"10500"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Garage"|"0"|||"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"0"|"0"|"2"|"20,000"|"S"|"1996"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"15"|"0"||"1"|"SITESEPT"|"U"|"1996"|"1"|"125,000"|"REPLACE SEPTIC SYSTEM."|"1"|"S"|"1996"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1996"|"15"|"50,000"|"ADD SITE LIGHTING FOR EMPLYEE PARKING."|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"5"|"50,000"|"RE-GRADE CULVERTS."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1996"|"3"|"631,000"|"REPLACE REAR PARKING LOT."|"1"|"CONCRETE"|"S"|"1996"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"30"|"0"||"0"||||"0"||"1"|"S"|"1996"|"30"|"0"||"1"|"S"|"1996"|"15"|"0"||"0"|"S"|||"0"||"1"|"S"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1996"|"5"|"40,000"|"INSTALL ADDITIONAL GFCI RECEPTACLES IN VARIOUS AREAS, SEAL CONDUITS."|"1"|"S"|"1996"|"5"|"26,000"|"REPLACE INTERIOR HID AND T12 FLUORESCENT LUMINAIRES."|"1"|"1"|"S"|"1996"|"7"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1996"|"1"|"8,000"|"REPLACE CARPET."|"1"|"COMMON"|"S"|"1996"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"30"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1996"|"10"|"0"||"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1996"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1996"|"1"|"20,000"|"INSTALL ADDITIONAL DRAINAGE TO BACK AREA BY OFFICES."|"1"|"NAT_GAS"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"0"||"1"|"FURNACE"||"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"5"|"140,000"|"REPLACE TOILET ROOM EXHAUST FANS, REPLACE INFRARED HEATING. VENTILATE BUS MAINTENANCE BAYS."|"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"U"|"1996"|"0"|"20,000"|"PROVIDE NEW FIRE ALARM SYSTEM."|"1"|"U"|"1996"|"0"|"0"|"REPLACE 10+ YEAR OLD SMOKE DETECTORS. SEE QUESTION #82."|"0"||||"0"||"1"|"NF"|"1996"|"0"|"16,000"|"REPLACE EXISTING BATTERY EMERGENCY LIGHTINGAND EXIT SIGNS. UPGRADE TO CURRENT CODE."|"1"|"U"|"1996"|"0"|"30,000"|"REPLACE SALVAGED STANDBY GENERATOR AND TRANSFER SWITCH."|"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"|||"0"|"1"||"FAIR"||"1,200,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesachitects.net"|"Scott W. Jones"|"20434"|"I accept"|12/24/2010 11:29:41 AM| 512|"BOCES Western Suffolk"|"58930000"|"Wilson Tech-Jones Hall #1-Bldg D"|"0022"|"07/15/2010"|"17 WESTMINSTER AVE "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1963"|"14000"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"180"|"10,11,12"|"0"|"1"|"0"|"180"|"0"|"0"|||"4"|"10000"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"13"|"0"||"1"|"SITESEPT"|"S"|"1963"|"8"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1981"|"13"|"0"|"Exit lights need upgrading."|"0"||||"0"||"0"||||"0"||"1"|"S"|"1963"|"1"|"30,000"|"Needs additional drainage."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1963"|"65,000"|"0"|"Resurface asphalt area behind bldg. and install new leaching pool."|"1"|"CONCRETE"|"S"|"1963"|"7"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"13"|"0"||"1"|"S"|"1963"|"13"|"0"||"1"|"U"|"1963"|"1"|"36,000"|"Repair cracks in walls as needed."|"1"|"U"|"2003"|"1"|"22,000"|"Replace ceiling tiles and grid."|"1"|"S"|"2006"|"12"|"0"||"1"|"U"|"U"|"1963"|"1"|"12,000"|"Replace some deteriorated doors."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1963"|"4"|"0"||"1"|"U"|"2002"|"1"|"9,000"|"Replace remaining original light fixtures."|"1"|"1"|"S"|"2000"|"3"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2005"|"10"|"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"9"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1963"|"13"|"0"||"1"|"MASONRY"|"U"|"1963"|"1"|"20,000"|"Repair chimney as required."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1963"|"1"|"22,000"|"Replace doors."|"1"|"U"|"1963"|"1"|"33,000"|"Replace steps."|"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1963"|"1"|"32,000"|"Replace windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"13"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1963"|"13"|"0"||"1"|"IRON"|"S"|"1963"|"13"|"0"||"0"|||||"0"||"1"|"S"|"1963"|"2"|"0"|"New fixtures needed."|"0"||"1"|"BOILERWATE"||"S"|"1963"|"1"|"500,000"|"Needs upgrading."|"1"|"S"|"1963"|"1"|"100,000"|"Needs upgrading."|"0"||||"0"||"0"|"S"|"1963"|"1"|"50,000"|"Needs upgrading."|"0"||||"0"||"1"|"U"|"1963"|"5"|"0"|"Needs upgrading."|"1"|"U"|"1963"|"1"|"45,000"|"Needs upgrading."|"1"|"U"|"1963"|"1"|"150,000"|"To be upgraded."|"1"|"U"|"1963"|"1"|"30,000"|"Upgrade."|"0"||||"0"||"1"|"S"|"2008"|"3"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,156,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/24/2010 1:16:30 PM| 513|"BOCES Western Suffolk"|"58930000"|"Wilson Tech-Jones Hall #2-Building E"|"0019"|"07/15/2010"|"17 WESTMINISTER AVE "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1973"|"10106"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"180"|"9,10,11,12"|"0"|"1"|"0"|"180"|"0"|"0"|||"3"|"8000"|"ART,AV,COMPROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"13"|"0"||"1"|"SITESEPT"|"S"|"1973"|"13"|"0"||"1"|"S"|"2008"|"19"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1973"|"13"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1973"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1976"|"1"|"95,000"|"Replace entire West parking area. "|"1"|"CONCRETE"|"S"|"1973"|"11"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1973"|"13"|"0"||"1"|"S"|"1973"|"3"|"0"||"1"|"S"|"1973"|"3"|"0"||"1"|"S"|"2003"|"6"|"0"||"1"|"E"|"2005"|"6"|"0"||"1"|"U"|"U"|"2003"|"1"|"40,000"|"Replace old doors not previously replaced."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"11"|"0"||"1"|"S"|"2003"|"6"|"0"||"1"|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1973"|"1"|"30,000"|"Replace tile as needed."|"1"|"COMMON"|"S"|"1973"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1973"|"13"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"U"|"1973"|"1"|"140,000"|"Repair cracks in stucco panels and brick above windows."|"1"|"MASONRY"|"S"|"2004"|"15"|"0"||"1"|"MASONRY"|"S"|"1973"|"3"|"0"||"U"|"U"|"0"|"1"|"2000"|"1"|"23,000"|"Need replacement at rear of building."|"1"|"U"|"1973"|"1"|"50,000"|"Replace R.R. ties retaining wall in West side."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2006"|"1"|"50,000"|"Replace windows at Southwest side."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"2"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1973"|"3"|"0"||"1"|"IRON"|"S"|"1973"|"3"|"0"||"1"|"NAT_GAS"|"E"|"2007"|"13"|"0"||"1"|"U"|"1973"|"1"|"40,000"|"Replace fixtures as needed."|"1"|"DD_MZ"|"1"|"FURNACE"||"E"|"2007"|"13"|"0"||"1"|"E"|"2007"|"13"|"0"||"1"|"E"|"2007"|"13"|"0"||"1"|"E"|"2007"|"13"|"0"||"0"||||"0"||"1"|"S"|"1989"|"3"|"0"||"1"|"E"|"2007"|"13"|"0"||"1"|"U"|"1973"|"1"|"150,000"|"Entire system needs upgrading."|"1"|"U"|"1973"|"1"|"30,000"|"Replace with new Fire Alarm System as required."|"0"||||"0"||"1"|"U"|"2003"|"1"|"25,000"|"Replace both systems."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"673,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/24/2010 2:28:27 PM| 514|"BOCES Western Suffolk"|"58930000"|"Wilson Tech-McGuire Hall #2"|"0021"|"07/15/2010"|"17 WESTMINISTER RD "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1972"|"26000"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Campus Principal"|"344"|"10,11,12"|"0"|"1"|"0"|"344"|"0"|"0"|||"7"|"5600"|"ADMIN,AV,CAFE,COMPROOM,GUIDANCE,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,MULTIPURPO,PREK,REMEDIAL,TEACHRSRC,OTHER"|"Culinary Arts"|"1"|"0"|"0"|"1"|"10000"|"U"|"1972"|"1"|"65,000"|"Replace with double wall fiberglass tank."|"1"|"MUN_UTILIT"|"S"|"1972"|"7"|"0"||"1"|"SITESEPT"|"S"|"1972"|"7"|"0"||"1"|"S"|"2006"|"16"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"12"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1972"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1972"|"1"|"55,000"|"Rear parking area needs to be resurfaced."|"1"|"CONCRETE"|"U"|"1972"|"1"|"6,000"|"Replace concrete walk in front of building."|"1"|"S"|"2003"|"2"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1972"|"10"|"0"||"1"|"S"|"1972"|"7"|"0"||"1"|"S"|"2009"|"7"|"0"||"1"|"S"|"2009"|"3"|"0"||"1"|"E"|"2006"|"11"|"0"||"1"|"S"|"S"|"2009"|"3"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2006"|"2"|"0"|"Needs upgrade of service at offices panels."|"1"|"S"|"2009"|"2"|"0"|"Need upgrading."|"1"|"1"|"S"|"2009"|"2"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"7"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"7"|"0"||"1"|"COMMON"|"S"|"2009"|"7"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1972"|"12"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"1"|"0"|"1"|"0"||"U"|"1972"|"1"|"140,000"|"Repair cracks in stucco panels, repoint brick, and replace coping."|"1"|"METAL"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"10"|"0"||"1"|"S"|"1972"|"11"|"0"|"Need some repairs at West side."|"0"|||||"0"||"1"|"ALUMINUM,VINYL,WOODCLAD"|"U"|"Y"|"2006"|"1"|"10,000"|"Window replacement at west and south sides needed."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2006"|"2"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1972"|"2"|"0"||"1"|"IRON"|"S"|"1972"|"7"|"0"||"1"|"NAT_GAS"|"E"|"2006"|"11"|"0"||"1"|"S"|"1972"|"7"|"0"|"Fixtures need upgrading."|"0"||"1"|"FURNACE"||"E"|"2006"|"11"|"0"||"1"|"S"|"1972"|"7"|"0"||"1"|"E"|"2006"|"11"|"0"||"1"|"E"|"2006"|"11"|"0"||"0"||||"0"||"1"|"E"|"2006"|"11"|"0"||"1"|"E"|"2006"|"11"|"0"||"1"|"U"|"1972"|"1"|"50,000"|"System needs upgrading."|"1"|"U"|"1972"|"1"|"0"|"Upgrade with Fire Alarm System."|"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2009"|"2"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"326,000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/24/2010 3:35:51 PM| 515|"BOCES Western Suffolk"|"58930000"|"Wilson Tech. Career Center-Building A"|"0015"|"07/15/2010"|"17 WESTMINSTER DRIVE "|"DIX HILLS "|" 11746"|"ANNUAL"|"05/01/2011"|"1990"|"14625"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"320"|"10,11,12"|"0"|"1"|"0"|"320"|"0"|"0"|||"37"|"29600"|"ADMIN,ART,COMPROOM,GUIDANCE,HLTHSUITE,HOMECAREER,SCIENCELAB,SPECED"||"1"|"0"|"0"|"1"|"10000"|"E"|"2003"|"24"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"13"|"0"||"1"|"SITESEPT"|"S"|"1990"|"24"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"13"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"14"|"0"|"See #65 for new drainage."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"7"|"0"||"1"|"CONCRETE"|"U"|"2003"|"1"|"10,000"|"Replace at ramp (phase II)."|"1"|"S"|"2002"|"6"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"46"|"0"||"1"|"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"2"|"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"13"|"0"||"1"|"E"|"2003"|"13"|"0"||"1"|"S"|"2003"|"13"|"0"||"1"|"1"|"S"|"2003"|"8"|"0"||"1"|"U"|"2003"|"1"|"12,000"|"Replace fixtures at Career Center."|"1"|"1"|"S"|"2003"|"2"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2003"|"7"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"7"|"0"||"1"|"COMMON"|"S"|"2003"|"7"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"13"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"2003"|"13"|"0"||"1"|"MASONRY"|"E"|"2003"|"13"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"12"|"0"||"1"|"U"|"2003"|"1"|"85,000"|"Needs new site drainage and regrading at South side, and repairs to North ramp at stair landing"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"12"|"0"|"New screens at phase I building."|"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"13"|"0"||"1"|"GLASS"|"S"|"2003"|"13"|"0"||"1"|"COPPER"|"E"|"2003"|"23"|"0"||"1"|"IRON"|"E"|"2003"|"23"|"0"||"1"|"OIL"|"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"12"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"12"|"0"||"1"|"U"|"2003"|"1"|"100,000"|"Roof units at Career Center need upgrading."|"1"|"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"12"|"0"||"1"|"S"|"2003"|"12"|"0"||"1"|"U"|"2003"|"1"|"50,000"|"Replace or repair system as required to function properly."|"1"|"S"|"2003"|"13"|"0"|"Upgrade."|"0"||||"0"||"1"|"S"|"2009"|"20"|"0"|"Upgrade in progress."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"257,000"|"U"|"0"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/25/2010 12:52:42 PM| 516|"BOCES Western Suffolk"|"58930000"|"Manor Plains School"|"0029"|"07/13/2010"|"200 LITTLE PLAINS RD "|"HUNTINGTON "|" 11743"|"ANNUAL"|"05/01/2011"|"1957"|"57500"|"1"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"67"|"7,8,9,10,11,12"|"0"|"0"|"0"|"67"|"0"|"0"|||"17"|"13600"|"ADMIN,CAFE,COMPROOM,GUIDANCE,GYM,HOMECAREER,KITCHEN,MULTIPURPO,REMEDIAL,SPECED,TECHSHOP,OTHER"|"Auto Shop"|"1"|"0"|"0"|"1"|"6000"|"S"|"2006"|"26"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"12"|"0"||"1"|"SITESEPT"|"S"|"1957"|"7"|"0"||"1"|"S"|"1957"|"7"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"7"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2001"|"7"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2007"|"1"|"75,000"|"Parking area at rear needs upgrading."|"1"|"CONCRETE,ASPHALT"|"U"|"2007"|"1"|"110,000"|"Replace concrete sidewalks and curbs as required."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"1990"|"2"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"8"|"0"||"1"|"S"|"1957"|"2"|"0"||"1"|"U"|"2003"|"1"|"22,000"|"Repair cracks in Gym and wherelse needed."|"1"|"U"|"2001"|"1"|"80,000"|"Replace ceilings where needed."|"1"|"E"|"2006"|"16"|"0"||"1"|"S"|"S"|"2003"|"8"|"0"||"1"|"S"|"1957"|"12"|"0"||"1"|"S"|"1957"|"4"|"0"||"1"|"1"|"S"|"2001"|"17"|"0"||"1"|"E"|"2009"|"14"|"0"||"1"|"1"|"E"|"2005"|"4"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"6"|"0"||"1"|"COMMON"|"S"|"2009"|"6"|"0"||"1"|"COMMON"|"S"|"2009"|"6"|"0"||"SLABGRADE,OTHER"|"Formed reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"2"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2008"|"10"|"0"||"1"|"MASONRY"|"U"|"1957"|"1"|"10,000"|"Repair cracks at North and South faces."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1957"|"5"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"Y"|"1957"|"1"|"770,000"|"Replace old windows with energy efficient type."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"11"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1957"|"10"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1999"|"2"|"0"||"1"|"OIL,NAT_GAS"|"E"|"2009"|"11"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"||"1"|"BOILERSTEA"||"E"|"2009"|"19"|"0"||"1"|"S"|"2009"|"19"|"0"||"0"||||"0"||"1"|"S"|"1957"|"5"|"0"||"1"|"S"|"1999"|"4"|"0"||"0"||||"0"||"1"|"S"|"2007"|"7"|"0"||"1"|"E"|"2006"|"26"|"0"||"1"|"E"|"2006"|"26"|"0"||"1"|"E"|"2006"|"2006"|"0"||"1"|"S"|"1999"|"4"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,067.000"|"U"|"1"|"Tagi A Garbizu and Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi A Garbizu"|"012741"|"I ACCEPT"|12/25/2010 1:32:18 PM| 517|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #1-ADMIN/DISTANCE LRNG"|"0038"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1967"|"9345"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"35"|"9,10,11,12"|"0"|"0"|"1"|"35"|"0"|"0"|||"3"|"2600"|"ADMIN,COMPROOM,REMEDIAL,OTHER"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"2"|"64000"|"Cost per building to install an exterior water storage tank (existing water system is inadequate)."|"1"|"SITESEPT"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1988"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"15"|"0"|"New slurry seal is needed."|"1"|"CONCRETE"|"S"|"2010"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"20"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"10"|"10,000"|"Remove and replace ceiling for 2011 Capital Project."|"0"||||"0"||"1"|"S"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1988"|"5"|"0"||"1"|"S"|"1967"|"5"|"10,000"|"Replace light fixtures at ceiling removal locations in 2011 Capital Project. "|"1"|"1"|"S"|"2002"|"10"|"5,000"|"Provide new PA System."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1997"|"10"|"40,000"|"Carpet/VCT flooring removal under abatement conditions in 2011 Capital Project. "|"1"|"INSTRUCT,COMMON"|"U"|"1997"|"10"|"0"|"Carpet/VCT flooring removal under abatement conditions in 2011 Capital Project."|"0"|||||"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"20"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1967"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1997"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"10"|"0"||"METONMET,WOODONWOOD"|"BUILTUP,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"12"|"200,000"|"Roof to be replaced in 2011 Capital Project."|"1"|"PLASTIC"|"S"|"1997"|"12"|"0"||"1"|"COPPER"|"S"|"1968"|"6"|"0"||"1"|"IRON"|"S"|"1968"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"4"|"3,000"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"1968"|"6"|"3,300"|"Replace fixture trim."|"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"|"Three (3) rooftop units and ductwork being replaced in 2011 Capital Project. "|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"512,300"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/26/2010 6:55:47 PM| 518|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #3-COSMOTOLOGY/NURSING"|"0041"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1971"|"18,726"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"108"|"9,10,11,12"|"0"|"0"|"0"|"108"|"0"|"0"|||"7"|"4272"|"ADMIN,COMPROOM,KITCHEN,RSRCEROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"2"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system is inadequate)."|"1"|"MUN_UTILIT"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1967"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"12"|"6,000"|"New slurry seal is needed."|"1"|"CONCRETE"|"S"|"1997"|"10"|"0"|"Sidewalks being replaced in 2011 Capital Project. "|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"15"|"22,000"|"Corridor wall at east side of building is not fire rated. "|"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"U"|"U"|"1971"|"5"|"42,000"|"Door and door hardware at end of useful life. "|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"1971"|"5"|"40,000"|"Replace existing with T8 fixtures in classrooms and corridors. "|"1"|"1"|"S"|"2002"|"5"|"20,000"|"Replace PA System. "|"0"||||"0"||"1"|"INSTRUCT"|"S"|"1997"|"5"|"40,000"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"10"|"0"||"1"|"COMMON"|"S"|"1971"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1997"|"5"|"10,000"|"Replace door hardware. "|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"5"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"5"|"215,000"|"Roof needs to be replaced, seams and flashing are deteriorating. "|"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"10"|"3,000"|"Not ASME, provide high efficiency condensing gas water heater. "|"1"|"S"|"1971"|"6"|"60,000"|"Replace faucet trim, replace gang toilet room fixtures. "|"0"||"1"|"OTHER"||"S"|"1991"|"5"|"150,000"|"Replace HVAC rooftop unit when roof is replaced. "|"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"8500"|"See Item #86, replace exhaust in Cosmetology Classroom. "|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"1"|"230,000"|"Make Mens and Womens toilet room accessible. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"WARMING"|"0"|"1"|"0"|"FAIR"|"Cosmetology Lab is undersized - alter to increase space - 1,800 SF"|"925,000"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 8:41:34 AM| 520|"Horseheads CSD"|"07090106"|"Sing Sing Rd Middle/Intermediate School"|"0013"|"10/11/10"|"SING SING ROAD "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/10"|"1968"|"238840"|"2"|"8"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Central Kitchen"|"1313"|"5,6,7,8"|"1"|"1"|"1"|"1313"|"0"|"0"|||"93"|"66300"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"8"|"1200000"|"Transformer pad has settled, should be replaced with next interior upgrades"|"1"|"S"|"2001"|"20"|"0"||"0"||||"0"||"1"|"S"|"2001"|"5"|"36000"|"Catchbasins should be re-set when pavement is reconstructed"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"5"|"722000"||"1"|"CONCRETE,ASPHALT"|"S"|"2010"|"5"|"20000"|"District has a plan for annual repairs to building sidewalks"|"1"|"E"|"2008"|"15"|"0"|"Building has age appropirate ADA-compliant equipment and excercise trail"|"1"|"S"|"2002"|"20"|"0"|"N"|"Consideration should be given to develop multi-purpose athletic fields for district use"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"20"|"0"|"Original fiberglas panel ceilings should be replaced (replacement tile difficult to find)"|"1"|"S"|"1968"|"10"|"0"|"Locker rooms should be reconfigured for current usage"|"1"|"S"|"S"|"2001"|"15"|"0"|"Original bulding doors reaching end of useful life. All doors have ADA compliant hardware"|"1"|"S"|"1968"|"20"|"0"||"1"|"E"|"1999"|"25"|"0"||"1"|"1"|"S"|"1968"|"5"|"300000"|"1968 building switchboard and branch circuit panles should be replaced "|"1"|"S"|"2009"|"10"|"0"|"T-8 fixtures in classrooms, T-5 in GYm & multi-purpose facility"|"1"|"1"|"S"|"2002"|"5"|"150000"|"Replace obsolete phone system with voice over IP system. PA system has 15 years remaining life"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"||"1"|"COMMON"|"S"|"1968"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1968"|"10"|"0"|"Gym floor periodically sanded and refinished to extend useful life"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"20"|"0"|"Superfical cracking noted in terrazzo finish in corridors (has not changed since last inspection)"|"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"25"|"0"||"1"|"MASONRY"|"S"|"2009"|"25"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"30"|"0"|"Building has all new aluminum entrance doors and frames"|"1"|"S"|"2001"|"20"|"0"|"Some spalling noted at base of exterior ramp due to impact damge from plowing"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"|"Roof at Kitchen area needs additional draings to elimiate ponding"|"S"|"2009"|"20"|"0"||"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2009"|"20"|"0"|"Home Ec rooms renovated in 2009, multi-purpose room added in 2001. Back flow prevention added to water service in 2010"|"1"|"IRON,COPPER"|"S"|"2001"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2008"|"25"|"0"|"New indirect heaters served by new modular boilers. Gas-fired boostere heater for Kitchen"|"1"|"S"|"2001"|"10"|"0"|"Home Ec Rooms renovated in 2009. Remainder of 1968 wing has original fixtures "|"0"||"1"|"BOILERWATE"||"E"|"2008"|"25"|"0"|"High-efficiency condensing boilers installed in 2008"|"1"|"S"|"2008"|"20"|"0"|"Mulit-purpose addition in 2001, boiler replacment in 2008 and shut-off valve in 2010"|"1"|"S"|"2003"|"15"|"0"|"RTU split system for LGI installed in 2003"|"1"|"S"|"2008"|"20"|"0"|"Gym & locvker room AHUs replaced in 2008, kitchen & library units due for replacement"|"1"|"S"|"2001"|"20"|"0"|"Multi-purpose addition in 2001"|"1"|"S"|"2001"|"20"|"0"|"Mulit-purpose room adidtion in 2001"|"1"|"E"|"2008"|"20"|"0"|"Building DDC system is on district-wide control system. On-going program of reploacment of pneumatic controls with electronic"|"1"|"S"|"1995"|"5"|"90000"|"System approaching end of useful life, no visual alarms in classrooms"|"1"|"S"|"1995"|"5"|"60000"|"Detectors above corridor ceilings nearing end of useful life"|"1"|"S"|"2005"|"2005"|"0"|"Serving grill areas at serving line, fire suppresion system in Kitchen hood replaced in 2005"|"1"|"S"|"1997"|"12"|"0"|"No emergency lighting at exterior doors"|"1"|"S"|"1968"|"5"|"125000"|"Generator is well-maintained and functioning but has reached its expceted useful life"|"1"|"1"||"All program areas are accessible and convenient accessible toilet facilities are available at all areas "|"GOOD"|"The building presents an attractive appearacne to visitors"|"GOOD"|"The custodial staff maintains the building well"|"1"|"1"|"GOOD"|"The building is well zoned to minimize noise interference to classrooms"|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"1303000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartfortd, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/27/2010 9:19:33 AM| 521|"Newfield CSD"|"61090104"|"Newfield Jr/Sr High School"|"0005"|"08/12/2010"|"247 Main Street"|"Newfield"|" 14867"|"ANNUAL"|"09/01/2011"|"1976"|"107,030"|"2"|"3"|"4"|"DISTRICT"|"INSTRUCT"||"484"|"6,7,8,9,10,11,12"|"0"|"1"|"0"|"484"|"0"|"0"|||"21"|"17,800"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1974"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"30"|"0"||"1"|"E"|"2009"|"50"|"0"|"Service was just replaced."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"20"|"0"|"Generator was replaced in 1998."|"1"|"S"|"1998"|"25"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"MUNI,SURFACEH2O"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"|"Reburbished in 1998."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"10"|"140,000"|"Bus loop remove and replace 800 SY (within 5 years). Pave gravel athletic facility parking lot. Approx. 50 spaces."|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"S"|"2009"|"10"|"100,000"|"N"|"Replace aging football goals. Replace top rail and post caps at 4' high fence around track (1,560 LF). Within 5 years, refurbish football field."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"50"|"0"||"1"|"S"|"2009"|"50"|"0"||"1"|"S"|"2001"|"40"|"0"||"1"|"S"|"2001"|"15"|"35,000"|"Tectum ceiling at 2nd floor corridor and toilet rooms has reached the end of its useful life. Remove and replace with new ACT and grid to match other areas. Approx. 4,175SF."|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"S"|"2009"|"15"|"13,000"|"Knobs in various areas need to have lever sets per ANSI requirements. The doors at Computer Lab 110 and Storage 201 need to be replaced. The sheet vinyl on the gym folding partition needs to be replaced."|"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"15"|"2,000"|"The elevator needs a pit access ladder, verify height and condition in field."|"1"|"1"|"S"|"1976"|"10"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2009"|"10"|"19,000"|"Carpet at Library 105 including periodicals, work room and storage has reached the end of its useful life and need to be removed and replaced."|"1"|"COMMON"|"S"|"2001"|"10"|"8,100"|"VCT needs to be removed and replace in Vestibule 301, Offices 115 and 124, HS Office Suite 102, Corridor 107B, Toilet 107C, 107D and Nurse's Suite. Approx. 2,700 SF."|"1"|"COMMON"|"S"|"2001"|"15"|"15,000"|"Wood floor at back of stage has rot damage from leak through exterior wall, replace area of damage."|"1"|"INSTRUCT,COMMON"|"S"|"2008"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"1"|"0"|"0"||"1"|"0"|"0"|"S"|"1992"|"50"|"52,000"|"Excavate at back wall to auditorium stage and provide new waterproofing and drainage panel. Route expansion joint at cafe and replace filler, sealant and VCT."|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"50"|"2,200"|"Repoint all masonry sills at courtyard. Repair damaged brick sill at Classroom 324."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2009"|"15"|"300"|"Exterior door at Stair 112 needs adjustment to prevent sticking."|"1"|"S"|"1998"|"10"|"14,000"|"Replace rusted railing and concrete landing at stair between HS entrance and parking lot. Replace rusted railings at stair to athletic fields."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"20"|"0"||"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"15"|"0"|"Roof over middle school is still under warranty. Revisit within 5 years."|"1"|"PLASTIC"|"S"|"2009"|"15"|"0"||"1"|"COPPER"|"S"|"1998"|"30"|"0"|"System appears to be satisfactory. Revisit in 5 years."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1998"|"30"|"68,000"|"Replace sanitary piping serving science rooms w/acid resistant piping system including an acid neutralization tank. One system to serve three rooms."|"1"|"NAT_GAS"|"S"|"2005"|"20"|"0"|"System appears to be satisfactory. Revisit in 5 years. See Item 70."|"1"|"S"|"1992"|"5"|"50,000"|"Replace outdated plumbing fixtures in Gang Toilet Rooms 103, 104, 205 and 209. 35 fixtures total. Rooms are presently ADA compliant but require fixture change and trim upgrade."|"0"||"1"|"OTHER"||"S"|"1998"|"15"|"0"|"Hot water is piped underground from the elementary school."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"5"|"100,000"|"Heat pump system serves all classrooms and office spaces. Replace 100 ton cooling tower (past useful life)."|"1"|"S"|"2009"|"25"|"400,000"|"Replace the air handling units serving the auditorium. Replace (43) classroom heat pump unit ventilators (past useful life)."|"1"|"S"|"1974"|"20"|"0"||"1"|"S"|"2009"|"25"|"0"|"The air handling units serving the duct work and accessories were replaced in the 2009 capital project. Except for the auditorium. See Item 78."|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"750"|"Add horn/strobe in Courtyard 123."|"1"|"S"|"1998"|"1998"|"0"|"Suppression system appears to be satisfactory. Revisit in 5 years."|"1"|"S"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"1"|||"GOOD"|"Circulation desks at HS Office 102 and Circulation desks at Nurse's Suite 114 have reached the end of their useful lives and need replacement.($13,750)"|"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"1"|"0"|"0"|"0"|"0"|"1"|"1"|"COMMSYS,KITCHEN,COOKING,FIREALARM,FRIDGE,SCURITYSYS"|"FULL"||"1"||"FAIR"||"1,343,030"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/27/2010 9:20:44 AM| 522|"Clarence CSD"|"14080106"|"Concession Stand-Storage"|"7015"|"12/13/2010"|"9625 Main Street"|"Clarence"|"14031"|"ANNUAL"|"7/1/11"|"2002"|"1924"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"CONCESSION STAND / STORAGE BUILDING"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"30"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"0"||||"0"||"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"30"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|"S"|"2002"|"5"|"3,000"|"UPGRADE TELEPHONE."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONMET,OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"25"|"0"||"1"|"IRON"|"S"|"2002"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"5"|"6,000"|"REPLACE BATTERY OPERATED EMERGENCY LIGHTING EQUIPMENT AND ADD EXTERIOR EMERGENCY LIGHTING."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"GOOD"||"9,000"|"S"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I accept"|12/27/2010 9:35:35 AM| 525|"Horseheads CSD"|"07090106"|"High School North Wing"|"0009"|"10/11/10"|"FLETCHER STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1953"|"150764"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"690"|"9,10,11,12"|"0"|"1"|"1"|"690"|"0"|"0"|||"56"|"28000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"20"|"0"||"1"|"S"|"1987"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"25"|"0"|"Primary switchgear new in 2009. Service and transformer new in 1987"|"1"|"S"|"1968"|"10"|"0"|"Roof leader lateral should be checked periodically for debris"|"0"||||"0"||"1"|"S"|"1987"|"5"|"50000"|"Catchbasins should be rebuilt as part of a pavement reconstruction"|"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1968"|"5"|"45000"|"Infiltation basins should be cleaned out aspart of catchbasin reconstruction work"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1987"|"5"|"325000"|"Pavement at west side (rear) failing due to previous use as main bus drop lanes"|"1"|"CONCRETE"|"S"|"2009"|"5"|"50000"|"District has annual plan for replacement of deteriorated sidewalks"|"0"||||"0"||"1"|"S"|"2004"|"5"|"233000"|"N"|"Running track surface should be renewed to prolong useful life. Baseball field irregation system shouold be improved"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"20"|"0"|"Ceiling in non-renovated areas should be replaced as part of any interior renovation project"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"S"|"2009"|"15"|"0"|"Original classroom wing doors and frames are reaching the endf of their useful life"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"1987"|"25"|"0"||"1"|"1"|"S"|"2008"|"5"|"75000"|"Replace section of exterior distribution wiring and obsolete panels in 1968 additions "|"1"|"S"|"2010"|"15"|"0"|"T-8 fixtures in classrooms and T-5 fixtures in Gym and Music rooms"|"1"|"1"|"S"|"2002"|"5"|"150000"|"Replace obsolete phone system with voice over IP system. PA system has 15 years remaining useful life"|"1"|"S"|"2009"|"20"|"0"|"Dehumidification and ventilation system replaced in 2009. Marcite finish renewed in 2009"|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"0"||"1"|"COMMON"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"10"|"0"|"Gym floor periodically saned and refinished to extend useful life"|"SLABGRADE,OTHER"|"Reinforced flat slab concrete over crawl spaces"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"30"|"0"||"1"|"MASONRY"|"S"|"2009"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"2009"|"5"|"20000"|"Original steel sash in 1956 addition at Werstling Room should be replaced"|"METONMET,CONMETMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"|"Coated-foam roof areas recoated in 2008"|"1"|"PLASTIC"|"S"|"2009"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2009"|"20"|"0"|"Needs backflow prevention on water service and boiler make-up"|"1"|"IRON,COPPER"|"S"|"2008"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||"1"|"BOILERWATE,BOILERSTEA"||"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"|"Air conditioning added to Auditorium and Music rroms"|"1"|"S"|"2008"|"20"|"0"|"Auditorium and Music room renovations"|"1"|"S"|"2008"|"20"|"0"|"Auditorium and Music room renovations"|"1"|"S"|"2008"|"25"|"0"|"Auditorium and Music room renovations"|"1"|"S"|"2008"|"20"|"0"|"Building is on district-wide control system"|"1"|"E"|"2005"|"5"|"8000"|"Existing system is a Notifier point addressible sysem with no visual alarms in classrooms"|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"2008"|"0"|"Stage area & Music Room renovations and Kitechen hood systems updated in 2006"|"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"1"||"All program areas on ground floor have on-gfrade accessible routes, second floor spaces are accessible via an elevator"|"GOOD"|"Building presents an attractive appearance to visitors"|"GOOD"|"The custodial staff does a good job of maintaining the building"|"1"|"1"|"GOOD"|"The building is well zoned to minimize noise disturbacne to classrooms."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Humidity control in locker room showers should be improved"|"1"||"1"|"1"|"0"|"0"|"0"||"0"|"0"||||"0"|"0"|"COMMSYS,HVAC,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"||"1361000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settelemt Road New Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/27/2010 10:16:11 AM| 526|"Manchester-Shortsville CSD (Red Jack"|"43110104"|"Bus Garage"|"5001"|"04/21/2010"|"1530 RTE 21"|"Shortsville"|" 14548"|"ANNUAL"|"08/01/2011"|"1969"|"9454"|"2"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Garage"|"0"|"UNGRD"|"0"|"0"|"0"||||||"0"|"0"|"OTHER"|"Bus Garage"|"1"|"1"|"1000"|"1"|"4000"|"S"|"2002"|"25"|"0"|"Gas and diesel for bus fueling NOT for heating or power."|"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"20"|"0"||"1"|"S"|"1969"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1969"|"25"|"0"||"0"||||"0"|"Sheet drain to Paddleford Brook"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"20"|"0"|"Routine maintenance required"|"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"50"|"0"||"1"|"S"|"1990"|"50"|"0"||"1"|"S"|"1990"|"50"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"|"S"|||"0"||"1"|"1"|"S"|"1990"|"20"|"0"|"400A 120/208 volt service"|"1"|"S"|"1990"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2000"|"7"|"0"||"1"|"COMMON"|"S"|"1990"|"20"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Wood deck on steel joists"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"50"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"Peeling paint on exterior walls"|"S"|"1990"|"50"|"0"||"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1990"|"2"|"14000"|"Exterior doors are rusted through, OH doors should be serviced."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"1990"|"10"|"0"|"Original building has non-thermally broken windows"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"|"Maintenance on roof"|"S"|"1990"|"5"|"100000"|"Control joints in original section"|"0"|||||"0"||"1"|"IRON"|"S"|"2008"|"28"|"0"||"1"|"IRON"|"S"|"1990"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||"1"|"FURNACE"||"S"|"1990"|"5"|"56000"|"Ventilation in maintenance and storage areas"|"1"|"S"|"1990"|"25"|"0"||"0"||||"0"||"0"|"U"|"1990"|"0"|"132000"|"Add vehicle ventilation"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1990"|"5"|"25000"|"Replace system"|"1"|"S"|"1990"|"5"|"25000"|"Replace system"|"0"||||"0"||"1"|"S"|"1990"|"5"|"5000"|"Add exterior emergency lights to comply with current codes."|"0"||||"0"||"1"|"0"|"40000"|"Toilet rooms"|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"toilet rooms"|"1"|"OTHER"|"toilet rooms"|"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"POOR"|"No ventilation in maintenance and storage areas."|"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"|||"1"||"FAIR"||"397000"|"U"|"0"|"Edge Architecture, PLLC and Energy Concepts"|"25 N. Washington Street, Rochester, NY 14445"|"585-461-3580"|"allen@edge-architecture.com"|"Allen Rossignol"|"0282951"|"I ACCEPT"|12/27/2010 10:17:16 AM| 528|"Clarence CSD"|"14080106"|"MAINTENANCE BUILDING & SPORTS CENTER"|"5005"|"11/02/2010"|"9625 MAIN STREET"|"CLARENCE "|" 14031"|"ANNUAL"|"7/1/11"|"1951"|"11150"|"1"|"1"|"0"|"DISTRICT"|"OTHER"|"Maintenance Offices & Shops"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"5"|"30,000"|"REPLACE BACKFLOW PREVENTOR AND ACCESSORIES."|"1"|"MUN_UTILIT"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"OTHER"|"BELOW"|"S"|"1988"|"5"|"10,000"|"REPLACE FEEDER FROM HIGH SCHOOL."|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1951"|"30"|"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"S"|"1996"|"6"|"0"||"1"|"S"|"1951"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"1988"|"3"|"30,000"|"REPLACE OLDER RECPTACLES, REPLACE PANELBOARDS."|"1"|"S"|"1996"|"3"|"35,000"|"REPLACE T12 FLUORESCENT LUMINAIRES AND INSTALL AUTOMATIC LIGHTING CONTROL."|"1"|"1"|"S"|"1996"|"5"|"30,000"|"UPGRADE PHONE / DATA SYSTEMS."|"0"||||"0"||"1"|"COMMON"|"U"|"1996"|"6,000"|"REPLACE CARPET."||"1"|"COMMON"|"S"|"1996"|"6"|"0"||"1"|"COMMON"|"S"|"1951"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1951"|"30"|"0"||"MASONRY"|"0"|"1"|"RUST AT BASE OF (6) INTERIOR COLUMNS"|"1"|"0"|"0"|"0"|"1"||"U"|"1951"|"1"|"115,000"|"REPLACE (6) INTERIOR COLUMNS AND MISC. MASONRY RESTORATION."|"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1996"|"2"|"15,000"|"REPLACE MISC. EXTERIOR DOORS."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"10"|"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"||"U"|"1988"|"2"|"169,000"|"REPLACE ROOF."|"0"|||||"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1990"|"10"|"0"||"1"|"IRON,PVC"|"S"|"1990"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1988"|"5"|"80,000"|"REPLACE WATER HEATER AND REMOVE STORAGE TANK."|"1"|"U"|"1967"|"5"|"30,000"|"REPLACE ORIGINAL PLUMBING FIXTURES."|"0"||"1"|"BOILERSTEA"||"E"|"2010"|"30"|"0"||"1"|"E"|"2010"|"30"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"U"|"1996"|"5"|"49,000"|"REPLACE ORIGINAL EXHAUST FANS, AND LOCKER ROOM, MAINTENANCE BAY UNIT VENTILATORS."|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"U"|"1996"|"1"|"25,000"|"INSTALL NEW FIRE ALARM SYSTEM."|"0"||||"0"||"1"|"U"|"1996"|"1996"|"30,000"|"INSTALL LED EXIT LIGHTS, INSTALL INTERIOR AND EXTERIOR EMERGENCY LIGHTING WITH BATTERY PACKS."|"0"||||"0"||"0"||||"0"||"1"|"0"|"60,000"|"INSTALL HANDICAP ACCESSIBLE TOILET ROOMS."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"|||"0"|"1"||"FAIR"||"660,000"|"U"|"0"|"Gordon W. Jones Associates, Architects"|"5757 Main Street, Williamsville, NY 14221"|"716-633-9000"|"jeff@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I Accept"|12/27/2010 10:41:17 AM| 529|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #2-AUTO BODY/AUTO TECH"|"0039"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1968"|"13275"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"57"|"9,10,11,12"|"0"|"0"|"0"|"57"|"0"|"0"|||"2"|"1550"|"RSRCEROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"15"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system inadequate). "|"1"|"MUN_UTILIT"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"3"|"0"|"New slurry seal is needed. "|"1"|"CONCRETE"|"S"|"2010"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"0"||||"0"||"1"|"S"|"1968"|"10"|"0"|"Wall finishes need to be painted."|"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"S"|"1971"|"10"|"0"||"1"|"S"|"1971"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"5"|"20,000"|"Replace outdated panels, provide rust-proof covers for receptacles in tech areas and GFI prot."|"1"|"S"|"1968"|"5"|"60,000"|"Replace existing with T8 fixtures. "|"1"|"1"|"S"|"2002"|"10"|"15,000"|"Provide new PA System. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1968"|"20"|"0"||"0"|||||"0"||"SLABGRADE,PRECAST,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"25"|"0"|"Metal siding is damaged in various locations. "|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1997"|"15"|"0"||"1"|"S"|"1968"|"10"|"0"|"Ramp being replaced under 2011 Capital Project. "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2006"|"15"|"0"||"METONMET,WOODONWOOD"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"3"|"215,000"||"0"|||||"0"||"1"|"COPPER"|"S"|"1968"|"6"|"0"||"1"|"IRON,COPPER"|"S"|"1968"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1968"|"6"|"0"||"1"|"S"|"1968"|"6"|"13,200"|"Replace lavatory trim and update toilet fixtures. "|"1"|"VAV"|"1"|"OTHER"||"S"|"2005"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"300,000"|"Replace five (5) rooftop units in Auto Lab/replace Paint Booth and heating equipment. "|"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"1983"|"1983"|"70,000"|"Replace spray booth, fire suppression system and related mechanical systems. "|"1"|"S"|"1968"|"5"|"0"||"0"||||"0"||"1"|"1"|"75,000"|"Update Toilet Rooms. "|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"396,200"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 10:46:03 AM| 530|"Newfield CSD"|"61090104"|"Newfield Elementary School"|"0001"|"08/12/2010"|"247 Main Street"|"Newfield"|" 14867"|"ANNUAL"|"09/01/2011"|"1939"|"99,538"|"2"|"3"|"4"|"DISTRICT"|"INSTRUCT"||"406"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"1"|"406"|"0"|"0"|||"23"|"17,276"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"1,000"|"S"|"1959"|"0"|"5,000"|"Fill with concrete slurry to permanently close tank per NYSDEC closure regulations in courtyard."|"1"|"MUN_UTILIT"|"S"|"1996"|"40"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"30"|"0"||"1"|"S"|"1996"|"30"|"0"|"Gas service appears to be in satisfactory condition."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"10"|"150,000"|"Remove and replace bus loop beginning at south end, including area by maintenance building and exit drive to Main St (within 5 years). Repair paving of entry drive from north end of parking lot to drive at HS/MS (within 5 years)."|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"15"|"20,000"|"Replace rusted railing at parent drop-off walk in front of school (approx. 230 LF)."|"1"|"S"|"2002"|"10"|"8,000"|"At wooden playground, remove existing pea gravel surfacing and replace with engineered wood fiber. Provide certified playground safety inspection of playgrounds over 10 years old."|"1"|"S"|"2009"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"50"|"6,000"|"Remove existing trees growing too close to buiding foundation at wing. Patch/repair exterior cracking/spauling of exposed foundation wall. Reparge exterior face of wall between boiler room and exterior stair."|"0"|"S"|"2010"|"50"|"0"||"1"|"S"|"2009"|"20"|"15,400"|"Remove/replace marble panels at Storage 104B with gypsum board including possible abatement. Replace chipped glass block at wall at Computer Lab 205. Replace walls and tile at existing shower in Faculty Toilet 103A due to moisture damage."|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"1967"|"5"|"0"||"1"|"S"|"S"|"2009"|"15"|"24,500"|"Doors at Storage 012, 018, Vestibules 72A, 73A, 105B and Corridor 76 have reached the end of their useful life and need replacement. Storage 104A door needs lever set knobs which meet ANSI requirements (ADA)."|"1"|"S"|"1962"|"50"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"1"|"S"|"1999"|"30"|"15,000"|"Replace Panels A1 and A2 (400A 208V 3 phase). Feeder is new."|"1"|"S"|"1999"|"20"|"0"||"1"|"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"5"|"2,700"|"Replace carpet in Faculty Room 12 (approx. 489 SF). Remove carpet at Pre-K 108, 109, 111 and 112. Cost for removal only. Replace with VCT to match existing. See Item 57 (approx. 862 SF)."|"1"|"INSTRUCT,COMMON"|"U"|"1996"|"7"|"26,000"|"New VCT to match existing in Pre-K 108, 109, 111 and 112. See Item 56. Remove and replace old VCT in approximately 13 rooms (approx. 6,500 SF)."|"1"|"INSTRUCT"|"S"|"2001"|"30"|"8,500"|"Remove 5" concrete curb at Boy's Toilet 13B, not ADA and replace terrazzo to match. Repair uneven terrazzo at Storage 103C. Repair/replace cracked terrazzo base at Corridor 151A. Remove and replace heaving ceramic tile at Faculty Toilet 42A."|"1"|"INSTRUCT"|"S"|"1970"|"15"|"45,000"|"Replace wood sports flooring at area under bleachers at gym/auditorium (approx. 800 SF) and refinish entire floor (approx. 5,100 SF). Pocket door needs sensor pad per code and retrofit into existing gym/auditorium system."|"SLABGRADE,CONCRMETAL,OTHER"|"concrete slab elevated"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1967"|"50"|"36,500"|"All masonry needs to be cleaned at 1919 bldg. Repoint precast base north and south sides 1919 bldg. Repair crack at brick outside of Conf 28C, Clsrm 69, Kndgrtn Repoint brick sill and lintel in Courtyard C2. Remove old sealant outside of Kndgrtn 1 and 2."|"1"|"MASONRY"|"S"|"2009"|"40"|"0"||"1"|"MASONRY"|"S"|"1940"|"50"|"0"||"S"|"S"|"1"|"1"|"2008"|"15"|"20,000"|"Replace exterior doors at Vestibules 152A, 150A and 150B. Replace two exterior hollow metal doors at Courtyard C1 and one hollow metal door at Courtyard C2."|"1"|"S"|"2009"|"15"|"3,000"|"Replace railing at stair to south of school (within 5 years). Approx. 35 linear feet. Prepare/prime and paint existing steel stair at Courtyard C1."|"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"U"|"N"|"1998"|"10"|"25,000"|"Windows at Nurse's office are in need of immediate repair. Many aluminum clad wood windows need adjusting and/or remounting within their frames. Approximately 80 windows."|"METONMET,CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"18"|"0"||"1"|"PLASTIC"|"S"|"2008"|"18"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2001"|"25"|"0"|"Domestic water system appears to be in satisfactory condition. Revisit in 5 years."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2001"|"25"|"0"|"Plumbing drainage systems appear to be in satisfactory condition. Revisit in 5 years."|"1"|"NAT_GAS"|"S"|"1996"|"9"|"0"||"1"|"S"|"2008"|"20"|"13,000"|"Replace (3) floor mounted urinals with wall hung units in Toliet 13B and repair wall and floor. Replace (2)service sinks with floor mounted mop receptors in Rooms 103B and 204C, "|"0"||"1"|"BOILERWATE"||"S"|"1998"|"22"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"1996"|"10"|"29,500"|"Replace (8) cabinet heaters in Gang Toilet Rooms 106A, 106B, 42B, 42C, 13A, 13B, 215A and 215B. Connect return duct to SA fan in Mech 209. Replace heat pump UV w/larger unit in Board Room 219."|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1999"|"10"|"750"|"Add horn/strobe in Courtyard C1."|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"||"1"||"FAIR"||"590,005"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/27/2010 10:47:37 AM| 532|"Horseheads CSD"|"07090106"|"High School South Wing"|"0001"|"10/11/10"|"CENTER STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1963"|"110800"|"2"|"4"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"689"|"9,10,11,12"|"0"|"1"|"1"|"689"|"0"|"0"|||"51"|"42800"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,LGGROUP,LIBBRARY,MULTIPURPO,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"20"|"0"||"1"|"S"|"1987"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2009"|"50"|"0"|"Primary switch, cabling and substation replaced in 2009"|"1"|"S"|"1968"|"5"|"20000"|"Catchbasins surchage drian lines after heavy rain with back-up from rainwater leaders"|"0"||||"0"||"1"|"S"|"1996"|"5"|"0"|"Catchbasins should be repaired with reconstruction of pavement subbase"|"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1968"|"5"|"450000"|"Basins should be cleaned out and enlarges as part of pavment reconstruction work"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1987"|"5"|"225000"|"Revisions to traffic patterns for buses has negatively impacted non-heavy duty pavement areas"|"1"|"CONCRETE"|"S"|"2009"|"5"|"50000"|"Sidewalks are repaired as part of the District's annual repair program on an as-needed basis"|"0"||||"0"||"1"|"S"|"2003"|"10"|"0"|"N"|"Fields are heavily used by all level of teams, irrigation would improve usefulness of soccer field"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"20"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Custodial staff replaces damaged tiles on an as-needed basis"|"1"|"S"|"2003"|"20"|"0"|"Girls locker room should be renovated to support curent program"|"1"|"S"|"S"|"2003"|"20"|"0"|"All program area doors have ADA accessible hardware"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"1"|"E"|"2009"|"35"|"0"||"1"|"S"|"2010"|"15"|"0"|"Classrooms have T-8 fixtures, gym has T-5 fixtures"|"1"|"1"|"S"|"2002"|"5"|"150000"|"Replace obsolete phone system with Voice over IP system. PA system has 15 years remaining useful life"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"15"|"0"||"1"|"COMMON"|"E"|"1963"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1963"|"15"|"0"|"Gym floor is saneded and refinished periodically to extend its useful life"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"20"|"0"||"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"30"|"0"||"1"|"MASONRY"|"S"|"1963"|"30"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"30"|"0"|"All exterior doors are new aluminum or steel doors"|"1"|"S"|"1963"|"20"|"0"||"0"|||||"0"||"0"|"ALUMINUM"|"E"|"Y"|"2003"|"30"|"0"|"Aluminum window & curtainwall system installed in 2003"|"METONMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"30"|"0"||"1"|"PLASTIC"|"S"|"2003"|"30"|"0"||"1"|"IRON,COPPER"|"S"|"1963"|"20"|"0"|"Needs backflow prevention on building service and boiler make-up"|"1"|"IRON,COPPER"|"S"|"1963"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2006"|"15"|"0"|"Previously oversized system that fed the original kichten that was removed was replaced with a high efficiency system"|"1"|"S"|"2003"|"10"|"0"|"Original fixtures not replaced in 2003 renovation should be replaced with water-saving models"|"0"||"1"|"BOILERWATE"||"S"|"1963"|"10"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"|"Classroom unit vents replaced in 2003"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Control system is part of district-wide control network"|"1"|"E"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"1"||"All program areas are accessible and ADA-compliant toilet facilities are convenient"|"GOOD"|"The building presents a positive appearance to visitors"|"GOOD"|"The building is well maintained"|"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"945000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/27/2010 11:05:47 AM| 534|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #4-CAREER MAJORS "|"0042"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1971"|"7565"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"32"|"9,10,11,12"|"0"|"0"|"0"|"32"|"0"|"0"|||"2"|"2823"|"HOMECAREER,LGGROUP,RSRCEROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"2"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system is inadequate). "|"1"|"MUN_UTILIT"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"13"|"10,000"|"New slurry seal is needed. "|"1"|"CONCRETE"|"S"|"1967"|"8"|"4,000"|"New slurry seal is needed. "|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"20"|"0"||"1"|"S"|"1999"|"13"|"0"||"1"|"S"|"1999"|"13"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"U"|"1991"|"5"|"20,000"||"1"|"S"|"S"|"1997"|"16"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1971"|"3"|"10,750"|"Replace outdated panels, provide dust-proof covers for receptacles in tech. areas."|"1"|"S"|"1971"|"5"|"30,000"|"Replace existing with T8 fixtures and provide addtional occupancy sensors."|"1"|"1"|"S"|"2002"|"2"|"20,000"|"New PA system is needed. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1991"|"5"|"0"||"1"|"INSTRUCT"|"S"|"1964"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"25"|"0"|"Weathering of brick. "|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2009"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"5"|"200,000"||"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"10"|"3,000"|"Not ASME, provide tank-less hot water heater. "|"1"|"S"|"1971"|"6"|"5,200"|"Replace faucet trim (4) and eye wash in Multi-Occupational Lab."|"0"||"1"|"OTHER"||"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"4,500"|"Add exhaust fan in mechanical room. "|"0"||||"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"1971"|"5"|"3,000"|"Provide exterior egress lighting fixtures and LED exit signs."|"0"||||"0"||"1"|"1"|"150,000"|"Make Mens and Womens Toilet rooms accessible. Add canopy for bus pick-up area. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"142,800"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 11:20:57 AM| 535|"Newfield CSD"|"61090104"|"Bus Garage"|"5002"|"08/12/2010"|"247 Main Street"|"Newfield"|" 14867"|"ANNUAL"|"09/01/2011"|"1975"|"14,867"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"bus storage and maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"1"|"11900"|"0"|"0"|"S"|"1998"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1974"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"20"|"0"||"1"|"S"|"1998"|"30"|"0"|"Gas service appears satisfactory. Revisit in 5 yesrs."|"1"|"UTIL"|"BELOW"|"S"|"2000"|"10"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"MUNI,OTHER"|"Piped to adjacent stream"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"65,000"|"Crack repair and remove and replace approx. 20% of existing asphalt paving (within 5 years)."|"1"|"CONCRETE"|"S"|"2000"|"15"|"5,000"|"Concrete apron at back side of Storage Stalls 105 is crumbling. Remove and replace with new concrete apron. Approx. 500 SF."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1974"|"30"|"0"||"1"|"S"|"1975"|"30"|"0"||"1"|"S"|"1975"|"30"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1975"|"10"|"3,500"|"Replace corroding hollow metal door to Storage Stall with aluminum frame and FRP door. Replace knobs with lever sets to meet ADA requirements at door to Service Bay 107 and two doors at Storage Mezzanine 200."|"1"|"S"|"1975"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1974"|"5"|"10,000"|"Replace 225A, 2 sect, 208V 3 phase main panel. Add (2) teleposts and 10 power outlets in office."|"1"|"S"|"1974"|"5"|"10,000"|"Reballast and relamp 100 type 12 fluorescent fixtures."|"1"|"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1975"|"5"|"0"|"Revisit within 5 years."|"1"|"COMMON"|"S"|"1975"|"30"|"0"|"See Item 60."|"0"|||||"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1975"|"30"|"20,000"|"Concrete floor at Service Bay 107 are extremely pitted and worn, replace."|"MASONRY,STEEL"|"0"|"1"||"0"|"0"|"0"|"0"|"0"||"S"|"1975"|"30"|"5,000"|"Steel columns at Wash Bay 108 are corroding slightly at the base; sandblast and protect with moisture resistant epoxy finish."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2009"|"0"|"10,000"|"Exterior hollow metal doors are starting to corrode and deteriorate. Replace with aluminum frame and FRP doors."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1975"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1975"|"10"|"112,000"|"Replace bus wash rinse arch system with a bus wash system. Rebuild bus wash rinse arch system. Include a cartridge type filtration system to reduce blockage of spray nozzles."|"1"|"IRON,COPPER"|"S"|"2000"|"35"|"0"|"Drainage system appears satisfactory. Revisit in 5 years."|"0"|"NAT_GAS"|"S"|"1999"|"15"|"0"|"Water heater appears satisfactory. Revisit in 5 years."|"1"|"S"|"1975"|"3"|"6,000"|"Replace outdated toilet room fixtures."|"0"||"1"|"BOILERWATE,OTHER"||"S"|"1974"|"10"|"0"||"1"|"S"|"1974"|"10"|"0"||"0"||||"0"||"1"|"S"|"1974"|"10"|"27,000"|"Install vehicle exhaust system in maintenance bays. Install ventilation system in maintenance bays. Install MUA transfer ducts for existing toilet rooms."|"1"|"S"|"1974"|"15"|"3,000"|"Insulate 200 ft hot water main and lateral piping."|"0"||||"0"||"0"||||"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"0"|"35,000"|"Need toilet room that meets accessibility requirements (ADA)."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"404,950"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"22982"|"I ACCEPT"|12/27/2010 11:46:59 AM| 536|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #5-TRADES/WELDING "|"0043"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1971"|"10534"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"26"|"9,10,11,12"|"0"|"0"|"1"|"26"|"0"|"0"|||"3"|"2252"|"RSRCEROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"2"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system is inadequate). "|"1"|"MUN_UTILIT"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"12"|"0"|"New slurry seal is needed. "|"1"|"CONCRETE"|"S"|"2010"|"8"|"0"|"New slurry seal is needed and some sidewalks were replaced in 2010. "|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"20"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"U"|"S"|"1971"|"1"|"6,000"|"Replace non-rated Boiler Room Door with a 2-hour rated door. Replace non-rated corridor door with a 1-hour rated assembly. "|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1971"|"2"|"10,000"|"Replace outdated panels. "|"1"|"S"|"1971"|"5"|"30,000"|"Replace existing with T8 fixtures. "|"1"|"1"|"S"|"2002"|"5"|"10,000"|"Provide PA system. "|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1997"|"5"|"0"||"1"|"INSTRUCT"|"S"|"1971"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"25"|"0"||"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"10"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2006"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"4"|"3,000"|"Not ASME, provide tank-les gas water heater. "|"1"|"S"|"1971"|"6"|"7,200"|"Replace faucet trim (4) and eye wash (2). "|"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1971"|"20"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"1"|"45,000"|"Update toilet room accessibility. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"61,200"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 11:56:54 AM| 537|"Chappaqua CSD"|"66100406"|"Douglas Grafflin Elementary School"|"0012"|"08/17/2010"|"650 King Street"|"Chappaqua"|" 10514"|"ANNUAL"|"05/01/2011"|"1962"|"96620"|"2"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"486"|"K,1,2,3"|"0"|"1"|"0"|"486"|"0"|"0"|||"23"|"22930"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,OTHER"|"Greenhouse"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"7"|"30000"|"Add RPZ backflow preventer on water service"|"1"|"MUN_UTILIT"|"S"|"1962"|"10"|"0"||"1"|"S"|"1962"|"10"|"0"|"gas for heating and cooking"|"1"|"UTIL"|"BELOW"|"S"|"2009"|"20"|"0"|"Transformer in vault and secondary service conductors to existing service equipment were replaced Replacement of service should be considered during next major addition or renovation"|"1"|"S"|"1962"|"10"|"0"|"no reported problems"|"0"||||"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"OTHER"|"daylight"|"0"|"S"|"1962"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"10"|"120000"|"Repave main driveway"|"1"|"CONCRETE,ASPHALT"|"S"|"1962"|"6"|"10000"|"Replacement of select damaged areas"|"1"|"S"|"2006"|"6"|"3750"|"Repave half of asphalt at play area"|"1"|"S"|"1962"|"6"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"6"|"0"||"1"|"S"|"1962"|"10"|"113600"|"Code upgrades Louver dampers Elevator smoke guard Wireglass storefronts to be replaced with one hour safety glazed construction"|"1"|"S"|"1962"|"10"|"0"||"1"|"S"|"1998"|"6"|"3750"|"Select ACT replacement where noted"|"0"||||"0"||"1"|"S"|"S"|"1962"|"6"|"30820"|"Replace doors to eliminate large areas of wireglass Add ADA hardware and provide positive latching at stair doors"|"1"|"S"|"1962"|"10"|"0"||"1"|"S"|"1995"|"6"|"0"||"1"|"1"|"S"|"1970"|"10"|"0"|"Replacement or upgrade of electrical distribution equipment should be considered during next major renovation or addition"|"1"|"S"|"1996"|"5"|"0"|"West gym hallway down light incandescent lamps should be replaced with energy efficient CFL lamps Gym down light fixtures are scheduled to be replaced under energy performance contract"|"1"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"tectum deck on steel joists"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"6"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"S"|"1962"|"10"|"33400"|"Replace brick in selected areas to avoid further decay Repair leaks at rooms 110 and 109"|"1"|"MASONRY"|"S"|"1996"|"10"|"0"|"Renovated when boiler burners were replaced No reported problems"|"0"|||||"0"||"S"|"S"|"1"|"1"|"2000"|"6"|"0"||"1"|"S"|"1962"|"6"|"9100"|"Add railing at ramp at exit near classroom 223"|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"2009"|"20"|"570000"|"Replace all remaning original single pane uninsulated windows Main entry storefront scheduled for replacement as part of already funded energy performance contract"|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"6"|"24750"|"Cost for recoating of flashing and infrared moisture investigation and skylight fall protection"|"1"|"PLASTIC"|"S"|"1998"|"6"|"0"||"1"|"COPPER"|"U"|"1962"|"0"|"300000"|"Leaks and broken pipes reported throughout distribution system Major repairs are required"|"1"|"IRON,COPPER"|"S"|"1962"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2004"|"6"|"0"|"Gas fired water heater was installed in 2004 The indirect heater is functional but nearing end of its expected useful life"|"1"|"S"|"1990"|"10"|"0"|"Plumbing fixtures are replaced by building custodial staff as they fail"|"0"||"0"|"BOILERWATE"||"S"|"1996"|"0"|"0"|"Boilers are original and scheduled for replacement under already funded energy performance contract Burners are satisfactory"|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"7"|"0"|"No central cooling system Split system and window units in some areas"|"1"|"S"|"1962"|"7"|"0"||"1"|"S"|"1962"|"6"|"0"||"1"|"S"|"1962"|"5"|"0"||"1"|"S"|"1962"|"0"|"0"|"Pneumatic control system is past useful life and is scheduled to be replaced with new DDC control system under already funded energy performance contract"|"1"|"S"|"1999"|"10"|"120000"|"Visual alarm devices in classrooms as required by latest NYS building code should be installed within the next year"|"1"|"E"|"1999"|"10"|"0"||"1"|"S"|"1999"|"1999"|"15000"|"Stove in faculty lounge needs a hood and Ansul chemical system"|"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Offices 109 and 110"|"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"0"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"||"1"||"GOOD"||"1380420"|"U"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/27/2010 11:57:39 AM| 541|"Horseheads CSD"|"07090106"|"Big Flats Elementary"|"0006"|"10/11/10"|"MAPLE STREET "|"BIG FLATS "|" 14814"|"ANNUAL"|"8/01/11"|"1956"|"57580"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"412"|"Pre-K,K,1,2,3,4"|"0"|"1"|"1"|"412"|"0"|"0"|||"36"|"28000"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2009"|"25"|"0"|"backflow prevention added in 2010"|"1"|"MUN_UTILIT"|"E"|"2010"|"30"|"0"|"Building connected to new muncipal system in 2010"|"1"|"S"|"1956"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"5"|"25000"|"Service is original to building, consider upgrsade within five years"|"1"|"S"|"1960"|"20"|"0"||"0"||||"0"||"1"|"S"|"2005"|"5"|"18000"|"Catchbasinsshould be upgraded with pavement renovations"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"156000"|"Staff parking area, part of the orginal construction is fialing, curbing required in several areas to stablize shoulders "|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"5"|"10000"|"Sidewalks repaired as part of the District's annual repair program"|"1"|"S"|"2003"|"15"|"0"|"ADA-compliant aparatus is available for all age groups served"|"1"|"S"|"2005"|"5"|"8000"|"N"|"cracking in tennis court surface needs repair to extend useful life of surface."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"1"|"S"|"1960"|"30"|"0"||"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"1999"|"10"|"0"|"Custodial staff replaces damaged tiles on an as-needed basis"|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"S"|"1968"|"10"|"0"|"Doors in original 1956 areas of building reaching the end of their useful life."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"5"|"48000"|"Six orignal panel boards in the 1956 wings of the building should be repalced"|"1"|"S"|"1997"|"15"|"0"|"T-8 fixtures in clssrooms, T-5 fixtures in gym"|"1"|"1"|"S"|"2002"|"5"|"70000"|"Replace obsolete phone system with voice over IP system. PA sysatem has 15 years of remaining useful likfe."|"0"||||"0"||"1"|"COMMON"|"S"|"1999"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"20"|"0"||"1"|"COMMON"|"E"|"1960"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"10"|"0"|"Gym floor recieves periodic sanding and refinishing to extend useful life."|"SLABGRADE,OTHER"|"Reinforced flat slab concrete over crawl spaces"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"5"|"5000"|"Repair spalled concrete at cafeteria exit door"|"1"|"MASONRY"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"5"|"15000"|"Oldest original wing metal doors should be replaced."|"1"|"S"|"2003"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"|"All wings of building now have new windows"|"METONMET,CONMETMET,OTHER"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1965"|"20"|"0"|"Back flow prevention added to main service entrance and boiler make-up in 2010."|"1"|"IRON,COPPER"|"S"|"1965"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"20"|"0"||"1"|"S"|"2008"|"10"|"0"|"Original 1965 wing fixtures should be replaced with water saving fixtures as part of the next interior renovation"|"0"||"1"|"BOILERSTEA"||"S"|"1960"|"10"|"0"|"Boiler No. 2 was installed with 1960 addition."|"1"|"S"|"1960"|"20"|"0"|"Work part of Bioler No. 2 installation"|"0"|"S"|"2004"|"20"|"0"|"DX RTU's replaced in 2004"|"1"|"S"|"2004"|"10"|"0"|"Gym & Cafeteria AHU's replaced, B-wing unit vents need replacement"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"|"Building is on the district's computer controlled network. System is updated with added control points periodically."|"1"|"S"|"2004"|"15"|"120000"|"Visual alarms should be added to classrooms"|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"1"||"All program areas are accessible"|"GOOD"|"The building presents a positive appearance to visitors"|"GOOD"|"The building is well maintained"|"1"|"1"|"GOOD"|"The building is well zoned to minimize noise in classrooms"|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"GOOD"||"340000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/27/2010 12:19:24 PM| 542|"Greenwich CSD"|"64080104"|"Bus Garage"|"5001"|"04/08/2010"|"GRAY AVE "|"GREENWICH "|" 12834"|"ANNUAL"|"01/01/2011"|"1954"|"8625"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"bus maintenance and /or storage"|"0"||"0"|"0"|"0"||||||"0"|"0"|||"1"|"2"|"7000"|"1"|"2000"|"S"|"2009"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1999"|"20"|"0"||"0"|||||||"0"||"1"|"U"|"1999"|"3"|"32,800"|"Single drywell in parking lot overflows."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"15"|"50,600"|"Typically satisfactory (15) - raise paving at all garage doors to eliminate excessive lip (1)."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"S"|"1954"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"U"|"1988"|"3"|"201,800"|"Replace vehicle lift and pit - cover removes manually and is a safety hazard."|"1"|"0"|"U"|"1999"|"3"|"19,400"|"Replace electric panels, provide more capacity and install 4 block heaters in the parking lot."|"1"|"S"|"1988"|"10"|"0"||"1"|"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1988"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1988"|"20"|"0"||"1"|"METAL"|"S"|"2000"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1954"|"3"|"24,700"|"6 - 6' x 6' / 2 - 2' x 4'-8" / 2 - 6' x 10', asbestos caulking removal NOT included."|"METONMET,OTHER"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"0"||"U"|"1995"|"3"|"205,500"|"Sprayed Polyurethane Foam (SPF) over asbestos containing built-up asphalt and EPDM over asbestos containing built-up asphalt."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1988"|"10"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1988"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2006"|"10"|"0"||"1"|"S"|"2010"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2000"|"10"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"0"|"0"|"49,300"|"Handicap accessible men's & women's toilet facilities (3 years) and automatic door operation required (3 years)."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"||"POOR"||"584,100"|"U"|"1"|"St. John Architects"|"172 Ridge Street, Glens Falls, NY 12801"|"518-223-0225"|"sjarch@roadrunner.com"|"Samuel D. St. John"|"019740"|"I ACCEPT"|12/27/2010 12:20:48 PM| 543|"Chappaqua CSD"|"66100406"|"Seven Bridges Middle School"|"0036"|"08/27/2010"|"222 Seven Bridges Road"|"Chappaqua"|" 10514"|"ANNUAL"|"05/01/2011"|"2003"|"159170"|"3"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"625"|"5,6,7,8"|"0"|"1"|"0"|"625"|"0"|"0"|||"24"|"19240"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED"||"1"|"0"|"0"|"1"|"15000"|"S"|"2003"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"18"|"0"||"0"||||"0"||"1"|"MUNI,SURFACEH2O"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"|"Needs to be restored to original layout a series of three ponds"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2003"|"8"|"810000"|"Allowance to pave item 4 parking lot with asphalt"|"1"|"CONCRETE,ASPHALT"|"U"|"2003"|"0"|"10000"|"Repair sidewalk areas that are broken"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"15500"|"Allowance to replace aluminum panel at each stairwell where kids have kicked them in and to add expansion joint with aluminum cover at lunch line area of cafeteria"|"1"|"S"|"2003"|"7"|"2000"|"Allowance to replace several tiles in rooms 311 320 and 322"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"S"|"2003"|"15"|"5400"|"Replace doors on room 221 and boys toilet room 026"|"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"|"Scheduled energy performance contract will reportedly correct issue with ballasts and lamps burning out on third floor"|"1"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2003"|"6"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"20"|"0"||"1"|"COMMON"|"S"|"2003"|"30"|"15000"|"Allowance for crack filler and stabilizationn on auditorium tiers"|"1"|"COMMON"|"S"|"2003"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"1"|"0"|"1"|"0"||"S"|"2003"|"12"|"12000"|"Allowance to investigate and correct window area leaks at room 310 Common and Cafeteria"|"1"|"METAL"|"S"|"2003"|"15"|"0"|"No reported problems"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"13"|"0"||"1"|"S"|"2003"|"7"|"150000"|"Allowance to add a canopy at second drop off and pick up area to shelter students"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"23"|"3500"|"Replace one 5x7 area of glazing at Commons where seal is failed"|"METONMET"|"BUILTUP,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"1"||"S"|"2003"|"6"|"46800"|"Allowance to investigate and correct leaks in several specific areas"|"1"|"PLASTIC"|"S"|"2003"|"6"|"0"||"1"|"COPPER"|"S"|"2003"|"20"|"0"||"1"|"IRON"|"S"|"2003"|"20"|"0"||"1"|"OTHER"|"S"|"2003"|"15"|"0"|"PUI water heaters No reported problems"|"1"|"S"|"2003"|"10"|"0"||"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"|"Building is served by several split systems and rooftop air handling units for cooling"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"|"DDC system and BMS"|"1"|"S"|"2003"|"15"|"120000"|"Allowance to add visual alarm devices in classrooms to address recent code updates"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"1"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"||"1"||"GOOD"||"1340200"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/27/2010 12:28:27 PM| 545|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #6-HEAVY EQUIPMENT "|"0051"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1971"|"7662"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"58"|"9,10,11,12"|"0"|"0"|"0"|"58"|"0"|"0"|||"3"|"2200"|"RSRCEROOM,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1971"|"2"|"64,000"|"Cost per building to install at exterior water storage tank (existing water system is inadequate). "|"1"|"MUN_UTILIT"|"S"|"1971"|"2"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"0"|"New slurry seal is needed. "|"1"|"CONCRETE"|"S"|"1971"|"5"|"0"|"New slurry seal is needed on blacktop. "|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"1"|"S"|"1971"|"10"|"0"||"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"U"|"1971"|"2"|"5,000"|"Replace lockers located in the Shop (approximately 24 units). "|"1"|"S"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1971"|"2"|"12,500"|"Replace outdated panels. "|"1"|"S"|"1971"|"5"|"30,000"|"Replace existing with T8 fixtures. "|"1"|"1"|"S"|"2002"|"10"|"10,000"|"Replace PA System. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1993"|"5"|"0"||"1"|"INSTRUCT"|"S"|"1971"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Face of brick is wearing."|"S"|"1971"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1997"|"10"|"0"||"1"|"S"|"2010"|"10"|"0"|"Replace railing on loading dock stair-southwest side of building(replaced in 2010)."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"10"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"8"|"100,000"||"0"|||||"0"||"1"|"COPPER"|"S"|"1971"|"6"|"0"||"1"|"IRON"|"S"|"1971"|"6"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"10"|"3,000"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"1971"|"10"|"3,200"|"Replace faucet trim (4) locations."|"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"1971"|"5"|"10,000"||"0"||||"0"||"1"|"1"|"12500"|"Make Toilet Room accessible. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"210,200"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 1:15:21 PM| 546|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #7-CULINARY ARTS "|"0030"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1988"|"5000"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"51"|"9,10,11,12"|"0"|"0"|"1"|"51"|"0"|"0"|||"1"|"1000"|"KITCHEN,MULTIPURPO"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"2"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system is inadequate). "|"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1988"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"7"|"0"|"New slurry coat seal is needed."|"1"|"CONCRETE"|"S"|"1988"|"7"|"0"|"New slurry coat seal is needed."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"40"|"0"||"1"|"S"|"1988"|"40"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"U"|"U"|"1988"|"15"|"8,000"|"Double doors between kitchen and lobby and kitchen and cafeteria are not rated assemblies. Remove existing doors and frames and replace with 1-hour rated doors and frames. "|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"5"|"22,000"|"Replace existing with T8 fixtures. "|"1"|"1"|"S"|"2002"|"10"|"10,000"|"Provide new PA system. "|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"2002"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"25"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1988"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1988"|"15"|"0"||"1"|"IRON"|"S"|"1988"|"15"|"15,000"|"Provide grease trap. "|"1"|"NAT_GAS"|"S"|"2003"|"10"|"12,500"|"Not ASME, provide high efficiency condensing gas water heater. "|"1"|"S"|"1988"|"15"|"8,200"|"Replace faucet trim (4) locations/provide grease trap for three compartment sink. "|"0"||"1"|"OTHER"||"S"|"2003"|"20"|"0"||"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"100,000"|"Replace kitchen hood to cover all gas equipment in kitchen. Replace all rooftop equipment. "|"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"1988"|"5"|"3,000"|"Provide exterior egress lighting fixtures and LED exit signs."|"0"||||"0"||"1"|"1"|"1,000"|"Add grab bars in toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"FULL"|"0"|"1"|"0"|"FAIR"||"309,400"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 1:48:53 PM| 547|"Horseheads CSD"|"07090106"|"Broad Street Elementary"|"0004"|"10/11/10"|"BROAD STREET "|"HORSEHEADS "|" 14845"|"ANNUAL"|"8/01/11"|"1960"|"60600"|"1"|"2"|"0"|"LSD_NDE"|"OTHER_ORG"||"0"||"0"|"0"|"0"||||||"29"|"25160"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"20"|"0"||"1"|"S"|"1960"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"5"|"40000"|"Entrance should be upgraded with any renovation project"|"1"|"S"|"1960"|"10"|"0"||"0"||||"0"||"1"|"S"|"1960"|"5"|"18000"|"System should be imnproved to minimize ponding"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1960"|"5"|"43000"||"1"|"CONCRETE,ASPHALT"|"S"|"1991"|"5"|"6000"|"Provide ramped sidwalk at gym exit door discharges (two locations)"|"1"|"S"|"1990"|"10"|"0"|"Aparatus shouold be upgraded to age appropriate use once the long term usage is established"|"1"|"S"|"1990"|"5"|"120000"|"N"|"Consider irregation system for softball field to enhance usage."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"30"|"0"||"1"|"E"|"1960"|"30"|"0"||"1"|"E"|"1960"|"30"|"0"||"1"|"S"|"1991"|"10"|"0"|"Wall surfaces in locker rooms should be refinished."|"0"|"S"|"1991"|"10"|"0"||"1"|"S"|"S"|"1960"|"10"|"0"|"Some interior doors have missing face veneer"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1992"|"5"|"85000"|"Distribution panels in orginal portion of building should be replaced"|"1"|"S"|"1997"|"15"|"0"||"1"|"1"|"S"|"1985"|"5"|"125000"|"Oboslete phone system should be replaced with Voice over IP system with any interior renovation work."|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1960"|"10"|"0"|"All original building floor tile is asbestos-containing and should be removed as part of any interior renovations."|"1"|"COMMON"|"E"|"1960"|"20"|"0"||"1"|"INSTRUCT"|"U"|"1960"|"10"|"0"|"Gym floor receives periodic sanding and refinishing to extend service life."|"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"30"|"0"||"MASONRY,WOOD"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"S"|"1992"|"5"|"10000"|"Original stone-faced panels at addition link have areas of delamination"|"1"|"MASONRY"|"S"|"1960"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1960"|"10"|"0"|"Exterior doors should be replaced with any interior renovation project."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"20"|"0"||"WOODONWOOD,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"1"|"PLASTIC"|"S"|"2003"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1992"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1992"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"||"1"|"S"|"1992"|"5"|"75000"|"Original 1960 building fixtures should be replaced as part of any interior renovation."|"0"||"1"|"BOILERSTEA"||"S"|"1960"|"10"|"0"||"1"|"S"|"1960"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"|"RTU with DX coils replaced in 2003."|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Control sysatem is part of the District-wide control network."|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"1991"|"5"|"2000"|"Additional battery packs should be added to extend coverage."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"|"Building is well maintained"|"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"GOOD"||"447000"|"S"|"0"|"McDonald and Monterose Architects LLP"|"4305 Middle Settlement Road New Hartford, NY 13413"|"315 738-7063"|"mcdmont@centralny.twcbc.com"|"David McDonald"|"013010"|"I ACCEPT"|12/27/2010 1:52:43 PM| 548|"Somers CSD"|"66210106"|"Primrose Elementary"|"0002"|"08/23/2010"|"110 Primrose Street"|"Lincolndale"|" 10540"|"ANNUAL"|"08/01/2011"|"1955"|"95285"|"1"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"742"|"K,1,2"|"0"|"1"|"0"|"742"|"0"|"0"|||"38"|"33979"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10000"|"S"|"1998"|"10"|"0"|"New double walled tank installed in 1998"|"1"|"WELL"|"S"|"1955"|"0"|"350000"|"Well pumps and hydropneumatic tanks are functioning past their expected useful life Level controls and air compressors are functioning"|"1"|"SITESEPT"|"S"|"1955"|"20"|"0"||"1"|"S"|"2000"|"7"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1955"|"7"|"0"|"Past phase issue damaged some equipment and should be reviewed with the utility company"|"1"|"S"|"2000"|"15"|"7000"|"Reconnect one leader and regrade south A wing"|"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"SURFACEH2O,OTHER"|"daylight"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"5"|"48500"|"Selective repaving and preventative maintenance"|"1"|"CONCRETE,ASPHALT"|"U"|"2002"|"5"|"24000"|"Specific areas need replacement"|"1"|"S"|"2010"|"5"|"0"||"1"|"S"|"1955"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"20"|"0"||"1"|"S"|"2000"|"15"|"107100"|"Replace glass lites in corridor walls with safety glass"|"1"|"S"|"2000"|"15"|"5500"|"Expansion joint and miscellaneous repairs"|"1"|"S"|"2000"|"5"|"9580"|"Replace ceilings in select areas"|"0"||||"0"||"1"|"S"|"S"|"1999"|"10"|"24500"|"Add electro magnetic hold opens on select doors and ADA hardware upgrade"|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"1"|"S"|"2000"|"12"|"0"||"1"|"S"|"2006"|"20"|"3750"|"2250 for ballast replacements in classrooms with flickering lights 1500 for additional fixtures in E wing corridor where light levels appeared low"|"1"|"1"|"S"|"2007"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"3"|"15530"|"Replace carpet in corridors of several wings"|"1"|"INSTRUCT,COMMON"|"S"|"1998"|"7"|"0"||"1"|"COMMON"|"S"|"1998"|"7"|"0"||"1"|"COMMON"|"S"|"1955"|"12"|"0"||"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"20"|"1400"|"Allowance for repair of cracked wall top"|"1"|"MASONRY"|"S"|"1955"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1989"|"5"|"0"||"1"|"S"|"2000"|"2"|"29160"|"Replace cracked steps Add guard rail Replace wood ramp"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1989"|"5"|"30000"|"Replace selected rusting spandrel panels"|"CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2000"|"10"|"5000"|"Fascia section replacement"|"0"|||||"0"||"1"|"COPPER"|"S"|"1955"|"15"|"0"||"1"|"IRON"|"S"|"1955"|"15"|"0"||"1"|"OIL"|"E"|"2008"|"7"|"0"||"1"|"S"|"1995"|"4"|"16800"|"Replace sinks and counters in rooms D2 D3 and D4 Miscellaneous fixtures replaced as necessary"|"0"||"1"|"BOILERSTEA"||"S"|"1962"|"7"|"250000"|"Allowance to refurbish three original steam boilers as per Owner request"|"1"|"S"|"1998"|"12"|"0"||"1"|"U"|"2000"|"3"|"250000"|"Controls for packaged rooftop HVAC units do not work well Library and Computer Rm units are undersized and unreliable"|"1"|"S"|"2000"|"2"|"542000"|"Many original classrooms have only operable windows for ventilation and should be upgraded to include UVs for ventilation and gymnasiums do not appear to have ventilation"|"1"|"S"|"1955"|"3"|"78640"|"Replace steam traps and Dar grilles at damaged fin tube enclosures Balance of original steam traps are operating beyond their expected useful life"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"7"|"200000"|"Electric controls on packaged rooftop units are working poorly and need continual service Pneumatic systems are functioning but are beyond expected useful life"|"1"|"S"|"2008"|"12"|"40000"|"There are no notifcatoin devices in clasrooms and existing notification devices are bell strobes and should be updated during next major renovation"|"1"|"S"|"2008"|"5"|"50000"|"Existing initiation devices should be updated during next major renovation"|"1"|"S"|"2000"|"2000"|"0"|"Kitchen hood fire suppression system are working well No sprinkler system in building"|"1"|"S"|"2000"|"5"|"0"|"Older wing of building contains non energy efficient exit signs which are working properly but should be replaced during next major renovation"|"0"||||"0"||"1"|"1"|"20000"|"Provide ADA access to stage via lift"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS,OTHER"|"Cafeteria"|"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"|"All responses based on visual inspection and do not include testing"|"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"||"FAIR"||"2214960"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"ekaeyer@kgdarchitects.com"|"Erik A Kaeyer AIA LEED AP"|"028179"|"I ACCEPT"|12/27/2010 1:55:05 PM| 552|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #11-MAINTENANCE "|"3036"|"05/17/2010"|"1126 BALD HILL RD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1988"|"2140"|"1"|"2"|"1"|"DISTRICT"|"OTHER"||"0"|||"0"|"0"||||||"0"|"0"|"OTHER"|"Maintenance Shop"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"2"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system is inadequate). "|"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1988"|"25"|"0"||"0"||||"0"||"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"2"|"0"|"New slurry seal is needed."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"30"|"0"||"1"|"S"|"1988"|"30"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"U"|"U"|"1988"|"10"|"0"||"1"|"S"|"1988"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1988"|"5"|"1,000"|"Provide GFI protection as required. "|"1"|"S"|"1988"|"5"|"5,000"|"Replace existing with T8 fixtures. "|"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1988"|"20"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"15"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"1"|"0"|"0"|"0"||"S"|"2010"|"10"|"0"|"Masonry wall on east side repaired 2010 by School District. "|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1988"|"8"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1988"|"8"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"8"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1989"|"15"|"0"||"1"|"IRON"|"S"|"1989"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"5"|"3,000"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"1988"|"15"|"1,600"|"Replace faucet trim (2) locations. "|"0"||"1"|"OTHER"||"S"|"1988"|"5"|"10,000"|"Replace furnace. "|"1"|"S"|"1989"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1989"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"1"|"1"|"0"|"0"|||"0"|"1"|"0"|"FAIR"||"14,600"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 2:26:55 PM| 557|"Somers CSD"|"66210106"|"Somers Middle School"|"0001"|"08/19/2010"|"250 Route 202"|"Somers"|" 10589"|"ANNUAL"|"08/01/2011"|"1936"|"144527"|"3"|"8"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"868"|"6,7,8"|"0"|"1"|"0"|"868"|"0"|"0"|||"24"|"39234"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10000"|"S"|"1995"|"15"|"0"|"Tank level and leak controls are functioning"|"1"|"WELL"|"S"|"1961"|"5"|"110000"|"Well pump and buried 10000 gallon hydropneumatic tank are functioning past expected useful life"|"1"|"SITESEPT"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"10"|"0"|"A 500 gallon buried LPG tank serves cooking and kitchen only"|"1"|"UTIL"|"BELOW"|"E"|"2008"|"20"|"0"||"1"|"S"|"2006"|"30"|"0"||"0"||||"0"||"1"|"S"|"2006"|"30"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"0"||"1"|"CONCRETE,ASPHALT,OTHER"|"S"|"1998"|"5"|"3600"|"Minor patching required"|"0"||||"0"||"1"|"S"|"1958"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"15"|"6840"|"Scheduled replacements"|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"S"|"2008"|"16"|"65000"|"Doors on third floor are in need of replacement throughout and doors on second floor need hardware upgrades"|"1"|"S"|"2008"|"21"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"1"|"S"|"2008"|"10"|"0"|"Areas nearing indadequacy are the old eighth grade wing and third floor"|"1"|"S"|"2008"|"10"|"0"|"Areas nearing indadequacy are the old eighth grade wing and third floor"|"1"|"1"|"S"|"2000"|"10"|"0"|"Classroom and corridor devices have not been updated and appear to be deficient of speakers There are some wiring issues which may limit the functionality of the system"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"20"|"0"||"1"|"INSTRUCT"|"E"|"2008"|"15"|"0"||"1"|"COMMON"|"E"|"2008"|"30"|"0"||"1"|"INSTRUCT"|"S"|"1998"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"25"|"0"||"0"|"MASONRY"|"S"|"1958"|"20"|"0"||"1"|"MASONRY"|"S"|"1936"|"5"|"30000"|"Parapets in 1936 part of building adjacent to cupola are starting to lean and brick is crumbling with leaks starting School has been making repairs as necessary"|"S"|"S"|"1"|"1"|"1998"|"10"|"0"||"1"|"S"|"1998"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"Y"|"2008"|"25"|"175000"|"Windows in 1950 portion of building are at end of their useful life and in need of replacement"|"METONMET,WOODONMET,CONMETMET"|"SINGLEPLY,BUILTUP,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"Leaking at 1936 portion"|"S"|"2008"|"21"|"110000"|"Balance of ballast membrane roof of 1936 portion at end of useful life and in need of replacement"|"0"|||||"0"||"1"|"COPPER"|"S"|"2008"|"15"|"0"||"1"|"IRON"|"S"|"2008"|"20"|"0"||"1"|"OIL,ELECTRIC"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"24000"|"Most fixtures in the old building are original and while working well are at the end of their expected useful life"|"0"||"1"|"BOILERWATE,BOILERSTEA"||"S"|"2008"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"30000"|"Exhaust fans in old building appear to be original but are functioning Some problems with controls of the original exhaust fans"|"1"|"S"|"2008"|"5"|"75000"|"Most steam traps piping and specialties associated with original steam plant are at the end of their expected useful life Reports of steam returning to condensate receiver tank indicate failure of some traps "|"1"|"S"|"2008"|"15"|"40000"|"Any supply or return ductwork not replaced since 2000 is near end of its expected lfie Exhaust ductwork through roof appears to be original and is near end of its expected life"|"1"|"S"|"2008"|"10"|"300000"|"Control systems are pneumatic and electric Set points and balance levels at dampers fans and ventilators must be reset daily"|"1"|"S"|"2008"|"5"|"150000"|"Existing zones are large and cause confusion when in alarm Notification and initiator devices are deficient System must be upgraded in next 5 years"|"1"|"S"|"2008"|"5"|"0"||"1"|"S"|"1990"|"1990"|"0"|"Inspected yearly and maintained"|"1"|"S"|"2000"|"5"|"0"||"1"|"E"|"2008"|"25"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"HVAC,LIGHTING"|"FULL"|"1"|"1"||"GOOD"|"Major addition in 2008"|"1134440"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"ekaeyer@kgdarchitects.com"|"Erik A Kaeyer AIA LEED AP"|"028179"|"I ACCEPT"|12/27/2010 3:24:43 PM| 560|"Rochester City SD"|"26160001"|"Dr. Martin Luther King School #9"|"0009"|"08/04/2010"|"485 CLINTON AVENUE "|"ROCHESTER "|" 14605"|"ANNUAL"|"06/01/2011"|"1975"|"85796"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"679"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"0"|"679"|"0"|"0"|||"43"|"35524"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,PREK"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1993"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1975"|"25"|"0"||"1"|"S"|"1975"|"45"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"15"|"0"|"pad mounted transformer"|"1"|"S"|"1975"|"25"|"0"||"0"||||"0"||"1"|"S"|"1975"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1975"|"3"|"237750"||"1"|"CONCRETE"|"U"|"1975"|"1"|"78000"|"replaced heaved and cracked sidewalks"|"0"||||"0"||"0"||||"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1975"|"45"|"0"|"in north stair (#5) monitor cracks "|"1"|"S"|"1975"|"45"|"0"||"1"|"S"|"1994"|"45"|"0"||"1"|"S"|"2001"|"5"|"0"||"1"|"S"|"1975"|"5"|"0"||"1"|"S"|"S"|"1975"|"5"|"0"|"provide 1.5 door in boiler room and storgae replace(6)cafeteria doors with 1.5 rated doors, replace(18)doors at stairs with C label doors, replace wet door at kitchen with fire rated door and frame and hardware. Provide closers on all classroom doors"|"1"|"S"|"1975"|"45"|"0"||"1"|"S"|"1975"|"45"|"0"||"1"|"1"|"S"|"2007"|"10"|"0"|"replace remaining obsolete secondary panel boards"|"1"|"S"|"2004"|"15"|"0"||"1"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"|"most carpet in excellent condition in office/library replace 126A, 300, 319, 326, 329"|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"|"many rooms had newer VCT"|"1"|"COMMON"|"S"|"2004"|"25"|"0"|"Terrazzo"|"1"|"INSTRUCT"|"S"|"2004"|"5"|"0"|"in 227 wood floor is not required for function. Could be removed, finish is warn"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1975"|"45"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"first floor classroom "|"S"|"1975"|"45"|"0"|"repoint masonry at stair #4 - 3 floors high two sides. Principal indicated that there is draft problems on the first floor where the floor and wall meet. We could not observe this at summer, but is a problem in winter"|"1"|"CONCRETE"|"S"|"1975"|"45"|"0"||"0"|||||"0"|"this is a three story building, roof does not have a railing"|"S"|"S"|"0"|"1"|"1975"|"5"|"0"|"replace pair of doors at exit 4 ((2)-3x7x1.75" H.M. +hardware)replace threshold at stairs #5"|"1"|"S"|"2004"|"15"|"0"|"repair exterior steps and install handrail"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1975"|"1"|"0"|"replace gaskets and hardware (dining 130-a) some windows have been replace, all remaining windows should be replaced, seals are broken."|"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"5"|"0"|"some repointing of brick at stair enclosures 1% evidence of BUR at stair tower #1 - aligatoring non invasive inspection "|"0"|||||"0"||"1"|"COPPER"|"S"|"1975"|"20"|"0"|"provide rolling ladder at backflow preventer"|"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"DD_MZ"|"1"|"BOILERWATE"||"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"|"1. add split system a/c to storage/cer 133-G"|"1"|"S"|"2008"|"5"|"0"|"1. replace cafeteria air handling system 2. replace kitchen air handling system 3. replace building relief fans 4. replace east classroom AHU 5. replace exhaust fans 6. add ventilation/exhaust to 3 rooms"|"1"|"S"|"2008"|"20"|"0"|"1. Replace building cabinet/unit heaters"|"1"|"S"|"2008"|"20"|"0"|"1. Clean cafeteria ductwork system 2. clean exhaust grilles "|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"1975"|"1975"|"0"||"1"|"S"|"2004"|"10"|"0"|"Add exit discharge lighting to emergency generator"|"1"|"S"|"2004"|"25"|"0"|"add additional transfer switch to seperate life safety and equipment"|"1"|"1"||"Restripe accessible parking spaces. Install accessible curb ramp"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"1802800"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/27/2010 3:57:41 PM| 561|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"CRIMINAL JUSTICE BLDG #18 "|"0059"|"05/17/2010"|"6985 TECHNOLOGY WAY "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"2002"|"8440"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"38"|"9,10,11,12"|"0"|"1"|"0"|"38"|"0"|"0"|||"1"|"2800"|"TECHSHOP,OTHER"|"Maintenance Shop"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"3"|"65,000"|"Cost per building to install an exterior water storage tank. "|"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"16,000"|"New slurry seal is needed/bollards need to be added. "|"1"|"CONCRETE"|"S"|"2002"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"17"|"0"|"Need 2 hour fire-rated walls and doors to go to the ceiling in the Electrical/Mechanical Rooms. "|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"0"|"S"|"2002"|"1"|"5,000"|"Install new PA System. "|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"40"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"50"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"20"|"40,000"|"Additional windows are needed. "|"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON"|"S"|"2002"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"12"|"0"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"2002"|"15"|"0"|"Replace lavatory trim wtih metering faucets (2). "|"1"|"VAV"|"1"|"OTHER"||"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"55,000"|"Move HVAC unit off roof. "|"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2002"|"5"|"1,500"|"Provide exterior egress lighting fixtures."|"0"||||"0"||"1"|"1"|"540,000"|"Reconfigure classroom space to 4 or 5 individual classroom spaces. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"1"|"0"|"FAIR"||"721,600"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/27/2010 4:07:23 PM| 562|"Mohawk CSD"|"21050204"|"FISHER ELEMENTARY SCHOOL"|"0002"|"09/02/2010"|"10 Fisher Avenue"|"MOHAWK"|" 13407"|"ANNUAL"|"10/01/2011"|"1955"|"72927"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"459"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"1"|"459"|"0"|"0"|||"24"|"21324"|"ADMIN,ART,AV,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,POOL,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"16,000"|"Provide additional storm inlet at bus loop entrance"|"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"MUNI"||"1"|"S"|"2009"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"ASPHALT"|"S"|"2009"|"15"|"0"|"Pavement in front of building in fair condition"|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"20"|"4000"|"N"|"Add railing at Lower Tolpa Field (bleachers)"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"25"|"17000"|"Parge walls in select locations"|"1"|"S"|"1996"|"35"|"10000"|"Replace deterioriating firestopping in fan room"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"15"|"136000"|"Replace ceilings in 1996 wing"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"S"|"2009"|"15"|"84000"|"Recommend replacing louvered doors in 1969 wing"|"1"|"S"|"1996"|"20"|"18000"|"Replace rubber treads"|"1"|"S"|"1996"|"20"|"0"||"1"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"1"|"S"|"2009"|"15"|"58000"|"Replace clock system/clocks"|"1"|"NF"|"1955"|"0"|"258000"|"Cost provided is to remove existing outdoor pools (2) and infill"|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"10"|"30000"|"Media Center carpet nearing end of useful life"|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"0"||"1"|"COMMON"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"20"|"0"||"1"|"MASONRY,METAL"|"S"|"2009"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"5000"|"Replace two exterior doors"|"1"|"S"|"2009"|"35"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"10"|"21000"|"Re-caulk all windows"|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"10"|"478000"|"Roof replacement will be required over 5th and 6th grade wing in next 5-7 years"|"1"|"PLASTIC"|"S"|"2009"|"10"|"0"||"1"|"COPPER"|"S"|"2009"|"15"|"44000"|"Replace water softening equipment/system"|"1"|"IRON"|"S"|"2009"|"15"|"0"||"1"|"NAT_GAS"|"U"|"1985"|"1"|"53000"|"Water heater is corroded and controls are in disrepair"|"1"|"S"|"2009"|"20"|"35000"|"Replace wall hung fixtures in 1968 wing"|"0"||"1"|"BOILERWATE"||"S"|"2009"|"25"|"0"|"One boiler was not replaced in 2009, installed in 1996 - 10 years"|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"44000"|"All data and telephone rooms are over heating"|"1"|"S"|"2009"|"25"|"0"|"Equipment pumps, tanks, controls from 1996 - 10 years"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"52000"|"Existing pneumatic controls should be replaced"|"1"|"S"|"1996"|"20"|"79000"|"Add A/V devices in corridors and classrooms"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1996"|"2"|"42000"|"Recommend replacement of emergency battery packs"|"0"||||"0"||"1"|"1"|"378000"|"Renovate remaining toilet rooms including staff toilet room"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1862000"|"U"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/27/2010 4:16:53 PM| 565|"Somers CSD"|"66210106"|"Somers High Schoo"|"0003"|"08/10/2010"|"120 Primrose Street"|"Lincolndale"|" 10540"|"ANNUAL"|"08/01/2011"|"1967"|"218030"|"2"|"9"|"1"|"DISTRICT"|"INSTRUCT"||"1038"|"9,10,11,12"|"0"|"1"|"1"|"1038"|"0"|"0"|||"24"|"19022"|"ADMIN,ART,AUDITORIUM,CAFE,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10000"|"S"|"1995"|"11"|"0"||"1"|"WELL"|"S"|"2000"|"10"|"150000"|"Two well pumps and buried exterior storage tank transfer pumps and aboveground 5000 gallon hydropneumatic tank in boiler room all functioning past expected useful life"|"1"|"SITESEPT"|"S"|"1971"|"20"|"0"||"1"|"S"|"1971"|"10"|"0"|"Propane tanks serve kitchen equipment boiler igntion and science room sinks"|"1"|"UTIL"|"BELOW"|"E"|"2008"|"20"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"|"Restore lined swales"|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"2008"|"15"|"0"|"Need to maintain and correct lower basins"|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"0"|"Patched as necessary"|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"5"|"4320"|"Repair as necessary"|"0"||||"0"||"1"|"S"|"2008"|"15"|"0"|"Y"|"Minor surface corrections"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"80000"|"Replace ceilings in 1967 and 1971 wings"|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"S"|"2008"|"20"|"96000"|"Complete replacement of second floor doors in 1967 wing"|"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"1"|"S"|"2008"|"15"|"0"|"Older panels should be replaced during next major renovation"|"1"|"S"|"2008"|"10"|"180000"|"Replace fixtures in 1967 and 1971 wings Update areas not done in 2008 during next major renovation"|"1"|"1"|"S"|"2008"|"6"|"20000"|"PA system is at capacity and should be replaced during next major renovation. Cost is to upgrade 1967 and 1971 wings"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"10"|"180000"|"Replace flooring in 1967 wings in second floor teaching spaces which are mostly VAT"|"1"|"COMMON"|"S"|"2008"|"20"|"80000"|"1967 toilet rooms on second floor need replacement"|"1"|"COMMON"|"S"|"2008"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"8000"|"Masonry control joints require replacement in 1967 and 1971 wings"|"1"|"MASONRY"|"S"|"1971"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"20"|"24500"|"Auditorium and old gym door replacement with FRP doors assuming seven doors"|"1"|"S"|"2007"|"0"|"35000"|"Gym east exit ramp stair and retaining wall reconstruction"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"0"|"460000"|"1967 and 1971 single glazed windows need replacement"|"METONMET,CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"15"|"0"||"1"|"PLASTIC"|"S"|"2008"|"15"|"0"||"1"|"COPPER"|"S"|"2008"|"15"|"0"||"1"|"IRON"|"S"|"2008"|"20"|"0"||"1"|"OIL"|"S"|"2000"|"7"|"10000"|"Heat exchanger is at end of expected useful life Cost isto replace oil fired heater"|"1"|"S"|"2008"|"15"|"30000"|"Replace fixtures in 1967 and 1971 wings"|"0"||"1"|"BOILERWATE"||"S"|"1967"|"2"|"400000"|"The two hot water boilers are original and operating at the end of their expected useful life"|"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"2000"|"6"|"30000"|"There have been some reported problems with controls of packaged roof top AC units"|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"5"|"25000"|"Existing finned tube radiators convectors and unit heaters may require repairs including covers and control valves"|"1"|"S"|"2008"|"5"|"25000"|"Cost is for miscellaneous filters coils control valves and dampers Exhaust systems are operating past their expected useful life"|"1"|"S"|"2008"|"15"|"100000"|"Older systems use pneumatic or stand alone electric controls and should be incorporated into the new DDC system installed in 2008"|"1"|"S"|"2008"|"6"|"0"|"No notification devices in older classrooms and have bell strobe devices Update remaining areas during next major renovation to match newer areas"|"1"|"S"|"2008"|"6"|"0"|"Update remaining areas during next major renovation to match newer areas"|"1"|"S"|"1971"|"1971"|"0"||"1"|"S"|"2008"|"6"|"0"|"New exit signs and new EM light fixtures should be provided in remaining areas during next major renovation"|"1"|"E"|"2008"|"25"|"0"||"1"|"1"|"8000"|"Upgrade ADA signage in 1967 and 1971 wings"|"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"|"Auditorium wing and second floor classroom area seem deficient Upgrade during next major renovation"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"|"0"|"FAIR"||"1741320"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"ekaeyer@kgdarchitects.com"|"Erik A Kaeyer AIA LEED AP"|"028179"|"I ACCEPT"|12/27/2010 4:51:20 PM| 566|"Greenwich CSD"|"64080104"|"Primary Grade Building"|"0004"|"04/08/2010"|"GRAY AVE "|"GREENWICH "|" 12834"|"ANNUAL"|"01/01/2011"|"1954"|"32,712"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"242"|"K,1,2"|"0"|"0"|"0"|"242"|"0"|"0"|||"18"|"16,000"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"12,000"|"S"|"2008"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"10"|"0"||"1"|"S"|"1980"|"20"|"0"||"0"||||"0"||"1"|"S"|"1980"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1988"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1954"|"20"|"0"||"1"|"S"|"1954"|"20"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"1"|"U"|"1999"|"10"|"48,000"|"Communication Systems are typically satisfactory (10) - the BCS has no place for Security Systems (1)."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"2007"|"15"|"0"|"Resilient Tile or Sheet Flooring are typically satisfactory (15) - the BCS has no place for replacing resilient tile flooring with a wood flooring system (3)."|"1"|"COMMON"|"S"|"1954"|"20"|"0"||"0"|||||"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1954"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1954"|"20"|"0"||"1"|"METAL"|"S"|"1975"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2007"|"1"|"64,200"|"Exterior Doors & Hardware are typically satisfactory (15) - replace 2 pairs & main entrance vestibule for security up-grades (1)."|"1"|"S"|"1954"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1980"|"3"|"353,300"|"Asbestos caulking removal NOT included in replacement cost. "|"METONMET,CONMETMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"U"|"1995"|"3"|"539,500"|"Sprayed Polyurethane Foam (SPF) over asbestos containing asphalt built-up."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2002"|"20"|"0"||"1"|"OIL,ELECTRIC"|"S"|"2010"|"15"|"0"|"1 oil & 1 electric."|"1"|"S"|"2002"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1999"|"15"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2007"|"3"|"10,800"|"Air Handling & Ventilation is typically satisfactory (15) - replace remaining original exhaust fans & gravity ventilators as part of roof replacement (3)"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"U"|"1999"|"1"|"102,000"|"Replace original building pneumatic controls with DDC controls & integrate with campus wide energy management system."|"1"|"S"|"1999"|"3"|"1,000"|"Add fire alarm strobes in toilet rooms where required by current code."|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2007"|"2007"|"0"||"1"|"U"|"1999"|"3"|"4,800"|"Exterior side of building exits require emergency lights per code."|"0"||||"0"||"0"|"1"|"0"|"Automatic door operation needed at main entrance - cost included in BCS item number 64."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"1,509,600"|"U"|"1"|"St. John Architects"|"172 Ridge Street"|"518-223-0225"|"sjarch@roadrunner.com"|"Samuel D. St. John"|"019740"|"I ACCEPT"|12/28/2010 12:17:10 AM| 573|"Fort Ann CSD"|"64050204"|"K-12"|"0001"|"07/13/2010"|"1 Catherine Street"|"Fort Ann"|" 12827-5039"|"ANNUAL"|"12/01/2011"|"1938"|"132,500"|"2"|"7"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"538"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"0"|"1"|"538"|"0"|"0"|||"53"|"43,250"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"8,000"|"0"|"0"|"E"|"2005"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2004"|"20"|"425,000"|"Provide emergency generator for backup."|"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"170,000"||"1"|"CONCRETE,ASPHALT"|"E"|"2010"|"15"|"0"||"1"|"E"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"S"|"2004"|"5"|"157,000"|"Replace door hardware for consistency; replace gym folding door with curtain."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"1"|"S"|"2004"|"5"|"285,000"|"Replace old electrical panels; provide wireless computer infrastructure"|"1"|"S"|"2004"|"5"|"315,000"|"Replace gym lighting and add switching control (not circuit breakers)."|"1"|"1"|"S"|"2004"|"5"|"30,000"|"Upgrade public address system for better coverage in the building."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"1"|"MASONRY"|"S"|"1938"|"10"|"0"||"0"|||||"0"||"E"|"E"|"1"|"1"|"2010"|"15"|"0"||"1"|"E"|"2010"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"5"|"425,000"|"Replace older windows and restore historical appearance."|"METONMET,WOODONWOOD,WOODONMET"|"SINGLEPLY,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"15"|"0"||"1"|"PLASTIC"|"S"|"2004"|"10"|"0"||"1"|"COPPER"|"S"|"2004"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"10"|"0"||"1"|"OIL"|"S"|"2004"|"15"|"0"||"1"|"S"|"2009"|"5"|"80,000"|"Reconstruct HS bathrooms for accessibility"|"0"||"1"|"BOILERWATE"||"E"|"2004"|"20"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"5"|"105,000"|"Provide ventilation in fitness center; ventilate and air condition psychologist office."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"5"|"135,000"|"Upgrade temperature control system."|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2005"|"2005"|"0"||"1"|"S"|"2004"|"5"|"55,000"|"Additional coverage needed."|"0"||||"0"||"1"|"1"|"165,000"|"Replace interior bleachers for accessibility."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"2,347,000"|"S"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, NY 12061"|"518-479-4000"|"mweber@mosaicaa.com"|"Martin Weber"|"12772"|"I ACCEPT"|12/28/2010 10:10:25 AM| 575|"Holland Patent CSD"|"41220106"|"Holland Patent Elementary"|"0005"|"08/20/2010"|"7940 Elm Street"|"Holland Patent"|" 13354"|"ANNUAL"|"10/01/2011"|"1955"|"39357"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"336"|"K,1,2,3,4,5"|"0"|"1"|"1"|"336"|"0"|"0"|||"18"|"15380"|"ADMIN,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"1000"|"S"|"1992"|"10"|"96000"|"Remove existing underground tank, replace with 250 gallon tank in boiler room"|"1"|"MUN_UTILIT"|"S"|"2002"|"1"|"5000"|"Replace leaking domestic water booster pump"|"1"|"MUN_UTILIT"|"S"|"2004"|"25"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"30"|"0"||"1"|"S"|"1980"|"10"|"0"||"0"||||"0"||"1"|"S"|"1980"|"10"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1980"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"U"|"1992"|"0"|"787000"|"Reconstruct front bus loop and parking lots"|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"1980"|"10"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"1"|"0"|"0"|"S"|"1955"|"15"|"9000"|"Crack in foundation northeast corner"|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"25"|"0"||"1"|"S"|"1994"|"9"|"0"||"1"|"S"|"S"|"2009"|"30"|"149000"|"Replace original bldg doors."|"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"5"|"17000"|"Replace corroded conduit/wiring for crawlspace lights."|"1"|"S"|"2009"|"5"|"306000"|"Replace classroom and corridor lights for energy upgrades, add OS"|"1"|"1"|"S"|"2009"|"15"|"0"|"LAN and PA and master clock replaced in Excel"|"0"||||"0"||"1"|"COMMON"|"S"|"1995"|"5"|"61000"|"Replace main office carpet - VAT underneath."|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"5"|"367000"|"replace vct over vat and vat in classrooms."|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"||"1"|"INSTRUCT"|"E"|"2009"|"15"|"0"||"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"50"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"0"|"1"|"0"||"S"|"2009"|"50"|"9000"|"North east classroom re-point brick (original building)."|"1"|"MASONRY"|"S"|"1955"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"21000"|"replace main entrance doors (2 sets)"|"1"|"U"|"2009"|"20"|"52000"|"exit ramp at north side of building not ADA compliant, stairs and railing outside loading dock"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"25"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"98000"|"Replace 1996 roof"|"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"COPPER"|"S"|"2009"|"15"|"0"||"1"|"IRON"|"S"|"2005"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"5"|"26000"|"Electric heater added for gym additions in 2008. Replace natural gas WH in Boiler room"|"1"|"S"|"2009"|"20"|"17000"|"Replace (2) mop sinks."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2009"|"15"|"0"|"New HW loop added to gym addition"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2009"|"12"|"0"||"1"|"S"|"2009"|"15"|"79000"|"Replace original LGI blower coil"|"1"|"S"|"2009"|"5"|"44000"|"Re-pipe boiler room chem. feed system into boilers, reconstruct make-up system"|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2002"|"2002"|"0"|"Ansul in kitchen"|"1"|"S"|"2009"|"10"|"0"||"0"||||"149000"|"Add generator w/ domestic water pumps to HS and BG, FA, boilers, EM ltg. loads"|"1"|"1"|"30000"|"Exterior ramp doesn't meet ADA regs of 1:12, not in satisfactory condition"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"1"|"0"|"FAIR"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"2292000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"Jim King"|"015925"|"I ACCEPT"|12/28/2010 10:15:03 AM| 576|"Somers CSD"|"66210106"|"Somers Intermediate School"|"0006"|"08/13/2010"|"240 Route 202"|"Somers"|" 10589"|"ANNUAL"|"08/01/2011"|"1971"|"90538"|"1"|"5"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"809"|"3,4,5"|"0"|"1"|"1"|"809"|"0"|"0"|||"39"|"32000"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,TEACHRSRC,OTHER"|"Stage"|"0"||||||||"0"||"1"|"WELL"|"S"|"2006"|"3"|"375000"|"Two well pumps and 15000 gallon buried exterior storage tank and transfer pumps and above ground 3000 gallon hydropneumatic tank in building cellar all functioning past expected useful life"|"1"|"SITESEPT"|"S"|"1971"|"5"|"0"|"Being replaced by utility sewer this year"|"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"15"|"0"||"1"|"S"|"1971"|"15"|"0"||"0"||||"0"||"1"|"U"|"1971"|"7"|"10000"|"Allowance to clean out gravel and debris"|"0"||||"0"||"1"|"SURFACEH2O,OTHER"|"daylight"|"1"|"S"|"1971"|"15"|"0"||"1"|"S"|"1971"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2007"|"2"|"241450"|"Repair or replace cracks broken areas and asphalt curbs"|"1"|"CONCRETE,ASPHALT,OTHER"|"U"|"1971"|"1"|"11500"|"Several sections require replacement or repair"|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"1971"|"20"|"0"|"N"||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2007"|"20"|"0"||"1"|"S"|"2007"|"20"|"31400"|"Install fire separation walls to achieve current code requirements"|"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2007"|"3"|"68855"|"Replace stained and warped ACT"|"1"|"S"|"1971"|"5"|"0"||"1"|"S"|"S"|"2007"|"5"|"34700"|"Work needed on smoke zone exiting"|"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"12"|"0"||"1"|"S"|"2000"|"5"|"26085"|"Correction of switch issues in 1971 classrooms as well as lighting issues in two classrooms"|"1"|"0"|"S"|"2000"|"5"|"125000"|"Added wings and classrooms have left a few areas deficient A new system should be considered as part of the next major renovation The control and broadcast equipment is failing"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"5"|"38500"|"Replacement of 1971 multipurpose music room carpet due to stains wear and seam separation"|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"10"|"0"||"1"|"COMMON"|"U"|"1971"|"15"|"11500"|"Replace ceramic tile with higher friction tile"|"1"|"COMMON"|"S"|"1990"|"15"|"0"|"Gym floor"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2007"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"4"|"28120"|"Cost for repointing isolated areas"|"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"2007"|"0"|"125000"|"Replace original doors in classrooms built in 1971"|"1"|"S"|"2007"|"3"|"27000"|"Repair uneven flight of stairs and railing near loading dock"|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2007"|"0"|"112000"|"1971 windows are single glazed with failing seals and need to be replaced"|"CONMETMET"|"SINGLEPLY,BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"S"|"2007"|"4"|"1696670"|"1971 built up roof and 1999 foam roof need replacement"|"1"|"PLASTIC"|"S"|"2007"|"4"|"0"|"Included in roofing cost"|"1"|"COPPER"|"S"|"1971"|"20"|"0"||"1"|"IRON"|"S"|"1971"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2000"|"7"|"0"||"1"|"S"|"1971"|"7"|"0"|"Miscellaneous fixtures have been replaced as necessary but many are original and are functioning at end of expected useful life"|"0"||"1"|"OTHER"||"S"|"1995"|"10"|"0"|"System is combination of rooftop units with electric coils and duct mounted electric reheat coils and electric strip heaters and electric cabinet heaters near entrances and exits"|"1"|"S"|"1995"|"10"|"0"|"All heating systems are electric"|"1"|"S"|"2007"|"7"|"0"||"1"|"S"|"1995"|"8"|"0"||"0"||||"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"10"|"300000"|"System should be replaced with central direct digital control DDC system when packaged AC unit systems are replaced or rehabilitated and all equipment integrated into control system"|"1"|"S"|"2000"|"7"|"200000"|"Annunciator panel is not informative enough and FACP is in electrical room which creates some confusion during alarm conditions No classroom notification devices associated with this system and should be added"|"1"|"S"|"2000"|"7"|"150000"|"Due to zoned system custodial staff has trouble finding specific detector during an alarm"|"1"|"S"|"2000"|"2000"|"0"|"Kitchen hood extiguishing system only but no wet sprinkler system in building"|"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"|"Need to add lighting at faculty lounge converted to classroom"|"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"|"0"|"1"||"FAIR"||"3612780"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"ekaeyer@kgdarchitects.com"|"Erik A Kaeyer AIA LEED AP"|"028179"|"I ACCEPT"|12/28/2010 10:17:15 AM| 577|"Holland Patent CSD"|"41220106"|"Bus Garage"|"5006"|"08/20/2010"|"Thompson Road"|"Holland Patent"|" 13354"|"ANNUAL"|"10/01/2011"|"1969"|"1440"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus maintenance"|"0"|||"0"|"1"||||||"0"|"0"|"NONE,OTHER"|"Bus maintenance"|"1"|"3"|"1000300275"|"1"|"10000"|"S"|"1995"|"5"|"66000"|"Remove underground fuel oil tank"|"1"|"MUN_UTILIT"|"S"|"1969"|"5"|"437000"|"currently pumped from HPE"|"1"|"SITESEPT"|"S"|"1969"|"5"|"70000"|"Frequent backups and regular pumping needed."|"1"|"S"|"1968"|"30"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1969"|"5"|"70000"|"Replace security lights and block heaters."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1995"|"5"|"1000000"|"pavement showing signs of wear (cracking, splitting at seams, pot holes). Condition beyond routine maintenance."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1969"|"15"|"0"||"1"|"S"|"2010"|"50"|"0"||"1"|"S"|"1969"|"10"|"0"||"1"|"S"|"1969"|"0"|"6000"|"Replace drop ceiling in office and provide drop ceiling in break room and instruction area."|"0"||||"0"||"1"|"S"|"S"|"2010"|"0"|"8000"|"Replace original building doors and hardware to ADA"|"1"|"U"|"1969"|"0"|"7000"|"Replace steel stairs"|"1"|"S"|"2005"|"15"|"0"|"bus lifts replaced"|"1"|"1"|"S"|"2009"|"10"|"0"|"RTU and receptacle branch circuits added."|"1"|"U"|"2010"|"15"|"14000"|"Replace T-12 fluorescents with T-8s"|"1"|"1"|"S"|"2002"|"10"|"0"|"Existing wireless LAN connection"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1995"|"0"|"3000"|"Replace VCT in office"|"1"|"COMMON"|"S"|"1969"|"0"|"0"|"Cost included in question about accessibility"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1969"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1969"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"15"|"3000"|"add one staff entrance door (3' hollow metal / frp) "|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1995"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2010"|"25"|"0"||"1"|"IRON"|"S"|"1968"|"25"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"5"|"14000"|"replace natural gas water heater"|"1"|"S"|"1968"|"5"|"0"|"cost included in question about Accessibility"|"1"|"CV"|"1"|"FURNACE"||"S"|"2010"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"E"|"2010"|"15"|"0"|"3-ton gas fired RTU new in 2010"|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"1"|"E"|"2010"|"15"|"0"||"1"|"S"|"2010"|"10"|"35000"|"Replace AHU, controls, duct work and add to DDC"|"1"|"S"|"2010"|"5"|"26000"|"Replace zoned panel with point addressable panel"|"1"|"S"|"2010"|"5"|"9000"|"replace devices with point addressable"|"0"||||"0"||"1"|"S"|"2010"|"10"|"0"||"0"||||"0"||"1"|"0"|"378000"|"upgrade bathrooms to make ADA."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Need enclosed bus storage - 40 bays"|"2149000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"Jim King"|"015925"|"I ACCEPT"|12/28/2010 10:33:07 AM| 578|"East Syracuse-Minoa CSD"|"42040106"|"Fremont School"|"0014"|"08/03/2010"|"RICHMOND RD "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/2010"|"1964"|"38217"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT,OTHER,OTHER_ORG"|"B&G / District Storage"|"339"|"K,1,2,3,4,5"|"0"|"1"|"1"|"339"|"0"|"0"|||"17"|"13600"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1980"|"20"|"0"||"1"|"S"|"1964"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"25"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"1964"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1964"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"|"Bus loop & parking updated w/ "Safe + Sound" project."|"1"|"CONCRETE,ASPHALT"|"E"|"2009"|"20"|"0"|"Sidewalks updated w/ "Safe + Sound" project."|"1"|"E"|"2006"|"20"|"0"||"1"|"S"|"1964"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"1"|"S"|"1964"|"50"|"0"||"1"|"S"|"1964"|"50"|"10000"|"Recommend replacing chase walls @ toilet rms @ classrooms."|"1"|"S"|"1964"|"10"|"0"|"Misc. water damaged tiles - maintenance item. "|"0"||||"0"||"1"|"U"|"U"|"1964"|"5"|"70,000"|"Recommend replacing gym doors & (21) classroom doors"|"1"|"S"|"1964"|"40"|"0"||"1"|"S"|"2003"|"30"|"0"||"1"|"1"|"U"|"1964"|"5"|"193,000"|"Add elect. panels & outlets throughout classroom wings. Replace existing switchboard"|"1"|"E"|"2009"|"25"|"0"|"Replaced w/ Energy Performance Contract."|"1"|"1"|"E"|"2009"|"15"|"0"|"Recommend updating PA. Clock system to be replaced by District; Speakers/clocks"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"|"@ Main Office / Library"|"1"|"INSTRUCT,COMMON"|"U"|"2003"|"5"|"210,000"|"Recommend abating VAT & repairing VCT various locations."|"1"|"COMMON"|"S"|"1964"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1964"|"20"|"0"|"Ongoing maintenance (sealing)."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"MASONRY,STEEL"|"1"|"0"||"1"|"0"|"0"|"0"|"0"|"damaged wall"|"S"|"2009"|"50"|"10,000"|"Recommend reconstructing damaged corner @ Kindergarten Clrm; caulk control joints"|"1"|"METAL"|"S"|"1964"|"10"|"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"2009"|"5"|"26,000"|"Recommend replacing exterior doors @ gym/cafeteria/boiler rm."|"0"|"U"|"2009"|"5"|"15,000"|"Recommend removing exterior stairs(back of gym); Add metal stair & handrail @ loading dock."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"|"Upgrades w/ Energy Performance Contract"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"0"|"1"||"U"|"1989"|"5"|"800,000"|"Recommend replacing roof system. "|"1"|"PLASTIC"|"S"|"1989"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1964"|"15"|"0"||"1"|"IRON"|"S"|"2009"|"25"|"0"|"Sanitary line @ cafeteria corrected w/ EXCEL Project."|"1"|"NAT_GAS"|"S"|"2009"|"15"|"0"|"2005 - 180 degree only serves dishwasher; 2009 serves school"|"1"|"U"|"1964"|"5"|"263,000"|"Recommend replacing all original fixtures"|"0"||"1"|"BOILERWATE"||"U"|"1964"|"5"|"600,000"|"Recommend replacing original boiler system"|"1"|"S"|"2003"|"35"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"U"|"1964"|"5"|"780,000"|"Recommend replacing original unit ventilators"|"1"|"U"|"2003"|"5"|"53,000"|"Recommend replacing misc piping w/ other HVAC upgrades"|"1"|"U"|"2003"|"5"|"21,000"|"Recommend replacing misc dampers w/ other HVAC upgrades"|"1"|"U"|"2009"|"5"|"95,000"|"Recommend upgrading controls w/ other HVAC upgrades"|"1"|"U"|"2003"|"5"|"131,000"|"Recommend replacing Simplex 4002 fire alarm system w/ point addressable system; add strobes in classrooms "|"1"|"U"|"2003"|"5"|"35,000"|"Recommend replacing devices w/ addressable system "|"0"||||"0"||"1"|"E"|"2009"|"15"|"0"|"Existing battery packs in corridors w/ LED exits."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"GOOD"||"3,312,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"3156826180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 10:42:47 AM| 579|"Chappaqua CSD"|"66100406"|"Robert Bell Middle School-Temp Bldg"|"0014"|"08/20/2010"|"50 Senter Street"|"Chappaqua"|" 10514"|"ANNUAL"|"08/01/2011"|"1975"|"1000"|"1"|"0"|"1"|"DISTRICT"|"INSTRUCT"||"20"|"5,6,7,8"|"0"|"0"|"0"|"0"|"20"|"0"|||"0"|"0"|"MUSIC"||"0"||||||||"0"||"1"|"OTHER"|"S"|"1975"|"6"|"0"||"1"|"OTHER"|"S"|"1975"|"6"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1975"|"6"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1975"|"3"|"5000"|"Holes and depressions need to be filled"|"1"|"ASPHALT"|"S"|"1997"|"6"|"0"||"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1975"|"6"|"0"||"1"|"S"|"1975"|"6"|"0"||"1"|"S"|"1975"|"6"|"8000"|"Replace wood paneling with Class C surface"|"1"|"U"|"1975"|"2"|"25000"|"Ceiling membrane peeling away from foam and needs complete resurfacing"|"0"||||"0"||"1"|"S"|"S"|"1975"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1975"|"6"|"0"||"1"|"U"|"1975"|"2"|"8000"|"Exposed lamps Lens covers are hard to obtain Replace all fixtures"|"1"|"0"|"U"|"1975"|"0"|"30000"|"This building should have a system but does not"|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"U"|"1975"|"2"|"3500"|"Allowance to replace due to cracks and bulges"|"0"|||||"0"||"0"|||||"0"||"OTHER"|"Modular"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1975"|"6"|"0"||"STEEL,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1975"|"4"|"16000"|"Siding needs to be professionally cleaned due to mildew Foundation flashing needs replacement along entire perimeter"|"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"1997"|"6"|"7000"|"Replace two doors"|"1"|"U"|"1975"|"2"|"120000"|"Replace existing ramp to be ADA compliant and maintainable during winter Needs canopy to comply with current SED code"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1975"|"6"|"150000"|"Original non insulated windows need upgrading"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1975"|"6"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"1"|"OTHER"||"S"|"1975"|"6"|"0"|"Forced hot air unit in closet"|"1"|"S"|"1975"|"6"|"0"|"Electric"|"1"|"S"|"1975"|"6"|"0"|"Electric"|"1"|"S"|"1975"|"6"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"U"|"1975"|"6"|"30000"|"Tripped alarm cuts power to building"|"1"|"S"|"1975"|"6"|"0"||"0"||||"0"||"1"|"S"|"1975"|"6"|"0"||"0"||||"0"||"0"|"1"|"120000"|"Cost allowed under exterior stair category"|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"NA"|"POOR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"FAIR"||"402500"|"U"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/28/2010 10:47:16 AM| 580|"Rockville Centre UFSD"|"28022103"|"South Side High School"|"0005"|"09/16/2010"|"140 Shepherd Street"|"Rockville Centre"|" 11570"|"ANNUAL"|"04/01/11"|"1954"|"143,219"|"2"|"12"|"0"|"DISTRICT"|"INSTRUCT"||"1144"|"9,10,11,12"|"0"|"0"|"0"|"1144"|"0"|"0"|||"62"|"49600"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,MUSIC,REMEDIAL,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"20000"|"S"|"1988"|"28"|"1,500"|"Provide signage & cage for FOST overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1954"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"5"|"0"||"1"|"S"|"1954"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2005"|"45"|"0"||"1"|"S"|"1954"|"5"|"0"||"0"||||"0"||"1"|"S"|"1954"|"5"|"14,500"|"Clean out transformer vault pit & drain, provide additional site drainage by entrance to Fireman's Island."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"600"|"Replace 20 lf. of curbing."|"1"|"CONCRETE"|"S"|"2005"|"15"|"34,000"|"Replace sidewalk at N entry (1200sf), provide sidewalk from bleachers to E walkway (120sf), replace sidewalk in front of modulars (525sf) & replace sidewalk by door to old woodshop (365sf)."|"1"|"S"|"2000"|"5"|"13,500"|"Repave basketball court (4500 sf)."|"1"|"S"|"2005"|"15"|"13000"|"N"|"Replace wood decking (160 sf), repair or replace damaged railing on main bleacher."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1954"|"10"|"0"|"Replace corridor and athletic lockers."|"1"|"S"|"S"|"1997"|"15"|"112,000"|"Upgrade hardware for ADA and replace several doors."|"1"|"S"|"1983"|"20"|"0"||"0"|"S"|"1954"|"10"|"0"||"1"|"1"|"S"|"2005"|"45"|"10,500"|"Replace missing faceplate on north wall of gym & repair lightning protection system."|"1"|"S"|"1988"|"5"|"17,000"|"Replace faulty exterior lighting photocell, reset canopy lighting time clock, repair gas shutoff pilot lights (2), replace missing stairwell ligthing lens, provide fluorescent work light on stage & add security lighting & portables."|"1"|"1"|"S"|"1986"|"5"|"107,000"|"Resecure data jack in rooms 224 & 227, replace problematic bell system, replace original clock system, provide Smart Boards in portable CR's & resecure CATC box in room 126."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"|"Replace worn carpet at several areas."|"1"|"INSTRUCT,COMMON"|"S"|"1997"|"15"|"0"||"1"|"COMMON"|"S"|"1983"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1983"|"20"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete beam slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"20"|"0"||"1"|"MASONRY"|"S"|"1954"|"20"|"25,000"|"Replace cab & provide flue cover."|"1"|"MASONRY"|"S"|"1954"|"20"|"0"||"S"|"S"|"0"|"1"|"2007"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"20"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"0"||"1"|"PLASTIC"|"U"|"1997"|"10"|"0"||"1"|"COPPER"|"S"|"1954"|"5"|"0"||"1"|"IRON"|"S"|"1954"|"5"|"26,000"|"Clear all plumbing vents at roof & provide vent caps."|"1"|"OIL"|"S"|"1995"|"5"|"40,000"|"Replace two (2) Bock oil fired heaters."|"1"|"S"|"1954"|"5"|"5,250"|"Repair drinking fountains in hall by 220, 223 & in-team locker room & provide vacuum breakers on slop sink."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"1986"|"5"|"128,500"|"Provide A/C for classrooms above kitche, A/C music room 103 & repair rattle in York packaged RTU."|"1"|"S"|"1954"|"5"|"720,500"|"Ventsadult BR,uncover UV FAI(2),provide FAI for portable CR,proper relief/exh.path for rm 216,223,231,214,wgt.rm,119,132&138,FAI for rms 218A, 218B, 230A209A208B, Att.off.,deansoffgrlcoach,artrm,UVgrillesin226,207lkrrmexhcleangymrgstrs,prov.kilnhood,"|"1"|"S"|"1954"|"5"|"0"||"1"|"S"|"1986"|"16"|"4,000"|"Replace three (3) auxiliary gym celing diffusers."|"1"|"S"|"1954"|"5"|"23,000"|"Provide separate control for library office UV, repair fan in fan room by 208, ensure all units are tied to day/night system & operating during daytime setting."|"1"|"S"|"1986"|"5"|"2,000"|"Repair FACP trouble indication."|"1"|"S"|"1986"|"5"|"31,000"|"Provide smoke detection in all basement hallway & storage areas & remove paint room smoke detector cover."|"1"|"S"|"1954"|"1954"|"0"||"1"|"S"|"1986"|"5"|"7,000"|"Provide additional exit light in library, repair/replace corridor exit sign by 227, add exit sign from basement copy area & repair/replace various non-functional exit lights."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"1"|"0"||"FULL"||"0"|"0"|"FAIR"||"1,335,850"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/28/2010 10:56:33 AM| 581|"Fort Ann CSD"|"64050204"|"Bus Garage"|"5002"|"07/13/2010"|"1 Catherine Street"|"Fort Ann"|" 12827-5039"|"ANNUAL"|"12/01/2011"|"1963"|"12800"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Garage"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"1"|"1,000"|"0"|"0"|"S"|"2004"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"10"|"0"||"1"|"ASPHALT"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"5"|"65,000"|"Replace antiquated lighting fixtures with higher efficiency fixtures."|"1"|"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2005"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2005"|"15"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"15"|"0"||"1"|"METAL"|"S"|"1988"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2005"|"15"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1963"|"5"|"120,000"||"0"|||||"0"||"1"|"COPPER"|"S"|"2004"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"15"|"0"||"1"|"OIL"|"S"|"2004"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||"1"|"FURNACE"||"S"|"1988"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2005"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"0"|"0"|"FAIR"||"185,000"|"S"|"1"|"Mosaic Associates Architects"|"73 Troy Road, East Greenbush, NY 12061"|"518-479-4000"|"mweber@mosaicaa.com"|"Martin Weber"|"12772"|"I ACCEPT"|12/28/2010 10:58:19 AM| 582|"Jefferson CSD"|"54090104"|"Main Building"|"0001"|"12/02/2010"|"1332 State Route 10"|"Jefferson"|" 12093"|"ANNUAL"|"12/01/2010"|"1937"|"54,000"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"294"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"294"|"0"|"0"|||"26"|"25,614"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"8000"|"0"|"0"|"S"|"2010"|"20"|"0"|"Fuel oil piping and alarm replaced 2010, tank 1998."|"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"|"District concern that service is leaking due to wet ground, suggest pressure test."|"1"|"SITESEPT"|"S"|"1988"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1988"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"|"Ditch between baseball fields and parking lot. District considering adding piping in lieu of ditch."|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"|"Included in field project 2000"|"1"|"SURFACEH2O"||"0"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"5"|"110000"|"Partial reconstruction 2010. Upper parking lot nearing end of useful life, reconstruct"|"1"|"CONCRETE,ASPHALT"|"E"|"2010"|"5"|"2000"|"Repair cracks and seal asphalt sidewalk K wing"|"1"|"S"|"1992"|"10"|"0"|"Pressure treated wood and steel"|"1"|"S"|"2000"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"|"Exposed foundation partially re-surfaced 2010"|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"10"|"0"|"Partial replacement 1998"|"1"|"E"|"2010"|"20"|"0"|"Partial replacement 2010, remainder 1988 vintage"|"1"|"S"|"E"|"2010"|"20"|"0"|"Partial replacement 2010 for accessibility"|"1"|"S"|"1988"|"10"|"0"|"Rubber tread / riser replacement anticipated, some risers to be re-adhered 2011"|"1"|"S"|"1988"|"20"|"0"||"1"|"1"|"S"|"2010"|"5"|"4000"|"Panel in boiler room pre-dates 1988 renovation, near end of useful life. Remaining replaced 1988 or new 2010."|"1"|"S"|"2010"|"10"|"0"|"Partial fixture replacement 1995"|"1"|"1"|"E"|"2010"|"20"|"0"|"Phone and PA replaced 2010"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"0"|"Carpet in (2) classrooms to be replaced by District 2011."|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"0"|"VAT tile in classrooms/corridor 1952 vintage"|"1"|"COMMON"|"S"|"2010"|"10"|"0"|"Ceramic tile 2nd floor public toilets installed 1979"|"1"|"COMMON"|"E"|"2010"|"20"|"0"|"Stage floor pre-1952"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"1"|"0"||"S"|"2010"|"20"|"0"|"Thru wall flashing at 1998 gym addition to be investigated, appears to be leaking"|"1"|"MASONRY"|"S"|"2010"|"20"|"0"||"1"|"MASONRY"|"S"|"1937"|"5"|"7500"|"Sealant at coping stone joints required"|"S"|"S"|"0"|"1"|"2010"|"15"|"0"||"1"|"S"|"1988"|"5"|"15000"|"K-wingstair surface deterioration"|"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"E"|"Y"|"2010"|"20"|"0"|"All windows replaced 2010"|"METONMET,WOODONWOOD,CONMETMET"|"SINGLEPLY,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"10"|"0"|"Slate roof/gutter replacement within 10 years"|"1"|"GLASS"|"E"|"2010"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1988"|"20"|"0"|"Partial replacement 1988"|"1"|"IRON"|"S"|"1988"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"10"|"0"|"Replace fixtures/flush valves in original building public toilet rooms, second floor, 1988 vintage"|"0"||"1"|"BOILERWATE"||"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"5"|"210000"|"Unit ventilators installed 1988 at end useful life (25 total), replacement can be phased, 8,500 each"|"1"|"S"|"1988"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"10"|"25000"|"DDC installed 2010, remaining equipment on pneumatic system to be added to DDC system when replaced. 25 at 1,000 each"|"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"2010"|"0"|"Kitchen hood installed 2010. building un-sprinklered."|"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"1"|"1"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"0"|"1"|"1"|"SPOT"|"1"|"0"||||"1"|"0"||"FULL"||"1"||"GOOD"||"373500"|"S"|"0"|"CSArch"|"40 Beaver St, Albany, NY"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/28/2010 11:03:41 AM| 587|"Oneida City SD"|"25140001"|"Oneida Castle Elementary"|"0009"|"08/27/2010"|"FIRST ST "|"ONEIDA CASTLE "|" 13421"|"ANNUAL"|"11/01/2010"|"1957"|"29558"|"1"|"1"|"1"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"148"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"1"|"148"|"0"|"0"|||"9"|"7000"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"15"|"0"||"1"|"SITESEPT"|"S"|"1994"|"15"|"0"|"Septic filed located in Town park property. Portion municipal sewer"|"1"|"S"|"1957"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1957"|"10"|"0"||"1"|"S"|"2004"|"25"|"0"||"0"||||"0"||"1"|"S"|"2004"|"25"|"0"||"0"||||"0"||"0"|"MUNI,ONSITE"||"1"||||"0"|"Drainage infrastructure ties into municipal system."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"20"|"11000"|"Recommend sealing cracks and re-striping parking lines"|"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"20"|"0"|"Sidewalks replaced under 2004 Capital Project."|"1"|"E"|"2009"|"10"|"0"|"play area in town park"|"0"||||"0"||"School uses adjacent Town park. No formal play fields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"10"|"0"||"1"|"S"|"1957"|"15"|"0"|"Metal stair to Boiler Room"|"0"||||"0"||"1"|"1"|"S"|"1995"|"25"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 - New district wide VoIP telephone (8yr lifespan); PA (15yr lifespan)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2004"|"5"|"7000"|"Recommend replacing carpet at Teacher Lounge"|"1"|"INSTRUCT,COMMON"|"U"|"2004"|"5"|"80000"|"Recommend replacing gym floor & abating VAT @ Main Office/Nurse"|"1"|"COMMON"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1996"|"15"|"0"|"minor cracks at masonry"|"1"|"MASONRY"|"S"|"1996"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1994"|"15"|"0"|"New security system installed w/ EXCEL funds."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"15"|"0"|"Storefront system @ main entry is original - good condition"|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Replaced roof ('57 & '72 wings) w/ EXCEL funds."|"0"|||||"0"||"1"|"COPPER"|"S"|"1987"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"15"|"0"||"1"|"NAT_GAS"|"U"|"2000"|"5"|"9000"|"Recommend replacing water heater"|"1"|"S"|"2010"|"25"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2010"|"25"|"0"|"Multi-zone RTU replaced in 2010"|"1"|"E"|"2010"|"30"|"0"|"Multi-zone RTU replaced in 2010"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2010"|"25"|"0"|"Multi-zone RTU replaced in 2010"|"1"|"S"|"2002"|"10"|"0"||"1"|"U"|"1995"|"5"|"67000"|"Recommend replacement"|"1"|"U"|"1995"|"5"|"67000"|"Recommend replacement"|"1"|"S"|"1994"|"1994"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"|"District is considering building consolidation, which may affect this building"|"241000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 11:30:42 AM| 590|"Oneida City SD"|"25140001"|"Oneida High School"|"0001"|"08/17/2010"|"560 SENECA ST "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1958"|"131300"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"764"|"9,10,11,12"|"0"|"1"|"1"|"764"|"0"|"0"|||"89"|"68500"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||"2009"||"0"|"Removed 10k gal underground tank w/ EXCEL funds."|"1"|"MUN_UTILIT"|"S"|"1958"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1958"|"25"|"0"||"1"|"S"|"1958"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"20"|"0"||"1"|"S"|"2009"|"30"|"0"|"Drainage infrastructure replaced in 2003/2009"|"1"|"S"|"2009"|"25"|"0"|"Drainage channel located along north property line (maintained by City)"|"1"|"S"|"2009"|"20"|"0"|"Drainage infrastructure replaced in 2003/2009"|"1"|"S"|"1990"|"20"|"0"|"(2) 48" concrete culvert to Higinbotham Brook (portion of culvert under gym)"|"1"|"MUNI,SURFACEH2O,ONSITE"||"1"|"U"|"1990"|"5"|"9000"|"Periodic maintenance required (rip-rap stone for stabilization)"|"1"|"S"|"2009"|"30"|"0"|"Drywells/infiltration trenches used for stormwater management."|"0"||||"0"||"0"||||"0"||"1"|"S"|"2006"|"20"|"0"|"CDS pollutant separator (Vortex Unit)"|"1"|"ASPHALT,GRAVEL"|"E"|"2010"|"25"|"0"|"All parking/driveway pavement replaced under 2006/2009 projects"|"1"|"CONCRETE,ASPHALT"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"U"|"2009"|"5"|"131000"|"N"|"Recommend natural grass stadium be top-dressed & over seeded"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"50"|"0"||"0"|"S"|"1997"|"50"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"U"|"2004"|"5"|"20000"|"Recommend replacing classroom hardware (non-ADA compliant) - Qty+/-35"|"1"|"S"|"1958"|"10"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"1"|"S"|"2009"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 - district wide VoIP telephone & HS P/A systems expansion for addition & reno only"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1995"|"5"|"78000"|"Recommend replacing @ Media Center, Teacher Lounge, & Guidance area"|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"0"||"1"|"COMMON"|"S"|"2009"|"40"|"0"||"1"|"INSTRUCT"|"S"|"1997"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"50"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2009"|"35"|"5000"|"Recommend repairing cracks masonry & caulking joints @ Main, G & V entries"|"1"|"MASONRY"|"S"|"1958"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"25"|"0"||"1"|"S"|"1958"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2009"|"5"|"300000"|"Recommend replacing remaining single pane windows (i.e. locker room & classrooms)"|"METONMET,CONMETMET,OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"GALVANIZED"|"S"|"1958"|"25"|"0"||"1"|"IRON,COPPER,PVC,OTHER"|"S"|"1997"|"25"|"0"|"Other = Acid waste piping"|"1"|"NAT_GAS"|"S"|"1999"|"5"|"44000"|"Recommend replacing water heaters below kitchen"|"1"|"S"|"2010"|"40"|"0"||"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"|"Window units & PTAC units in offices; ductless in computer closets"|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2000"|"8"|"0"|"Expansion & upgrades for additions & renovations only"|"1"|"S"|"2000"|"8"|"0"|"Expansion & upgrades for additions & renovations only"|"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2009"|"10"|"0"|"2009 - Additions, renovations, and replaced deficient units."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"587000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 11:53:21 AM| 592|"Chappaqua CSD"|"66100406"|"Central Admin Building"|"1007"|"10/29/2010"|"66 Roaring Brook Road"|"Chappaqua"|" 10514"|"ANNUAL"|"05/01/2011"|"1990"|"14400"|"3"|"1"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"7"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"7"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"20"|"20000"|"Replace CT metering cabinet which is rusting due to water penetration thru below grade incoming elec service conduits which should be water sealed"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"4"|"60000"|"Allowance to repave within 5 years to prevent minor cracking from spreading"|"1"|"OTHER"|"S"|"1990"|"4"|"15000"|"Reset sunken pavers"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"6"|"0"||"1"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"|"S"|"1990"|"10"|"10000"|"Allowance for replacement of ACT as needed over next 5 years throughout the building"|"0"||||"0"||"1"|"S"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"|"Replacement of light fixtures is scheduled as part of an already funded energy performance contract"|"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1990"|"2"|"30000"|"Replace worn and stained carpet throughout"|"1"|"COMMON"|"S"|"1990"|"15"|"0"||"1"|"COMMON"|"S"|"1990"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"10"|"0"||"1"|"MASONRY,METAL"|"S"|"1990"|"7"|"0"|"Chimney serves boiler and domestic water heater"|"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"7"|"0"||"1"|"S"|"1990"|"2"|"38000"|"Add topsoil to cover the roots Add handrails at exterior exit stair from basement"|"0"|||||"0"||"1"|"WOODCLAD"|"S"|"NA"|"1990"|"10"|"5000"|"Repair water damage at windows in conference room in basement"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1990"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2010"|"15"|"0"|"New AO Smith ProMax GLV 50 200 installed"|"1"|"S"|"1990"|"7"|"0"|"ADA compliant fixtures in first floor bathrooms"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1990"|"7"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"0"|"0"|"Two air cooled condensers on south side are scheduled to be replaced under already funded energy performance contract"|"1"|"S"|"1990"|"0"|"40000"|"Allowance to provide mechanical ventilation to three occupied rooms in basement Two viertical air handlers are scheduled to be replaced during upcoming energy performance contract"|"1"|"S"|"1990"|"7"|"0"||"1"|"S"|"1990"|"7"|"0"||"1"|"S"|"1990"|"7"|"0"||"1"|"S"|"1990"|"7"|"40000"|"Strobe coverage is not ADA compliant and should be brought up to current code"|"1"|"S"|"1990"|"7"|"0"|"FA system has elevator smoke recall and duct smoke detectors only Portable fire extinguishers in good condition"|"0"||||"0"||"1"|"S"|"1990"|"7"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"NA"|"GOOD"|"No classrooms"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"No ventilation in basement No operable windows and no ducted ventilation See item 89"|"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"258038"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/28/2010 11:55:45 AM| 593|"Rockville Centre UFSD"|"28022103"|"South Side MIddle School"|"0002"|"09/23/2010"|"67 Hillside Avenue"|"Rockville Centre"|" 11570"|"ANNUAL"|"01/01/2011"|"1922"|"145,600"|"3"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"844"|"6,7,8"|"0"|"1"|"0"|"844"|"0"|"0"|||"52"|"41,600"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,MUSIC,REMEDIAL,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1988"|"28"|"650"|"Provide signage at overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1922"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1922"|"5"|"0"||"1"|"S"|"1922"|"28"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2005"|"45"|"0"||"1"|"S"|"1922"|"5"|"117,500"|"Provide add'l drainage in both ctyd, prov. drainage in front of bleacher area & by SW gate to field, repair roof drainage system by long jump area at E wall (2) & at front wall (2), add drainage at S. side of football field."|"0"||||"0"||"1"|"S"|"1922"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"19,000"|"Repave rear asphalt area by bleachers (5,500 sf), repave E. side driveway (12,000 sf)."|"1"|"CONCRETE"|"S"|"2005"|"15"|"19,000"|"Replace flagstone walk in coury yard from auditorium exit to hall (90 sf), replace court yard decking with plastic wood, replace curb/sidewalk at E. side of building (375 sf)."|"0"||||"0"||"1"|"S"|"2005"|"15"|"28,700"|"N"|"Replace seating on baseball bleachers (5 rows @ 20lf), repalce nets & hardware on tennis courts, repair tennis court fencing, replace steel flagpole with aluminum, repair fence at NW corner or building."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1993"|"20"|"0"||"1"|"S"|"1966"|"20"|"0"||"1"|"S"|"1966"|"20"|"0"||"1"|"S"|"1993"|"15"|"0"||"1"|"S"|"1966"|"10"|"0"|"Consider replacement in the future!"|"1"|"S"|"S"|"1993"|"10"|"0"||"1"|"S"|"1993"|"15"|"0"||"1"|"S"|"1993"|"15"|"0"||"1"|"1"|"S"|"1986"|"26"|"22,000"|"Provide additional electrical circuits to 3 area, add outlets in hallways."|"1"|"S"|"2005"|"15"|"6,500"|"Reinstall damaged gym lighting guard, relocate stage work lighting."|"1"|"1"|"S"|"1986"|"5"|"247,000"|"Replace 4 battery clocks w/wireless, provide snd syst for 2 gyms, add ext. PA spkrs by fields, rerout sound wires in audt. provide sound syst for cafe, add 2nd electric door strike & Smart Boards to remaning CR's."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1993"|"5"|"115,000"|"Replace deteriorated carpet in several areas."|"1"|"INSTRUCT,COMMON"|"S"|"1993"|"15"|"0"||"1"|"COMMON"|"S"|"1993"|"15"|"0"||"1"|"COMMON"|"S"|"1988"|"15"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1993"|"20"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"20"|"0"||"1"|"MASONRY"|"S"|"1966"|"20"|"0"|"Provide new gap and rain diverter."|"1"|"MASONRY"|"S"|"1993"|"15"|"0"||"S"|"S"|"0"|"1"|"2002"|"10"|"40,000"|"Replace several pairs of exterior doors."|"1"|"S"|"1993"|"15"|"0"||"1"|"S"|"1"|"1998"|"10"|"0"|"Close risers & paint."|"1"|"ALUMINUM"|"S"|"Y"|"2006"|"20"|"0"||"METONMET,WOODONWOOD,WOODONMET"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"10"|"464,000"|"Replace areas not yet replaced in recent program, above 218-222 and above stage. Consider boys gym."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1986"|"26"|"0"||"1"|"IRON,GALVANIZED"|"S"|"1986"|"26"|"0"||"1"|"OIL"|"S"|"1986"|"5"|"22,500"|"Upgrade hot water capacity, repair leak on 1 DHWH."|"1"|"S"|"1922"|"5"|"17,750"|"Provide eyewash in custodial areas, provide vacuum breker on slop sinks (2), replace hall drinking fountain front push bar, replace boys licker room bathroom fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1986"|"16"|"0"||"1"|"S"|"1986"|"16"|"0"||"1"|"S"|"1986"|"6"|"15,500"|"Reinstall pigeon wire on McQuay RTU, provide A/C for wire closet."|"1"|"S"|"1922"|"5"|"156,750"|"Repair noisy rooftop exh fan, repl 3 old fans, add FAI to ASC rm, forn. lang, 401, 216, psych offic, student intervention, prov. bird scrn on attic GR dampers, uncover gym RA grille (padded over), repl missing audit AHU access door."|"1"|"S"|"1986"|"26"|"2,000"|"Repair leak by boiler #1."|"1"|"S"|"1986"|"26"|"0"||"1"|"S"|"1986"|"5"|"0"|"Tie all units to day/night system to ensure daytime operation (many units not running), refurbish ATC system, replace damaged gym thermostat."|"1"|"S"|"2003"|"13"|"33,000"|"Verify fan shutdown and add as required."|"1"|"S"|"2003"|"13"|"7,500"|"Add smoke detection to band & music room."|"1"|"S"|"1986"|"1986"|"0"||"0"|"S"|"1986"|"5"|"1,000"|"Repair damaged emergency light in auxiliary gym."|"0"||||"0"||"1"|"1"|"162,000"|"Provide lifts to music spaces. Replace knobs with levers."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"0"|"0"|"FAIR"||"1,497,350"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/28/2010 12:07:03 PM| 595|"Perry CSD"|"67120106"|"High School"|"0001"|"05/08/2010"|"33 Watkins Ave"|"Perry"|" 14530"|"ANNUAL"|"06/11/2011"|"1956"|"121,900"|"2"|"1"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"303"|"9,10,11,12"|"0"|"1"|"1"|"303"|"0"|"0"|||"53"|"110,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"15"|"35,000"|"Expand parking lot at Maintenance Entrance."|"1"|"CONCRETE"|"S"|"2002"|"15"|"12,000"|"New sidewalks to Watkins Avenue."|"0"||||"0"||"1"|"S"|"2008"|"10"|"140,000"|"Y"|"Relocate Baseball Field and reconstruct retaining wall."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"75,000"|"Install ceramic tile on corridor wall and renovate lobby space."|"1"|"S"|"2002"|"20"|"125,000"|"Insulate deck above ceilings at Second Floor wing. Install new Cafeteria ceiling."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"S"|"2002"|"20"|"150,000"|"Replace classroom doors and hardware."|"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"1"|"S"|"2003"|"10"|"130,000"|"Install additional receptacles for classrooms and replace panel boards."|"1"|"S"|"2003"|"15"|"124,000"|"Install new Cafeteria lighting, Gymnasium lighting, occupancy sensors, and exterior lights."|"1"|"1"|"S"|"2003"|"10"|"310,000"|"New Data Distribution system, security system upgrades, Auditorium sound upgrades, and A/V system."|"1"|"S"|"2001"|"30"|"340,000"|"Replace Pool Pak unit and pump."|"1"|"COMMON"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1995"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"MASONRY"|"0"|"1"|"NO"|"1"|"1"|"0"|"1"|"0"||"S"|"2002"|"5"|"40,000"|"Reconstruct lintels above windows at 1955 wing."|"1"|"MASONRY"|"S"|"1990"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"10"|"35,000"|"Replace front entrance doors."|"1"|"S"|"2002"|"15"|"30,000"|"Replace exit steps and retaining wall at end of corridor at Classroom 164."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"15"|"390,000"|"Replace roof over Guidance area and Auditorium."|"1"|"PLASTIC"|"S"|"2002"|"15"|"0"||"1"|"COPPER"|"S"|"2003"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"86,000"|"New fixtures at Faculty toilets."|"1"|"CV,VAV,DD_MZ"|"0"|"BOILERWATE"||"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"631,000"|"REplace AHU to Kitchen; replace UC control panels; upgrade ventilation to Second Floor classrooms; upgrade District Office AHUs; revise ductwork at Gymnasium; replace UFDs on HVAC motors."|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"30,000"|"Revise Gymnasium ductwork."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"50,000"|"Add additional equipment to system."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"FIREALARM,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"$2,733,000"|"S"|"1"|"Habiterra Architecture "|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/28/2010 12:32:17 PM| 597|"Commack USFD"|"58041003"|"SAWMILL INTERMEDIATE SCHOOL"|"0036"|"04/05/2010"|"NEW HIGHWAY "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1972"|"138663"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"825"|"6,7,8"|"0"|"1"|"0"|"35"|"0"|"0"|||"35"|"40085"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM"||"1"|"0"|"0"|"1"|"15000"|"S"|"2004"|"33"|"0"||"1"|"MUN_UTILIT"|"S"|"1972"|"11"|"0"||"1"|"SITESEPT"|"S"|"1972"|"15"|"0"||"1"|"S"|"2004"|"43"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1972"|"13"|"0"||"1"|"S"|"1972"|"15"|"0"||"0"||||"0"||"1"|"S"|"1972"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1972"|"5"|"0"||"1"|"CONCRETE"|"S"|"1972"|"5"|"0"||"1"|"U"|"2003"|"25"|"5000"|"Replace one original swing set which was not replaced in 2003."|"1"|"S"|"1972"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"25"|"0"||"1"|"S"|"1972"|"25"|"0"||"1"|"S"|"1972"|"25"|"0"||"1"|"S"|"2007"|"25"|"0"|"Only the corridor ceilings were replaced."|"1"|"S"|"1972"|"3"|"0"||"1"|"S"|"S"|"1972"|"5"|"0"||"1"|"S"|"1972"|"15"|"0"||"1"|"S"|"1972"|"13"|"0"||"1"|"1"|"S"|"1972"|"13"|"0"||"1"|"S"|"2007"|"5"|"0"|"Fixtures in corridors were replaced with the ceiligs."|"1"|"1"|"S"|"2007"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1972"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1972"|"5"|"0"||"1"|"COMMON"|"S"|"1972"|"5"|"0"||"1"|"COMMON"|"S"|"1972"|"5"|"0"||"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"1"|"MASONRY,METAL"|"S"|"2004"|"23"|"0"|"A metal chimney was installed."|"1"|"MASONRY"|"S"|"1972"|"20"|"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"0"|"Some doors were replaced with hollow metal doors."|"1"|"S"|"1972"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"10"|"0"||"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"|"Roofing was replaced this past Summer."|"1"|"OTHER"|"S"|"1972"|"15"|"0"||"1"|"COPPER"|"U"|"1972"|"1"|"10000"|"Provide building shut-off valves."|"1"|"IRON"|"S"|"2010"|"11"|"0"|"Leaks in Basement were repaired in the Summer of 2010."|"1"|"OIL,NAT_GAS"|"S"|"2004"|"3"|"0"||"1"|"S"|"1972"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2010"|"10"|"0"|"Supplementary units were replaced in the Summer."|"1"|"S"|"2004"|"33"|"0"||"1"|"S"|"1992"|"5"|"0"||"1"|"S"|"2010"|"15"|"0"|"4 rooftop units were replaced."|"1"|"S"|"2010"|"15"|"0"|"Piping replaced with rooftop units."|"1"|"S"|"1972"|"11"|"0"|"Ductwork insulation was replaced with rooftop units."|"1"|"S"|"2004"|"18"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2009"|"2009"|"0"|"Kitchen Ansul system was upgraded."|"1"|"S"|"2010"|"5"|"0"|"Some exit lights were replaced."|"1"|"S"|"1972"|"13"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|"WARMING"|"0"|"1"||"GOOD"||"$ 30,000"|"U"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/28/2010 12:44:33 PM| 598|"Oneida City SD"|"25140001"|"Administration Building"|"1019"|"09/02/2010"|"565 SAYLES STREET "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1988"|"4636"|"2"|"0"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"1"||||||"0"|"0"|"ADMIN,OTHER"|"Conference room"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1988"|"15"|"0"||"1"|"E"|"2009"|"30"|"0"|"Drainage improvement w/ EXCEL funds/2009 Capital Project"|"1"|"E"|"2009"|"20"|"0"|"Grass dry swales function as infiltration areas "|"1"|"E"|"2009"|"25"|"0"||"0"||||"0"||"0"|"SURFACEH2O,ONSITE"||"1"||||"0"|"Ties into HS drainage system, which discharges to Higinbotham Brook"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"25"|"0"|"Reconstructed parking & roadways w/ EXCEL funds."|"1"|"CONCRETE"|"E"|"2009"|"25"|"0"|"New sidewalks/curbs w/ EXCEL funds."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1988"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"New district-wide VOIP telephone system "|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"1988"|"10"|"0"||"1"|"COMMON"|"S"|"1988"|"15"|"0"|"Ceramic tile @ lobby"|"0"|||||"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"MASONRY,WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"20"|"0"||"1"|"MASONRY"|"S"|"1988"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"NA"|"1988"|"15"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"U"|"1988"|"5"|"15000"|"Recommend replacing roof system."|"0"|||||"0"||"1"|"COPPER"|"S"|"1988"|"15"|"0"||"1"|"IRON"|"S"|"1988"|"15"|"0"||"1"|"NAT_GAS"|"U"|"1988"|"5"|"9000"|"Recommend replacing water heater"|"1"|"S"|"1988"|"15"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"U"|"1988"|"5"|"10000"|"Recommend upgrades"|"1"|"U"|"1988"|"5"|"10000"|"Recommend upgrades"|"0"||||"0"||"1"|"U"|"1988"|"5"|"9000"|"Recommend upgrades"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"53000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 1:07:30 PM| 599|"Oneida City SD"|"25140001"|"Durhamville Elementary"|"0008"|"08/27/2010"|"MAIN ST "|"DURHAMVILLE "|" 13054"|"ANNUAL"|"11/01/2010"|"1958"|"41810"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"311"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"311"|"0"|"0"|||"24"|"18500"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"10000"|"S"|"2009"|"10"|"0"|"Fuel tank monitoring system w/ EXCEL funds."|"1"|"MUN_UTILIT"|"S"|"1991"|"25"|"0"||"1"|"SITESEPT"|"U"|"1991"|"5"|"525000"|"Recommend replacing site sanitary due to age/code reqmt's"|"1"|"S"|"2003"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1991"|"20"|"0"||"1"|"S"|"2010"|"30"|"0"|"Drainage improvements completed at bus loop."|"1"|"S"|"2005"|"20"|"0"|"Property is located in low area w/ high ground water table."|"1"|"S"|"2005"|"25"|"0"||"1"|"E"|"2010"|"30"|"0"|"Driveway culvert replaced in 2010."|"1"|"SURFACEH2O,ONSITE,OTHER"|"Stream"|"1"|"S"|"2005"|"10"|"0"|"Discharge to Brandy Brook"|"1"|"S"|"2005"|"25"|"0"|"Drywells/infiltration trenches used for stormwater management"|"0"||||"0"||"0"||||"0"||"1"|"S"|"2005"|"25"|"0"|"CDS pollutant separator (Vortex Unit)"|"1"|"ASPHALT"|"E"|"2010"|"30"|"5000"|"Recommend re-striping east parking lot."|"1"|"CONCRETE,ASPHALT"|"E"|"2010"|"25"|"0"|"New sidewalks w/ EXCEL funds."|"1"|"E"|"2010"|"15"|"0"|"Replaced equipment & material under playground equipment w/ EXCEL funds."|"1"|"U"|"2004"|"5"|"88000"|"N"|"Seasonal wetness requiring drainage improvements @ multipurpose field"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"15"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"1990"|"10"|"0"|"Some ceilings are part of deck."|"0"||||"0"||"1"|"U"|"S"|"2004"|"5"|"50000"|"Recommend replacing approx (16) original doors"|"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2009"|"20"|"0"|"2009 - Branch wiring @ '57 replaced & new panel boards "|"1"|"S"|"2003"|"20"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"New district wide VOIP (8 yr lifespan & P/A system (15 yr lifespan)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"2004"|"25"|"0"|"Ceramic tile @ corridors"|"1"|"INSTRUCT"|"S"|"2004"|"25"|"0"|"Ongoing maintenance (sealing)"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"25"|"0"|"Brick re-pointing completed w/ EXCEL funds."|"1"|"MASONRY"|"S"|"1958"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"25"|"0"|"New security system installed w/ EXCEL funds."|"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1990"|"10"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"20"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"1991"|"25"|"0"||"1"|"OIL"|"U"|"1991"|"5"|"18000"|"Recommend replacing water heater"|"1"|"S"|"2003"|"15"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"E"|"2010"|"30"|"0"||"1"|"E"|"2010"|"25"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"E"|"2010"|"25"|"0"||"1"|"E"|"2010"|"25"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2009"|"15"|"0"|"2009 - New fire alarm system installed."|"1"|"E"|"2009"|"15"|"0"|"2009 - New smoke detection system installed."|"1"|"S"|"1991"|"1991"|"0"||"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"|"District is considering building consolidation, which may affect this building"|"686000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 1:25:56 PM| 600|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #12-TRADES "|"0055"|"05/17/2010"|"1126 BALD HILL ROAD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1988"|"4757"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"23"|"9,10,11,12"|"0"|"0"|"0"|"23"|"0"|"0"|||"1"|"3800"|"TECHSHOP,OTHER"|"Maintenance Shop"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"2"|"64,000"|"Cost per building to install an exterior water storage tank (existing water system is adequate)."|"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1988"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"12"|"0"|"New slurry seal is needed."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1988"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1998"|"25"|"0"||"1"|"S"|"1988"|"5"|"0"||"1"|"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1988"|"20"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"STEEL,WOOD,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1988"|"10"|"0"|"Soffitt and fascia are rotting and are missing the metal siding."|"0"|||||"0"||"0"|||||"0"||"U"|"U"|"1"|"1"|"1998"|"3"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1988"|"15"|"0"||"1"|"IRON"|"S"|"1988"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1988"|"6"|"0"||"1"|"S"|"1988"|"15"|"0"||"0"||"1"|"OTHER"||"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"1"|"S"|"1988"|"1"|"5,000"|"Needs ventilation."|"0"||||"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"1988"|"5"|"2,000"|"Provide exterior egress lighting fixtures. "|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"POOR"|"Need to add additional ventilation. "|"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"|||"0"|"1"|"0"|"FAIR"||"10,000"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/28/2010 1:35:32 PM| 604|"Canastota CSD"|"25090106"|"Junior-Senior High School"|"0005"|"9/9/2010"|"220 N PETERBORO "|"CANASTOTA "|" 13032"|"ANNUAL"|"11/1/10"|"1927"|"16409"|"3"|"1"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"|"Community Organizations"|"283"|"K,1"|"0"|"0"|"0"|"283"|"0"|"0"|||"17"|"13129"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1976"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1927"|"15"|"0"||"1"|"S"|"1927"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1993"|"15"|"0"||"1"|"S"|"1996"|"25"|"0"|"One storm connection extends to Roberts St and one to Peterboro St"|"1"|"S"|"2006"|"25"|"0"|"A storm drainage swale is located on the east side of the property"|"1"|"S"|"1996"|"25"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1964"|"25"|"0"||"1"|"E"|"1996"|"25"|"0"|"A drywell was installed by the district in the playfield area"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1998"|"5"|"45000"|"Recommend crack filling, seal coating, and restriping pavement 27000 Recommend replacement of deteriorated portions of curbing along First St 18000"|"1"|"CONCRETE"|"U"|"1976"|"5"|"30000"|"Recommend replacement of walkway and curbing along Peterboro St"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"U"|"1996"|"5"|"10000"|"Water infiltration"|"1"|"U"|"1927"|"25"|"15000"|"Recommend repairing deteriorated plaster at interior classrooms"|"1"|"S"|"2000"|"25"|"0"|"Recommend repairing deteriorated plaster See question 66 for cost"|"1"|"S"|"2009"|"5"|"4000"|"Replace ceiling tiles at second floor stairs"|"1"|"U"|"1998"|"5"|"10000"|"Replace gym lockers"|"1"|"S"|"U"|"2000"|"5"|"82000"|"Recommend updating hardware to be ADA compliant"|"1"|"U"|"1927"|"5"|"15000"|"Recommend replacing damaged terrazzo stair treads"|"1"|"S"|"1993"|"20"|"0"||"1"|"1"|"S"|"1993"|"15"|"0"|"Existing Cutler Hammer 800A MCB/MDP"|"1"|"S"|"2002"|"15"|"0"||"1"|"1"|"U"|"2010"|"5"|"123000"|"Existing Dukane PA ATS4 Master Clock upgrade LAN hardware add drops for 1Gb replace phone system"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1988"|"5"|"225000"|"Recommend replacing carpet"|"1"|"INSTRUCT,COMMON"|"U"|"1988"|"5"|"14000"|"Recommend replacing VCT at vestibules"|"1"|"INSTRUCT,COMMON"|"U"|"2009"|"5"|"16000"|"Recommend patching and repainting concrete in gym corridor"|"1"|"INSTRUCT"|"S"|"2009"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"30"|"0"||"CONCRETE,MASONRY,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"U"|"1993"|"5"|"13000"|"Recommend brick repointing clean stone and paint CMU"|"1"|"MASONRY"|"U"|"1996"|"5"|"1000"|"Recommend brick repointing and cleaning"|"0"|"MASONRY"|"S"|"2004"|"15"|"0"||"S"|"S"|"0"|"0"|"2009"|"14"|"0"||"1"|"U"|"1927"|"5"|"27000"|"Replace heavily deteriorated entry and steps into the north and south sides of the building"|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2000"|"5"|"575000"|"Replace all single pane windows"|"WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2000"|"20"|"0"||"1"|"IRON"|"S"|"2000"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2006"|"10"|"0"|"Domestic water heater replaced in 2006 Dishwasher water heater replaced in 1992"|"1"|"U"|"2000"|"5"|"42000"|"Recommend replacing damaged nonfunctioning fixtures"|"0"||"1"|"BOILERWATE"||"U"|"1988"|"5"|"26000"|"2 HBSmith cast iron boilers 2500 MBH input 1975 MBH output each Single relief for each boiler 2nd relief is reqd by code"|"1"|"S"|"1988"|"10"|"0"||"1"|"U"|"2000"|"5"|"158000"|"Recommend replacing packaged rooftop HVAC equipment near end of useful life"|"1"|"U"|"2000"|"5"|"26000"|"Recommend replacing Nurses Office fan coil unit near end of useful life"|"1"|"U"|"2000"|"5"|"100000"|"Replace some unit ventilators"|"1"|"U"|"2000"|"5"|"44000"|"Ductwork cleaning is recommended as part of rooftop replacement"|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"|"Mirtone 8000 Series room for expansion"|"1"|"S"|"2000"|"10"|"0"||"0"|"U"|"2000"|"2000"|"12000"|"Add ansul system over gas range in kitchen "|"1"|"U"|"2000"|"5"|"5000"|"Replace exit signs and battery packs "|"0"||||"0"||"1"|"1"|"2000"|"Install metal signs for handicapped parking spaces 1600 Only accessible route is through back of building "|"FAIR"||"GOOD"||"1"|"1"|"POOR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"||"Misc areas"|"0"|"0"|"0"|"1"|"1"|"1"|"POOR"|"1"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"0"|"1"|"0"||"1"|"0"||||"0"|"0"||"WARMING"||"1"||"FAIR"|"District is considering consolidated new elementary and closing Peterboro South Side "|"1620000"|"U"|"0"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 1:59:41 PM| 605|"East Syracuse-Minoa CSD"|"42040106"|"Central High School"|"0021"|"08/03/2010"|"FREMONT RD "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/2010"|"1965"|"232,800"|"1"|"12"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"1141"|"9,10,11,12"|"0"|"1"|"1"|"1141"|"0"|"0"|||"80"|"113,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"35"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"35"|"0"||"1"|"S"|"2002"|"35"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"20"|"10,000"|"Recommend adding wall packs near teacher parking"|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"35,000"|"Recommend reconfiguring swale near Technology parking lot"|"1"|"U"|"2002"|"5"|"18,000"|"Recommend replacing broken catch basin (front of building)"|"1"|"S"|"2002"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2003"|"5"|"350,000"|"Recommend replacing Technology/Loading Dock asphalt"|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"10"|"44,000"|"Recommend adding sidewalk @ D-wing"|"0"||||"0"||"1"|"E"|"2009"|"15"|"0"|"Y"|"Artificial turf updated w/ EXCEL funds"|"RECONCRETE,MASONCON"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"|"Minor cracks @ exterior corners (normal)"|"1"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"50"|"100,000"|"Re-configure walls for ADA compliance @ D & B wing toilet rooms"|"1"|"S"|"2002"|"10"|"0"|"Existing concealed spline ceiling are functional; re-support misc locations (maintenance)"|"1"|"S"|"2002"|"10"|"0"|"Existing lockers are functional; future painting recommended"|"1"|"U"|"S"|"2002"|"5"|"65,000"|"Recommend replacing approx. 22 wood doors & hardware (overall acceptable)"|"1"|"S"|"2002"|"50"|"0"||"1"|"U"|"2002"|"5"|"75,000"|"Recommend upgrading freight elevator (original & difficult to find parts)"|"1"|"1"|"U"|"2002"|"5"|"140,000"|"Recommend replacing remaining 1965 panels"|"1"|"E"|"2009"|"25"|"0"|"Updated w/ Energy Performance Contract"|"1"|"1"|"E"|"2009"|"15"|"0"|"PA/Clocks - Dukane MCS350, Pelco CCTV, Siemens Access Control, Toshiba Strata PBX"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"20"|"0"|"Auditorium & Media Center updated w/ EXCEL funds."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"20"|"63,000"|"Recommend abating VAT (misc classrooms); repair VCT issues @A wing/nurse/B2/B3/G wing"|"1"|"COMMON"|"S"|"2002"|"40"|"0"|"Minor cracks @ automotive classroom (no control joints) & terrazzo"|"1"|"INSTRUCT"|"U"|"2002"|"5"|"35,000"|"Recommend replacing stage floor"|"SLABGRADE,PRECAST"||"1"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2002"|"50"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"50"|"5,000"|"Recommend minor brick re-pointing (misc areas)"|"1"|"METAL"|"S"|"2009"|"30"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"20"|"9,000"|"Recommend replacing door near new gym (problematic)"|"1"|"S"|"2002"|"25"|"10,000"|"Recommend adding canopy @ ext. stairs - B2 wing"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"|"Updated w/ Energy Performance Contract / "Safe + Sound" project"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"|"Ballast deteriorating"|"U"|"2009"|"5"|"796,000"|"Recommend replacing A & B wing roofs"|"1"|"PLASTIC"|"S"|"2009"|"10"|"0"||"1"|"COPPER"|"S"|"2002"|"40"|"0"|"New water service & meters installed"|"1"|"IRON,COPPER"|"U"|"2002"|"5"|"79,000"|"Provide oil interceptor @ Technology drains; Replace sump pump; Replace Gym locker/Kitchen sanitary"|"1"|"NAT_GAS,ELECTRIC"|"S"|"2009"|"10"|"0"|"Natural gas @ Boiler Rm (B2) - 2002; Electric @ Nurse (B3) - 2009"|"1"|"U"|"2002"|"5"|"315,000"|"Recommend replacing original fixtures; Add eyewash @ Boiler Room."|"1"|"CV,OTHER"|"1"|"BOILERWATE"||"E"|"2009"|"35"|"0"|"Updated w/ Energy Performance Contract; w/ high efficiency motors "|"1"|"E"|"2009"|"35"|"0"||"1"|"S"|"2002"|"30"|"0"|"(2) air-cooled chillers @ ea boiler room"|"1"|"U"|"2002"|"5"|"840,000"|"Recommend replacing (8) original AHU's serving 1965 building"|"1"|"S"|"2009"|"35"|"0"||"1"|"S"|"2009"|"35"|"35,000"|"Recommend adding re-heat coils in interior zones for improved temp control"|"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"|"Edwards EST-3 point addressable system"|"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2009"|"15"|"26,000"|"Recommend adding corridor lighting to emergency generator; remove battery packs"|"1"|"S"|"2003"|"20"|"140,000"|"Recommend adding 2nd boiler rm, emergency lights, kitchen to system"|"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"1"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,COOKING,FRIDGE,SUMPPUMP,LIGHTING"|"FULL"||"1"||"GOOD"||"3,190,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"3156826180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 2:03:01 PM| 606|"Oneida City SD"|"25140001"|"New Transportation Building"|"5024"|"09/02/2010"|"205 East Avenue "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"2003"|"39680"|"2"|"0"|"0"|"PART"|"OTHER"|"Bus maintenance/transportation/train."|"0"|||"0"|"0"||||||"0"|"0"|"NONE,OTHER"|"Conference/training room"|"1"|"2"|"14000"|"0"|"0"|"S"|"2003"|"20"|"0"|"1 diesel (12,000); 1 gas (2,000)"|"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"|"New construction in 2003 as part of business park development"|"1"|"S"|"2003"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"25"|"0"|"New construction in 2003 as part of business park development"|"1"|"S"|"2003"|"20"|"0"|"Rip-rap stone lined channel"|"1"|"S"|"2003"|"25"|"0"|"New construction in 2003 as part of business park development"|"0"||||"0"||"1"|"MUNI"||"1"|"S"|"2003"|"25"|"0"|"Ties into municipal drainage system within business park"|"0"||||"0"||"0"||||"0"|"Drainage ties into municipal & discharges to basin owned/operated by City"|"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2003"|"10"|"80000"|"Seal concrete apron; re-stripe & seal asphalt cracks; consider adding bus parking"|"1"|"CONCRETE"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"45"|"0"||"1"|"S"|"2003"|"45"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"30"|"0"||"1"|"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"1"|"S"|"2009"|"8"|"0"|"New district wide VoIP telephone system"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"||"1"|"COMMON"|"S"|"2003"|"15"|"0"||"1"|"COMMON"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"45"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"45"|"0"||"1"|"METAL"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"20"|"0"||"0"|"S"|||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2003"|"25"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"80000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 2:04:44 PM| 607|"Rockville Centre UFSD"|"28022103"|"Watson Elementary School"|"0003"|"09/14/2010"|"277 North Centre Avenue"|"Rockville Centre"|" 11570"|"ANNUAL"|"04/01/2011"|"1953"|"26,638"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"264"|"K,1,2,3,4,5"|"0"|"0"|"0"|"264"|"0"|"0"|||"13"|"10400"|"ADMIN,AV,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"28"|"4,000"|"Repair tank alarm condition."|"1"|"MUN_UTILIT"|"S"|"1953"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"5"|"0"||"1"|"S"|"1953"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1953"|"5"|"0"||"1"|"S"|"1953"|"5"|"25,000"|"Provide additional drainage at bleacher & blacktop areas."|"0"||||"0"||"1"|"S"|"1953"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"0"||"1"|"CONCRETE"|"S"|"2005"|"15"|"3,600"|"Replace cracked sidewalk (200 sf)."|"1"|"S"|"1999"|"9"|"112,500"|"Replace base (5,625 sf), provide proper underlayment."|"1"|"S"|"2000"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1990"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1986"|"26"|"35,000"|"Provide lightning protection system."|"1"|"S"|"1980"|"5"|"650"|"Repair exterior canopy lighting timeclock."|"1"|"1"|"S"|"1987"|"5"|"233,500"|"Repalce PA/intercom system, provide wireless clock system, provide stage sound system, provide stage dimmer/theatrical lighting system, provide Smart Boards in remaining CR's (2) & provide ceiling projector in gym."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1990"|"20"|"0"||"1"|"COMMON"|"S"|"1990"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"20"|"0"|"Sand and refinish gym floor."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"20"|"0"||"0"|"MASONRY"|"S"|"1953"|"20"|"0"||"1"|"MASONRY"|"S"|"1953"|"20"|"0"||"S"|"S"|"0"|"1"|"1990"|"10"|"0"|"Replace 3 pairs of older exterior doors."|"1"|"S"|"1990"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1990"|"20"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1993"|"5"|"760,000"|"Consider roof replacement in Long Range Plan."|"1"|"GLASS"|"S"|"1993"|"5"|"0"||"1"|"COPPER"|"S"|"1985"|"25"|"0"||"1"|"IRON"|"S"|"1986"|"26"|"32,500"|"Repair/replace sewer line."|"1"|"NAT_GAS"|"S"|"1996"|"6"|"0"||"1"|"S"|"1953"|"5"|"23,500"|"Replace toilets in single BR's (10), provide vacuum breaker on slop sinks (2), add emergency eyewash to nurses sink."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1997"|"27"|"0"||"1"|"S"|"1997"|"27"|"0"||"1"|"S"|"1997"|"7"|"13,000"|"Repair leaks on Trane RTU, rebalance main office/reading suite AHU."|"1"|"S"|"1997"|"37"|"217,000"|"Extend UV sleeves, replace 27 leaking exhaust fans, remove abandoned central vacuum system, add cab heater in new wing hall & uncover 8 UV FAI's."|"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"7"|"90,000"|"Refurbish gym controls, replace Trane ATC system, ensure proper FAI for overheating 3 CR's."|"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"S"|"1986"|"5"|"0"||"0"||||"0"||"1"|"1"|"30,000"|"Upgrade door hardware for ADA compliance."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"0"|"0"|"FAIR"||"820,250"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/28/2010 2:08:50 PM| 608|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"WILDWOOD BLDG #13-HEAVY EQUIPMENT "|"0056"|"05/17/2010"|"1126 BALD HILL ROAD "|"HORNELL "|" 14843"|"ANNUAL"|"08/01/2011"|"1988"|"4252"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"38"|"9,10,11,12"|"0"|"0"|"0"|"38"|"0"|"0"|||"1"|"3750"|"TECHSHOP,OTHER"|"Maintenance Shop"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"|"Cost per building to install an exterior water storage tank (existing water system is inadequate). "|"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1988"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"13"|"0"|"New slurry seal is needed."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"10"|"20,000"|"Toilet rooms need updating."|"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1988"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1998"|"25"|"0"||"1"|"S"|"1988"|"5"|"10,500"|"Replace existing with T8 fixtures. "|"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1988"|"20"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"20"|"0"||"WOOD,OTHER"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1988"|"5"|"0"|"Metal siding was ripped off and damaged at various locations, fixed by Owner. "|"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"0"|"1988"|"2"|"30,000"|"Replace two (2) HM doors/frames on West elevation. "|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"NA"|"1988"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1988"|"15"|"0"||"1"|"COPPER"|"S"|"1988"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1988"|"5"|"0"|"Not ASME, provide tank-less gas water heater. "|"1"|"S"|"1988"|"5"|"5,600"|"Upgrade toilet rooms. "|"0"||"1"|"OTHER"||"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"1"|"S"|"1988"|"1"|"10,000"|"Add ventilation to toilet rooms. "|"0"||||"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"1988"|"5"|"2,000"|"Provide exterior egress lighting fixtures."|"0"||||"0"||"1"|"1"|"24,000"|"Upgrade toilet rooms. "|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"POOR"|"0"|"POOR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"|||"0"|"1"|"0"|"FAIR"||"49,100"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/28/2010 2:16:54 PM| 609|"Oneida City SD"|"25140001"|"Maintenance Warehouse"|"3012"|"08/27/2010"|"565 SAYLES ST "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1950"|"5,000"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Storage and Maintenance Shop"|"0"|"OTHER"|"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"|"Fed from H.S."|"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"|"Fed from H.S."|"1"|"UTIL"|"BELOW"|"S"|"2003"|"30"|"0"|"fed from Power Shop Annex"|"1"|"E"|"2009"|"30"|"0"|"Parking areas sheet drain to Power Annex/HS infrastructure. "|"0"||||"0"||"1"|"S"|"2009"|"30"|"0"|"Parking areas sheet drain to Power Annex/HS infrastructure. "|"0"||||"0"||"0"|"SURFACEH2O,OTHER"|"Higinbotham Brook"|"1"||||"0"|"Drainage ties into HS infrastructure, which discharges to Higinbotham Brook."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"30"|"0"|"Parking areas paved w/ 2009 Capital project/Excel Funds"|"1"|"ASPHALT"|"E"|"2009"|"30"|"0"|"Sidewalks paved w/ 2009 Capital project/Excel Funds"|"0"||||"0"||"0"||||"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1980"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"|"n/a"|"0"||||"0"|"n/a"|"1"|"S"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 new district-wide VOIP telephone system"|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1950"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"15"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1950"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"U"|"S"|"0"|"1"|"2004"|"5"|"15,000"|"Recommend replacing (2) overhead doors."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1950"|"10"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1950"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"25"|"0"||"1"|"ELECTRIC"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2003"|"15"|"0"|"Gas-fired unit heaters"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"|"Unit Heaters. No piping system except for gas."|"1"|"S"|"2003"|"15"|"0"|"Gas unit heaters."|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"|"n/a"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"0"|"0"|"FAIR"||"15,000"|"S"|"1"|"King + King Architects"|"358 West Jefferson Street, Syracuse, NY 13209"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 2:17:31 PM| 611|"Holland Patent CSD"|"41220106"|"Garage and Shop and Annex"|"0004"|"08/20/10"|"9601 Main Street"|"Holland Patent "|" 13354"|"ANNUAL"|"10/01/2011"|"1936"|"17480"|"1"|"0"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER,OTHER_ORG"|"board meetings, staff development"|"0"|||"0"|"1"||||||"0"|"0"|"NONE,ADMIN,OTHER"|"Conference, Maintenance shop"|"1"|"0"|"0"|"1"|"1000"|"S"|"1936"|"0"|"50000"|"Remove abandoned underground tank and provide a 250 gallon above ground one in boiler room"|"1"|"MUN_UTILIT"|"S"|"1957"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"25"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"OTHER"|"BELOW"|"S"|"2002"|"25"|"0"|"fed from Middle School, 2 services"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"|"all site items considered part of Elementary and MS sites"|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"1936"|"15"|"10000"|"patch hairline crack in foundation wall (may be causing water infiltration into building)"|"1"|"S"|"1936"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2009"|"24"|"0"||"0"||||"0"||"1"|"S"|"S"|"1995"|"5"|"0"||"1"|"S"|"1936"|"10"|"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"5"|"12000"|"Replace panels in old bus garage portion of building"|"1"|"S"|"2005"|"5"|"17000"|"Replace T-12 in old bus garage portion of building"|"1"|"1"|"S"|"2005"|"10"|"0"|"Connected to Middle School P.A. system"|"0"||||"0"||"1"|"COMMON"|"S"|"2006"|"11"|"100000"|"district office needs to be replaced (1995)"|"1"|"COMMON"|"S"|"2006"|"15"|"0"||"1"|"COMMON"|"S"|"1995"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1936"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"0"||"S"|"1936"|"15"|"6000"|"Re-point section of brick (may be causing water infiltration into building)"|"1"|"MASONRY"|"S"|"1936"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1995"|"5"|"0"||"0"||||"17000"|"Provide a set of stairs with railing from existing exterior door"|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"U"|"NA"|"2002"|"22"|"61000"|"Replace 1936 steel windows (7 total)"|"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"roof drains are connected to floor drains"|"S"|"2005"|"15"|"0"||"0"|||||"0"||"1"|"IRON"|"S"|"2002"|"0"|"5000"|"Insulate 200 lf. hot water domestic piping."|"1"|"IRON"|"S"|"1957"|"5"|"3000"|"Exploratory scope underground san. & repair for backups in office area."|"1"|"NAT_GAS"|"S"|"1992"|"0"|"17000"|"Replace hot water heater"|"1"|"S"|"2002"|"25"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2005"|"25"|"0"||"1"|"S"|"2009"|"25"|"0"||"1"|"S"|"2010"|"12"|"0"|"Rooftop DX units"|"1"|"S"|"2002"|"15"|"1000"|"Toilet room exhaust and controls required"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"5"|"35000"|"Replace with dedicated panel, take off MS system"|"1"|"S"|"2002"|"5"|"17000"|"Replace with addressable smoke/heat detectors"|"0"||||"0"||"1"|"S"|"2002"|"10"|"3000"|"Add additional emergency lighting per new code"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"|"no classrooms in this building"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"352000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 2:26:42 PM| 614|"Cobleskill-Richmondville CSD"|"54110206"|"George D. Ryder Elementary"|"0002"|"10/21/2010"|"142 Golding Drive "|"COBLESKILL "|" 12043"|"ANNUAL"|"01/01/2011"|"1958"|"132800"|"2"|"5"|"1"|"DISTRICT"|"INSTRUCT"||"557"|"K,1,2,3,4,5"|"0"|"1"|"1"|"557"|"0"|"0"|||"56"|"60321"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"2"|"3500"|"0"|"0"|"E"|"2009"|"20"|"0"|"Generator diesel tanks, remove abandonded tank from shelter"|"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"0"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"20"|"0"||"1"|"CONCRETE"|"S"|"2003"|"5"|"10000"|"Replace section of sidewalk at cafeteria entrance, addition"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"|"N"|"Bleachers replaced 2008"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"40"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"|"Original cafeteria ceiling near end useful life. Majority of ceiling replaced 2003."|"1"|"U"|"1969"|"6"|"0"|"shelter gym lockers in poor condition but currently not being used."|"1"|"S"|"S"|"2003"|"5"|"15000"|"Some original 1958 hardware remaining at classroom closets, toilet rooms, some offices, 15,000, recommend adding closers to corridor doors."|"1"|"S"|"2003"|"15"|"0"|"Rubber stair tread replacement approx 15 years"|"1"|"S"|"2003"|"20"|"0"|"Material lift installed 2009"|"1"|"1"|"S"|"2003"|"20"|"0"|"Recommend TVSS protection for computers"|"1"|"S"|"2004"|"5"|"28000"|"Cafeteria, stage 7,000, Gymnasium lighting 21,000, near end useful life, poor lighting in basement"|"1"|"1"|"S"|"2004"|"15"|"0"|"Original wiring for clock system"|"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"10"|"0"|"Library, offices 2003, Main office 2009"|"1"|"INSTRUCT,COMMON"|"S"|"2003"|"10"|"0"|"Some 1958 VAT remaining throughout original classrooms"|"1"|"INSTRUCT,COMMON"|"S"|"2003"|"20"|"0"||"1"|"COMMON"|"S"|"2003"|"20"|"0"|"Ryder and Shelter gym floors"|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2003"|"5"|"5000"|"Cracks in brick veneer and plaster in 1958 vintage adjacent to main office at expansion joint, recommend monitoring to assess."|"1"|"MASONRY"|"S"|"1958"|"2"|"10000"|"Remove abandoned chimney from former Shelter boiler room."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"5"|"15000"|"Replace 2 pairs exit doors in music wing"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"15"|"0"|"Original vintage replaced in 1989"|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"10"|"0"|"Spray foam installed 2004, re-coat recommended 2015-2020"|"1"|"GLASS"|"S"|"1989"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"IRON,GALVANIZED"|"S"|"2004"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2004"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"|"fixtures in original Shelter and ryder K3 building - functioning but near expected life"|"0"||"1"|"GEOTHERMAL"||"S"|"2004"|"10"|"0"|"Replacement of heat pumps approx 2020"|"1"|"S"|"1968"|"10"|"0"|"LP gas should be replaced with natural gas distribution"|"1"|"S"|"2004"|"15"|"0"|"Geothermal heat pumps, see above"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2003"|"20"|"0"|"Add notification devices to basement, 2,500"|"1"|"S"|"2003"|"20"|"0"|"Add notification devices to basement, 2,500"|"1"|"S"|"1992"|"1992"|"0"|"Kitchen ansul system in hood scheduled for replacement 2011"|"1"|"S"|"2004"|"2"|"2000"|"Replace emergency exit signs in K3 cafeteria"|"1"|"E"|"2009"|"20"|"0"||"1"|"1"||"Knob door hardware"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"Gym - fair, Cafeteria - poor"|"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"||"Stained ceiling tile at Ryder, Shelter gym exit corridor"|"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"1"|"AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"1"|"0"|"GOOD"||"115000"|"S"|"0"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/28/2010 2:44:00 PM| 615|"Duanesburg CSD"|"53010104"|"High/Middle School"|"0001"|"08/20/2010"|"133 School Drive "|"DELANSON "|" 12053"|"ANNUAL"|"06/01/2011"|"1934"|"91,754"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"495"|"6,7,8,9,10,11,12"|"0"|"1"|"1"|"495"|"0"|"0"|||"17"|"13,400"|"ADMIN,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"0"|"0"|"1"|"10,000"|"E"|"1988"|"20"|"0"|"Primary fuel"|"1"|"MUN_UTILIT"|"S"|"2003"|"43"|"0"||"1"|"MUN_UTILIT"|"E"|"2003"|"43"|"0"|"Minor renewal (Faucets and Fixtures etc)"|"1"|"E"|"2006"|"44"|"0"|"Propane for science and boiler pilots."|"1"|"UTIL"|"BELOW"|"S"|"2007"|"6"|"34,000"|"Some distribution needs to be upgraded. (Lighting 50% of building/New feeders to Tech Dept #359,000) (Lighting in Gym & Multipurpose to T8 $15,000)"|"1"|"U"|"1963"|"50"|"236,000"|"Major improvements required to prevent building from flooding."|"1"|"S"|"2000"|"90"|"0"||"1"|"U"|"1963"|"53"|"1,000"|"Good condition, but inadequate size."|"1"|"S"|"1963"|"53"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"1963"|"53"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,OTHER"|"U"|"2008"|"3"|"673,000"|"South lot paved (was gravel). Unsafe traffic patterns exist."|"1"|"CONCRETE,ASPHALT"|"U"|"2000"|"3"|"6,000"|"Concrete walks are deteriorating and spalling."|"0"||||"0"||"1"|"S"|"2009"|"10"|"8,000 drainage"|"N"|"Needs accessibility upgrade. Baseball field dugouts need work."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"26"|"0"||"1"|"S"|"2000"|"40"|"0"||"1"|"S"|"2000"|"40"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"U"|"2000"|"3"|"8,000"|"1964 Lockers should be painted - retrofitted with new locks."|"1"|"U"|"U"|"2000"|"2"|"25,000"|"Accessibility of doors needs some upgrade along common routes."|"1"|"S"|"2000"|"40"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"0"|"U"|"2000"|"3"|"35,000"|"Replace panels and distribution upgrade."|"1"|"U"|"2000"|"5"|"5,000"|"Kitchen needs new lighting."|"1"|"1"|"S"|"2009"|"9"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"U"|"2000"|"2"|"10,000"|"Should all be replaced. Recarpet in distance learning. Change out to hard floors other places."|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"5"|"0"||"1"|"COMMON"|"S"|"2000"|"90"|"0"||"1"|"COMMON"|"S"|"2000"|"40"|"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"26"|"0"||"MASONRY"|"0"|"0"|"Bad flashing."|"0"|"0"|"0"|"1"|"0"||"U"|"2000"|"2"|"72,000"|"Replace flashing and upgrade cladding on upper gym wall/leaks."|"1"|"MASONRY"|"S"|"1964"|"53"|"0"||"1"|"MASONRY"|"U"|"2000"|"4"|"71,000"|"Crown and coping on 1934 section is deteriorated."|"S"|"S"|"0"|"1"|"2000"|"11"|"0"||"1"|"U"|"2000"|"4"|"20,000"|"Stairs to upper parking lot unsafe."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2000"|"3"|"127,000"|"1980's windows in 1934 building section at end of useful life."|"METONMET,WOODONMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"1"||"U"|"2000"|"0"|"611,000"|"1964 era roofs failing. Joint to gym upper roof leaking."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2000"|"40"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"2000"|"40"|"0"||"1"|"OIL"|"U"|"2000"|"3"|"11,000"|"Shoule relocate old 1935 unit to consolidate into 1965 Mechanical Room."|"0"|"S"|"2000"|"9"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2000"|"9"|"0"||"1"|"S"|"2000"|"9"|"0"||"0"|"S"|"2000"|"6"|"0"|"Gym and Main Offices only."|"1"|"S"|"1996"|"6"|"0"||"1"|"S"|"2000"|"11"|"0"||"1"|"S"|"2000"|"11"|"0"||"1"|"U"|"2000"|"4"|"134,000"|"Pnumatics maintenance difficult and inefficient."|"0"|"S"|"2000"|"11"|"0"||"0"|"S"|"2000"|"11"|"0"||"1"|"U"|"2000"|"2000"|"25,000"|"Should install stand pipe and hose cabinets in stairs."|"1"|"S"|"2000"|"4"|"0"||"0"||||"0"|"Should add emergency backup to boiler system."|"1"|"0"|"48,000"|"Lavatories are not fully accessible."|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"1"|"CLASSROOMS,HALLWAYS"||"0"|"0"|"36,000"|"Work includes ventilation upgrades."|"1"|"1"|"0"|"0"|"0"|"1"|"POOR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"FAIR"|"Roof and drain work is proposed to alleviate moisture infiltration."|"1"||"1"|"0"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||"FULL"||"1"||"FAIR"|"No assembly space of adequate size. Not enough classrooms."|"5,800,000"|"U"|"1"|"Synthesis Architects, LLP"|"162 Jay Street, Schenectady, New York 12305"|"518-370-1576"|"rdefranco@synthesisllp.com"|"John Senisi"|"020640"|"I ACCEPT"|12/28/2010 2:45:33 PM| 616|"Oneida City SD"|"25140001"|"New Transportation Storage"|"5025"|"09/02/2010"|"205 EAST AVENUE"|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"2003"|"28536"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus storage"|"0"|||"0"|"0"||||||"0"|"0"|"NONE,OTHER"|"Bus storage"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"|"New construction in 2003 as part of business park development"|"1"|"S"|"2003"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"30"|"0"|"Fed from adjacent Bus Maintenance Garage."|"1"|"S"|"2003"|"25"|"0"|"New construction in 2003 as part of business park development"|"0"||||"0"||"1"|"S"|"2003"|"25"|"0"|"New construction in 2003 as part of business park development"|"0"||||"0"||"1"|"MUNI"||"1"|"S"|"2003"|"25"|"0"|"Ties into municipal drainage system within business park"|"0"||||"0"||"0"||||"0"|"Drainage ties into municipal which discharges to basin owned/operated by City"|"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2003"|"10"|"10000"|"Seal concrete aprons; seal asphalt cracks; re-stripe parking lines"|"1"|"CONCRETE"|"S"|"2003"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"50"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"1"|"S"|"2009"|"8"|"0"|"2009 new district wide VoIP telephone system"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2003"|"15"|"0"||"1"|"COMMON"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"50"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"50"|"0"||"1"|"METAL"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2003"|"25"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"OTHER"|"Unit Ventilation"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"10000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 2:52:21 PM| 617|"BOCES Cayuga-Onondaga"|"05900000"|"Summit School at Auburn YMCA"|"0003"|"11/9/10"|"29 William Street"|"Auburn"|" 13021"|"ANNUAL"|"9/1/2011"|"1930"|"10500"|"3"|"0"|"0"|"LSD_DIST"|"INSTRUCT"||"75"|"7,8,9,10,11,12"|"0"|"0"|"0"|"75"|"0"|"0"|||"10"|"5400"|"ADMIN,GUIDANCE,GYM,KITCHEN,POOL"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"15"|"0"||"1"|"S"|"1930"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"15"|"0"||"1"|"CONCRETE"|"S"|"1990"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"15"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"8"|"0"||"1"|"S"|"1996"|"6"|"0"||"1"|"S"|"2001"|"14"|"0"||"1"|"S"|"S"|"1996"|"10"|"0"||"1"|"S"|"1980"|"15"|"0"||"1"|"S"|"1980"|"15"|"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"1"|"S"|"2010"|"10"|"0"|"Speaker system installed in 2010 for lockdown announcement"|"1"|"S"|"1990"|"15"|"0"|"Swimming pool is part of the YMCA space. The Summit program is allowed usage at certain prescribed times for students physical education requirement."|"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1996"|"10"|"0"||"1"|"COMMON"|"S"|"1996"|"10"|"0"||"0"|||||"0"||"OTHER"|"Reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1935"|"15"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1935"|"15"|"0"||"1"|"MASONRY"|"S"|"1960"|"15"|"0"||"1"|"MASONRY"|"S"|"1960"|"15"|"0"||"S"|"S"|"0"|"1"|"1990"|"15"|"0"||"1"|"S"|"1990"|"15"|"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"Y"|"1990"|"15"|"0"||"OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"5"|"0"|"Summit School is leasing space in this building. YMCA would be responsible for any roof repair cost."|"0"|||||"0"||"1"|"COPPER"|"S"|"1996"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1996"|"5"|"12000"|"Replace individual window air conditioning units"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"FAIR"||"1"|"0"|"0"|"0"|"0"|"0"|"0"||"0"|"0"||"0"||"0"|"0"||||"0"|"0"|"FAIR"||"12000"|"S"|"1"|"Samuel J. Cichello, Architect"|"2714 Franklin Street, Weedsport, NY 13166"|"315-689-7090"|"sjcarch@gmail.com"|"Samuel J. Cichello"|"007611"|"I ACCEPT"|12/28/2010 2:55:53 PM| 618|"Minisink Valley CSD"|"44110104"|"High School"|"0005"|"05/12/2010"|"2320 Route 6, Building 2 "|"SLATE HILL "|" 10973"|"ANNUAL"|"03/01/2011"|"1974"|"123758"|"2"|"11"|"0"|"DISTRICT"|"INSTRUCT"||"1580"|"9,10,11,12"|"0"|"1"|"1"|"1580"|"0"|"0"|||"46"|"35545"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"1"|"1000"|"0"|"0"|"S"|"2000"|"30"|"0"|"Fuel tank appears to be in satisfactory condition."|"1"|"WELL"|"S"|"1999"|"40"|"0"||"1"|"OTHER"|"S"|"2000"|"50"|"0"||"1"|"S"|"2008"|"20"|"0"|"Gas service appears to be in satisfactory condition."|"1"|"UTIL"|"BELOW"|"S"|"1973"|"13"|"0"||"1"|"S"|"2004"|"44"|"25,000"|"Add 1050 lf of perforated underdrain along northern and southern perimeter of building"|"0"||||"0"||"1"|"S"|"2004"|"44"|"0"||"1"|"S"|"2004"|"44"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2004"|"44"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2010"|"30"|"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1973"|"2"|"576000"|"Replace drive isles from Rte 6 to school. Replace paving in main parking area in front of building (approx 12780 sq yds)."|"1"|"CONCRETE"|"S"|"1973"|"2"|"130000"|"Replace all concrete sidewalks in front of school (approx 18000 sf)."|"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"2010"|"50"|"517000"|"N"|"baseball field grading (remove outfield drop-off) $42,000; replace dugouts $200,000; refurbish 6 tennis courts $210,000; remove old water tanks $40,000; new fencing along Route 6 $25,000."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"91"|"0"||"1"|"S"|"2001"|"71"|"0"||"1"|"S"|"2001"|"71"|"0"||"1"|"S"|"2001"|"16"|"616000"|"Classroom ceilings in orig bldg are old painted grid and tile and in need of replacement. (Cost includes lighting and electrical items to be included)."|"1"|"S"|"2001"|"31"|"0"||"1"|"S"|"S"|"2001"|"26"|"100000"|"Two electrically operated accordion partitions in Auditorium are worn and in need of replacement."|"1"|"S"|"2001"|"71"|"0"||"1"|"S"|"1974"|"44"|"0"||"1"|"1"|"S"|"1973"|"13"|"0"||"1"|"E"|"2010"|"30"|"0"||"1"|"1"|"S"|"2010"|"20"|"190000"|"Replace entire PA system (past useful life $150,000; Replace entire clock system (past useful life) with wireless (primex) system $60,000."|"1"|"S"|"2000"|"20"|"61000"|"Refinish two existing diving board stands $1,000; Regrout pool shell with an epoxy based grout $60,000."|"1"|"INSTRUCT"|"S"|"2001"|"11"|"0"||"1"|"INSTRUCT"|"S"|"2001"|"11"|"0"||"1"|"COMMON"|"S"|"1974"|"11"|"0"||"1"|"COMMON"|"S"|"1974"|"1"|"9,000"|"Refinish wood stage floor (stage and apron)."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"71"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"66"|"0"||"1"|"MASONRY"|"S"|"2001"|"66"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"35"|"0"||"1"|"S"|"2001"|"21"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2010"|"30"|"0"||"METONMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"10"|"0"||"1"|"PLASTIC"|"S"|"2001"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1999"|"30"|"0"||"1"|"IRON,COPPER"|"S"|"1999"|"30"|"0"||"1"|"NAT_GAS"|"S"|"2010"|"15"|"0"||"1"|"E"|"2010"|"30"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2010"|"25"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2000"|"10"|"0"|"Original 1973 equipment nearing end of useful life. See Iten 78 for more information."|"1"|"S"|"2000"|"10"|"2,100,000"|"Some orig equip was not replaced in 2000 project and nearing end of useful life. Replace Library, Cafeteria, Stage, (2) Auditorium and Main Office rooftop units currently providing heat, cool and vent air. Cost incl elec and arch required work."|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"25"|"0"|"2000 system in excellent shape, orig buldign equipment is nearing end of useful life. Refer to Item 78."|"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"E"|"2010"|"15"|"0"||"1"|"S"|"2010"|"30"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"1"|"0"|"1"|"GOOD"||"5621200"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/28/2010 3:02:44 PM| 619|"Rockville Centre UFSD"|"28022103"|"William Covert Elementary School"|"0008"|"09/15/2010"|"379 Willow Street"|"South Hempstead"|" 11550"|"ANNUAL"|"04/01/2011"|"1952"|"32891"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"316"|"K,1,2,3,4,5"|"0"|"1"|"0"|"316"|"0"|"0"|||"16"|"12800"|"ART,COMPROOM,HLTHSUITE,KITCHEN,MULTIPURPO,MUSIC,REMEDIAL,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"28"|"1,500"|"Provide signage & cage at overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1952"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1952"|"5"|"0"||"1"|"S"|"2003"|"43"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"43"|"0"||"1"|"S"|"1952"|"5"|"0"||"0"||||"0"||"1"|"S"|"1952"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"12,850"|"Repair asphalt at NW corner and in Long Beach Road loop."|"1"|"CONCRETE"|"S"|"2005"|"15"|"24,650"|"Repalce settling sidewalk at loop (800 sf), widen pickup walkway, widen fence gate and move landscaping wall and bushes (100 sf)."|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"1952"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1992"|"10"|"0"||"1"|"S"|"1952"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1986"|"26"|"35,000"|"Provide lightning protection system."|"1"|"S"|"2003"|"13"|"56,000"|"Replace missing lenses in room 113 & ESL room, replace auditorium dimmer system, provide sleeves on exposed stage lighting, repair exterior clock, add speakers to several rooms, provide additional outside telephone lines."|"1"|"1"|"S"|"2009"|"19"|"103,500"|"Replace auditorium sound system, provide wireless clock system, provide Smart Boards in remaining rooms (6 total)."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1992"|"20"|"0"||"1"|"COMMON"|"S"|"1992"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1992"|"20"|"0"|"Sand & refinish classroom floors."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"20"|"0"|"Tuckpoint weathered masonry."|"1"|"MASONRY"|"S"|"1952"|"20"|"0"||"1"|"MASONRY"|"S"|"1992"|"20"|"0"||"S"|"S"|"0"|"1"|"1992"|"10"|"0"|"Replace older exterior doors."|"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1"|"1992"|"20"|"0"|"Replace damaged roof planks."|"1"|"ALUMINUM"|"S"|"Y"|"1988"|"10"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1992"|"10"|"890,000"|"Consider replacement in Long Range Plan."|"0"|||||"0"||"1"|"COPPER"|"S"|"1952"|"5"|"0"||"1"|"IRON"|"S"|"1952"|"5"|"13,000"|"Clear roof vents and add caps."|"1"|"NAT_GAS"|"S"|"2003"|"13"|"0"||"1"|"S"|"1952"|"5"|"3000"|"Add emergency eyewash in nurse/custodial areas."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"33"|"0"||"1"|"S"|"2003"|"33"|"0"||"1"|"S"|"2003"|"13"|"279,500"|"Add chiller to A/C all CR's, add A/C to library wire closet and replace old York condensing unit on roof."|"1"|"S"|"2003"|"43"|"129,400"|"Replace 5 rooftop exhaust fans, provide FAI for rooms 105, 106/07, social worker's office, ESL, 125A & 127, remove basement central vacuum system, clean RA grilles on stage, add ventilation to Principal's office area."|"1"|"S"|"2003"|"43"|"0"||"0"|"S"|"2003"|"43"|"13,000"|"Replace duct insulation on gym & auditorium RTU's."|"1"|"S"|"2003"|"13"|"38,500"|"Replace Trane EMS with Johnson Controls EMS."|"1"|"S"|"2003"|"13"|"000"||"1"|"S"|"2003"|"13"|"0"||"0"|"S"|||"0"||"1"|"S"|"1986"|"5"|"0"||"0"||||"0"||"1"|"1"|"36,000"|"Upgrade knobs to levers at doors."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"0"|"0"|"FAIR"||"1,635,900"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/28/2010 3:02:53 PM| 622|"Perry CSD"|"67120106"|"Elem./MS"|"0005"|"05/08/2010"|"50 Olin Ave."|"Perry"|" 14530"|"ANNUAL"|"06/11/2011"|"2000"|"154,466"|"2"|"2"|"0"|"DISTRICT"|"INSTRUCT"||"649"|"Pre-K,K,1,2,3,4,5,6,7,8"|"0"|"1"|"0"|"649"|"0"|"0"|||"42"|"34,650"|"ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"5"|"34,000"|"Install asphalt pavement on drive at rear of school."|"1"|"ASPHALT"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"5"|"125,000"|"New UPK playground."|"1"|"S"|"2008"|"10"|"0"|"Y"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"25"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"1"|"S"|"2000"|"15"|"175,000"|"Additional receptacles in classrooms."|"1"|"S"|"2000"|"15"|"75,000"|"Upgrade lighting in Gymnasium, stairwells and install occupancy sensors."|"1"|"1"|"S"|"2000"|"15"|"240,000"|"Upgrade data system; upgrade security system; replace clock system."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2000"|"2"|"10,000"|"Replace carpet in select classrooms."|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"2000"|"5"|"200,000"|"Install polished concrete floors at corridors."|"1"|"COMMON"|"S"|"2000"|"20"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"15"|"80,000"|"Replace exterior window sills."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"50,000"|"Miscellaneous repairs."|"1"|"PLASTIC"|"S"|"2000"|"10"|"Inc. in number 68 U."||"1"|"COPPER"|"S"|"2000"|"15"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"2000"|"15"|"30,000"|"Replace grease trap in Kitchen."|"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"15"|"80,000"|"Revise Gymnasium ductwork; install UV lights in AHUs."|"1"|"S"|"2000"|"15"|"8,000"|"Install fin tube at Nurses' area."|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"10"|"39,000"|"Upgrade control systems."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"15"|"1,500"|"Upgrade emergency lighting."|"1"|"S"|"2000"|"5"|"100,000"|"Extend emergency power feed to UPS."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"1"|"FIREALARM,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"1,247,500"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/28/2010 3:10:20 PM| 624|"Johnstown City SD"|"17060001"|"Field House Toilets"|"0039"|"07/14/2010"|"1 Sir Bills Circle"|"Johnstown"|"12095-2030"|"ANNUAL"|"01/01/2011"|"2006"|"400"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"toilet facility"|"0"||"0"|"0"|"0"||||||"0"|"0"|"OTHER"|"toilet rooms"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"50"|"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"50"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2006"|"50"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"20"|"0"||"1"|"ASPHALT"|"E"|"2006"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"30"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2006"|"50"|"0"||"1"|"E"|"2006"|"50"|"0"||"1"|"E"|"2006"|"50"|"0"||"1"|"E"|"2006"|"50"|"0"||"0"||||"0"||"0"||||"0"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2006"|"50"|"0"||"1"|"S"|"2006"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2006"|"50"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2006"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2006"|"50"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2006"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2006"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2006"|"20"|"0"||"1"|"IRON"|"E"|"2006"|"20"|"0"||"1"|"ELECTRIC"|"E"|"2006"|"10"|"0"||"1"|"E"|"2006"|"10"|"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"1"|"E"|"2006"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"E"|"0"|"Bonacci Architects pllc"|"6320 Fly Road, East Syracuse NY 13057"|"3154372636"|"studio@bonacci-architects.com"|"David J. Bonacci"|"015803"|"I ACCEPT"|12/28/2010 3:19:22 PM| 625|"North Colonie CSD"|"01062306"|"Southgate"|"0006"|"10/08/2010"|"30 Southgate Road"|"Loudonville"|"12211"|"ANNUAL"|"01/01/2011"|"1955"|"57430"|"1"|"2"|"2"|"DISTRICT"|"INSTRUCT"||"421"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"421"|"0"|"0"|||"21"|"18660"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"15"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1991"|"10"|"0"|"Utility vault."|"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"MUNI"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1991"|"10"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"50000"|"Remove gym op partition. Replace with curtain."|"1"|"S"|"2004"|"10"|"0"|"ACM plaster soffits and conceal spline."|"0"||||"0"||"1"|"S"|"S"|"2004"|"10"|"50000"|"Original vintage - non rated/ADA."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"|"Gym lights replaced 2009."|"1"|"1"|"S"|"1997"|"10"|"35000"|"Convert clocks to GPS."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2004"|"10"|"280000"|"VAT at cafeteria and classrooms, cracks at CR 117 VCT."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"20"|"0"|"Crack at cor terrazzo."|"1"|"INSTRUCT,COMMON"|"S"|"1955"|"10"|"0"||"SLABGRADE,OTHER"|"mezzanine-concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2010"|"10"|"75000"|"1991 panels being replaced, abate caulk paint 1955 panels."|"1"|"MASONRY"|"S"|"2009"|"20"|"0"|"Pointed, sealed 2009."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"10"|"0"|"Corruded aluminum track at replaced units (2 locations)."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"70000"|"1991 wing original roof."|"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2004"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"2004"|"10"|"75000"|"Main cor fixtures replace for ADA."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2010"|"20"|"0"|"Two unilux boilers."|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2004"|"10"|"40000"|"Window units and AC splits. Provide AC to Library."|"1"|"S"|"2010"|"20"|"0"|"Classroom UVS 2010, gym and cafeteria 2004"|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2010"|"10"|"0"|"Combination pneumatic - electric DDC."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"15000"|"Upgrade emergency lights."|"1"|"S"|"2009"|"20"|"0"|"Milton-CAT 75 kw gas generator."|"1"|"1"|"5000"|"Auto door opener."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"0"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|"WARMING"|"0"|"1"||"GOOD"||"790000"|"S"|"1"|"CSArch"|"40 Beaver St., Albany, NY 12207"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I ACCEPT"|12/28/2010 3:20:37 PM| 626|"Oneida City SD"|"25140001"|"North Broad Street Elementary"|"0005"|"08/27/2010"|"230 NORTH BROAD ST "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1912"|"35568"|"3"|"2"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"241"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"241"|"0"|"0"|||"26"|"17000"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,TEACHRSRC"||"0"||||||"2009"||"0"|"Removed 4k gal underground tank w/ EXCEL funds."|"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"4000"|"Recommend replacing chain-link fence @ meter"|"1"|"UTIL"|"BELOW"|"S"|"1989"|"20"|"5000"|"Recommend chain-link fence @ transformer"|"1"|"E"|"2009"|"25"|"0"|"Drainage infrastructure replaced 2003/2009"|"0"||||"0"||"1"|"E"|"2009"|"25"|"0"|"Drainage infrastructure replaced 2003/2009"|"0"||||"0"||"0"|"MUNI,ONSITE"||"1"||||"0"|"Drainage infrastructure ties into municipal system"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2009"|"25"|"0"|"Parking areas & roadways reconstructed w/ EXCEL funds."|"1"|"CONCRETE"|"E"|"2009"|"20"|"0"|"New sidewalks & curbs w/ EXCEL funds."|"1"|"E"|"2009"|"10"|"0"|"Portion of existing playscape upgrade (ADA compliance) w/ EXCEL funds."|"1"|"S"|"2003"|"15"|"0"|"N"|"No formal play fields, open lawn only."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"30"|"0"|"Routine inspections"|"1"|"1"|"S"|"2009"|"30"|"0"|"Replaced branch wiring @ '12 wing; new elec panels @ technology; new panel boards"|"1"|"S"|"2004"|"25"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 - district wide VoIP telephone (8yr lifespan); PA (15yr lifespan)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1912"|"15"|"0"|"Ongoing maintenance (sealing)"|"SLABGRADE,WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2004"|"25"|"0"||"1"|"MASONRY"|"S"|"2004"|"25"|"0"||"1"|"MASONRY"|"S"|"2004"|"25"|"0"||"S"|"S"|"0"|"1"|"2004"|"5"|"15000"|"Recommend replacing (4) exterior doors/frames/hardware (corroded)"|"1"|"S"|"2004"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"25"|"0"||"METONMET,WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"1"|"PLASTIC"|"S"|"2004"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,GALVANIZED,COPPER,PVC"|"S"|"2003"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"|"District is considering building consolidation, which may affect this building"|"24000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 3:24:10 PM| 628|"Stockbridge Valley CSD"|"25150104"|"Ag LAB Facility"|"0014"|"9/1/10"|"6011 WILLIAMS ROAD "|"MUNNSVILLE "|" 13409"|"ANNUAL"|"11/1/11"|"1998"|"960"|"1"|"0"|"1"|"DISTRICT"|"INSTRUCT"|"Maple Syrup Production and Greenhouse"|"150"|"UNGRD"|"0"|"1"|"0"|"0"|"0"|"150"|"OTHER"|"Maple Syrup Production and Greenhouse"|"0"|"0"|"OTHER"|"Ag Lab/Greenhouse"|"1"|"1"|"250"|"0"|"0"|"S"|"1998"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"10"|"0"||"1"|"SITESEPT"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"3000"|"Consider adding fence at exterior propane tank"|"1"|"UTIL"|"ABOVE"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2005"|"10"|"0"||"1"|"CONCRETE"|"S"|"1998"|"5"|"1000"|"Pads outside doors"|"0"||||"0"||"0"||||"0"|||"MASONCON,OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"S"|"1998"|"15"|"0"|"Concrete masonry at boiler room"|"0"|"S"|||"0"|"Exposed structure"|"0"||||"0"||"1"|"S"|"S"|"1998"|"5"|"2000"|"1 door to boiler"|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1998"|"5"|"20000"|"increase upgrade interior outlets and branch circuiting"|"1"|"S"|"1998"|"5"|"25000"|"upgrade to latest lam ballast technology wauto controls"|"1"|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1998"|"15"|"0"|"sealed concrete"|"0"|"INSTRUCT"||||"0"||"SLABGRADE,OTHER"|"gravel at greenhouse"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"15"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"10"|"0"|"metal framed greenhouse"|"1"|"METAL"|"S"|"1998"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"5"|"14000"|"replace exterior doors"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"10"|"6000"|"Existing windows are not energy efficient Recommend replacement"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"5"|"20000"|"Replace polycarbonate roof panels at Greenhouse and shingle roof on Ag Lab"|"0"|||||"0"||"1"|"COPPER"|"S"|"1998"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1998"|"20"|"0"||"1"|"OTHER"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1998"|"5"|"30000"|"Serves adjacent Greenhouse natural gas fired Utica Boiler Add 2nd boiler to provide back-up as well as for heating of Lab Remove Gas Heater from Lab"|"1"|"S"|"1998"|"10"|"0"|"natural gas"|"0"||||"0"||"1"|"S"|"1998"|"7"|"0"||"1"|"S"|"1998"|"7"|"0"|"Baseboard heating serves Greenhouse only"|"0"||||"0"||"1"|"S"|"1998"|"7"|"0"||"0"||||"0"||"0"||||"8000"|"To add addressable smoke detection system Currently no existing system"|"0"||||"0"||"1"|"S"|"1998"|"5"|"10000"|"Upgrade coverage at various areas "|"0"||||"0"||"0"|"0"|"35000"|"limited accessibility at this facility"|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"limited use sugar facility and greenhouse"|"1"||"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"184000"|"S"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 3:37:52 PM| 629|"Cobleskill-Richmondville CSD"|"54110206"|"Bus Garage/Industrial Arts"|"0017"|"10/01/2010"|"319 Main St "|"RICHMONDVILLE "|" 12149"|"ANNUAL"|"01/01/2011"|"1955"|"6200"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Equipment service, storage, maintenance office"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"1"|"1000"|"0"|"0"|"E"|"2009"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"10"|"0"||"1"|"S"|"2009"|"20"|"0"|"See Radez Elementary BCS"|"0"||||"0"||"0"||||"0"|"See Radez Elementary BCS"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"|"See Radez Elementary BCS"|"0"|||||"0"|"See Radez Elementary BCS"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1955"|"20"|"0"||"1"|"S"|"1955"|"20"|"0"||"1"|"S"|"1986"|"15"|"0"||"1"|"S"|"1986"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1986"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"10"|"0"||"1"|"U"|"1955"|"2"|"15000"|"Poor lighting levels in shop areas, partially replaced. Lighting upgrades recommended in for incandescent and T12 fluorescent fixtures."|"1"|"1"|"E"|"2009"|"20"|"0"|"Radez building phone system extended 2009"|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1955"|"10"|"0"|"Concrete floor in shop are to be resurfaced, painted concrete in office and storage area"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"1"|"S"|"1955"|"1"|"10000"|"replace concrete at overhead door sills -10,000, concrete in shop areas"|"MASONRY"|"0"|"1"||"1"|"0"|"0"|"0"|"1"||"S"|"1986"|"2"|"23000"|"Paint gable ends, soffits - 8,000. Masonry deterioration between overhead doors - 5,000. Masonry deterioration at window sills - 2,000, repointing - 8,000."|"1"|"MASONRY"|"S"|"1955"|"10"|"5000"|"Re-pointing due to age"|"0"|||||"0"||"S"|"S"|"0"|"0"|"1955"|"5"|"2000"|"Exterior HM passage doors to be replaced. Overhead doors starting to rust - 10 years."|"1"|"S"|"1986"|"5"|"500"|"concrete repair at check wall, railing required."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"NA"|"1955"|"5"|"40000"|"Some non-operating although not required for this use. ACM abatment required."|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Shingle edge curl"|"U"|"1986"|"5"|"80000"|"Fascia, soffit repair and paint. Replace 1 roof leader."|"0"|||||"0"||"1"|"COPPER"|"S"|"1986"|"20"|"0"||"1"|"GALVANIZED"|"S"|"1955"|"10"|"0"||"1"|"OIL"|"S"|"1989"|"5"|"5000"||"1"|"U"|"1955"|"2"|"3000"||"0"||"1"|"BOILERWATE"||"U"|"1986"|"0"|"30000"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1986"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"2009"|"1"|"0"|"Generator relocated from Shelter 2003, vintage 1969, beyond useful life. Budget on Radez BCS"|"1"|"0"|"11000"|"Create accessible toilet room, door hardware"|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"POOR"|"Lighting poor for maintenance tasks."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"0"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"1"|"AREAWIDE"|"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,LIGHTING"|||"1"||"FAIR"||"223500"|"U"|"0"|"CSArch"|"40 Beaver St Albany, NY 12207"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/28/2010 3:44:52 PM| 631|"Minisink Valley CSD"|"44110104"|"Elementary/Intermediate School"|"0001"|"05/11/2010"|"R 36 PO BOX 217 "|"SLATE HILL "|" 10973"|"ANNUAL"|"03/01/2011"|"1958"|"174,370"|"2"|"16"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"1152"|"K,1,2,3,4,5"|"0"|"1"|"1"|"1152"|"0"|"0"|||"63"|"42,435"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"8,000"|"S"|"1992"|"20"|"0"||"1"|"WELL"|"S"|"1999"|"40"|"0"||"1"|"SITESEPT"|"S"|"2000"|"50"|"0"||"1"|"S"|"1973"|"10"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2010"|"40"|"0"||"1"|"S"|"2009"|"50"|"0"||"1"|"S"|"2009"|"50"|"0"||"1"|"S"|"2009"|"50"|"0"||"1"|"S"|"2009"|"50"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2009"|"50"|"0"||"0"||||"0"||"1"|"S"|"2009"|"60"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2009"|"2"|"180,000"|"Areas not included in 2009 project. Full depth asphalt replacement along south and southwest sides of building (approx. 4,000 SY)."|"1"|"CONCRETE"|"S"|"2009"|"2"|"15,000"|"Areas not included in 2009 project. Replace all concrete door stoops along southwestern perimeter of building (approximately 1,000 SF)."|"1"|"U"|"2007"|"5"|"75,000"|"Play area not included in 2007 project at western corner of building."|"1"|"S"|"2007"|"5"|"162,000"|"N"|"Regrade old septic field area. Regrade corner of existing softball field. Resurface basketball courts along south perimeter of building. New softball field backstop. New fencing at ball field west of building and along Route 6."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"57"|"0"||"1"|"S"|"1967"|"37"|"0"||"1"|"S"|"1967"|"37"|"75,000"|"Replace worn wall safety padding at Gyms 209A and 12B. Provide permanent wall extend to structure between Classrooms 201 and 202. Cost includes separate HVAC systems for both rooms."|"1"|"S"|"2010"|"35"|"400,000"|"Replace worn and loose glued-on tile ceilings at Corridor C21 with new grid system. Replace worn 2x4 grid and tile system at 1967 wing and Faculty 11B. cost includes all required electrical work."|"1"|"S"|"1967"|"10"|"0"||"1"|"S"|"S"|"1967"|"10"|"405,000"|"Replace worn electrically operated folding partitions at Gyms 209A, A127 and 12B. Replace worn smoke doors and hardware at 14 locations in corridors and stairwells."|"1"|"S"|"1967"|"37"|"0"||"1"|"S"|"1967"|"37"|"0"||"1"|"1"|"E"|"2010"|"40"|"0"||"1"|"E"|"2010"|"30"|"0"||"1"|"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1990"|"1"|"18,000"|"Replace worn carpet in instrumental music room. Replace worn carpet in Classrooms 201 and 202."|"1"|"INSTRUCT"|"S"|"1967"|"5"|"1,000,000"|"Existing VAT floor tiles in classrooms are worn and in need of replacement. Replace worn classroom casework, counters and sinks. Cost includes accessible sink/bubbler units."|"1"|"INSTRUCT,COMMON"|"S"|"1967"|"25"|"0"||"1"|"COMMON"|"S"|"1967"|"5"|"311,000"|"Wood flooring at Gymnasium A127 and stage need refinishing. Bleachers at Gymnasiums A127 and 209A are worn and in need of replacement."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"37"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1958"|"5"|"3,000,000"|"Replace existing lead containing sealant at existing exterior slate panels and broken existing exterior slate panels, deteriorated wood siding at courtyards. Replace exterior envelope with CFMF rigid insulation and prefinished metal panel wall system."|"1"|"MASONRY,METAL"|"S"|"2010"|"75"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"30"|"0"||"1"|"S"|"1958"|"5"|"60,000"|"Replace deteriorated exterior steps and masonry retaining walls at upper courtyard and reconstruct to include ramps for accessibility."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"26"|"88,500"|"Replace windows with thermal units to match remainder of units at Vestibule 29A between D and B wings and A wing 1967 addition. Replace deteriorated corrugated translucent wall in Gym 12B with insulated translucent system."|"WOODONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"25"|"0"||"1"|"PLASTIC"|"S"|"2009"|"5"|"15,500"|"Replace 8 cracked/deteriorated 4x6 units skylights at Gym 209A."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1999"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"10"|"0"||"1"|"E"|"2010"|"30"|"4,500"|"Remove plumbing fixtures in locker/shower rooms to enhance usability of space (currently used for other functions). Provide hands free faucets; 2 in kitchen and 1 in Nurse's office."|"0"||"1"|"BOILERWATE"||"E"|"2010"|"25"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"25"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"25"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"10"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"30"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"7,552,350"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/28/2010 4:04:16 PM| 633|"Rockville Centre UFSD"|"28022103"|"William Covert Elementary School"|"0004"|"09/15/2010"|"25 Buckingham Road"|"Rockville Centre"|" 11570"|"ANNUAL"|"04/01/2011"|"1930"|"36968"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"392"|"K,1,2,3,4,5"|"0"|"0"|"0"|"392"|"0"|"0"|||"21"|"16,800"|"ART,AUDITORIUM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1988"|"28"|"1,500"|"Provide cage & signage for overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1930"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1930"|"5"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1930"|"5"|"0"||"1"|"S"|"1988"|"28"|"0"||"0"||||"0"||"1"|"S"|"1930"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"15"|"2,500"|"Replace 75 lf of damaged curbing."|"1"|"CONCRETE"|"S"|"2005"|"15"|"7,500"|"Repair front picket fence, repair cracked sidewalk (50 sf)."|"1"|"S"|"1999"|"9"|"6,500"|"Repair rubber base."|"1"|"S"|"2003"|"13"|"54,000"|"N"|"Repair sinking drain cover, refurbish field, provide 6' chain link fence along N. property line (150 lf)."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"20"|"0"||"1"|"S"|"1997"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"15"|"0"||"1"|"S"|"1938"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"1930"|"26"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"1"|"S"|"1986"|"5"|"135,500"|"Replace PA/intercom system and tie to phone switch, repair clock on tower, provide Smart Boards in remaining CR's (5)."|"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"15"|"0"||"1"|"COMMON"|"S"|"1997"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1938"|"15"|"0"||"SLABGRADE,OTHER"|"Reinforced concrete beam slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"20"|"0"||"1"|"MASONRY"|"S"|"1997"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"||"1"|"S"|"1997"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"20"|"0"||"METONMET,WOODONWOOD"|"BUILTUP,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1930"|"5"|"0"||"1"|"GALVANIZED"|"S"|"1930"|"5"|"0"||"1"|"OIL"|"S"|"1995"|"5"|"0"||"1"|"S"|"1930"|"5"|"1,000"|"Provide emergency eyewash on nurses sink."|"1"|"CV"|"0"|"BOILERSTEA"||"S"|"1980"|"5"|"570,000"|"Replace Weil Mc Lane boilers."|"1"|"S"|"1980"|"5"|"0"||"1"|"S"|"1980"|"5"|"0"||"1"|"S"|"1930"|"5"|"0"|"ProvFAIrms 21A,staff lounge,24B,mediation room,SWoffice,readingrm(2,nurse,gym 11A,MrsCohen&portCRs,cleangrlsBRexhreg,providebirdscreenatticexh&cleanpigeondebris,rprGRsys,mechexhforBRs(4)birdscreens2 atticexhhoodsuncoverUVFAIupgradeexh2BRs."|"1"|"S"|"1986"|"26"|"6,500"|"Provide heater in new wing hallway."|"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1980"|"5"|"120,000"|"Replace proprietary Simplex system."|"1"|"S"|"1980"|"5"|"0"||"0"||||"0"||"1"|"S"|"1980"|"5"|"650"|"Repair/replace emergency light fixture."|"0"||||"0"||"1"|"0"|"625,000"|"No elevator. No lift to auditorium. District designated facilities."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"0"|"0"|"FAIR"||"1,815,300"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/28/2010 4:07:54 PM| 634|"North Colonie CSD"|"01062306"|"Shaker Jr. High"|"0009"|"07/19/2010"|"475 Watervliet Shaker Road"|"Latham"|"12110"|"ANNUAL"|"01/01/2011"|"1962"|"160784"|"2"|"5"|"2"|"DISTRICT"|"INSTRUCT"||"928"|"7,8"|"0"|"1"|"1"|"928"|"0"|"0"|||"53"|"45400"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"10000"|"0"|"0"|"S"|"2005"|"10"|"0"|"New pumps installed 2005, tank 1962."|"1"|"MUN_UTILIT"|"S"|"2002"|"10"|"0"|"RPZ on both services."|"1"|"MUN_UTILIT"|"S"|"2002"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"10"|"15000"|"Conduit from building to concessions needed."|"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"MUNI"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"5"|"400000"|"Main parking sealed and striped 2010. Existing asphalt breaking up, consider replacing."|"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"15"|"0"|"Pave walkway from library door needed."|"0"||||"0"||"1"|"S"|"1999"|"20"|"0"|"N"|"Natural sod."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"|"1962 corridor walls may not have fire rating."|"1"|"S"|"2004"|"20"|"50000"|"Walls are original to vintage 1962. Horizontal crack at boys locker room. Replace gym partition with curtain."|"1"|"S"|"2004"|"15"|"0"|"1998 at corridors."|"1"|"S"|"1962"|"10"|"0"|"Approximately 1500 total corridor."|"1"|"S"|"S"|"2004"|"5"|"24000"|"Gym doors are in poor condition but functional. 1962 corridor doors are non-rated."|"1"|"S"|"1962"|"20"|"0"||"1"|"S"|"1962"|"15"|"200000"|"Locater signs needed,replace original."|"1"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"45000"|"Lights throught replaced 1998. 2004 addition, gym MTL halide, could be replaced with T5s."|"1"|"1"|"S"|"2002"|"15"|"10000"|"Improve PA for gyms."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"5"|"40000"|"Carpet in library hallway and auditorium is bubbled."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"5"|"500000"|"1962 classrooms ae mostly VAT and worn."|"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"15"|"0"|"Wood at gym, technology and weight room-stage."|"SLABGRADE,CONCRMETAL,OTHER"|"concrete-tectum"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"U"|"2009"|"5"|"25000"|"Brick repair and repointing completed in 2009. Panel complete 1998. Reviewed envelope leak at science rooms - frozen pipes."|"1"|"METAL"|"S"|"2005"|"15"|"0"|"Metal flue replaced with boilers."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"15"|"0"|"FRP and aluminum throughout."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"|"Main building roof replaced 2002."|"1"|"PLASTIC"|"S"|"2004"|"15"|"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON"|"S"|"2002"|"15"|"60000"|"ACM fittings at toilet chases."|"1"|"NAT_GAS"|"S"|"2009"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"|"ADA fixtures at B wing and E art wing."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"|"Library cental AC, classroom window AC"|"1"|"U"|"2010"|"10"|"1050000"|"1962 gym AHU replaced 2010. Cafeteria, kitchen, auditorium AHU and classroom UVs need replacing."|"1"|"S"|"2004"|"10"|"0"|"Classroom piping insulated 2010."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2010"|"10"|"0"|"DDC additional sensors installed 2010, pneumatic controls still present."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"|"Additional smoke detectors required at some rooms."|"1"|"S"|"2004"|"2004"|"0"||"1"|"S"|"2004"|"10"|"0"|"Coverage of exit lights may not satisfy current code."|"1"|"S"|"2010"|"20"|"0"||"1"|"1"|"5000"|"Stage is accessible by use of districts portable lift. Install auto door opener."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"0"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,HVAC,FRIDGE,LIGHTING"|"FULL"||"1"||"GOOD"||"2649000"|"U"|"1"|"CSArch"|"40 Beaver St., Albany, NY 12207"|"518 463-8068"|"pnickerson@csarchpc.com"|"Paul Nickerson"|"029429"|"I ACCEPT"|12/28/2010 4:12:21 PM| 635|"Minisink Valley CSD"|"44110104"|"Otisville Elementary School"|"0004"|"05/11/2010"|"2525 Mount Hope Avenue"|"OTISVILLE "|" 10963-2333"|"ANNUAL"|"03/01/2011"|"2008"|"125296"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"738"|"K,1,2,3,4,5"|"0"|"0"|"0"|"738"|"0"|"0"|||"38"|"29260"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"2"|"600"|"1"|"12,000"|"S"|"2008"|"30"|"0"||"1"|"MUN_UTILIT"|"E"|"2008"|"50"|"0"||"1"|"SITESEPT"|"S"|"2008"|"30"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2008"|"38"|"0"||"1"|"E"|"2008"|"50"|"0"||"1"|"E"|"2008"|"50"|"0"||"1"|"E"|"2008"|"50"|"0"||"1"|"E"|"2008"|"50"|"0"||"1"|"SURFACEH2O"||"0"|"E"|"2008"|"50"|"0"||"0"||||"0"||"1"|"E"|"2008"|"50"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2008"|"30"|"0"||"1"|"CONCRETE"|"E"|"2008"|"30"|"0"||"1"|"E"|"2008"|"50"|"0"||"1"|"S"|"2008"|"50"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2008"|"100"|"0"||"1"|"E"|"2008"|"80"|"0"||"1"|"E"|"2008"|"80"|"0"||"1"|"E"|"2008"|"25"|"0"||"1"|"E"|"2008"|"40"|"0"||"1"|"E"|"E"|"2008"|"35"|"0"||"1"|"E"|"2008"|"80"|"0"||"1"|"E"|"2008"|"80"|"0"||"1"|"1"|"E"|"2008"|"38"|"0"||"1"|"E"|"2008"|"28"|"0"||"1"|"1"|"E"|"2008"|"18"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"E"|"2008"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2008"|"20"|"0"||"1"|"COMMON"|"E"|"2008"|"20"|"0"||"1"|"COMMON"|"E"|"2008"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2008"|"80"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"75"|"0"||"1"|"METAL"|"E"|"2008"|"75"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2008"|"35"|"0"||"1"|"E"|"2008"|"30"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2008"|"35"|"0"||"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"25"|"0"||"1"|"PLASTIC"|"E"|"2008"|"25"|"0"||"1"|"COPPER"|"E"|"2008"|"78"|"0"||"1"|"IRON,COPPER"|"E"|"2008"|"78"|"0"||"1"|"OIL"|"E"|"2008"|"13"|"0"||"1"|"E"|"2008"|"28"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2008"|"23"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"23"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"23"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"60"|"0"||"1"|"E"|"2008"|"18"|"0"||"1"|"E"|"2008"|"2008"|"0"||"1"|"E"|"2008"|"13"|"0"||"1"|"E"|"2008"|"28"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT"|"GOOD"||"0"|"0"|"0"|"0"|"0"|"INACTIVE"|"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"|"0"|"0"|"1"|"GOOD"||"0"|"E"|"1"|"Tetra Rech Architects and Engineers"|"10 Brown Road"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/28/2010 4:32:50 PM| 637|"Cobleskill-Richmondville CSD"|"54110206"|"William H. Golding"|"0003"|"10/21/2010"|"193 Golding Drive "|"COBLESKILL "|" 12043"|"ANNUAL"|"01/01/2011"|"1932"|"125000"|"3"|"5"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"513"|"6,7,8"|"0"|"1"|"1"|"513"|"0"|"0"|||"50"|"48890"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"2"|"3500"|"0"|"0"|"E"|"2009"|"20"|"0"|"Diesel generator tanks"|"1"|"MUN_UTILIT"|"S"|"1952"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1952"|"10"|"0"|"Recommend video of existing piping due to annual blockage"|"1"|"S"|"1964"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2008"|"5"|"10000"|"Main switch trips upon transfer from standby generator to normal utility. Recommend contract meter logging to diagnose and an over-current protective device coordination study performed by an electrical engineer."|"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"0"|"S"|"2003"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"1986"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"|"Plaster damage at window jambs"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"S"|"2003"|"5"|"11000"|"Knob locksets at end of useful life, non ADA compliant, approx 35"|"1"|"S"|"1986"|"3"|"95000"|"Stone stair tread, landing nosing worn and repair material worn off"|"1"|"S"|"1999"|"20"|"0"||"1"|"1"|"S"|"2008"|"20"|"0"|"Recommend local TVSS protection for computers - 1,000"|"1"|"S"|"2003"|"5"|"258000"|"Gym lighting at end of useful life - 23,000. Upgrade stage and aud lighting - 230,000, Basement safety lighting - 5,000."|"1"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2003"|"15"|"0"|"Library carpet"|"1"|"INSTRUCT,COMMON"|"S"|"2009"|"3"|"90000"|"VCT ppor in 3 classrooms - requires abatement and self leveling."|"1"|"INSTRUCT,COMMON"|"S"|"2003"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1969"|"5"|"85000"|"Gym and technology classrooms. Gym near end of expected life."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"S"|"2003"|"2"|"15000"|"Window sealants replacement, plaster damage at jambs, stone sill deterioration at south entry."|"1"|"MASONRY"|"S"|"1932"|"5"|"25000"|"Previously abandoned chimney to be removed - 20,000. Water heater chimney to be re-pointed - 5,000."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"20"|"0"||"1"|"S"|"2003"|"5"|"45000"|"Replace auditorium exit steps due to stone deteriorationa and salt damage."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"15"|"0"|"Windows replaced 1989, addition 2003. Some egress windows blocked by roller shades."|"METONMET,CONMETMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"S"|"2009"|"2"|"120000"|"Areas of delamination and top coat deterioration. Re-coat spray foam installed 1998 and 2000 to extend warranty."|"1"|"GLASS"|"S"|"2000"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"IRON"|"S"|"2004"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1992"|"2"|"48000"|"Replace water heater and storage tanks in former boiler room."|"1"|"S"|"2004"|"15"|"0"|"Public toilet rooms renovated 2000"|"0"||"1"|"GEOTHERMAL"||"S"|"2004"|"15"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"|"Ground coupled heat pumps."|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2003"|"20"|"0"|"EST addressable system. Basement and library require notification devices - 4,000."|"1"|"S"|"2003"|"20"|"0"|"Basement and library require notification devices - 4,000"|"1"|"S"|"2004"|"2004"|"0"|"Kitchen hood, building un-sprinklered"|"1"|"S"|"2003"|"2"|"1500"|"All lighting on generator. Replace exit signs in gym due to age."|"1"|"E"|"2009"|"20"|"0"||"1"|"1"||"Door hardware - replace knob locksets with lever sets."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"Gym - fair, Auditorium - poor"|"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"1"|"AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"||"798500"|"S"|"0"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/28/2010 4:37:47 PM| 638|"Warsaw CSD"|"67150104"|"MS/HS"|"0007"|"06/25/2010"|"W COURT ST "|"WARSAW "|" 14569"|"ANNUAL"|"08/01/2011"|"1960"|"163,328"|"2"|"10"|"0"|"DISTRICT"|"INSTRUCT"||"548"|"6,7,8,9,10,11,12"|"0"|"1"|"0"|"548"|"0"|"0"|||"24"|"19,119"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"30"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"MUNI"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT,GRAVEL"|"S"|"2004"|"4"|"43,750"|"Seal front lot; add asphalt to service entry at Boiler Room."|"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"4"|"48,750"|"Athletic areas; landscaping."|"0"||||"0"||"1"|"S"|"2004"|"15"|"312,500"|"Y"|"Resurface track."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"35"|"0"||"1"|"S"|"2002"|"35"|"15,000"|"Replace interior windows in I.A. Shop."|"1"|"S"|"2002"|"10"|"30,000"|"Add Cafeteria acoustical treatment."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"S"|"2002"|"20"|"18,750"||"1"|"S"|"2002"|"15"|"60,000"|"Replace fixtures in fifteen rooms with T-8."|"1"|"1"|"S"|"2003"|"5"|"146,250"|"Replace telephones with VOIP system; add Auditorium speakers; add LGI speakers and clock; add Dark Room clock."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"7,500"|"Replace carpets in five rooms in 1992 addition."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"60,000"|"Replace Cafeteria floor."|"1"|"COMMON"|"S"|"2002"|"15"|"0"||"1"|"COMMON"|"S"|"2002"|"15"|"10,000"|"Repair Auditorium steps."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"1"|"METAL"|"S"|"2001"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"0"||"1"|"S"|"2002"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM,OTHER"|"S"|"Y"|"2002"|"15"|"165,000"|"Replace miscellaneous glass block; replace 1992 windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"4"|"1,362,500"|"Replace 1992 section of roof."|"1"|"GLASS"|"S"|"2002"|"4"|"0"|"Included in number 68U."|"1"|"COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"6,250"|"Install induced draft fan."|"1"|"S"|"2002"|"10"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"20"|"0"||"1"|"S"|"1960"|"10"|"0"||"1"|"S"|"2002"|"15"|"18,750"|"Add cooling to Server Room 207A."|"1"|"U"|"2002"|"10"|"185,000"|"Revise Library Office heat; replace dust collection system in I.A. Shops; add ventilation in Team Lockers."|"1"|"S"|"2002"|"10"|"22,500"|"Add DDC controls with cooler/freezer; install cooling isolatin valves."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"3,750"|"Add fire alarm to Room 239A."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"|"See #47."|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Shop dust collection inadequate."|"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"1"|"0"||"FULL"|"0"|"1"||"GOOD"||"2,501,250"|"U"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"Robert J. Nordin, AIA, LEED AP"|"028213"|"I ACCEPT"|12/28/2010 4:41:36 PM| 639|"West Canada Valley CSD"|"21030204"|"Bus Garage+Addition "|"5005"|"10/11/2010"|"5447 STATE RT 28 "|"NEWPORT "|" 13416"|"ANNUAL"|"11/01/2010"|"1963"|"8900"|"1"|"4"|"0"|"DISTRICT"|"OTHER"|"Bus Maintenance and Storage"|"0"|||"0"|"0"||||||"0"|"0"|||"1"|"0"|"0"|"1"|"1000"|"S"|"1963"|"15"|"0"||"1"|"WELL"|"E"|"2000"|"15"|"0"|"Water fed from Main campus well system"|"1"|"SITESEPT"|"S"|"1963"|"15"|"0"|"New cleanouts installed at septic tank and sanitary tie-in of new employee toilet rooms in2008,"|"1"|"E"|"2009"|"20"|"0"|"100 gal L.P. tank, new underground gas main in 2009"|"1"|"UTIL"|"BELOW"|"E"|"1988"|"15"|"0"||"1"|"S"|"2008"|"25"|"0"|"Roof drains separated from floor drains per DEC req's in 2008. Floor drains re-piped into 3000 gal. holding tank at front of garage."|"0"||||"0"||"1"|"S"|"1999"|"10"|"0"|"Roof drains connect to K-12 storm system."|"0"||||"0"||"1"|"SURFACEH2O"|"connected to K-12 storm system outfall"|"1"|"S"|"1999"|"25"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT"|"S"|"1988"|"5"|"0"|"Pavement area shared with K-12 school"|"0"|||||"0"||"0"||||"0"||"0"||||" "|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"30"|"0"|"Original foundation conc. footings with CMU, New 2008 addition foundation concrete footins and wall. "|"1"|"S"|"1988"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"|" "|"1"|"E"|"2008"|"10"|"0"|"Acoustic Ceiling installed in driver's room 2008"|"0"||||"0"||"1"|"S"|"E"|"2008"|"10"|"0"|"Interior doors added in reconstruction work 2008"|"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2008"|"30"|"0"|"New panel, circuits/wiring as part of 2008 Addition/reconstruction work."|"1"|"S"|"2008"|"5"|"10000"|"New lighting in reconstruction and addition areas, existing lighting remains in bus storage. Upgrade to efficient lighting planned."|"1"|"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2008"|"15"|"0"||"1"|"COMMON"|"E"|"2008"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2008"|"30"|"0"|"Maintenance bay area concrete floor partially replaced for new lift."|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"25"|"0"|"Additions in 1988 and 2008"|"1"|"METAL"|"S"|"2000"|"5"|"0"|"New boiler/flue replacement planned for 2011"|"0"|||||"0"||"S"|"E"|"0"|"1"|"2008"|"5"|"48000"|"Maintence bay OH doors replaced in 2008. New HM doors added in renovation work in 2008. New OH doors planned for 2013"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2008"|"15"|"0"|"Window reconstruction in 2008."|"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"10"|"0"|"New roof and tie-in to existing at maintenance addition area."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"E"|"2008"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"E"|"2008"|"25"|"0"|"New employee toilets added 2008"|"1"|"ELECTRIC"|"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"||"0"||"1"|"BOILERWATE"||"U"|"1999"|"5"|"10000"|"Boiler replacement planned for 2011"|"0"|"S"|"1999"|"5"|"0"||"0"||||"0"||"1"|"E"|"2008"|"10"|"0"||"1"|"E"|"2008"|"25"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"E"|"2008"|"10"|"0"||"0"||||"0"|"Annunciation only"|"0"||||"0"||"0"||||"0"||"0"|"E"|"2008"|"15"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"160000"|"U"|"0"|"Glynn Spillane Griffing Architects PC"|"187 Wolf Road, Albany NY 12205"|"518 463 1114"|"rmichel@gsgarchitects.com"|"Richard Michel"|"022253"|"I ACCEPT"|12/28/2010 4:43:40 PM| 640|"Plainview-Old Bethpage CSD"|"28050406"|"Fern Place School"|"0020"|"09/28/2010"|"FERN PLACE "|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1949"|"47043"|"2"|"1"|"0"|"LSD_NDE"|"OTHER_ORG"||"150"|"OTHER"|"0"|"0"|"1"|"150"|"150"|"0"|||"17"|"13,600"|"ADMIN,COMPROOM,GYM,HLTHSUITE,MULTIPURPO"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"35"|"1,500"|"Provide cage for overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1955"|"5"|"96,000"|"Provide additional site fire hydrant."|"1"|"MUN_UTILIT"|"S"|"1995"|"35"|"0"||"1"|"S"|"2000"|"40"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1955"|"5"|"0"||"1"|"S"|"1949"|"10"|"0"||"0"||||"0"||"1"|"S"|"1949"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1949"|"10"|"18,000"|"Allowance to supplement parking lot drainage in conjunction with item #52."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1949"|"0"|"500,000"|"Repave all parking lots and replace all curbs."|"1"|"CONCRETE,ASPHALT"|"U"|"1949"|"0"|"97,000"|"Replace all sidewalks except north side-crackfill and seal."|"1"|"S"|"1949"|"10"|"0"||"1"|"S"|"1949"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1949"|"15"|"0"||"1"|"S"|"1949"|"15"|"0"||"1"|"S"|"1949"|"15"|"30,000"|"Replace all toilet room partitions."|"1"|"S"|"1949"|"10"|"455,000"|"Replace ceilings entire building except main offices and hard ceilings. Repalce ceilings & lighting all corridors."|"0"||||"0"||"1"|"S"|"U"|"1949"|"5"|"35,000"|"Replace all locksets on corridor doors to lever-type."|"1"|"S"|"1949"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1955"|"5"|"190,500"|"Provide additional CR receptacles, replace fuse type electric panels & provide lightning protection, provide additional circuits in speech corner, provide 2nd GFI in lunch room."|"1"|"S"|"2004"|"14"|"7,000"|"Repair/replace 4 exterior lights & repalce missing fixture lenses."|"1"|"1"|"S"|"1955"|"5"|"402,500"|"Provide clock & security systems & provide data/electric in CR's, add camera by back area."|"0"||||"0"||"1"|"COMMON"|"S"|"1949"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1949"|"10"|"105,000"|"Replace cafeteria VCT. Repalce 1st & 2nd floor corridor VCT over/VAT, and install missing floor E.J. cover."|"1"|"COMMON"|"S"|"1949"|"10"|"0"||"1"|"COMMON"|"S"|"1949"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1949"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"185,000"|"Paintdr&siding@formerO.H.dr.Pntext clmns,rprcrackedconcpnls,replcustodarea lintel,gymdrlintel,cutin(8)newMCJs Tuckpnt400sf@gym&12x24WsideformerLR. ReconstSEcornerofaudit&repldoorlintel. Reconstmasonry@Send2nd flr overroof&other areas."|"1"|"MASONRY"|"S"|"1949"|"10"|"40,000"|"Re-build upper 4' of chimney & repalce concrete cap, tuckpoint remainder. Add stainless steel cap."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1949"|"0"|"238,000"|"Replace all exterior doors & frames, including glazed assemblies."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2000"|"15"|"0"||"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"15"|"20,000"|"Add rood drain over custodial area."|"0"|||||"0"||"1"|"COPPER"|"S"|"1955"|"5"|"18,000"|"Replace 5 hose faucets, reset gas pipe on roof, provide emergency shower."|"1"|"IRON"|"S"|"1955"|"5"|"26,000"|"Clear and provide vent caps on roof and provide duplex sump pump."|"1"|"NAT_GAS"|"S"|"1995"|"5"|"27,000"|"Provide Summer bypass piping, replace DHWH."|"1"|"S"|"1955"|"10"|"59,000"|"Replace (6) flushometers, (4) slop sink faucets, (10) fixtures with hairline cracking & remove all drinking fountains from sinks, provide auto sensing faucets, provide emergency eyewash & restore all hall drinking fountains."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2002"|"32"|"3,000"|"Replace burned out burner indicating lights."|"1"|"S"|"2002"|"32"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1955"|"5"|"341,000"|"Refurbish cafetorium and gym units. Provide FAI in subdivided rooms (10), reopen 1 UV FAI, refurbish rooftop exhaust fans (12), reconnect all UV dampers."|"1"|"S"|"1955"|"5"|"110,000"|"Refurbish steam traps, eliminate system banging, resecure girls room baseboard, provide splice plates and end caps for cafeteria baseboard."|"1"|"S"|"1955"|"5"|"0"||"1"|"S"|"2000"|"10"|"130,000"|"Provide energy management system and refurbish controls."|"1"|"S"|"1995"|"10"|"80,000"|"Update FA system to ADA."|"1"|"S"|"1995"|"10"|"45,000"|"Provide additional smoke detectors in halls and cafeteria."|"0"||||"0"||"1"|"S"|"1990"|"5"|"16,750"|"Provide additional emergency lighting in corridors & change all exit signs to LED, repair/replace emergency lighting #22, provide additional exit signs in gym."|"0"||||"0"||"0"|"0"|"650,000"|"Provide elevator, convert (2) toilets each floor & nurses toilet for HCA."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|||"0"|"0"||||"1"||"FAIR"|"ACDS is outgrowing school building"|"3,846,250"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/28/2010 4:55:10 PM| 641|"East Syracuse-Minoa CSD"|"42040106"|"Minoa Elementary"|"0020"|"08/03/2010"|"MAIN ST "|"MINOA "|" 13116"|"ANNUAL"|"10/01/2010"|"1964"|"48040"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"353"|"K,1,2,3,4,5"|"0"|"1"|"0"|"353"|"0"|"0"|||"15"|"12000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"15"|" "||"1"|"MUN_UTILIT"|"S"|"1964"|"15"|"0"||"1"|"S"|"1964"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"30"|"0"|"Upgraded site lighting w/ "Safe + Sound" project."|"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1964"|"10"|"0"||"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2006"|"20"|"0"|"Reconstructed parking/bus loop w/ "Safe + Sound" Project."|"1"|"CONCRETE,ASPHALT"|"E"|"2006"|"20"|"0"|"Upgraded w/ "Safe + Sound" project"|"1"|"S"|"1994"|"15"|"0"||"1"|"S"|"1964"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"50"|"0"||"1"|"S"|"1964"|"50"|"0"||"1"|"S"|"2002"|"50"|"10,000"|"Recommend replacing chase walls @ toilet rms @ classrooms."|"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2009"|"10"|"0"|"Door hardware upgraded w/ EXCEL funds, door original to bldg."|"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"1964"|"5"|"193,000"|"Recommend replacing main switchboard; add outlets to classrooms"|"1"|"E"|"2009"|"30"|"0"|"Upgraded w/ Energy Performance Contract."|"1"|"1"|"U"|"2009"|"5"|"79,000"|"Recommend updating PA & Clock system; repair clock synchronization issue"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"15"|"0"|"Library"|"1"|"INSTRUCT"|"U"|"1964"|"5"|"218,000"|"Recommend abating VAT at various classrooms, cafeteria, stage"|"1"|"COMMON"|"S"|"1964"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1964"|"25"|"0"|"Ongoing maintenance (sealing)"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"50"|"0"|"2009 exterior asphalt pads @ UV locations w/ EXCEL funding."|"MASONRY,STEEL"|"1"|"0"||"1"|"1"|"0"|"0"|"0"||"U"|"2009"|"5"|"15,000"|"Repair crack & add control joints; patch/paint exterior soffits"|"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"30"|"0"|"Upgraded w/ EXCEL funds."|"1"|"S"|"1964"|"40"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"|"Upgraded w/ Energy Performance Contract. "|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Replaced w/ "Safe + Sound" project. "|"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1964"|"10"|"0"||"1"|"IRON"|"U"|"1964"|"5"|"700,000"|"Recommend replacing under-slab sanitary @ classroom (drainage issue)"|"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"|"1999 - 180 degree water to dishwasher; 2005 supplies school"|"1"|"U"|"2009"|"5"|"306,000"|"Recommend replacing all original fixtures"|"0"||"1"|"BOILERWATE"||"U"|"1964"|"5"|"569,000"|"Recommend replacing boilers & associated equipment (reaching end of useful life)"|"1"|"S"|"1964"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"|"Media Center and interior classrooms have A/C"|"1"|"U"|"1964"|"5"|"945,000"|"Recommend replacing UV's, Gym H&V; exhaust fans (reaching end of useful life)"|"1"|"U"|"1964"|"5"|"53,000"|"Recommend replacing misc piping w/ other HVAC upgrades"|"1"|"U"|"1964"|"5"|"32,000"|"Recommend replacing original control dampers w/ other HVAC upgrades"|"1"|"U"|"2009"|"5"|"133,000"|"Unit controls to be replaced w/ other HVAC upgrades"|"1"|"U"|"2000"|"5"|"131,000"|"Recommend replacing Simplex 4002 w/ point addressable system; add classroom stobes"|"1"|"U"|"2000"|"5"|"35,000"|"Recommend replacing w/ point addressable devices"|"0"||||"0"||"1"|"U"|"2009"|"5"|"9,000"|"Recommend adding battery packs in corridors; existing exits are LED"|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"||"FAIR"||"3,428,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"3156826180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/28/2010 5:01:32 PM| 642|"Commack USFD"|"58041003"|"SMITHS LANE ELEMENTARY SCHOOL"|"0011"|"02/19/2010"|"9 SMITHS LANE "|"SMITHTOWN "|" 11725"|"ANNUAL"|"05/01/2011"|"1957"|"46000"|"1"|"1"|"5"|"LSD_NDE"|"INSTRUCT,OTHER"||"69"|"UNGRD"|"0"|"0"|"0"|"69"|"0"|"0"|"GYM,OTHER"|"Kitchen was dismantled for instr. space use"|"14"|"12073"|"ADMIN,AUDITORIUM,CAFE,HLTHSUITE,SPECED,OTHER"|"Audit for treatment"|"1"|"0"|"0"|"1"|"10000"|"S"|"2009"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"10"|"0"||"1"|"SITESEPT"|"S"|"1957"|"15"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"10"|"0"||"1"|"S"|"1957"|"15"|"0"||"0"||||"0"||"1"|"S"|"1957"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"1"|"75000"|"Replace pavement on East side of parking area."|"1"|"CONCRETE,ASPHALT"|"U"|"2008"|"1"|"10000"|"Replace concrete curb at front sidewalk."|"0"||||"0"||"1"|"S"|"1957"|"15"|"0"|"N"|"Playfield is used by Commack UFSD only."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"25"|"0"||"1"|"S"|"1957"|"25"|"0"||"1"|"S"|"1957"|"25"|"0"||"1"|"U"|"1957"|"1"|"255000"|"Replaced concealed spline system with new grid and drop tiles for easy access to roof structure above."|"0"||||"0"||"1"|"U"|"U"|"1957"|"1"|"15000"|"Six doors need to be replaced."|"1"|"S"|"1957"|"5"|"0"|"Stair to Boiler Room only."|"0"||||"0"||"1"|"1"|"S"|"2007"|"15"|"0"||"1"|"U"|"1957"|"1"|"110000"|"Replace lighting fixtures."|"1"|"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1957"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"1957"|"1"|"120000"|"Replace tile flooring."|"1"|"COMMON"|"S"|"1957"|"10"|"0"||"0"|||||"0"||"SLABGRADE,OTHER"|"Cast-in-place reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1957"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1957"|"15"|"0"||"1"|"MASONRY"|"U"|"1957"|"1"|"20000"|"Chimney needs repointing."|"0"|||||"0"||"S"|"U"|"0"|"1"|"1957"|"1"|"6000"|"Replace existing sliding entrance doors."|"1"|"U"|"1957"|"1"|"60,000"|"Replace ramp at East side of 100 wing."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1957"|"1"|"350000"|"Replace with energy efficient windows."|"OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"1"|"1"||"U"|"1980"|"1"|"400000"|"Roofing needs replacement."|"0"|||||"0"||"1"|"COPPER"|"S"|"1957"|"5"|"0"||"1"|"IRON"|"S"|"1957"|"5"|"0"||"1"|"OIL"|"U"|"1957"|"1"|"3000"|"Provide new hot water heater as required. There is no hot water in C.R. 210 and Women Toilet in Wing 200."|"1"|"U"|"1957"|"1"|"30000"|"Replace faucets throughout."|"0"||"1"|"BOILERWATE"||"U"|"2002"|"1"|"15000"|"Heating is not constant in some areas. Valves need to be replaced or repaired."|"1"|"S"|"2002"|"41"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"U"|"1986"|"1"|"50000"|"Repair or replace exhaust fans."|"0"|"U"|"1957"|"1"|"15000"|"Replace circulator No. 2."|"0"||||"0"||"1"|"U"|"1957"|"1"|"50000"|"Replace aging pneumatic control system."|"1"|"S"|"1957"|"5"|"0"||"1"|"S"|"1957"|"5"|"0"||"0"||||"0"||"1"|"S"|"1957"|"5"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"POOR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 1,609,000"|"U"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/28/2010 5:15:40 PM| 644|"Cheektowaga-Maryvale UFSD"|"14070203"|"Maryvale Stadium Building"|"0008"|"10/12/2010"|"1050 Maryvale Drive"|"Cheektowaga"|"14225"|"ANNUAL"|"08/01/2011"|"1954"|"3830"|"1"|"7"|"0"|"DISTRICT"|"OTHER"|"Restrooms, athletic"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"OTHER"|"Outdoor recreation."|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"40"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"44"|"0"|"Partial repairs made in 1996. Lateral was installed in 1954 and expected remaining life is based on that year."|"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2009"|"40"|"0"|"Cost to install vandal proof wall packs (2) per current code requirements."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"CONCRETE"|"S"|"1995"|"4"|"29830"|"Cost to replace 400 SF of building sidewalks."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"40"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2008"|"3"|"35229"|"Original panelboards should be replaced. Original branch circuits should be replaced."|"1"|"S"|"2008"|"3"|"11311"|"Some storage areas have no lighting."|"1"|"0"|"S"|"2008"|"5"|"3098"|"We recommend providing a telephone and PA loudspeaker in the pressbox however it is not required. Stadium exterior speakers are provided for all call paging. We also recommend providing an intrusion detection sensor but it is not required either."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1954"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"40"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2009"|"40"|"0"|"Cost for minor repointing of brick veneer (200 FT)."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"20"|"0"||"1"|"S"|"2009"|"40"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2009"|"20"|"0"|"Press box is new on top of bleachers."|"OTHER"|"FORMMETAL,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2008"|"30"|"0"||"1"|"IRON,COPPER"|"S"|"1990"|"45"|"0"||"1"|"ELECTRIC"|"S"|"1989"|"4"|"16500"|"Water heater is at end of useful life - should be replaced."|"1"|"E"|"2009"|"30"|"0"||"0"||"1"|"OTHER"||"E"|"2009"|"15"|"0"|"Electric Fin Tube heater in Press Box. Electric Unit Heater in Concession area."|"1"|"E"|"2009"|"40"|"0"|"Electric source to new stadium Press Box and Concessions."|"0"||||"0"||"1"|"E"|"2009"|"15"|"0"|"Unit heater and fin tube - natural ventilation."|"0"||||"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"|"Local control only."|"1"|"S"|"2009"|"15"|"0"|"Strobe/Horn & pull stations should be provided in pressbox."|"1"|"S"|"2008"|"15"|"0"|"Smoke detector should be provided in pressbox."|"0"||||"0"||"1"|"U"|"2008"|"5"|"1371"|"Non-functioning fixtures should be replaced; exit sign should be added at exit door in concessions corridor."|"0"||||"0"||"1"|"0"|"0"||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"1"||"FAIR"||"97339"|"U"|"1"|"Cannon Design"|"2170 Whitehaven Road, Grand Island, NY, 14072"|"7167736800"|"jcassata@cannondesign.com"|"Joe Cassata"|"028762"|"I ACCEPT"|12/29/2010 8:30:16 AM| 649|"Plainview-Old Bethpage CSD"|"28050406"|"H.B. Mattlin Middle School"|"0014"|"09/28/2010"|"WASHINGTON AVE "|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1963"|"207584"|"2"|"12"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"785"|"5,6,7,8"|"0"|"1"|"0"|"785"|"0"|"0"|||"80"|"64,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1990"|"30"|"10,000"|"Provide new stick line/manhole."|"1"|"MUN_UTILIT"|"S"|"1963"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1963"|"5"|"0"||"1"|"S"|"1963"|"10"|"7,500"|"Re-route A-wing downspout underground and away from gas service."|"1"|"S"|"1963"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2010"|"10"|"10,000"|"Add drywell by dumpsters."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"10"|"365,000"|"Replace 100' curb area&400' curb at bus loop&150' allowance add'l curb at various locations. Crackfill&seal parking all around bldg. Minor repair to lot by chimney. Add parking in bus loop."|"1"|"CONCRETE,ASPHALT"|"S"|"1963"|"5"|"235,000"|"Replace courtyard concrete and add drainage. Replace various areas concrete sidewalk, plaza and mow-strips in many areas. Crackfill & seal asphalt sidewalks."|"1"|"S"|"1963"|"10"|"0"||"1"|"S"|"1963"|"10"|"360,000"|"N"|"Add tennis courts. Provide scoreboard on main field."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"25"|"35,000"|"Repair crack and fill joints at custodial area retaining walls. Repair foundation crack at A-House south side, install retaining wall and fill & stabilize soil."|"1"|"S"|"1963"|"15"|"0"||"1"|"S"|"1963"|"15"|"2,000,000"|"Replace gym bleachers, remove auditorium partitions&convert pockets to storage. Minor interior repair at gym backboards&glazed block at coach's office. Secure tops of gym CMU walls. Reconstruct 14 rms to 5 sci, 2 home ec&4general purpose."|"1"|"S"|"1963"|"5"|"975,000"|"Replace corridor & classroom ceilings (re-use existing lighting), except B-house corridors."|"1"|"U"|"1963"|"5"|"600,000"|"Renovate boys & girls locker rooms."|"1"|"U"|"U"|"1963"|"5"|"380,000"|"Replace all corridor, stairwell, and assembly area doors & hardware. Replace Lexan gym vision panel."|"1"|"S"|"1963"|"5"|"6,000"|"Replace 6 broken treads on main entry stairs."|"1"|"U"|"1997"|"0"|"0"|"Being repaired in 2011."|"1"|"1"|"S"|"1963"|"10"|"94,000"|"Replace/provide hand dryers with Dyson, lightning protection & additional outlets (5 CR's), repair rooftop conduit."|"1"|"S"|"1995"|"5"|"45,000"|"Provide additional BR lighting & stairwell lighting, exterior lightin (12)."|"1"|"1"|"S"|"1999"|"9"|"985,000"|"Replace security system, data, IP telephony, repalce clock system, repair/replace PA/intercom wiring & gym/cafeteria/LGI sound systems."|"0"||||"0"||"1"|"COMMON"|"S"|"1963"|"5"|"84,000"|"Replace carpet/VAT at business office, Superintendent's office, personnel, curriculum & transportation offices."|"1"|"INSTRUCT,COMMON"|"S"|"1963"|"10"|"100,000"|"Remove VAT in 16 small rooms, middle C-house & some corridor areas and replace with VCT."|"1"|"COMMON"|"S"|"1963"|"10"|"0"||"1"|"COMMON"|"S"|"1963"|"10"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Concrete joist/slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"25"|"0"||"CONCRETE,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1963"|"10"|"125,000"|"Minor brick masonry repair upper auditorium and A-wing stairs. Replace slate window sills."|"1"|"MASONRY"|"S"|"1963"|"10"|"37,000"|"Reconstruct upper 4 courses of chimney & replace concrete cap, misc. repointing. Add stainless steel cap."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1963"|"5"|"225,000"|"Replace all exterior doors & frames including courtyard."|"1"|"S"|"1963"|"0"|"45,000"|"Replace 4 stairways. Add handrail at one location."|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2000"|"15"|"0"||"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"0"|"360,000"|"Cut away roofing at B-house link corridor scupper for drainage. Leaks at penthouse A & B, but roof under warranty. Blisters need warranty repair."|"1"|"PLASTIC"|"U"|"1963"|"10"|"0"|"Replace all skylights."|"1"|"COPPER"|"S"|"1963"|"5"|"152,000"|"Provide additional valves, gas shutoffs in sciene rooms & boiler room, replace water main valve."|"1"|"IRON"|"S"|"1963"|"5"|"26,000"|"Roof vent caps/clear vents."|"1"|"OIL,NAT_GAS"|"S"|"2004"|"14"|"10,000"|"Remove abandoned DHWST"|"1"|"S"|"1963"|"5"|"97,000"|"Provide automatic sensing faucets/flushometers, provide eyewash on nurses sink & in 4 science classrooms."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1963"|"5"|"713,000"|"Replace 2 original boilers, replace high/low safeties on 2 boilers."|"1"|"S"|"1963"|"5"|"0"||"1"|"S"|"1990"|"5"|"2,680,000"|"A/C LGI, library C & A house CR's & music suite."|"1"|"S"|"1963"|"5"|"200,000"|"Provide FAI for computer lab, 2 kiln hoods & uncover C22 FAI."|"1"|"S"|"1963"|"10"|"13,000"|"Provide additional isolation valves in A house."|"1"|"S"|"1963"|"10"|"0"||"1"|"S"|"1990"|"5"|"290,000"|"Refurbish ATC system, provide energy management."|"1"|"S"|"1999"|"9"|"26,000"|"Repair fire alarm system."|"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1963"|"1963"|"0"||"1"|"S"|"1990"|"10"|"45,000"|"Provide additional emergency lighting in band room & chorus, change exits to LED, replace emergency lighting units."|"1"|"NF"|"1963"|"0"|"250,000"|"Replace generator."|"1"|"0"|"880,000"|"Convert one auditorium doorway alcove for ADA (add pushbuttons). Convert 2 toilets in each wing/floor for ADA. Add elevator at A-wing."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"1"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"1"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"|"0"|||"0"|"1"|"LIGHTING"|"WARMING"|"1"|"1"|"0"|"GOOD"|"Create multi-purpose room in C. House commons ($360,000)"|"12,465,500"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 10:11:07 AM| 650|"Rochester City SD"|"26160001"|"School of the Arts"|"0018"|"08/06/2010"|"45 PRINCE ST "|"ROCHESTER "|" 14608"|"ANNUAL"|"06/01/2011"|"1994"|"278139"|"4"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"1144"|"7,8,9,10,11,12"|"0"|"0"|"0"|"1144"|"0"|"0"|||"79"|"65713"|"ART,AUDITORIUM,CAFE,GYM,KITCHEN,LIBBRARY,SCIENCELAB"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"25"|"0"|"water service owned by public utility"|"1"|"MUN_UTILIT"|"S"|"1994"|"25"|"0"|"sanitary service owned by public utilty"|"1"|"S"|"1994"|"25"|"0"|"gas service owned by public utility"|"1"|"UTIL"|"BELOW"|"S"|"1994"|"20"|"0"||"1"|"S"|"1994"|"25"|"0"||"0"||||"0"||"1"|"S"|"1994"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1994"|"10"|"0"|"resurface north parking lot. replace bumper blocks. replace curbing along western portion of SME and grading improvements behind new curbing"|"1"|"CONCRETE"|"S"|"1994"|"20"|"0"||"0"||||"0"||"1"|"S"|"1994"|"15"|"0"|"N"|"site fencing: replace sections of 6' H at north and east boundaries"|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1994"|"50"|"0"||"1"|"S"|"1994"|"50"|"0"||"1"|"S"|"1994"|"50"|"0"|"replace gym wall pads, repair and refinish various column wraps, repair cracked CWT at various locations (10 SF)"|"1"|"S"|"1994"|"20"|"0"|"replace soiled ceiling tiles at various locations (approx. 80 sf)"|"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"S"|"1994"|"20"|"0"|"replace gym divider"|"1"|"S"|"1994"|"50"|"0"||"1"|"S"|"1994"|"20"|"0"||"1"|"1"|"S"|"1994"|"20"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"1"|"S"|"2003"|"10"|"0"|"provide wireless clock system"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"1994"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1994"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1994"|"20"|"0"||"1"|"COMMON"|"S"|"1994"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1994"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"50"|"0"||"1"|"MASONRY"|"S"|"1994"|"50"|"0"||"1"|"MASONRY"|"S"|"1928"|"50"|"0"||"S"|"S"|"0"|"1"|"1994"|"10"|"0"||"1"|"S"|"1994"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"N"|"1994"|"20"|"0"|"replace broken glass block at several openings and reposition and seal several wracked windows."|"METONMET,OTHER"|"SINGLEPLY,SLATE"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"50"|"0"||"1"|"PLASTIC"|"S"|"1994"|"50"|"0"||"1"|"COPPER"|"S"|"1994"|"35"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"35"|"0"|"replace condensate piping for a/c rm a-033"|"1"|"NAT_GAS"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"15"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"1993"|"13"|"0"|"boilers installed in 1993"|"1"|"S"|"1993"|"17"|"0"|"installed with boilers in 1993"|"1"|"S"|"1993"|"10"|"0"|"chillers and cooling tower installed in 1993"|"1"|"S"|"2002"|"10"|"0"|"rooftop AHU installed in 2002"|"1"|"S"|"1993"|"13"|"0"|"installed in 1993"|"1"|"S"|"1993"|"13"|"0"|"installed in 1993"|"1"|"S"|"1993"|"10"|"0"|"installed in 1993"|"1"|"S"|"1994"|"5"|"0"|"complete system replacement to point addressile add strobes to classrooms"|"1"|"S"|"1994"|"5"|"0"|"replace devices as part of complete system replacement"|"1"|"S"|"1994"|"1994"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"242950"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/29/2010 10:12:45 AM| 651|"Minisink Valley CSD"|"44110104"|"Middle (Intermediate) School"|"0012"|"05/12/2010"|"RT 6 PO BOX 217 "|"SLATE HILL "|" 10973"|"ANNUAL"|"03/01/2011"|"1991"|"140,658"|"2"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"1066"|"6,7,8"|"0"|"1"|"1"|"1066"|"0"|"0"|||"53"|"41,436"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"2,000"|"0"|"0"|"S"|"2005"|"25"|"0"|"Fuel storage tank appears to be in satisfactory condition."|"1"|"WELL"|"S"|"1999"|"40"|"0"|"Water storage tank and pump house appear to be in satisfactory condition."|"1"|"OTHER"|"S"|"2000"|"50"|"0"||"1"|"S"|"1991"|"10"|"0"|"Gas service appears to be in satisfactory condition."|"1"|"UTIL"|"BELOW"|"S"|"1990"|"20"|"0"||"1"|"S"|"2004"|"50"|"10,000"|"Install 400 LF of perforated underdrain along northern side of building."|"1"|"S"|"2010"|"50"|"0"||"1"|"S"|"2010"|"50"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2004"|"50"|"0"||"0"||||"0"||"1"|"S"|"2004"|"50"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"740,000"|"Replace asphalt from Route 6 through parking area at front of MS (16,340 SY)."|"1"|"CONCRETE"|"S"|"2010"|"30"|"70,000"|"Replace sidewalk along north side of building and area access (9,360 SF)."|"0"||||"0"||"1"|"S"|"2010"|"50"|"15,000"|"N"|"Regrade/seed embankment along southern perimeter of rear drop-off loop (4,000 SY)."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2005"|"95"|"0"||"1"|"S"|"2005"|"75"|"0"||"1"|"S"|"2005"|"75"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"35"|"30,000"|"Boys and Girls locker rooms require lockers to be prepared and painted."|"1"|"S"|"S"|"2005"|"30"|"0"||"1"|"S"|"2005"|"75"|"0"||"1"|"S"|"1990"|"60"|"0"||"1"|"1"|"S"|"1990"|"20"|"3,000"|"Replace (4) exterior lighting timers in main electric room. Install contactors and connect to DDC system."|"1"|"E"|"2010"|"30"|"0"||"1"|"1"|"S"|"2005"|"20"|"28,000"|"Replace PA wiring and speakers which have reach the end of useful life. Enclose exposed control cable in appropriate raceways at rear of auditorium."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"15"|"0"||"1"|"COMMON"|"S"|"2005"|"25"|"0"||"1"|"COMMON"|"S"|"1990"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2005"|"75"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"vehicle damage at main entrance wall"|"S"|"2005"|"70"|"32,000"|"Replaee wall along northern side of building (700 SF)."|"1"|"MASONRY,METAL"|"S"|"2010"|"75"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"30"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"2005"|"30"|"475,000"|"Windows in original 1990 building have fogged glazing. Replace with units to match additions. Remove and reinstall existing window shades."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"25"|"0"||"1"|"PLASTIC"|"E"|"2010"|"25"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2005"|"60"|"0"||"1"|"IRON,COPPER"|"E"|"2005"|"60"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"9,000"|"Add eye wash station in boiler room. Wash fountains in original building don't shut off dependably. Repair or replace solenoid valves and install strainers at 8 units."|"0"||"1"|"BOILERWATE"||"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"|"Fuel oil transfer pumps, oil and gas piping in satisfactory condition."|"1"|"S"|"2005"|"15"|"0"|"The 2005 addition is in excellent condition and the original 1991 equipment is nearing the end of its useful life. See item 78 for more information."|"1"|"S"|"2005"|"20"|"2,732,000"|"Replace the library, auditorium, stage, main office, (3) gyms rooftop units or interior air handlers. These are portions of the building were not renovated in 2005. Pricing includes arch and electrical work."|"1"|"S"|"2005"|"45"|"0"||"1"|"S"|"2005"|"20"|"0"|"2005 systems are in excellent shape. Original building equipment is nearing the end of its useful life. Refer to Item 78."|"1"|"S"|"2005"|"15"|"0"||"1"|"E"|"2010"|"20"|"2,500"|"By code requirement, add natural gas alarm system in boiler room."|"1"|"E"|"2005"|"20"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2010"|"15"|"27,500"|"Recommend adding aisle lighting in auditorium. By code requirement, add emergency egress lighting outside every exit door. (approximately 25 locations)."|"1"|"S"|"1990"|"10"|"125,000"|"Replace 100 KW generator nearing end of its useful life. Relocate unit outside and install as Level 1. Cost includes trenching and concrete pad."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,FRIDGE,LIGHTING"|"FULL"|"0"|"0"|"1"|"GOOD"||"5,588,700"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/29/2010 10:13:45 AM| 654|"Warsaw CSD"|"67150104"|"Elementary"|"0001"|"06/25/10"|"153 W BUFFALO ST "|"WARSAW "|" 14569"|"ANNUAL"|"08/01/2011"|"1953"|"100,303"|"2"|"8"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"486"|"Pre-K,K,1,2,3,4,5"|"0"|"1"|"0"|"486"|"0"|"0"|||"24"|"20,063"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"30"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"375,000"|"Replace concrete retaining wall adjacent to Oatka Creek"|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"MUNI"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"4"|"968,750"|"Replace maintenance drive asphalt; add parent drop-off loop; replace creek wall; add marquee board for announcements."|"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"4"|"46,250"|"Replace sidewalk at Exit 2 and miscellaneous broken areas."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2001"|"4"|"22,500"|"Y"|"Install climbing wall at playground."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"1992"|"35"|"0"||"1"|"S"|"1992"|"35"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"S"|"2002"|"20"|"8,750"|"Replace north stage doors; Kindergarten hallway control doors."|"1"|"S"|"1993"|"15"|"0"||"1"|"S"|"1993"|"15"|"0"||"1"|"1"|"S"|"2002"|"20"|"18,750"|"Install demand meter."|"1"|"S"|"2002"|"15"|"97,500"|"Replace Auditorium stage, gym and boiler room lighting."|"1"|"1"|"S"|"2002"|"5"|"261,250"|"Replace stage sound system, install Kindergarten computer stations, Auditorium speakers for PA; replace telephones with VOIP system; add exterior speakers and Auditorium speakers for special announcements; add Auditorium clock."|"0"||||"0"||"0"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"4"|"500,000"|"Remodel locker rooms."|"1"|"COMMON"|"S"|"2002"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"1"|"MASONRY"|"S"|"1953"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"15,000"|"Replace six vestibule doors."|"1"|"S"|"2002"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1990"|"4"|"51,250"|"Replace miscellaneous glass block; replace 1992 windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"4"|"1,500,000"|"Replace roof."|"1"|"PLASTIC"|"S"|"2002"|"4"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"25"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"3"|"187,500"|"Remodel eight toilet rooms."|"0"||"1"|"BOILERWATE"||"S"|"2002"|"20"|"7,500"|"Remove incinerator."|"1"|"S"|"1992"|"10"|"0"||"1"|"S"|"2002"|"15"|"18,750"|"Add cooling to Server Room 134A."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"31,250"|"Add DDC controls and replace walk-in cooler / freezer."|"1"|"S"|"2002"|"10"|"22,500"|"Add FA door holders at Kindergarten, Cafeteria and Auditorium."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"1"|"1"|"1"|"0"||"FULL"||"1"||"GOOD"||"3,757,500"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"Robert J. Nordin, AIA, LEED AP"|"028213"|"I ACCEPT"|12/29/2010 10:25:13 AM| 656|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"COOPERS WB19-MAINTENANCE "|"3057"|"05/11/2010"|"1 VOCATIONAL DRIVE "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1999"|"3274"|"1"|"2"|"1"|"DISTRICT"|"OTHER"||"0"|||"0"|"0"||||||"0"|"0"|"OTHER"|"Maintenance Shop"|"0"||||||||"0"||"1"|"WELL"|"S"|"1999"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"25"|"0"||"0"||||"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"10"|"0"||"1"|"CONCRETE"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"45"|"0"||"0"||||"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"S"|"1999"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1999"|"25"|"0"||"1"|"S"|"1999"|"10"|"2,500"|"Replace existing wtih T8 fixtures. "|"1"|"1"|"S"|"2002"|"5"|"5,000"|"New PA System. "|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1999"|"10"|"0"||"1"|"COMMON"|"S"|"1999"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"45"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"40"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1999"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"NA"|"1999"|"15"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1999"|"20"|"0"||"1"|"IRON"|"S"|"1999"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1999"|"6"|"0"||"1"|"S"|"1999"|"15"|"0"||"0"||"1"|"OTHER"||"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"1"|"5,000"|"Replace and rearrange toilet room fixture to be accessible. "|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"|||"0"|"0"|"0"|"FAIR"||"0"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/29/2010 10:43:56 AM| 657|"Plainview-Old Bethpage CSD"|"28050406"|"Jamaica Avenue Elementary School"|"0004"|"09/30/2010"|"JAMAICA AVENUE "|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1953"|"85057"|"2"|"10"|"0"|"PART"|"OTHER"|"Adult Ed - Athletics"|"400"|"UNGRD"|"0"|"0"|"0"|"400"|"0"|"0"|||"46"|"36,800"|"AUDITORIUM,CAFE,GYM,KITCHEN"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"35"|"4,500"|"Provide cage for overfill alarm & repair alarm condition."|"1"|"MUN_UTILIT"|"S"|"1959"|"5"|"96,000"|"Provide additiona site hydrants."|"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1954"|"10"|"0"||"1"|"S"|"1953"|"5"|"0"||"1"|"S"|"1953"|"10"|"0"||"0"||||"0"||"1"|"S"|"1953"|"10"|"0"||"0"|||||||"0"||"1"|"S"|"1953"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT"|"U"|"1953"|"0"|"425,000"|"Partial curb replacement at NW lot & bus loop. Repave NW lot, bus loop & S lot. Repair& overlay E lot. Minor repair, crackfill & seal SW lot&small loop. Replace fence E lot & add bollards S lot."|"1"|"CONCRETE,ASPHALT"|"U"|"1963"|"5"|"89,500"|"Replace main entry sidewalks east of main entry. Add sidewalk along north side of south lot, and sidewalk from south lot to gym."|"1"|"U"|"1953"|"5"|"16,000"|"Repave west asphalt play area."|"1"|"S"|"1953"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1953"|"15"|"0"||"1"|"S"|"1959"|"15"|"0"||"1"|"S"|"1959"|"15"|"187,500"|"Replace gym bleachers (4) 30' sections."|"1"|"U"|"1953"|"10"|"132,000"|"Replace gym asbestos ceiling, asbestos ceiling in custodial area, custodial closet (whole area) & 6 closets."|"0"||||"0"||"1"|"S"|"U"|"1953"|"10"|"15,000"|"Remove hold opens, replace hardware as required."|"1"|"S"|"1953"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1954"|"5"|"10,000"|"Provide GFI receptacles & repair lightning protection system."|"1"|"S"|"1990"|"5"|"8,000"|"Repair 3 exterior security lights & 2 lighting poles."|"0"|||||"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"1953"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1953"|"10"|"0"||"1"|"COMMON"|"S"|"1953"|"10"|"0"||"1"|"COMMON"|"S"|"1959"|"10"|"0"||"SLABGRADE,OTHER"|"One way reinforced concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1953"|"15"|"0"||"MASONRY,STEEL"|"0"|"1"||"1"|"0"|"0"|"1"|"1"||"S"|"1953"|"15"|"0"|"Reconstruction to be performed Summer 2011."|"1"|"MASONRY"|"S"|"1953"|"15"|"0"|"Reconstruction to be performed Summer 2011."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1959"|"5"|"54,000"|"Replace boiler room & custodial doors, doors & frame at exit 4, gym exterior doors, single friendship door & all purpose rooms door."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1959"|"5"|"1,150,000"|"Replace windows & paint lintels."|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"U"|"1953"|"0"|"0"|"Replacement planned Summer 2011."|"0"|||||"0"||"1"|"COPPER"|"S"|"1954"|"5"|"20,000"|"Provide emergency gas shutoff in kitchen area & BR."|"1"|"IRON"|"S"|"1954"|"5"|"16,000"|"Clear roof vents/provide caps, repair leaking sanitary line."|"1"|"OIL,NAT_GAS"|"S"|"2003"|"13"|"26,500"|"Remove abandoned DHWST replace DHWH."|"1"|"S"|"1954"|"5"|"13,500"|"Replace 3 missing sinks, remove drinking fountains from sinks, provide vacuum breaker on slop sink, provide emergency eyewash stations (2)."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1954"|"5"|"600,000"|"Replace 2 original boilers & condensate receiver."|"1"|"S"|"1954"|"5"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1954"|"5"|"206,000"|"Refurbish gym H&V unit, refurbish UV's, provide vent for records room, repair/replace exhaust fans (20)."|"1"|"S"|"1954"|"10"|"0"||"1"|"S"|"1954"|"10"|"0"||"1"|"S"|"1990"|"5"|"185,000"|"Tie exhaust fans to day/night system, refurbish ATC system, provide EM system."|"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"2008"|"12"|"0"||"1"|"S"|"1954"|"1954"|"0"||"1"|"S"|"1990"|"5"|"7,000"|"Add exit/emergency lighting in basement hallway."|"0"||||"0"||"1"|"0"|"30,000"|"Convert unisex toilet room in main lobby ADA"|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"1"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"1"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||"WARMING"|"0"|"0"|"1"|"GOOD"||"3,202,000"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 10:47:14 AM| 658|"Cobleskill-Richmondville CSD"|"54110206"|"Joseph B. Radez Elementary"|"0015"|"10/08/2010"|"319 Main St "|"RICHMONDVILLE "|" 12149"|"ANNUAL"|"01/01/2011"|"1932"|"110300"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"306"|"Pre-K,K,1,2,3,4,5"|"0"|"0"|"1"|"306"|"0"|"0"|||"38"|"34072"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"8000"|"S"|"1989"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1987"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"10"|"0"||"1"|"S"|"2003"|"20"|"0"|"LP to kitchen equipment"|"1"|"UTIL"|"BELOW"|"S"|"1987"|"15"|"0"|"Recommend site lighting upgrades for rear parking area - 17,700"|"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"S"|"2003"|"20"|"0"||"0"||||"0"||"1"|"MUNI"||"0"|"S"|"1989"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"20"|"0"|"Partial replacement 2003, remainder 2009"|"1"|"CONCRETE"|"S"|"2009"|"5"|"8000"|"Replace exterior stair, building front, west side"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"1986"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"5"|"15000"|"Water damage locker room ceilings - remove, replace"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"S"|"2003"|"5"|"30000"|"Many original know locksets remain, non ADA, near end of life"|"1"|"S"|"2003"|"10"|"0"|"Add rubber treads, risers at original building"|"1"|"S"|"1987"|"15"|"0"||"1"|"1"|"S"|"2003"|"5"|"7000"|"Replace 2 outdated panels - 7,000. Recommend TVSS protection for computers - 700."|"1"|"S"|"2009"|"5"|"28000"|"Partial replacement 2003, 2009. replace gym lighting T12 - 24,000, Stage lighting - 4,000."|"1"|"1"|"S"|"2004"|"15"|"0"|"Telephone head end may be at maximum capacity and require expansion - 10,000."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"|"Library"|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"20"|"0"|"Partial replacement 2003, 2009 and 2010"|"1"|"COMMON"|"S"|"2003"|"20"|"0"||"1"|"COMMON"|"S"|"1986"|"20"|"0"|"Gymnasium"|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"20"|"0"|"Minor cracking in 1954 corridor terrazzo, slab on grade, not displaced."|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"S"|"2009"|"5"|"5000"|"Sealant replacement at south side entry, 1932 stair. Some rust at lintels."|"1"|"MASONRY"|"S"|"2009"|"20"|"0"||"1"|"MASONRY"|"S"|"2003"|"20"|"0"||"S"|"S"|"0"|"1"|"2003"|"5"|"35000"|"Doors in 1986 addition, main entry and gym exits"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"10"|"0"|"Partial replacement 1986"|"METONMET,CONMETMET"|"SINGLEPLY,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"10"|"0"|"Roof system at gymnasium addition replaced 1999."|"1"|"PLASTIC"|"S"|"1999"|"15"|"0"||"1"|"COPPER"|"S"|"2003"|"20"|"0"||"1"|"IRON"|"S"|"2003"|"5"|"150000"|"Replace basement drainage piping due to vintage"|"1"|"OIL"|"S"|"2003"|"15"|"0"||"1"|"S"|"2009"|"5"|"5000"|"Partial replacements 1999, 2003, 2009. Replace floor mounted urinal in 124A."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1987"|"7"|"0"||"1"|"S"|"1987"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2003"|"10"|"0"|"gymnasium equipment on old pneumatic system, to be added to DDC."|"1"|"S"|"2003"|"20"|"0"|"Library and court require notification devices - 2,000"|"1"|"S"|"2003"|"20"|"0"|"Devices added 2009. Library requires additional devices - 1,200"|"1"|"S"|"2003"|"2003"|"0"|"Kitchen ansul system. Standpipe at stage."|"1"|"S"|"2009"|"20"|"0"|"Additional devices added 2009. Recommend additional fixtures in boiler room and courtyard - 3,200."|"1"|"S"|"2009"|"1"|"70000"|"Generator relocated from Shelter building 2009, vintage 1960. Feeders, panels, switch 2009."|"1"|"0"|"40000"|"Door hardware not lever type, stage not accessible."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"|"Boiler room and stage levels poor"|"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"||"0"|||"1"|"1"||"Water damage at locker room ceilings."|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"1"|"AREAWIDE"|"0"|"1"|"0"|"1"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"1"|"0"|"GOOD"||"393000"|"S"|"0"|"CSArch"|"40 Beaver St, Albany, Ny 12207"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/29/2010 10:55:17 AM| 662|"Franklin CSD"|"12070104"|"Stone Hall"|"0002"|"09/07/2010"|"26 INSTITUTE ST "|"FRANKLIN "|" 13775"|"ANNUAL"|"10/31/2011"|"1855"|"6620"|"3"|"0"|"0"|"DISTRICT"|"OTHER"|"storage/museum"|"0"|||"0"|"0"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1986"|"11"|"0"||"1"|"MUN_UTILIT"|"S"|"1948"|"5"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"|"fed from main building."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"2"|"10200"|"replace dumpster pan."|"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1855"|"20"|"0"||"1"|"S"|"1855"|"19"|"0"||"1"|"S"|"1985"|"15"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"|||"0"|"0"||"1"|"S"|"S"|"1948"|"2"|"0"||"1"|"S"|"1855"|"2"|"0"||"0"|||"0"|"0"||"1"|"1"|"S"|"1970"|"5"|"150000"|"all original distribution."|"1"|"S"|"1985"|"5"|"40000"|"existing t12 system. replace with t8 system."|"1"|"1"|"S"|"2006"|"15"|"0"||"0"|||"0"|"0"||"1"|"COMMON"|"S"|"1985"|"5"|"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1948"|"20"|"0"||"1"|"COMMON"|"S"|"1948"|"20"|"0"||"WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1855"|"20"|"0"||"OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1855"|"20"|"0"||"1"|"MASONRY"|"S"|"1855"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1982"|"10"|"0"||"1"|"S"|"1948"|"20"|"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1948"|"5"|"0"|"recommend to replace windows to match historically."|"OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1976"|"10"|"10000"|"provide canopy at West side entrance."|"0"|||||"0"||"1"|"GALVANIZED"|"S"|"1953"|"20"|"0"||"1"|"IRON"|"S"|"1953"|"20"|"0"||"0"|||||"0"||"1"|"S"|"1953"|"10"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"15"|"0"||"0"||||"0"||"0"||||"95000"|"initiate project to provide HVAC system."|"1"|"U"|"1995"|"1"|"18000"|"replace piping and convectors."|"0"||||"0"||"0"||||"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"0"|"90000"|"initiate project to make facility accessible. "|"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"POOR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"POOR"|"0"|"POOR"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"223200"|"U"|"1"|"Clark Patterson Lee"|"59 Court Street Binghamton, N.Y. 13901"|"1-800-274-9000"|"rwarholic@clarkpatterson.com"|"John J. Martin, PE"|"057961"|"I ACCEPT"|12/29/2010 11:31:42 AM| 665|"Randolph CSD"|"04300104"|"Junior/Senior/Middle/High School"|"0001"|"05/18/2010"|"18 Main Street"|"Randolph"|" 14772"|"ANNUAL"|"07/01/2011"|"1930"|"175,304"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"500"|"7,8,9,10,11,12"|"0"|"1"|"1"|"500"|"0"|"0"|||"25"|"20,625"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"SITESEPT"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"3"|"95,000"|"Reconstruct entrance and exit drives."|"1"|"CONCRETE"|"S"|"2002"|"5"|"0"||"0"||||"0"||"1"|"S"|"2003"|"5"|"230,000"|"N"|"Reconstruct retaining wall at tennis courts and resurface track."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2005"|"20"|"22,000"|"Replace ceiling at Kitchen."|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"S"|"2005"|"20"|"52,000"|"Replace interior doors at 1965 addition."|"1"|"S"|"2005"|"30"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"1"|"S"|"2001"|"25"|"0"||"1"|"S"|"2001"|"20"|"10,000"|"Replace lighting at Kitchen."|"1"|"1"|"S"|"2001"|"5"|"130,000"|"Upgrade security, clock and LAN/WAN systems."|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"80,000"|"Masonry restoration."|"1"|"MASONRY"|"S"|"1993"|"10"|"0"||"1"|"MASONRY"|"S"|"1993"|"10"|"0"||"S"|"S"|"0"|"1"|"2005"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"6"|"465,000"|"Reconstruct slate roof and 1965 building roof."|"1"|"PLASTIC"|"S"|"2005"|"6"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1957"|"1"|"55,000"|"Replace pumps, balancing valves, mixing valves, frost free hydrants."|"1"|"PVC"|"S"|"1957"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1957"|"1"|"80,000"|"Inadequate hot water; replace heaters, mixing valves and pumps."|"1"|"S"|"2001"|"15"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"1976"|"5"|"500,000"|"Replace steam boilers with hot water boiler system."|"1"|"S"|"1976"|"20"|"0"||"1"|"S"|"2004"|"10"|"330,000"|"Replace aging split A/C system, PTAC units and rooftop units."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"10"|"30,000"|"Replace original steam piping to classrooms."|"1"|"S"|"2004"|"1"|"100,000"|"Replace duct insulation and jacketing above roof areas."|"1"|"S"|"2004"|"10"|"150,000"|"Update pneumatic controls to DDC."|"1"|"S"|"2000"|"20"|"40,000"|"Extend audio visual signal to non-compliant areas."|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"180,000"|"Code required life safety and equipment circuit segregation."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"2,819,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/29/2010 11:52:08 AM| 666|"Plainview-Old Bethpage CSD"|"28050406"|"Old Bethpage Elementary School"|"0002"|"09/27/2010"|"ROUND SWAMP ROAD "|"OLD BETHPAGE "|" 11804"|"ANNUAL"|"04/01/2011"|"1956"|"52985"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"385"|"1,2,3,4"|"0"|"0"|"0"|"385"|"0"|"0"|||"35"|"28,000"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1995"|"35"|"0"||"1"|"MUN_UTILIT"|"S"|"1956"|"5"|"100,000"|"Provide additional site fire hydrant."|"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"2000"|"40"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"40"|"0"||"1"|"S"|"1956"|"10"|"500"|"Reconnect roof drain line outside computer room."|"0"||||"0"||"1"|"S"|"1956"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1956"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1956"|"10"|"85,000"|"Replace curbing around teachers lot. Crackfill & seal parking lot & driveway."|"1"|"CONCRETE,ASPHALT"|"S"|"1956"|"5"|"52,000"|"Replace concrete outside kitchen and remove abandoned vault. Replace east side, south side and parent loop asphalt walks."|"1"|"S"|"2009"|"5"|"68,000"|"Replace asphalt play area north side of building and curbing."|"1"|"S"|"1956"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"25"|"95,000"|"Construct outside entry and storage room in basement."|"1"|"S"|"1956"|"15"|"0"||"1"|"S"|"1956"|"15"|"12,000"|"Replace chalkboards with whiteboards in 8 classrooms."|"1"|"S"|"1956"|"10"|"24,000"|"Remove hard ceiling and install acoustic ceiling at art room and adjacent speech room. Remove & replace asbestos ceiling at store room & kitchen delivery hall."|"0"||||"0"||"1"|"S"|"S"|"1956"|"10"|"1,000"|"Sound seals at art room doors & gym."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1956"|"5"|"125,000"|"Provide switches for A/C's, replace 2 GFI's, electric dryers, elec. in CR's, lightning protection, replace 2 damaged GFI receptacles on exterior."|"1"|"S"|"1995"|"5"|"12,000"|"Provide pole light by visitors lot, replace lobby lighting, repair/replace 5 wall pacs."|"1"|"1"|"S"|"1995"|"15"|"654,500"|"Provide IP telephony, data network upgrades, provide additional CCTV cameras, card access, replace PA/intercom, gym sound system, add ceiling projector to MP room & theatrical lighting in MP room."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1956"|"5"|"3,50"|"Replace carpet in room 9 (speech)."|"1"|"INSTRUCT,COMMON"|"S"|"1956"|"10"|"0"||"1"|"COMMON"|"S"|"1956"|"10"|"0"||"1"|"COMMON"|"S"|"1956"|"10"|"0"||"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"15"|"2,500"|"Patch improperly patched hole in floor below kitchen."|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1956"|"15"|"95,000"|"Build canopy at north entrance. Reconstruct interior wall by kitchen. Minor masonry tuckpointing. Reconstruct bowing brick outside nurse."|"1"|"MASONRY"|"S"|"1956"|"5"|"52,000"|"Tuckpoint & repair entire chimney. Replace concrete cap. Add stainless steel cap."|"1"|"MASONRY"|"E"|"2000"|"15"|"0"||"S"|"S"|"0"|"1"|"1956"|"10"|"10,000"|"Replace main entry saddles (4). Replace library door saddles."|"1"|"S"|"2009"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2000"|"15"|"0"||"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"1"||"S"|"2000"|"5"|"340,000"|"Repair blisters, snake out 3 roof drains, replace one of these 3, recoat roof. Replace skylight."|"1"|"PLASTIC"|"U"|"1956"|"5"|"0"||"1"|"COPPER"|"S"|"1956"|"5"|"10,000"|"Provide gas emergency shutoff in BR."|"1"|"IRON"|"S"|"1956"|"10"|"14,000"|"Provide vent caps on roof vents, replace missing exterior vent cover."|"1"|"OIL,NAT_GAS"|"S"|"2004"|"14"|"0"||"1"|"S"|"1956"|"10"|"20,000"|"Provide hands free faucets."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2004"|"5"|"4,000"|"Replace ball valve on boiler #2."|"1"|"S"|"2004"|"43"|"0"||"1"|"S"|"2004"|"15"|"260,000"|"Provide A/C for MP room."|"1"|"S"|"1956"|"5"|"164,000"|"Provide separate exhaust system for MP room, provide FAI for band room & speech room, replace older rooftop exhaust fans (16)."|"1"|"S"|"1956"|"10"|"76,500"|"Replace steam traps."|"1"|"S"|"2000"|"10"|"13,000"|"Replace damaged RTU ductwork insulation."|"1"|"S"|"1956"|"5"|"230,000"|"Provide energy management system, refurbish ATC system, tie exhaust fans to day/night system."|"1"|"S"|"2000"|"15"|"21,000"|"Provide additional horn/strobe units in 4 areas, repair fire alarm system, connect Ansul in kitchen to FA."|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1956"|"1956"|"0"||"1"|"S"|"1995"|"5"|"7,000"|"Replace exit signs with LED type, replace emergency light in gym."|"0"||||"0"||"1"|"1"|"60,000"|"Convert art toilet for HCA and open to corridor. Reconstruct nurses toilet for HCA."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"||"Replace a few ceiling tiles in conjunction with roof work."|"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"1"|"1"|"FAIR"|"Request to add 2 clasrooms and toilets: $1,300,000"|"2,614,000"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 11:55:46 AM| 667|"Lansingburgh CSD"|"49060106"|"Lansingburgh Senior High School"|"0010"|"6/16/10"|"320 7th Avenue"|"Troy"|" 12182"|"ANNUAL"|"01/01/11"|"1967"|"97490"|"3"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"810"|"9,10,11,12"|"0"|"1"|"1"|"810"|"0"|"0"|||"41"|"40120"|"ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"25"|"0"||"1"|"S"|"1981"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2006"|"25"|"42,000"|"Replace exterior lighting."|"1"|"S"|"1975"|"30"|"0"|"Municipal upgrades needed - system undersized."|"0"||||"0"||"1"|"S"|"2006"|"35"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1975"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"0"||"1"|"CONCRETE"|"S"|"2003"|"25"|"75,000"|"Replace deteriorated concrete walk and granite stairs. "|"0"||||"0"||"1"|"S"|"2009"|"20"|"1,607,500"|"N"|"Tennis court upgrades, renovate softball fields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"40"|"0"||"1"|"S"|"1998"|"37"|"0"||"1"|"S"|"1998"|"37"|"0"||"1"|"S"|"1998"|"10"|"25,000"|"Ongoing replacement of damaged ceiling tile."|"1"|"S"|"2006"|"15"|"0"|"Replace corridor lockers in original part of school. "|"1"|"S"|"S"|"1967"|"5"|"180,000"|"Provide doors, hardware, vision panels. "|"1"|"S"|"1998"|"37"|"20,000"|"Improve stairs for handicapped accessibility in one stairwell - add handrails. "|"1"|"S"|"1998"|"38"|"20,000"|"Elevator needs Sump Pump; needs retrofitting due to new req for hydraulic oil."|"1"|"1"|"S"|"1998"|"15"|"184,000"|"Replace main service disconnect and older electric panels."|"1"|"S"|"1998"|"15"|"25,000"|"Replace exterior & corridor lighting, single strip lighting - 2x4."|"1"|"1"|"S"|"1988"|"5"|"937,000"|"Replace computer network, clock, sound, video systems. "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"2005"|"4"|"21,000"|"Replace worn carpet with VCT. "|"1"|"INSTRUCT,COMMON"|"S"|"2005"|"4"|"150,000"|"Replace damaged VAT/VCT and replace carpet with VCT."|"1"|"COMMON"|"S"|"2005"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"E"|"2006"|"25"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"40"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1967"|"40"|"40,000"|"Repoint walls. "|"1"|"MASONRY"|"S"|"1967"|"10"|"23,000"|"Needs repointing. "|"1"|"MASONRY"|"S"|"1998"|"10"|"0"||"S"|"S"|"1"|"1"|"2008"|"8"|"82,000"|"Replace doors storefront at front entrance and secondary doors. "|"1"|"S"|"1967"|"57"|"0"|"Re-point granite steps."|"0"|||||"0"||"1"|"WOODCLAD"|"E"|"Y"|"2009"|"25"|"0"||"CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"24"|"0"||"1"|"PLASTIC"|"S"|"2009"|"24"|"0"||"1"|"COPPER"|"S"|"1967"|"2"|"75,575"|"Install backflow devices, isolation valves, recirc line. "|"1"|"IRON,COPPER"|"S"|"1967"|"2"|"48,750"|"Provide grease trap for kitchen. "|"1"|"NAT_GAS"|"S"|"1998"|"8"|"0"||"1"|"S"|"2006"|"10"|"72,000"|"Replace fixtures in main toilet rooms, add clay trap to art room."|"0"||"1"|"BOILERSTEA"||"S"|"1988"|"10"|"0"|"Heated w/ hot water, but making steam."|"1"|"S"|"1998"|"40"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"2006"|"28"|"0"||"1"|"S"|"1998"|"35"|"0"||"1"|"S"|"1998"|"25"|"0"||"1"|"S"|"1988"|"5"|"90,000"|"Replace remaining with DDC."|"1"|"E"|"2002"|"21"|"0"||"1"|"E"|"2002"|"21"|"0"||"1"|"S"|"2007"|"2007"|"0"||"1"|"E"|"2009"|"25"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"1"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"254,500"|"S"|"1"|"SEI design group"|"187 Wolf Road, Suite 205, Albany, NY 12205"|"518-435-2467"|"msm@seidesigngroup.com"|"Matt Monaghan"|"029199"|"I ACCEPT"|12/29/2010 11:56:26 AM| 668|"Kenmore-Tonawanda UFSD"|"14260103"|"Kenmore East High School"|"0009"|"07/07/2010"|"350 FRIES RD "|"TONAWANDA "|" 14150"|"ANNUAL"|"07/01/2011"|"1957"|"288965"|"3"|"11"|"4"|"DISTRICT"|"INSTRUCT"||"1140"|"9,10,11,12"|"0"|"0"|"0"|"1140"|"0"|"0"|||"40"|"32509"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"20000"|"S"|"1959"|"5"|"263000"|"Remove underground tank, piping, accessories and contaminated soil"|"1"|"MUN_UTILIT"|"S"|"2000"|"1"|"230000"|"Backflow preventer and enclosure for domestic water and athletic field fire hydrant for Southwest corner of building."|"1"|"MUN_UTILIT"|"S"|"1960"|"10"|"0"||"1"|"S"|"1960"|"1"|"138000"|"Emergency shutoff for science rooms and home economics rooms"|"1"|"UTIL"|"BELOW"|"S"|"1998"|"20"|"0"||"1"|"S"|"1950"|"5"|"15000"|"Replace deteriorated roof drains and piping"|"0"||||"0"||"1"|"S"|"1960"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"450000"|"Replace asphalt paving parking lots and drives"|"1"|"CONCRETE"|"S"|"1994"|"5"|"50000"|"Replace deteriorated and broken concrete sidewalks"|"0"||||"0"||"1"|"E"|"2010"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1966"|"20"|"0"||"1"|"S"|"1966"|"20"|"0"||"1"|"S"|"1966"|"20"|"0"||"1"|"S"|"2002"|"5"|"161000"|"Replace ceiling system in Gymnasium and Cafeteria"|"1"|"S"|"1966"|"3"|"130000"|"Replace lockers in all of the locker rooms"|"1"|"S"|"S"|"2002"|"3"|"60000"|"Replace wood doors at the Gymnasium, Cafeteria and Main Office"|"1"|"S"|"1966"|"20"|"0"||"1"|"S"|"1984"|"3"|"16500"|"Upgrade existing elevator to meet A.D.A. codes"|"1"|"1"|"S"|"2002"|"0"|"20000"|"Provide GFCI receptacles, emergency shutdowns, etc."|"1"|"S"|"2002"|"1"|"230500"|"Replace Auditorium lighting and various older building lighting"|"1"|"1"|"U"|"2002"|"0"|"797500"|"Replace public address (PA) system, clock system, Auditorium sound system, and upgrade telephone system"|"1"|"S"|"1960"|"1"|"575000"|"Replace Pool filtration system, heater, piping and accessories"|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1960"|"3"|"125000"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1966"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1966"|"3"|"100000"|"Masonry restoration required: replacement of brick, repointing, etc."|"1"|"MASONRY"|"S"|"1960"|"3"|"50000"|"Install new cap, replace brick, repoint and regrout masonry"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"1"|"40000"|"Replace miscellaneous exterior doors and replace security system motion sensors"|"1"|"S"|"1966"|"3"|"175000"|"Replace deteriorated concrete stairs and install ramps at entrances to meet A.D.A. codes"|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1984"|"3"|"100000"|"Replace remaining original windows"|"METONMET,CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"1"||"S"|"2009"|"1"|"160000"|"Replace roof system over the Pool and Aux. Gymnasium"|"1"|"PLASTIC"|"S"|"2009"|"1"|"50000"|"Replace existing skylights at Gymnasium and Locker Rooms"|"1"|"COPPER"|"S"|"1960"|"1"|"6000"|"Install backflow preventer on boiler water make-up"|"1"|"IRON,COPPER,PVC"|"S"|"1960"|"1"|"200000"|"Kitchen work: replace grease traps and underground sewers"|"1"|"NAT_GAS"|"S"|"1960"|"1"|"138000"|"Replace hot water heaters, storage tanks, piping and accessories"|"1"|"S"|"2004"|"1"|"432875"|"Renovate Locker Rooms and Cafeteria, hose bibbs in gang lavatories, drinking fountain replacement, replace water heater with non-freeze vacuum breaker type"|"0"||"1"|"BOILERSTEA"||"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1960"|"6"|"0"||"1"|"U"|"1960"|"0"|"2210000"|"Replace unit ventilators, exhaust fans, relief hoods and add ventilation in Data Closets"|"1"|"S"|"1960"|"3"|"310000"|"Replace boiler feed unit, traps and miscellaneous piping"|"1"|"S"|"1960"|"5"|"115000"|"Internally clean ductwork"|"1"|"S"|"2002"|"3"|"640000"|"Update controls on unit ventilators and air handling units"|"1"|"S"|"2002"|"0"|"55000"|"Provide additional code required notification signals"|"1"|"S"|"2002"|"0"|"0"|"Provide additional code required smoke detection"|"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2002"|"0"|"139000"|"Provide exit signage, emergency egress lighting and additional emergency lighting"|"1"|"U"|"1998"|"0"|"288000"|"Replace emergency generator and distribution system"|"1"|"0"|"42000"|"Provide A.D.A. accessibility in the Locker Rooms"|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"INACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"0"|"1"|"FAIR"||"$11,050,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street Williamsville NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/29/2010 12:04:19 PM| 671|"Cobleskill-Richmondville CSD"|"54110206"|"School Bus Garage"|"5006"|"11/10/2010"|"284 Elm Street"|"COBLESKILL "|" 12043"|"ANNUAL"|"01/01/2011"|"1964"|"17900"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus storage and maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"2"|"12000"|"0"|"0"|"S"|"1998"|"20"|"0"|"Diesel and gasoline tanks"|"1"|"WELL"|"S"|"1964"|"15"|"0"||"1"|"SITESEPT"|"S"|"2000"|"15"|"0"|"5000 gallon holding tank and oil separator added 2000"|"1"|"S"|"2000"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"U"|"1964"|"3"|"27000"|"Replace main service entrance panels and outdoor weather head. GFCI at bus receptacles, site lighting adequate."|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"0"|"S"|"1964"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1998"|"5"|"10000"|"Concrete cracking at fuel island, concrete at building entry starting to deteriorate - 10,000. Asphalt broken up and showing some settlement, re-construct within 10 years."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"1"|"0"|"0"|"0"|"S"|"1998"|"5"|"62000"|"Concrete deteriorating at column base and rear wall cold storage building."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"U"|"2000"|"5"|"8000"|"Replace suspended ceilings in locker rooms, bathrooms, offices."|"0"||||"0"||"1"|"S"|"S"|"2000"|"5"|"5000"|"Beyond useful life, missing closers, some non-latching replace 6 doors, frames and hardware."|"1"|"S"|"1964"|"10"|"0"|"Stair to messanine"|"0"||||"0"||"1"|"1"|"S"|"2003"|"15"|"0"||"1"|"U"|"2000"|"5"|"20000"|"Lighting levels poor in general"|"1"|"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2004"|"2"|"27000"|"Some cracking, surface deterioration in shop area. Surface inappropriate for offices."|"0"|||||"0"||"SLABGRADE,CONCRMETAL,OTHER"|"Gravel"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"15"|"0"||"MASONRY,STEEL"|"0"|"1"||"1"|"1"|"0"|"1"|"1"||"U"|"2000"|"2"|"492000"|"Column base deterioration, metal siding damaged and deteriorating, beyond useful life."|"1"|"METAL"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"U"|"U"|"0"|"0"|"2000"|"0"|"1000"|"Boiler room door requires replacement, over head doors near end of useful life."|"0"||||"0"||"0"|||||"0"||"1"|"WOOD"|"S"|"NA"|"1964"|"5"|"1500"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1964"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1964"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"5"|"1500"|"40 gallon, gas"|"1"|"U"|"1964"|"0"|"10000"||"0"||"1"|"FURNACE"||"S"|"1992"|"5"|"8000"|"Furnace in shop area control board replaced 2010, gas unit heaters in shop."|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"|"Paint booth AHU and make up air unit 1999. Inadequate ventilation at offices."|"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"||||"0"|"No alarm system installed - 40,000"|"0"||||"0"|"No smoke detection system installed - 12,000"|"0"||||"0"||"0"||||"0"|"No emergency lights currently installed - 10,000"|"0"||||"0"||"0"|"0"|"22000"|"Available space and use prohibits full interior accessibility."|"POOR"||"POOR"||"0"|"0"|"POOR"||"NA"|"POOR"|"Inadequate lighting levels throughout"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"0"|"FAIR"||"0"|"0"|"0"|"0"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"|"0"|"POOR"|"Undersized in all areas"|"713000"|"U"|"0"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/29/2010 12:48:02 PM| 676|"Plainview-Old Bethpage CSD"|"28050406"|"Parkway Elementary School"|"0008"|"10/01/2010"|"MANETTO HILL ROAD "|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1959"|"58084"|"1"|"4"|"1"|"DISTRICT"|"INSTRUCT"||"357"|"1,2,3,4"|"0"|"1"|"0"|"357"|"0"|"0"|||"23"|"18,400"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1995"|"35"|"1,500"|"Provide cage for overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1959"|"5"|"96,000"|"Provide additional site fire hydrants."|"1"|"MUN_UTILIT"|"S"|"1995"|"35"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1959"|"5"|"0"||"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1959"|"5"|"88,000"|"Replace building-side at bus loop. Minor repair crackfill & seal all pavement except newer NW section."|"1"|"CONCRETE,ASPHALT"|"S"|"1959"|"5"|"40,500"|"Replace approximately 14 flags of settled sidewalk, repave south & west asphalt walks."|"1"|"U"|"1959"|"5"|"52,000"|"Repave asphalt play area - elevation causing flooding at building."|"1"|"S"|"1959"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1959"|"15"|"2,500"|"Repair top of walls at transformer vault."|"1"|"S"|"1959"|"15"|"0"||"1"|"S"|"1959"|"15"|"276,500"|"Renovate conference room & kitchenette furniture,casework&clg).Replace(24)CR sink cabinets. Reconstruct gym office walls thru ceiling to deck. Repair masonry cracks in breezeway.Replace stage rigging & curtains & replace kitchen hot pan."|"1"|"S"|"1959"|"5"|"0"|"Replace all corridor, main office & classroom ceilings. Replace cafeteria & kitchen metal ceilings. Repair stucco entry soffit. Reuse existing lighting."|"0"||||"0"||"1"|"U"|"U"|"1959"|"5"|"76,000"|"Refinish corridor doors & replace hardware. Remove hold-opens from assembly area doors. Replace one set doors & frame at gym for HCA (3x2 leaf).Replace storage doors under stage."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1959"|"5"|"110,000"|"Provide additional outlets in CRs, provide lightning arrestor, provide electric hand dryers, provide new circuit to faculty room."|"1"|"S"|"1990"|"5"|"9,200"|"Provide additional security lighting (4), repair 3 photocells, add lighting to boys BR's."|"1"|"1"|"S"|"1995"|"5"|"722,000"|"Provide IP telephony, data & security upgrades, replace PA/intercom system, replace gym/cafeteria sound system, replace low/unclear speakers, replace main office floor data jack & provide theatrical dimming system."|"0"||||"0"||"1"|"COMMON"|"S"|"1959"|"5"|"0"||"1"|"INSTRUCT"|"U"|"1959"|"10"|"0"|"Classroom VAT to remain."|"1"|"COMMON"|"S"|"1959"|"10"|"0"||"1"|"COMMON"|"U"|"1959"|"5"|"92,000"|"Replace gym wood floor."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1959"|"15"|"0"||"MASONRY,STEEL"|"1"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1959"|"15"|"180,000"|"New canopy for carpool entrance. Replace storage shed. Elastomeric coating on entire building."|"1"|"MASONRY"|"S"|"1959"|"15"|"2,500"|"Repair metal chimney cap."|"1"|"MASONRY"|"S"|"1959"|"15"|"0"||"U"|"S"|"0"|"1"|"1959"|"5"|"92,000"|"Replace all exterior doors & frames except at additions. Replace saddles at 3 pair cafeteria doors."|"1"|"S"|"1959"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1959"|"5"|"1,350,000"|"Replace all original building windows (green panels reported to be transite)."|"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2008"|"15"|"000"||"1"|"PLASTIC"|"U"|"1959"|"5"|"35,000"|"Replace skylights."|"1"|"COPPER"|"S"|"1959"|"5"|"85,000"|"Provide emergency gas shutoff in kitchen & boiler room, replace isolation valves throughout building & in boiler room."|"1"|"IRON"|"S"|"1959"|"5"|"26,000"|"Clear vents & provide roof vent cap duplex sump pump."|"1"|"NAT_GAS"|"S"|"2003"|"13"|"4,000"|"Replace oil side of DHWH."|"1"|"S"|"1959"|"5"|"47,250"|"Replace original faucets & flushometers with touchless type, provide vacuum breaker on slop sinks, provide emergency eyewash on nurses sink."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2006"|"36"|"285,000"|"Replace 1 original boiler."|"1"|"S"|"2006"|"36"|"0"||"1"|"S"|"1990"|"10"|"269,000"|"A/C cafeteria, replace same window A/C units."|"1"|"S"|"1959"|"5"|"140,500"|"Refurbish CR UV's, gym H&V & faculty/music H&V, provide RA duct from kitche, replace damper UV grille, provide relief air path for rooms 16, 11, 12 & 33."|"1"|"S"|"1959"|"5"|"0"||"1"|"S"|"1959"|"5"|"0"||"1"|"S"|"1990"|"10"|"185,000"|"Provide energy management system, refurbish ATC system & tie exhaust to day/night system."|"1"|"S"|"1999"|"9"|"25,000"|"Tie kitchen Ansul system to FA & repair FA system."|"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1959"|"1959"|"0"||"1"|"S"|"1995"|"5"|"12,000"|"Provide additional emergency lighting in gym, cafeteria & 2nd & 3rd wing corridor, replace 3 fluorescent exit signs."|"1"|"S"|"1959"|"5"|"190,000"|"Replace & enlarge generator to handle more load."|"1"|"0"|"21,000"|"Need HC pushbutton operators on toilets."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"0"|"0"|"GOOD"||"4,515,450"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 1:25:04 PM| 679|"Randolph CSD"|"04300104"|"Elementary School"|"0002"|"05/18/2010"|"22 Elm Street"|"Randolph"|" 14772"|"ANNUAL"|"07/01/2011"|"1956"|"97,461"|"1"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"500"|"Pre-K,K,1,2,3,4,5,6"|"0"|"1"|"0"|"500"|"0"|"0"|||"23"|"20,700"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1978"|"15"|"0"||"1"|"S"|"1978"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2001"|"5"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"5"|"0"||"1"|"S"|"2001"|"5"|"0"||"1"|"S"|"2002"|"5"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"120,000"|"REplace ceilings at 1957 classroom wing."|"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"S"|"2002"|"20"|"10,000"|"Replace Kitchen/Cafeteria doors."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"70,000"|"Replace lighting at 1957 classroom wing."|"1"|"1"|"S"|"2001"|"5"|"42,000"|"Upgrades to security and LAN/WAN systems."|"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"5"|"45,000"|"Replace carpet in classrooms and Library."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"20"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"5"|"50,000"|"Masonry restoration."|"1"|"MASONRY"|"S"|"1956"|"15"|"0"||"1"|"MASONRY"|"S"|"2002"|"20"|"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"18,000"|"Replace doors at 1956 wing."|"1"|"S"|"2002"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"0"||"1"|"OTHER"|"S"|"2000"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1998"|"1"|"40,000"|"Replace pumps, balancing valves, frost-free hydrants."|"1"|"PVC"|"S"|"1998"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"1"|"80,000"|"Replace water heaters, mixing valves, pumps."|"1"|"S"|"2000"|"10"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"1996"|"5"|"500,000"|"Replace steam boilers with hot water boiler system."|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1998"|"8"|"35,000"|"Upgrade A/C and ventilation for Server Room and Data Closet."|"1"|"S"|"1998"|"20"|"15,000"|"Replace damper actuators at roof fans."|"1"|"S"|"1998"|"10"|"200,000"|"Replace original steam piping to classrooms."|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"10"|"125,000"|"Update pneumatic controls to DDC."|"1"|"S"|"2000"|"20"|"40,000"|"Extend audio visual signal to non-compliant areas."|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"100,000"|"Code required life safety and equipment circuit segregation."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,FIREALARM,LIGHTING"|"FULL"||"1"||"GOOD"||"1,490,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/29/2010 1:43:00 PM| 684|"Akron CSD"|"14210104"|"K-12 Main Building"|"0001"|"10/11/2010"|"47 BLOOMINGDALE AVE "|"AKRON "|" 14001"|"ANNUAL"|"07/01/2011"|"1928"|"404045"|"2"|"14"|"9"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"1614"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"1614"|"0"|"0"|||"130"|"140360"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,LIBBRARY,MUSIC,POOL"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"34"|"0"|"Adequate for current service level"|"1"|"MUN_UTILIT"|"E"|"2010"|"40"|"0"||"1"|"S"|"2010"|"40"|"0"|"Meter and regulators replaced 2010 service from street 1995"|"1"|"UTIL"|"BELOW"|"S"|"2001"|"20"|"0"||"1"|"S"|"2010"|"40"|"0"|"NW side of building replaced 2010 remainder of system vary but still function"|"1"|"S"|"2004"|"30"|"0"||"1"|"S"|"2010"|"30"|"0"|"NW side of building replaced 2010 remainder of structures in varying condition still functioning"|"1"|"S"|"2004"|"30"|"0"||"0"|||||||"0"||"0"||||"0"||"1"|"S"|"2004"|"30"|"0"||"0"||||"0"||"1"|"E"|"2010"|"40"|"0"||"1"|"ASPHALT"|"S"|"2010"|"5"|"85000"|"Athletic driveway edges starting to deteriorate"|"1"|"CONCRETE,ASPHALT"|"S"|"2010"|"20"|"30000"|"Miscellaneous areas of deteriorating slabs"|"1"|"S"|"2004"|"14"|"6000"|"Missing ground level event does not present hazard"|"1"|"S"|"2004"|"4"|"227000"|"N"|"Press box does not meet existing requirements several portable bleachers lack fall protection"|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2001"|"5"|"150000"|"High and Elementary School elevators are coming to the end of their useful life 2 of 4 elevators in school"|"1"|"1"|"E"|"2010"|"30"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"0"||"1"|"COMMON"|"S"|"2010"|"15"|"0"||"1"|"INSTRUCT"|"E"|"2010"|"20"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"20"|"0"|"Original gym floor joists show signs of rust no structural issues visible to be monitored"|"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"1"|"MASONRY"|"S"|"2010"|"30"|"0"||"1"|"MASONRY"|"S"|"2010"|"10"|"10000"|"Deterioration of stone masonry at front parapet of High School"|"S"|"S"|"0"|"1"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"60000"|"Several locations have handrails that do not conform to current standards"|"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"S"|"Y"|"2010"|"20"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"15"|"0"||"1"|"PLASTIC"|"S"|"2001"|"5"|"10000"|"Skylight over gym and girls locker room coming to end of useful life Skylight over gym cracked"|"1"|"GALVANIZED,COPPER"|"S"|"2010"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2010"|"20"|"75000"|"Sanitary sewer piping in Elementary School crawlspace is currently leaking and needs replacement High School grease trap too small"|"1"|"NAT_GAS"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"20"|"0"||"0"||"1"|"BOILERWATE,BOILERSTEA,FURNACE"||"S"|"2001"|"20"|"0"||"1"|"E"|"2010"|"30"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"25"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"E"|"2010"|"30"|"0"||"1"|"1"|"25000"|"Door clearance at two toilets by original gym"|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"1"|"1"|"0"|"1"|"COMMSYS,KITCHEN,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"678000"|"S"|"0"|"Wendel Duchscherer"|"140 John James Audubon Parkway Suite 201 Amherst NY 14228"|"7166880766"|"lniziol@wendelcompanies.com"|"Brian Brady"|"014519"|"I ACCEPT"|12/29/2010 2:22:21 PM| 685|"Plainview-Old Bethpage CSD"|"28050406"|"Pasadena Elementary School"|"0021"|"09/30/2010"|"PASADENA DR-RICHARD CT "|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1959"|"58086"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"400"|"1,2,3,4"|"0"|"0"|"0"|"400"|"0"|"0"|||"20"|"16,000"|"ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1995"|"35"|"12,500"|"Provide cage overfill alarm, remove sludge from tank & repair alarm condition."|"1"|"MUN_UTILIT"|"S"|"1959"|"5"|"96,000"|"Provide additional site fire hydrants."|"1"|"MUN_UTILIT"|"S"|"1995"|"35"|"0"||"1"|"S"|"1990"|"30"|"4,000"|"Repair gas line supports on roof."|"1"|"UTIL"|"BELOW"|"S"|"1959"|"5"|"0"||"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1959"|"10"|"20,000"|"Add drainage in SE lot."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1959"|"5"|"285,000"|"Repave all except south lot - crackfill & seal."|"1"|"CONCRETE,ASPHALT"|"S"|"1959"|"5"|"29,500"|"Replace west side asphalt walk, baseball walk, and approx. 10 sections concrete sidewalk. Repitch sidewalk at cafeteria addition due to flooding under door."|"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"1959"|"10"|"27,000"|"N"|"Replace timber retaining wall at RPZ. Crackfill & seal asphalt play area. Close off fence by library & north end driveway."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1959"|"15"|"0"||"1"|"S"|"1959"|"15"|"0"||"1"|"S"|"1959"|"15"|"42,000"|"Replace toilet partitions."|"1"|"S"|"1959"|"10"|"75,000"|"Repair plaster & repaint 3 toilet room ceilings & vestibules."|"0"||||"0"||"1"|"S"|"S"|"1959"|"10"|"7,500"|"Add closer on kitchen doors & other misc. hardware replacements."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"40"|"102,500"|"Provide electric hand dryers, provide 12 additional circuits for A/Cs, provide additional outlets in CRs, nurses office, APs office & front hall & replace missing GFI cover, replace Frank Adams CB panels (4)."|"1"|"S"|"2000"|"15"|"52,500"|"Provide additional site lighting (6), replace 6 missing lenses & replace stage dimmer, clean/repair/replace exterior lighting fixtures."|"1"|"1"|"S"|"2000"|"15"|"556,000"|"Provide data upgrades, IP telephones, provide additional PA speakers, provide exterior PA speakers by field, replace gym & cafeteria sound systems."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1959"|"5"|"4,000"|"Replace carpet in choral room."|"1"|"INSTRUCT,COMMON"|"S"|"1959"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1959"|"10"|"32,000"|"Replace ceramic floor tile at 6 toilet rooms."|"1"|"COMMON"|"S"|"1959"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1959"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1959"|"15"|"145,000"|"Paint canopy stanchions (incl minor conc work).Rpr cracks S mech.rm brick.Various areas of re-pt incl N lines@1st flr end walls and mech rm walls.Rpr lintel lines&step cracks outside BR.Rebld corner over BR.Elastcoating on entire bldg."|"1"|"MASONRY"|"S"|"1959"|"15"|"7,500"|"Minor masonry repair, repair metal cap."|"1"|"MASONRY"|"S"|"1959"|"10"|"0"||"U"|"S"|"0"|"1"|"1959"|"5"|"9,200"|"Replace all exterior doors & frames. Repair concrete landings at saddles. Replace aluminum door at library story area."|"1"|"S"|"1959"|"15"|"5,000"|"Paint all exterior railings."|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1959"|"5"|"1,350,000"|"Replace all original building windows (green panels reported to be transite)."|"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"5"|"62,000"|"Paint steel roof edges. Install missing section of aluminum fascia west side. Replace all skylights."|"1"|"PLASTIC"|"U"|"1959"|"5"|"0"|"Replace all skylights."|"1"|"COPPER"|"S"|"2000"|"40"|"30,000"|"Replace 4 hose faucets, provide emergency shower, provide emergency gas shutoff in kitchen BR areas."|"1"|"IRON"|"S"|"1959"|"5"|"26,000"|"Clear vents & provide roof plumbing vent caps, provide duplex sump pump."|"1"|"NAT_GAS"|"S"|"1990"|"5"|"27,000"|"Replace water heater & provide Summer bypass system."|"1"|"S"|"1990"|"30"|"42,250"|"Replace faucets/flushometers, provide vacuum breakers on slop sinks, provide emergency eyewash station in custodial area."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1959"|"5"|"285,000"|"Replace original boiler."|"1"|"S"|"1959"|"5"|"0"||"1"|"S"|"1995"|"5"|"385,000"|"A/C cafeteria/kitchen area."|"1"|"S"|"1959"|"5"|"203,000"|"Provide FAI for 6 rms, repl 6 damaged UV grilles,return for kitchen unit,provide UVs for Kind rm to repl H&V units, add FC unit to Kind hall,add exh to B&G BRs by gym & provide ventilation for 2 copy areas."|"1"|"S"|"1959"|"5"|"81,500"|"Repair leaks at heat exchangers, replace steam traps."|"1"|"S"|"1959"|"5"|"0"||"1"|"S"|"2000"|"10"|"193,000"|"Provide energy management system, refurbish ATC system, tie units to day/night system, repair exhaust fan pnuematic dampers."|"1"|"S"|"2000"|"10"|"17,000"|"Repair FA system, tie kitchen hood in FA system."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1959"|"1959"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"|"E"|||"0"||"1"|"1"|"21,000"|"Need HC pushbuttons on toilets."|"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"1"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"|"0"|"1"|"0"|"GOOD"||"4,234,950"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 2:27:57 PM| 686|"East Syracuse-Minoa CSD"|"42040106"|"Woodland Elementary"|"0024"|"08/31/2010"|"FREMONT RD "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/2010"|"1968"|"59,641"|"1"|"2"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"355"|"K,1,2,3,4,5"|"0"|"1"|"1"|"355"|"0"|"0"|||"22"|"17,600"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"|"Shared with Pine Grove"|"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"S"|"2003"|"35"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2009"|"25"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"U"|"1968"|"5"|"9000"|"Replace broken catch basin by soccer field."|"1"|"S"|"2006"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"20"|"0"||"1"|"CONCRETE"|"E"|"2009"|"20"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"10"|"1000"|"Recommend repairing crack @ west wall of Gym."|"1"|"S"|"1968"|"40"|"0"|"Recommend enclosing classrooms - issues with acoustics. (future)"|"1"|"U"|"2003"|"5"|"71,000"|"Recommend replacing ceiling tile in corridors."|"0"||||"0"||"1"|"S"|"S"|"2009"|"30"|"9,000"|"Recommend replacing non-complaint door hardware (10 doors)."|"1"|"S"|"1968"|"35"|"0"||"0"||||"0"||"1"|"1"|"U"|"1969"|"5"|"105,000"|"Recommend replacing original 277/480V service feeders and switchboard"|"1"|"S"|"2009"|"15"|"26,000"|"Recommend adding occupancy sensors, 10-12 classrooms."|"1"|"1"|"E"|"2009"|"30"|"0"|"Telephone upgrades; Intrusion Detection System & CCTV installed w/ "Safe + Sound" project."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"15"|"0"||"1"|"COMMON"|"S"|"1968"|"10"|"0"||"1"|"COMMON"|"S"|"1968"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"|"Stepped crack at west wall of Gym"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"40"|"2000"|"Recommend repairing stepped crack at west wall of Gym"|"1"|"METAL"|"E"|"2003"|"20"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"20"|"0"|"Replaced w/ "Safe + Sound" project."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2005"|"25"|"0"|"Replaced w/ "Safe + Sound" project."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Replaced w/ "Safe + Sound" project. "|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2003"|"10"|"14000"|"Recommend labeling all hot, cold, & domestic water lines including shut-offs. "|"1"|"IRON,COPPER"|"S"|"1968"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"10"|"0"||"1"|"U"|"2009"|"5"|"253,000"|"Recommend replacing original 1968 fixtures with water conserving fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"35"|"0"||"1"|"S"|"2003"|"25"|"0"|"Building unit ventilators have air conditioning"|"1"|"S"|"2003"|"25"|"21,000"|"Roof top units serving interior zones have leaking door seals (water infiltration)"|"1"|"S"|"2003"|"35"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"U"|"2000"|"5"|"131,000"|"Recommend replacing Simplex 4002 w/ point addressable system; Add classroom strobes."|"1"|"U"|"2000"|"5"|"30,000"|"Recommend replacing devices with point addressable type."|"0"||||"0"||"1"|"E"|"2009"|"30"|"0"|"Upgraded w/ "Safe + Sound" project."|"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"POOR"|"There are acoustical issues with open plan classroom layout."|"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"POOR"|"Open plan design not desired-recommend enclosing classrooms"|"672,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"3156826180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/29/2010 2:32:08 PM| 687|"Three Village CSD"|"58020106"|"Minnesauke School"|"0014"|"8/3/10"|"21 Highgate Drive"|"East Setauket"|" 11733"|"ANNUAL"|"5/1/11"|"1968"|"105,850"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"805"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"805"|"0"|"0"|||"47"|"37,600"|"ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,TEACHRSRC"||"1"|"0"|"0"|"1"|"12,000"|"S"|"1995"|"5"|"0"|"Double wall fiberglass"|"1"|"MUN_UTILIT"|"S"|"2003"|"15"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2003"|"15"|"32,000"|"Relocate existing pad mounted transformer. Test main service & distribution equipment infrared tested for "hot spots", clean & tighten connections, lubricate & operate all devices as preventative maintenance"|"1"|"E"|"2010"|"25"|"0"||"0"||||"0"||"1"|"E"|"2010"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"25"|"98,000"|"Replace asphalt around portables & behind building"|"1"|"CONCRETE"|"E"|"2010"|"20"|"40,000"|"Recommend replacement of concrete behind gym/cafeteria"|"1"|"E"|"2007"|"15"|"0"||"1"|"S"|"2006"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"28,000"|"No fire rating on pass-thru display case Art Rm. Upper storage rms to be cleaned out due to lack of fire separaration from adj Auditorium. Extend walls surrounding Projection Rm storage up to roof deck & install ceiling & lighting assembly."|"1"|"S"|"2003"|"25"|"32,000"|"Monitor masonry cracks adj to Rm 500. Cracks along walls that divide Rms 205 & 203 should be cleaned out & filled with non-shrink grout. Crack within Boiler Rm & along ext wall of Cust Office require attention"|"1"|"S"|"2010"|"20"|"630,000"|"Recommend replacement of original 2 x 4 dropped ceilings in classrooms, offices & Cafeteria"|"1"|"S"|"1968"|"15"|"0"||"1"|"S"|"S"|"2006"|"15"|"208,200"|"Remove all door stops, install hold open devices,long range int door replacement, replace knobs with lever type hardware, install fire rated doors where required"|"1"|"S"|"1968"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"15"|"24,000"|"Furnish & install new panel boards at sub-panels to provide spare circuits in all areas of the school. Electrical outlets in Cafeteria wing not functioning."|"1"|"S"|"2009"|"15"|"0"||"1"|"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2010"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"325,000"|"Cost to replace remaining VAT"|"1"|"INSTRUCT"|"S"|"1968"|"25"|"0"||"1"|"INSTRUCT"|"S"|"1968"|"15"|"10,000"|"Termite damage noted on stage floor & wood base"|"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"25"|"0.00"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2003"|"25"|"42,000"|"Ext masonry reconstruction & misc steel lintel replacement is required - outside Rm 101, external corner of gym, wiring wall by kitchen receiving area, existing chimney & outside Rm 210 - around fresh air intake grills as needed"|"1"|"MASONRY"|"S"|"1968"|"5"|"0"|"Repointing required"|"0"|||||"0"||"S"|"S"|"1"|"1"|"2003"|"20"|"15,000"|"Replace lower level Boiler Rm door & custodial office overhead door"|"1"|"S"|"2003"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"10"|"42,000"|"Multiple windows require counterbalance replacement. Replace upper & lower raised colonial panels at ext window units adj to custodial entrance. Long range plan to replace windows."|"OTHER"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2003"|"30"|"0.00"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"15"|"0"|"Pipes leaking above plaster ceiling in Girls' Locker Room"|"1"|"IRON"|"S"|"2010"|"20"|"0"|"Bathroom & Nurse's Office renovation"|"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"|"Partial replacement - Nurse's Office, classroom sinks & 1 ADA toilet (men's & women's)"|"0"||"1"|"BOILERWATE"||"S"|"2003"|"5"|"325,000"||"1"|"S"|"2003"|"5"|"325,000"||"1"|"S"|"2003"|"20"|"0"||"1"|"U"|"1968"|"2"|"40,000"|"Office area A/C units. 4 perimeter terminal air conditioning (PTAC) units which provide air conditioning to several office areas are in need of replacement"|"1"|"S"|"2003"|"20"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2000"|"2000"|"0"|"Inspection on a yearly basis"|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"1"||"Recommend renovation to boys' & girls' multi stall toilets in 200 Wing"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"LIGHTING"|"WARMING"||"1"||"GOOD"||"2,216,200"|"U"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/29/2010 2:50:26 PM| 689|"Chittenango CSD"|"25160106"|"Bridgeport Elementary"|"0004"|"06/29/2010"|"9076 North Road"|"Chittenango"|" 13030"|"ANNUAL"|"09/01/2011"|"1952"|"60,062"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"267"|"K,1,2,3,4,5"|"0"|"0"|"1"|"267"|"0"|"0"|||"15"|"11586"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1973"|"20"|"0"||"1"|"SITESEPT"|"S"|"1973"|"5"|"80,000"|"Provide raised bed system."|"1"|"S"|"1973"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1996"|"26"|"55,000"|"Provide new bus loop pole mount lighting."|"0"||||"0"||"1"|"U"|"1973"|"10"|"2,000"|"Remove debris and redefine drainage culverts to allow for storm water drainage adjacent to Shackelton Point."|"0"||||"0"||"1"|"U"|"1973"|"10"|"1,000"|"Remove debris from pipe and ends to allow for storm water drainage adjacen to Shackelton Point."|"0"|||||||"0"||"0"||||"0"||"0"||||"18,000"|"It is recommended that a retention basin be constructed in lawn area adjacent to North Road to provide an area for storm water collection of the west parking area and bus loop to alleviate flooding."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"15"|"165,000"|"Provide separation of student and bus traffic with redesigning bus loop and parking area including new raised walk, concrete curbs and asphalt bus loop and parking area. 29,600 SF"|"1"|"ASPHALT"|"U"|"1973"|"10"|"21,000"|"Asphalt walk should be removed due to sub-surface failure and replaced with 10 ft wide concrete walk (1,400 SF)."|"1"|"U"|"2003"|"15"|"6,000"|"Add 6 inch of engineered wood fiber to entire play area (143 CY)."|"1"|"U"|"1973"|"5"|"8,000"|"N"|"Remove and replace chain link backstop and footings."|"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"S"|"2000"|"55"|"14,000"|"Need to infill/seal the old vent opening below a door on the south wall of the building where water is entering crawlspace. Repair rusted bases of steel columns with plates."|"1"|"S"|"2000"|"40"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2009"|"10"|"35,000"|"Install new suspended ceiling tile in cafeteria. Tiles in classrooms should be replaced."|"0"||||"0"||"1"|"S"|"S"|"2000"|"15"|"20,000"|"A number of classroom doors need closers and lever hardware."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1996"|"15"|"97,000"|"Replace Panels L9, L11, L12, L13. Add convenience receptacles. Replace stage dimming system."|"1"|"S"|"1996"|"15"|"85,000"|"Replace crawlspace lighting, exterior lighting, gym lighting, and incandescent lighting. Add occupancy sensors."|"1"|"1"|"S"|"1996"|"0"|"89,000"|"Replace intercom/public address system. Replace gymnasium PA system."|"0"||||"0"||"1"|"INSTRUCT"|"E"|"2010"|"20"|"15,000"|"Carpeting in main office and library should be replaced in the next 5 years."|"1"|"INSTRUCT,COMMON"|"E"|"2009"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2005"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"40"|"4,000"|"Corrosion on a couple of beams in crawlspace."|"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2000"|"35"|"88,000"|"Replace and repoint brick along east side of building, including brick ties. Replace lintel at west cafeteria entrance."|"1"|"MASONRY"|"S"|"1973"|"25"|"18,000"|"Route out cracks and seal/repoint/remove efflourescence."|"1"|"MASONRY"|"S"|"1973"|"25"|"0"||"E"|"E"|"1"|"1"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2010"|"10"|"150,000"|"Replace remaining slider units."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"5"|"110,000"|"Replace upper gym roof in the next 5 to 7 years."|"1"|"PLASTIC"|"S"|"2000"|"5"|"0"||"1"|"COPPER"|"S"|"1991"|"5"|"31,500"|"Replace 4 inch service piping, cut pipe samples for testing, insulate crawlspace piping, replace valves, add backflow preventer."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1991"|"5"|"30,000"|"Add plaster traps, backwater valves and sump pumps."|"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"1991"|"12"|"88,800"|"Add kitchen hand sink, replace nurse's sink faucet, classroom sinks, mop sink faucets and outdated fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2006"|"26"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||||"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"2005"|"0"||"1"|"S"|"1996"|"10"|"53,000"|"Replace exit and emergency lighting and circuitry."|"1"|"S"|"1996"|"5"|"50,000"|"Provide new NFPA Level 1 generator and distribution."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,630,590"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/29/2010 2:55:40 PM| 690|"Commack USFD"|"58041003"|"WOOD PARK PRIMARY SCHOOL"|"0009"|"02/17/2010"|"NEW HIGHWAY "|"COMMACK "|" 11725"|"ANNUAL"|"05/01/2011"|"1961"|"75666"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"467"|"K,1,2"|"0"|"1"|"1"|"467"|"0"|"0"|||"34"|"27136"|"ADMIN,ART,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED,OTHER"|"Cafetorium"|"1"|"0"|"0"|"1"|"10000"|"U"|"1990"|"1"|"80000"|"Replace and relocate tank."|"1"|"MUN_UTILIT"|"S"|"2006"|"15"|"0"||"1"|"SITESEPT"|"S"|"2006"|"15"|"0"||"1"|"S"|"2001"|"40"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2006"|"15"|"0"||"1"|"S"|"1961"|"5"|"0"||"0"||||"0"||"1"|"S"|"1961"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"10"|"0"||"1"|"CONCRETE"|"S"|"2008"|"15"|"0"||"1"|"S"|"2000"|"25"|"0"||"0"|"U"|"1961"|"1"|"15000"|"N"|"Replace chain link fence around tennis courts."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1961"|"15"|"0"||"1"|"S"|"1961"|"25"|"0"||"1"|"S"|"1961"|"25"|"0"||"1"|"U"|"1961"|"1"|"150000"|"Replace old acoustic tile ceilings."|"0"||||"0"||"1"|"S"|"S"|"1961"|"5"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2004"|"5"|"0"||"1"|"U"|"1961"|"1"|"0"|"Replace original fixtures in corridors."|"1"|"1"|"S"|"2004"|"5"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"5"|"0"||"1"|"COMMON"|"S"|"2004"|"5"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1961"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1961"|"5"|"0"||"1"|"MASONRY"|"U"|"1961"|"1"|"40000"|"Chimney needs repointing, replacing of some bricks and flashing at base."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1995"|"15"|"0"||"1"|"S"|"1961"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"17"|"0"||"WOODONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"12"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2004"|"15"|"0"||"1"|"IRON"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"U"|"1961"|"1"|"50000"|"Replace original fixtures as required."|"0"||"1"|"BOILERWATE"||"S"|"1990"|"20"|"0"||"1"|"S"|"1991"|"30"|"0"||"1"|"S"|"1998"|"37"|"0"||"1"|"U"|"1961"|"1"|"80000"|"Repair or replace rooftop fans and Cafeteria air handling units."|"1"|"U"|"1961"|"1"|"350000"|"Replace unit ventilators and pumps."|"1"|"U"|"1961"|"1"|"10000"|"Ducts require cleaning."|"1"|"S"|"2004"|"18"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||||"0"||"1"|"U"|"2004"|"1"|"5000"|"Replacement of the incandescent exit signs is recommended."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"POOR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"$ 790,000"|"U"|"1"|"Tagi A. Garbizu Associates"|"501 Route 111, Hauppauge, NY 11788"|"631-979-9397"|"tgarbizu@optonline.net"|"Tagi Garbizu"|"012741"|"I accept"|12/29/2010 2:57:45 PM| 691|"Oneida City SD"|"25140001"|"Power Shop Annex"|"0007"|"09/02/2010"|"565 Sayles Street "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1971"|"5800"|"1"|"0"|"0"|"DISTRICT"|"INSTRUCT"||"20"|"9,10,11,12"|"0"|"0"|"1"|"20"|"0"|"0"|||"1"|"600"|"AV,OTHER"|"TV Studio"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"|"Service from H.S."|"1"|"MUN_UTILIT"|"S"|"2003"|"25"|"0"||"1"|"S"|"2003"|"25"|"0"|"Service from H.S."|"1"|"UTIL"|"BELOW"|"S"|"2003"|"30"|"0"|"Fed from H.S."|"1"|"S"|"2003"|"25"|"0"|"Infrastructure ties into HS System"|"0"||||"0"||"1"|"S"|"2009"|"25"|"0"|"Structures re-built w/ EXCEL funds"|"0"||||"0"||"0"|"SURFACEH2O"|"Higinbotham Brook"|"1"||||"0"|"Infrastructure ties into HS system, which discharges to Higinbotham Brook"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"30"|"0"|"Paved gravel parking lot w/ EXCEL & replaced retaining wall"|"1"|"ASPHALT"|"S"|"2004"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"20"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 - district wide VoIP telephone system"|"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"|"@ office"|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"|"ceramic tile @ toilet room"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"15"|"0"||"1"|"METAL"|"S"|"2003"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"5"|"3,000"|"Recommend replacing (1) exterior door/frame/hardware (corroded)"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"NA"|"2004"|"15"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Replaced rood w/ EXCEL funds"|"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"25"|"0"||"1"|"ELECTRIC"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2003"|"15"|"0"|"Ground mounted gas-fired RTU for TV Studio & adjacent spaces."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"GOOD"||"3,000"|"S"|"1"|"King + King Architects LLP"|"358 West Jefferson Street, Syracuse, NY 13209"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/29/2010 3:04:07 PM| 692|"BOCES Cayuga-Onondaga"|"05900000"|"REGIONAL EDUCATION CTR."|"0023"|"11/9/10"|"1879 West Genesee St. Road "|"Auburn"|"13021"|"ANNUAL"|"9/1/2011"|"2007"|"201968"|"2"|"13"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER,OTHER_ORG"|"Day Care, Copy Center, Library System, AV Repair"|"614"|"Pre-K,9,10,11,12,OTHER"|"0"|"1"|"0"|"614"|"0"|"0"|||"46"|"38191"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,PREK,SPECED,TECHSHOP,OTHER"|"Greenhouse"|"1"|"1"|"300"|"0"|"0"|"S"|"2004"|"8"|"0"||"1"|"MUN_UTILIT"|"S"|"2007"|"23"|"0"||"1"|"MUN_UTILIT"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2007"|"23"|"0"||"0"||||"0"||"1"|"S"|"2007"|"23"|"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT,OTHER"|"S"|"2007"|"8"|"0"||"1"|"CONCRETE"|"S"|"2007"|"18"|"0"||"1"|"S"|"2009"|"14"|"0"|"Two original playgrounds were installed in 2007. An additional playground was installed in 2009 for special education program."|"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2007"|"48"|"0"||"1"|"S"|"2007"|"48"|"0"||"1"|"S"|"2007"|"48"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"48"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"18"|"0"||"1"|"1"|"S"|"2007"|"18"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"9"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"23"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"23"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2007"|"48"|"0"||"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"48"|"0"||"1"|"METAL"|"S"|"2007"|"23"|"0"||"1"|"MASONRY,OTHER"|"S"|"2007"|"48"|"0"||"S"|"S"|"0"|"1"|"2007"|"13"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2007"|"18"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"23"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2007"|"23"|"0"||"1"|"IRON,COPPER"|"S"|"2007"|"23"|"0"||"1"|"NAT_GAS"|"S"|"2007"|"13"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"DD_MZ"|"1"|"BOILERWATE,GEOTHERMAL"||"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"S"|"2007"|"23"|"209000"|"Add cooling of gymnasium space for special education and other programs. Included are associated costs required within items 78 thru 81 below."|"1"|"S"|"2007"|"23"|"0"|"See number 77F comment above. "|"1"|"S"|"2007"|"23"|"0"|"See number 77F comment above."|"1"|"S"|"2007"|"23"|"0"|"See number 77F comment above. "|"1"|"S"|"2007"|"13"|"22000"|"See number 77F comment above. Also $22000 estimated cost figure is to upgrade technology program."|"1"|"S"|"2007"|"13"|"0"||"1"|"S"|"2007"|"13"|"0"||"1"|"S"|"2007"|"2007"|"0"||"1"|"S"|"2007"|"13"|"0"||"1"|"S"|"2007"|"23"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,FIREALARM,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"231000"|"S"|"1"|"Samuel J. Cichello, Architect"|"2714 Franklin St, Weedsport, NY 13166"|"315-689-7090"|"sjcarch@gmail.com"|"Samuel J. Cichello"|"007611"|"I ACCEPT"|12/29/2010 3:05:27 PM| 695|"Kenmore-Tonawanda UFSD"|"14260103"|"A. Hamilton Elementary School"|"0005"|"10/07/2010"|"44 WEST FALL DRIVE "|"TONAWANDA "|" 14150"|"ANNUAL"|"10/07/2010"|"1958"|"78,880"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"372"|"Pre-K,K,1,2,3,4,5"|"0"|"0"|"0"|"372"|"0"|"0"|||"16"|"12800"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"8,000"|"U"|"1969"|"1"|"135,000"|"REMOVE UNDERGROUND TANK, EQUIPMENT, PIPING, ACCESSORIES AND EST. 475 CU.YDS. OF CONTAMINATED SOIL."|"1"|"MUN_UTILIT"|"S"|"1969"|"1"|"127,000"|"BACKFLOW PREVENTER AND EXTERIOR ENCLOSURE FOR DOMESTIC WATER AND ATHELETIC FIELD."|"1"|"MUN_UTILIT"|"S"|"1969"|"15"|"0"||"1"|"S"|"1969"|"1"|"6,000"|"INSTALL FENCE AROUND GAS METER SETTING"|"1"|"UTIL"|"BELOW"|"S"|"2002"|"20"|"0"||"1"|"S"|"1969"|"5"|"50,000"|"REPLACE DETERIORATED SECTIONS OF STORM PIPING. REPLACE DAMAGED ROOF DRAIN PIPING."|"0"||||"0"||"1"|"S"|"1983"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1983"|"5"|"320,000"|"RECONSTRUCT EXISTING ASPHALT DRIVE AND PARKING LOT."|"1"|"CONCRETE"|"S"|"1983"|"5"|"55,000"|"REPLACE DETERIORATED CONCRETE SIDEWALKS AND CURBS."|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"1983"|"4"|"25,000"|"N"|"REGRADE AND SEED ATHLETIC FIELD."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1961"|"20"|"0"||"1"|"S"|"1961"|"20"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"3"|"40,000"|"REPLACE CORRIDOR CEILINGS AND CEILING IN LIBRARY."|"1"|"S"|"1983"|"7"|"0"||"1"|"S"|"S"|"1983"|"3"|"50,000"|"REPLACE HARDWARE WITH LEVER LOCKSETS AND REPLACE MISC. INTERIOR DOORS."|"1"|"S"|"1961"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"0"|"253,000"|"PROVIDE GFCI RECEPTICLES, REPLACE OLD WIRING AND OLDER VINTAGE PANEL BOARDS."|"1"|"S"|"2002"|"5"|"165,000"|"REPLACE THEATRICAL AND HOUSE LIGHTING IN AUDITORIUM AND VARIOUS INTERIOR AND EXTERIOR FIXTURES."|"1"|"1"|"S"|"2003"|"1"|"188,000"|"REPLACE CLOCK SYSTEM, REPLACE AUDITORIUM SOUND SYSTEM, LOWER TELEPHONE SETS TO MEET ADA CODES."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1983"|"3"|"8,000"|"REPLACE CARPET IN THE LIBRARY AND MISC. OFFICES."|"1"|"INSTRUCT"|"S"|"1983"|"7"|"0"||"1"|"COMMON"|"S"|"1983"|"3"|"50,000"|"REPLACE CERAMIC TILE FLOORS AND QUARRY TILE FLOORS IN KITCHEN AND LOCKER AREAS."|"1"|"INSTRUCT"|"S"|"1983"|"7"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"NONE"|"1"|"1"|"0"|"S"|"1961"|"1"|"10,000"|"REPLACE CONCRETE FLOOR SLAB IN KINDERGARDEN ROOM, EXISTING SLAB SETTLED AND LOWERED AT EXTERIOR WALL."|"MASONRY,STEEL"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2004"|"20"|"0"||"1"|"MASONRY"|"S"|"1983"|"7"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2000"|"5"|"100,000"|"REPLACE EXTERIOR DOORS AND REPLACE SECURITY SYSTEM MOTION SENSORS."|"1"|"S"|"1983"|"3"|"75,000"|"REPLACE EXISTING CONCRETE STAIRS AND INSTALL NEW ADA RAMPS AT 3 ENTRANCES."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"20"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"|"NONE"|"S"|"2006"|"21"|"0"||"0"|||||"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1969"|"1"|"6,000"|"INSTALL BACKFLOW PREVENTER ON BOILER- MAKE-UP WATER."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1969"|"1"|"80,000"|"KITCHEN PLUMBING UPGRADES INCLUDING REPLACEMENT OF GREASETRAP."|"1"|"NAT_GAS"|"S"|"1969"|"3"|"92,000"|"REPLACE HOT WATER HEATERS, PIPING, STORAGE TANK AND ACCESSORIES."|"1"|"S"|"2004"|"1"|"150,000"|"REPLACE CORRIDOR DRINKING FOUNTAINS WITH ADA ELECTRIC WATER COOLERS, HOSE BIBB FOR GANG LAVS, REPLACE CLASSROOM SINKS, REPLACE WALL HYDRANT WITH NON-FREEZE VACUUM BREAKER TYPE."|"0"||"1"|"BOILERWATE"||"S"|"1969"|"3"|"380,000"|"REPLACE BOILERS AND ACCESSORIES."|"1"|"S"|"1969"|"6"|"0"||"1"|"S"|"1969"|"10"|"0"||"1"|"U"|"1969"|"1"|"1,130,000"|"REPLACE UNIT VENTS, EXHAUST FANS, AND RELIEF HOODS. ADD VENTILATION FOR DATA CLOSETS."|"1"|"S"|"1969"|"1"|"110,000"|"REPLACE VALVES AND PIPING FOR UNIT VENTS AND AIR HANDLING UNITS."|"1"|"S"|"1969"|"3"|"60,000"|"INTERNALLY CLEAN DUCTWORK."|"1"|"S"|"2003"|"5"|"210,000"|"UPDATE CONTROLS WITH NEW EQUIPMENT."|"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION SIGNALS."|"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED INITIATION DEVICESD FOR SMOKE DETECTION."|"1"|"S"|"2002"|"2002"|"253,000"|"RECONSTRUCTION WORK AT STAGE, INSTALL SPRINKLER SYSTEM FOR STAGE."|"1"|"S"|"2002"|"0"|"50,000"|"PROVIDE ADDITIONAL EXIT SIGNAGE, INTERIOR AND EXTERIOR EMERGENCY LIGHTING."|"1"|"U"|"1959"|"0"|"160,000"|"REPLACE EMERGENCY GENERATOR AND DISTRIBUTION SYSTEM."|"1"|"0"|"50,000"|"PROVIDE ADA ACCESSIBILITY IN THE LOCKER ROOMS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"0"|"1"|"FAIR"||"5,475,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN ST WILLIAMSVILLE, NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/29/2010 3:17:38 PM| 696|"Alexandria CSD"|"22020204"|"Bus Garage"|"0004"|"08/30/2010"|"34 BOLTON AVENUE "|"ALEXANDRIA BAY "|" 13607-1699"|"ANNUAL"|"07/01/2011"|"1969"|"8920"|"1"|"4"|"0"|"DISTRICT"|"INSTRUCT,OTHER"|"Bus Garage/Agriculture Classroom"|"20"|"9,10,11,12"|"0"|"0"|"1"|"20"|"0"|"0"|||"1"|"550"|"OTHER"|"Bus Maintenance and Agriculture Classroom"|"1"|"1"|"1000"|"2"|"6000"|"S"|"2001"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1969"|"5"|"88000"|"Upgrade and replace existing main disconnect switch and distribution panel"|"1"|"S"|"1969"|"10"|"0"|"Original construction"|"0"||||"0"||"1"|"U"|"2009"|"5"|"13000"|"Original storm structures are built up and need to be replaced with precast. Trench drain at overhead doors to repair bays needs to be reconstructed. "|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2009"|"30"|"0"|"Precast concrete drywell constructed to receive greenhouse drainage"|"1"|"ASPHALT"|"S"|"2001"|"10"|"0"||"1"|"CONCRETE"|"E"|"2009"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1969"|"30"|"0"||"1"|"U"|"1969"|"20"|"8000"|"Extend boiler room walls to deck"|"1"|"S"|"1969"|"20"|"0"||"1"|"U"|"1969"|"5"|"11000"|"Replace ACT - exceeded it useful life"|"1"|"U"|"1969"|"5"|"5000"|"Replace original lockers with ADA compliant lockers"|"1"|"U"|"U"|"1969"|"5"|"42000"|"Replace interior doors and door hardware"|"0"||||"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"1"|"S"|"1969"|"5"|"131000"|"Replace existing panelboards and associated branch circuits"|"1"|"S"|"1995"|"5"|"87000"|"Replace existing original fixtures and add auto controls throughout"|"1"|"1"|"S"|"1992"|"5"|"132000"|"Upgrade/replace existing data and telephone connectivity to main building"|"0"||||"0"||"1"|"INSTRUCT"|"U"|"1969"|"0"|"2000"|"Remove original carpet"|"1"|"INSTRUCT,COMMON"|"U"|"1969"|"5"|"14000"|"Replace original flooring, remove VAT in classroom under carpet"|"1"|"INSTRUCT,COMMON"|"S"|"1969"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1969"|"25"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1969"|"10"|"0"|"Repainting recommended"|"1"|"METAL"|"S"|"2008"|"15"|"0"||"0"|||||"0"||"U"|"U"|"0"|"1"|"1969"|"5"|"16000"|"Replace original doors that have exceeded their life expectancy"|"1"|"E"|"2009"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"NA"|"1969"|"0"|"19000"|"Replace original single pane windows"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"S"|"2008"|"15"|"0"|"Plugged drain pipe on lower roof, south side"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1969"|"5"|"44000"||"1"|"IRON"|"S"|"1969"|"10"|"0"||"1"|"OIL"|"S"|"2005"|"5"|"14000"||"1"|"S"|"1969"|"5"|"35000"|"Provide hard piped emergency eyewash, replace all fixtures"|"0"||"1"|"BOILERWATE"||"U"|"1969"|"0"|"80000"|"Replace boiler, add combustion air path"|"0"|"S"||"0"|"0"||"0"||||"0"||"1"|"U"|"1969"|"0"|"49000"|"Replace various fans, add unit ventilators for AG classroom"|"1"|"U"|"1969"|"0"|"82000"|"Replace hot water piping"|"1"|"S"|"1969"|"10"|"0"||"1"|"S"|"1969"|"0"|"97000"|"Upgrade controls to DDC, increase level of control"|"1"|"S"|"2010"|"5"|"26000"|"Upgrade detectors to addressable type."|"1"|"S"|"1987"|"5"|"26000"|"Replace existing devices with addressable type."|"1"|"S"|"1987"|"1987"|"0"||"1"|"S"|"1995"|"5"|"27000"|"Replace existing emergency battery units"|"1"|"S"|"2008"|"15"|"0"||"1"|"0"|"154000"|"Renovate toilet rooms, locker room for accessibility"|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"|"Add multi-level and automatic controls"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"POOR"|"Not enough storage space for buses, tools, or parts"|"1202000"|"U"|"1"|"King + King Architects"|"358 W. Jefferson St., Syracuse, NY 13202"|"315-682-6180"|"ktarolli@kingarch.com"|"James R. King"|"15925"|"I ACCEPT"|12/29/2010 3:37:40 PM| 698|"Brockport CSD"|"26180106"|"Bus Garage / CEPACS"|"5003"|"06/28/2010"|"40 ALLEN ST BLDG 800 "|"BROCKPORT "|" 14420"|"ANNUAL"|"09/01/2011"|"1957"|"16,450"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN,OTHER"|"Transportation office, buss maintenance, CEPACS (communications, electronics, printing, audio-visual, computers)"|"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"2"|"15,000"|"S"|"2006"|"26"|"0"|"10,000 gal. diesel and 5,000 gal gasoline"|"1"|"MUN_UTILIT"|"S"|"2006"|"46"|"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"46"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"|"Provide new service with building conversion"|"1"|"S"|"1990"|"30"|"0"|"Replace with ne site development at building"|"0"||||"0"||"1"|"S"|"2008"|"38"|"0"|"Replace with new site development at building"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1990"|"5"|"0"|"Replace with ne site development at building"|"0"|||||"0"|"no sidewalks"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"22"|"0"||"0"||||"0"|"No bearing or fire walls"|"1"|"S"|"1957"|"3"|"0"|"Replace as necessary for conversion"|"1"|"S"|"1990"|"15"|"0"|"Replace with conversion of building"|"0"||||"0"|"No lockers"|"1"|"S"|"S"|"1957"|"3"|"0"|"Replace with conversion of building"|"0"||||"0"||"1"|"S"|"1957"|"3"|"0"|"Remove lifts with conversion of building"|"1"|"1"|"S"|"1993"|"23"|"0"|"Replace with conversion of building"|"1"|"S"|"1993"|"3"|"0"|"Replace with conversion of building"|"1"|"1"|"S"|"2000"|"10"|"0"|"Replace with conversion of building"|"0"||||"0"||"1"|"COMMON"|"U"|"1957"|"3"|"0"|"Replace with conversion of building"|"1"|"COMMON"|"S"|"1990"|"10"|"0"|"Replace with conversion of building"|"1"|"COMMON"|"S"|"1957"|"22"|"0"||"0"|||||"0"|"No wood floors"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"1"|"S"|"1957"|"22"|"0"|"Repair steel angle door edges or remove with conversion of building"|"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"U"|"1957"|"3"|"0"|"Replace rusting steel panels, clean and repoint masonry, with conversion of building"|"1"|"MASONRY,METAL"|"U"|"1957"|"3"|"0"|"Reline flue or remove with conversion of building"|"0"|||||"0"||"U"|"S"|"0"|"0"|"1957"|"3"|"0"|"Provide new doors and frames with conversion of building"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1957"|"3"|"0"|"Single pane awning. Replace with conversion of building."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"minimal ponding"|"S"|"1999"|"19"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1957"|"7"|"1,000"|"Provide 1-1/2 reduced pressure zone backflow preventer"|"1"|"IRON,COPPER,PVC"|"S"|"1957"|"7"|"0"||"1"|"ELECTRIC"|"S"|"2005"|"20"|"0"||"1"|"S"|"1957"|"7"|"0"|"Replace with conversion of building"|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1957"|"3"|"150,000"|"Replace boiler and condesate pump ($120,000); remove asbestos ($30,000) or provide new system with conversion of building."|"1"|"S"|"1957"|"7"|"0"||"1"|"S"|"1987"|"3"|"150,000"|"Replace 2 rooftop units and provide new for office areas"|"1"|"S"|"1987"|"3"|"20,000"|"Replace exhaust fans"|"1"|"U"|"1957"|"3"|"50,000"|"Replace 10 unit heaters, replace condensate pump and insulate piping, or provide new heating system with conversion of building"|"1"|"S"|"1957"|"3"|"50,000"||"1"|"S"|"1957"|"3"|"75,000"|"Provide DDC controls"|"0"|"S"|"2006"|"16"|"0"||"1"|"S"|"2006"|"16"|"0"||"0"||||"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2007"|"27"|"0"||"1"|"0"|"0"|"Thresholds high at doors, toilet room inaccessible; address with remodeling"|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"1"|"0"|"FAIR"|"1"|"FAIR"|"Fresh air intake inaccessible"|"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"|"0"|"FAIR"|"Building to be converted to other district uses."|"3,800,000"|"U"|"1"|"Stieglitz Snyder Architecture"|"425 Franklin Street"|"716-828-9166"|"psnyder@stieglitzsnyder.com"|"Philip J. Snyder"|"021279"|"I ACCEPT"|12/29/2010 3:40:58 PM| 699|"Chappaqua CSD"|"66100406"|"Chappaqua Library"|"6022"|"08/24/2010"|"70 Roaring Brook Road"|"Chappaqua"|"105141710"|"ANNUAL"|"08/01/2011"|"1979"|"14800"|"1"|"0"|"1"|"DISTRICT"|"INSTRUCT"||"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"LIBBRARY"||"1"|"0"|"0"|"1"|"25000"|"E"|"2002"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1979"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1979"|"10"|"0"||"1"|"S"|"1979"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"10"|"0"|"Replacement of service should be considered during next major renovation or addition"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"1996"|"6"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1979"|"6"|"0"||"1"|"S"|"1979"|"6"|"0"||"1"|"S"|"1996"|"6"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1996"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"6"|"0"||"1"|"COMMON"|"S"|"2004"|"6"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1979"|"6"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1979"|"6"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1979"|"6"|"0"||"1"|"S"|"1979"|"6"|"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"Y"|"2003"|"6"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"3"|"0"|"Cost and comments listed for main school building 0015"|"0"|||||"0"||"1"|"COPPER"|"S"|"1979"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1979"|"10"|"0"||"1"|"NAT_GAS,OTHER"|"S"|"1996"|"10"|"0"|"Indirect units used in winter and gas fired unit in warm weather"|"1"|"S"|"1979"|"10"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"2008"|"12"|"0"||"1"|"S"|"1979"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"2004"|"6"|"0"||"1"|"S"|"2002"|"6"|"0"|"New Ric Wil underground distribution pipes done in 2002"|"1"|"S"|"2004"|"6"|"0"||"1"|"S"|"2004"|"6"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"1"|"1"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"1"||"GOOD"||"0"|"S"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/29/2010 3:41:09 PM| 700|"Cobleskill-Richmondville CSD"|"54110206"|"Cobleskill-Richmondville High School"|"0018"|"10/01/2010"|"ROUTE 7 "|"RICHMONDVILLE "|" 12149"|"ANNUAL"|"01/01/2011"|"1998"|"175700"|"2"|"5"|"1"|"DISTRICT"|"INSTRUCT"||"675"|"9,10,11,12"|"0"|"0"|"1"|"675"|"0"|"0"|||"55"|"61196"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP,OTHER"|"BOCES, Learning Resource Ctr"|"1"|"1"|"8000"|"0"|"0"|"S"|"1998"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2006"|"20"|"0"|"Converted from well to municipal 2006."|"1"|"SITESEPT"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"SURFACEH2O"||"0"|"S"|"1998"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"10"|"0"|"Asphalt sealant regualarly applied. Partial asphalt replacemetn 2009. Front road showing soem cracking, settlement."|"1"|"CONCRETE"|"S"|"2009"|"10"|"0"|"sidewalk grade near Aud. entry low, resulting in ponding water - concrete in good condition. Sidewalk cracked at Aud entry columns - may be settlement cracks, canopy does not appear to have moved - to be monitored."|"0"||||"0"||"1"|"S"|"2000"|"20"|"0"|"Y"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"20"|"0"|"minor crack in foundation south of main entry, not displaced appears same condition as 2005 BCS."|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"|"Cracking in CMU walls, second floor science wing - same condition as 2005 BCS, to be monitored."|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"15"|"0"|"rubber treads, risers"|"1"|"S"|"1998"|"20"|"0"||"1"|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"15"|"0"|"Lighting levels monitored by NYSERDA for Energy Star Program"|"1"|"1"|"S"|"1998"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1998"|"15"|"0"||"1"|"COMMON"|"S"|"1998"|"20"|"0"|"Cracks in terrazzo, not displaced, same condition as 2005 BCS"|"1"|"COMMON"|"S"|"1998"|"20"|"0"|"Gymnasium floor, stage floor"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"20"|"0"||"MASONRY,STEEL"|"0"|"1"||"1"|"0"|"1"|"0"|"0"||"S"|"1998"|"5"|"35000"|"Veertical crack in brick veneer, south of main entry. Sealant at windows poor. Deterioration at exterior column bases at exit canopies. Mildew on masonry surfaces at exit canopies, masonry deterioration."|"1"|"METAL"|"S"|"1998"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"|"Ramp added at loading dock 2009"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2009"|"20"|"0"|"2 windows replaced 2009, remainder original 1998."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"0"|"1"||"S"|"1998"|"10"|"0"|"Stained ceiling at gym lobby and leak in second floor fan room near auditorium, leak on stage. Maintenance service call required. Flashing at exhaust fan near Aud. needs sealant maintenance issue."|"1"|"PLASTIC"|"S"|"1998"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1998"|"20"|"0"||"1"|"IRON"|"S"|"1998"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2005"|"10"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"15"|"0"||"1"|"U"|"1998"|"3"|"200000"|"Replace rotary screw chiller and cooling tower."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"5"|"510000"|"Existing controls are no longer supported and spare parts are not readily available. upgrade controllers and workstations. System functions as separate sub systems, not a cohesive system."|"1"|"S"|"1998"|"15"|"0"|"No visual display devices in Auditorium, no FA system in press box in field."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"1998"|"0"|"Ansul system in kitchen hood."|"1"|"S"|"1998"|"15"|"0"||"1"|"S"|"1998"|"20"|"0"|"CAT diesel generator serves critical mechanical and emergency lighting."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"|"Lighting levels monitored by NYSERDA for Energy Star Program"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"1"|"AREAWIDE"|"0"|"0"||||"1"|"1"|"COMMSYS,HVAC,FIREALARM,FRIDGE,LIGHTING"|"FULL"||"1"||"GOOD"||"745000"|"S"|"0"|"CSArch"|"40 Beaver St Albany, NY 12207"|"518-463-8068"|"gklokiw@csarchpc.com"|"Gregory Klokiw"|"025863"|"I ACCEPT"|12/29/2010 3:45:38 PM| 701|"Three Village CSD"|"58020106"|"Nessakeag School"|"0002"|"8/8/10"|"490 Pond Path"|"Setauket"|" 11733"|"ANNUAL"|"5/1/11"|"1963"|"117,568"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"757"|"K,1,2,3,4,5,6"|"0"|"1"|"1"|"757"|"0"|"0"|||"50"|"46,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"S"|"1990"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"10"|"0"||"1"|"SITESEPT"|"E"|"2009"|"25"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2002"|"15"|"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"E"|"2010"|"20"|"11,000"|"Address ponding issues outside stage & lower level storage. Install catch basin & drywell in lawn"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2010"|"20"|"44,000"|"Replace concrete sidewalks outside Rms 41 & 42. Extend asphalt sidewalk from ext classroom door slabs to adjacent paved surfaces."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2000"|"12"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"20"|"0"|"Concrete block retaining wall outside ext loading dock showing signs of deterioration. Consider replacing the retaining walls with poured concrete walls within the next 5-6 yrs"|"1"|"S"|"1964"|"25"|"45,000"|"Several int cracks are minor & require monitoring. Several cracks are in need of attention."|"1"|"S"|"1964"|"25"|"0"||"1"|"E"|"2008"|"15"|"540,400"|"Replacement of remaining concealed spline ceilings as well as 2 x 4 ceilings in the 1963 Wing corridor"|"1"|"S"|"1963"|"10"|"0"||"1"|"S"|"S"|"2009"|"15"|"174,750"|"Long range replacement of int doors, B label doors where required, roll down door at existing kitchen tray return. Replace knobs with lever type hardware."|"1"|"S"|"1963"|"20"|"0"||"1"|"S"|"1963"|"20"|"0"||"1"|"1"|"S"|"2002"|"15"|"70,000"|"Replace trim & broken locks on panelboards, trace & provide typewritten directories, furnish & install new panelboards for spare circuits, infrared test for "hot spots", clean & tighten all connections"|"1"|"E"|"2009"|"20"|"0"||"1"|"1"|"S"|"2008"|"5"|"120,000"|"Extend devices to spaces currently not covered. Recommend replacement of 20 yr old system"|"0"||||"0"||"1"|"COMMON"|"E"|"2009"|"12"|"0"||"1"|"INSTRUCT"|"E"|"2010"|"15"|"56,000"|"We recommend replacement of remaining VAT flooring throughout the building."|"1"|"COMMON"|"S"|"1963"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1963"|"15"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"69,000"|"Repairs required to existing cupola. Also crack repairs required outside Information Center & Classroom 16"|"1"|"MASONRY"|"E"|"2009"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2002"|"20"|"48,000"|"Replace existing ext 1 pair doors & 2 pairs of existing gym ext doors & 5 pairs of corridor exit doors. Furnish & install 2nd means of egress from Room 1 (Kindergarten) to ext for easier egress for Kindergarteners"|"1"|"S"|"1963"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"10"|"47,000"|"Multiple windows require counterbalance replacement. Long range plan to replace windows should be considered"|"METONMET,WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"35"|"46,000"|"Replace gutters & leaders where needed. Cafeteria glulam beam construction gap is most likely construction tolerances. Auditorium glulam purlin beams contain horizontal cracking & recommend resin pressure injection"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"2009"|"20"|"0"||"1"|"IRON"|"S"|"2009"|"20"|"0"||"1"|"OIL"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2009"|"35"|"0"||"1"|"E"|"2009"|"35"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2008"|"2008"|"0"||"1"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"1"||"Classroom door handicapped accessibility on the room side, install automatic door actuators where required. Handicapped chairlift is required to the stage from the Auditorium."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,271,150"|"E"|"0"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/29/2010 3:49:41 PM| 704|"Williamsville CSD"|"14020306"|"South High School"|"0005"|"07/19/2010"|"5950 MAIN ST "|"WILLIAMSVILLE "|" 14221"|"ANNUAL"|"07/01/2011"|"1949"|"189767"|"2"|"10"|"5"|"DISTRICT"|"INSTRUCT"||"1011"|"9,10,11,12"|"0"|"1"|"1"|"1011"|"0"|"0"|||"53"|"33125"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1949"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1949"|"15"|"0"||"1"|"S"|"1949"|"5"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2010"|"20+"|"0"||"1"|"S"|"1949"|"10"|"0"||"0"||||"0"||"1"|"S"|"1949"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"0"||"1"|"CONCRETE"|"U"|"2004"|"2"|"130000"|"Concrete is cracking or moving and is creating a tripping hazard"|"0"||||"0"||"1"|"S"|"2010"|"10"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"|"Movement cracks visible at exterior foundation wall"|"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"2010"|"18"|"0"||"0"|"S"|"1992"|"13"|"0"||"1"|"S"|"S"|"2010"|"17"|"0"||"0"|"S"|"1949"|"20"|"0"||"1"|"S"|"1949"|"20"|"0"||"1"|"1"|"E"|"2010"|"20+"|"0"||"1"|"S"|"2009"|"5"|"0"||"1"|"1"|"S"|"2006"|"17"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"13"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1992"|"19"|"0"||"1"|"COMMON"|"S"|"1992"|"16"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"0"|"1"|"1"|"1"||"S"|"1992"|"20"|"0"||"1"|"MASONRY"|"S"|"1949"|"10"|"0"||"1"|"MASONRY"|"S"|"1992"|"20"|"0"||"S"|"S"|"1"|"1"|"1992"|"13"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"1"|"1"|"some standing water area of active leaking cracking at skylights"|"S"|"1992"|"6"|"0"||"1"|"PLASTIC"|"S"|"1992"|"6"|"0"||"1"|"COPPER"|"S"|"1950"|"5"|"0"||"1"|"IRON"|"S"|"1949"|"15"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"||"1"|"BOILERSTEA,OTHER"|"unit ventilation"|"E"|"2009"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"0"||||"0"||"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"1961"|"5"|"0"||"1"|"S"|"1961"|"5"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2003"|"20+"|"0"||"1"|"S"|"2003"|"20+"|"0"||"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1961"|"5"|"0"||"1"|"1"||"Interior portions will be upgraded in 2011 capital project"|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"INACTIVE"|"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"||"Some ceiling tiles have water stains Damage at pool area"|"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Maintenance staff noted that filters are changed approximately 3 times per year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"0"|"1"|"GOOD"||"130000"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/29/2010 4:03:50 PM| 705|"East Syracuse-Minoa CSD"|"42040106"|"Pine Grove Middle School"|"0023"|"08/31/2010"|"FREMONT RD "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/2010"|"1968"|"117,900"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"806"|"6,7,8"|"0"|"1"|"0"|"806"|"0"|"0"|||"30"|"30,800"|"ADMIN,ART,AV,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"275"|"0"|"0"|"S"|"2009"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2009"|"30"|"0"|"Site lighting upgraded w/ "Safe + Sound" project."|"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"|"Reconstructed parking lots; new access drive w/ "Safe + Sound" project."|"1"|"CONCRETE,ASPHALT"|"E"|"2006"|"20"|"0"|"Reconstructed sidewalks w/ "Safe + Sound" project."|"0"||||"0"||"1"|"S"|"1968"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"50"|"0"||"1"|"S"|"1968"|"40"|"0"|"Minor cracking at stairwells."|"1"|"S"|"1968"|"40"|"300,000"|"Recommend replacing dividing partitions between classrooms & redesign toilet rooms for ADA accessibility."|"1"|"U"|"1968"|"5"|"453,000"|"Recommend replacing all original ceilings throughout building."|"1"|"U"|"1968"|"5"|"523,000"|"Recommend replacing original lockers with larger lockers."|"1"|"U"|"U"|"1968"|"5"|"150,000"|"Replace all original doors and hardware."|"1"|"U"|"1968"|"5"|"110,000"|"Recommend replacing Terrazzo stair treads & reconfigure center stairway."|"1"|"S"|"1968"|"10"|"0"||"1"|"1"|"U"|"1968"|"5"|"140,000"|"Recommend replacing incoming 277/480V feeders and switchboard."|"1"|"E"|"2009"|"30"|"0"|"Upgraded w/ Energy Performance Contract."|"1"|"1"|"S"|"2009"|"15"|"0"|"Telephone, CCTV, access control upgraded w/ "Safe + Sound" project."|"0"||||"0"||"1"|"COMMON"|"U"|"1968"|"5"|"30,000"|"Recommend replacing original carpet at Media Center/ Administration Office."|"1"|"INSTRUCT,COMMON"|"U"|"1968"|"5"|"332,000"|"Recommend replacing flooring in classrooms and cafeteria."|"1"|"COMMON"|"S"|"1968"|"10"|"0"||"1"|"INSTRUCT"|"U"|"1968"|"5"|"17,000"|"Recommend replacing damaged wood floors at technology classrooms."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"50"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"U"|"1968"|"5"|"50,000 "|"Recommend repairing concrete facade in several locations (steel reinforcing is exposed)."|"1"|"METAL"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"S"|"U"|"0"|"1"|"2009"|"5"|"17,000"|"Several doors replaced as part of Safe & Sound Project. Recommend replacing balance of doors."|"1"|"S"|"1968"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1982"|"5"|"433,000"|"Recommend replacing curtain wall systems & windows."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"1"||"U"|"2003"|"5"|"1,018,000"|"A portion of the roof was replaced in 2003. Balance of roof beyond useful life"|"1"|"PLASTIC"|"U"|"2003"|"5"|"0"||"1"|"GALVANIZED,COPPER"|"U"|"1968"|"5"|"210,000"|"Majority of piping is galvanized steel. Recommend replacing with copper and reinsulate."|"1"|"IRON,COPPER"|"S"|"1968"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"U"|"1968"|"5"|"612,000"|"Recommend replacing remaining original fixtures"|"1"|"CV"|"1"|"BOILERWATE"||"E"|"2009"|"40"|"0"|"Replaced HW boiler plant w/ Energy Performance Contract/ 4 new boilers"|"1"|"S"|"1968"|"15"|"0"||"1"|"U"|"1968"|"5"|"148,000"|"Recommend adding A/C to serve interior zones and Administrative area."|"1"|"U"|"1968"|"5"|"4,200,000"|"Recommend replacing air handlers & constant volume air handlers - reached end of useful life"|"1"|"U"|"1968"|"5"|"87,000"|"Recommend replacing original equip @ Locker/Music rooms"|"1"|"U"|"1968"|"5"|"148,000"|"Recommend replacing original outside air dampers; clean ductwork"|"1"|"U"|"2009"|"5"|"871,000"|"Recommend replacing zone dampers/sensors"|"1"|"U"|"2000"|"5"|"210,000"|"Recommend replacing Simplex 4002 w/ point addressable system; Add classroom strobes."|"1"|"U"|"2000"|"5"|"70,000"|"Recommend replacing devices with point addressable type."|"0"||||"0"||"1"|"S"|"2009"|"10"|"0"|"Existing LED exits and battery packs in corridors."|"1"|"U"|"1969"|"5"|"175,000"|"Recommend replacing existing & add additional EM ltg., boilers, kitchen equipment etc."|"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"POOR"|"District plans to expand program space."|"10,304,000"|"U"|"1"|"King + King Architects"|"358 West Jefferson Street"|"3156826180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/29/2010 4:04:22 PM| 706|"Wyoming CSD"|"67100204"|"Main Building"|"0001"|"11/04/2010"|"State Rt 19"|"Wyoming"|" 14591"|"ANNUAL"|"10/01/2011"|"1939"|"88,872"|"3"|"1"|"0"|"DISTRICT"|"INSTRUCT"||"200"|"K,1,2,3,4,5,6,7,8"|"0"|"1"|"1"|"200"|"0"|"0"|||"21"|"15,610"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"WELL"|"S"|"1998"|"20"|"0"||"1"|"SITESEPT"|"S"|"1977"|"2"|"30,000"|"Replace septic distribution box."|"1"|"S"|"1998"|"20"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1999"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1999"|"30"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"1978"|"5"|"90,000"|"Reconstruct parking and driveways."|"1"|"CONCRETE,ASPHALT"|"S"|"1978"|"5"|"25,000"|"Reconstruct sidewalks."|"1"|"S"|"1990"|"5"|"215,000"|"Remove wood playground and install new playground."|"1"|"S"|"1978"|"5"|"125,000"|"N"|"Reconstruct baseball and soccer fields."|"RECONCRETE"|"1"|"0"|"1"|"1"|"0"|"0"|"S"|"1939"|"5"|"60,000"|"Reconstruct foundation cracks and spalling areas."|"1"|"S"|"1939"|"30"|"0"||"1"|"S"|"1939"|"30"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"30"|"0"||"1"|"S"|"S"|"1999"|"5"|"35,000"|"Replace door hardware and refinish corridor doors."|"1"|"S"|"1999"|"35"|"0"||"1"|"S"|"1999"|"30"|"0"||"1"|"1"|"S"|"1999"|"20"|"17,000"|"Replace panel boards and receptacles."|"1"|"S"|"1999"|"10"|"35,000"|"Add occupancy sensors, replace T-12 lights and exterior lighting."|"1"|"1"|"S"|"1999"|"10"|"55,000"|"Add cameras and access control."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"5"|"25,000"|"Replace flooring in classrooms."|"1"|"INSTRUCT,COMMON"|"S"|"1999"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1939"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"30"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"1"|"1"|"1"|"1"|"1"||"S"|"1999"|"30"|"150,000"|"Masonry restoration."|"1"|"MASONRY"|"S"|"1939"|"30"|"0"||"1"|"MASONRY"|"S"|"1939"|"25"|"0"||"S"|"S"|"0"|"1"|"1999"|"15"|"0"||"0"|"S"|"1999"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"20"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"10"|"50,000"|"Miscellaneous roof repairs."|"1"|"PLASTIC"|"S"|"1999"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"20"|"65,000"|"Replace galvanized piping and add controls to pressure tank."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"20"|"17,000"|"Add grease trap and replace drain lines."|"1"|"NAT_GAS"|"S"|"1999"|"10"|"20,000"|"Increase Kitchen water heater capacity."|"1"|"S"|"1999"|"5"|"48,000"|"Replace dated fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1999"|"15"|"5,000"|"Add gas detection to Boiler Room."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"30,000"|"Add A/C to Computer Room and Nurses Office."|"1"|"S"|"1999"|"20"|"345,000"|"Replace exhaust systems; install dust collection system; upgrade ventilation systems."|"1"|"S"|"1999"|"25"|"0"||"1"|"S"|"1999"|"25"|"0"||"1"|"S"|"1999"|"15"|"72,000"|"Extend DDC system and replace controls."|"1"|"S"|"1999"|"10"|"5,000"|"Expand system coverage."|"1"|"S"|"1999"|"10"|"3,000"|"Expand system coverage."|"1"|"S"|"1999"|"1999"|"0"||"1"|"S"|"1999"|"10"|"12,000"|"Add exit signs and discharge lighting."|"1"|"S"|"1999"|"20"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"1"|"1"||"GOOD"||"1,534,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/29/2010 4:09:00 PM| 708|"Kenmore-Tonawanda UFSD"|"14260103"|"Holmes Elementary"|"0030"|"11/12/2010"|"365 DUPONT AVE "|"TONAWANDA "|" 14150"|"ANNUAL"|"07/01/2011"|"1964"|"72700"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"334"|"Pre-K,K,1,2,3,4,5"|"0"|"0"|"0"|"320"|"0"|"14"|"CAFE"||"16"|"12576"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"NF"|"1964"|"1"|"136,000"|"REMOVE UNDERGROUND TANK, PIPING, ACCESSORIES, EST. 500 CU. YDS. OF CONTAMINATED SOIL AND 1000 GALLONS OF UNUSED OIL."|"1"|"MUN_UTILIT"|"S"|"1964"|"5"|"90,000"|"BACKFLOW PREVENTER AND EXTERNAL ENCLOSURE FOR DOMESTIC WATER."|"1"|"MUN_UTILIT"|"S"|"1964"|"5"|"100,000"|"REPLACE SANITARY SEWER PIPING."|"1"|"S"|"1964"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"25"|"0"||"1"|"S"|"1964"|"5"|"15,000"|"REPLACE CRACKED SECTIONS OF STORM WATER SEWER PIPING THAT FLOODS BASEMENT."|"0"||||"0"||"1"|"S"|"1964"|"5"|"25,000"|"REPLACE EXISTING CATCH BASINS IN BUS LOOP AND NORTH PARKING LOT."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"6"|"0"||"1"|"CONCRETE"|"S"|"2000"|"6"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1994"|"6"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"15"|"0"||"1"|"S"|"1964"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"5"|"40,000"|"REPLACE CEILINGS IN CORRIDORS"|"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"S"|"2004"|"2"|"75,000"|"REPLACE HARDWARE WITH LEVER LOCKSETS AND REPLACE INTERIOR DOORS."|"1"|"S"|"1964"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"0"|"S"|"2002"|"0"|"295,000"|"PROVIDE GFCI RECEPTICLES AND ADDITIONAL BRANCH CIRCUITS, REPLACE ORIGIONAL PANELS."|"1"|"S"|"2002"|"5"|"210,000"|"REPLACE THEATRICAL AND HOUSE LIGHTING IN AUDITORIUM AND VARIOUS OLDER INTERIOR AND EXTERIOR FIXTURES."|"1"|"1"|"S"|"2003"|"1"|"186,000"|"REPLACE CLOCK SYSTEM, AUDITORIUM SOUND SYSTEM AND ASSISTIVE LISTENING SYSTEM. UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT"|"S"|"1995"|"10"|"0"||"1"|"COMMON"|"S"|"1964"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1964"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"S"|"1964"|"15"|"0"||"MASONRY,OTHER"|"0"|"0"|"NONE"|"1"|"0"|"0"|"1"|"0"|"NONE"|"S"|"1964"|"2"|"600,000"|"REPLACE PRECAST PANELS WITH MASONRY WHEN REPLACING WINDOWS."|"1"|"MASONRY"|"S"|"1964"|"5"|"10,000"|"MINOR REPOINTING REQUIRED."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"5"|"100,000"|"REPLACE ALL EXTERIOR DOORS AND REPLACE SECURITY SYSTEM MOTION SENSORS."|"1"|"S"|"1995"|"15"|"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"Y"|"1964"|"2"|"800,000"|"REPLACE ALL WINDOWS ON THE ENTIRE BUILDING."|"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2004"|"20"|"0"||"1"|"PLASTIC"|"S"|"2004"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1964"|"1"|"6,000"|"INSTALL BACK FLOW PREVENTER ON BOILER MAKE-UP WATER."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2003"|"1"|"54,000"|"UPGRADE KITCHEN PLUMBING INCLUDING REPLACEMENT OF GREASE TRAPS."|"1"|"NAT_GAS"|"S"|"2003"|"5"|"87,000"|"REPLACE HOT WATER HEATERS, PIPING, STORAGE TANKS AND ACCESSORIES."|"1"|"S"|"2004"|"1"|"50,000"|"REPLACE ORIGINAL PLUMBING TRIM."|"0"||"1"|"BOILERWATE"||"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"1999"|"5"|"45,000"|"REPLACE ROOFTOP UNIT."|"1"|"S"|"1964"|"3"|"1,410,000"|"REPLACE UNIT VENTS, RELIEF HOODS AND EXHAUST"|"1"|"S"|"1964"|"3"|"225,000"|"REPLACE PUMPS, RADIANT HEAT, MISC. PIPING."|"1"|"S"|"1964"|"0"|"70,000"|"INTERNALLY CLEAN DUCTWORK."|"1"|"S"|"2002"|"5"|"190,000"|"UPDATE CONTROLS WITH NEW EQUIPMENT."|"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION DEVICES."|"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED SMOKE DETECTION."|"1"|"S"|"2002"|"2002"|"253,000"|"RECONSTRUCTION WORK AT THE STAGE, INSTALL NEW SPRINKLER SYSTEM FOR STAGE."|"1"|"S"|"2002"|"0"|"50,000"|"PROVIDE ADDITIONAL EXIT SIGNAGE, INTERIOR AND EXTERIOR EMERGENCY LIGHTING."|"1"|"NF"|"1964"|"0"|"160,000"|"REPLACE EMERGENCY GENERATOR AND DISTRIBUTION SYSTEM."|"1"|"0"|"50,000"|"PROVIDE ADA ACCESSIBILITY IN THE LOCKER ROOMS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"1"||"FAIR"||"6,300,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN STREET WILLIAMSVILLE NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/29/2010 4:24:30 PM| 710|"Plainview-Old Bethpage CSD"|"28050406"|"Plainview-Old Bethpage Middle School"|"0012"|"10/01/2010"|"121 Central Park Road"|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1959"|"209145"|"3"|"10"|"0"|"DISTRICT"|"INSTRUCT"||"800"|"5,6,7,8"|"0"|"0"|"1"|"800"|"0"|"0"|||"70"|"56,000"|"ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TECHSHOP"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1990"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"5"|"10,000"|"Provide RPZ on irrigation line."|"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"5"|"5,000"|"Replace grate over transformer."|"1"|"S"|"1960"|"10"|"0"||"0"||||"0"||"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1959"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1959"|"0"|"430,000"|"Repave south lot & overlay north lot. Reconfigure north lot for angled bus parking and add car parking to offset loss."|"1"|"CONCRETE"|"U"|"1959"|"5"|"150,000"|"Replace concrete walks at retaining wall, bus loop, locker room, main office and out to basketball courts."|"0"||||"50,000"|"Create new paved area outside locker rooms."|"1"|"U"|"1959"|"5"|"3,500,000"|"N"|"Recon 6 tennis courts, bball courts& handball crts. Reple bball backstop. New all weather track. Repl visitors bleachers (250 person capacity  no pressbox). Provide new field house w/toilets, concession, storage & B&G team locker rooms."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"15"|"85,000"|"Repair tops of courtyard retaining walls and provide elastomeric coating."|"1"|"S"|"1959"|"15"|"90,000"|"Masonry reconstruction at corridor walls, add MCJ's."|"1"|"S"|"1960"|"25"|"1,310,000"|"Renovate (3) science & (2) home ec. rooms, replace inst. storage casework, replace gym & pool bleachers, subdivide faculty lounge for SGI as well as math office."|"1"|"U"|"1959"|"5"|"108,000"|"Replace all locker room ceilings."|"0"||||"0"||"1"|"S"|"U"|"1959"|"5"|"135,000"|"Replace corridor/primary door hardware."|"1"|"S"|"1960"|"15"|"20,000"|"Add handrails at corridor ramps & replace stair wall rails."|"1"|"S"|"1960"|"5"|"0"||"1"|"1"|"S"|"1960"|"5"|"140,000"|"Provide hand dryers, additional CR & office outlets, GFI receptacle & add 6 subpanels."|"1"|"S"|"2000"|"15"|"294,000"|"Auditorium dimmer & lighting, replace pool under water lighting, provide additional auditorium house work lighting & provide additional stage work lighting & lower exist."|"1"|"1"|"S"|"1999"|"14"|"1,390,000"|"Data, IP telephony, clock, auditorium, cafeteria & gym sound systems, replace PA/intercom system."|"1"|"S"|"1960"|"5"|"205,000"|"Replace filters."|"1"|"INSTRUCT"|"S"|"1959"|"5"|"100,000"|"Replace band room carpet, auditorium, exposed concrete under banks and main office path change to VCT."|"1"|"INSTRUCT"|"S"|"1959"|"10"|"0"||"1"|"COMMON"|"U"|"1959"|"5"|"175,000"|"Repair and re-grout pool & deck, replace floor tile at locker rooms. Repair kitchen floor hump."|"1"|"COMMON"|"S"|"1959"|"10"|"30,000"|"Replace gym main backboards & shot clocks."|"SLABGRADE,OTHER"|"Concrete joist/slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1959"|"10"|"630,000"|"Complete masonry reconstruction per 2007 BBS report."|"1"|"MASONRY"|"S"|"1959"|"10"|"0"|"Included in item #61."|"0"|||||"0"||"U"|"U"|"0"|"1"|"1959"|"0"|"220,000"|"Replace all exterior doors except natatorium doors."|"1"|"S"|"1959"|"0"|"152,000"|"Repair stairs at courtyard & replace plaza areas with new pavers."|"0"|"S"|"1"|||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1959"|"0"|"3,250,000"|"Replace all windows."|"OTHER"|"SINGLEPLY,BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"S"|"2000"|"10"|"550,000"|"Recoat SPF areas & replace all skylights. (Replacement of bur areas to be done summer 2011)."|"1"|"PLASTIC"|"U"|"1959"|"5"|"0"||"1"|"COPPER"|"S"|"1960"|"5"|"20,000"|"Emegency gas shutoffs in kitchen and boiler room."|"1"|"IRON"|"S"|"1960"|"5"|"39,000"|"Duplex sump pump, roof vents/caps."|"1"|"OIL,NAT_GAS"|"S"|"2002"|"23"|"20,000"|"Provide tank type domestic water heater."|"1"|"S"|"1960"|"5"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2004"|"5"|"350,000"|"Replace 1 original boiler."|"1"|"S"|"2004"|"5"|"0"||"1"|"S"|"1990"|"5"|"700,000"|"A/C auditorium & dehumidify pool."|"1"|"S"|"1960"|"5"|"185,000"|"Copy room vent, kiln hood, refurbish gym, pool & auditorium exhaust, replace 18 exhaust fans."|"1"|"S"|"1960"|"5"|"10,000"|"Replace 2 leaking main boiler valves."|"1"|"S"|"1960"|"5"|"0"||"1"|"S"|"1990"|"5"|"340,000"|"Provide EMS, refurbish ATC system, exhaust fans to day/night system."|"1"|"S"|"1999"|"9"|"82,000"|"14 magnetic door holders & repair FA system."|"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1960"|"1960"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"NF"|"1960"|"0"|"260,000"|"Replace generator."|"1"|"0"|"870,000"|"Elevator addition at technology wing. Convert 6 toilet rooms for ADA compliance."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"1"|"1"|"0"|"FAIR"||"16,290,000"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 4:32:37 PM| 712|"Queensbury UFSD"|"63090203"|"Elementary School"|"0003"|"09/15/2010"|"431 Aviation road"|"Queensbury"|" 12804"|"ANNUAL"|"01/01/2011"|"1969"|"148036"|"1"|"9"|"1"|"DISTRICT"|"INSTRUCT"||"1017"|"K,1,2,3,OTHER"|"0"|"1"|"1"|"1017"|"0"|"0"|||"46"|"42561"|"ADMIN,ART,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,POOL,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1969"|"5"|"200000"|"Water service from High School needs to be replaced."|"1"|"SITESEPT"|"S"|"2004"|"5"|"60000"|"Odor problems, portion of septic needs to be replaced."|"1"|"S"|"2002"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2010"|"20"|"0"||"1"|"S"|"2004"|"14"|"0"||"0"||||"0"||"1"|"S"|"2004"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2004"|"14"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"80000"|"Loading dock area needs replacement"|"1"|"CONCRETE"|"S"|"2004"|"5"|"100000"|"1988 in need of replacement"|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"5"|"90000"|"N"|"Additional work to raise field elevation to control seasonal flooding and level."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"S"|"2004"|"5"|"300000"|"Replace lobby walls, casework at sinks, chalkboards"|"1"|"S"|"2004"|"20"|"300000"|"1970 Addition"|"1"|"S"|"1969"|"5"|"300000"|"Replace rusted pool lockers"|"1"|"S"|"S"|"2004"|"4"|"222000"|"Replace the few remaining original doors -222 and replace door closers -10 that no longer function."|"1"|"S"|"2004"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2010"|"5"|"150000"|"Secondary panels need replacement - 12"|"1"|"S"|"2010"|"5"|"120000"|"1969 thru 1988 fixtures need to be replaced."|"1"|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"1969"|"5"|"250000"|"Replace sand filter media - 2. Pool losing water, find leak."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"1"|"90000"|"Replace 16,143 sf"|"1"|"INSTRUCT,COMMON"|"U"|"2002"|"5"|"200000"|"Replace 32,044 sf VAT"|"1"|"COMMON"|"S"|"2004"|"20"|"0"||"1"|"COMMON"|"S"|"2004"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"Crack in SOG Lower room in pool"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"1"|"0"|"0"||"S"|"2004"|"5"|"60000"|"Clean masonry, damage to brick wall at receiving."|"1"|"MASONRY,METAL"|"S"|"2010"|"20"|"0"||"1"|"METAL"|"S"|"1969"|"20"|"0"||"S"|"S"|"1"|"1"|"2004"|"4"|"150000"|"Replace all exterior doors"|"1"|"S"|"2004"|"1"|"70000"|"Replace railing st main ramp to building, replace exterior stairs - 12."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2004"|"1"|"800000"|"Replace all single glazed windows."|"METONMET"|"SINGLEPLY,ASPHALT,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"5"|"400000"|"Hypolon 8,360 sf, MTL Mansard 1,600sf, Hypolon roof and storage roof, pool roof, transite soffits, mansard and 125,000 sf of EPDM roofing."|"1"|"PLASTIC"|"S"|"1969"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"40000"|"Replace, add 200 valves."|"1"|"IRON,PVC"|"S"|"2004"|"5"|"25000"|"1,000 sf at 25 per sf. Iron failing in basement."|"1"|"NAT_GAS"|"E"|"2010"|"20"|"0"||"1"|"S"|"2004"|"5"|"255000"|"Replace showers, water closets and EWC - 255,000"|"1"|"CV,VAV"|"1"|"BOILERWATE"||"S"|"2004"|"3"|"200000"|"Replace 1985 boilers - 3"|"1"|"E"|"2004"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2005"|"5"|"40000"|"Replace 1968 units - 2, gym roof."|"1"|"S"|"2005"|"5"|"200000"|"Replace isolation valves -100 and tie boiler plants together."|"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"2004"|"5"|"150000"|"Replace pneumatic with DDC, upgrade software to current version."|"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"2004"|"2004"|"0"|"Kitchen hood."|"1"|"S"|"2004"|"5"|"30000"|"Replace emergency lighting and exit sign battery packs."|"0"||||"0"||"1"|"1"||"Door hardware - see doors."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Source of ceiling staining not verified."|"0"|"0"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"0"||"FULL"||"0"|"0"|"GOOD"||"4882000"|"S"|"1"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"kellis@csarchpc.com"|"Kevin Patrick Ellis"|"03024456"|"I ACCEPT"|12/29/2010 4:44:34 PM| 713|"Kenmore-Tonawanda UFSD"|"14260103"|"Kenmore West Senior High School"|"0014"|"08/04/2010"|"33 HIGHLAND PKWY "|"KENMORE "|" 14223"|"ANNUAL"|"07/01/2010"|"1938"|"282,662"|"4"|"13"|"3"|"DISTRICT"|"INSTRUCT"||"1463"|"9,10,11,12"|"0"|"1"|"0"|"1463"|"0"|"0"|||"58"|"41,580"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"20,000"|"S"|"2004"|"5"|"217,000"|"Remove underground tank, piping and accessories, remove contaminated soil."|"1"|"MUN_UTILIT"|"S"|"1940"|"1"|"136,000"|"Replace water main, fire hydrant on Southeast corner of building, domestic water and athletic field backflow preventers"|"1"|"MUN_UTILIT"|"S"|"1940"|"10"|"0"||"1"|"S"|"1940"|"1"|"108,000"|"Install emergency gas shutoff system in Science and Home Economics rooms. Drop Kitchen gas shutoff below ceiling."|"1"|"UTIL"|"BELOW"|"S"|"1998"|"20"|"0"||"1"|"S"|"1996"|"15"|"0"||"0"||||"0"||"1"|"S"|"1996"|"5"|"25,000"|"Replace catch basins and replace storm piping for parking lot catch basins"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"6"|"0"||"1"|"CONCRETE"|"S"|"1996"|"6"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"S"|"1997"|"2"|"225,000"|"Replace hardware with lever locksets and closers. Replace interior doors at stairhalls."|"1"|"S"|"1940"|"10"|"0"||"1"|"S"|"1996"|"3"|"20,000"|"Upgrade existing elevator to meet A.D.A. codes."|"1"|"1"|"S"|"2002"|"0"|"217,000"|"Provide GFCI receptacles in various spaces, add emergency shutdowns, replace old wiring."|"1"|"S"|"2002"|"5"|"460,000"|"Replace Auditorium lighting/dimming systems and older lighting fixtures."|"1"|"0"|"S"|"2002"|"0"|"829,000"|"Replace public address (PA) system, clock system, Auditorium and Old Gymnasium sound systems, upgrade telephone system."|"1"|"S"|"2000"|"1"|"865,000"|"Replace entire Pool filtration system, heater and all piping."|"1"|"INSTRUCT,COMMON"|"S"|"1996"|"5"|"75,000"|"Replace carpeting in Auditorium and miscellaneous spaces."|"1"|"INSTRUCT"|"S"|"1996"|"10"|"0"||"1"|"COMMON"|"S"|"1996"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1996"|"5"|"60,000"|"Replace wood floor in old Aux. Gymnasium."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1996"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1996"|"10"|"0"||"1"|"MASONRY"|"S"|"1996"|"5"|"85,000"|"Replace cap on chimney, replace brick, new liner, repoint brick, replace reinforcing bands."|"1"|"MASONRY"|"S"|"1996"|"10"|"0"||"S"|"S"|"0"|"1"|"1999"|"5"|"23,000"|"Replace security system motion sensors."|"1"|"S"|"1999"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1996"|"10"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1999"|"5"|"75,000"|"Replace roofing system over Boiler Room."|"1"|"PLASTIC"|"S"|"1999"|"5"|"25,000"|"Replace skylights and reflash."|"1"|"GALVANIZED,COPPER"|"S"|"1995"|"1"|"6,000"|"Install backflow preventer on boiler water make-up piping."|"1"|"IRON"|"S"|"1995"|"1"|"36,500"|"Clean out and power flush basement drains and sewers, Kitchen work."|"1"|"NAT_GAS"|"S"|"1995"|"3"|"138,000"|"Replace hot water heaters, storage tanks and associated piping."|"1"|"S"|"1995"|"1"|"100,000"|"Replace Corridor drinking fountains with electric water coolers and A.D.A. electric water coolers, replace hose bibbs at gang lavatories, replace wall hydrants with non-freeze vacuum breaker type."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2003"|"5"|"460,000"|"Replace boilers and associated piping."|"1"|"S"|"2003"|"6"|"0"||"1"|"S"|"1998"|"6"|"0"||"1"|"S"|"1995"|"2"|"1,960,000"|"Replace unit ventilators, exhaust fans, relief hoods, Shop dust collection system, Gymnasium and Auditorium air handling units."|"1"|"S"|"2003"|"3"|"238,000"|"Replace boiler feed unit, traps and miscellaneous piping."|"1"|"S"|"1998"|"5"|"110,000"|"Replace Pool duct supports and provide internal duct cleaning."|"1"|"S"|"2003"|"3"|"250,000"|"Upgrade controls on air handling units and unit ventilators with new equipment."|"1"|"S"|"2002"|"0"|"125,000"|"Upgrade system. Add code required notification signals."|"1"|"S"|"2002"|"0"|"55,000"|"Provide code required smoke detection."|"1"|"S"|"2003"|"2003"|"287,000"|"Provide Stage renovations and sprinkler system for Stage."|"1"|"S"|"2002"|"0"|"150,000"|"Provide additional exit signage and miscellaneous building emergency lighting."|"1"|"U"|"1970"|"0"|"288,000"|"Replace emergency generator and distribution system."|"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"INACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"8,900,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street Williamsville NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/29/2010 4:50:39 PM| 714|"Williamsville CSD"|"14020306"|"Heim Middle School"|"0007"|"07/12/2010"|"175 HEIM ROAD "|"AMHERST "|" 14221"|"ANNUAL"|"07/01/2011"|"1964"|"122419"|"1"|"5"|"4"|"DISTRICT"|"INSTRUCT"||"644"|"5,6,7,8"|"0"|"1"|"1"|"644"|"0"|"0"|||"53"|"41340"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"5"|"0"||"1"|"S"|"1964"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"20+"|"0"||"1"|"S"|"1964"|"10"|"0"||"0"||||"0"||"1"|"S"|"1964"|"10"|"0"||"0"||||"0"||"0"|"MUNI"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"5"|"0"||"0"||||"0"||"1"|"S"|"1964"|"10"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"20"|"0"||"1"|"S"|"1964"|"20"|"0"||"1"|"S"|"1964"|"20"|"0"||"1"|"E"|"2001"|"18"|"0"||"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"S"|"1964"|"16"|"0"||"1"|"S"|"1964"|"20"|"0"|"access and egress to boiler room and mechanical space"|"0"||||"0"||"1"|"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"1"|"S"|"1964"|"5"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"17"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"11"|"0"||"1"|"COMMON"|"S"|"1964"|"19"|"0"||"1"|"COMMON"|"S"|"1964"|"18"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"2 way concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1964"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"1"|"1"|"0"||"S"|"1964"|"20"|"0"||"1"|"MASONRY"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2005"|"12"|"0"||"1"|"E"|"2005"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1985"|"20"|"0"||"OTHER"|"SINGLEPLY,BUILTUP,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"17"|"0"||"1"|"PLASTIC"|"S"|"1999"|"17"|"0"||"1"|"COPPER"|"S"|"1995"|"20"|"0"||"1"|"IRON"|"S"|"1964"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"13"|"0"||"1"|"S"|"2003"|"20"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"2004"|"20+"|"0"||"1"|"S"|"2004"|"20+"|"0"||"1"|"S"|"2009"|"18"|"0"||"1"|"S"|"2003"|"11"|"0"||"1"|"S"|"1964"|"10"|"0"||"1"|"S"|"1964"|"10"|"0"||"1"|"S"|"2002"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"1964"|"1964"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"1"||"Recent upgrades made to locker room toilets Additional toilet room upgrades recommended"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"1"|"CLASSROOMS,HALLWAYS,OTHER"|"toilet rooms"|"0"|||"1"|"1"||"Some ceiling tiles have water stains"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"|"FRIDGE"|"WARMING"||"1"||"GOOD"||"0"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/29/2010 4:55:50 PM| 715|"East Syracuse-Minoa CSD"|"42040106"|"Bus Garage"|"5005"|"08/19/2010"|"CENTRAL AVE "|"MINOA "|" 13116"|"ANNUAL"|"10/01/2010"|"1968"|"14,576"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus/Transportation Bldg."|"0"||"0"|"0"|"1"||||||"0"|"0"|"NONE,OTHER"|"Bus maintenanace"|"1"|"2"|"12,000"|"0"|"0"|"S"|"1993"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2007"|"30"|"0"|"Site lighting upgraded 2007."|"0"||||"0"||"1"|"U"|"2006"|"5"|"44,000"|"Recommend reconfiguring front swale"|"0"||||"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2006"|"5"|"88,000"|"Recommend replacing front parking asphalt."|"1"|"ASPHALT"|"S"|"2006"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"45"|"0"||"1"|"S"|"1968"|"40"|"0"||"1"|"E"|"2007"|"40"|"0"||"1"|"S"|"2007"|"25"|"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"E"|"2007"|"30"|"0"||"1"|"S"|"1968"|"45"|"0"||"1"|"S"|"1968"|"15"|"0"|"Ongoing inspection & maintenance of vehicle lifts. "|"1"|"1"|"S"|"2007"|"30"|"0"|"Upgraded power & receptacles in 2007"|"1"|"E"|"2007"|"25"|"0"||"1"|"1"|"S"|"2007"|"15"|"0"|"New phone system; intruder detection system; additional CCTV's w/ EXCEL"|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2007"|"15"|"0"||"1"|"COMMON"|"E"|"1968"|"25"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"50"|"0"||"STEEL"|"0"|"1"|"Corrosion @ columns (near entry doors)"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"5"|"2,000"|"Recommend cleaning/painting columns"|"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2007"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2007"|"30"|"0"||"OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2007"|"20"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER,PVC"|"S"|"2007"|"5"|"18,000"|"Recommend replacing PVC in wash bay; add water hammer arrestor @ bus wash system"|"1"|"IRON,COPPER"|"S"|"1968"|"5"|"26,000"|"Reconstruct cracked/broken sanitary pipe leaving building."|"1"|"ELECTRIC"|"S"|"2001"|"5"|"44,000"|"Replace electric water heater (w/ gas unit)"|"1"|"E"|"2007"|"30"|"0"||"1"|"CV"|"1"|"FURNACE"||"E"|"2007"|"25"|"0"|"Infrared radiant pipe @ garage areas"|"1"|"S"|"2007"|"25"|"0"||"1"|"E"|"2007"|"20"|"0"|"Cooling in mechanics area"|"1"|"E"|"2007"|"25"|"0"||"0"||||"0"||"1"|"E"|"2007"|"25"|"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"|"Existing Siemens FS-250 Control Panel"|"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2003"|"2003"|"0"|"Fuel island fire suppression system."|"1"|"S"|"2007"|"25"|"0"||"1"|"S"|"2005"|"30"|"0"|"Existing generator 37Kw (gas island pumps, Ansul system, lights, & main server)"|"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,FIREALARM,LIGHTING"|||"0"|"1"|"GOOD"||"222,000"|"S"|"1"|"King + King Architects"|"358 West Jefferson Street"|"3156826180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/29/2010 5:06:36 PM| 716|"Queensbury UFSD"|"63090203"|"Transportation Department"|"5020"|"08/15/2010"|"421 Aviation Road"|"Queensbury"|" 12804"|"ANNUAL"|"01/01/2011"|"1998"|"15540"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Transportation Maintenance, Driver Training and Administration"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"2"|"15400"|"0"|"0"|"S"|"1998"|"20"|"0"|"Gasoline and diesel vehicle fuel"|"1"|"MUN_UTILIT"|"S"|"1998"|"20"|"0"||"1"|"SITESEPT"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2010"|"20"|"0"||"1"|"S"|"2004"|"14"|"0"||"1"|"E"|"2010"|"5"|"100000"|"Some areas of localized flooding across road."|"1"|"S"|"2004"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2004"|"14"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"4"|"90000"|"Resurface the access road from the Intermediate School to the Bus Garage."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"5"|"20000"|"6,831 sf to replace"|"1"|"COMMON"|"S"|"2010"|"20"|"0"||"1"|"COMMON"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"5"|"6000"|"Replace dented siding"|"1"|"METAL"|"S"|"1998"|"20"|"0"|"See no. 75"|"0"|||||"0"||"S"|"S"|"1"|"1"|"2010"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2010"|"20"|"0"||"OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2010"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2010"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2010"|"15"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"CV"|"1"|"BOILERWATE,FURNACE"||"S"|"2010"|"5"|"140000"|"Replace oversized triad boilers with high efficiency condensing gas boilers including chimney and breeching."|"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2000"|"5"|"6000"|"Upgrading temperature controls to new DDC."|"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"E"|"2010"|"2010"|"0"||"1"|"S"|"2010"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"362000"|"S"|"0"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"kellis@csarchpc.com"|"Kevin Patrick Ellis"|"03024456"|"I ACCEPT"|12/29/2010 5:23:14 PM| 717|"Plainview-Old Bethpage CSD"|"28050406"|"Stratford Road Elementary School"|"0011"|"09/30/2010"|"33 Bedford Road"|"Plainview"|"11803"|"ANNUAL"|"04/01/2011"|"1960"|"141145"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"792"|"K,1,2,3,4"|"0"|"0"|"0"|"792"|"0"|"0"|||"70"|"36,800"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1995"|"35"|"1,500"|"Provide cage for overfill alarm."|"1"|"MUN_UTILIT"|"S"|"1960"|"5"|"130,000"|"Provide additional site fire hydrants."|"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"1990"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"5"|"0"||"1"|"S"|"1960"|"5"|"0"||"0"||||"0"||"1"|"S"|"1960"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1960"|"10"|"12,000"|"Add drainage N/E corner of lot to alleviate flooding."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1960"|"10"|"138,000"|"Crackfill & seal parking lots & driveways."|"1"|"CONCRETE,ASPHALT"|"S"|"1960"|"10"|"58,000"|"Replace curb & sidewalk from main entry northward, replace asphalt walk at playgrounds."|"1"|"S"|"1960"|"5"|"0"||"1"|"U"|"1960"|"5"|"1,000,000"|"N"|"Reconstruct & reorient softball field. Reconstruct tennis/basketball area from 3 tennis courts to 5, from 4 backboards to 2, replace fencing."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"10"|"90,000"|"Masonry reconstruction at corridor stack bond walls. Notably lintels and west stage door. Cut in MCJ's."|"1"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"5"|"75,000"|"Replace K-center lobby ceilings, and corridors surrounding auditorium. Repair plaster at locker soffit and 2nd floor boys room, and one skylight well. "|"1"|"S"|"1960"|"10"|"0"||"1"|"S"|"U"|"1960"|"5"|"95,000"|"Replace all corridor/primary door to locksets to levers. Replace 6 interior windows with proper rated assemblies."|"1"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"10"|"0"||"1"|"1"|"S"|"1960"|"5"|"12,000"|"Add outlets in faculty room & main office & reconnect lightning protection."|"1"|"S"|"1990"|"5"|"219,000"|"Replace dimmer board, replace auditorium lighting, repair canopy lighting, add 2 work house lights in auditorium, provide gym lighting key switch control."|"1"|"1"|"S"|"1995"|"10"|"990,000"|"Replace PA/intercom/bell, IP phones, data, auditorium sound system."|"0"||||"0"||"1"|"COMMON"|"S"|"1960"|"5"|"0"||"1"|"COMMON"|"S"|"1960"|"10"|"95,000"|"Replace auditorium carpet, expose & paint concrete beneath seating banks. (include existing seating reinstallation)."|"1"|"COMMON"|"S"|"1960"|"10"|"0"||"1"|"COMMON"|"S"|"1960"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1960"|"15"|"85,000"|"Masonry reconstruction at SW corner of W wing, repair plaster soffit in crtyd. Repair plaster soffit at entry canopy,tuckpoint upperEaudit walls&other minor masonry recon. Rbld shifted NE&NW corner of N.wing & recaulk control joints."|"1"|"MASONRY,METAL"|"S"|"1960"|"15"|"62,000"|"Remove and rebuild chimney to 12' high, removing metal extension. Add stainless steel cap."|"1"|"MASONRY"|"S"|"2000"|"15"|"0"||"S"|"S"|"0"|"1"|"1960"|"10"|"180,000"|"Replace all exterior doors & frames."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1960"|"5"|"2,700,000"|"Replace all windows."|"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"0"||"S"|"2005"|"0"|"120,000"|"Replace approx. 70 skylights. Paint roof ladders."|"1"|"PLASTIC"|"U"|"1960"|"5"|"0"||"1"|"COPPER"|"S"|"1960"|"5"|"0"||"1"|"IRON"|"S"|"1960"|"5"|"39,000"|"Provide duplex sump pump & clear & provide roof vent caps."|"1"|"NAT_GAS"|"S"|"2004"|"14"|"7,500"|"Remove 2 abandoned DHWST's."|"1"|"S"|"1960"|"5"|"0"||"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2006"|"36"|"450,000"|"Replace 1 original boiler, provide natural gas upgrade."|"1"|"S"|"2006"|"36"|"0"||"1"|"S"|"1990"|"5"|"655,000"|"Provide A/C for gym & cafeteria, provide A/C for wire closet."|"1"|"S"|"1960"|"5"|"86,000"|"Reinstall auditorium H&V belt guard & rehab unit, provide art room exhaust, repair/replace non-functioning exhaust fans, provide FAI for rooms 105A & 233. "|"1"|"S"|"1960"|"5"|"117,500"|"Refurbish steam traps, upgrade pipe to 300 wing to increase heat flow."|"1"|"S"|"1960"|"5"|"0"||"1"|"S"|"1990"|"5"|"225,000"|"Provide energy management system, refurbish ATC system, tie exhaust fans to day/night system."|"1"|"S"|"1999"|"9"|"20,000"|"Repair fire alarm system."|"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1960"|"1960"|"0"||"1"|"S"|"1990"|"5"|"5,000"|"Provide additional emergency lighting in music rooms & kindergarten gym."|"1"|"NF"|"1960"|"0"|"250,000"|"Replace non-functioning emergency generator."|"1"|"0"|"140,000"|"Convert one boys & one girls each floor gang toilet for ADA (not full reconstruction)"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"1"|"0"|"1"|"0"|"1"|"0"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"0"|"0"|"GOOD"||"8,057,500"|"U"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/29/2010 5:28:13 PM| 718|"Queensbury UFSD"|"63090203"|"High School"|"0002"|"10/15/2010"|"409 Aviation Road"|"Queensbury"|" 12804"|"ANNUAL"|"01/01/2011"|"1962"|"222630"|"1"|"12"|"0"|"DISTRICT"|"INSTRUCT"||"1193"|"9,10,11,12"|"0"|"1"|"1"|"1193"|"0"|"132"|"OTHER"|"Auditorium"|"33"|"27067"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP,OTHER"|"GED"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"SITESEPT"|"S"|"2004"|"5"|"140000"|"North west corner fields are 1978 vintage and require replacement."|"1"|"S"|"1993"|"5"|"500000"|"Propane air mixing station to provide District with dual fuel."|"1"|"UTIL"|"BELOW"|"E"|"2004"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"E"|"2010"|"14"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2010"|"5"|"50000"|"Replace dry wells in front parking lot."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"5"|"150000"|"Replace front parking lot."|"1"|"CONCRETE"|"S"|"2004"|"5"|"100000"|"Sidewalks in front of school need replacement."|"0"||||"0"||"1"|"S"|"2004"|"1"|"200000"|"N"|"Resurface, structural spray and restripe running track and also irrigate 2 fields. "|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"3"|"750000"|"Repair horizontal shear wall structural crack in wood gymnasiums. Replace metal wall system "|"1"|"S"|"2010"|"3"|"300000"|"Make larger to include classroom upgrades"|"1"|"S"|"2002"|"3"|"200000"|"Replace lockers at metal walls."|"1"|"S"|"S"|"2010"|"3"|"92000"|"Replace 1962 building doors"|"1"|"S"|"1962"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"5"|"60000"|"Approximately -6- 1962 and 1968 panels need to be replaced."|"1"|"S"|"2002"|"5"|"160000"|"Replacement needed for 50 percent of 1962 area, 100 percent of 1968 area."|"1"|"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2010"|"5"|"30000"|"Some ACM to abate."|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"2600000"|"Replace VAT"|"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"5"|"150000"|"Refinish wood gym"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2004"|"20"|"0"||"1"|"MASONRY"|"S"|"1962"|"5"|"5000"|"Clean efflorescence off of brick"|"0"|||||"0"||"S"|"S"|"1"|"1"|"2004"|"5"|"70000"|"Replace 13 doors"|"1"|"S"|"2004"|"5"|"40000"|"Replace 1969 stairs"|"0"|||||"0"||"0"|"ALUMINUM"|"U"|"Y"|"2004"|"1"|"4000000"|"Replace single glazed windows and curtain wall."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"S"|"2004"|"2"|"835000"|"Replace hypolon roofing"|"1"|"PLASTIC"|"S"|"1962"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"5"|"100000"|"Replace piping in 8 science rooms, sinks and valves"|"1"|"IRON,COPPER"|"S"|"2004"|"20"|"0"||"1"|"OTHER"|"E"|"2004"|"20"|"0"||"1"|"S"|"2004"|"5"|"200000"|"Boys shower room in 1962 building needs upgrades including 1962, 1969, 1974 gang toilet rooms."|"1"|"CV"|"1"|"BOILERWATE"||"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"2004"|"5"|"500000"|"Provide thermal storage"|"1"|"S"|"2005"|"5"|"50000"|"Replace 1962 vintage air handlers - 2- serving wood gym"|"1"|"S"|"2004"|"3"|"40000"|"Replace all chrome guard thin walled pipe south main corridor."|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2010"|"5"|"50000"|"Replace stand alon controls with DDC."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2002"|"2002"|"0"|"Kitchen hood ansul system only, annually inspected."|"1"|"S"|"2010"|"10"|"0"|"District currently replacing battery packs and exit signs."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"0"|"0"|"GOOD"||"11280000"|"U"|"1"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"kellis@csarchpc.com"|"Kevin Patrick Ellis"|"03024456"|"I ACCEPT"|12/29/2010 6:06:18 PM| 719|"Kenmore-Tonawanda UFSD"|"14260103"|"Franklin Middle School"|"0025"|"07/16/2010"|"540 PARKHURST BLVD "|"KENMORE "|" 14223"|"ANNUAL"|"07/01/2011"|"1953"|"176,085"|"3"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"517"|"6,7,8"|"0"|"0"|"1"|"517"|"0"|"0"|||"44"|"36,960"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"0"|"NF"|"1986"|"1"|"167,000"|"Remove underground tank, piping, accessories, estimated 500 cu.yds. contaminated soil and 1000 gallons of unused oil."|"1"|"MUN_UTILIT"|"S"|"1953"|"1"|"150,000"|"Relocate backflow preventer and meters to external enclosure. Add backflow preventer and enclosure for athletic fields."|"1"|"MUN_UTILIT"|"S"|"1953"|"15"|"0"||"1"|"S"|"1953"|"1"|"69,000"|"Install emergency gas shutoff system in Science rooms and Home Economics rooms."|"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"1953"|"15"|"0"||"0"||||"0"||"1"|"S"|"1983"|"5"|"20,000"|"Regrade to existing catch basins in parking lot behind building."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1983"|"5"|"210,000"|"Repave North parking lot on Middle School side."|"1"|"CONCRETE"|"S"|"1983"|"5"|"50,000"|"Replace deteriorating and broken concrete sidewalks."|"0"||||"0"||"1"|"S"|"2004"|"15"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"2004"|"5"|"305,000"|"Replace ceilings in Corridors, Classrooms and Gymnasium."|"1"|"S"|"1983"|"10"|"0"||"1"|"S"|"S"|"1983"|"3"|"75,000"|"Replace interior doors at stairhalls, Auditorium and Stage."|"1"|"S"|"1967"|"3"|"60,000"|"Install new riser covers on all stairs."|"1"|"S"|"2004"|"0"|"100,000"|"Install new elevator for A.D.A. accessibility to second floor of 1967 classroom wing."|"1"|"1"|"S"|"2002"|"0"|"271,000"|"Provide GFCI receptacles, emergency shutdowns and replace older vintage panel boards."|"1"|"S"|"2002"|"5"|"47,000"|"Replace verious older interior and exterior fixtures."|"1"|"1"|"S"|"1993"|"0"|"347,000"|"Replace public address (PA) system, clock system, and upgrade telephone system."|"1"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"2004"|"5"|"20,000"|"Replace carpet in the Auditorium."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"2004"|"3"|"60,000"|"Replace C.M.T. and quarry tile in Toilet Rooms and Kitchen areas."|"1"|"INSTRUCT,COMMON"|"S"|"1983"|"5"|"60,000"|"Replace and refinish floors in miscellaneous classrooms."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"1"|"1"|"1"|"1"|"1"|"Rusting lintels."|"S"|"1983"|"3"|"350,000"|"Masonry restoration including replacement of bricks, steel lintels with thru-wall flashing, repointing and regrouting of masonry."|"1"|"MASONRY"|"E"|"2010"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1983"|"3"|"200,000"|"Replace all exterior doors and replace security system motion detectors."|"1"|"S"|"2004"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1983"|"5"|"260,000"|"Replace remaining older single pane windows on 1967 classroom addition."|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2010"|"25"|"0"||"1"|"PLASTIC"|"S"|"1993"|"8"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1953"|"1"|"6,000"|"Install backflow preventer on boiler make-up water."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1953"|"1"|"15,000"|"Replace Kitchen grease trap and remove abandoned grease trap."|"1"|"NAT_GAS"|"S"|"2004"|"1"|"58,000"|"Replace hot water storage tank."|"1"|"S"|"2004"|"1"|"156,000"|"Renovate Locker Rooms, hose bibbs for gang lavatories, replace wall hydrant with non-freeze vacuum breaker type, replace corridor drinking fountains with A.D.A. electric water coolers."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2005"|"5"|"115,000"|"Replace Boiler Room equipment and piping."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"1990"|"12"|"0"||"1"|"S"|"2003"|"3"|"1,550,000"|"Replace unit ventilators, exhaust fans, relief hoods and miscellaneous air handling units."|"1"|"S"|"2004"|"5"|"260,000"|"Replace boiler feed unit, miscellaneous valves, traps and piping."|"1"|"S"|"2004"|"3"|"90,000"|"Internally clean miscellaneous ductwork."|"1"|"S"|"2004"|"3"|"210,000"|"Update controls on new unit ventilators and air handling units."|"1"|"S"|"2002"|"0"|"40,000"|"Provide additional code required visual signals."|"1"|"S"|"2002"|"0"|"35,000"|"Provide additional code required smoke detection."|"1"|"S"|"2002"|"2002"|"288,000"|"Stage renovations including sprinkler system for Stage."|"1"|"S"|"2002"|"0"|"150,000"|"Provide additional exit signage, interior and exterior emergency lighting."|"1"|"U"|"1983"|"0"|"178,500"|"Replace emergency generator and distribution system."|"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"|"1"|"FAIR"||"8,400,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street Williamsville NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 8:48:43 AM| 720|"Plainview-Old Bethpage CSD"|"28050406"|"John F. Kennedy High School"|"0015"|"09/27/2010"|"KENNEDY DRIVE "|"PLAINVIEW "|" 11803"|"ANNUAL"|"04/01/2011"|"1966"|"234930"|"2"|"14"|"0"|"DISTRICT"|"INSTRUCT"||"1631"|"9,10,11,12"|"0"|"1"|"1"|"1631"|"0"|"0"|||"72"|"57,600"|"ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"20,000"|"S"|"1990"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"30"|"0"||"1"|"S"|"1995"|"35"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1966"|"5"|"0"||"1"|"S"|"1966"|"10"|"0"||"0"||||"0"||"1"|"S"|"1966"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1966"|"10"|"24,000"|"Add drainage pools at athletic field to alleviate field flooding."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1966"|"5"|"470,000"|"Remove island, reconfigure and repave south lot. Install synthetic turf in courtyards to eliminate maintenance. Asphalt overlay north parking lot (not including driveway)."|"1"|"CONCRETE,ASPHALT"|"S"|"1966"|"5"|"45,000"|"Replace sidewalks and curbs east side of building. Replace asphalt walk around west side of building"|"0"||||"0"||"1"|"S"|"1966"|"10"|"3,600,000"|"N"|"Repl visitors bleachers (250 capacity w/press plat).Inst syn turf,sports ltg.&add 2 new tennis crts. Rpr h-ball courts&repl fencing at handball&tennis.Repl bball backstop.Prov new field house w/toilets, concession, storage&B&Gteam LR."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1966"|"25"|"1,500"|"Patch at pipe in boiler room."|"1"|"S"|"1966"|"15"|"50,000"|"Minor interior masonry reconstruction, add control joints, recaulk existing joints."|"1"|"S"|"1966"|"25"|"1,165,000"|"Recon top of walls at TV studio, recon LR, create sound/projection platform within LGI. Recontoilet rms across from cafet, annexing faculty toilets. Paint LGI clg. Reset course of black beneath gym mezzanines. Repl gym operable partitions."|"1"|"S"|"2000"|"10"|"458,000"|"Replace all corridor ceilings & lighting."|"1"|"S"|"1966"|"10"|"250,000"|"Replace locker room lockers in conjunction with item #46."|"1"|"U"|"U"|"1966"|"5"|"384,000"|"Replace all corridor/primary doors."|"1"|"S"|"1966"|"15"|"0"||"1"|"S"|"1966"|"15"|"0"||"1"|"1"|"S"|"1966"|"5"|"215,000"|"Additional circuits to CRs, lightning protection, 12 hand dryers, add 4 new subpanels, reconnect HW pump VSDs & power for batting cages."|"1"|"S"|"1990"|"5"|"725,000"|"Fluorescent stage ltg, repl LGI ltgs, add'l security lighting, hallway lighting, theatrical lighting, football field lighting, tennis court lighting, auditorium lighting & fan room lighting."|"1"|"1"|"S"|"1996"|"5"|"1,487,500"|"Repl secsys,clocks,gymPA,IP teleph,data upgrades(25 switches)&WAPs,add 40 add'lCCTVcam,replPA/int sys,audit sound sys,add mtn detec 1st flr new add, provide data, elec ckts for new 1st flr comp rm by lib&add16SmartBoards."|"1"|"S"|"2000"|"10"|"420,000"|"Replace main drain lines, replace & reconfigure filter room, provide isolation valve & replace heater."|"1"|"COMMON"|"S"|"1966"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"1966"|"5"|"356,000"|"Replace all corridor VAT flooring with new VCT."|"1"|"COMMON"|"S"|"1966"|"10"|"78,000"|"Replace pool deck tile."|"1"|"COMMON"|"S"|"1966"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1966"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1966"|"25"|"50,000"|"Minor masonry reconstruction & recaulk certain control joints."|"1"|"MASONRY"|"S"|"1966"|"10"|"38,000"|"Remove & replace concrete chimney cap and upper 3 courses of brick. Add S/S cap."|"0"|||||"0"||"U"|"S"|"0"|"1"|"1966"|"10"|"120,000"|"Replace all exterior doors & frames, except one set at pool, and 2001 building additions."|"1"|"S"|"2005"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1966"|"5"|"1,500,000"|"Replace all windows and paint lintels (except 2001 additions). Remove gravel stop at curtain walls and caulk open head-joint."|"OTHER"|"BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"S"|"2000"|"5"|"1,275,000"|"Repl all skylights. Lower six roof drains & repitch SPF roofing, scarify & repitch lower roof area south of pool, repair roof leaks & recoat entire roof for consistent warranty. $150,000 allowance to redesign main entry."|"1"|"PLASTIC"|"S"|"1966"|"5"|"0"||"1"|"COPPER"|"S"|"1966"|"5"|"119,000"|"Replace mising valve in BR, replace (6) hose faucets & emergency gas shutoff in kitchen & replace isolation valves."|"1"|"IRON"|"S"|"1966"|"5"|"66,000"|"Provide roof vent caps & clear vents, add floor drains to LR's."|"1"|"OIL,NAT_GAS"|"S"|"2004"|"14"|"9,500"|"Repair leaking DHWH pump, remove DHWST."|"1"|"S"|"1966"|"5"|"31,000"|"Replace Bradley sinks & add urinals to boys locker room."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2005"|"35"|"42,000"|"Add emergency gas shutoff in BR, replace Iron Fireman burner."|"1"|"S"|"2005"|"35"|"21,000"|"Remove old #6 oil heaters & connect pony boiler to gas."|"1"|"S"|"1990"|"10"|"215,000"|"Replace 9 window A/Cs, A/C room 150, A/C cafeteria."|"1"|"S"|"1966"|"10"|"826,000"|"Additional heat in art gallery, FAI for computer room, , vent for filter room, replace (4) UVs, replace exhaust fans (40), replace pool fan room exhaust fan, refurbish pool AHUs & provide dehumidify for pool, replace kitchen hood exhaust fan."|"1"|"S"|"1966"|"5"|"0"||"1"|"S"|"1966"|"5"|"0"||"1"|"S"|"1990"|"5"|"354,000"|"New EMS, refurbish ATC system."|"1"|"S"|"1999"|"9"|"45,000"|"Repair fire alarm system."|"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1966"|"1966"|"0"||"1"|"S"|"1990"|"5"|"0"||"1"|"S"|"1985"|"25"|"39,000"|"Add 2nd pump, add 2 additional boilers."|"1"|"0"|"75,000"|"Add chairlift to basement."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Common Areas"|"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"1"|"0"|"0"|"FAIR"|"Requested orchestra room addition ($750,000)"|"15,284,500"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/30/2010 8:53:43 AM| 722|"Oneida City SD"|"25140001"|"Otto Shortell Middle School"|"0010"|"08/27/2010"|"MARKELL DRIVE "|"WAMPSVILLE "|" 13163"|"ANNUAL"|"11/01/2010"|"1967"|"84965"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"372"|"7,8"|"0"|"0"|"1"|"372"|"0"|"0"|||"39"|"30000"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,TEACHRSRC,TECHSHOP"||"1"|"1"|"500"|"0"|"0"|"S"|"1985"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1967"|"15"|"0"||"1"|"SITESEPT"|"U"|"1967"|"5"|"700000"|"Recommend replacing (2) septic fields (age/code issues)"|"1"|"S"|"1967"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"|"Storm inlets & drywells utilized"|"1"|"S"|"1967"|"10"|"0"|"30" culvert runs under the tennis courts"|"1"|"SURFACEH2O,ONSITE,OTHER"|"Stream"|"1"|"S"|"1967"|"5"|"7000"|"Discharge to adjacent property (minor erosion) - recommend rip-rap stone"|"1"|"S"|"1996"|"20"|"0"|"Drywell structure used in stormwater collection system"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1996"|"5"|"438000"|"Recommend replacing bus loop/service area asphalt"|"1"|"CONCRETE,ASPHALT"|"U"|"1996"|"5"|"70000"|"Recommend replacing curbs/sidewalks @ bus loop"|"1"|"U"|"1996"|"5"|"4000"|"Swing requires additional play mulch"|"1"|"U"|"2009"|"5"|"262000"|"N"|"B'Ball court requires re-sealing; softball fields require clay skinned; recondition turf & improve drainage"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"25"|"0"||"1"|"S"|"1997"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"|"Refinished corridor walls (paint & tile wainscot) w/ EXCEL funds."|"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"New district-wide VOIP telephone system "|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"25"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"25"|"0"|"VAT abated @ Band Rm w/ EXCEL funds."|"1"|"COMMON"|"S"|"1967"|"25"|"0"||"1"|"INSTRUCT"|"S"|"1967"|"20"|"0"|"ongoing maintenance (sealing)"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"25"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"25"|"0"||"1"|"MASONRY,CONCRETE"|"S"|"1997"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"25"|"0"|"New security system w/ EXCEL funds."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1997"|"5"|"140000"|"Storefront panels corroded. Recommend replacing."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"U"|"2009"|"5"|"1400000"|"Recommend replacing '67/'97 roofs (beyond useful life)"|"1"|"PLASTIC"|"S"|"2009"|"10"|"0"||"1"|"COPPER"|"S"|"1984"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1984"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"20"|"0"||"1"|"S"|"1984"|"15"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2002"|"15"|"0"|"Cast Iron sectional; firing gas/making hot water; 1 new-EPC, 1 older"|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"U"|"1996"|"5"|"175000"|"Recommend replacing"|"1"|"U"|"1996"|"5"|"175000"|"Recommend replacing"|"1"|"S"|"1984"|"1984"|"0"||"1"|"U"|"1996"|"5"|"21000"|"Recommend replacing"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"|"District is considering building consolidation, which may affect the MS."|"3392000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 9:03:37 AM| 725|"Kenmore-Tonawanda UFSD"|"14260103"|"Franklin Elementary"|"0026"|"07/21/2010"|"500 PARKHURST BLVD "|"KENMORE "|" 14223"|"ANNUAL"|"07/01/2011"|"1950"|"119,775"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"520"|"Pre-K,K,1,2,3,4,5"|"0"|"0"|"1"|"520"|"0"|"0"|||"18"|"16,050"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"NF"|"1986"|"1"|"167,000"|"Remove underground tank, piping, accessories, estimated 500 cu.yds. of contaminated soil and 1,000 gallons of unused oil."|"1"|"MUN_UTILIT"|"S"|"1950"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"12"|"0"||"1"|"S"|"1950"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"1950"|"5"|"75,000"|"Replace section of deteriorated storm piping."|"0"||||"0"||"1"|"S"|"1950"|"2"|"20,000"|"Regrade to existing catch basins."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1991"|"7"|"0"||"1"|"CONCRETE"|"S"|"1990"|"4"|"50,000"|"Replace deteriorating and broken concrete sidewalks and curbs."|"1"|"S"|"1997"|"15"|"0"||"1"|"S"|"1997"|"12"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"10"|"0"||"1"|"S"|"1950"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"5"|"125,000"|"Replace ceilings in Corridors, Locker Rooms, miscellaneous Classrooms and Kitchen area."|"1"|"S"|"1950"|"5"|"275,000"|"Replace all Corridor and Locker Room lockers."|"1"|"S"|"S"|"2004"|"2"|"110,000"|"Replace hardware with lever locksets and replace interior doors at stairhalls, Gymnasium and Auditorium."|"1"|"S"|"1950"|"3"|"70,000"|"Install riser/tread covers on all stairs."|"1"|"E"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"1"|"220,000"|"Replace older vintage electrical panels and wiring."|"1"|"S"|"2002"|"5"|"289,000"|"Replace Auditorium theatrical and house lighting and miscellaneous exterior lighting."|"1"|"1"|"S"|"1998"|"0"|"288,000"|"Replace clock system, upgrade telephone system and Auditorium sound system."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"3"|"35,000"|"Replace carpet in Auditorium and Library."|"1"|"INSTRUCT,COMMON"|"S"|"1997"|"7"|"0"||"1"|"COMMON"|"S"|"1997"|"7"|"0"||"1"|"INSTRUCT"|"S"|"1950"|"5"|"100,000"|"Replace wood floors in various Classrooms."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1950"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"1"|"1"|"0"|"1"|"1"|"None"|"S"|"2008"|"2"|"165,000"|"Masonry restoration required. Replace steel lintels, repoint and regrout masonry, install new flashing."|"1"|"MASONRY"|"S"|"2010"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2004"|"2"|"120,000"|"Replace all exterior doors and replace security system motion sensors."|"1"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1987"|"12"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2010"|"25"|"0"||"1"|"PLASTIC"|"S"|"2010"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1950"|"6"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1950"|"1"|"60,000"|"Kitchen upgrades."|"1"|"NAT_GAS"|"S"|"2003"|"15"|"0"||"1"|"S"|"2005"|"5"|"400,000"|"Renovate Locker Rooms, replace drinking fountains with A.D.A. electric water coolers, replace Classroom sinks and lavatories, replace hose bibbs in gang lavatories, replace wall hydrants with non-freeze vacuum breaker type."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2005"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"1990"|"7"|"0"||"1"|"S"|"2003"|"3"|"1,170,000"|"Replace unit ventilators, exhaust fans, relief hoods and miscellaneous ventilation systems."|"1"|"S"|"2003"|"3"|"95,000"|"Replace traps, valves and miscellaneous piping."|"1"|"S"|"2003"|"3"|"70,000"|"Internally clean miscellaneous ductwork."|"1"|"S"|"2003"|"5"|"230,000"|"Update controls on new unit ventilators and air handling units."|"1"|"S"|"2002"|"0"|"25,000"|"Provide additional code required notification signals."|"1"|"S"|"2002"|"0"|"20,000"|"Provide additional code required smoke detection."|"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2002"|"0"|"95,000"|"Provide interior and exterior emergency lighting."|"1"|"U"|"1996"|"0"|"178,000"|"Replace emergency generator and distribution system."|"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"5,600,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street Williamsville NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 9:35:48 AM| 726|"Queensbury UFSD"|"63090203"|"Middle School"|"0001"|"11/15/2010"|"455 Aviation Road"|"Queensbury"|" 12804"|"ANNUAL"|"01/01/2011"|"1950"|"148205"|"2"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"886"|"6,7,8"|"0"|"1"|"1"|"886"|"0"|"0"|||"33"|"33167"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"20"|"0"||"1"|"SITESEPT"|"S"|"2004"|"5"|"100000"|"Replace remaining original sanitary piping."|"1"|"S"|"2004"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2010"|"20"|"0"||"0"||||"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"10"|"0"||"1"|"CONCRETE"|"E"|"2010"|"10"|"0"||"0"||||"0"||"1"|"S"|"1989"|"5"|"600000"|"N"|"Resurface and restripe basketball court, baseball field and other miscellaneous fields striped as needed. Overused play field need to be revitalized, reconstructed."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"5"|"200000"|"Toilet room upgrades to support plumbing improvements."|"1"|"S"|"2010"|"1"|"316000"|"Tile and grid for lighting."|"1"|"S"|"2002"|"5"|"300000"|"Replace locker room lockers. Small locker need to be made larger and inadequate locker space."|"1"|"S"|"S"|"2010"|"5"|"150000"|"Replace original 1950s building doors."|"1"|"S"|"1952"|"20"|"0"||"1"|"S"|"1989"|"20"|"0"||"1"|"1"|"S"|"2010"|"5"|"200000"|"Replace secondary panels."|"1"|"S"|"2010"|"5"|"180000"|"1950-1981 fixtures need replacement, approximately 80 percent of building."|"1"|"1"|"S"|"2004"|"5"|"25000"|"Replace sound system."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"5"|"94000"|"Replace 1950 - 1998 carpet."|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"5"|"120000"|"Replace VAT."|"1"|"COMMON"|"S"|"2010"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"1"|"MASONRY"|"S"|"2004"|"5"|"100000"|"Line chimney with stainless steel, replace breeching, chimney."|"1"|"MASONRY"|"S"|"2004"|"20"|"0"||"S"|"S"|"1"|"1"|"2010"|"5"|"90000"|"Replace exterior doors."|"1"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2010"|"1"|"1000000"|"Replace single glazed windows."|"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"5"|"800000"|"Replace hypolon roofing."|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"2010"|"5"|"180000"|"Replace piping in 1950s and 1960s buildings."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2010"|"5"|"90000"|"For original toilet rooms in 1950s and 1960s vintage areas."|"1"|"NA"|"S"|"2005"|"10"|"0"||"1"|"S"|"2010"|"5"|"90000"|"For original toilet rooms in 1950s and 1960s vintage areas."|"1"|"CV,VAV"|"1"|"BOILERWATE,BOILERSTEA"||"S"|"2010"|"5"|"50000"|"Convert steam system to hot water."|"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"15"|"0"||"1"|"S"|"2010"|"20"|"200000"|"Replace steam UVs to hot water."|"1"|"S"|"2010"|"5"|"300000"|"Cost to replace remaining steam piping with hot water."|"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"5"|"100000"|"DDC with UV replacements"|"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"E"|"2010"|"2010"|"0"|"Kitchen hood, ansul, annual maintenance required."|"1"|"S"|"2010"|"5"|"30000"|"Emegency lighting and exit signs need to have their battery packs replaced."|"1"|"S"|"1981"|"1"|"100000"|"50kW natural gas generac needs overhaul or replacement, serves standby loads i.e. minimal building heat."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"1"|"HVAC"|"FULL"||"1"||"GOOD"||"5415000"|"S"|"1"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"kellis@csarchpc.com"|"Kevin Patrick Ellis"|"03024456"|"I ACCEPT"|12/30/2010 9:36:14 AM| 727|"Pavilion CSD"|"18120104"|"Jr Sr High School"|"0001"|"11/02/2010"|"7014 BIG TREE RD "|"PAVILION "|" 14525"|"ANNUAL"|"08/01/2011"|"1935"|"146,469"|"3"|"8"|"0"|"DISTRICT"|"INSTRUCT"||"475"|"6,7,8,9,10,11,12"|"0"|"0"|"0"|"475"|"0"|"0"|||"25"|"20,500"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"1"|"500"|"0"|"0"|"S"|"2000"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"40"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"40"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"0"||||"0"||"1"|"S"|"2000"|"25"|"0"||"1"|"S"|"2000"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2000"|"10"|"300,000"|"Construct new parking and reconstruct existing driveway."|"1"|"CONCRETE"|"S"|"2000"|"5"|"3,000"|"Rconstruct sidewalks."|"0"||||"0"||"1"|"S"|"2000"|"10"|"100,000"|"N"|"Re-line track; renovate softball field; reconstruct tennis courts."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"50"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"20"|"70,000"|"Replace ceilings in classrooms."|"1"|"S"|"2000"|"30"|"0"||"1"|"S"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"50"|"0"||"1"|"1"|"S"|"2000"|"20"|"53,000"|"Replace panel boards; add receptacles; replace motor starters."|"1"|"S"|"2000"|"10"|"89,000"|"Replace gym lights; add occupancy sensors; replace T-12 fixtures."|"1"|"1"|"S"|"2010"|"10"|"98,000"|"Add cameras and access controls."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"100,000"|"Abate VAT and install VQT."|"1"|"COMMON"|"S"|"2000"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"30"|"112,000"|"Masonry restoration."|"1"|"MASONRY"|"S"|"1936"|"10"|"0"||"1"|"MASONRY"|"S"|"1936"|"15"|"0"||"S"|"S"|"0"|"1"|"2000"|"25"|"0"||"1"|"S"|"2000"|"5"|"30,000"|"Replace exit stairs outside of Boiler Room and Home Economics."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"25"|"275,000"|"Ninety windows have condensation or damaged glazing; replace windows at 1930 and 1950 wings."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"5"|"900,000"|"Replace roof at "C" and "D" wings of school."|"1"|"PLASTIC"|"S"|"2000"|"5"|"0"|"Included in Number 68U."|"1"|"COPPER"|"S"|"2002"|"20"|"20,000"|"Add RPZ to boiler piping."|"1"|"IRON,COPPER"|"S"|"2002"|"15"|"10,000"|"Replace sump pump."|"1"|"NAT_GAS"|"S"|"1996"|"6"|"0"||"1"|"S"|"2002"|"15"|"62,000"|"Replace dated fixtures and faucets."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1995"|"20"|"12,000"|"Add gas detection to Boiler Room; add water softener to boiler fill piping."|"1"|"S"|"1995"|"25"|"0"||"1"|"S"|"2000"|"15"|"15,000"|"Add A/C to Room 215."|"1"|"S"|"2000"|"20"|"280,000"|"Upgrade exhaust, relief and ventilation systems."|"1"|"S"|"2000"|"20"|"164,000"|"Replace convectors and radiation heaters; replace condensate pumps."|"1"|"S"|"2000"|"25"|"32,000"|"Clean duct systems; install new ductwork at small Gymnasium."|"1"|"S"|"2000"|"15"|"100,000"|"Extend DDC system."|"1"|"S"|"2000"|"10"|"6,000"|"Add pull stations and expand coverage."|"1"|"S"|"2000"|"10"|"16,000"|"Expand coverage of system."|"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2000"|"10"|"20,000"|"Add discharge lighting; upgrade exit signs."|"1"|"S"|"2000"|"20"|"72,000"|"Provide two-hour rated construction at Generator Room and segregate life safety loads."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"||"2,939,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/30/2010 9:41:32 AM| 728|"Chittenango CSD"|"25160106"|"Middle School"|"0005"|"06/29/2010"|"1732 Fyler Road"|"Chittenango"|" 13037"|"ANNUAL"|"09/01/2011"|"1951"|"130,285"|"2"|"6"|"1"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"535"|"6,7,8"|"0"|"1"|"1"|"535"|"0"|"0"|||"38"|"34,200"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1990"|"40"|"0"||"1"|"SITESEPT"|"S"|"1991"|"41"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"30"|"0"||"0"||||"0"||"1"|"S"|"1991"|"15"|"3,000"|"Clean debris and redefine drainage swale located south of school (approximately 400 LF)."|"1"|"S"|"2005"|"15"|"1,500"|"Clean debris from inlets and pipes, throughout site."|"1"|"U"|"1991"|"10"|"1,000"|"Clean debris from end section to allow storm water drainage."|"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"10"|"72,625"|"Repair cracks, patch, seal and restripe bus loop and east parking area and southern parking area adjacent to bus loop. Remove and replace heavy duty asphalt south end of bus loop to correct drainage."|"1"|"CONCRETE,ASPHALT,OTHER"|"U"|"2000"|"15"|"128,750"|"Remove, replace and reset pavers to repair tripping hazards. Remove and replace asphalt and reset pavers at the bus loop entry."|"1"|"U"|"1995"|"0"|"7,000"|"Repair cracks, patch, seal, color coat and stripe baskeball court area."|"1"|"U"|"1991"|"3"|"55,000"|"N"|"Renovate infield and provide underdrainage. Baseball and softball dugouts."|"RECONCRETE"|"0"|"0"|"1"|"1"|"0"|"0"|"S"|"2000"|"70"|"13,000"|"Clean and patch angle and front face at loading dock. Clean and patch/seal cracks and spalling in crawlspace."|"1"|"S"|"2000"|"50"|"0"||"1"|"S"|"1989"|"50"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"S"|"2000"|"15"|"32,000"|"Some doors that open to corridors need closers approx. 20. Knob hardware to be replace with lever approx. 50."|"1"|"S"|"1991"|"25"|"0"||"1"|"S"|"1991"|"45"|"0"||"1"|"1"|"S"|"2000"|"20"|"80,000"|"Replace 1951 and 1961 basement vintage distribution equipment. Add receptacles."|"1"|"S"|"2000"|"10"|"126,000"|"Replace gymnasium HID fixtures. Replace T12 fixtures at Technology Suite. Add occupancy sensors. Add exterior lighting controls."|"1"|"1"|"S"|"1996"|"0"|"140,500"|"Replace public address/intercom system. Add ADA hearing assistance at gymnasium and cafeteria/auditorium."|"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"10"|"24,000"|"Replace VCT in cafeteria in the next 5 years."|"1"|"COMMON"|"S"|"2000"|"15"|"0"||"1"|"COMMON"|"S"|"2005"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"55"|"0"||"CONCRETE,MASONRY"|"0"|"1"||"1"|"0"|"0"|"0"|"0"||"S"|"2000"|"45"|"21,000"|"Clean and reinforce bottom columns in crawlspace. Recaulk EJ and CJ around building. Clean, patch and parge exterior of concrete columns in cafeteria/auditorium. Clean and repaint various lintels to remove rust."|"1"|"MASONRY"|"S"|"1951"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"20"|"24,000"|"Replace (6) sets of doors around gymnasium area."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"10"|"180,000"|"Replace old single glazed windows in the 1951 classroom addition."|"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"S"|"2000"|"5"|"1,200,000"|"Provide additional roof drains on roof over AV storage. Repair ladder to roof over AV storage. Replace roofing on approximately 1/2 of the building."|"1"|"PLASTIC"|"S"|"2000"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1990"|"15"|"14,500"|"Add/replace isolation valves. Test backflow preventers."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1990"|"15"|"62,500"|"Add plaster traps. Correct shower drainage. Replace sump pumps."|"1"|"NAT_GAS"|"S"|"1990"|"5"|"38,000"|"Increase hot water storage temperature. Add a thermostatic mixing valve and run a separate 140 deg hot water loop to kitchen. Inspect hot water tank internals. Replace thermometers."|"1"|"S"|"1990"|"10"|"31,000"|"Replace outdated fixtures."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"1991"|"5"|"0"||"1"|"S"|"2005"|"15"|"61,500"|"Add visual notification appliances. Add (3) pull stations at locations identified."|"1"|"S"|"2005"|"15"|"1,500"|"Add detection at (4) locations identified."|"1"|"S"|"1990"|"1990"|"3,000"|"Add fire extinguishers and cabinets."|"1"|"S"|"1996"|"1"|"45,000"|"Replace exit fixtures and wiring."|"1"|"S"|"2005"|"25"|"250,000"|"Provide NFPA Level 1 generator."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"1"|"0"||||"0"|"0"||||"1"||"GOOD"||"3,401,288"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/30/2010 9:42:05 AM| 729|"Fairport CSD"|"26130106"|"Minerva DeLand High School"|"0002"|"08/19/2010"|"140 HURLBURT ROAD "|"FAIRPORT "|" 14450-2458"|"ANNUAL"|"08/01/2011"|"1957"|"120827"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"602"|"9"|"0"|"0"|"1"|"602"|"0"|"0"|||"23"|"19232"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"MUN_UTILIT"|"E"|"2010"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1957"|"25"|"0"||"1"|"S"|"2010"|"10"|"0"||"0"||||"0"||"1"|"S"|"1957"|"10"|"0"||"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1957"|"5"|"602380"|"Main parking lot is failing."|"1"|"CONCRETE,ASPHALT"|"S"|"2010"|"10"|"0"||"0"||||"0"||"1"|"S"|"1957"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"U"|"2010"|"5"|"189211"|"Replace corridor lockers"|"1"|"S"|"S"|"2010"|"20"|"0"||"1"|"U"|"1957"|"5"|"40050"|"Terrazzo treads need to be patched and or replaced"|"1"|"U"|"1957"|"1"|"45825"|"Replace hydraulic jack"|"1"|"1"|"E"|"2010"|"30"|"0"|"1 Replace original panels 2 Add emergency stop for kitchen"|"1"|"S"|"2010"|"20"|"0"|"1 Replace occupancy sensors 2 Replace incandescent lights"|"1"|"1"|"E"|"2010"|"10"|"0"|"1 Replace PA system 2 Add access contol 3 Add cameras"|"1"|"S"|"2005"|"15"|"0"|"Add a gas fired pool water heater"|"1"|"COMMON"|"S"|"2010"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"2010"|"5"|"195367"|"Abate 300 wing classroom VAT"|"1"|"COMMON"|"S"|"2010"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1976"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"20"|"0"||"MASONRY,STEEL,OTHER"|"1"|"0"||"1"|"0"|"0"|"0"|"0"|"Curtain wall panels ending useful life"|"U"|"2010"|"5"|"1987162"|"1 Repoint brick veneer 2 Add expansion joints 3 Replace curtain wall panels"|"1"|"MASONRY"|"U"|"1957"|"5"|"20025"|"Repoint repair chimney"|"0"|||||"0"||"U"|"U"|"0"|"1"|"2010"|"5"|"12015"|"Replace cafeteria doors"|"1"|"U"|"1957"|"1"|"25639"|"Replace north stairs and railings"|"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1957"|"5"|"1529497"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2010"|"15"|"0"|"Replace shut off valves"|"1"|"IRON,COPPER"|"S"|"2010"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1999"|"5"|"0"|"Replace heaters tanks heat exchanger and pumps."|"1"|"S"|"2010"|"10"|"0"|"Update boys hsoers and replace dated faucets sinks and lavs"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1957"|"2"|"0"|"Replace boiler plant"|"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"2010"|"20"|"0"|"1 Add AC to data closets 2 Replace window AC with split systems"|"1"|"S"|"2010"|"15"|"0"|"1 Replace pool dehumidification system 2 Replace kitchen air handling system 3 Replace dust collection system 4 Replace orginal exhaust relief fans 5 Refurbish orginal AHU's 6 Add exhaust ventilation systems 7 Replace air handling systems"|"1"|"S"|"2010"|"15"|"0"|"1 Replace bulding isolation valves 2 Replace building pumps"|"1"|"S"|"2010"|"20"|"0"|"1 Clean auditorium and cafe ductwork systems 2 Clean exhaust systems 3 Replace supply registers and return grilles"|"1"|"S"|"2010"|"10"|"0"|"Remove pneumatic control system and convert to electronic"|"1"|"S"|"2010"|"10"|"0"|"Expand horn and strobe coverage"|"1"|"S"|"2010"|"10"|"0"|"Expand smoke and heat coverage"|"1"|"S"|"1980"|"1980"|"0"|"Add fire suppression sytem to kitchen hood"|"0"|"S"|"2010"|"10"|"0"|"1 Add emergency lighting 2 Add discharge lighting "|"1"|"E"|"2010"|"30"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"1"|"0"||"FULL"|"0"|"0"|"0"|"GOOD"||"7461870"|"U"|"1"|"Clark Patterson Lee"|"205 St. Paul Suite 500 Rochester NY 14604"|"585-454-4570"|"tliebert@clarkpatterson.com"|"Todd M Liebert"|"021538"|"I ACCEPT"|12/30/2010 9:44:14 AM| 730|"Kenmore-Tonawanda UFSD"|"14260103"|"JEFFERSON ELEMENTARY SCHOOL"|"0013"|"09/15/2010"|"250 ATHENS BLVD "|"KENMORE "|" 14223"|"ANNUAL"|"04/07/2011"|"1956"|"66198"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"303"|"K,1,2,3,4,5"|"0"|"1"|"1"|"303"|"0"|"0"|||"17"|"18140"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"15,000"|"NF"|"2000"|"1"|"195,000"|"REMOVE UNDERGROUND TANK, PIPING, ACCESSORIES, EST. 675 CU. YDS. OF CONTAMINATED SOIL AND 1000 GALLONS OF UNUSED OIL. "|"1"|"MUN_UTILIT"|"S"|"1956"|"1"|"69,000"|"BACKFLOW PREVENTER AND EXTERNAL ENCLOSURE FOR DOMESTIC WATER."|"1"|"MUN_UTILIT"|"S"|"1956"|"15"|"0"||"1"|"S"|"1956"|"1"|"6,000"|"INSTALL FENCE AROUND METER SETTING, 2" GAS SERVES DOMESTIC HOT WATER AND IGNITION OF BOILER PLANT."|"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"1956"|"5"|"50,000"|"REPLACE SECTION OF DETERIORATED STORM PIPING."|"0"||||"0"||"1"|"S"|"1985"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"7"|"0"||"1"|"CONCRETE"|"S"|"1985"|"5"|"25,000"|"REPLACE DETERIORATING AND BROKEN CONCRETE SIDEWALKS AND CURBS."|"1"|"S"|"2002"|"17"|"0"||"1"|"S"|"1985"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2004"|"20"|"0"||"1"|"S"|"1956"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"5"|"100,000"|"REPLACE CEILINGS IN THE CORRIDORS AND GYMNASIUM."|"1"|"S"|"1985"|"5"|"80,000"|"REPLACE LOCKERS IN THE BOYS AND GIRLS LOCKER ROOMS."|"1"|"S"|"S"|"2004"|"2"|"25,000"|"REPLACE HARDWARE WITH LEVER LOCKSETS AND REPLACE MISC. INTERIOR DOORS."|"1"|"S"|"1956"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"0"|"225,000"|"PROVIDE GFCI RECEPTACLES IN MISC. ROOMS AND REPLACE OLDER VINTAGE PANEL BOARDS."|"1"|"S"|"2002"|"5"|"169,000"|"REPLACE THEATRICAL LIGHTING AND HOUSE LIGHTING IN THE AUDITORIUM. REPLACE VARIOUS INTERIOR AND EXTERIOR FIXTURES."|"1"|"1"|"S"|"2002"|"2"|"188,000"|"REPLACE CLOCK SYSTEM, AUDITORIUM SOUND SYSTEM AND ASSISTIVE LISTENING SYSTEM. UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1985"|"3"|"7,500"|"REPLACE CARPETING IN THE AUDITORIUM."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"E"|"1985"|"5"|"20,000"|"REPLACE QUARRY TILE IN THE KITCHEN AREA."|"1"|"INSTRUCT"|"S"|"1985"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"S"|"1956"|"10"|"0"||"MASONRY"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"1985"|"5"|"75,000"|"MASONRY RESTORATION REQUIRED. REPOINT AND REGROUT FACE BRICK AND PRECAST."|"0"|"MASONRY"|"S"|"2010"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1997"|"5"|"20,000"|"REPLACE MISC. EXTERIOR DOORS AND REPLACE SECURITY SYSTEM MOTION SENSORS."|"1"|"S"|"1985"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1985"|"10"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2010"|"25"|"0"||"1"|"PLASTIC"|"S"|"1993"|"8"|"0"||"1"|"IRON,COPPER"|"S"|"1980"|"1"|"6,000"|"BACKFLOW PREVENTER ON BOILER MAKE-UP WATER."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1959"|"1"|"55,000"|"UPGRADE KITCHEN PLUMBING."|"1"|"NAT_GAS"|"S"|"1985"|"3"|"92,000"|"REPLACE HOT WATER HEATERS, STORAGE TANK, PIPING AND ACCESSORIES."|"1"|"S"|"1956"|"1"|"185,000"|"REPLACE DRINKING FOUNTAINS WITH ADA EWC'S, HOSE BIBB IN GANG LAVS, REPLACE CLASSROOM SINKS AND LAVS, WALL HYDRANT WITH NON-FREEZE VACUUM BREAKER TYPE."|"0"||"1"|"BOILERWATE"||"S"|"2003"|"10"|"0"||"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"1990"|"3"|"46,000"|"REPLACE OFFICE AIR CONDITIONING UNIT."|"1"|"S"|"1956"|"5"|"900,000"|"REPLACE UNIT VENTS, RELIEF HOODS AND AIR HANDLING UNITS."|"1"|"S"|"1956"|"5"|"130,000"|"REPLACE PUMPS AND MISC. PIPING."|"1"|"S"|"1956"|"5"|"46,000"|"INTERNALLY CLEAN DUCTWORK."|"1"|"S"|"2003"|"3"|"190,000"|"UPDATE CONTROLS WITH NEW EQUIPMENT."|"1"|"S"|"2002"|"0"|"6,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION SIGNALS."|"1"|"S"|"2002"|"0"|"6,000"|"PROVIDE ADDITIONAL CODE REQUIRED SMOKE DETECTION."|"1"|"S"|"1956"|"1956"|"271,000"|"INSTALL WET CHEMICAL FIRE HOOD SUPPRESSION SYSTEM IN KITCHEN, INSTALL NEW SPRINKLER SYSTEM FOR STAGE."|"1"|"S"|"2002"|"0"|"40,000"|"PROVIDE ADDITIONAL EXIT SIGNAGE AND ADDITIONAL EMERGENCY LIGHTING."|"1"|"U"|"1957"|"0"|"160,000"|"REPLACE EMERGENCY GENERATOR AND DISTRIBUTION SYSTEM."|"1"|"0"|"35,000"|"PROVIDE ADA ACCESSIBILITY IN THE LOCKER ROOMS."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"1"|"1"|"1"|"1"|"0"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"GOOD"||"5,400,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN ST, WILLIAMSVILLE NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/30/2010 9:44:39 AM| 731|"Oneida City SD"|"25140001"|"Seneca Street Elementary"|"0006"|"08/27/2010"|"436 SENECA ST "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1978"|"30178"|"1"|"1"|"1"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"280"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"280"|"0"|"0"|||"20"|"15500"|"ADMIN,ART,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,REMEDIAL,RSRCEROOM"||"0"||||||"2009"||"0"|"Removed 10k gal underground tank w/ EXCEL funds."|"1"|"MUN_UTILIT"|"S"|"1978"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1978"|"25"|"0"||"1"|"S"|"1978"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1989"|"10"|"0"||"1"|"S"|"1994"|"15"|"0"|"Minor flooding of culvert experienced during severe storms."|"0"||||"0"||"1"|"S"|"1994"|"15"|"0"||"1"|"S"|"1978"|"20"|"0"|"48" box culvert channels Higinbotham Brook through site"|"1"|"SURFACEH2O,OTHER"|"Higinbotham Brook"|"1"|"S"|"1978"|"20"|"0"|"Drainage infrastructure ties into municipal. Discharge @ Higinbotham Brook"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1994"|"5"|"131000"|"Select cutting & patching driveway; seal cracks & re-stripe parking lot"|"1"|"CONCRETE"|"U"|"1994"|"5"|"35000"|"Select replacement of broken curbs/walks"|"1"|"E"|"2009"|"20"|"0"|"Portion of existing playscape upgrade (ADA compliant) w/ EXCEL funds."|"1"|"S"|"1994"|"10"|"0"|"N"|"Open play area only - no full size fields"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1990"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"1978"|"25"|"0"||"1"|"S"|"1994"|"15"|"0"||"0"||||"0"|"Cubbies in classrooms"|"1"|"S"|"S"|"2004"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1993"|"15"|"0"|"Replaced panel boards for technology."|"1"|"S"|"2003"|"25"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 - new district wide VoIP telephone (8yr lifespan); PA (15 yr lifespan)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1994"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1994"|"15"|"0"||"1"|"COMMON"|"S"|"1978"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1978"|"20"|"0"|"Ongoing maintenance (sealing)"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1990"|"25"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1978"|"25"|"0"||"1"|"MASONRY"|"S"|"1978"|"25"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1994"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Roof & skylights replaced w/ EXCEL funds."|"1"|"PLASTIC"|"E"|"2009"|"20"|"0"|"Roof & skylights replaced w/ EXCEL funds."|"1"|"COPPER"|"S"|"2003"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"2003"|"25"|"0"||"1"|"NAT_GAS"|"U"|"1978"|"5"|"35000"|"Recommend replacing gas-fired water heater"|"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"U"|"1998"|"5"|"66000"|"Recommend upgrades"|"1"|"U"|"1998"|"5"|"65000"|"Recommend upgrades"|"0"||||"0"||"1"|"U"|"1998"|"5"|"9000"|"Recommend upgrades"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"|"District is considering building consolidation, which may affect this building"|"341000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 9:44:45 AM| 733|"Sidney CSD"|"12160106"|"Bus Garage"|"5016"|"03/05/2010"|"990 CIRCLE DRIVE "|"SIDNEY "|" 13838"|"ANNUAL"|"12/01/2010"|"2001"|"19844"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus maintenance and storage facility"|"0"|||"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"1"|"8000"|"E"|"2001"|"21"|"0"||"1"|"MUN_UTILIT"|"E"|"2001"|"21"|"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"21"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"31"|"0"||"1"|"S"|"2001"|"21"|"0"||"0"||||"0"||"1"|"S"|"2001"|"41"|"0"||"0"||||"0"||"1"|"MUNI,OTHER"|"swale at roadway"|"0"|"S"|"2001"|"41"|"0"||"0"||||"0"||"1"|"S"|"2001"|"21"|"0"||"0"||||"0"||"1"|"S"|"2001"|"6"|"0"||"1"|"ASPHALT"|"S"|"2001"|"11"|"0"||"1"|"CONCRETE"|"S"|"2001"|"11"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"91"|"0"||"0"|"S"|"2001"|"71"|"0"||"1"|"S"|"2001"|"71"|"0"||"1"|"S"|"2001"|"16"|"0"||"0"||||"0"||"1"|"S"|"S"|"2001"|"26"|"0"||"1"|"S"|"2001"|"66"|"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"31"|"0"||"1"|"S"|"2001"|"16"|"0"||"1"|"1"|"S"|"2001"|"11"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2001"|"11"|"0"||"1"|"COMMON"|"S"|"2001"|"41"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"71"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"66"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2001"|"16"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2001"|"21"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"29"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2001"|"30"|"0"||"1"|"IRON,COPPER"|"S"|"2001"|"30"|"0"||"1"|"OIL"|"S"|"2001"|"5"|"0"||"1"|"S"|"2001"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2001"|"21"|"0"||"1"|"S"|"2001"|"21"|"0"||"0"||||"0"||"1"|"S"|"2001"|"21"|"0"||"0"||||"0"||"1"|"S"|"2001"|"41"|"0"||"1"|"S"|"2001"|"11"|"0"||"1"|"S"|"2001"|"11"|"0"||"1"|"S"|"2001"|"11"|"0"||"0"||||"0"||"1"|"S"|"2001"|"11"|"0"||"1"|"S"|"2001"|"21"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"||"GOOD"||"0"|"S"|"1"|"Bearsch Compeau Knudson Architects and Engineers PC"|"41 Chenango Street, Binghamton, NY 13901"|"607-772-0007"|"sthesier@bckpc.com"|"Steve Thesier"|"033513"|"I ACCEPT"|12/30/2010 9:54:50 AM| 736|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"BLDG #12 (GREENHOUSE) "|"0060"|"05/11/2010"|"1 VOCATIONAL DRIVE "|"PAINTED POST "|" 14870"|"ANNUAL"|"08/01/2011"|"1970"|"3937"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"63"|"9,10,11,12"|"0"|"0"|"0"|"63"|"0"|"0"|||"1"|"3400"|"OTHER"|"Greenhouse"|"0"||||||||"0"||"1"|"WELL"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"10"|"0"|"Foundation consisted of a reinforced floating slab on grade. "|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"5"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1970"|"15"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"10"|"0"||"STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"10"|"0"|"Plastic material for wall construction. "|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2001"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2001"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"0"|||||"0"||"1"|"ELECTRIC"|"S"|"2002"|"12"|"0"||"0"||||"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"17"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"GOOD"||"0"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/30/2010 10:04:40 AM| 737|"Queensbury UFSD"|"63090203"|"Administration"|"1016"|"08/15/2010"|"429 Aviation Road"|"Queensbury"|" 12804"|"ANNUAL"|"01/01/2011"|"1993"|"6750"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"20"|"0"|"Supplied from ES water supply."|"1"|"SITESEPT"|"S"|"2004"|"3"|"10000"|"Replace grinding pump."|"1"|"S"|"2005"|"5"|"50000"|"Convert vendor propane to utility gas."|"1"|"UTIL"|"BELOW"|"S"|"2005"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1993"|"2"|"10000"|"Pavement overlay for parking lot."|"1"|"CONCRETE"|"S"|"1993"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"1"|"0"|"0"|"0"|"S"|"2005"|"5"|"40000"|"Wood structure, slab on grade. Wood sill could not be observed, however framing close proximity to grade indicates that exterior wood framing rotting at grade is likely."|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2005"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"5"|"20000"|"Add light switches."|"1"|"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"5"|"18000"|"Replace poorly patched area at busines office suite"|"1"|"COMMON"|"S"|"2005"|"20"|"0"||"1"|"COMMON"|"S"|"2005"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2005"|"20"|"0"||"WOOD"|"0"|"1"|"Rot was observed but is likely at the sill plate of the perimeter wood wall framing."|"1"|"0"|"0"|"1"|"0"||"S"|"2005"|"1"|"40000"|"Vinyl siding has several open and cracked pieces."|"1"|"METAL"|"S"|"2005"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2005"|"5"|"10000"|"Replace main entrance doors."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2005"|"20"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2005"|"5"|"30000"|"Replace asphalt shingles."|"0"|||||"0"||"1"|"COPPER"|"S"|"2005"|"20"|"0"||"1"|"PVC"|"S"|"2005"|"20"|"0"||"1"|"ELECTRIC"|"S"|"2005"|"5"|"2000"|"Replace 40 gallon LPG water heater with 40 gallon natural gas water heater."|"1"|"E"|"2005"|"10"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2005"|"5"|"40000"|"Replace 2 residential style LPG boilers with natural gas boilers."|"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"10"|"0"|"Residential type split AC system"|"1"|"S"|"2005"|"5"|"40000"|"Upgrade ventilation system"|"1"|"S"|"2005"|"20"|"0"|"See No. 78"|"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1991"|"5"|"10000"|"Upgrade to DDC"|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"5"|"5000"|"Replace emergency lights, exit sign battery packs."|"0"||||"0"||"1"|"0"|"3000"|"Restroom door swings impede full access. Replace doors and reverse the door swing."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"1"|"0"|"0"|"1"|"1"|"SPOT"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"1"||"GOOD"||"288000"|"S"|"1"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"kellis@csarchpc.com"|"Kevin Patrick Ellis"|"03024456"|"I ACCEPT"|12/30/2010 10:06:33 AM| 739|"Oneida City SD"|"25140001"|"Willard F. Prior Elementary"|"0004"|"08/27/2010"|"EAST AVE "|"ONEIDA "|" 13421"|"ANNUAL"|"11/01/2010"|"1957"|"38224"|"1"|"2"|"0"|"PART"|"INSTRUCT,OTHER_ORG"||"260"|"K,1,2,3,4,5,6"|"0"|"0"|"1"|"260"|"0"|"0"|||"25"|"19000"|"ADMIN,ART,CAFE,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,TEACHRSRC"||"0"||||||"2009"||"0"|"Removed 4k gal underground tank w/ EXCEL funds."|"1"|"MUN_UTILIT"|"S"|"1957"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1957"|"25"|"0"||"1"|"S"|"1991"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1991"|"20"|"0"||"1"|"S"|"2010"|"30"|"0"||"0"||||"0"||"1"|"S"|"2010"|"25"|"0"|"Structures in bus loop re-built in 2010"|"0"||||"0"||"0"|"MUNI"||"1"||||"0"|"Drainage infrastructure ties into municipal system"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"25"|"0"|"Parking lots & bus drive reconstructed w/ EXCEL funds"|"1"|"CONCRETE,ASPHALT"|"E"|"2010"|"25"|"0"|"Replaced sidewalks/curbs w/ EXCEL funds"|"1"|"E"|"2009"|"10"|"0"|"Replaced playground equipment w/ EXCEL funds."|"1"|"S"|"2010"|"10"|"0"|"N"|"No formal athletic fields (open lawn only)"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1991"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"S"|"1957"|"25"|"0"|"Ceilings are part of decking system."|"0"||||"0"||"1"|"S"|"S"|"2004"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"E"|"2009"|"50"|"0"|"Replaced branch wiring @ '57 wing; new elect panels @ technology; replaced power distribution panels."|"1"|"S"|"2003"|"20"|"0"||"1"|"1"|"E"|"2009"|"8"|"0"|"2009 new district-wide VoIP telephone (8yr lifespan) & PA (15yr lifespan)"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"25"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"25"|"0"||"1"|"COMMON"|"S"|"2004"|"25"|"0"||"1"|"INSTRUCT"|"S"|"1957"|"20"|"0"|"ongoing maintenance (sealing)"|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1991"|"25"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1991"|"25"|"0"|"Some minor cracks @ exterior panels"|"1"|"MASONRY,CONCRETE"|"E"|"2009"|"25"|"0"|"Brick re-point completed w/ EXCEL funds."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"25"|"0"|"New security system w/ EXCEL funds."|"1"|"S"|"1957"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1957"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Roof & skylights replaced w/ EXCEL funds."|"1"|"PLASTIC"|"E"|"2009"|"20"|"0"|"Roof & skylights replaced w/ EXCEL funds."|"1"|"COPPER"|"S"|"1989"|"25"|"0"||"1"|"IRON,COPPER"|"S"|"1989"|"25"|"0"||"1"|"NAT_GAS"|"S"|"1989"|"10"|"0"||"1"|"S"|"2003"|"25"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2002"|"15"|"0"|"1 new boiler; 1 older unit. Cast iron sectional."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"|"PTAC unit in office. "|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"1991"|"5"|"84000"|"Recommend upgrades"|"1"|"S"|"1991"|"5"|"70000"|"Recommend upgrades"|"1"|"S"|"2003"|"2003"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"|"District is considering building consolidation, which may affect this building"|"154000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 10:08:48 AM| 740|"Island Park UFSD"|"28023102"|"Lincoln Orens Middle School"|"0003"|"06/04/2010"|"Trafalgar Blvd."|"Island Park"|" 11558"|"ANNUAL"|"04/01/2011"|"1962"|"113196"|"2"|"5"|"2"|"DISTRICT"|"INSTRUCT,DIST_ADMIN,OTHER_ORG"||"308"|"5,6,7,8"|"0"|"1"|"1"|"308"|"0"|"0"|||"43"|"34400"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"1"|"1"|"10000"|"0"|"0"|"S"|"1996"|"12"|"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"13"|"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"13"|"0"||"1"|"S"|"1996"|"37"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1962"|"28"|"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"8"|"46000"|"Budget for extension of parking"|"1"|"CONCRETE"|"S"|"2003"|"14"|"0"||"1"|"S"|"1996"|"7"|"26000"|"Budget for repairs"|"1"|"S"|"2009"|"6"|"25550"|"N"|"Budget for fencing"|"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"26"|"0"||"1"|"S"|"1962"|"13"|"1500"|"Budget for fire stopping"|"1"|"S"|"1962"|"13"|"102100"|"Budget for repairs and replacements"|"1"|"S"|"1985"|"6"|"250000"|"Budget for repairs and replacements"|"1"|"S"|"2004"|"8"|"0"||"1"|"S"|"S"|"1962"|"11"|"25000"|"Budget for hardware upgrades and replacements "|"1"|"S"|"1962"|"11"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"1"|"S"|"1962"|"11"|"0"||"1"|"S"|"1962"|"3"|"8000"|"Budget for additional lights in auditorium"|"1"|"1"|"S"|"2002"|"18"|"201000"|"Budget for replacement"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"1962"|"3"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1962"|"3"|"495000"|"Budget for replacements"|"1"|"INSTRUCT"|"S"|"1962"|"3"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"10"|"0"||"PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"26"|"65000"|"Budget for replacements or repairs"|"MASONRY"|"1"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1962"|"26"|"3500"|"Budget for repairs of canopies"|"1"|"MASONRY"|"S"|"1962"|"13"|"0"||"1"|"MASONRY"|"S"|"1962"|"13"|"0"||"S"|"S"|"0"|"1"|"2003"|"0"|"40000 "|"Budget for replacements"|"1"|"S"|"1962"|"13"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1995"|"26"|"89200"|"Budget for upgrading of hardware and replacement of select windows"|"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"S"|"1997"|"8"|"0"||"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1962"|"11"|"0"||"1"|"IRON,COPPER"|"S"|"1962"|"11"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"10"|"0"||"1"|"S"|"1962"|"3"|"800000"|"Budget for renovations of select lavatories and upgrading and repairs of select fixtures"|"0"||"1"|"BOILERSTEA"||"E"|"2009"|"28"|"0"||"1"|"S"|"1996"|"17"|"0"||"1"|"S"|"2010"|"7"|"0"||"1"|"S"|"1997"|"18"|"6000"|"Budget for new exhaust fans for select areas"|"1"|"S"|"2009"|"8"|"540000"|"Budget for steam pipe replacements and repairs of select units "|"1"|"S"|"1962"|"13"|"0"||"1"|"S"|"2009"|"13"|"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1997"|"11"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1962"|"0"|"5000"|"Budget for additional units in select areas"|"1"|"S"|"1962"|"1"|"0"||"1"|"1"|||"GOOD"|"Budget for science lab renovations and new case work and new finshes in select areas"|"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"POOR"||"1"||"0"|"1"|"0"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"COMMSYS,FIREALARM,LIGHTING"|"FULL"||"1"||"GOOD"||"3073850"|"S"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Douglas H Adil RA"|"021836"|"i accept"|12/30/2010 10:17:44 AM| 742|"Duanesburg CSD"|"53010104"|"Elementary School"|"0002"|"08/20/2010"|"165 Chadwick Road "|"DELANSON "|" 12053"|"ANNUAL"|"06/01/2011"|"1953"|"58,565"|"1"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"398"|"K,1,2,3,4,5"|"0"|"1"|"1"|"398"|"0"|"0"|||"20"|"16,210"|"ADMIN,ART,GYM,KITCHEN,LIBBRARY,OTHER"|"Cafetorium"|"1"|"0"|"0"|"1"|"10,000"|"S"|"1996"|"16"|"0"||"1"|"WELL"|"S"|"1995"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"18"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1953"|"10"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"E"|"2005"|"100"|"0"||"1"|"S"|"2005"|"45"|"0"||"0"||||"0"||"1"|"OTHER"|"Seasonal wetland"|"0"|"E"|"1953"|"100"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"2"|"570,000"|"Issues with safety and physical deterioration."|"1"|"CONCRETE"|"U"|"2005"|"2"|"170,000"|"Sidewalks are uneven"|"1"|"S"|"1982"|"43"|"0"||"0"|"U"|"1953"|"0"|"350,000"|"N"|"Turf and track are deteriorated and inadequate."|"RECONCRETE"|"0"|"0"|"0"|"1"|"0"|"0"|"U"|"1953"|"2"|"39,000"|"Crawl spaces have water in them."|"1"|"S"|"1983"|"23"|"0"||"1"|"S"|"1983"|"23"|"0"||"1"|"S"|"1983"|"12"|"0"||"1"|"S"|"1983"|"70"|"0"||"1"|"S"|"S"|"1953"|"12"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1983"|"23"|"0"||"1"|"S"|"1983"|"5"|"0"||"1"|"1"|"S"|"1983"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1983"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1983"|"12"|"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1953"|"7"|"0"|"Wood floor in gym and cafetorium is servicable."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1953"|"47"|"0"||"MASONRY"|"0"|"0"|"Condensation"|"0"|"0"|"0"|"1"|"0"|"Condensation"|"U"|"1983"|"0"|"60,000"|"Overhanging soffits have problem with interior condensation."|"1"|"MASONRY"|"S"|"1953"|"5"|"0"||"1"|"MASONRY"|"S"|"2005"|"5"|"0"||"E"|"E"|"0"|"1"|"1983"|"42"|"0"||"1"|"S"|"1983"|"42"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"Y"|"1983"|"2"|"55,000"|"Glazing seals are broken and units are poor quality."|"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"0"|"Roof age"|"U"|"1981"|"0"|"961,000"|"Sprayed-on roof is at end of lifecycle."|"0"|||||"0"||"1"|"COPPER"|"S"|"1953"|"7"|"0"||"1"|"IRON,COPPER"|"S"|"1953"|"7"|"0"||"1"|"OIL"|"S"|"1953"|"7"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"OTHER"|"1"|"BOILERWATE"||"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"S"|"2005"|"15"|"0"|"Partial coverage by split system only."|"1"|"S"|"2005"|"15"|"0"|"Prtial coverage by split system only."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"15"|"0"|"Limited coverage only."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"2005"|"35"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1953"|"1953"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"1"|"CLASSROOMS,HALLWAYS"||"1"|"1"|"115,000"|"Moisture condition in perimeter soffits needs remediation."|"0"|"0"|"0"|"0"|"1"|"0"|"POOR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"|"0"|"1"||"GOOD"||"3,200,000"|"U"|"1"|"Synthesis Architects, LLP"|"162 Jay Street, Schenectady, New York 12305"|"518-370-1576"|"rdefranco@synthesisllp.com"|"John Senisi"|"020640"|"I ACCEPT"|12/30/2010 10:34:18 AM| 743|"Kenmore-Tonawanda UFSD"|"14260103"|"Kenmore Middle School"|"0017"|"09/10/2010"|"155 DELAWARE RD "|"KENMORE "|" 14217"|"ANNUAL"|"07/01/2011"|"1923"|"176,145"|"4"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"653"|"6,7,8"|"0"|"0"|"1"|"653"|"0"|"0"|||"43"|"28,800"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"18,000"|"NF"|"1995"|"1"|"179,000"|"Remove underground tank, piping, accessories, estimated 500 cu.yds. of contaminated soil and 1,000 gallons of unused oil."|"1"|"MUN_UTILIT"|"S"|"2000"|"1"|"242,000"|"Relocate water meters, backflow preventers and fire hydrant away from building. New backflow preventer and external enclosure for athletic fields."|"1"|"MUN_UTILIT"|"S"|"1956"|"12"|"0"||"1"|"S"|"1956"|"1"|"69,000"|"Install emergency gas shutoff system in Science rooms and Home Economics rooms."|"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"1995"|"5"|"15,000"|"Regrade at existing catch basins."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"15"|"0"||"1"|"CONCRETE"|"S"|"1995"|"5"|"50,000"|"Replace deteriorating and broken concrete sidewalks."|"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"15"|"0"||"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"5"|"150,000"|"Replace miscellaneous Z-Spline ceilings with new A.C.T. ceiling system."|"1"|"S"|"1956"|"5"|"600,000"|"Replace all Corridor lockers and Locker Room athletic lockers."|"1"|"S"|"S"|"1995"|"5"|"200,000"|"Replace hardware with new lever locksets and closers. Replace interior stairhall doors."|"1"|"S"|"1956"|"2"|"100,000"|"Replace risers/treads with new supports, install new concrete and rubber tread/riser covers."|"1"|"E"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"0"|"294,000"|"Provide GFCI receptacles, emergency shutdowns and replace older vintage panel boards."|"1"|"S"|"2002"|"5"|"47,000"|"Replace various old interior and exterior fixtures."|"1"|"1"|"U"|"2003"|"0"|"410,000"|"Replace public address (PA) system, clock system and sound system in Auditorium. Upgrade telephone system, lower telephone sets to meet A.D.A. requirements. Install new assistive listening systems for Gymnasium."|"1"|"S"|"2000"|"1"|"69,000"|"Replace hot water heater and circulation pipes."|"1"|"INSTRUCT,COMMON"|"S"|"1995"|"5"|"125,000"|"Replace carpet in Auditorium, Guidance areas and Library."|"1"|"INSTRUCT"|"S"|"1995"|"10"|"0"||"1"|"COMMON"|"S"|"1995"|"5"|"150,000"|"Replace ceramic tile on Pool deck and miscellaneous Toilet Rooms."|"1"|"INSTRUCT,COMMON"|"S"|"1956"|"5"|"250,000"|"Replace wood floors in Gymnasium, Cafeteria and miscellaneous Classrooms."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"5"|"150,000"|"Masonry restoration required. Replace miscellaneous brick, repoint and regrout masonry."|"1"|"MASONRY"|"S"|"1956"|"5"|"200,000"|"Replace cap with new S.S. cap, new liner and breeching for hot water tank, replace brick, repoint and regrout masonry."|"1"|"MASONRY"|"S"|"1956"|"10"|"0"||"S"|"S"|"0"|"1"|"2005"|"5"|"25,000"|"Replace security system motion sensors."|"1"|"S"|"2005"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1973"|"5"|"2,875,000"|"Replace exterior windows in the entire building."|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Delaminating membrane"|"S"|"1998"|"1"|"125,000"|"Replace delaminating membrane with new roofing system on the original building."|"1"|"PLASTIC"|"S"|"1998"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1956"|"1"|"6,000"|"Install new backflow preventer on boiler make-up water."|"1"|"IRON,GALVANIZED,COPPER,LEAD"|"S"|"1956"|"1"|"11,500"|"Replace existing grease trap."|"1"|"NAT_GAS"|"S"|"2000"|"5"|"138,000"|"Replace hot water heater, storage tank, piping and accessories."|"1"|"S"|"2004"|"1"|"145,000"|"Renovate Locker Rooms for A.D.A. accessibility. Replace drinking fountains with A.D.A. electric water coolers, new hose bibbs in gang lavatories."|"1"|"VAV"|"1"|"BOILERSTEA"||"S"|"2002"|"3"|"460,000"|"Replace boilers and accessories."|"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"U"|"2002"|"0"|"1,610,000"|"Replace unit ventilators, exhaust fans and relief hoods."|"1"|"S"|"1956"|"3"|"200,000"|"Replace boiler feed unit and miscellaneous piping."|"1"|"S"|"1956"|"5"|"70,000"|"Internally clean ductwork."|"1"|"S"|"2002"|"5"|"260,000"|"Update controls on new equipment."|"1"|"S"|"2003"|"0"|"60,000"|"Provide additional code required notification signals."|"1"|"S"|"2003"|"0"|"21,000"|"Provide additional code required smoke detection."|"1"|"S"|"1995"|"1995"|"287,500"|"Stage reconstruction work, install new sprinkler system for Stage."|"1"|"S"|"2003"|"0"|"156,000"|"Provide additional exit signage, and interior and exterior emergency lighting."|"1"|"U"|"1951"|"0"|"178,000"|"Replace emergency generator and distribution system."|"1"|"0"|"75,000"|"Provide A.D.A. accessibility in Locker Rooms."|"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"12,800,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street Williamsville NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 10:34:58 AM| 744|"Riverhead CSD"|"58060204"|"Administration Building"|"1002"|"08/20/2010"|"700 Osborne Avenue"|"Riverhead"|" 11901"|"ANNUAL"|"05/01/2011"|"1968"|"9750"|"1"|"0"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|"OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"8"|"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"8"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1968"|"8"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"1968"|"5"|"96,000"|"Repave parking lot (7,000 sf) & pave gravel lot (12,000 sf)."|"1"|"CONCRETE"|"S"|"1968"|"8"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"1"|"S"|"1968"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1968"|"10"|"4,000"|"Install lever handles for ADA compliance."|"1"|"S"|"1968"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"15"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"1"|"S"|"1968"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2007"|"10"|"0"|"Replace areas not previously replaced."|"1"|"COMMON"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"OTHER"|"Wood deck on wood joists over steel beams"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"15"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1998"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1968"|"10"|"0"||"WOODONWOOD"|"SINGLEPLY,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"6"|"0"|"Plan for replacement of shingle roof."|"0"|||||"0"||"1"|"COPPER"|"S"|"1968"|"8"|"0"||"1"|"IRON"|"S"|"1968"|"8"|"0"||"1"|"ELECTRIC"|"S"|"2000"|"10"|"0"||"1"|"S"|"1968"|"8"|"1,250"|"Provide vacuum breaker on slop sink."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1968"|"8"|"0"||"1"|"S"|"1968"|"8"|"0"||"1"|"S"|"1968"|"8"|"0"||"1"|"S"|"1968"|"5"|"192,600"|"Provide fresh air for all areas."|"0"||||"0"||"1"|"S"|"1968"|"8"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"2009"|"19"|"0"||"1"|"S"|"2009"|"19"|"0"||"0"||||"0"||"1"|"S"|"1968"|"5"|"0"||"0"||||"0"||"0"|"1"|"4,000"|"Replace door knobs with lever type."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"0"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"0"|"0"|"FAIR"|"Expand to bring PPS and Special Education offices into this building"|"297,850"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchgoue, NY 11772"|"631-475-0349"|"seeba@bbsarch.com"|"Frederick W. Seeba, PE"|"068018"|"I ACCEPT"|12/30/2010 10:40:12 AM| 745|"Avoca CSD"|"57020104"|"Main Bldg"|"0002"|"11/18/2009"|"17-29 Oliver St."|"Avoca,N.Y."|" 14809"|"ANNUAL"|"08/01/2011"|"1922"|"150070"|"3"|"9"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"607"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"607"|"0"|"0"|||"31"|"26170"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2000"|"30"|"0"||"1"|"OTHER"|"E"|"2000"|"20"|"0"|"On-site septic treatment system."|"1"|"E"|"2007"|"35"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2000"|"30"|"30000"|"Provide site lighting in staff parking lot at rear of building."|"1"|"S"|"2007"|"30"|"0"||"0"||||"0"||"1"|"S"|"2007"|"25"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"SURFACEH2O"||"0"|"S"|"1990"|"15"|"0"|"Outfall under DEC jurisdiction."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"10"|"500000"|"Remove replace north parking lot $200,000; remove replace south parking lot $150,000; remove replace servie areas not redone $30,000; remove replace bus loop to south $120,000."|"1"|"CONCRETE,ASPHALT"|"S"|"2000"|"10"|"0"|"See Item No 65."|"1"|"E"|"2008"|"15"|"0"||"1"|"S"|"1985"|"5"|"750000"|"N"|"prkng exhbt flds ADA wlks $100,000; 600 seat blchr exhbt flds ($150K) perm toilt fac w 2 fxtrs per gender ($150K) inc septic ($50K) and water ($50K) $400,000; rplc lgtg bsktball courts; new lgtg at tennis courts $150,000; Rplc baseball dugouts $100,000."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"75"|"0"||"1"|"S"|"2010"|"75"|"0"||"1"|"S"|"1938"|"40"|"2200"|"Minor plastic cracks in some clsrms and corr walls $2,000; Brkn wall tile at south end vest in 200 addn $200."|"1"|"S"|"2009"|"10"|"2000"|"Food svce area in caf has nonwashable ceiling tiles. Rplc w scrubbable tile to comply with health code. $2000."|"0"|"S"|"2002"|"3"|"2000"|"Some infill panels need rplc w perm wall at HS lockers $2000."|"1"|"S"|"U"|"2002"|"10"|"1700"|"Inst closers on so stairwell doors. Adjust hinges for pos closure on corr doors outside Room 217 and 230. Door closer failing in no stair door near Room 229 repair or replace."|"1"|"S"|"2009"|"50"|"108100"|"Strwl so end corr nr Rm 230 not prvde for rtd enc diff to rctfy bsd on loc avl area. Crct if area is renov $100,000; hnd rl ext neded at Str S1 S2 S4 S6 S7. diff to rctfy due to extg cond. Str S6 rpl exp jnt at thrshld plte. Repnt rlngs pr allow $8,100."|"1"|"S"|"1987"|"10"|"0"||"1"|"1"|"S"|"2008"|"28"|"16000"|"Rpl pwr pnl PPA4 and assoc feeder first fl Corr C12 beyond useful life $8000; Rpl FPE pwr pnl in OT/PT 131 and assoc feeder beyond useful life $8,000."|"1"|"S"|"2000"|"10"|"165900"|"Rpl lghtg 1987 clsrms. Rpl T12 lghtg num clsrms. Add occ snsrs 1987 clsrm wing. Seal caulk old lght cov ext wall abv west ent dr by lckr rms cov elec box ext abv supt off $130900; Rpl metal hallide lghtg multiprps rm 120A w high perf T8 lghtg $35000"|"1"|"1"|"S"|"2000"|"10"|"0"|"mstr clck failing rplc complete sys w Wireless GPS mstr clck sys $30000; Aud Snd reinforcemet sys has no ADA hear assist dvcs prov hear assist $6500"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"31700"|"Rpl flr tls Room 220 $200; VCT rplc Rms 232 233 234 238 and 240 6055 sf at $5 sf $31,000; Rpr crk vynl flr no end of 2000 addn $500"|"0"|"COMMON"|"S"|"2008"|"40"|"720"|"Repair dmgd tile base molding in 207. $720"|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"20"|"2640"|"Bsmnt sev wood walls withing area used for strg. Remve walls or rplce walls w rated partitions. $2640"|"SLABGRADE,CONCRMETAL,OTHER"|"struct slab w strcut clay tile. conc metal mesh metal joists"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2010"|"75"|"0"||"MASONRY,STEEL"|"0"|"0"|"2nd flr wndw lntls rusting at 1938 bldg; CMU cracks 1st and 2nd flr wndws 2000 addn"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"75"|"0"||"1"|"METAL"|"E"|"2010"|"75"|"0"||"1"|"MASONRY"|"S"|"2010"|"75"|"0"||"S"|"S"|"0"|"1"|"2007"|"15"|"1500"|"Not all threstholds ADA cmplnt. Install ADA cmplnt thresholds at 2000 addns. $1500"|"1"|"S"|"2009"|"2"|"50000"|"Conc rplcmnt needed at bus loop stair and ramp at so end of bldg. $50,000"|"0"|||||"0"||"1"|"ALUMINUM,VINYL"|"S"|"Y"|"2009"|"20"|"2200"|"Wndw rescue in Rm 233 very high and req ladder for egress. Install ladder. $2200"|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"35000"|"Rof deck mltiprps room poor cond Recon and patch roof matrls $30000; Ponding area above Cafeteria Add roof drain or tapered insulation $5000."|"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"COPPER"|"S"|"2007"|"37"|"10000"|"Replace valves in 1965 wing. $10000"|"1"|"IRON"|"S"|"2007"|"37"|"5000"|"Add roof drains at pondign locations over Cafeteria $5000"|"1"|"NAT_GAS"|"S"|"1995"|"5"|"15000"|"Replace water heater in old boiler room $15000"|"1"|"E"|"2007"|"27"|"0"|"Rplc 2 outdated drink fount 2nd flr nr elem wing and 2nd flr nr strs by gym $3,500; upgrade toilet rms in 1965 wing for ADA compliance $10000"|"0"||"1"|"BOILERWATE"||"E"|"2007"|"20"|"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"E"|"2007"|"15"|"6000"|"Electric Room 239 is overheating and requires AC. $6000"|"1"|"S"|"2007"|"20"|"64000"|"1989 clsrm wing UVs are in need of replace 9 clsrms $54000.; kitchen dishwasher hood ineffective. Replae with approp hood and fan $10000"|"1"|"S"|"2007"|"20"|"10000"|"Repair minor leaks at fittings and valves in crawlspace insulate all hangers and shields $10000"|"1"|"S"|"2007"|"20"|"0"||"1"|"S"|"2007"|"15"|"27000"|"Integrate 1987 clsrm wing controld into bldg energy mgmt control sys. $12000; relocate vavles and integrate into mgmt control sys $15000"|"1"|"S"|"2000"|"10"|"45500"|"Prov aud vis notify dev in all occ spcs. $30000; Relct and reinstl all man pull statns to comply w codes $3500; Replc all 24v mag hold opns thru bldg failing $12000"|"1"|"S"|"2000"|"10"|"1500"|"Add digital comm to FACp for connect to fire dept $1500"|"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"2008"|"15"|"0"|"Replc exit sign with LED fxtr $300; RedCross batt pwr lght not satisf See item 86. Ext EM lgt to be code compliant See item 86. Replc exit fxtr with new LED eix fxtr $550"|"0"||||"0"||"1"|"1"|"36000"|"Tlt Rms TR3 TR4 TR5 not access make access $30000; ADA signage not prevalent thru school $5000; Fire ext signage not prevalent thru school $1000"|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"0"||"FULL"|"0"|"1"||"GOOD"||"4244513"|"S"|"0"|"Tetra Tech Architects and Engineers"|"10 Brown Road"|"607-277-7100"|"info@tetratech.com"|"Susan Mehr"|"018634"|"I ACCEPT"|12/30/2010 10:40:15 AM| 746|"Kenmore-Tonawanda UFSD"|"14260103"|"Roosevelt Elementary"|"0021"|"08/11/2010"|"283 WASHINGTON AVE "|"KENMORE "|" 14217"|"ANNUAL"|"07/01/2011"|"1927"|"70988"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"348"|"Pre-K,K,1,2,3,4,5"|"0"|"0"|"1"|"348"|"0"|"0"|||"14"|"10550"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"10,000"|"NF"|"1950"|"1"|"156,000"|"REMOVE UNDERGROUND TANK, PIPING, ACCESSORIES, EST 550 CU. YDS. OF CONTAMINATED SOIL AND 1000 GALLONS OF UNUSED OIL."|"1"|"MUN_UTILIT"|"S"|"1990"|"1"|"90,000"|"BACKFLOW PREVENTER AND EXTERNAL ENCLOSURE FOR DOMESTIC WATER."|"1"|"MUN_UTILIT"|"S"|"1927"|"12"|"0"||"1"|"S"|"1927"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"20"|"0"||"1"|"S"|"1927"|"5"|"15,000"|"REPIPE SUMP PUMP DISCHARGE IN GYM TO STORM SEWER."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"7"|"0"||"1"|"CONCRETE"|"S"|"1997"|"7"|"0"||"1"|"S"|"2002"|"17"|"0"||"1"|"S"|"1997"|"5"|"20,000"|"N"|"REGRADE EXISTING ATHLETIC FIELD"|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1935"|"10"|"0"||"1"|"S"|"1935"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"3"|"75,000"|"REPLACE CEILING IN THE CORRIDORS AND KITCHEN AREA."|"1"|"S"|"1997"|"5"|"70,000"|"REPLACE LOCKERS IN THE BOYS AND GIRLS LOCKER ROOM."|"1"|"S"|"S"|"2004"|"3"|"20,000"|"REPLACE HARDWARE WITH NEW LEVER LOCKSETS."|"1"|"S"|"1935"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"1"|"80,000"|"PROVIDE GFCI RECEPTACLES, ADD BRANCH CIRCUITS, REPLACE OLD WIRING."|"1"|"S"|"2002"|"5"|"165,000"|"REPLACE AUDITORIUM LIGHTING AND STAGE DIMMING SYSTEM AND REPLACE MISC. OLD LIGHTING FIXTURES."|"1"|"1"|"S"|"2002"|"1"|"175,000"|"REPLACE CLOCK SYSTEM, AUDITORIUM SOUND SYSTEM AND ASSISTIVE LISTENING SYSTEM UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"1975"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1935"|"3"|"80,000"|"REPLACE WOOD FLOOR IN GYMNASIUM."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"S"|"1935"|"10"|"0"||"MASONRY"|"0"|"0"|"NONE"|"1"|"1"|"0"|"0"|"0"|"NONE"|"S"|"1997"|"2"|"100,000"|"MASONRY RESTORATION REQUIRED. REPOINT, REGROUT, AND REPLACE BRICK."|"1"|"MASONRY"|"S"|"2010"|"25"|"0"||"1"|"MASONRY"|"S"|"2010"|"20"|"0"||"S"|"S"|"0"|"0"|"2004"|"20"|"0"||"1"|"S"|"1997"|"7"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"12"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2010"|"25"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1983"|"1"|"6,000"|"INSTALL BACKFLOW PREVENTER ON BOILER MAKE-UP WATER."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1935"|"1"|"60,000"|"UPGRADE KITCHEN PLUMBING INCLUDING REPLACEMENT OF THE GREASE TRAP."|"1"|"NAT_GAS"|"S"|"2003"|"5"|"87,000"|"REPLACE HOT WATER HEATERS, STORAGE TANKS, PIPING AND ACCESSORIES."|"1"|"S"|"2004"|"1"|"58,000"|"REPLACE ORIGINAL FIXTURE TRIM."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1990"|"5"|"300,000"|"REPLACE BOILERS AND ACCESSORIES."|"1"|"S"|"1990"|"6"|"0"||"1"|"S"|"1995"|"10"|"0"||"1"|"U"|"2003"|"3"|"830,000"|"REPLACE/ADD UNIT VENTS, RELIEF HOODS AND EXHAUST FANS."|"1"|"U"|"1927"|"3"|"200,000"|"REPLACE BOILER FEED UNITS, MISC. PIPING AND RADIATION."|"1"|"S"|"1927"|"5"|"60,000"|"INTERNALLY CLEAN DUCTWORK."|"1"|"S"|"2003"|"3"|"205,000"|"UPDATE CONTROLS WITH NEW EQUIPMENT."|"1"|"S"|"2002"|"0"|"7,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION SIGNALS."|"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED SMOKE DETECTION."|"1"|"S"|"2002"|"2002"|"253,000"|"RECONSTRUCTION WORK AT STAGE, INSTALL NEW SPRINKLER SYSTEM FOR STAGE."|"1"|"S"|"2002"|"0"|"70,000"|"PROVIDE ADDITIONAL EXIT SIGNAGE, INTERIOR AND EXTERIOR EMERGENCY LIGHTING."|"1"|"U"|"1980"|"0"|"160,000"|"REPLACE EMERGENCY GENERATOR AND DISTRIBUTION SYSTEM."|"1"|"0"|"50,000"|"PROVIDE ADA ACCESSIBILITY IN LOCKER ROOMS AND ADDITIONAL ENTRANCE."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"4,750,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN STREET, WILLIAMSVILLE NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/30/2010 11:00:14 AM| 747|"Queensbury UFSD"|"63090203"|"WM Barton Intermediate School"|"0019"|"08/15/2010"|"425 Aviation Road"|"Queensbury"|" 12804"|"ANNUAL"|"01/01/2011"|"1998"|"71850"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"533"|"4,5"|"0"|"1"|"1"|"533"|"0"|"0"|||"24"|"20416"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"20"|"0"||"1"|"SITESEPT"|"S"|"1998"|"5"|"150000"|"Septic system replacement"|"1"|"S"|"1998"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"0"||||"0"||"1"|"S"|"1998"|"8"|"0"||"0"||||"0"||"0"|||||||"0"||"1"|"S"|"1998"|"5"|"100000"|"To mitigate stormwater ponding at curb side in front of building."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"3"|"90000"|"Pavement overlay at bus drop off and two parking lots near intermediate school."|"1"|"CONCRETE"|"S"|"1998"|"5"|"80000"|"Additional sidewalk to playground."|"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"5"|"100000"|"N"|"Clear additional woods for playfields."|"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"20"|"0"|"Stepped crack in masonry on north wall."|"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"S"|"1998"|"20"|"0"||"1"|"E"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"1"|"E"|"1998"|"20"|"0"||"1"|"E"|"1998"|"10"|"0"||"1"|"1"|"E"|"1998"|"10"|"0"|"Manufacturer - Telcor"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1998"|"5"|"150000"|"All carpeting"|"1"|"INSTRUCT,COMMON"|"S"|"1998"|"20"|"0"||"1"|"COMMON"|"S"|"1998"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1998"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1998"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1998"|"5"|"50000"|"Repair concrete bases at entrance canopy."|"1"|"METAL"|"S"|"1998"|"20"|"0"||"1"|"MASONRY"|"S"|"2010"|"20"|"0"||"S"|"S"|"1"|"1"|"1998"|"5"|"30000"|"Replace main entrance doors."|"1"|"S"|"1998"|"2"|"25000"|"Loading dock ramp, steps, heaved."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1998"|"18"|"0"||"METONMET,OTHER"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Glass block in stair well showing signs of crackings, needs further investigation"|"S"|"2010"|"5"|"30000"||"1"|"GLASS"|"S"|"1998"|"18"|"0"||"1"|"COPPER"|"S"|"1998"|"5"|"20000"|"Isolation valves replacement - 200"|"1"|"IRON,GALVANIZED"|"S"|"1998"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"5"|"5000"|"Replace Art room sink and make faucets ADA"|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"2010"|"15"|"0"||"1"|"S"|"1998"|"5"|"100000"|"Upgrade kitchen hood for additional kitchen equipment"|"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"20"|"0"||"1"|"S"|"1998"|"5"|"50000"|"Upgrade entire building to updated DDC"|"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"1998"|"5"|"20000"|"Replace emergency lights, exit sign battery packs."|"0"||||"0"||"1"|"0"|"5000"|"See Art sink"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"1"|"SPOT"|"0"|"0"||||"1"|"0"||"WARMING"||"0"|"0"|"GOOD"||"1000000"|"S"|"1"|"CSArch"|"40 Beaver St, Albany, NY 12207"|"518-463-8068"|"kellis@csarchpc.com"|"Kevin Patrick Ellis"|"03024456"|"I ACCEPT"|12/30/2010 11:01:37 AM| 748|"Kenmore-Tonawanda UFSD"|"14260103"|"Lindbergh Elementary School"|"0024"|"07/12/2010"|"184 IRVING TERRACE "|"KENMORE "|" 14223"|"ANNUAL"|"07/01/2011"|"1928"|"81,885"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"494"|"K,1,2,3,4,5"|"0"|"1"|"0"|"494"|"0"|"0"|||"24"|"17,400"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"6,000"|"NF"|"1950"|"1"|"138,000"|"Remove underground tank, piping, accessories, est. 550 cu. yd. of contaminated soil and 1000 gallons of unused oil."|"1"|"MUN_UTILIT"|"S"|"1950"|"1"|"127,000"|"Backflow preventer & external enclosure for domestic water and athletic field."|"1"|"MUN_UTILIT"|"S"|"1950"|"10"|"0"||"1"|"S"|"1950"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1997"|"20"|"0"||"1"|"S"|"1928"|"6"|"0"||"0"||||"0"||"1"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1997"|"8"|"0"||"1"|"CONCRETE"|"S"|"1997"|"8"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"1997"|"18"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1928"|"15"|"0"||"1"|"S"|"1950"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"5"|"40,000"|"Replace ceilings in the Main Office Area and Corridors."|"1"|"S"|"1997"|"18"|"0"||"1"|"S"|"S"|"1997"|"2"|"100,000"|"Replace hardware with lever locksets & closers. Replace misc. interior doors and new doors at stairhalls."|"1"|"S"|"1997"|"18"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"2"|"65,000"|"Replace old building wiring."|"1"|"S"|"2002"|"5"|"135,000"|"Replace Auditorium theatrical lighting system & house lighting and various building lighting."|"1"|"1"|"S"|"2002"|"2"|"195,000"|"Replace clock system, Auditorium sound system & assistive listening system. Upgrade telephone system."|"0"||||"0"||"1"|"COMMON"|"S"|"1997"|"3"|"15,000"|"Replace carpet in the Auditorium and Main Office Areas."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"1997"|"3"|"20,000"|"Replace ceramic tile in the locker rooms."|"1"|"INSTRUCT,COMMON"|"S"|"1997"|"8"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1928"|"18"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1997"|"3"|"200,000"|"Masonry Restoration Required. Clean & replace precast and repoint existing masonry."|"1"|"MASONRY"|"S"|"1950"|"5"|"85,000"|"Replace with stainless steel cap & liner, replace reinforcing bands, replace & repoint brick."|"1"|"MASONRY"|"S"|"1997"|"8"|"0"||"S"|"S"|"0"|"1"|"1976"|"5"|"100,000"|"Replace exterior doors and replace security system motion sensors."|"1"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1950"|"3"|"1,400,000"|"Replace all windows on the entire building."|"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1995"|"1"|"6,000"|"Install Backflow preventer on Boiler make-up water."|"1"|"IRON"|"S"|"1995"|"1"|"120,000"|"Rod out / power flush Kitchen sanitary sewers and drains in the building. Upgrade Kitchen plumbing including replacement of grease trap."|"1"|"NAT_GAS"|"S"|"2001"|"1"|"40,000"|"Replace 115 gallon hot water storage tank and add mixing valve. Remove abandoned hot water storage tank & accessories."|"1"|"S"|"1995"|"1"|"40,000"|"Install ADA Electric Water Coolers, Faucets with vacuum breaker on service sinks, replace wall hydrant with non-freeze integral vacuum breaker type."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"1983"|"5"|"300,000"|"Replace Boilers, piping and accessories."|"1"|"S"|"1990"|"6"|"0"||"1"|"S"|"2004"|"6"|"0"||"1"|"S"|"2004"|"5"|"1,170,000"|"Replace unit vents, exhaust fans, relief hoods and air handling units."|"1"|"S"|"2004"|"3"|"235,000"|"Replace Boiler Feed Unit and misc. piping."|"1"|"S"|"2004"|"5"|"70,000"|"Internally Clean Ductwork."|"1"|"S"|"2004"|"3"|"230,000"|"Update Controls with new equipment."|"1"|"S"|"2002"|"0"|"30,000"|"Provide additional code required notification signals."|"1"|"S"|"2002"|"0"|"16,000"|"Provide additional code required smoke detection."|"1"|"S"|"2003"|"2003"|"253,000"|"Reconstruction Work at Stage - install new sprinkler system for stage."|"1"|"S"|"2002"|"0"|"67,000"|"Provide additional exit signage and various building emergency lighting."|"1"|"U"|"1980"|"0"|"160,000"|"Replace Emergency Generator and Distribution System."|"1"|"0"|"50,000"|"Provide ADA accessibility in the locker rooms and additional entrance."|"FAIR"||"FAIR"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"7,310,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 11:02:19 AM| 749|"Pavilion CSD"|"18120104"|"Elementary School"|"0004"|"11/02/2010"|"7014 Big Tree Road"|"Pavilion"|" 14525"|"ANNUAL"|"08/01/2011"|"1975"|"76,788"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"355"|"K,1,2,3,4,5"|"0"|"1"|"0"|"355"|"0"|"0"|||"20"|"17,300"|"ADMIN,ART,AV,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"40"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"40"|"0"||"1"|"S"|"2000"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"30"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2000"|"10"|"15,000"|"Drainage improvements."|"1"|"CONCRETE"|"S"|"2000"|"20"|"0"|"Replace concrete at entrance."|"0"||||"0"||"1"|"S"|"1980"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2000"|"50"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"35"|"48,000"|"Install ceramic tile in corridor walls."|"1"|"S"|"2000"|"30"|"0"||"0"||||"0"||"1"|"S"|"S"|"2000"|"30"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"1"|"S"|"2000"|"20"|"16,000"|"Replace panel boards."|"1"|"S"|"2000"|"10"|"52,000"|"Add occupancy sensors and replace gym lighting."|"1"|"1"|"S"|"2000"|"10"|"24,000"|"Add PA speakers and cameras."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"5"|"8,000"|"Replace carpet in offices."|"1"|"INSTRUCT,COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"2000"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"30"|"25,000"|"Masonry restoration."|"1"|"MASONRY,METAL"|"S"|"2000"|"30"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2000"|"30"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"25"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"0"||"1"|"PLASTIC"|"S"|"2000"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2002"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"2002"|"10"|"6,000"|"Add eyewash in Boiler Room and replace faucets."|"1"|"CV,DD_MZ"|"1"|"BOILERWATE"||"S"|"2000"|"20"|"7,500"|"Add gas detection system to Boiler Room."|"1"|"S"|"2000"|"25"|"0"|"Re-pipe gas to generator direct from meter."|"1"|"S"|"2000"|"15"|"15,000"|"Add A/C for Server Room."|"1"|"S"|"2000"|"20"|"28,000"|"UPgrade exhaust and ventilation systems."|"1"|"S"|"2000"|"20"|"5,000"|"Repair pipe leaks in Boiler Room."|"1"|"S"|"2000"|"25"|"5,000"|"Insulate combustion air ductwork and clean ductwork."|"1"|"S"|"2000"|"15"|"120,000"|"Upgrade and extend DDC system."|"1"|"S"|"2000"|"10"|"3,000"|"Expand coverage."|"1"|"S"|"2000"|"10"|"3,000"|"Expand coverage."|"0"||||"0"||"1"|"S"|"2000"|"10"|"10,000"|"Add discharge lighting."|"1"|"S"|"2000"|"20"|"60,000"|"Add two-hour rated room and generator and segregate life safety loads."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,COOKING,FIREALARM,SUMPPUMP,SCURITYSYS,LIGHTING"|"WARMING"||"1"||"GOOD"||"485,500"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/30/2010 11:02:47 AM| 750|"Chittenango CSD"|"25160106"|"High School"|"0001"|"07/01/2010"|"150 Genesee Street"|"Chittenango"|" 13037"|"ANNUAL"|"09/01/2011"|"1951"|"174,297"|"2"|"9"|"1"|"DISTRICT"|"INSTRUCT"||"783"|"9,10,11,12"|"0"|"1"|"1"|"783"|"0"|"0"|||"50"|"39,500"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"1"|"1000"|"0"|"0"|"S"|"1995"|"2"|"0"||"1"|"MUN_UTILIT"|"S"|"1996"|"40"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"45"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"30"|"0"||"0"||||"0"||"1"|"S"|"2005"|"15"|"5,000"|"Drainage swale adjacent to north parking area to be expanded 40 lf x 20 lf wide to allow 8 inch culvert to drain properly."|"1"|"U"|"1995"|"5"|"16,500"|"Replace 4 drain inlets at north lot and remove debris from remaining drain inlets."|"1"|"S"|"2005"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"1"|"U"|"2005"|"15"|"1,000"|"Pipe at the low point of the basin adjacent to the concession building must be cleared of debris to achieve designed storm water drainage."|"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"5"|"44,144"|"Patch, fill cracks, seal and restripe parking areas and access roads. 53,995 SF."|"1"|"CONCRETE,ASPHALT,OTHER"|"U"|"2005"|"10"|"58,600"|"Remove areas of concrete and reset pavers on concrete base at main entry east side. Replace asphalt walk with concrete walk at parent drop off."|"0"||||"0"||"1"|"U"|"2004"|"5"|"108,000"|"N"|"Patch and repair delaminated areas of running track and provide structural spray and line striping. Long jump is in need of sand traps."|"RECONCRETE"|"0"|"0"|"1"|"0"|"0"|"0"|"S"|"2000"|"57"|"4,000"|"At loading dock, clean and patch concrete spalling."|"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"35"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"S"|"2000"|"10"|"20,000"|"Provide closers on door that opens to corridor (40) units."|"1"|"S"|"2000"|"10"|"24,000"|"Modify handrails to ADA standards. Provide rounded handrails, 12 inch extension beyond to and bottom risers and continuous grip at three stairways."|"1"|"S"|"2000"|"35"|"0"||"1"|"1"|"S"|"2000"|"20"|"80,200"|"Replace Technology Panel PS3. Replace receptacles with GFI type. Replace transformers. Power connections to administration AC units."|"1"|"S"|"2000"|"10"|"50,000"|"Replace building mount exterior lighting. Replace crawlspace lighting."|"1"|"0"|"S"|"1980"|"0"|"209,000"|"Replace public address system including all wiring. Replace master clock system with new primex system."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"15"|"0"||"1"|"INSTRUCT"|"S"|"2000"|"20"|"0"||"1"|"COMMON"|"S"|"2000"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2000"|"37"|"0"||"MASONRY,STEEL"|"1"|"0"|"Paint on columns in main gym is bubbling"|"0"|"0"|"1"|"1"|"0"||"S"|"2000"|"25"|"26,000"|"Clean/repaint columns in C108. Clean/repaint various lintels. Route/recaulk crack in masonry wall and between precast panels. Rebuild portion of brick veneer. Caulk/seal/flash around mechanical room louvers."|"1"|"MASONRY"|"S"|"1951"|"15"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2000"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"12"|"70,000"|"Clean and replace deck as required below exterior wall above to mechanical in Team Locker Room. Entire HS roof survey needed some loose areas and seam failures."|"1"|"PLASTIC"|"S"|"2002"|"12"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"2000"|"15"|"68,000"|"Replace galvanized water service. Add backflow preventers and isolation valves."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"2000"|"15"|"5,500"|"Inspect buried drain lines. Repair roof vent."|"1"|"NAT_GAS"|"S"|"1990"|"5"|"30,000"|"Increase storage tank temperature. Add 140 degree hot water loop to kitchen."|"1"|"S"|"2000"|"15"|"22,000"|"Replace fixtures."|"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1978"|"5"|"0"||"1"|"S"|"1978"|"5"|"0"||"1"|"S"|"2000"|"5"|"60,000"|"Serve all areas of administration with DX systems."|"1"|"S"|"1996"|"7"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"2005"|"15"|"45,000"|"Add visual notification."|"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1996"|"1996"|"5,000"|"Add fire extinguishers and cabinets."|"1"|"S"|"2000"|"5"|"107,000"|"Replace exit lighting and circuitry. Replace emergency lighting and circuitry. Provide exterior emergency egress lighting."|"1"|"S"|"1996"|"10"|"325,000"|"Provide new NFPA Level 1 generator and distribution."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"1,840,727"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/30/2010 11:04:59 AM| 751|"Island Park UFSD"|"28023102"|"Francis X Hegarty Elementary School"|"0001"|"06/03/2010"|"Radcliff Road"|"Island Park"|" 11558"|"ANNUAL"|"04/01/2011"|"1929"|"40884"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"382"|"K,1,2,3,4"|"0"|"0"|"0"|"382"|"0"|"1"|"OTHER"|"Stage"|"36"|"28800"|"ART,AV,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,TEACHRSRC"||"1"|"1"|"6000"|"0"|"0"|"S"|"2002"|"18"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"16"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"11"|"0"||"1"|"S"|"2008"|"23"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"43"|"233000"|"Budget for increase of site electric and repair of select lights"|"1"|"S"|"2009"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"7"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1929"|"6"|"0"||"1"|"CONCRETE"|"S"|"2001"|"6"|"0"||"1"|"E"|"2005"|"21"|"226000"|"Budget for upgrades and maintenance and repairs"|"1"|"S"|"2005"|"21"|"0"|"N"||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"27"|"0"||"1"|"S"|"1956"|"20"|"700"|"Budget for repairs"|"1"|"S"|"2005"|"20"|"173285"|"Budget for repairs and replacements and upgrades "|"1"|"S"|"1956"|"1"|"200000"|"Budget for repairs and upgrades"|"1"|"S"|"1975"|"2"|"68000"|"Budget for upgrades "|"1"|"S"|"S"|"1956"|"2"|"0"||"1"|"S"|"1956"|"7"|"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"11"|"0"||"1"|"S"|"1956"|"2"|"0"||"1"|"1"|"S"|"2004"|"20"|"45000"|"Budget for replacements "|"0"||||"0"||"1"|"COMMON"|"S"|"2005"|"3"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"2"|"0"||"1"|"COMMON"|"S"|"1956"|"8"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"8"|"0"||"CONCRMETAL,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1956"|"7"|"0"||"MASONRY"|"1"|"0"|"Cracks south of east wing stairwell"|"0"|"0"|"0"|"0"|"0"||"S"|"1956"|"18"|"0"||"1"|"MASONRY"|"S"|"1929"|"5"|"0"||"1"|"MASONRY"|"S"|"1929"|"18"|"0"||"S"|"S"|"0"|"0"|"2003"|"11"|"0"||"1"|"S"|"1956"|"2"|"5500"|"Budget for repairs "|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"28"|"0"||"METONMET,WOODONWOOD,CONMETMET"|"BUILTUP"|"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"8"|"48500"|"Budget for replacement and repairs"|"0"|||||"0"||"1"|"IRON,COPPER"|"S"|"1956"|"7"|"0"||"1"|"IRON,COPPER"|"S"|"1956"|"7"|"0"||"1"|"NAT_GAS"|"E"|"2008"|"13"|"0"||"1"|"S"|"1956"|"1"|"353000"|"Budget for renovations of select lavatories and replacement fo fixtures"|"0"||"1"|"BOILERSTEA"||"E"|"2008"|"28"|"0"||"1"|"E"|"2008"|"27"|"0"||"1"|"S"|"2008"|"13"|"0"||"1"|"E"|"2008"|"23"|"0"||"1"|"S"|"2008"|"6"|"0"||"1"|"S"|"1956"|"7"|"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"1997"|"6"|"0"||"1"|"S"|"1997"|"6"|"0"||"1"|"S"|"1929"|"1929"|"0"||"1"|"S"|"1956"|"0"|"9500"|"Budget for replacements"|"0"||||"0"||"1"|"1"|"450000"|"Budget to for ADA access addition to elevator and select lavatories"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||"WARMING"||"1"||"FAIR"|"Currently using stage a non instructional area as a classroom $137500"|"1904985"|"S"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.cpm"|"Douglas H Adil RA"|"021836"|"I accept"|12/30/2010 11:13:39 AM| 752|"Fairport CSD"|"26130106"|"Bus Center"|"5010"|"08/19/2010"|"860 AYRAULT RD "|"FAIRPORT "|" 14450-8901"|"ANNUAL"|"08/01/2011"|"1959"|"11095"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus dispatch and maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"0"|"0"|"0"|"25000"|"S"|"2000"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1959"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1959"|"10"|"0"||"1"|"S"|"1959"|"10"|"0"||"1"|"UTIL"|"BELOW"|"U"|"1959"|"5"|"130000"||"1"|"S"|"2004"|"5"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1985"|"5"|"1300000"||"1"|"ASPHALT"|"S"|"1985"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1959"|"5"|"0"||"1"|"S"|"1970"|"20"|"0"||"1"|"S"|"1970"|"20"|"0"||"1"|"S"|"1985"|"5"|"0"||"1"|"U"|"1985"|"5"|"3000"|"Replace locker room lockers"|"1"|"S"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"U"|"1985"|"1"|"500000"|"Replace 3 bus lifts"|"1"|"0"|"U"|"1990"|"5"|"134550"|"Replace distribution system"|"1"|"S"|"2004"|"10"|"0"|"1 Replace T 12 fixtures 2 Add occupancy sensors"|"1"|"1"|"S"|"2010"|"10"|"0"|"Add wireless clocks"|"0"||||"0"||"1"|"COMMON"|"U"|"1970"|"5"|"4400"|"Replace office carpet"|"1"|"COMMON"|"U"|"1985"|"5"|"8600"|"Replace VCT"|"1"|"COMMON"|"U"|"1985"|"5"|"9700"|"Replace floor tile"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1959"|"20"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"U"|"1959"|"5"|"15473"|"Repoint brick veneer"|"1"|"MASONRY"|"S"|"1959"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1980"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1959"|"10"|"0"||"CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"1"|"0"||"1"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"1990"|"10"|"350000"||"0"|||||"0"||"1"|"COPPER"|"S"|"1959"|"15"|"0"|"Replace shut off valves"|"1"|"IRON,COPPER"|"S"|"1959"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"1990"|"5"|"0"|"Replace dated sink and water cooler and faucets"|"1"|"CV"|"1"|"BOILERSTEA,FURNACE"||"S"|"2000"|"25"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1990"|"10"|"0"|"Replace window AC systems with DX split systems"|"1"|"S"|"1990"|"2"|"0"|"1 Add ventilatin systems to wash area, repair shop and paint room 2 Add exhaust systems 3 Provide HVAC system for office suite"|"1"|"S"|"2000"|"15"|"0"|"1 Replace isolation vavles 2 Replace unit heater"|"1"|"S"|"1990"|"15"|"0"|"Clean ductwork systems"|"1"|"S"|"1990"|"5"|"0"|"Tie radiation, cabinet heaters and unit heaters into DDC"|"1"|"S"|"2000"|"5"|"0"|"Replace fir alarm system "|"1"|"S"|"2000"|"5"|"0"||"1"|"S"|"1990"|"1990"|"0"||"1"|"S"|"2003"|"12"|"0"|"1 Add discharge lighting 2 Convert battery emergency lights to generators"|"0"||||"209590"|"Add emergency generator"|"1"|"1"|||"FAIR"||"FAIR"||"1"|"1"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"1"||"FAIR"||"6743613"|"U"|"1"|"Clark Patterson Lee"|"205 St. Paul Street Suite 500 Rochester NY 14604"|"585-454-4570"|"tliebert@clarkpatterson.com"|"Todd M Liebert"|"021538"|"I ACCEPT"|12/30/2010 11:16:45 AM| 753|"Kenmore-Tonawanda UFSD"|"14260103"|"Hoover Midle School"|"0007"|"08/08/2010"|"249 THORNCLIFF RD "|"KENMORE "|" 14223"|"ANNUAL"|"07/01/2011"|"1956"|"201,957"|"3"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"659"|"6,7,8"|"0"|"1"|"1"|"659"|"0"|"0"|||"57"|"48,806"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"18,000"|"NF"|"1995"|"1"|"179,000"|"Remove underground tank, piping, accessories, estimated 500 cu.yds. of contaminated soil and 1,000 gallons of unused oil."|"1"|"MUN_UTILIT"|"S"|"2000"|"1"|"242,000"|"Relocate water meters, backflow preventers and fire hydrants away from building. New backflow preventer and exterior enclosure for athletic fields."|"1"|"MUN_UTILIT"|"S"|"1956"|"12"|"0"||"1"|"S"|"1956"|"1"|"69,000"|"Install emergency gas shutoff system in Science rooms and Home Economics rooms."|"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"1995"|"5"|"25,000"|"Replace existing catch basins, add 2 additional catch basins and regrade to existing catch basins."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"10"|"0"||"1"|"CONCRETE"|"S"|"1995"|"5"|"50,000"|"Replace deteriorated and broken concrete sidewalks."|"0"||||"0"||"1"|"S"|"1995"|"5"|"50,000"|"N"|"Regrade existing athletic fields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1956"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"1995"|"5"|"200,000"|"Replace ceilings in Corridors, Kitchen and Gymnasium."|"1"|"S"|"1995"|"15"|"0"||"1"|"S"|"S"|"1995"|"1"|"150,000"|"Replace hardware with lever locksets and closers, replace doors at stairhalls and enclose stairhalls."|"1"|"S"|"1967"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"0"|"294,000"|"Provide GFCI receptacles, emergency shutdowns and replace older vintage panel boards."|"1"|"S"|"2002"|"5"|"47,000"|"Replace various old interior and exterior fixtures."|"1"|"1"|"U"|"2003"|"0"|"410,000"|"Replace public address (PA) system, sound system in Auditorium, upgrade telephone system, lower telephone sets to meet A.D.A. requirements, install new assistive listening at Gymnasium."|"1"|"S"|"2000"|"1"|"69,000"|"Replace hot water heater and circulation pump."|"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"1995"|"5"|"70,000"|"Replace ceramic tile and quarry tile in Kitchen and Serving areas."|"1"|"INSTRUCT,COMMON"|"S"|"1967"|"5"|"125,000"|"Replace wood floors in Gymnasium and miscellaneous Classrooms."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1967"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"1"|"1"|"1"||"S"|"2008"|"2"|"100,000"|"Masonry restoration required, repoint and regrout masonry."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"3"|"75,000"|"Replace exterior doors and replace security system motion sensors."|"1"|"S"|"1995"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"Y"|"1983"|"5"|"340,000"|"Replace existing original windows in the 1967 Classroom wing."|"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"0"||"1"|"PLASTIC"|"S"|"2008"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1956"|"1"|"6,000"|"Install backflow preventer on boiler make-up water."|"1"|"IRON,GALVANIZED,COPPER,LEAD"|"S"|"1956"|"1"|"11,500"|"Replace existing grease traps."|"1"|"NAT_GAS"|"S"|"2000"|"5"|"138,000"|"Replace hot water heater, storage tank piping and accessories."|"1"|"S"|"2004"|"1"|"145,000"|"Renovate Locker Room, replace drinking fountains with A.D.A. electric water coolers, hose bibbs in gang lavatories."|"1"|"VAV"|"1"|"BOILERSTEA"||"S"|"2002"|"3"|"460,000"|"Replace boilers and accessories."|"1"|"S"|"2000"|"7"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"U"|"2002"|"0"|"1,610,000"|"Replace and add new unit ventilators, replace exhaust fans and relief hoods."|"1"|"S"|"1956"|"3"|"200,000"|"Replace boiler feed unit and miscellaneous piping."|"1"|"S"|"1956"|"5"|"70,000"|"Internally clean ductwork."|"1"|"S"|"2002"|"5"|"260,000"|"Update controls on new equipment."|"1"|"S"|"2003"|"0"|"60,000"|"Provide additional code required notification signals."|"1"|"S"|"2003"|"0"|"21,000"|"Provide additional code required smoke detection."|"1"|"S"|"1995"|"1995"|"287,500"|"Reconstruction work at Stage, install sprinkler system for Stage."|"1"|"S"|"2003"|"0"|"156,000"|"Provide additional exit signage, and interior and exterior emergency lighting."|"1"|"U"|"1956"|"0"|"178,000"|"Replace emergency generator and distribution system."|"1"|"0"|"50,000"|"Provide A.D.A. accessibility in Locker Rooms."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"7,300,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street Williamsville NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 11:23:20 AM| 756|"East Syracuse-Minoa CSD"|"42040106"|"District Office"|"1004"|"8/19/10"|"407 FREMONT RD "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/10"|"1966"|"8250"|"2"|"0"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"1"||||||"0"|"0"|"NONE,ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"15"|"0"||"1"|"S"|"1966"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2010"|"40"|"0"|"Site lighting updated w/ "Safe + Sound" project."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"MUNI"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"|"Resurfaced & expanded parking w/ "Safe + Sound" project."|"1"|"CONCRETE"|"E"|"2010"|"25"|"0"|"Sidewalks replaced w/ "Safe + Sound" project. "|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2010"|"50"|"0"|"Joints sealed between foundation/floor w/ EXCEL funds."|"1"|"S"|"2010"|"50"|"0"|"Patched & painted w/ EXCEL funds"|"1"|"S"|"2010"|"50"|"0"|"Patched & painted w/ EXCEL funds"|"1"|"E"|"2010"|"25"|"0"||"0"||||"0"||"1"|"E"|"E"|"2010"|"30"|"0"|"Door hardware replaced w/ EXCEL funds."|"1"|"S"|"2010"|"25"|"0"||"1"|"E"|"2010"|"40"|"0"|"Elevator installed w/ EXCEL funds."|"1"|"1"|"S"|"1966"|"10"|"105,000"|"Recommend replacing 800 MDP & branch panels"|"1"|"E"|"2010"|"30"|"0"|"Upgraded w/ Energy Performance Contract."|"1"|"1"|"E"|"2010"|"15"|"0"|"Additional outside lines added w/ "Safe + Sound" project."|"0"||||"0"||"1"|"COMMON"|"E"|"2010"|"15"|"0"|"Replaced w/ EXCEL funds. "|"1"|"COMMON"|"E"|"2010"|"15"|"0"|"Replaced w/ EXCEL funds. "|"1"|"COMMON"|"S"|"2010"|"20"|"0"|"Ceramic tile @ lobby"|"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1966"|"50"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"45"|"0"|"Brick re-pointing & sill replacement completed w/ EXCEL funds."|"1"|"MASONRY"|"S"|"1966"|"45"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2010"|"30"|"0"|"Door & hardware replaced w/ EXCEL funds."|"1"|"S"|"2010"|"25"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"NA"|"2010"|"30"|"0"|"Upper level windows replaced w/ EXCEL funds."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"20"|"0"|"Roof replaced w/ EXCEL funds."|"0"|||||"0"||"1"|"COPPER"|"S"|"1966"|"15"|"0"||"1"|"IRON"|"S"|"2009"|"50"|"0"|"PVC @ 2nd floor toilet rooms"|"1"|"ELECTRIC"|"E"|"2009"|"10"|"0"||"1"|"E"|"2010"|"30"|"0"|"(2) toilet rooms re-configured w/ EXCEL funds. "|"1"|"CV"|"1"|"BOILERWATE"||"E"|"2010"|"50"|"0"|"Replaced w/ Energy Performance Contract."|"1"|"S"|"1966"|"15"|"0"||"1"|"E"|"2010"|"35"|"0"|"Replaced w/ Energy Performance Contract/EXCEL funds."|"1"|"E"|"2010"|"35"|"0"|"Replaced w/ Energy Performance Contract"|"1"|"S"|"1966"|"15"|"0"||"1"|"S"|"1966"|"10"|"0"||"1"|"E"|"2010"|"25"|"0"|"Replaced w/ Energy Performance Contract"|"1"|"E"|"2010"|"15"|"0"|"Replaced w/ "Safe + Sound" project."|"1"|"E"|"2010"|"15"|"0"|"Replaced w/ "Safe + Sound" project."|"0"||||"0"||"1"|"E"|"2010"|"15"|"0"|"Existing LED exits & battery packs in corridors"|"0"||||"88,000"|"Recommend adding emergency generator."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"1"|"1"|"0"|"0"||||"1"||"GOOD"||"193,000"|"S"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 11:38:38 AM| 757|"Williamsville CSD"|"14020306"|"North High School"|"0010"|"08/02/2010"|"1595 HOPKINS ROAD "|"AMHERST "|" 14221"|"ANNUAL"|"07/01/2011"|"1968"|"234111"|"2"|"13"|"2"|"DISTRICT"|"INSTRUCT"||"1508"|"9,10,11,12"|"0"|"1"|"0"|"1508"|"0"|"0"|||"85"|"74375"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP,OTHER"|"career center fitness rm planetarium"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1968"|"5"|"0"||"1"|"S"|"1967"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"0"||"1"|"CONCRETE"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"18"|"0"||"1"|"S"|"2002"|"18"|"0"||"0"|"S"|"2002"|"17"|"0"||"1"|"S"|"S"|"2002"|"15"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"1"|"S"|"2008"|"20+"|"0"||"1"|"U"|"1968"|"2"|"39000"|"at library"|"1"|"1"|"S"|"2006"|"20+"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"18"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2005"|"16"|"0"||"1"|"COMMON"|"S"|"2002"|"19"|"0"||"1"|"COMMON"|"S"|"1968"|"13"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"reinforced concrete"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"20"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"1"|"1"|"0"||"S"|"2002"|"20"|"0"||"1"|"MASONRY"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"12"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2010"|"20+"|"0"|"Complete window replacement scheduled for 2011"|"METONMET,OTHER"|"SINGLEPLY,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"minor vegetation growth"|"S"|"2002"|"17"|"0"||"1"|"PLASTIC"|"S"|"2002"|"17"|"0"||"1"|"COPPER"|"S"|"1968"|"20"|"0"||"1"|"IRON"|"S"|"1968"|"20"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"2008"|"20+"|"0"||"1"|"E"|"2008"|"20+"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2003"|"20+"|"0"||"0"|"S"|"2003"|"20+"|"0"||"1"|"S"|"2000"|"2000"|"0"||"1"|"S"|"1985"|"15"|"0"||"1"|"E"|"2010"|"20+"|"0"|"scheduled for replacement in 2010 to 2011"|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"1"|"CLASSROOMS,HALLWAYS,OTHER"|"toilet rooms"|"0"|||"1"|"1"||"some ceiling tiles have water stains"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Building staff report that filters are changed approximately 3 times per year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"|"0"|"GOOD"||"39000"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/30/2010 11:39:48 AM| 758|"Riverhead CSD"|"58060204"|"Aquebogue Elementary School"|"0005"|"06/10/2010"|"499 Main Street"|"Aquebogue"|" 11931"|"ANNUAL"|"05/01/2011"|"1929"|"80100"|"1"|"4"|"1"|"DISTRICT"|"INSTRUCT"||"524"|"K,1,2,3,4"|"0"|"1"|"1"|"524"|"0"|"0"|||"31"|"21,940"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED"||"1"|"0"|"0"|"2"|"16,500"|"S"|"1952"|"0"|"12,840"|"Provide proper overfill signage, investigate & repair alarm conditions on both tanks."|"1"|"MUN_UTILIT"|"S"|"2001"|"31"|"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"31"|"38,520"|"Provide grease trap on kitchen line and provide additional capacity for system."|"1"|"S"|"2001"|"35"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"14"|"0"||"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"0"|"Provide 30 additional parking stalls, resurface N parking lot (12,000 sf), repair/reseal S parking lot (30,000 sf)."|"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"5"|"0"|"Replace 375 sf of cracked sidewalk & 80 sf of cracked sidewalk along Edgar Avenue and add curb cuts at Edgar Avenue."|"1"|"S"|"2001"|"5"|"0"|"Provide ADA compliant base to replace sand (12,500 sf)."|"1"|"S"|"2001"|"5"|"0"|"N"|"Provide field irrigation, provide 1,500 lf of 6' CL fencing at N & W property lines."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2010"|"15"|"0"|"Replace original building classroom doors this year."|"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"|"Lift to stage."|"1"|"1"|"S"|"2001"|"14"|"98,225"|"Provide additional circuit to faculty room, add GFI outside gym, provide computer power in old section of building, run new circuit for computer room A/C & provide lightning protection."|"1"|"S"|"2001"|"30"|"19,260"|"Redo 3 way switches in gym & cafeteria, repair/replace east basement stair fixture, provide exterior security lighting at NE corner & north side of building."|"1"|"1"|"S"|"2001"|"15"|"0"|"Provide additional CCTV cameras (6), replace telephone system, add int. phone at greeters desk."|"0"||||"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"1"|"COMMON"|"S"|"2001"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2001"|"15"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"15"|"0"||"1"|"MASONRY,METAL"|"S"|"2008"|"15"|"0"||"1"|"MASONRY"|"S"|"2008"|"15"|"0"||"S"|"S"|"0"|"1"|"2001"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2001"|"15"|"0"||"METONMET,WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"S"|"2001"|"5"|"0"|"Replace roofs on 1929 & 1950's wings."|"0"|||||"0"||"1"|"COPPER"|"S"|"2001"|"40"|"0"|"Add hose faucet at gym & replace older isolation valves."|"1"|"IRON"|"S"|"2001"|"40"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"0"|"16,050"|"Replace DHWH in old boiler room."|"1"|"S"|"2001"|"40"|"0"|"Continue sink/faucet replacement program, repair slop sink near psych. Office, replace 2 slops sinks, remove df bubblers from CR sinks & provide separate basis (5 locations)."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2001"|"40"|"450,684"|"Clean and tune DHW boiler, replace original building boilers."|"1"|"S"|"2001"|"40"|"0"||"1"|"S"|"2001"|"40"|"0"||"1"|"S"|"2001"|"10"|"616,320"|"Repair noisy gym & cafeteria H&V units, replace UVs in original building, repair music room exhaust, replace rooftop spinner, provide FAI for math lab, ESL room, reading room & psychologist, remove incinerator."|"1"|"S"|"2001"|"35"|"0"||"1"|"S"|"2001"|"30"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"6"|"0"|"Investigate and repair bather trouble alarm -warranty item."|"1"|"S"|"2001"|"6"|"0"||"0"||||"0"||"1"|"S"|"2001"|"11"|"1,284"|"Add emergency light fixture to library."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"0"|"0"|"GOOD"||"1,253,183"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"salvesen@bbsarch.com"|"Lawrence Salvesen, AIA"|"020623"|"I ACCEPT"|12/30/2010 11:40:51 AM| 759|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"Building #9 - Pole Barn - Building Trades"|"0062"|"05/11/2010"|"RD 2 "|"Painted Post"|"14870"|"ANNUAL"|"08/01/2011"|"2009"|"7200"|"1"|"2"|"1"|"DISTRICT"|"INSTRUCT"||"24"|"9,10,11,12"|"0"|"0"|"1"|"24"|"0"|"0"|||"1"|"7200"|"TECHSHOP"||"0"||||||||"0"||"1"|"WELL"|"S"|"2009"|"20"|"0"||"1"|"SITESEPT"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"CONCRETE"|"E"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2009"|"40"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"E"|"2009"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"20"|"0"||"1"|"E"|"2009"|"5"|"0"||"1"|"1"|"E"|"2009"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"E"|"2009"|"40"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"40"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"40"|"0"||"1"|"METAL"|"S"|"2009"|"15"|"0"||"0"|||||"0"||"E"|"E"|"1"|"1"|"2009"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,WOOD"|"E"|"NA"|"2009"|"20"|"0"||"WOODONWOOD"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2009"|"30"|"0"||"0"|"IRON,COPPER,PVC"|"S"|"2009"|"30"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"15"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"CV"|"1"|"BOILERWATE,OTHER"|"Radiant panels on exterior of the building."|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"GOOD"||"$75,000"|"E"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|12/30/2010 11:42:08 AM| 760|"Chappaqua CSD"|"66100406"|"Horace Greeley HS Gym Bldg A"|"0001"|"08/24/2010"|"70 Roaring Brook Road"|"Chappaqua"|" 10514"|"ANNUAL"|"08/01/2011"|"1971"|"37500"|"1"|"0"|"1"|"DISTRICT"|"INSTRUCT"||"1309"|"9,10,11,12"|"0"|"1"|"0"|"1309"|"0"|"0"|||"0"|"0"|"GYM"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1971"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1971"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"10"|"0"||"1"|"S"|"1971"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1996"|"4"|"3900"|"Replace curb"|"0"|"ASPHALT"|"S"|"1996"|"3"|"5000"|"Replace asphalt walk up to baseball field"|"0"||||"0"||"1"|"S"|"2003"|"6"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1971"|"6"|"0"||"1"|"S"|"1971"|"6"|"0"||"1"|"S"|"1971"|"6"|"0"||"1"|"S"|"1996"|"6"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"S"|"1996"|"6"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"3"|"48000"|"Big gym lighting should be replaced with energy efficient type Girls locker room needs complete lighting replacement No parts available for damaged lights"|"1"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1971"|"10"|"0"||"1"|"COMMON"|"S"|"1971"|"10"|"0"||"1"|"COMMON"|"S"|"1971"|"15"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1971"|"6"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1971"|"6"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"1971"|"6"|"0"||"S"|"S"|"0"|"1"|"1996"|"6"|"0"||"1"|"S"|"1971"|"6"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1996"|"6"|"0"||"METONMET,WOODONWOOD,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"1"||"U"|"1998"|"0"|"552530"|"Per roof consultant replace roof asap to avoid further damage"|"1"|"PLASTIC"|"S"|"1998"|"0"|"0"|"See roofing comment above"|"1"|"COPPER"|"S"|"1969"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1971"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"10"|"0"|"Two 300 gallon Indirect units in winter and 65 gallon gas fired in summer"|"1"|"S"|"1971"|"10"|"0"|"Repaired or replaced as necessary"|"0"||"1"|"BOILERSTEA"||"S"|"1965"|"5"|"0"||"1"|"S"|"1965"|"5"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"6"|"0"||"1"|"S"|"2002"|"3"|"0"|"Steam to water heat exchanger is beyond its expected useful life and leaking condensate pump in pit below mech room need replacement Both are scheduled as part of upcoming energy performance contract"|"0"||||"0"||"1"|"S"|"1971"|"6"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"1996"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Gym ceiling"|"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"609430"|"U"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/30/2010 11:49:33 AM| 761|"Riverhead CSD"|"58060204"|"GROUNDS ADMIN OFFICE "|"0006"|"08/16/2010"|"270 Pulaksi Street"|"RIVERHEAD "|" 11901"|"ANNUAL"|"05/01/2011"|"1970"|"1800"|"1"|"7"|"1"|"DISTRICT"|"OTHER"|"Buildings & Grounds/Technology Offices"|"0"|"5,6"|"0"|"0"|"0"|"0"|"0"|"0"|||"2"|"1600"|"OTHER"|"Buildings & Grounds/Technology"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1970"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"1970"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"||"1"|"COMMON"|"S"|"1998"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"10"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1998"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1998"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"|"Replace two stairs out rear of building."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1970"|"10"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1970"|"10"|"0"||"1"|"IRON"|"S"|"1970"|"10"|"0"||"1"|"ELECTRIC"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"||"1"|"FURNACE"||"S"|"1970"|"5"|"100,000"|"Provide FAI for all rooms."|"1"|"S"|"1970"|"5"|"0"||"1"|"S"|"1970"|"5"|"0"||"1"|"S"|"1970"|"5"|"0"||"0"||||"0"||"0"|"S"|||"0"||"1"|"S"|"1970"|"5"|"0"||"1"|"S"|"2009"|"19"|"0"||"1"|"S"|"2009"|"19"|"0"||"0"||||"0"||"1"|"S"|"1995"|"5"|"0"||"0"||||"0"||"0"|"1"|"000"|"Alternative facilities are used if required (Administration Office)"|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"0"|"0"|"FAIR"||"100,000"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"salvesen@bbsarch.com"|"Lawrence Salvesen, AIA"|"020623"|"I ACCEPT"|12/30/2010 12:07:31 PM| 762|"Kenmore-Tonawanda UFSD"|"14260103"|"Philip Sheridan Elementary"|"0001"|"09/22/2010"|"3200 ELMWOOD AVE "|"TONAWANDA "|" 14150"|"ANNUAL"|"07/01/2011"|"1949"|"91690"|"2"|"2"|"1"|"PART"|"OTHER"|"DAYCARE"|"196"|"Pre-K"|"0"|"0"|"0"|"196"|"0"|"0"|||"6"|"4200"|"ADMIN,CAFE,COMPROOM,REMEDIAL,TEACHRSRC"||"1"|"0"|"0"|"1"|"12,000"|"NF"|"1949"|"1"|"136,000"|"REMOVE EXISTING TANK, PIPING AND ACCESSORIES REMOVE EST. 500 CU.YDS. OF CONTAMINATED SOIL AND 1000 GALLONS OF UNUSED OIL."|"1"|"MUN_UTILIT"|"S"|"1949"|"1"|"69,000"|"BACKFLOW PREVENTER AND EXTERNAL ENCLOSURE FOR DOMESTIC WATER."|"0"|"MUN_UTILIT"|"S"|"1949"|"10"|"0"||"1"|"S"|"1975"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"0"|"S"|"1949"|"6"|"0"||"0"||||"0"||"1"|"S"|"1975"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1995"|"5"|"150,000"|"RECONSTRUCT DETERIORATED ASPHALT PAVING IN PARKING LOT."|"1"|"CONCRETE"|"S"|"1975"|"5"|"50,000"|"REPLACE DETERIORATING AND BROKEN CONCRETE SIDEWALKS AND CURBS."|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"3"|"25,000"|"N"|"REGRADE ATHLETIC FIELD - FIELD HOCKEY GAME FIELD."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1949"|"10"|"0"||"1"|"S"|"1949"|"10"|"0"||"1"|"S"|"1975"|"15"|"0"||"1"|"S"|"2004"|"5"|"110,000"|"REPLACE CEILINGS IN THE CORRIDORS, KITCHEN AND MISC. CLASSROOMS."|"1"|"S"|"1975"|"2"|"130,000"|"REPLACE LOCKERS IN THE BOYS AND GIRLS LOCKER ROOMS."|"1"|"S"|"S"|"2004"|"2"|"150,000"|"REPLACE MISC. INTERIOR DOORS"|"1"|"S"|"1949"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"0"|"216,400"|"PROVIDE GFCI RECEPTACLES, REPLACE OLDER VINTAGE PANEL BOARDS AND BUILDING WIRING."|"1"|"S"|"2002"|"5"|"200,000"|"REPLACE AUDITORIUM THEATRICAL LIGHTING AND DIMMING SYSTEM AND VARIOUS OLDER BUILDING LIGHT FIXTURES."|"1"|"1"|"S"|"2002"|"1"|"189,000"|"REPLACE CLOCK SYSTEM, AUDITORIUM SOUND SYSTEM AND ASSISTIVE LISTENING SYSTEM UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"1990"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1975"|"10"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1949"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"|"NONE"|"1"|"1"|"0"|"0"|"0"|"NONE"|"S"|"1975"|"5"|"100,000"|"MASONRY RESTORATION REQUIRED. REPLACE BRICK, REPOINT AND REGROUT."|"1"|"MASONRY"|"S"|"1975"|"3"|"125,000"|"REPLACE WITH NEW SS CAP, NEW LINER, REPOINT, REGROUT AND INSTALL NEW REINFORCING BANDS."|"0"|||||"0"||"S"|"S"|"0"|"0"|"1979"|"1"|"80,000"|"REPLACE MISC. EXTERIOR DOORS AND REPLACE SECURITY SYSTEM MOTION SENSORS."|"1"|"S"|"1975"|"5"|"25,000"|"INSTALL ADDITIONAL RAMP AT ENTRANCE FOR ADA ACCESSIBILITY."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1987"|"10"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2008"|"20"|"0"||"1"|"PLASTIC"|"S"|"2008"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1949"|"1"|"6,000"|"INSTALL BACKFLOW PREVENTER ON BOILER MAKE UP WATER."|"1"|"IRON"|"S"|"1949"|"5"|"200,000"|"REPLACE BASEMENT CLOOR DRAINS AND PIPING, UPGRADE KITCHEN PLUMBING, INCLUDING NEW GREASE TRAPS, REPLACE SUMP AND ASSOCIATED PIPING, REPLACE VALVES AT WATER SERVICE."|"1"|"NAT_GAS"|"S"|"2003"|"10"|"0"||"1"|"S"|"2005"|"1"|"132,000"|"RENOVATE LOCKER ROOMS AND SECOND FLOOR TOILET ROOMS TO MEET ADA REQUIREMENTS, INSTALL FAUCETS WITH VACUUM BREAKER ON SERVICE SINKS, REPLACE WALL HYDRANT WITH NON-FREEZE INTEGRAL VACUUM BREAKER TYPE."|"1"|"CV"|"1"|"BOILERSTEA"||"S"|"2003"|"3"|"575,000"|"REPLACE BOILERS AND ASSOCIATED PIPING."|"1"|"S"|"2003"|"6"|"0"||"1"|"S"|"1990"|"6"|"0"||"1"|"U"|"1949"|"0"|"1,120,000"|"REPLACE/ADD UNIT VENTS, RELIEF HOODS AND EXHAUST FANS."|"1"|"S"|"1990"|"5"|"115,000"|"REPLACE BOILER FEED UNIT, PUMP AND MISC. PIPING."|"1"|"S"|"2004"|"6"|"0"||"1"|"S"|"2002"|"5"|"250,000"|"UPDATE CONTROLS WITH NEW EQUIPMENT"|"1"|"S"|"2002"|"0"|"7,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION SIGNALS."|"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED SMOKE DETECTION."|"1"|"S"|"2004"|"2004"|"0"||"1"|"S"|"2002"|"1"|"50,000"|"PROVIDE ADDITIONAL EXIT SIGNAGE, AND VARIOUS BUILDING EMERGENCY LIGHTING."|"1"|"U"|"1960"|"0"|"160,000"|"REPLACE EMERGENCY GENERATOR AND DISTRIBUTION SYSTEM."|"1"|"0"|"85,000"|"PROVIDE ADA ACCESSIBILE TOILET ROOMS ON 2ND FLOOR AND ADA ACCESSIBILITY FOR BOYS AND GIRLS LOCKER ROOMS."|"FAIR"||"FAIR"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"INACTIVE"|"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"0"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"GOOD"||"4,600,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN ST, WILLIAMSVILLE, NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/30/2010 12:10:54 PM| 763|"Kenmore-Tonawanda UFSD"|"14260103"|"Thomas Edison Elementary School"|"0010"|"06/30/2010"|"236 GRAYTON RD "|"TONAWANDA "|" 14150"|"ANNUAL"|"07/01/2011"|"1954"|"88,240"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"460"|"K,1,2,3,4,5"|"0"|"1"|"1"|"460"|"0"|"0"|||"24"|"19,700"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"15,000"|"NF"|"1954"|"1"|"207,000"|"Remove underground tank, piping, accessories, est. 675 cu. yd of contaminated soil and 1000 gallons of unused oil."|"1"|"MUN_UTILIT"|"S"|"1954"|"3"|"60,000"|"Provide Backflow Preventer and External Enclosure to Athletic Field."|"1"|"MUN_UTILIT"|"S"|"1954"|"25"|"0"||"1"|"S"|"1956"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"1954"|"6"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"5"|"25,000"|"Replace misc. areas of asphalt pavement."|"1"|"CONCRETE"|"S"|"2004"|"5"|"20,000"|"Replace misc. concrete walks and curbs."|"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"1954"|"5"|"50,000"|"N"|"Regrade Athletic Fields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1961"|"15"|"0"||"1"|"S"|"1961"|"15"|"0"||"1"|"S"|"1961"|"15"|"0"||"1"|"S"|"2004"|"3"|"60,000"|"Replace ceilings in the 1961 classroom wing."|"1"|"S"|"1961"|"5"|"85,000"|"Replace all lockers in the Boys & Girls Locker Rooms."|"1"|"S"|"S"|"2004"|"2"|"60,000"|"Replace hardware with new lever locksets and new doors at all stairhalls."|"1"|"S"|"1961"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"1"|"244,000"|"Replace older vintage electrical panels, provide GFCI receptacles, replace old wiring."|"1"|"S"|"2005"|"5"|"200,000"|"Replace Auditorium House Lighting & theatrical dimming system. Replace misc. older light fixtures."|"1"|"1"|"S"|"2002"|"1"|"120,000"|"Replace clock system, upgrade telephone system, add assistive listening system on the Auditorium sound system."|"0"||||"0"||"1"|"INSTRUCT"|"S"|"1985"|"3"|"100,000"|"Replace carpet in Kindergarten classrooms, Library, etc."|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"1961"|"5"|"35,000"|"Replace ceramic tile & quarry tile in the Kitchen / Servery Area."|"1"|"INSTRUCT"|"S"|"2004"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1961"|"15"|"0"||"MASONRY"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1961"|"10"|"0"||"1"|"MASONRY"|"S"|"1985"|"5"|"50,000"|"Masonry Restoration Required. Replace with new SS cap, liner and repoint."|"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"1"|"65,000"|"Replace misc. exterior doors and replace security system motion sensors."|"1"|"S"|"1985"|"1"|"35,000"|"Install new ADA ramp at entrances."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1985"|"10"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"E"|"2010"|"25"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1954"|"1"|"6,000"|"Install Backflow Preventer on Boiler make-up water."|"1"|"IRON,GALVANIZED,COPPER,LEAD"|"S"|"1954"|"1"|"26,000"|"Upgrade Kitchen Plumbing."|"1"|"NAT_GAS"|"S"|"1985"|"5"|"87,000"|"Replace hot water heaters, piping and accessories."|"1"|"S"|"2003"|"1"|"130,000"|"Replace drinking fountains with ADA Electric Water Coolers, faucets with vacuum breakers for service sinks, replace original lavs, replace wall hydrants with non freeze integral vacuum breaker type."|"0"||"1"|"BOILERSTEA"||"S"|"1990"|"0"|"140,000"|"Replace one Boiler and misc. equipment."|"1"|"S"|"1990"|"6"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"2002"|"0"|"1,400,000"|"Replace / add unit vents, relief hoods, exhaust fans and air handling units."|"1"|"S"|"1954"|"3"|"160,000"|"Replace Boiler Feed Unit and misc. piping."|"1"|"S"|"1954"|"5"|"70,000"|"Internally clean ductwork."|"1"|"S"|"2002"|"5"|"370,000"|"Update Controls with new equipment."|"1"|"S"|"2004"|"0"|"4,000"|"Provide additional code required notification signals."|"1"|"S"|"2004"|"0"|"4,000"|"Provide additional code required smoke detection."|"1"|"S"|"2000"|"2000"|"270,000"|"Install wet chemical fire hood suppression system in the Kitchen and new sprinkler system on stage with reconstruction work."|"1"|"S"|"1954"|"0"|"50,000"|"Add exit signage, interior & exterior emergency lighting."|"1"|"U"|"1954"|"0"|"160,000"|"Replace Emergency Generator and Distribution System."|"1"|"0"|"35,000"|"Provide ADA accessibility in the locker rooms."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||||"1"||"FAIR"||"6,500,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 12:14:52 PM| 764|"Pavilion CSD"|"18120104"|"Industrial Arts Equipment Storage"|"0002"|"11/02/2010"|"7014 BIG TREE "|"PAVILION "|" 14525"|"ANNUAL"|"08/01/2011"|"1940"|"7,038"|"1"|"0"|"1"|"DISTRICT"|"INSTRUCT"||"75"|"7,8,9,10,11,12"|"3"|"0"|"0"|"75"|"0"|"0"|||"0"|"0"|"TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1978"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"1978"|"30"|"0"||"1"|"S"|"2000"|"30"|"0"||"1"|"OTHER"|"BELOW"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2000"|"15"|"0"||"1"|"CONCRETE"|"S"|"1978"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1978"|"35"|"0"||"1"|"S"|"1978"|"30"|"0"||"1"|"S"|"1978"|"30"|"0"||"1"|"S"|"1988"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1978"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"10"|"7,000"|"Replace T-12 fixtures; add occupancy sensors."|"1"|"1"|"S"|"2000"|"10"|"4,000"|"Add access controls."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1978"|"10"|"0"||"0"|||||"0"||"1"|"INSTRUCT"|"S"|"1978"|"10"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1978"|"30"|"0"||"MASONRY,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1978"|"35"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1995"|"5"|"0"||"CONMETMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2000"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1980"|"2"|"15,000"|"Replace water heater."|"1"|"S"|"2002"|"10"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"25"|"332,000"|"Replace rooftop unit; provide dust collection system; replace paint hood."|"0"||||"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"5"|"0"||"1"|"S"|"2000"|"10"|"2,000"|"Expand coverage."|"1"|"S"|"2000"|"10"|"2,000"|"Expand coverage."|"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"362,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/30/2010 12:15:09 PM| 765|"BOCES Cayuga-Onondaga"|"05900000"|"Center for Learning"|"8020"|"11/9/10"|"12 Allen Street"|"Auburn"|" 13021"|"ANNUAL"|"9/1/2011"|"1994"|"12320"|"1"|"0"|"1"|"LSD_DIST"|"INSTRUCT"||"55"|"6,7,8,9,10,11,12,OTHER"|"0"|"1"|"0"|"55"|"0"|"0"|||"10"|"7120"|"ADMIN,OTHER"|"Support Staff - 2, Breakroom"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"S"|"1994"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1994"|"10"|"0"||"1"|"CONCRETE"|"S"|"1994"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1994"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2009"|"9"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1994"|"10"|"0"||"1"|"COMMON"|"S"|"1994"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1994"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"10"|"0"||"1"|"METAL"|"S"|"1994"|"10"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"15"|"0"|"Two sets of doors were replaced in 2010"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"4"|"67000"|"Replacement windows are needed."|"OTHER"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1994"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1994"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1994"|"4"|"4500"|"Replace hot water heater"|"1"|"S"|"1994"|"4"|"7500"|"Replace eight toilets"|"1"|"CV"|"1"|"FURNACE"||"S"|"1994"|"4"|"160000"|"Replace heat/air condition generating systems. Refer also to number 77 below."|"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"4"|"0"|"Refer to number 75F and G "|"1"|"S"|"1994"|"10"|"0"|"Partial replacement along with HVAC system. Refer to number 75F and G"|"0"||||"0"||"1"|"S"|"1994"|"4"|"0"|"Replacement. Refer to number 75F and G"|"1"|"S"|"1994"|"4"|"0"|"Refer to number 75F and G"|"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"10"|"0"||"1"|"S"|"1994"|"1994"|"0"||"1"|"S"|"1994"|"5"|"15000"|"Upgrade emergency lighting"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"254000"|"S"|"1"|"Samuel J. Cichello, Architect"|"2714 Franklin St, Weedsport, NY 13166"|"315-689-7090"|"sjcarch@gmail.com"|"Samuel J. Cichello"|"007611"|"I ACCEPT"|12/30/2010 12:16:11 PM| 766|"Rochester City SD"|"26160001"|"Clara Barton School #2"|"0002"|"07/07/2010"|"190 REYNOLDS STREET "|"ROCHESTER "|" 14608"|"ANNUAL"|"06/01/2011"|"1960"|"86909"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"364"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"0"|"364"|"0"|"0"|||"35"|"30214"|"ADMIN,ART,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,RSRCEROOM,SCIENCELAB,POOL,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"20"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"5"|"0"|"Secondary feeders replaced to new MDP"|"1"|"S"|"1991"|"25"|"0"||"0"||||"0"||"1"|"S"|"1991"|"20"|"14495"|"Drainage improvements"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1959"|"5"|"0"|"Resurface asphalt parking lot and slope to drain"|"1"|"CONCRETE,ASPHALT"|"S"|"1991"|"5"|"21,197"|"Replace asphalt sidewalk with concrete"|"1"|"S"|"1997"|"5"|"0"|"Resilient playground surface/replace swingset"|"1"|"S"|"1991"|"7"|"0"|"N"|"Fence replacement at 4', 6', and 12' height"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"45"|"0"||"1"|"S"|"1960"|"45"|"0"||"1"|"S"|"2003"|"45"|"0"||"1"|"S"|"2003"|"5"|"300,000"|"Replace classroom ceilings"|"1"|"S"|"1960"|"45"|"0"||"1"|"S"|"S"|"1960"|"5"|"130,000"|"replace doors and hardware"|"1"|"S"|"1960"|"45"|"0"||"1"|"S"|"1994"|"15"|"0"|"Cab interior requires renovation"|"1"|"1"|"E"|"2009"|"30"|"0"|"Replaced main distribution panel"|"1"|"S"|"2000"|"10"|"0"||"1"|"1"|"S"|"2009"|"10"|"0"|"IP Phone system added for admin. phones"|"0"||||"0"||"1"|"COMMON"|"S"|"1993"|"0"|"0"|"Replace library carpet"|"1"|"INSTRUCT,COMMON"|"S"|"1993"|"5"|"910,000"|"abate/replace VAT with VCT"|"1"|"COMMON"|"S"|"1993"|"45"|"0"||"1"|"INSTRUCT"|"S"|"1993"|"45"|"0"||"CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"45"|"0"||"MASONRY"|"0"|"0"|"weathered mortar joints"|"0"|"0"|"1"|"0"|"0"||"S"|"1960"|"45"|"0"||"1"|"MASONRY"|"S"|"1960"|"45"|"4000"|"repair/replace damaged masonry, repoint joints and cracks"|"0"|||||"0"||"S"|"S"|"1"|"1"|"2003"|"15"|"0"||"1"|"S"|"1960"|"5"|"14300"|"Stair replacement and handrail at loading dock"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1960"|"5"|"900000"|"replace double hung windows and insulated wall panels"|"METONMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"1"|"0"||"1"|"PLASTIC"|"S"|"1996"|"1"|"0"||"1"|"COPPER"|"S"|"2008"|"40"|"0"|"added toilet room to cafeteria"|"1"|"IRON,COPPER"|"S"|"2008"|"40"|"0"|"added toilet room to cafeteria, added grease trap to kitchen"|"1"|"NAT_GAS"|"S"|"2005"|"15"|"0"||"1"|"S"|"2008"|"25"|"0"|"added toilet room to cafeteria"|"0"||"1"|"BOILERSTEA,OTHER"|"unit ventilation"|"S"|"2000"|"30"|"0"|"boiler replaced in 2000"|"1"|"S"|"2000"|"35"|"0"|"Gas piping and train replaced during boiler replacement in 2000"|"1"|"S"|"2000"|"15"|"0"|"split system: serves rm 128"|"1"|"S"|"2000"|"10"|"0"|"AHU - controls added in 2000 EF - Replaced/repaired in 2000"|"1"|"S"|"2000"|"30"|"0"|"piping modified in 2000 during boiler replacement"|"1"|"S"|"2000"|"15"|"0"|"cleaned ductwork in 2000"|"1"|"S"|"2000"|"15"|"0"|"andover day control installed"|"1"|"S"|"1990"|"5"|"0"|"complete system replacement with new point addressable system"|"1"|"S"|"1990"|"5"|"0"|"replace detectors with addressable type and add new for code compliance"|"0"|"S"|||"0"||"1"|"S"|"2000"|"15"|"0"|"Add flourescents on generator life-safety circuit in gymnasium"|"1"|"S"|"2003"|"25"|"0"|"Heating system and life safety on generator"|"1"|"1"|"19500"|"Provide HC entrance from parking lot"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"AHU's and UV's provide OA to building"|"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"2,559,027"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/30/2010 12:18:04 PM| 767|"Island Park UFSD"|"28023102"|"Public Library"|"6002"|"06/03/2010"|"Radcliff Road"|"Island Park"|"11558"|"ANNUAL"|"04/01/2011"|"1958"|"5325"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"BOE meetings and professional development"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"1000"|"0"|"0"|"S"|"1970"|"21"|"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"21"|"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"21"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1970"|"21"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"13"|"0"||"1"|"CONCRETE"|"S"|"2003"|"19"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"31"|"0"||"1"|"S"|"1970"|"31"|"0"||"1"|"S"|"1970"|"11"|"25000"|"Budget for ongiong upgrades"|"1"|"S"|"2002"|"8"|"0"||"0"||||"0"||"1"|"S"|"S"|"1970"|"11"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"21"|"0"||"1"|"S"|"2002"|"8"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"6"|"0"||"1"|"COMMON"|"S"|"1958"|"6"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"31"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"31"|"3500"|"Budget for repairs"|"1"|"METAL"|"S"|"1970"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2006"|"11"|"4000"|"Budget for ongoing replacements"|"1"|"S"|"2003"|"9"|"0"||"0"|||||"0"||"1"|"ALUMINUM,WOODCLAD"|"U"|"Y"|"1970"|"0"|"196500"|"Budget for ongoing replacement and repairs"|"WOODONWOOD,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"U"|"1997"|"1"|"108000"|"Budget for repairs and replacement"|"0"|||||"0"||"1"|"COPPER"|"S"|"1970"|"11"|"0"||"1"|"IRON,COPPER"|"S"|"1970"|"21"|"0"||"1"|"OIL"|"S"|"2002"|"8"|"0"||"1"|"S"|"1970"|"23"|"93000"|"Budget for upgrades of lavatories "|"1"|"DD_MZ"|"1"|"BOILERWATE"||"U"|"2002"|"0"|"20000"|"Budget for replacement"|"1"|"S"|"1970"|"21"|"0"||"1"|"S"|"1970"|"1"|"25000"|"Budget for replacement "|"0"||||"0"||"0"||||"0"||"1"|"S"|"1970"|"11"|"0"||"1"|"S"|"1970"|"11"|"0"||"1"|"U"|"1970"|"1"|"5175"|"Budget for new control panels and pull stations "|"1"|"U"|"1970"|"1"|"4450"|"Budget for replacements"|"0"||||"0"||"1"|"S"|"2000"|"2"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"485165"|"U"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"63128660446"|"info@thefmgrp.com"|"Douglas H Adil RA"|"021836"|"I accept"|12/30/2010 12:22:31 PM| 768|"Duanesburg CSD"|"53010104"|"High School Relocatable"|"0004"|"08/20/2010"|"133 School Drive "|"DELANSON "|" 12053"|"ANNUAL"|"06/01/2011"|"1965"|"1000"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Art instruction"|"0"|"6,7,8,10,11,12"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ART"||"0"||||||||"0"||"1"|"OTHER"|"U"|"1965"|"0"|"0"||"1"|"OTHER"|"NF"|"1965"|"0"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"U"|"1965"|"0"|"0"||"0"||||"0"||"1"|"U"|"1965"|"0"|"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"ASPHALT,OTHER"|"U"|"1990"|"0"|"0"|"Wood ramp to front door is makeshift."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"1"|"1"|"0"|"0"|"U"|"2000"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"1"|"S"|"1965"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"1"|"S"|"1965"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"1"|"S"|"1965"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"||||"0"||"1"|"U"|"U"|"1990"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2000"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"1"|"S"|"2000"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"1"|"1"|"S"|"2000"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT"|"E"|"2009"|"15"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"1"|"0"||"0"|"1"|"0"|"U"|"1965"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"WOOD"|"0"|"1"||"0"|"1"|"0"|"1"|"1"|"Warped siding."|"U"|"1965"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"|||||"0"||"0"|||||"0"||"U"|"U"|"0"|"0"|"2005"|"0"|"0"|"Front door is not of adequate durability."|"1"|"U"|"1990"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"|||||"0"||"1"|"WOOD"|"U"|"Y"|"1965"|"0"|"0"|"Temporary type structure well past its useful life should be demolished."|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"1"|"0"|"1"|"1"|"0"|"1"|"0"|"Roof age."|"U"|"2000"|"10"|"0"|"Temporary type structure well past its useful life should be demolished."|"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"1"|"OTHER"|"Electric baseboard"|"U"|"1965"|"0"|"0"|"Inefficient electric baseboard."|"1"|"U"|"1965"|"0"|"0"|"Inefficient electric baseboard."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1990"|"0"|"0"|"Limited battery pack lighting."|"0"||||"0"||"1"|"1"|"50,000"|"Building has no restrooms."|"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"POOR"|"0"|"FAIR"|"Building is vented by windows only."|"1"|"0"|"1"|"0"|"0"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"||||"0"|"0"|"FAIR"|"Lacks storage."|"41,000"|"U"|"1"|"Synthesis Architects, LLP"|"162 Jay Street, Schenectady, New York 12305"|"518-370-1576"|"rdefranco@synthesisllp.com"|"John Senisi"|"020640"|"I ACCEPT"|12/30/2010 12:28:54 PM| 770|"Chappaqua CSD"|"66100406"|"Horace Greeley High School Complex"|"0015"|"08/24/2010"|"70 Roaring Brook Road"|"Chappaqua"|" 10514"|"ANNUAL"|"08/01/2011"|"1957"|"117600"|"2"|"16"|"0"|"DISTRICT"|"INSTRUCT"||"1309"|"9,10,11,12"|"0"|"1"|"0"|"1309"|"0"|"0"|||"50"|"37960"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,HLTHSUITE,KITCHEN,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"25000"|"S"|"2002"|"15"|"0"|"Fiberglass double wall tank installed in 2002"|"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"30000"|"Provide backflow preventer on domestic water service"|"1"|"MUN_UTILIT"|"S"|"1969"|"10"|"0"||"1"|"S"|"1957"|"5"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"10"|"0"|"Consider replacement of service during next major renovation or addition"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"OTHER"|"daylight"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"3"|"460000"|"Lot behind Bldg K needs to be resurfaced Entry parking lot by field needs resurfacing and new curbs"|"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"3"|"44400"|"Replace sidewalk areas on gym side of Bldg B and section of walk near Bldg F and upper level of walk between J and F and spalled ramp near east office exit"|"0"||||"0"||"1"|"S"|"2010"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"7"|"0"||"1"|"S"|"2004"|"7"|"0"||"1"|"S"|"2004"|"7"|"520000"|"Complete reconditioning of wood sills and casework throughout Bldgs C and D Allowance to upgrade wireglass with safety glass throughout"|"1"|"S"|"2004"|"2"|"56530"|"Repair ceilings in room K207 and K208 New suspended ceiling and lighting in lower level of L corridor Replace stained ceiling tiles in various areas in J and K wing classrooms"|"1"|"S"|"2003"|"7"|"0"||"1"|"S"|"S"|"2004"|"3"|"52200"|"Upgrade door hardware in art wing Add closer and emag hold open at smoke doors outside lecture K110 Add closers to door in L J and K wing classrooms Allowance to upgrade door louvers"|"1"|"S"|"2003"|"7"|"0"||"1"|"S"|"2004"|"7"|"0"||"1"|"1"|"S"|"1996"|"10"|"0"|"Replacement of original distribution system should be considered during next major renovation or addition"|"1"|"S"|"1996"|"5"|"0"|"Replacement or upgrade of light fixtures in E F G H and L are scheduled during upcoming energy performance contract"|"1"|"1"|"S"|"2004"|"15"|"0"|"Missing clocks in K208B L106 and L206 are scheduled to be replaced during upcoming energy performance contract"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2004"|"2"|"6360"|"Replace carpet on ramps C3 and C5"|"1"|"INSTRUCT,COMMON"|"S"|"2004"|"1"|"37000"|"Allowance for repairs including F corridor ramp near Art"|"1"|"COMMON"|"S"|"2004"|"10"|"0"||"1"|"COMMON"|"S"|"1957"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"7"|"0"||"MASONRY,STEEL"|"0"|"0"||"1"|"1"|"0"|"0"|"1"||"S"|"2003"|"3"|"39500"|"Allowance for brick and expansion joint repair in selected areas Select fascia and lintel repair as well as select flashing repair"|"1"|"MASONRY"|"S"|"2008"|"7"|"0"||"1"|"MASONRY"|"S"|"2003"|"7"|"0"||"S"|"S"|"0"|"1"|"2003"|"6"|"0"||"1"|"S"|"2003"|"2"|"14000"|"Repair handrail at stairs under bridge Replace sunken landing at stair near Bldg F in courtyard"|"1"|"U"|"0"|"1957"|"0"|"4000"|"Must add ladder to exit balcony without any ladder"|"1"|"ALUMINUM,STEEL"|"U"|"Y"|"2003"|"2"|"99000"|"Replace balance of original windows in L bldg Replace failed unit at stair K1 Windows in wings B C E F G H are scheduled for replacement during upcoming energy performance contract"|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"1"||"U"|"2003"|"0"|"1355770"|"Allow for insulation thermal scan and fall protection for OSHA at skylights and maint at cafeterias 6 and B and bldg B at L side Immediate replacement of roof at walkway 17 and EF connector Replacement of roof in 2or3 yrs at shop library and L bldg"|"1"|"PLASTIC"|"S"|"2003"|"0"|"0"|"included in roofing cost"|"1"|"COPPER"|"S"|"1969"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1969"|"10"|"0"|"Drainage issues in mech rms in bldgs D and E addressed in upcoming energy performance contract"|"1"|"NAT_GAS,ELECTRIC,OTHER"|"S"|"1996"|"10"|"0"|"Two 300 gallon indirect heaters when boilers are running Gas fired water heater Electric water heater in Bldg L"|"1"|"S"|"2010"|"20"|"0"|"New automatic fixtures being installed Fixtures are replaced as needed by building custodians"|"0"||"1"|"BOILERSTEA"||"S"|"2008"|"3"|"300000"|"Last old boiler should be replaced"|"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"1997"|"7"|"0"|"No central cooling system Several split systems adn rooftop units with cooling in various areas"|"1"|"U"|"2009"|"0"|"135000"|"Replace fans in mech rms in bldgs B C D which are past useful life expectancy Fans in bldgs E and F being replaced as part of upcoming energy performance contract"|"1"|"U"|"2002"|"0"|"0"|"Steam pipes fittings adn pumps are leaking Mech rms are flooding in bldgs C D F B and gym All are part of upcoming energy performance contract"|"1"|"S"|"1957"|"10"|"0"||"1"|"U"|"1957"|"0"|"0"|"Andover DDC in bldgs J K L Pneumatic controls elsewhere and past useful life expectancy It is scheduled for replacement with DDC control system as part of upcoming energy performance contract"|"1"|"S"|"1996"|"10"|"150000"|"Install visual alarm devices in classrooms within next year as required by current NYS code Bldgs E F G L do not have strobes and pull stations are not ADA compliant and should be upgraded during next major renovation or addition"|"1"|"S"|"1996"|"10"|"75000"|"Bldgs E F G L do not have smoke detectors in corridors Consider upgrading entire system during next major renovation or addition"|"1"|"S"|"1957"|"1957"|"0"|"Ansul system in kitchen and fire extinguishers throughout bldg No sprinklers in bldg"|"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"1"|"0"|"0"|"FAIR"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"3447390"|"U"|"0"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"cblack@kgdarchitects.com"|"Calvin L Black PE"|"078642"|"I ACCEPT"|12/30/2010 12:49:38 PM| 771|"Island Park UFSD"|"28023102"|"New Public Library"|"6004"|"11/05/2010"|"176 Long Beach Road"|"Island Park"|"11558"|"ANNUAL"|"04/01/2010"|"2002"|"13762"|"2"|"0"|"0"|"DISTRICT"|"DIST_ADMIN,OTHER,OTHER_ORG"|"Public Library"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"53"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"53"|"0"||"1"|"S"|"2002"|"53"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2002"|"53"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"23"|"0"||"0"|"CONCRETE"|"S"|"2002"|"23"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"68"|"0"||"1"|"S"|"2002"|"53"|"0"||"1"|"S"|"2002"|"53"|"0"||"1"|"S"|"2002"|"33"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"43"|"0"||"1"|"S"|"2002"|"68"|"0"||"1"|"S"|"2002"|"33"|"0"||"1"|"1"|"S"|"2002"|"43"|"0"||"1"|"S"|"2002"|"23"|"0"||"1"|"1"|"S"|"2002"|"13"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"68"|"1500 "|"Budget for repairs"|"CONCRETE,MASONRY,STEEL,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"68"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"2002"|"68"|"0"||"S"|"S"|"0"|"0"|"2002"|"33"|"0"||"1"|"S"|"2002"|"43"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"43"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"8"|"500"|"Budget for repairs"|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"33"|"0"||"1"|"IRON,COPPER"|"S"|"2002"|"43"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"13"|"0"||"1"|"S"|"2002"|"23"|"0"||"1"|"DD_MZ"|"1"|"BOILERWATE"||"S"|"2002"|"13"|"0"||"1"|"S"|"2002"|"43"|"0"||"1"|"S"|"2002"|"33"|"0"||"1"|"S"|"2002"|"33"|"0"||"1"|"S"|"2002"|"33"|"35"|"Budget for missing end cover"|"1"|"S"|"2002"|"18"|"250"|"Budget for repairs"|"1"|"S"|"2002"|"18"|"0"||"1"|"S"|"2002"|"13"|"0"||"1"|"S"|"2002"|"13"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"13"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Boiler Room"|"0"|||"0"|"0"|"250"|"Budget for mold removal"|"0"|"0"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"GOOD"||"1"||"1"|"1"|"0"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"4035"|"S"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Douglas H Adil RA"|"021836"|"I accept"|12/30/2010 12:51:07 PM| 772|"Franklin CSD"|"12070104"|"Bus Garage"|"5003"|"09/14/2010"|"26 INSTITUTE ST "|"FRANKLIN "|" 13775"|"ANNUAL"|"10/31/2011"|"1960"|"5997"|"1"|"2"|"0"|"DISTRICT"|"OTHER"|"bus garage"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"2"|"1500"|"0"|"0"|"S"|"1997"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"20"|"0"||"1"|"SITESEPT"|"S"|"1960"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1961"|"0"|"54000"|"high leg service: recommend replacing."|"1"|"S"|"1960"|"15"|"0"||"0"||||"0"||"1"|"S"|"2000"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"15"|"0"||"1"|"S"|"1960"|"20"|"0"||"1"|"S"|"1960"|"20"|"0"||"1"|"S"|"1960"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1960"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"|"bus lifts."|"1"|"1"|"S"|"1960"|"0"|"120000"|"end of useful life: replace with new."|"1"|"S"|"1998"|"10"|"85000"|"recommend replacing h1t2 system with t5 system."|"1"|"0"|"E"|"2010"|"20"|"0"|"system currently being installed."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1960"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"15"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1960"|"15"|"0"||"1"|"CONCRETE"|"S"|"1960"|"15"|"0"||"1"|"CONCRETE,METAL"|"S"|"1960"|"15"|"0"||"S"|"S"|"0"|"1"|"1960"|"1"|"50000"|"ovhd to be replaced (5)."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1999"|"20"|"0"||"CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1960"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1961"|"15"|"18000"|"re-direct water lines for cleaning buses"|"1"|"IRON"|"S"|"1961"|"15"|"0"||"1"|"ELECTRIC"|"S"|"1994"|"10"|"0"||"1"|"S"|"1961"|"2"|"15000"|"upgrade bathroom."|"0"||"0"|"BOILERWATE"||"S"|"1995"|"10"|"0"||"1"|"S"|"1995"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1995"|"2"|"20000"|"replace unit heater."|"0"||||"0"||"0"||||"0"||"0"||||"10000"|"no existing system. provide new."|"0"||||"12000"|"no existing system. provide new."|"0"||||"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"35000"|"provide emergency generator."|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_ FULL,OTHER"|"FAIR"|"h1t2 lighting."|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"0"|"POOR"||"0"|"0"|"0"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"489000"|"S"|"1"|"Clark Patterson Lee"|"59 Court Street Binghamton, N.Y. 13901"|"1-800-274-9000"|"rwarholic@clarkpatterson.com"|"John J. Martin, PE"|"057961"|"I ACCEPT"|12/30/2010 1:06:56 PM| 773|"Fairport CSD"|"26130106"|"Streppa Administration Building"|"1005"|"08/19/2010"|"38 W CHURCH ST "|"FAIRPORT "|" 14450-2130"|"ANNUAL"|"08/01/2011"|"1970"|"5870"|"2"|"0"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1970"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1970"|"10"|"0"||"1"|"CONCRETE"|"S"|"1970"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"1"|"S"|"1970"|"25"|"0"||"1"|"S"|"1970"|"25"|"0"||"1"|"S"|"1970"|"5"|"0"||"0"||||"0"||"1"|"S"|"S"|"1970"|"20"|"0"||"1"|"S"|"1970"|"20"|"0"||"0"||||"0"||"1"|"1"|"U"|"1970"|"5"|"34477"|"Replace MDP; add receptacles to office area; replace toilet room receptacles with GFI"|"1"|"S"|"2002"|"10"|"0"|"Add occupancy sensors; replace inc. fixtures; replace T12 fixtures."|"1"|"1"|"E"|"2010"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"1970"|"1"|"21660"|"Replace"|"1"|"COMMON"|"U"|"1970"|"5"|"8000"|"Abate VAT"|"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1970"|"20"|"0"||"WOOD,OTHER"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1970"|"20"|"0"||"1"|"METAL"|"S"|"1970"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1970"|"10"|"0"||"0"||||"0"||"1"|"S"|"1"|"1970"|"20"|"0"||"1"|"ALUMINUM"|"U"|"NA"|"1970"|"5"|"52475"|"Replace single pane windows"|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1990"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1970"|"15"|"0"||"1"|"IRON,COPPER"|"S"|"1970"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2006"|"10"|"0"|"Add DDC to recirc pump. Flue is not pitched properly. Add instantaneous elec water heater at each sink."|"1"|"S"|"1970"|"10"|"0"|"Replace 2 dated flush valves "|"1"|"CV"|"1"|"BOILERWATE"||"S"|"1970"|"5"|"0"|"Replace boiler plant"|"1"|"S"|"1970"|"15"|"0"|"Modify as part of boiler replacement"|"1"|"S"|"1970"|"5"|"0"|"Replace air cooled condensing unit"|"1"|"S"|"1970"|"5"|"0"|"Replace building air handling system $59,175. Replace toilet exhaust fans $5,000."|"1"|"S"|"1970"|"5"|"0"|"Replace original heating units and remove electric heaters $46,300. Replace heating pumps $15,000."|"1"|"S"|"1970"|"15"|"0"|"Clean ductwork systems and insulate."|"1"|"S"|"1970"|"2"|"0"|"Upgrade as part of equipment replacement."|"1"|"U"|"1970"|"1"|"16404"|"Replace fire alarm system"|"1"|"U"|"1970"|"1"|"13000"||"0"||||"0"||"1"|"S"|"2004"|"15"|"0"|"Add discharge lighting"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"829780"|"U"|"1"|"Clark Patterson Lee"|"205 St. Paul Street, Suite 500, Rochester, NY 14604"|"585-454-4570"|"tliebert@clarkpatterson.com"|"Todd M. Liebert"|"021538"|"I ACCEPT"|12/30/2010 1:10:14 PM| 776|"Riverhead CSD"|"58060204"|"District Bus Garage"|"5011"|"08/20/2010"|"702 Osborne Avenue"|"Riverhead"|" 11901"|"ANNUAL"|"05/01/2011"|"1937"|"31700"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus Garage"|"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"3"|"950"|"1"|"8,000"|"S"|"1990"|"30"|"90,000"|"Remove abandoned 275 gallon steel tanks, provide 200 gallon transmission fluid storage tank & provide 5,000 gallon propane storage tank. Replace dispensing monitoring system and provide fire suppression."|"1"|"MUN_UTILIT"|"S"|"1937"|"5"|"19,250"|"Provide RPZ if none exists."|"1"|"MUN_UTILIT"|"S"|"1937"|"5"|"96,500"|"Provide Code Compliant bus wash pad."|"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1960"|"5"|"0"||"1"|"S"|"1937"|"5"|"25,750"|"Restore leader/pool on North side, repitch/seal foundation & provide drainage at N. side of office area."|"0"||||"0"||"1"|"S"|"1960"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"1960"|"5"|"396,500"|"Repair rolling gate, provide 2nd rolling gate, repave rear part of bus parking lot (19,250 sf), pave south bus parking area (21,750 sf), pave south car parking lot (22,000 sf), replace concrete apron (1,500 sf) & repave west parking lot (9,900 sf)."|"1"|"CONCRETE"|"S"|"1960"|"5"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1937"|"15"|"0"||"1"|"S"|"1937"|"10"|"0"||"1"|"S"|"1937"|"10"|"0"||"1"|"S"|"1937"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1937"|"10"|"4,000"|"Replace door between repair and driver's area."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1960"|"5"|"1,750"|"Run new circuit for A/C unit."|"1"|"S"|"1960"|"5"|"24,000"|"Provide explosion proof lighting in 2nd pit, replace incandescent spots w/HID (6), provide additional lighting in vehicle storage area, add more lighting in south bay. Repair parking lot light fixture, provide additional lighting in parts storage."|"1"|"1"|"S"|"2005"|"15"|"26,000"|"Provide security camera system facing parking lot."|"0"||||"0"||"0"|||||"0"||"0"|"COMMON"|"S"|"2010"|"10"|"0"|"Replace floor tile in dispatching and driver's room."|"1"|"COMMON"|"S"|"1960"|"10"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1937"|"15"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1937"|"15"|"0"|"Repair cracking in stucco and resurface the building."|"1"|"MASONRY"|"S"|"1937"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1960"|"10"|"0"|"Replace three exterior doors that are rusted out."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"1960"|"10"|"79,608"|"Replace windows at storage garage area."|"METONMET"|"SINGLEPLY,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"1"||"S"|"1998"|"2"|"1,881,060"|"Remove and replace entire roof."|"0"|||||"0"||"1"|"GALVANIZED"|"S"|"1937"|"5"|"8,750"|"Provide air dryer & oil filter on air compressor and test compressor, replace main water shutoff valve, re-run hose faucet line at full size."|"1"|"IRON,GALVANIZED"|"S"|"1937"|"5"|"0"||"1"|"ELECTRIC"|"S"|"2000"|"5"|"0"||"1"|"S"|"1960"|"5"|"5,000"|"Provide eyewash station, repair or replace men's room urinal."|"1"|"CV"|"1"|"FURNACE"||"S"|"1995"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1995"|"5"|"122,500"|"Provide FAI for all office areas, provide explosion proof ventilation for 2nd pit, relocate vent for battery storage area, replace 3 spinners, repair/replace vehicle storage area exhaust fans (4), add electric UH to B&G area."|"0"||||"0"||"1"|"S"|"1960"|"5"|"0"||"1"|"S"|"1995"|"5"|"0"||"1"|"S"|"1990"|"5"|"39,000"|"Provide heat detection in vehicle storage area. Replace older type FA system."|"1"|"S"|"1990"|"5"|"0"||"0"||||"0"||"1"|"S"|"1960"|"5"|"7,000"|"Provide additional exit/emergency lighting."|"0"||||"39,000"|"Provide small emergency generator tied to dispatcher/office areas."|"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"|||"0"|"0"|"0"|"FAIR"||"2,865,668"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"salvesen@bbsarch.com"|"Lawrence Salvesen, AIA"|"020623"|"I ACCEPT"|12/30/2010 1:23:53 PM| 777|"Williamsville CSD"|"14020306"|"Forest Elementary"|"0006"|"08/22/2010"|"250 N. FOREST "|"WILLIAMSVILLE "|" 14221"|"ANNUAL"|"07/01/2011"|"1955"|"78200"|"1"|"3"|"4"|"DISTRICT"|"INSTRUCT"||"577"|"K,1,2,3,4"|"0"|"1"|"0"|"577"|"0"|"0"|||"40"|"33600"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2009"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"20"|"0"||"1"|"S"|"1986"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2010"|"20+"|"0"||"1"|"E"|"1986"|"10"|"0"||"0"||||"0"||"1"|"S"|"1986"|"10"|"0"||"0"||||"0"||"0"|"MUNI"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2004"|"10"|"0"||"1"|"CONCRETE"|"E"|"2004"|"10"|"0"||"1"|"E"|"2004"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"S"|"2001"|"20"|"0"||"1"|"S"|"1955"|"20"|"0"|"access and egress to boiler room"|"0"||||"0"||"1"|"1"|"S"|"2010"|"20+"|"0"||"1"|"S"|"2009"|"5"|"0"||"1"|"1"|"S"|"2009"|"19"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"14"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1992"|"13"|"0"||"1"|"COMMON"|"S"|"2001"|"19"|"0"||"1"|"COMMON"|"S"|"1955"|"18"|"0"||"SLABGRADE,OTHER"|"2 way concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"1992"|"20"|"0"||"1"|"MASONRY"|"S"|"1955"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1992"|"16"|"0"||"1"|"E"|"2004"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"0"|"Standing water under IRMA panels at cafeteria roof"|"S"|"1992"|"6"|"0"||"1"|"PLASTIC"|"S"|"1992"|"6"|"0"||"1"|"COPPER"|"S"|"2009"|"20"|"0"||"1"|"IRON"|"S"|"2009"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"||"1"|"BOILERSTEA"|"Unit ventilation"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement 2010 to 2012"|"1"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement 2010 to 2012"|"0"||||"0"||"1"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement in 2010 to 2011"|"1"|"S"|"1955"|"10"|"0"||"1"|"S"|"1955"|"10"|"0"||"1"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement in 2010 to 2012"|"1"|"S"|"2007"|"20+"|"0"||"1"|"S"|"2007"|"20+"|"0"||"1"|"S"|"1985"|"1985"|"0"||"1"|"S"|"1985"|"5"|"0"||"1"|"S"|"2007"|"20+"|"0"||"1"|"1"|||"GOOD"||"FAIR"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,OTHER"|"toilet rooms"|"0"|||"1"|"1"||"Some ceiling tiles have water stains"|"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"GOOD"|"0"|"FAIR"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"0"|"1"|"FAIR"||"0"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/30/2010 1:30:08 PM| 778|"Rochester City SD"|"26160001"|"Nathanial Rochester School #3"|"0003"|"07/07/2010"|"85 ADAMS STREET "|"ROCHESTER "|" 14608"|"ANNUAL"|"06/01/2011"|"1975"|"90416"|"3"|"3"|"1"|"DISTRICT"|"INSTRUCT"||"621"|"K,1,2,3,4,5,6,7,8"|"0"|"1"|"0"|"621"|"0"|"0"|||"45"|"37228"|"ADMIN,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,RSRCEROOM,TEACHRSRC"||"1"|"0"|"0"|"1"|"15000"|"S"|"1975"|"0"|"0"|"not used - abandoned"|"1"|"MUN_UTILIT"|"S"|"1998"|"30"|"0"|"water service owned by public utility"|"1"|"MUN_UTILIT"|"S"|"1975"|"25"|"0"|"sanitary sewer owned by public utility"|"1"|"S"|"2009"|"50"|"0"|"gas meter replaced"|"1"|"UTIL"|"BELOW"|"S"|"1975"|"15"|"0"||"1"|"S"|"1975"|"5"|"0"|"drainage improvements along east side of fields and in dumpster area"|"0"||||"0"||"1"|"S"|"1975"|"5"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1975"|"3"|"234000"|"full depth reconstruction of parking lot"|"1"|"CONCRETE,ASPHALT"|"S"|"2009"|"4"|"0"|"asphalt sidewalk replacement near fields and concrete repair at various locations around school site."|"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"1975"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1975"|"50"|"0"||"1"|"S"|"2000"|"5"|"0"|"visual only, invasive inspection n/a replace sealant, seal splits/cracks at flashing"|"1"|"E"|"1997"|"50"|"0"|"repair cracks"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"S"|"1975"|"10"|"0"|"replace kitchen door"|"1"|"E"|"1975"|"50"|"0"||"1"|"S"|"1975"|"50"|"0"||"1"|"1"|"S"|"1999"|"5"|"0"|"replace main distribution gear"|"1"|"S"|"2003"|"10"|"0"||"1"|"1"|"S"|"1990"|"5"|"0"|"Replace building clock system"|"1"|"S"|"2006"|"20"|"0"|"rec center pool system replaced 2006"|"1"|"INSTRUCT"|"S"|"2002"|"5"|"97356"|"Replace carpet"|"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"15"|"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1975"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"graffitti clean up residue discolors masonry"|"S"|"1975"|"50"|"0"||"0"|||||"0"||"1"|"CONCRETE"|"S"|"1975"|"50"|"0"|"replace sealant at joints"|"S"|"S"|"1"|"1"|"1975"|"50"|"0"|"replace double wood doors"|"1"|"S"|"1975"|"10"|"0"|"replace missing rail"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1975"|"5"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"1"||"S"|"2000"|"5"|"0"|"visual only, invasive inspection n/a replace sealant, seal splits/cracks at flashing"|"0"|||||"0"||"1"|"COPPER"|"S"|"1975"|"15"|"0"|"classroom sinks tested positive for lear in two wings of school suggest replacing branches and mains serving classrooms in wings"|"1"|"IRON"|"S"|"1975"|"10"|"0"|"sanitary drainage below floor of one set of boys and girls gang toilet rooms may have been damaged below floor resulting in sewafe backups. Suggest replacement of all sanitary piping below toiler room floors"|"1"|"OTHER"|"S"|"1999"|"15"|"0"|"500 gallon hot water storage tank connected to heat exchanger fed from HVAC boiler year round"|"1"|"S"|"1999"|"20"|"0"|"replace misc. fixtures throughout building"|"1"|"CV,DD_MZ"|"1"|"BOILERWATE"||"E"|"2009"|"30"|"0"|"replaced in 2009"|"1"|"E"|"2009"|"35"|"0"|"replaced in 2009 with boiler"|"1"|"E"|"1999"|"20"|"0"|"installed in 1999 - chillers"|"1"|"S"|"2008"|"25"|"0"|"AHU's installed new in 2008"|"1"|"S"|"2009"|"25"|"0"|"piping replaced with boiler in 2009"|"1"|"S"|"2008"|"28"|"0"|"cleaned ductwork in 2008"|"1"|"S"|"2009"|"12"|"0"|"Upgraded with boiler install in 2009"|"1"|"S"|"2000"|"5"|"0"|"complete system replacement with pt. addressible type"|"1"|"S"|"2000"|"5"|"0"|"complete system replacement with pt. addressible type"|"0"|"S"|||"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"2008"|"20"|"0"|"Installed new in 2008"|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,OTHER"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS"||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"1,624,786"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/30/2010 1:31:35 PM| 779|"Kenmore-Tonawanda UFSD"|"14260103"|"Hoover Elementary"|"0006"|"08/20/2010"|"199 THORNCLIFF RD "|"BUFFALO "|" 14223"|"ANNUAL"|"07/01/2011"|"1950"|"106,292"|"2"|"5"|"0"|"DISTRICT"|"INSTRUCT"||"607"|"K,1,2,3,4,5"|"0"|"1"|"1"|"607"|"0"|"0"|||"20"|"17,517"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"18,000"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1950"|"1"|"50,000"|"Backflow Preventer & External Enclosure for domestic water."|"1"|"MUN_UTILIT"|"S"|"1950"|"12"|"0"||"1"|"S"|"1950"|"1"|"6,000"|"Install fence around gas meter setting."|"1"|"UTIL"|"BELOW"|"S"|"2003"|"25"|"0"||"1"|"S"|"1967"|"6"|"0"||"0"||||"0"||"1"|"S"|"1995"|"5"|"25,000"|"Replace existing catch basins, piping and regrade existing catch basins."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"15"|"0"||"1"|"CONCRETE"|"S"|"2004"|"10"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1950"|"15"|"0"||"1"|"S"|"1950"|"15"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"2004"|"5"|"150,000"|"Replace ceilings in the corridors and gymnasium."|"1"|"S"|"2004"|"20"|"0"||"1"|"S"|"S"|"2004"|"5"|"75,000"|"Replace hardware with lever locksets and replace doors at stairhalls."|"1"|"S"|"1950"|"15"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2002"|"1"|"263,000"|"Replace older vintage panelboards and old building wiring."|"1"|"S"|"2002"|"5"|"289,000"|"Replace Auditorium theatrical lighting system & house lighting. Replace various interior & exterior light fixtures."|"1"|"1"|"U"|"2003"|"0"|"300,000"|"Replace clock system, Auditorium sound system, add assistive listening system and upgrade telephone system."|"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1995"|"10"|"0"||"1"|"COMMON"|"S"|"1995"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1950"|"5"|"80,000"|"Replace wood floor in the gymnasium."|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1950"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"|"None"|"1"|"1"|"0"|"0"|"0"|"None"|"S"|"2008"|"3"|"100,000"|"Masonry Restoration Required. Replace misc. brick, repoint & regrout masonry."|"1"|"MASONRY"|"S"|"1950"|"5"|"75,000"|"Replace with new SS liner, replace brick, repoint & regrout 75%."|"0"|||||"0"||"S"|"S"|"0"|"1"|"1985"|"5"|"50,000"|"Replace exterior doors and replace security system motion sensors."|"1"|"S"|"1985"|"3"|"50,000"|"Replace & repair existing concrete stairs."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1985"|"10"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2008"|"20"|"0"||"1"|"PLASTIC"|"S"|"2008"|"20"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1950"|"8"|"0"||"1"|"IRON,GALVANIZED,COPPER,LEAD"|"S"|"1950"|"1"|"65,000"|"Upgrade Kitchen plumbing."|"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"2004"|"1"|"384,000"|"Replace classroom sinks & lavs, renovate locker rooms, replace corridor drinking fountains with ADA Electric Water Coolers, replace wall hydrant with non freeze vacuum breaker type, hose bibb for gang lavs."|"1"|"VAV"|"1"|"BOILERSTEA"||"S"|"2002"|"6"|"0"||"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"S"|"2002"|"3"|"1,100,000"|"Replace unit vents, air handling units, relief hoods & exhaust fans."|"1"|"S"|"1985"|"3"|"200,000"|"Replace misc. piping and valving."|"1"|"S"|"1985"|"3"|"92,000"|"Internally clean ductwork."|"1"|"S"|"2002"|"3"|"300,000"|"Update Controls with new equipment."|"1"|"S"|"2003"|"0"|"30,000"|"Provide additional code required notification signals."|"1"|"S"|"2003"|"0"|"16,000"|"Provide additional code required smoke detection."|"1"|"S"|"1950"|"1950"|"250,000"|"Reconstruction Work at Stage - install new sprinkler system for stage."|"1"|"S"|"1950"|"0"|"110,000"|"Provide additional exit signage, interior & exterior emergency lighting."|"1"|"U"|"1950"|"0"|"178,000"|"Replace Emergency Generator and Distribution System."|"1"|"0"|"125,000"|"Provide ADA accessibility in locker rooms and additional ADA accessible exterior entrances."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"FAIR"||"5,250,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 1:34:41 PM| 781|"Three Village CSD"|"58020106"|"North Country Learning Center"|"0018"|"8/26/10"|"100 Suffolk Avenue"|"Stony Brook"|" 11790"|"ANNUAL"|"5/1/11"|"1963"|"73,990"|"1"|"3"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"ADMIN"||"1"|"0"|"0"|"2"|"6,000"|"S"|"1997"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"15"|"0"|"New RPZ installed"|"1"|"SITESEPT"|"S"|"2008"|"15"|"0"||"1"|"E"|"2008"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2008"|"25"|"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"15"|"175,000"|"Existing rear parking lot in need of replacement"|"1"|"CONCRETE,ASPHALT"|"S"|"2008"|"15"|"0"||"0"||||"0"||"1"|"S"|"2009"|"12"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1963"|"25"|"0"||"1"|"S"|"1963"|"15"|"16,000"|"Several int masonry & ceramic tile cracks should be monitored, also areas in need of attention. Spalling concrete plank roof deck. "|"1"|"S"|"1963"|"15"|"125,000"|"Recommend abuse resistant sheetrock & paint be installed over existing corridor ceramic tile walls. Install chair rail at top of sheetrock & paint."|"1"|"S"|"2008"|"15"|"21,000"|"Many ceilings replaced as part of building conversion. Repair plaster ceiling in Fan Room as well as rear boiler room & storage sheetrock ceiling."|"0"||||"0"||"1"|"S"|"S"|"2008"|"15"|"159,750"|"Recommend replacement of int doors on priority basis. Replace doorknobs w/ lever type hardware."|"1"|"S"|"1963"|"25"|"0"||"0"||||"0"||"1"|"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"1"|"E"|"2008"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"E"|"2008"|"12"|"0"||"1"|"COMMON"|"E"|"2008"|"15"|"0"||"1"|"COMMON"|"S"|"1963"|"25"|"0"||"1"|"COMMON"|"S"|"1963"|"12"|"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1963"|"25"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"1"||"S"|"1963"|"25"|"0"|"Ext masonry reconstruction & miscellaneous steel lintel replacement is required at multiple locations. Brick quoins are in need of attention. Repair existing cupola. Rake out & recaulk ext control & expansion joints."|"1"|"MASONRY"|"S"|"1963"|"15"|"18,000"|"Repoint chimney at front boiler room."|"0"|||||"0"||"S"|"S"|"1"|"1"|"2010"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1995"|"10"|"16,000"|"Recommend building-wide counterbalance replacement. Long range plan to replace windows."|"OTHER"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"5"|"722,000"|"Flat roofs replaced in 2009. Asphalt shingle roofs, gutters & leaders in need of replacement."|"0"|||||"0"||"1"|"GALVANIZED"|"S"|"1963"|"15"|"0"||"1"|"IRON"|"S"|"1963"|"15"|"0"||"1"|"OIL"|"S"|"2009"|"15"|"30,000"|"Replace hot water heater in front boiler room"|"1"|"S"|"2010"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2008"|"20"|"550,000"|"Recommend replacement of boiler & boiler room equipment in front of boiler room & improve biler room ventilation in both boiler rooms"|"1"|"S"|"2008"|"20"|"0"|"Recommend replacement of boiler & boiler room equipment in front of boiler room & improve boiler room ventilation in both boiler rooms"|"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"E"|"2007"|"2007"|"0"|"Waterless fire suppression system in NOC"|"1"|"S"|"2007"|"15"|"0"||"1"|"E"|"2007"|"20"|"0"||"1"|"1"|"140,000"|"Renovate 1 set of men's & women's toilets for handicapped accessibilty"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"COMMSYS,HVAC,FIREALARM,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"|"0"|"1"||"GOOD"||"1,972,750"|"S"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson"|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/30/2010 1:56:51 PM| 782|"Gowanda CSD"|"04280106"|"Jr / Sr High Scool"|"0001"|"09/15/2010"|"10674 Prospect Street"|"Gowanda"|" 14070"|"ANNUAL"|"07/01/2011"|"1956"|"271,000"|"2"|"12"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"857"|"5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"857"|"0"|"0"|||"50"|"38,973"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2005"|"25"|"0"||"1"|"S"|"1993"|"5"|"40,000"|"Replace existing dual gas meter and regulator set."|"1"|"UTIL"|"BELOW"|"S"|"2001"|"5"|"60,000"|"Provide additional site/security lighting."|"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"15"|"825,000"|"REconstruct driveways and parking; replace Thatcher Brook bridge."|"1"|"CONCRETE"|"S"|"2001"|"5"|"100,000"|"Replace sidewalks."|"0"||||"0"||"1"|"S"|"2007"|"15"|"80,000"|"N"|"Upgrade athletic fields."|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"20"|"150,000"|"Replace original 1955 lockers."|"1"|"S"|"S"|"1956"|"5"|"200,000"|"Replace all corridor doors, hardware and paint frames."|"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"1"|"S"|"2001"|"5"|"65,000"|"Replace 1960's panelboards, feeders and starters."|"1"|"S"|"2001"|"3"|"120,000"|"Replace T-12 fixtures and incandescents."|"1"|"1"|"S"|"2001"|"5"|"760,000"|"Replace PA, clock and telephone systems."|"1"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"350,000"|"Abate VAT and install VQT."|"1"|"COMMON"|"S"|"2002"|"25"|"0"||"1"|"INSTRUCT"|"S"|"2002"|"30"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"30"|"350,000"|"Masonry restoration."|"1"|"CONCRETE"|"S"|"1956"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"10"|"180,000"|"Reduce original 1955 and 1968 exterior doors."|"1"|"S"|"2002"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"20"|"200,000"|"Replace window wall systems at 1955 and 1968 wings."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"20"|"100,000"|"Reconstruct roof areas."|"1"|"PLASTIC"|"S"|"2007"|"20"|"0"|"Included in number 68U."|"1"|"GALVANIZED,COPPER"|"S"|"2001"|"5"|"25,000"|"Install shut off valves through out system."|"0"|"IRON,PVC"|"S"|"2001"|"5"|"75,000"|"Replace deteriorated piping."|"1"|"NAT_GAS"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"5"|"200,000"|"Replace fixtures and trim in six toilet rooms and trim in four toilet rooms."|"1"|"CV"|"1"|"BOILERWATE"||"S"|"2006"|"25"|"0"||"0"|"S"|"2001"|"20"|"0"||"1"|"S"|"2006"|"5"|"560,000"|"Replace original roof top unit."|"1"|"S"|"2006"|"5"|"195,000"|"Replace exhaust fans and relief hoods. Upgrade ventilation."|"1"|"S"|"2006"|"5"|"90,000"|"Add valvew in crawlspace for hot water and glycol systems."|"1"|"S"|"2006"|"20"|"0"||"1"|"S"|"2006"|"5"|"50,000"|"Add DDC alarms at walk-in coolers/freezers. Add DDC controls to exterior lighting."|"1"|"S"|"2001"|"5"|"140,000"|"Upgrade control panel and devices."|"1"|"S"|"2001"|"1"|"70,000"|"Replace/upgrade devices."|"1"|"S"|"2001"|"2001"|"0"||"1"|"S"|"2001"|"1"|"50,000"|"Upgrade emergency lighting to meet code."|"1"|"S"|"2001"|"1"|"90,000"|"Segregate emergency life safety loads."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"1"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SUMPPUMP,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"||"5,125,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/30/2010 2:01:06 PM| 783|"East Syracuse-Minoa CSD"|"42040106"|"Park Hill School"|"0003"|"08/31/2010"|"ROBY AVENUE "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/2010"|"1938"|"36300"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT,OTHER,OTHER_ORG"|"Adult Ed/Cont Ed/Special Ed"|"342"|"Pre-K"|"0"|"1"|"1"|"342"|"0"|"0"|||"9"|"7200"|"ADMIN,CAFE,KITCHEN,PREK"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1962"|"15"|"0"||"1"|"S"|"1962"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2009"|"30"|"0"|"Upgraded site lighting w/ "Safe + Sound' project."|"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2006"|"5"|"437000"|"Bus loop and loading dock drive asphalt need replacement."|"1"|"CONCRETE,ASPHALT"|"U"|"2006"|"5"|"175000"|"Bus loop sidewalks need replacement."|"1"|"S"|"2000"|"20"|"0"||"1"|"S"|"1962"|"20"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"40"|"0"|"Minor settlement cracks."|"1"|"S"|"2009"|"40"|"0"|"Interior plaster repair w/ EXCEL funds."|"1"|"S"|"1962"|"40"|"0"||"1"|"U"|"1962"|"5"|"125000"|"Recommend replacing ceiling tile in throughout the building."|"0"||||"0"||"1"|"U"|"U"|"1962"|"5"|"262000"|"Recommend replacing original doors and hardware."|"1"|"S"|"1962"|"30"|"0"||"1"|"S"|"2009"|"50"|"0"|"Installed w/ EXCEL funds."|"1"|"1"|"U"|"1962"|"5"|"192000"|"Recommend adding receptacles in classrooms. Replace MDP and Branch Panelboards."|"1"|"E"|"2009"|"30"|"0"|"Replaced w/ Energy Performance Contract."|"1"|"1"|"S"|"2009"|"20"|"0"|"Upgraded w/ "Safe + Sound" project (Access control; CCTV) Owner to replace broken PA system."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2009"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2006"|"10"|"0"||"1"|"COMMON"|"S"|"1962"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1962"|"10"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"40"|"0"||"CONCRETE,MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"1"|"Deterioration of Stone Sills"|"U"|"2009"|"5"|"40000"|"Recommend repairing stone sills and miscellaneous brick re-pointing(various areas)."|"1"|"MASONRY"|"U"|"1938"|"5"|"5000"|"Recommend brick re-pointing at chimney."|"1"|"MASONRY"|"E"|"2009"|"50"|"0"|"Replaced w/ EXCEL funds."|"E"|"E"|"0"|"1"|"2009"|"30"|"0"|"Upgraded w/ EXCEL funds."|"1"|"S"|"1962"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2009"|"30"|"0"|"Replaced w/ EXCEL funds."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"0"||"U"|"2003"|"5"|"357000"|"Recommend replacing the Annex portion of roof."|"1"|"PLASTIC"|"S"|"2003"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1962"|"10"|"0"||"1"|"IRON"|"S"|"1962"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2010"|"15"|"0"||"1"|"U"|"2009"|"5"|"44000"|"Majority of fixtures in poor condition; ADA fixtures replaced in 2009"|"0"||"1"|"BOILERWATE"||"E"|"2009"|"50"|"0"|"Replaced w/ Energy Performance Contract. Cast Iron, HB-Smith, 28 HE 3,050 MBH output each."|"1"|"S"|"1962"|"15"|"0"||"1"|"U"|"1980"|"5"|"26000"|"Replace ground floor unit."|"1"|"U"|"1962"|"5"|"1067000"|"Recommend replacing original equipment (UV; exhaust; AHU's) - nearing end of useful life"|"1"|"S"|"1962"|"15"|"0"||"1"|"S"|"1962"|"15"|"0"||"1"|"E"|"2009"|"30"|"0"||"1"|"E"|"2009"|"30"|"0"|"Replaced w/ "Safe + Sound" project."|"1"|"E"|"2009"|"30"|"0"|"Replaced w/ "Safe + Sound" project."|"0"||||"0"||"1"|"S"|"2009"|"15"|"0"|"Corridors have battery packs and LED exits."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"|"Upgrade in 2008"|"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"1"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||"WARMING"||"1"||"FAIR"||"2870000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 2:06:17 PM| 784|"Chittenango CSD"|"25160106"|"Bus Garage"|"5007"|"06/28/2010"|"1853 New Boston Road"|"Chittenango"|" 13037"|"ANNUAL"|"09/01/2011"|"1963"|"8425"|"2"|"0"|"1"|"DISTRICT"|"OTHER"|"Transportation Maintenance and Repair"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|||"1"|"2"|"8000"|"0"|"0"|"S"|"1992"|"2"|"1,500"|"Test tanks for integrity."|"1"|"MUN_UTILIT"|"S"|"1965"|"5"|"0"||"1"|"SITESEPT"|"S"|"1985"|"20"|"0"|"When municipal connection becomes available, sanitary line connection should be made."|"1"|"S"|"1985"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1961"|"0"|"30,000"|"Overhead service lateral conductors have exceeded its useful life. Replace with new."|"0"||||"0"||"1"|"U"|"2005"|"55"|"2,000"|"Remove debris from drainage swale at north edge of bus facility to provide positive drainage for storm water."|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2005"|"0"|"295,777"|"Patch, fill cracks, seal and restripe. Driver parking area at south end of site 17,900 SF and area adjacent to Lakeport Road. Remove 50,000 SF of existing ashpalt and replace with heavy duty asphalt."|"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"1996"|"10"|"0"||"1"|"S"|"1989"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"1961"|"0"|"177,000"|"Power distribution, circuitry, and majority of wiring devices have all exceeded their expected useful life, replace with new. Replace power panels. Provide new pole mount lighting. Replace power to HVAC equipment."|"1"|"S"|"2008"|"18"|"64,000"|"Replace bus wash bay lighting fixtures with new. Replace building mount exterior fixtures and circuitry with new."|"0"|||||"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1996"|"15"|"0"||"1"|"COMMON"|"S"|"1996"|"15"|"0"||"1"|"COMMON"|"S"|"1996"|"15"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"1"|"S"|"1990"|"25"|"201,500"|"Clean and reinforce metal deck below second floor. Paint bottom of deck for protection against bus wash spray. Patch edge of concrete around grating openings."|"MASONRY"|"1"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1996"|"25"|"3,000"|"Route out and caulk cracks. Repaint CMU in wash bay."|"1"|"METAL"|"S"|"1996"|"15"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1996"|"15"|"0"||"0"||||"0"||"1"|"S"|"1"|"1996"|"15"|"0"||"1"|"ALUMINUM,VINYL"|"S"|"Y"|"1996"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"25"|"0"|"Roof replacement Summer of 2010."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1985"|"15"|"9,500"|"Add backflow preventors, isolation valves."|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1985"|"15"|"31,500"|"Replace/repair bus wash waste water reclaim system. Add spill containments."|"1"|"NAT_GAS"|"S"|"2004"|"10"|"8,000"|"Replace heater with ASME constructed unit."|"1"|"S"|"1985"|"10"|"37,500"|"Replace outdated fixtures. Add emergency fixtures."|"0"||"1"|"FURNACE"||"S"|"1963"|"5"|"15,000"|"Replacement of gas fired unit heaters recommended. Look into more energy efficient system."|"1"|"S"|"1963"|"5"|"0"||"1"|"S"|"2004"|"10"|"0"||"1"|"S"|"1963"|"5"|"20,000"|"Upgrade existing exhaust and provide radiant heating for make up air."|"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"20,000"|"Tie into the district's temperature control system recommended for safety, comfort and energy control. Have EM cabinet in place, need tie-in."|"1"|"S"|"1990"|"0"|"20,000"|"System as reached the end of its useful life. Replace with new."|"1"|"S"|"1985"|"0"|"0"|"Replace system. Cost included in Item 82."|"1"|"S"|"1985"|"1985"|"3,000"|"Add fire extinguishers and cabinets."|"1"|"S"|"1985"|"2"|"34,000"|"Exits and emergency fixtures are not functioning correctly. Replace fixtures and circuitry with new LED lighting. Circuitry to be segregated per current NEC. Provide egress EM lighting."|"1"|"S"|"1985"|"0"|"30,000"|"Replace generator receptacle and EM panel with new NFPA Life Safety Level 2 compliant generator and distribution."|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"FAIR"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"1,302,310"|"S"|"1"|"Tetra Tech Architects and Engineers"|"10 Brown Road, Ithaca, New York 14850"|"607-277-7100"|"info@tetratech.com"|"Scott Duell"|"022982"|"I ACCEPT"|12/30/2010 2:08:43 PM| 786|"BOCES Genesee Valley (Gen-Liv-Steu-)"|"24900000"|"MUNSON ST MAINTENANCE BLDG "|"8037"|"09/08/2010"|"80 MUNSON ST "|"LEROY "|" 14482"|"ANNUAL"|"08/01/2011"|"1935"|"440"|"1"|"0"|"0"|"LSD_DIST"|"OTHER"|"Storage"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1990"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1935"|"50"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|"COMMON"|"S"|"1935"|"20"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1935"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1935"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1985"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"1935"|"10"|"0"||"CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1985"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"0"|"GOOD"||"0"|"S"|"1"|"Habiterra Architecture and Landscape Architecture P.C."|"1279 North Main Street, Jamestown, New York, 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter"|"0232261"|"I ACCEPT"|12/30/2010 2:12:06 PM| 787|"Kenmore-Tonawanda UFSD"|"14260103"|"Crosby Athletic Complex"|"7023"|"09/15/2010"|"136 CROSBY AVE "|"KENMORE "|" 14217"|"ANNUAL"|"07/01/2011"|"1947"|"11,075"|"1"|"1"|"0"|"DISTRICT"|"OTHER"|"Athletics, Stadium and Maintenance"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"1"|"2,000"|"0"|"0"|"S"|"1994"|"7"|"0"||"1"|"MUN_UTILIT"|"S"|"1947"|"7"|"168,000"|"New hydrant on east side of building, new backflow preventer & exterior enclosure for Irrigation System and Maintenance Building."|"1"|"MUN_UTILIT"|"S"|"1947"|"10"|"0"||"1"|"S"|"1947"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1994"|"6"|"0"||"1"|"U"|"1947"|"3"|"72,000"|"Replace storm water sewer for Stadium walkway."|"0"||||"0"||"1"|"S"|"1994"|"5"|"15,000"|"Replace existing catch basins."|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"6"|"0"||"1"|"ASPHALT"|"S"|"2004"|"6"|"0"||"0"||||"0"||"1"|"S"|"1987"|"2"|"75,000"|"N"|"Regrade Athletic Fields - Football Practice Fields."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1947"|"20"|"0"||"1"|"S"|"1980"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"1950"|"3"|"10,000"|"Remove deteriorated ceilings and install new ceilings."|"1"|"S"|"1970"|"5"|"20,000"|"Replace existing lockers in the team rooms."|"1"|"S"|"S"|"1989"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"1993"|"0"|"65,000"|"Add GFCI receptacles and replace older vintage electrical panelboards."|"1"|"S"|"1993"|"3"|"95,000"|"Replace various old interior & exterior light fixtures."|"1"|"1"|"S"|"1993"|"3"|"20,000"|"Provide assistive listening system on the field sound system."|"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1975"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1947"|"20"|"0"||"MASONRY"|"0"|"0"|"None"|"1"|"0"|"0"|"1"|"0"|"None"|"S"|"1965"|"3"|"25,000"|"Existing cmu waterproofing & sealing required."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"3"|"25,000"|"Replace all exterior doors."|"1"|"S"|"2004"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"1965"|"10"|"0"||"OTHER"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"2005"|"5"|"100,000"|"Replace all old built-up roofs."|"0"|||||"0"||"1"|"COPPER"|"S"|"1947"|"1"|"7,000"|"Replace piping insulation in missing areas."|"1"|"IRON,COPPER"|"S"|"1947"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1995"|"5"|"35,000"|"Replace hot water heaters, piping and accessories."|"1"|"S"|"1947"|"5"|"53,000"|"Renovate toilet rooms to meet ADA codes."|"0"||"1"|"BOILERWATE"||"S"|"1986"|"5"|"100,000"|"Replace Boiler and accessories."|"1"|"S"|"1947"|"7"|"0"||"0"||||"0"||"1"|"S"|"1985"|"5"|"150,000"|"Replace / add exhaust fans and add make-up air ventilation."|"1"|"S"|"1947"|"5"|"50,000"|"Replace pumps, misc. piping and radiant heaters."|"1"|"S"|"1985"|"6"|"0"||"1"|"S"|"1947"|"6"|"0"|"Update Controls with new equipment."|"0"|"U"||"0"|"15,000"|"Recommend installation of a new fire alarm system."|"0"||||"0"||"0"||||"0"||"1"|"S"|"1947"|"0"|"32,000"|"Provide additional exit signage, interior & exterior emergency lighting."|"0"||||"0"||"1"|"1"|||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"POOR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"FAIR"||"1,150,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 2:16:58 PM| 789|"Rochester City SD"|"26160001"|"George Forbes School #4"|"0004"|"04/23/10"|"198 BRONSON AVENUE "|"ROCHESTER "|" 14611"|"ANNUAL"|"07/01/2010"|"1935"|"69908"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"390"|"K,1,2,3,4,5,6"|"0"|"0"|"0"|"390"|"0"|"0"|||"32"|"23242"|"ADMIN,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,LIBBRARY"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1970"|"20"|"0"||"1"|"S"|"1970"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2006"|"20"|"0"|"more lighting needed around building"|"1"|"S"|"1991"|"25"|"0"|"provide drainage improvements where necessary"|"0"||||"0"||"1"|"S"|"1991"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1991"|"5"|"117000"|"full depth reconstruction of parking lot"|"1"|"CONCRETE,ASPHALT"|"S"|"1991"|"5"|"0"|"sidewalk replacement and grate replacement"|"1"|"S"|"1991"|"5"|"65000"|"provide resilient surface"|"1"|"S"|"1991"|"20"|"0"|"N"|"Fence replacement at 4', and 6' height where required"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"45"|"0"||"1"|"S"|"1972"|"45"|"0"||"1"|"S"|"2003"|"45"|"0"||"1"|"S"|"2003"|"5"|"0"||"1"|"S"|"1935"|"2"|"0"||"1"|"S"|"S"|"2003"|"5"|"0"||"1"|"S"|"1970"|"45"|"0"||"1"|"S"|"1999"|"45"|"0"||"1"|"1"|"S"|"2009"|"5"|"0"|"replace remaining federal pacific panels"|"1"|"S"|"2003"|"15"|"0"||"1"|"1"|"S"|"2009"|"10"|"0"|"POE LAN hardware ad PA new in 2009"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2003"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"15"|"0"||"1"|"COMMON"|"S"|"2003"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"45"|"0"||"MASONRY"|"1"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"1999"|"45"|"0"|"repoint sandstone, repoint 500 SF brick"|"1"|"MASONRY"|"S"|"1935"|"15"|"0"||"1"|"MASONRY"|"S"|"1999"|"45"|"0"||"S"|"S"|"1"|"1"|"1999"|"5"|"0"|"5 doors should be replaced rusting"|"1"|"S"|"1972"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1978"|"2"|"0"|"single pane windows should be upgraded for efficiency"|"OTHER"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"5"|"0"||"1"|"GLASS"|"S"|"1999"|"5"|"0"||"1"|"COPPER"|"S"|"2004"|"45"|"0"|"replace domistic booster pump"|"1"|"IRON,COPPER"|"S"|"1970"|"10"|"0"|"clean debris from 20 window wells that floor in hard rain. Drains in wells are clogged"|"1"|"NAT_GAS"|"E"|"2008"|"15"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||"1"|"BOILERSTEA"||"S"|"2006"|"30"|"0"|"boiler and feed pumps new in 2006"|"1"|"S"|"2006"|"30"|"0"|"piping replaced with boiler in 2006"|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"|"replace building exhaust and relief fans"|"1"|"S"|"2006"|"25"|"0"|"pipe in boiler room new in 2006 with boiler replacement"|"1"|"S"|"2002"|"20"|"0"|"ductwork modified with UV replacement in 2002"|"1"|"S"|"2006"|"15"|"0"|"added boiler controls and system upgrade"|"1"|"S"|"2006"|"5"|"0"|"replace with point addressable add classroom strobes"|"1"|"S"|"2006"|"5"|"0"|"replace with point addressable devices"|"1"|"S"|"1969"|"1969"|"0"|"stage sprinklers"|"1"|"S"|"2003"|"15"|"0"|"flourescent luminares on generator A and S"|"1"|"S"|"2009"|"30"|"0"|"installed now 100 kw with dual ATSs"|"1"|"1"||"some classroom's 22, 23, 122, 123, 222, 223 are not accessible, they would require an elevator or other means of conveyence accessibilty improvements and two additional HC parking spaces"|"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"|"preschool is held in former kitchen"|"465700"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/30/2010 2:21:04 PM| 790|"Kenmore-Tonawanda UFSD"|"14260103"|"Administration building"|"1002"|"10/13/2010"|"1500 COLVIN BLVD "|"KENMORE "|" 14223"|"ANNUAL"|"07/01/2011"|"1953"|"22950"|"2"|"2"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"1"|"92,000"|"BACKFLOW PREVENTER AND EXTERNAL ENCLOSURE FOR DOMESTIC WATER."|"1"|"MUN_UTILIT"|"S"|"1953"|"15"|"0"||"1"|"S"|"1953"|"1"|"6,000"|"INSTALL FENCE AROUND GAS METER SETTING"|"1"|"UTIL"|"BELOW"|"S"|"2002"|"25"|"0"||"1"|"S"|"1953"|"6"|"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2010"|"20"|"0"||"1"|"CONCRETE"|"S"|"2000"|"5"|"25,000"|"REPLACE DETERIORATING AND BROKEN CONCRETE SIDEWALKS"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1953"|"15"|"0"||"1"|"S"|"1953"|"15"|"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2000"|"5"|"50,000"|"REPLACE CEILINGS IN THE CORRIDORS."|"0"||||"0"||"1"|"S"|"S"|"2000"|"10"|"0"||"1"|"S"|"1953"|"15"|"0"||"1"|"S"|"2000"|"20"|"0"||"1"|"1"|"S"|"2002"|"5"|"115,000"|"REPLACE OLDER VINTAGE ELECTRICAL PANELS AND ADDITIONAL GFCI RECEPTACLES."|"1"|"S"|"2002"|"5"|"30,000"|"REPLACE VARIOUS OLDER INTERIOR AND EXTERIOR FIXTURES."|"1"|"1"|"S"|"2002"|"1"|"40,000"|"INSTALL AREA OF RESCUE INTERCOM SYSTEM AND UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"1990"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"S"|"1953"|"10"|"0"||"MASONRY"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"1953"|"5"|"25,000"|"MASONRY RESTORATION REQUIRED."|"1"|"MASONRY"|"S"|"1953"|"2"|"40,000"|"REPLACE WITH NEW SS CAP, NEW LINER AND REPOINT MASONRY."|"0"|||||"0"||"S"|"S"|"0"|"0"|"2000"|"10"|"0"||"1"|"S"|"1953"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1997"|"12"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2006"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1953"|"1"|"6,000"|"INSTALL BACKFLOW PREVENTER ON BOILER MAKE-UP WATER."|"1"|"IRON,COPPER"|"S"|"1953"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"1"|"68,000"|"ADA UPGRADE IN TOILET ROOMS, INSTALL VACUUM BREAKER TYPE FAUCETS ON SERVICE SINKS, REPLACE WALL HYDRANT WITH NON-FREEZE INTEGRAL VACUUM BREAKER TYPE."|"0"||"1"|"BOILERWATE"||"S"|"2004"|"5"|"60,000"|"ADD STAND-BY BOILER."|"1"|"S"|"1953"|"10"|"0"||"1"|"S"|"2000"|"5"|"140,000"|"ADD AIR-CONDITIONING FOR SERVER EQUIPMENT AND ADD OFFICE PTAC'S"|"1"|"U"|"1953"|"0"|"25,000"|"REPLACE EXHAUST FANS."|"1"|"S"|"1953"|"10"|"0"||"1"|"S"|"1953"|"1"|"25,000"|"REPAIR DUCT ON ROOF."|"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2002"|"0"|"5,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION SIGNALS."|"1"|"S"|"2002"|"6"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"0"|"25,000"|"SEGREGATE LIFE SAFELY AND STAND-BY EMERGENCY LOADS PER CODE."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"||"0"|"1"||"GOOD"||"650,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN ST, WILLIAMSVILLE NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/30/2010 2:24:03 PM| 791|"East Syracuse-Minoa CSD"|"42040106"|"East Syracuse Elementary School"|"0002"|"8/3/10"|"KINNE ST "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/1/10"|"2002"|"53,000"|"2"|"3"|"1"|"DISTRICT"|"INSTRUCT,OTHER_ORG"||"337"|"K,1,2,3,4,5"|"0"|"1"|"1"|"337"|"0"|"0"|||"18"|"14,400"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"0"|"MUN_UTILIT"|"S"|"2002"|"35"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"35"|"0"||"1"|"S"|"2002"|"35"|"0"||"1"|"UTIL"|"ABOVE"|"E"|"2009"|"40"|"0"|"Site lighting updated w/ "Safe + Sound' project."|"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"MUNI"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2009"|"20"|"0"||"1"|"S"|"2005"|"25"|"0"||"1"|"S"|"2002"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"40"|"0"||"1"|"S"|"2002"|"40"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"50"|"2,000"|"Recommend extending roof access ladder to roof hatch. "|"1"|"S"|"2002"|"30"|"0"||"1"|"1"|"S"|"2002"|"25"|"0"|"Main switchboard replaced in 2002"|"1"|"E"|"2009"|"25"|"0"|"Updated w/ Energy Performance Contract"|"1"|"1"|"S"|"2009"|"15"|"0"|"Access control, phone, LAN & CCTV added w/ "Safe + Sound" project."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"U"|"2002"|"5"|"15,000"|"Recommend replacing VCT in various locations"|"1"|"COMMON"|"S"|"2002"|"20"|"0"||"1"|"INSTRUCT"|"S"|"1956"|"20"|"0"|"Refinished in 2007. Ongoing maintenance (sealing)"|"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"1"|"0"|"0"|"corrosion on structure at crawlspace"|"0"|"0"|"1"|"S"|"2002"|"50"|"0"||"CONCRETE,MASONRY"|"1"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"20,000"|" Correct water infiltration @ canopy; caulk misc areas"|"1"|"METAL"|"S"|"2002"|"30"|"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2009"|"25"|"0"|"Access control installed w/ "Safe + Sound" project."|"1"|"S"|"2002"|"30"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"20"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Original gym roof replaced w/ EXCEL Funds."|"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"30"|"0"||"1"|"IRON"|"E"|"2002"|"30"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"30"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"2002"|"30"|"0"||"1"|"E"|"2002"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"10"|"0"|"Existing notifier AFP-400 point addressable headend"|"1"|"S"|"2009"|"10"|"0"|"Gym smoke detectors updated w/ EXCEL Project."|"1"|"S"|"2002"|"2002"|"0"|"Ansul System at kitchen hood"|"1"|"S"|"2002"|"20"|"0"||"0"||||"140,000"|"Recommend adding emergency generator (lighting, boilers, kitchen hood, etc)"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"|"0"|"1"||"GOOD"||"177,000"|"S"|"1"|"King + King Architects"|"358 West Jefferson Street"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 2:26:02 PM| 792|"Williamsville CSD"|"14020306"|"Lawrence Bell Building"|"1052"|"08/06/2010"|"480 Lawrence Bell Drive"|"Williamsville"|"14221"|"ANNUAL"|"07/01/2011"|"1982"|"21700"|"2"|"0"|"0"|"DISTRICT"|"OTHER"|"Facility maintenance shops and nutritional services"|"0"||"0"|"0"|"1"|"0"|"0"|"0"|||"0"|"0"|"ADMIN,OTHER"|"storage and work bays"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1982"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1982"|"20"|"0"||"1"|"S"|"1982"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2009"|"20+"|"0"||"1"|"S"|"1986"|"10"|"0"||"1"|"S"|"1982"|"15"|"0"||"1"|"S"|"1986"|"10"|"0"||"0"||||"0"||"1"|"MUNI"||"1"|"S"|"1982"|"5"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT,GRAVEL"|"S"|"2010"|"7"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1982"|"20"|"0"||"1"|"E"|"2009"|"20"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"S"|"2009"|"17"|"0"||"1"|"S"|"1982"|"5"|"0"||"1"|"E"|"E"|"2009"|"18"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"||||"0"||"1"|"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"1"|"S"|"2009"|"20+"|"0"||"0"||||"0"||"1"|"COMMON"|"E"|"2009"|"13"|"0"||"1"|"COMMON"|"S"|"2009"|"10"|"0"||"1"|"COMMON"|"S"|"1982"|"20"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2009"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1982"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1982"|"20"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1982"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2009"|"20"|"0"||"1"|"IRON"|"S"|"2009"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2009"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20+"|"0"||"0"||||"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"19"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"S"|"1982"|"1982"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"1"||"Second floor offices not accessible"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"conference and break room"|"0"|||"1"|"1"||"Some ceiling tiles have water stains"|"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"Building staff report that filters are changed approximately 3 times per year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"||"0"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/30/2010 2:26:18 PM| 793|"Greenwich CSD"|"64080104"|"Middle Grade Building"|"0005"|"04/09/2010"|"GRAY AVE "|"GREENWICH "|" 12834"|"ANNUAL"|"01/01/2011"|"1926"|"59,460"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"322"|"3,4,5,6"|"0"|"0"|"0"|"322"|"0"|"0"|||"30"|"30,000"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"1"|"0"|"0"|"1"|"20,000"|"S"|"2007"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1926"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"20"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1999"|"10"|"0"|"Some Village sidewalks around the School are Non-Functioning and should be replaced."|"1"|"U"|"2004"|"3"|"201,400"|"Move playground across the street then pave old for parking."|"1"|"S"|"1926"|"20"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1926"|"20"|"0"||"1"|"S"|"1926"|"20"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"1"|"U"|"1999"|"10"|"54,000"|"Communication Systems are typically satisfactory (10) - the BCS has no place for Security Systems (1)."|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"3"|"35,100"|"Carpet is typically satisfactory (6) - replace library including carpet and old wood floor underneath (3)."|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"3"|"156,400"|"Resilient Tiles and Sheet Flooring are typically satisfactory (15) - the BCS has no place for replacing resilient tile flooring with wood flooring system (3)."|"1"|"COMMON"|"S"|"1999"|"15"|"0"||"1"|"COMMON"|"S"|"1926"|"10"|"0"||"SLABGRADE,OTHER"|"Wood Deck/Concrete/Metal Joist"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1926"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"20"|"0"||"1"|"MASONRY,METAL"|"S"|"2007"|"20"|"0"||"1"|"MASONRY"|"S"|"2007"|"20"|"0"||"S"|"S"|"0"|"0"|"2007"|"1"|"35,500"|"Exterior Doors are typically satisfactory (20) - replace main entrance vestibule and administration doors as part of security up-grades (1)."|"1"|"S"|"1999"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2006"|"15"|"0"||"METONMET,WOODONWOOD,CONMETMET"|"BUILTUP,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"1"|"1"||"U"|"1999"|"3"|"737,400"|"Sprayed Polyurethane Foam (SPF) over asbestos containing asphalt built-up."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1999"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"20"|"0"||"1"|"OIL,ELECTRIC"|"S"|"2005"|"10"|"0"|"2 oil and 1 electric."|"1"|"S"|"1999"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1999"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"3"|"20,200"|"Typically satisfactory (15) - replace original exhaust fans and gravity ventilators as part of roof replacement (3)."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"U"|"1999"|"1"|"150,000"|"replace original building pneumatic controls with DDC controls and integrate with campus wide energy management system."|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"U"|"2007"|"2007"|"108,100"|"Upgrade kitchen hood, fan and fire suppression system to comply with current code requirements."|"1"|"U"|"1999"|"3"|"11,500"|"Exterior side of building exits require emergency lights per current code."|"0"||||"0"||"0"|"1"|"0"|"Cost of automatic door operation needed at main entrance and administration entrance is included in BCS no. 64."|"GOOD"||"GOOD"||"1"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"4,076,800"|"U"|"1"|"St. John Architects"|"172 Ridge Street, Glens Falls, NY 12801"|"518-223-0225"|"sjarch@roadrunner.com"|"Samuel D. St. John"|"019740"|"I ACCEPT"|12/30/2010 2:27:54 PM| 794|"East Syracuse-Minoa CSD"|"42040106"|"Heman School"|"0001"|"10/12/2010"|"HEMAN ST "|"EAST SYRACUSE "|" 13057"|"ANNUAL"|"10/01/2010"|"1938"|"33700"|"3"|"0"|"0"|"PART"|"OTHER,OTHER_ORG"|"Doc Prep/Tech/TUT/HMBD"|"0"|||"0"|"1"||||||"23"|"21000"|"ADMIN,ART,CAFE,GUIDANCE,GYM,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"5"|"45000"|"Recommend updating water service to road"|"1"|"MUN_UTILIT"|"S"|"1938"|"5"|"45000"|"Recommend updating sewer service to road"|"1"|"S"|"2009"|"40"|"0"|"Upgraded w/ "Safe + Sound" project."|"1"|"UTIL"|"BELOW"|"E"|"2007"|"50"|"0"|"Installed 2007 225kVA pole mtd. xfmr. service, two main disconnects in building"|"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"1"|"S"|"2005"|"20"|"0"||"0"||||"0"||"0"|"ONSITE"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"5"|"263000"|"Recommend replacing front parking lot (poor condition)"|"1"|"CONCRETE,ASPHALT"|"U"|"2005"|"5"|"26000"|"Recommend replacing concrete sidewalks @ front & flagpole area."|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"50"|"0"|"Minor cracks & spalling (normal)"|"1"|"S"|"1973"|"50"|"0"|"Patching & painting required - See question 46"|"1"|"S"|"1973"|"50"|"25000"|"Recommend patching plaster & painting various areas (water damage)"|"1"|"S"|"1973"|"10"|"0"|"Classrooms = plaster ceilings (good condition); Some damaged ACT ceilings in corridor, etc."|"0"||||"0"||"1"|"S"|"U"|"1938"|"5"|"25000"|"Original doors; Door hardware non-ADA compliant (upgrade)"|"1"|"S"|"1938"|"50"|"0"||"0"||||"0"||"1"|"1"|"S"|"2007"|"10"|"245000"|"Recommend replacing original branch panels, wiring/feeders; MDP & MCP replaced in 2007"|"1"|"U"|"1973"|"5"|"140000"|"Replace T-12 classroom lighting, replace older corridor ltg., add occupancy detection"|"1"|"0"|"U"|"2002"|"5"|"200000"|"Replace impulse clock and call-switch style PA headend, upgrade LAN hardware"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"U"|"1987"|"5"|"20000"|"Recommend replacing carpet (poor condition)"|"1"|"INSTRUCT,COMMON"|"U"|"1950"|"5"|"100000"|"Recommend abating VAT (various classrooms); Replace VCT various areas"|"1"|"INSTRUCT"|"S"|"1938"|"25"|"0"|"Terrazzo is in great condition"|"1"|"INSTRUCT"|"S"|"1938"|"15"|"0"|"Ongoing maintenance (sealing)"|"SLABGRADE,CONCRMETAL,WOODTRUSS"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"1"|"S"|"1968"|"50"|"5000"|"Exterior loading dock platform - concrete is deteriorated"|"MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"1"|"0"|"misc caulking"|"S"|"2009"|"50"|"10000"|"Minor cracks; recommend caulking misc areas (sills, louvers, etc.)"|"1"|"MASONRY"|"S"|"1938"|"50"|"0"||"1"|"MASONRY"|"S"|"1987"|"25"|"0"||"S"|"S"|"0"|"1"|"1987"|"5"|"15000"|"Recommend replacing misc exterior doors"|"1"|"S"|"1938"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1987"|"15"|"0"||"METONMET,WOODONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"0"|"1"|"Gym skylight was in-filled"|"U"|"2002"|"5"|"455000"|"Recommend replacing main building roof system"|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"U"|"1938"|"5"|"480000"|"Replace all existing CW/HW galvanized piping and service meter, and manifold, provide protection from boilers"|"1"|"IRON,GALVANIZED"|"U"|"1973"|"5"|"210000"|"Recommend replacing remaining original galvanized sanitary, and original floor drains"|"1"|"NAT_GAS"|"U"|"2006"|"5"|"80000"|"Recommend replacing 1982 Bryan steel flex tube domestic boiler & HW storage tank & circ. pump"|"1"|"S"|"1990"|"10"|"114000"|"Recommend replacing fixtures in remaining toilet rooms, replace dishwasher"|"0"||"1"|"BOILERWATE,BOILERSTEA"||"U"|"1938"|"5"|"656000"|"Recommend replacing original boilers. (well maintained but beyond useful life)"|"1"|"U"|"1938"|"5"|"44000"|"Fuel system will be req'd for replacement w/ boiler replacement"|"0"||||"0"||"1"|"U"|"1973"|"5"|"900000"|"Recommend replacing original equipment (well maintained but beyond useful life)"|"1"|"U"|"1973"|"5"|"131000"|"Recommend replacing original piping/radiators (well maintained but beyond useful life)"|"1"|"U"|"1973"|"5"|"133000"|"Control dampers should be replaced w/ equipment upgrades"|"1"|"U"|"1973"|"5"|"231000"|"Recommend replacing original pneumatic controls"|"1"|"S"|"2007"|"15"|"0"|"Siemens point addressable system, A/Vs in proper locations"|"1"|"S"|"2007"|"15"|"0"|"Siemens point addressable device coverage is code compliant"|"0"||||"9000"|"Recommend adding fire suppression system to 6-burner range hood in kitchen"|"1"|"S"|"2007"|"10"|"0"|"Existing battery packs/LED exits in corridors maintained by owner"|"1"|"S"|"2007"|"30"|"0"|"Detroit Diesel natural gas outdoor generator and 600A ATS installed in year 2007"|"1"|"0"|"50000"||"GOOD"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"1"|"0"|"1"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"1"|"0"||||"0"|"1"|"HVAC,FIREALARM,LIGHTING"|"FULL"||"1"||"FAIR"|"District is currently in the process of leasing the building"|"4657000"|"U"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 2:31:35 PM| 795|"Riverhead CSD"|"58060204"|"Philips Ave ES-Portable Classroom #1"|"0035"|"06/04/2010"|"141 Philips Avenue"|"Riverhead"|" 11901"|"ANNUAL"|"05/01/2011"|"1999"|"3200"|"1"|"5"|"1"|"DISTRICT"|"INSTRUCT"||"90"|"Pre-K,K,1,2,3,4"|"0"|"0"|"0"|"0"|"90"|"0"|||"4"|"3200"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"39"|"0"||"1"|"SITESEPT"|"S"|"1999"|"39"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"1999"|"39"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"ASPHALT"|"S"|"1999"|"9"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"|"Repair masonry wall area in boiler room beneath windows."|"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1999"|"39"|"0"||"1"|"S"|"1999"|"9"|"0"||"1"|"1"|"S"|"1999"|"9"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"10"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1999"|"10"|"0"|"Replace damaged skirting."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1999"|"10"|"0"||"WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1999"|"39"|"0"||"1"|"IRON"|"S"|"1999"|"39"|"0"||"0"|"ELECTRIC"|"S"|"1999"|"9"|"0"||"1"|"S"|"1999"|"39"|"0"||"0"||"1"|"FURNACE"||"S"|"1999"|"9"|"0"||"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1999"|"9"|"0"||"0"||||"0"||"1"|"S"|"1999"|"39"|"0"||"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1999"|"9"|"0"||"1"|"S"|"1999"|"9"|"0"||"0"||||"0"||"1"|"S"|"1999"|"9"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"|"0"||"0"|"0"|"0"||||"0"|"0"|"FAIR"|"District would like to eliminate all portable classrooms"|"0"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"salvesen@bbsarch.com"|"Lawrence Salvesen, AIA"|"020623"|"I ACCEPT"|12/30/2010 2:34:48 PM| 797|"Kenmore-Tonawanda UFSD"|"14260103"|"Parker Athletic Complex - Fieldhouse"|"7029"|"07/14/2010"|"PARKER BLVD "|"TONAWANDA "|" 14150"|"ANNUAL"|"07/01/2011"|"1968"|"7410"|"1"|"1"|"0"|"DISTRICT"|"OTHER"|"Athletic Team Rms, Storage & Concessions"|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1968"|"1"|"69,000"|"Separate ground hydrants from domestic water. Backflow Preventer & Exterior Enclosure for domestic water."|"1"|"MUN_UTILIT"|"S"|"1968"|"10"|"0"||"1"|"S"|"1975"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1994"|"6"|"0"||"1"|"S"|"1968"|"6"|"0"||"0"||||"0"||"1"|"S"|"1975"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1968"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"15"|"0"||"0"||||"0"||"1"|"S"|"2005"|"5"|"100,000"|"N"|"Replace fence around track & regrade athletic field - football practice field."|"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"1985"|"10"|"0"||"1"|"S"|"S"|"1985"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1994"|"5"|"2,000"|"Add GFCI receptacles in various areas."|"1"|"S"|"1980"|"5"|"7,000"|"Upgrade misc. building lighting."|"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1985"|"10"|"0"||"1"|"COMMON"|"S"|"1985"|"10"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1968"|"10"|"0"||"MASONRY"|"0"|"0"|"None"|"1"|"0"|"0"|"0"|"0"|"None"|"S"|"1985"|"3"|"5,000"|"Repoint masonry and repaint building cmu."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2005"|"3"|"10,000"|"Replace all exterior doors."|"1"|"S"|"2005"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1968"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1968"|"10"|"0"||"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1968"|"5"|"50,000"|"Replace galvanized piping."|"1"|"IRON"|"S"|"1968"|"10"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"5"|"35,000"|"Replace hot water heaters, piping and accessories."|"1"|"S"|"2005"|"5"|"160,000"|"Renovate locker rooms & toilet rooms for ADA, replace shower & mixing valves, replace wall hydrant with non freeze integral vacuum breaker type."|"0"||"1"|"OTHER"|"Electric Heaters"|"U"|"1968"|"5"|"50,000"|"Replace Electric Cabinet Heaters."|"1"|"S"|"1968"|"6"|"0"||"0"||||"0"||"1"|"U"|"1968"|"0"|"250,000"|"Upgrade ventilation & exhaust to locker rooms, toilet rooms and concession."|"0"||||"0"||"1"|"S"|"1968"|"6"|"0"||"1"|"S"|"1968"|"6"|"0"||"0"|"NF"||"0"|"15,000"|"Recommend installation of new fire alarm system."|"0"||||"0"||"1"|"S"|"2004"|"2004"|"0"||"1"|"U"|"1968"|"0"|"10,000"|"Upgrade and replace Emergency Lighting."|"0"||||"0"||"1"|"0"|"100,000"|"Provide ADA accessibility to locker rooms and toilet rooms."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"POOR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"|||"0"|"1"||"FAIR"||"900,000"|"U"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 3:01:46 PM| 798|"BOCES Genesee Valley (Gen-Liv-Steu-)"|"24900000"|"ADMN SERVICES BLDG "|"8036"|"09/08/2010"|"80 MUNSON ST "|"LEROY "|" 14482"|"ANNUAL"|"08/01/2011"|"1935"|"36,200"|"3"|"2"|"1"|"LSD_DIST"|"DIST_ADMIN"||"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1935"|"5"|"$35,000"|"Add backflow preventor."|"1"|"MUN_UTILIT"|"S"|"1935"|"15"|"0"||"1"|"S"|"2010"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2007"|"15"|"0"||"1"|"S"|"1985"|"30"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"15"|"0"||"1"|"CONCRETE"|"S"|"1985"|"20"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1985"|"40"|"0"||"1"|"S"|"1985"|"25"|"$5,000"|"Repair"|"1"|"S"|"1985"|"25"|"$5,000"|"Repair"|"1"|"S"|"1985"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"1985"|"15"|"0"||"1"|"S"|"1985"|"25"|"0"||"1"|"S"|"1985"|"15"|"0"||"1"|"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"10"|"0"||"1"|"COMMON"|"S"|"1985"|"15"|"0"||"1"|"COMMON"|"S"|"1985"|"25"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1985"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1985"|"50"|"0"||"1"|"MASONRY"|"S"|"1985"|"50"|"0"||"1"|"MASONRY"|"S"|"1985"|"50"|"0"||"S"|"S"|"0"|"1"|"1985"|"15"|"0"||"1"|"S"|"1985"|"20"|"0"||"0"|||||"0"||"1"|"WOOD,WOODCLAD"|"S"|"NA"|"1985"|"20"|"0"||"METONMET,CONMETMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"20"|"0"||"1"|"PLASTIC"|"E"|"1985"|"20"|"0"||"1"|"COPPER"|"S"|"2000"|"15"|"0"||"1"|"IRON"|"S"|"2000"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"CV"|"1"|"BOILERWATE,FURNACE"||"S"|"2007"|"5"|"0"||"1"|"S"|"2007"|"15"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"2010"|"10"|"$80,000"|"Replace 30 and 25 ton RTUs"|"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2007"|"10"|"$15,000"|"Duct cleaning"|"1"|"S"|"2010"|"10"|"$55,000"|"Upgrade to DDC controls"|"1"|"S"|"1990"|"10"|"$15,000"|"Add devices to meet code"|"1"|"S"|"1990"|"10"|"$15,000"|"Add devices to meet code"|"0"||||"0"||"1"|"S"|"1990"|"10"|"$10,000"|"Add coverage to meet code"|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"0"||||"0"|"0"|"GOOD"||"0"|"S"|"1"|"Habiterra Architecture and Landscape Architecture P.C."|"1279 North Main Street, Jamestown, New York, 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter"|"0232261"|"I ACCEPT"|12/30/2010 3:04:38 PM| 799|"Gowanda CSD"|"04280106"|"Aldrich St. Elementary"|"0006"|"09/15/2010"|"450 Aldrich Street Ext."|"Gowanda"|" 14170"|"ANNUAL"|"07/01/2011"|"1967"|"77,189"|"1"|"6"|"0"|"DISTRICT"|"INSTRUCT"||"472"|"Pre-K,K,1,2,3,4"|"0"|"1"|"0"|"472"|"0"|"0"|||"39"|"31,420"|"ADMIN,ART,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2002"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2007"|"20"|"150,000"|"Reconstruct drives and parking areas."|"1"|"CONCRETE"|"S"|"2002"|"10"|"50,000"|"Replace sidewalks."|"1"|"S"|"2002"|"10"|"30,000"|"New safety surface."|"1"|"S"|"2002"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"S"|"2007"|"20"|"60,000"|"Replace interior doors and hardware at 1968 building."|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2001"|"1"|"150,000"|"Replace 1960's panelboards, feeders and devices."|"1"|"S"|"2001"|"3"|"35,000"|"Replace T-12 fixtures."|"1"|"1"|"S"|"2001"|"5"|"220,000"|"Replace PA, clock and telephone system."|"0"||||"0"||"1"|"COMMON"|"S"|"2006"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"10"|"250,000"|"Abate VAT and install VQT in classrooms."|"1"|"COMMON"|"S"|"2002"|"25"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"30"|"250,000"|"Masonry restoration."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"15"|"25,000"|"Replace entrance doors."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2002"|"15"|"375,000"|"Replace windows on 1968 building."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2007"|"15"|"0"||"1"|"PLASTIC"|"S"|"2007"|"15"|"0"||"1"|"COPPER"|"S"|"2001"|"5"|"40,000"|"Replace shut off valves."|"1"|"IRON,PVC"|"S"|"2001"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"5"|"75,000"|"Replace fixtures in nineteen classrooms."|"0"||"1"|"BOILERWATE,FURNACE"||"S"|"2001"|"20"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2001"|"5"|"175,000"|"Replace rooftop unites and split A/C systems."|"1"|"S"|"2006"|"5"|"80,000"|"Replace original Gymnasium AHUs."|"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2001"|"15"|"0"||"1"|"S"|"2006"|"5"|"25,000"|"Upgrade DDC system."|"1"|"S"|"2001"|"5"|"45,000"|"Upgrade control panel and devices."|"1"|"S"|"2001"|"1"|"25,000"|"Upgrade devices adn expand coverage."|"1"|"S"|"2001"|"2001"|"25,000"|"Upgrade fire suppression system at Kitchen."|"1"|"S"|"2001"|"1"|"40,000"|"Upgrade system."|"1"|"S"|"2001"|"1"|"50,000"|"Segregate life safety loads."|"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"GOOD"||"2,175,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|12/30/2010 3:06:27 PM| 800|"Kenmore-Tonawanda UFSD"|"14260103"|"Longfellow Building"|"3022"|"09/15/2010"|"255 MYRON AVE "|"KENMORE "|" 14217"|"ANNUAL"|"07/01/2011"|"1957"|"12450"|"1"|"1"|"0"|"DISTRICT"|"OTHER"||"0"|||"0"|"0"||||||"0"|"0"|"ADMIN,CAFE,HLTHSUITE,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"U"|"1990"|"0"|"75,000"|"INSTALL DRAIN TO EXTERIOR BELOW EXISTING BACKFLOW PREVENTER. NEW FIRE HYDRANT AT SOUTHEAST CORNER OF BUILDING."|"1"|"MUN_UTILIT"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"1"|"7,000"|"INSTALL FENCE AROUND GAS METER SETTING"|"1"|"UTIL"|"BELOW"|"S"|"1996"|"15"|"0"||"1"|"S"|"1957"|"6"|"0"||"0"||||"0"||"1"|"S"|"1957"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1993"|"3"|"125,000"|"RECONSTRUCT ASPHALT PARKING LOT SOUTH OF BUILDING."|"1"|"CONCRETE"|"S"|"1993"|"3"|"25,000"|"REPLACE DETERIORATING AND BROKEN CONCRETE SIDEWALKS."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1983"|"7"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1957"|"20"|"0"||"1"|"S"|"1957"|"20"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"2000"|"10"|"0"||"1"|"S"|"1957"|"5"|"120,000"|"REPLACE LOCKERS IN THE BOYS AND GIRLS LOCKER ROOMS."|"1"|"S"|"S"|"2000"|"1"|"7500"|"REPLACE HARDWARE WITH LEVER LOCKSETS"|"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"1993"|"0"|"120,000"|"REPLACE OLD VINTAGE PANEL BOARDS AND WIRING."|"1"|"S"|"2002"|"5"|"27,000"|"REPLACE VARIOUS OLD BUILDING LIGHT FIXTURES."|"1"|"1"|"S"|"1995"|"5"|"20,000"|"UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"COMMON"|"S"|"1985"|"3"|"5,000"|"REPLACE CARPET IN MISC. ROOMS."|"1"|"COMMON"|"S"|"1993"|"10"|"0"||"1"|"COMMON"|"S"|"1993"|"10"|"0"||"1"|"INSTRUCT"|"S"|"1957"|"3"|"6,500"|"REPLACE WOOD FLOOR IN CORNER CLASSROOM."|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"S"|"1957"|"20"|"0"||"MASONRY"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"1957"|"10"|"0"||"0"||"E"|||"0"||"1"|"METAL"|"E"|"2003"|"25"|"0"||"S"|"S"|"0"|"1"|"1957"|"3"|"35,000"|"REPLACE ALL EXTERIOR DOORS."|"1"|"S"|"1957"|"10"|"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"NA"|"1957"|"3"|"115,000"|"REPLACE ALL WINDOWS ON THE ENTIRE BUILDING."|"OTHER"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"1957"|"10"|"0"||"1"|"PLASTIC"|"S"|"1993"|"10"|"0"||"1"|"COPPER"|"S"|"1957"|"1"|"3,000"|"INSULATE HOT WATER PIPING IN THE BOILER ROOM."|"1"|"IRON,COPPER"|"S"|"1957"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1998"|"1"|"84,000"|"INSTALL NEW HOT WATER HEATERS, PIPING AND ACCESSORIES."|"1"|"S"|"1957"|"5"|"70,000"|"RENOVATE TOILET ROOMS AND LOCKER ROOMS TO MEET ADA CODES."|"0"||"1"|"BOILERWATE"||"S"|"1957"|"2"|"95,000"|"REPLACE BOILERS."|"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"1990"|"5"|"50,000"|"ADD AIR-CONDITIONING TO MISC. OFFICES."|"1"|"U"|"1990"|"3"|"206,000"|"ADD UNIT VENTS AND RELIEF HOODS."|"1"|"S"|"1957"|"5"|"45,000"|"REPLACE PUMPS AND MISC. PIPING."|"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"1957"|"10"|"0"||"1"|"S"|"2002"|"0"|"8,000"|"PROVIDE ADDITIONAL CODE REQUIRED NOTIFICATION SIGNALS."|"1"|"S"|"2002"|"0"|"6,000"|"PROVIDE ADDITIONAL CODE REQUIRED SMOKE DETECTION."|"1"|"S"|"1985"|"1985"|"10,000"|"REPLACE KITCHEN FIRE SUPPRESSION SYSTEM"|"1"|"S"|"1999"|"0"|"20,000"|"PROVIDE ADDITIONAL EXIT SIGNAGE AND VARIOUS BUILDING EMERGENCY LIGHTING."|"0"||||"0"||"1"|"0"|"35,000"|"PROVIDE ADA ACCESSIBILITY IN LOCKER ROOMS."|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"NA"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"GOOD"||"1,400,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN ST, WILLIAMSVILLE, NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/30/2010 3:16:58 PM| 801|"Rochester City SD"|"26160001"|"Dag Hammarskjold School #6"|"0006"|"07/20/2010"|"595 UPPER FALLS BLVD "|"ROCHESTER "|" 14605"|"ANNUAL"|"06/01/2011"|"1962"|"69826"|"2"|"2"|"2"|"DISTRICT"|"INSTRUCT"||"362"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"1"|"362"|"0"|"0"|||"35"|"26049"|"ADMIN,LIBBRARY,MULTIPURPO"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1994"|"20"|"0"||"1"|"S"|"2001"|"30"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"25"|"0"|"replace missing/broken lightpoles"|"1"|"S"|"1997"|"30"|"0"|"provide adequate roof leaders for mobile classrooms"|"0"||||"0"||"1"|"S"|"1997"|"25"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1997"|"5"|"313900"|"resurface and replace parking lots and entrances. Replace and repair parking lot fencing and gates. Provide adequate signage. Repair curbing"|"1"|"CONCRETE"|"S"|"2008"|"20"|"8800"|"replace east entrance to school building. Repair concrete at loading dock"|"1"|"S"|"2000"|"10"|"24050"|"resurfacing of playground surface and repair playground curbing"|"1"|"S"|"2000"|"10"|"23140"|"N"|"Repair basketball and chainlink fencing, replace gates - replace chainlink fences at parking lots."|"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"50"|"0"||"1"|"S"|"1962"|"50"|"0"||"1"|"S"|"1962"|"20"|"0"||"1"|"S"|"1962"|"5"|"0"|"areas of staining/water damage to act in want rooms"|"0"||||"0"||"1"|"S"|"S"|"1962"|"2"|"0"|"replace various doors and hardware"|"1"|"S"|"1962"|"50"|"0"|"replace treads and paint railings"|"1"|"S"|"1962"|"45"|"0"|"controls work required"|"1"|"1"|"S"|"1963"|"10"|"0"|"replace obsolete secondary panels (13) replace MDP"|"1"|"S"|"2004"|"5"|"0"|"replace building mounted lighting (19)"|"1"|"1"|"S"|"2000"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2003"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2003"|"2"|"0"|"replace classroom VAT"|"1"|"COMMON"|"S"|"2003"|"20"|"0"||"1"|"COMMON"|"S"|"2003"|"2"|"0"|"at stage"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1962"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1962"|"50"|"0"|"provide sealant at all openings and repoint brick at various locations."|"1"|"MASONRY"|"S"|"2003"|"50"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"20"|"0"||"1"|"S"|"1991"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"5"|"216000"|"replace all windows"|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"1"|"0"|"numerous areas of severe bubbling areas of roof with no drain or slope areas of sonstant ponding"|"S"|"2008"|"5"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2000"|"30"|"0"||"1"|"IRON"|"S"|"1969"|"30"|"0"||"1"|"NAT_GAS"|"S"|"2001"|"10"|"0"|"replace asbestos insulation"|"1"|"S"|"2001"|"5"|"96500"|"renovate classroom toilet rooms to be ADA complaint 2. provide trapwrap on HDCP lav. 3. replace standard faucets wtih metering type"|"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"2003"|"28"|"0"|"a carbon monoxide/gas detection system is required for the boiler room"|"1"|"S"|"2003"|"28"|"0"||"1"|"S"|"2006"|"16"|"0"|"1. exterior piping insulation is deteriorating. replace insulation and provide guard jacketing"|"1"|"S"|"2003"|"5"|"0"|"replace 1.cafe AHU with a RTU 2.gym AHU with unit 3.kitchen hood exhaust system and add additional general exhaust to kitchen. 4.toilet exhaust fans for room 137a 5.provide new hual system 6. the main office suite add ventilation to classroom "|"1"|"S"|"2003"|"10"|"460"|"1. replace faulty pump seals on pumps hwp-5 and hwp-6 2. replace original building radiation 3. replace original building convectors 4. replace original building cabinet heaters 5. replace original building unit heater"|"1"|"S"|"2003"|"15"|"30000"|"1. clean existing toilet exhaust systems 2. replace multipurpose room ductwork 3. clean cafeteria ductwork"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"1991"|"10"|"0"|"replace system in its entirety to point addressable system; add strobes in classrooms"|"1"|"S"|"1991"|"10"|"0"||"1"|"S"|"1962"|"1962"|"0"||"1"|"S"|"2000"|"10"|"0"|"add bldg mtd. exit discharge lighting to emergency and add two exterior grade exits at courtyard"|"1"|"S"|"1966"|"10"|"0"|"replace generator and transfew switch; seperate life safety life safety and equipment"|"1"|"1"|||"GOOD"||"GOOD"||"1"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"multipurpose rooms"|"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"1877780"|"S"|"0"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/30/2010 3:18:15 PM| 802|"Mt Pleasant-Blythedale UFSD"|"66080602"|"Mt. Pleasant-Blythedale School"|"0001"|"12/20/2010"|"95 Bradhurst Avenue"|"Valhalla"|" 10595"|"ANNUAL"|"03/01/2011"|"1998"|"34000"|"2"|"0"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"|"School is attached to children's hospital"|"116"|"K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"1"|"116"|"0"|"0"|||"19"|"15600"|"ADMIN,ART,GUIDANCE,HLTHSUITE,HOMECAREER,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,OTHER"|"Severely disabled room"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"28"|"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"28"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"1998"|"28"|"50000"|"Budget for upgrades"|"1"|"E"|"1998"|"28"|"0"||"0"|"S"|||"0"||"1"|"S"|"1998"|"18"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1998"|"13"|"0"||"1"|"CONCRETE"|"S"|"1998"|"13"|"0"||"1"|"S"|"2010"|"15"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1998"|"38"|"0"||"1"|"S"|"1998"|"38"|"0"||"0"|"S"|"1998"|"38"|"0"||"1"|"S"|"1998"|"18"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"13"|"0"||"1"|"S"|"1998"|"38"|"0"||"1"|"S"|"1998"|"18"|"500000"|"Budget for new proposed elevator"|"1"|"1"|"S"|"1998"|"28"|"300"|"Budget for labeling of panels"|"1"|"S"|"2007"|"13"|"1200"|"Budget for upgrades"|"1"|"1"|"S"|"1998"|"8"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"8"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"13"|"0"||"1"|"COMMON"|"S"|"1998"|"18"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1998"|"38"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"38"|"120000"|"Budget for refinishing"|"0"|||||"0"||"1"|"MASONRY"|"S"|"1998"|"38"|"0"||"E"|"S"|"1"|"1"|"1998"|"22"|"20000"|"Budget for new doors"|"1"|"E"|"1998"|"38"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1998"|"15"|"0"||"METONMET"|"BUILTUP,FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"13"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1998"|"38"|"0"||"1"|"COPPER"|"S"|"1998"|"38"|"0"||"1"|"ELECTRIC"|"S"|"2007"|"12"|"0"||"0"|"S"|"2008"|"18"|"0"||"1"|"VAV"|"1"|"BOILERWATE"||"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"10"|"0"||"1"|"S"|"1998"|"13"|"0"||"1"|"S"|"1998"|"13"|"0"||"1"|"S"|"1998"|"18"|"0"||"1"|"S"|"2008"|"18"|"0"||"1"|"S"|"2010"|"15"|"30000"|"Budget for new controls"|"1"|"S"|"1998"|"5000"|"8"|"Budget to extend system"|"1"|"S"|"1998"|"5000"|"0"|"Budget to extend system"|"1"|"S"|"1998"|"1998"|"20000"|"Budget to extend sprinklers"|"1"|"S"|"1998"|"8"|"5000"|"Budget to extend"|"1"|"S"|"2006"|"21"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"0"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,HVAC,FIREALARM,SCURITYSYS,LIGHTING"|||"1"||"GOOD"||"756500"|"S"|"1"|"TFMG Architecture PC"|"PO Box 63 Bellport NY 11713"|"6312866046"|"info@thefmgrp.com"|"Richard Searles RA"|"021614"|"I accept"|12/30/2010 3:18:25 PM| 803|"Duanesburg CSD"|"53010104"|"High/Middle School"|"0003"|"08/20/2010"|"1500 Main Street "|"DELANSON "|" 12053"|"NONE"|"06/01/2010"|"1929"|"825"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Mothballed"|"0"||"280"|"0"|"0"||||||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"NF"|"1929"|"10"|"12,000"|"Needs revised distribution to serve new layout."|"1"|"MUN_UTILIT"|"U"|"1929"|"25"|"10,000"|"Needs slight reconfiguration to serve new layout."|"0"||||"0"||"1"|"UTIL"|"ABOVE"|"U"|"1950"|"0"|"20,000"||"0"||||"0"||"1"|"S"|"1964"|"100"|"20,000"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"NONE"|"U"|"1929"|"0"|"18,000"|"New parking lot area will be required for new use."|"1"|"OTHER"|"U"|"1929"|"0"|"5,000"|"Gravel walks."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"1"|"1"|"1"|"0"|"0"|"1"|"S"|"1929"|"50"|"20,000"|"Foundation is servicable with minor masonry patch."|"0"|"U"|"1929"|"0"|"5,000"|"None exist, some will be needed for adaptive reuse."|"1"|"NF"|"1929"|"0"|"50,000"|"Walls are minimal, complete reconfiguration required for new use."|"1"|"NF"|"1929"|"0"|"7,500"|"Complete new system required for proposed new layout."|"0"||||"0"||"1"|"U"|"U"|"1929"|"0"|"5,000"|"New doors required for porposed new layout."|"0"||||"0"||"0"||||"0"||"1"|"0"|"NF"|"1950"|"0"|"20,000"|"Distribution is limited and not code compliant."|"1"|"S"|"1950"|"0"|"1,500"|"New system required for proposed new layout."|"1"|"0"|"NF"|"1950"|"0"|"2,000"|"System is disconnected."|"0"||||"0"||"1"|"COMMON"|"CF"|"1950"|"0"|"20,000"|"Floor is rotted, needs 100% replacement."|"1"|"COMMON"|"CF"|"1950"|"0"|"5,000"|"Floor is rotted, needs 100% replacement."|"0"|||||"0"||"1"|"COMMON"|"U"|"1929"|"0"|"7,500"|"Complete new system required for proposed new layout."|"WOODJOIST"||"1"|"1"|"1"|"1"|"1"|"Partial collapse."|"1"|"1"|"1"|"CF"|"1929"|"0"|"25,000"|"Wood Floor and crawl space should be replaced with slab on grade."|"MASONRY"|"1"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"1929"|"50"|"10,000"|"Stone bearing walls are servicable with minor renewal."|"1"|"MASONRY"|"NF"|"1929"|"50"|"2,000"|"Chimney is obsolete and can be covered over."|"1"|"MASONRY"|"S"|"1929"|"50"|"10,000"|"Only partial parapet exists, can be omitted with new roof."|"U"|"U"|"0"|"0"|"1950"|"0"|"5,000"|"New doors required for proposed new use."|"1"|"U"|"1929"|"50"|"7,500"|"Steps and landings are not code compliant."|"0"|||||"0"||"1"|"OTHER"|"CF"|"NA"|"2000"|"0"|"12,000"|"Some units have been boarded up."|"WOODONWOOD"|"ASPHALT"|"0"|"0"|"1"|"0"|"0"|"Fascia is rotted."|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"Fascia is missing."|"S"|"1996"|"6"|"2,000"|"Some shingles need replacement due to storm damage."|"0"|||||"0"||"1"|"IRON,COPPER"|"U"|"1929"|"0"|"10,000"||"1"|"IRON,COPPER"|"S"|"1929"|"19"|"2,000"|"Modifications are required for proposed new layout."|"1"|"ELECTRIC"|"S"|"1950"|"5"|"1,500"||"1"|"NF"|"1929"|"0"|"4,000"||"0"||"1"|"OTHER"|"Electric baseboard"|"NF"|"1950"|"0"|"10,000"|"Electric baseboard heat is inadequate."|"1"|"NF"|"1929"|"0"|"5,000"||"0"|"NF"|||"7,500"|"No a/c exists."|"0"|"NF"|||"1,500"|"No venting exists."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"NF"|"1950"|"0"|"5,000"||"0"||||"0"||"0"|"0"|"30,000"||"FAIR"|"Interior is unoccupied. Exterior is servicable."|"POOR"|"Building is mothballed."|"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"1"|"POOR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"|"Venting is through operable windows only."|"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"FAIR"|"Not currently used."|"170,000"|"U"|"1"|"Synthesis Architects, LLP"|"162 Jay Street, Schenectady, New York 12305"|"518-370-1576"|"rdefranco@synthesisllp.com"|"John Senisi"|"020640"|"I ACCEPT"|12/30/2010 3:26:42 PM| 804|"Three Village CSD"|"58020106"|"Paul J. Gelinas Jr High School"|"0008"|"8/25/10"|"25 Mud Road"|"Setauket"|" 11733"|"ANNUAL"|"5/1/11"|"1968"|"183,629"|"2"|"9"|"0"|"DISTRICT"|"INSTRUCT"||"947"|"7,8,9"|"0"|"1"|"1"|"947"|"0"|"0"|||"44"|"39,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1995"|"15"|"0"||"1"|"MUN_UTILIT"|"E"|"2007"|"20"|"0"||"1"|"SITESEPT"|"E"|"2009"|"15"|"100,000"|"Provide acid waste holding tank for existing Science Labs, as existing exterior acid neutralization tanks are no longer permitted by the SCHD."|"1"|"E"|"2009"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1968"|"7"|"0"||"1"|"E"|"2010"|"20"|"46,000"|"Ponding conditions outside Guidance Offices. Replace piping & drywell leading from 2-story cast iron roof leader. Also at south & east side of gym."|"0"||||"0"||"1"|"E"|"2010"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2010"|"15"|"0"|"Asphalt pavement reconstruction scheduled Summer 2011."|"1"|"CONCRETE,ASPHALT"|"S"|"2010"|"15"|"0"|"Sidewalks to be replaced Summer 2011."|"0"||||"0"||"1"|"E"|"2008"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"25"|"23,000"|"Several int cracks are non-structural & should be monitored."|"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"2010"|"15"|"1,072,480"|"Recommend replacement of remaining concealed spline ceilings & 2 x 4 ceilings located in the 1-story portion of the building."|"1"|"S"|"1968"|"7"|"580,000"|"Recommend replacement of all corridor & locker room lockers"|"1"|"S"|"S"|"2010"|"20"|"86,250"|"Replace closers where needed. Replace doorknobs w/ lever type hardware. Long range plan to replace int doors."|"1"|"S"|"1968"|"25"|"0"||"1"|"S"|"1968"|"20"|"0"||"1"|"1"|"S"|"1968"|"15"|"17,000"|"Infrared test main service & distribution equipment for "hot spots", clean & tighten connections, lubricate & operate as preventative maintenance."|"1"|"E"|"2010"|"15"|"0"||"1"|"1"|"E"|"2007"|"20"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"E"|"2010"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"333,000"|"Recommend replacement of remaining VAT flooring."|"1"|"INSTRUCT"|"S"|"1968"|"25"|"0"||"1"|"INSTRUCT"|"S"|"2010"|"15"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"15"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"1"|"1"||"S"|"1968"|"15"|"42,000"|"Ext masonry reconstruction & misc steel lintel replacement is required & ext control & expansion joints should be raked out & recaulked."|"1"|"MASONRY"|"E"|"2010"|"20"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"2000"|"10"|"3,400"|"Replace basement exterior door at boiler room."|"1"|"S"|"1968"|"20"|"19,000"|"Repoint exterior blue stone landings"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"10"|"0"|"Long range plan to replace windows should be considered"|"CONMETMET,OTHER"|"BUILTUP,ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"25"|"0"||"1"|"GLASS"|"E"|"2010"|"25"|"0"||"1"|"GALVANIZED"|"S"|"2010"|"15"|"0"|"On going replacement program of galvanized piping."|"1"|"IRON"|"S"|"2010"|"15"|"0"|"Exposed waste liner in fan rooms showing signitifcant rusting - monitor."|"1"|"NAT_GAS"|"E"|"2009"|"15"|"0"||"1"|"S"|"2010"|"15"|"0"||"0"||"1"|"BOILERWATE"||"E"|"2009"|"35"|"0"||"1"|"E"|"2009"|"35"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"S"|"2010"|"20"|"525,000"|"Provide mechanical fresh air ventilation. Ceiling cabinet heaters have outlined their useful life & should be replaced."|"1"|"S"|"2010"|"20"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"E"|"2007"|"15"|"0"||"1"|"S"|"1968"|"1968"|"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"1968"|"7"|"0"||"1"|"1"|"23,000"|"Several int doors do not meet handicapped accessibility. Provide handicapped facilities within locker rooms."|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT"|"0"|"0"||||"0"|"1"|"FIREALARM,SUMPPUMP,LIGHTING"|"FULL"||"1"||"GOOD"||"2,870,130"|"E"|"1"|"John A. Grillo, Architect, PC"|"1213 Main Street, Port Jefferson "|"631-476-2161"|"jmgrillo@jagarchitect.com"|"John M. Grillo"|"027360"|"I ACCEPT"|12/30/2010 3:34:34 PM| 805|"Kenmore-Tonawanda UFSD"|"14260103"|"Buildings & Grounds"|"5003"|"10/13/2010"|"1494 Colvin Blvd"|"BUFFALO "|" 14223"|"ANNUAL"|"07/01/2011"|"1954"|"16,900"|"2"|"32"|"2"|"DISTRICT"|"OTHER"|"Buildings & Grounds Dept."|"0"|||"0"|"0"||||||"0"|"0"|"NONE"||"1"|"0"|"0"|"2"|"22,000"|"S"|"1996"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1954"|"5"|"69,000"|"Install Backflow Preventer & External Enclosure for Domestic Water."|"1"|"MUN_UTILIT"|"S"|"1954"|"10"|"0"||"1"|"S"|"1954"|"10"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2002"|"25"|"0"||"1"|"S"|"1954"|"6"|"0"||"0"||||"0"||"1"|"S"|"1954"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"1990"|"10"|"0"||"1"|"CONCRETE"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1954"|"15"|"0"||"1"|"S"|"1954"|"15"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"S"|"1990"|"10"|"0"||"1"|"S"|"1954"|"15"|"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"5"|"30,000"|"Replace older vintage panelboards, add GFCI receptacles in various areas."|"1"|"S"|"2002"|"5"|"5,000"|"Upgrade lighting in various areas."|"1"|"1"|"S"|"2002"|"5"|"20,000"|"Upgrade telephone system."|"0"||||"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"1954"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"S"|"1954"|"10"|"0"||"MASONRY"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1954"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"2002"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"S"|"NA"|"1990"|"15"|"0"||"METONMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"|"None"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"None"|"S"|"1993"|"7"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1954"|"10"|"0"||"1"|"IRON,COPPER"|"S"|"1954"|"10"|"0"||"1"|"NAT_GAS"|"S"|"1990"|"5"|"87,000"|"Replace hot water heaters, piping and accessories."|"1"|"S"|"1954"|"5"|"30,000"|"Replace existing plumbing fixtures and trim."|"0"||"1"|"BOILERWATE"||"S"|"1980"|"3"|"150,000"|"Replace Boilers and accessories."|"1"|"S"|"1954"|"10"|"0"||"1"|"S"|"2005"|"15"|"0"||"1"|"S"|"1954"|"5"|"160,000"|"Upgrade garage ventilation system."|"1"|"S"|"1954"|"5"|"100,000"|"Replace garage unit heaters, pumps and misc. piping."|"1"|"S"|"1954"|"6"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"1"|"1,500"|"Add visual signals in offices."|"1"|"S"|"2002"|"7"|"0"||"0"||||"0"||"1"|"S"|"2002"|"1"|"10,000"|"Provide new battery Emergency lighting and exit signage."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"1"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"GOOD"||"750,000"|"S"|"0"|"Gordon W. Jones Associates"|"5757 Main Street, Williamsville, New York 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"Scott W. Jones"|"20434"|"I ACCEPT"|12/30/2010 3:40:24 PM| 808|"Williamsville CSD"|"14020306"|"Heim Elementary"|"0008"|"07/14/2010"|"155 HEIM ROAD "|"AMHERST "|" 14221"|"ANNUAL"|"07/01/2011"|"1966"|"74655"|"1"|"4"|"2"|"DISTRICT"|"INSTRUCT"||"677"|"K,1,2,3,4"|"0"|"1"|"0"|"677"|"0"|"0"|||"37"|"33300"|"ADMIN,ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL,RSRCEROOM,SPECED,OTHER"|"pt ot"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2000"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"10"|"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2010"|"20+"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"E"|"1966"|"10"|"0"||"1"|"S"|"1966"|"10"|"0"||"0"||||"0"||"0"|"MUNI"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"E"|"2006"|"15"|"0"||"1"|"CONCRETE"|"E"|"2006"|"15"|"0"||"1"|"E"|"2010"|"20+"|"0"|"scheduled for replacement in 2010 to 2011"|"0"||||"0"|||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"2001"|"17"|"0"||"1"|"S"|"1966"|"10"|"0"||"1"|"S"|"S"|"1992"|"17"|"0"||"1"|"S"|"1966"|"20"|"0"|"access and egress from boiler room only"|"0"||||"0"||"1"|"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"1"|"S"|"2010"|"13"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"18"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"13"|"0"||"1"|"COMMON"|"S"|"1992"|"19"|"0"||"1"|"COMMON"|"S"|"1966"|"20"|"0"||"SLABGRADE,OTHER"|"concrete on steel beams"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1992"|"20"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"1"|"1"|"1"|"0"||"S"|"1992"|"20"|"0"||"1"|"MASONRY"|"S"|"1966"|"10"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1992"|"9"|"0"||"1"|"S"|"1966"|"5"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"16"|"0"||"METONMET,OTHER"|"SINGLEPLY,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"S"|"1992"|"20"|"0"||"1"|"PLASTIC"|"S"|"1992"|"5"|"0"||"1"|"COPPER"|"S"|"1966"|"6"|"0"||"1"|"IRON"|"S"|"1966"|"6"|"0"||"1"|"NAT_GAS"|"S"|"2004"|"6"|"0"||"1"|"S"|"1966"|"5"|"0"||"0"||"1"|"BOILERSTEA,OTHER"|"Unit ventilation"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement as part of current capital project"|"1"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement as part of current capital project"|"1"|"S"|"1990"|"8"|"0"||"1"|"S"|"1991"|"6"|"0"||"1"|"S"|"1966"|"10"|"0"||"1"|"S"|"1966"|"10"|"0"||"1"|"E"|"2010"|"20+"|"0"|"Scheduled for replacement in 2011"|"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"0"|"S"|"1966"|"1966"|"0"||"1"|"S"|"1966"|"5"|"0"||"1"|"S"|"2006"|"20+"|"0"||"1"|"1"||"Accessible toilets in locker rooms only"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"1"|"HALLWAYS"||"0"|||"1"|"1"||"Ceiling tiles in hallways have some water stains"|"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"|"FRIDGE"|"WARMING"||"1"||"GOOD"||"0"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/30/2010 3:47:55 PM| 810|"Kenmore-Tonawanda UFSD"|"14260103"|"Transportation Building"|"5034"|"10/13/2010"|"1680 MILITARY RD "|"KENMORE "|" 14217"|"ANNUAL"|"07/01/2011"|"1953"|"57765"|"2"|"1"|"0"|"DISTRICT"|"OTHER"|"BUS GARAGE"|"0"|||"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"1"|"12,000"|"1"|"6,000"|"U"|"2005"|"1"|"150,000"|"UNDERGROUND TANK ABANDONED, REPLACE ABOVE GROUND TANK, PIPING AND ACCESSORIES WITH CODE COMPLIANT TANK."|"1"|"MUN_UTILIT"|"S"|"1970"|"5"|"69,000"|"INSTALL BACKFLOW PREVENTER AND EXTERNAL ENCLOSURE ON DOMESTIC WATER SERVICE"|"1"|"MUN_UTILIT"|"S"|"1970"|"15"|"0"||"1"|"S"|"1970"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"20"|"0"||"1"|"S"|"2004"|"6"|"0"||"0"||||"0"||"1"|"S"|"2004"|"10"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2004"|"10"|"0"||"1"|"CONCRETE"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"1"|"S"|"S"|"2004"|"15"|"0"||"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"2004"|"20"|"0"||"1"|"1"|"S"|"2004"|"0"|"36,000"|"PROVIDING GFCI RECEPTACLES IN VARIOUS AREAS, REPLACE OLDER VINTAGE PANEL BOARDS."|"1"|"S"|"2004"|"10"|"0"||"1"|"1"|"S"|"2004"|"5"|"15,000"|"UPGRADE TELEPHONE SYSTEM."|"0"||||"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"2004"|"15"|"0"||"1"|"COMMON"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"S"|"1970"|"10"|"0"||"MASONRY,STEEL"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2004"|"15"|"0"||"1"|"S"|"1970"|"10"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2007"|"20"|"0"||"METONMET,CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"|"NONE"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"NONE"|"S"|"2007"|"20"|"0"||"0"|||||"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1970"|"5"|"6,000"|"INSTALL BACKFLOW PREVENTER ON BOILER MAKE-UP WATER PIPING."|"1"|"IRON,COPPER"|"S"|"1970"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1970"|"1"|"87,000"|"REPLACE HOT WATER HEATERS, PIPING AND ACCESSORIES."|"1"|"S"|"1970"|"5"|"67,000"|"UPGRADE KITCHEN PLUMBING, RENOCATE 1ST FLOOR TOILET ROOMS, INSTALL ADA WATER COOLERS, FAUCETS WITH VACUUM BREAKERS ON SERVICE SINKS."|"1"|"CV"|"1"|"BOILERSTEA,OTHER"|"STEAM-TO-HOT WATER HEAT EXCHANGE"|"S"|"1970"|"3"|"375,000"|"REPLACE BOILERS AND HEAT EXCHANGER."|"1"|"S"|"1970"|"15"|"0"||"1"|"U"|"1970"|"0"|"120,000"|"REPLACE MISC. OFFICE AIR-CONDITIONING."|"1"|"S"|"1970"|"3"|"150,000"|"REPLACE EXHAUST FANS AND AIR HANDLING UNITS."|"1"|"S"|"1970"|"5"|"145,000"|"REPLACE BOILER FEED UNIT, PUMPS AND GARAGE UNIT HEATERS."|"1"|"S"|"1970"|"10"|"0"||"1"|"S"|"1970"|"3"|"61,000"|"UPDATE CONTROLS WITH NEW EQUIPMENT."|"1"|"S"|"2002"|"12"|"0"||"1"|"S"|"2002"|"6"|"0"||"1"|"U"|"1980"|"1980"|"70,000"|"INSTALL NEW FIRE SUPPRESSION AT FUEL DISPENSER."|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"0"|"10,000"|"SEGREGATE EMERGENCY AND STAND-BY LOADS PER CODES."|"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"1"|"1"|"0"|"1"|"FAIR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"GOOD"||"1,360,000"|"U"|"0"|"GORDON W. JONES ASSOCIATES, ARCHITECTS"|"5757 MAIN ST., WILLIAMSVILLE, NY 14221"|"716-633-9000"|"steve@jonesarchitects.net"|"SCOTT W. JONES"|"20434"|"I ACCEPT"|12/30/2010 3:53:15 PM| 811|"Riverhead CSD"|"58060204"|"Philips Ave ES-Portable Classroom #2"|"0036"|"06/04/2010"|"141 Philips Avenue"|"Riverhead"|" 11901"|"ANNUAL"|"05/01/2011"|"1997"|"1600"|"1"|"5"|"1"|"DISTRICT"|"INSTRUCT"||"60"|"Pre-K,K,1,2,3,4"|"0"|"0"|"0"|"0"|"60"|"0"|||"2"|"1600"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1997"|"37"|"0"||"1"|"SITESEPT"|"S"|"1997"|"37"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1997"|"37"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"1"|"ASPHALT"|"S"|"1997"|"7"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"||"1"|"S"|"1997"|"10"|"0"|"Repair masonry wall area in boiler room beneath windows."|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1997"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"1997"|"10"|"0"||"0"|||||"0"||"0"|||||"0"||"WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"15"|"0"||"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1998"|"10"|"0"|"Replace damaged skirting."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1997"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1998"|"10"|"0"||"WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1997"|"37"|"0"||"1"|"IRON"|"S"|"1997"|"37"|"0"||"1"|"ELECTRIC"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"37"|"0"||"0"||"1"|"FURNACE"||"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"S"|"1997"|"37"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"0"||"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"S"|"1997"|"7"|"0"||"0"||||"0"||"1"|"1"|||"FAIR"||"GOOD"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"0"|"0"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"0"||||"0"|"0"||||"0"|"0"|"FAIR"|"District would like to eliminate portable classrooms."|"0"|"S"|"0"|"BBS Architects and Engineer, PC"|"244 E. Main Street, Patchogue, NY 11772"|"631-475-0349"|"salvesen@bbsarch.com"|"Lawrence Salvesen, AIA"|"020623"|"I ACCEPT"|12/30/2010 3:56:12 PM| 813|"Stockbridge Valley CSD"|"25150104"|"New Bus Garage"|"5013"|"09/01/2010"|"6011 WILLIAMS RD BOX 732"|"MUNNSVILLE "|" 13409"|"ANNUAL"|"11/01/2011"|"1999"|"4000"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Bus Wash"|"0"|||"0"|"1"||||||"0"|"0"|"NONE"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"7"|"0"||"1"|"SITESEPT"|"S"|"1999"|"7"|"0"||"1"|"S"|"1999"|"7"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"E"|"2010"|"20"|"0"||"1"|"E"|"2010"|"20"|"0"||"0"|"SURFACEH2O"||"1"|"S"|||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"2010"|"10"|"0"||"1"|"ASPHALT"|"S"|"1999"|"5"|"0"|"Pads outside doors"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"|"Acoustic tile and reinforced poly vapor barier, metal liner panel"|"0"||||"0"||"1"|"S"|"S"|"2010"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1999"|"20"|"26000"|"Upgrade/Add panelboard, outlets and branch circuiting"|"1"|"S"|"1999"|"5"|"18000"|"Upgrade lamp/ballast technology, add auto controls"|"1"|"1"|"S"|"2010"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1999"|"10"|"0"||"1"|"COMMON"|"S"|"1999"|"15"|"0"|"Concrete in equipment bay, wash bay, storage areas"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1999"|"15"|"0"||"STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"5"|"3000"|"Minor rust on wash bay columns and liner panel"|"1"|"METAL"|"S"|"1999"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1999"|"5"|"30000"|"Replace OH doors"|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"1999"|"5"|"2000"|"Window not energy efficient. Replace."|"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"10"|"25000"|"Recommend coating when neoprene washers dry out"|"0"|||||"0"||"1"|"COPPER"|"S"|"1999"|"15"|"4000"|"Consider re-piping boiler make-up to discharge side of booster pump."|"1"|"IRON"|"S"|"1999"|"25"|"0"||"1"|"NAT_GAS"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1999"|"12"|"3000"|"Boiler is single Weil McLain w/Powerflame Wcrl-GO-10 burner. 68F. Add Emergnecy sw."|"1"|"S"|"1999"|"12"|"0"||"1"|"S"|"2005"|"7"|"0"|"Window AC unit in Office."|"1"|"S"|"1999"|"15"|"60000"|"Consider upgrading exhaust air systems for bays and lounge. Add CO control"|"1"|"S"|"1999"|"15"|"0"||"0"||||"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"||||"0"||"1"|"S"|"1999"|"5"|"9000"|"Replace emergency lights with self-diagnostic type units."|"0"||||"0"||"0"|"0"|"0"|"Bus garage is not intended for public access"|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"180000"|"S"|"1"|"King + King, Architects LLP"|"358 West Jefferson St, Syracuse, NY 13202"|"315-682-6180"|"jimking@kingarch.com"|"James R. King"|"015925"|"I ACCEPT"|12/30/2010 4:06:29 PM| 815|"Williamsville CSD"|"14020306"|"East High School"|"0016"|"07/26/2010"|"151 PARADISE ROAD "|"E. AMHERST "|" 14051"|"ANNUAL"|"07/01/2011"|"1975"|"216,915"|"3"|"12"|"3"|"DISTRICT"|"INSTRUCT"||"1074"|"9,10,11,12"|"0"|"1"|"1"|"1074"|"0"|"0"|||"64"|"57600"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP,OTHER"|"fitness/weight room"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1975"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2009"|"20"|"0"||"1"|"S"|"1975"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1975"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"10"|"0"||"1"|"MUNI"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"E"|"2003"|"10"|"0"||"0"||||"0"||"0"|"NF"|||"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"0"||"1"|"CONCRETE,ASPHALT"|"E"|"2003"|"10"|"0"||"0"||||"0"||"1"|"E"|"2010"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1975"|"20"|"0"||"1"|"S"|"1975"|"20"|"0"||"1"|"S"|"2010"|"19"|"0"||"1"|"S"|"2002"|"14"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"S"|"1975"|"13"|"0"||"1"|"S"|"1975"|"20"|"0"||"1"|"S"|"1975"|"15"|"0"||"1"|"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2007"|"20+"|"0"||"1"|"1"|"S"|"2010"|"20+"|"0"||"1"|"S"|"2009"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2010"|"9"|"0"||"1"|"INSTRUCT"|"S"|"1975"|"19"|"0"||"1"|"COMMON"|"S"|"1975"|"13"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1975"|"20"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"1"|"0"|"1"|"1"|"0"||"S"|"1975"|"20"|"0"||"1"|"MASONRY"|"S"|"1975"|"20"|"0"||"0"|||||"0"||"E"|"E"|"1"|"1"|"2009"|"19"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1975"|"10"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"1"|"0"||"E"|"2010"|"20+"|"0"|"roof scheduled for replacement in 2011 noted as 2010"|"1"|"PLASTIC"|"E"|"2010"|"20+"|"0"|"roof scheduled for replacement in 2011 noted as 2010"|"1"|"COPPER"|"S"|"1995"|"15"|"0"||"1"|"IRON"|"S"|"1975"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2003"|"7"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"20+"|"0"||"1"|"S"|"2002"|"20+"|"0"||"1"|"S"|"2002"|"20+"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20+"|"0"||"1"|"S"|"2002"|"20+"|"0"||"1"|"S"|"2002"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"S"|"1975"|"1975"|"0"||"1"|"S"|"1975"|"5"|"0"||"1"|"S"|"1975"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,OTHER"|"toilets lockers stair towers"|"0"|||"1"|"1"||"some ceiling tiles have water stains"|"0"|"1"|"0"|"1"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"building maintenance staff notes that filters are changed approximately 3 times a year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"|"FRIDGE"|"FULL"||"1"||"GOOD"||"0"|"S"|"1"|"Kideney Architects PC"|"200 JJ Audubon Parkway Buffalo NY"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|12/30/2010 4:07:41 PM| 816|"Rochester City SD"|"26160001"|"John Walton Spencer School #16"|"0016"|"06/25/2010"|"321 POST AVENUE "|"ROCHESTER "|" 14619"|"ANNUAL"|"06/01/2011"|"1910"|"74044"|"3"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"474"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"1"|"474"|"0"|"0"|||"35"|"25924"|"ADMIN,ART,GYM,PREK,REMEDIAL,RSRCEROOM"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1998"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"1910"|"25"|"0"||"1"|"S"|"1910"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2000"|"20"|"0"|"Parking lot lighting to be replaced in 2010"|"1"|"S"|"1988"|"25"|"0"||"0"||||"0"||"1"|"S"|"1988"|"20"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1988"|"10"|"0"|"resurface trench in parking lot"|"1"|"CONCRETE,ASPHALT"|"S"|"1988"|"5"|"0"|"resurface/widen asphalt walkways"|"1"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"|"N"|"replace perimeter chainlink fence"|"MASONCON,OTHER"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1910"|"45"|"0"||"1"|"S"|"2001"|"45"|"0"||"1"|"S"|"2001"|"45"|"0"||"1"|"S"|"2001"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1998"|"5"|"0"|"provide closers in classrooms H.C. hardware all locations"|"1"|"S"|"2001"|"10"|"0"||"1"|"S"|"2001"|"10"|"0"||"1"|"1"|"S"|"2000"|"25"|"0"|"replace obsolete secondary panels (15)"|"1"|"S"|"2004"|"15"|"0"|"replace exterior building mounted lighting replace damaged stairwell lighting."|"1"|"1"|"S"|"2002"|"10"|"0"|"building wide paging to be replaced in 2010. clocks being replaced in 2010"|"0"||||"0"||"1"|"COMMON"|"S"|"2010"|"20"|"0"|"new carpet in library (2010) carpet in main office - replace with in 3 years"|"1"|"INSTRUCT,COMMON"|"S"|"2001"|"10"|"0"|"main corridors vct - satifactory all 3 floors. 1st - floor - replace VCT in classroom 104, 2nd floor replace VCT in classroom 203, 3rd floor replace VCT in classrooms 301-304"|"1"|"COMMON"|"S"|"2001"|"10"|"0"||"1"|"COMMON"|"S"|"2001"|"10"|"0"||"SLABGRADE,WOODJOIST"||"1"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1910"|"45"|"0"||"MASONRY,STEEL"|"1"|"1"||"1"|"0"|"0"|"0"|"0"||"S"|"1993"|"45"|"0"||"1"|"MASONRY"|"S"|"1910"|"5"|"0"|"repair brick, re-point, repair cracks"|"1"|"MASONRY,METAL,OTHER"|"S"|"1910"|"10"|"0"||"S"|"S"|"0"|"1"|"1988"|"10"|"0"|"main front door replaced in 2010 CIp"|"1"|"S"|"1988"|"45"|"0"|"install handrails/replace stair nosing/ add ramp from parking lot to front entrance"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1994"|"10"|"0"|"provide new security screens"|"METONMET,WOODONWOOD"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1998"|"5"|"0"|"repair urethane roof where some damage has occured, re-seal skylights"|"1"|"GLASS"|"S"|"1998"|"5"|"0"||"1"|"COPPER"|"S"|"1980"|"45"|"0"||"1"|"IRON"|"S"|"1980"|"45"|"0"||"1"|"NAT_GAS"|"S"|"1991"|"15"|"0"||"1"|"S"|"1980"|"15"|"0"|"provide electronic FV's all urinals. Provide metering faucets all lavs."|"1"|"CV"|"1"|"BOILERSTEA"||"E"|"2010"|"35"|"0"||"1"|"S"|"2010"|"40"|"0"||"0"||||"0"||"1"|"S"|"2010"|"20"|"0"|"clean all UV's except library and gym. replace gym UV's. replace EF's."|"1"|"S"|"1965"|"20"|"0"|"provide yearly replacement of some valves steam traps"|"1"|"S"|"1998"|"15"|"0"|"clean gymnasium crilles. repair ductwork at main AHU"|"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"1998"|"5"|"0"|"replace system in its entirety to point addressable system; add strobes in classrooms"|"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"2005"|"2005"|"0"||"1"|"S"|"1998"|"10"|"0"|"replace emergency and exits in auditorium (8) add building mounted exit discharge lighting to emergency exits"|"1"|"S"|"1965"|"5"|"0"|"replace generator and transfer switch; seperate life safety adn equipment"|"1"|"1"||"New H.C. parking in 2010 CIP rear of building requires H.C. ramp for access "|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"1"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"POOR"||"1597850"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|12/30/2010 4:44:03 PM| 817|"Genesee Valley CSD"|"02070204"|"Main Building Pre-K-12"|"0012"|"06/23/10"|"1 Jaguar Drive"|"Belmont"|" 14813"|"ANNUAL"|"07/01/11"|"2002"|"208,891"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"657"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"1"|"0"|"657"|"0"|"0"|||"29"|"25,000"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LGGROUP,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"50"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"50"|"0"||"1"|"S"|"2002"|"50"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2002"|"50"|"0"||"0"||||"0"||"1"|"S"|"2002"|"50"|"25,000"|"Improve drainage near Bus Garage."|"1"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2002"|"25"|"0"|"Outfalls - open areas north of Bus Garage need minor grading."|"0"||||"0"||"1"|"S"|"2002"|"25"|"0"||"0"||||"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"CONCRETE,ASPHALT"|"S"|"2002"|"8"|"1,875,000"|"Increase parking and bus drives; add parent drop-off areas; replace flag pole; add school sign."|"1"|"CONCRETE,ASPHALT"|"S"|"2005"|"20"|"10,000"|"Add student walkway to McNinch Lane."|"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2003"|"10"|"397,500"|"N"|"Add scoreboards, irrigation, dugouts, revise tennis courts."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2002"|"50"|"0"||"1"|"E"|"2002"|"50"|"0"||"1"|"E"|"2002"|"50"|"62,500"|"Provide glazed finish in corridors at A-1 and A-2 wings; add Cafeteria acoustical treatment."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"E"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|"U"|"2004"|"5"|"1,675,000"|"Provide clean power and TVSS to reduce interruptions; provide various technology upgrades."|"1"|"S"|"2002"|"10"|"12,500"|"Replace approximately forty 2x2 fixtures with 2x4."|"1"|"1"|"S"|"2002"|"7"|"0"||"1"|"S"|"2002"|"25"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"5"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2002"|"12"|"93,750"|"Includes Elementary bleachers."|"1"|"COMMON"|"E"|"2002"|"17"|"0"||"1"|"COMMON"|"E"|"2007"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2002"|"50"|"0"||"CONCRETE,MASONRY,STEEL"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2002"|"30"|"0"||"1"|"METAL"|"S"|"2002"|"30"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"143,750"|"Replace doors in selected areas; add handicapped power operators at Main and Pool entries."|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2002"|"15"|"376,250"|"Replace galss block; ventilate stair towers; add windows in Band Room; provide shading and mirror glass in Cafeteria."|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"10"|"250,000"|"Repair and coat roof to reduce heat gain in building."|"1"|"PLASTIC"|"S"|"2002"|"10"|"0"||"1"|"COPPER"|"S"|"2002"|"20"|"65,000"|"Replace water filter / softener; add hose bibs at exterior roof doors."|"1"|"IRON"|"E"|"2002"|"50"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||"1"|"BOILERWATE"||"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"25"|"12,500"|"Revise exterior gas line to eliminate scrubbing of gas odor."|"1"|"S"|"2002"|"15"|"0"||"1"|"S"|"2002"|"15"|"172,500"|"Provide supply air for kiln ventilation; add unit for server/workroom; improve air transfer on Second Floor."|"1"|"S"|"2002"|"30"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"2002"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,INCANDESCE"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Stairs"|"0"|||"1"|"1"|"20,000"||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"0"|"0"|"0"|"0"|"1"|"1"|"KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,SCURITYSYS,LIGHTING"|"FULL"||"1"||"GOOD"|"Enlarge Kiln Room; add Kitchen equipment. $62,500"|"5,438,750"|"U"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"Paul R. Hedin, AIA"|"013571"|"I ACCEPT"|12/30/2010 4:56:26 PM| 819|"Johnstown City SD"|"17060001"|"Field House Concessions"|"0040"|"07/14/2010"|"1 Sir Bills Circle"|"Johnstown"|"12095-2030"|"ANNUAL"|"01/01/2011"|"2006"|"400"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Concession Stand"|"0"||"0"|"0"|"0"||||||"0"|"0"|"OTHER"|"Concessions"|"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2006"|"50"|"0"||"1"|"MUN_UTILIT"|"E"|"2006"|"50"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"E"|"2006"|"50"|"0"||"1"|"S"|"2006"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"20"|"0"||"1"|"ASPHALT"|"E"|"2006"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"30"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"2006"|"50"|"0"||"1"|"E"|"2006"|"50"|"0"||"1"|"E"|"2006"|"50"|"0"||"1"|"E"|"2006"|"50"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2006"|"50"|"0"||"1"|"S"|"2006"|"15"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"E"|"2006"|"50"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"2006"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"E"|"2006"|"50"|"0"||"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"1"|"2006"|"25"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2006"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"E"|"2006"|"20"|"0"||"1"|"IRON"|"E"|"2006"|"20"|"0"||"1"|"ELECTRIC"|"E"|"2006"|"10"|"0"||"1"|"E"|"2006"|"10"|"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2006"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"0"|"E"|"0"|"Bonacci Architects pllc"|"6320 Fly Road, East Syracuse, NY 13057"|"3154372636"|"studio@bonacci-architects.com"|"David J. Bonacci"|"015803"|"I ACCEPT"|12/31/2010 9:44:42 AM| 821|"West Canada Valley CSD"|"21030204"|"Junior-Senior High+Additions "|"0003"|"10/11/2010"|"5447 STATE RT 28 "|"NEWPORT "|" 13416"|"ANNUAL"|"11/01/2011"|"1963"|"156178"|"2"|"4"|"0"|"DISTRICT"|"INSTRUCT,DIST_ADMIN"||"746"|"Pre-K,K,1,2,3,4,5,6,7,8,9,10,11,12"|"0"|"0"|"1"|"746"|"0"|"1"|"OTHER"|"k-6 stage for OT/PT"|"50"|"59035"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,PREK,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"1"|"0"|"0"|"1"|"15000"|"S"|"2000"|"25"|"0"||"1"|"WELL"|"S"|"2000"|"15"|"0"||"1"|"SITESEPT"|"S"|"1988"|"15"|"0"||"1"|"E"|"1988"|"15"|"0"|"1000 buried tank for kitchen/boilers. 100 gal above ground tank for science/home careers"|"1"|"UTIL"|"BELOW"|"S"|"1988"|"40"|"45000"|"Additional light poles needed and upgrade existing."|"1"|"S"|"1988"|"25"|"0"||"0"||||"0"||"1"|"S"|"1988"|"10"|"0"|"Height adjustments and/or repair reconstruction need for CB's in main parking area in conjuction with repaving."|"0"||||"0"||"1"|"SURFACEH2O"||"1"|"S"|"1999"|"20"|"0"|"Storm outfall work in 1999"|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2008"|"5"|"584000"|"Front entry drive reconfigured, vistitor and bus garage area parking added in 2008. Main parking area deteriorated."|"1"|"CONCRETE"|"U"|"1988"|"5"|"144000"|"Elementary school entrance sidewalks in poor condition. Concrete walk to visitor parking added in 2008."|"1"|"S"|"1990"|"5"|"100000"|"Equpment in good condition but dated."|"1"|"U"|"2008"|"10"|"168000"|"N"|"New track resurfacing and soccer/football field crowning in 2008. Need dugouts replaced, new fencing and general reconstruction of playfields. Tennis court needs resurfacing."|"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"50"|"0"|"New classrom additions and health and wellness addition in 2008."|"1"|"S"|"1968"|"50"|"0"|"New classroom additions in 2008"|"1"|"S"|"1988"|"25"|"0"||"1"|"S"|"2010"|"5"|"287000"|"Remove and replace remaining black iron/splined ceilings in Jr/SR high to provide access and facilitate new light fixture placement, replace Elementary school tiles in corridors. "|"1"|"E"|"2008"|"15"|"0"|"Jr/SR high replaced in 2008"|"1"|"S"|"E"|"2010"|"15"|"0"|"Misc. interior doors replaced in 2008/2010. New hardware locksets/cylinders replaced in 2008"|"1"|"S"|"1988"|"50"|"0"||"1"|"S"|"1988"|"25"|"0"||"1"|"1"|"S"|"2010"|"25"|"0"|"Misc. electrical panel and distribution work performed in renovation/alteration ares in 2008/2010"|"1"|"S"|"2010"|"10"|"205000"|"Upgrade to energy efficient fixtures in elementary school, replace outdated ineffiecient lighting in HS classrooms, Band, cafeteria, tech rooms and increase light levels."|"1"|"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"1999"|"25"|"25000"|"Rebuilt sandfilters 2010, rebuilt pump 2010, Pool water heat exchanger rebuilt in 1984, replace or rebuild within the next 5 years"|"1"|"INSTRUCT,COMMON"|"S"|"1988"|"5"|"20000"|"Replace worn carpet in Elementary school corridors, elementary school classroom carpet still in satisfactory conditon but will need replacement within 5-10 years."|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"15"|"0"||"1"|"COMMON"|"S"|"2008"|"15"|"0"|"Terrazzo and Qt flooring in 2008 additions."|"1"|"COMMON"|"E"|"2010"|"25"|"0"|"HS gymnasium floor replaced in 2010, ES/MS gym floor reconditioned in 2010"|"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"50"|"0"|"New elemenatary school 1988. Classroom and Health Wellness additions in 2008."|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"Mortar repointing needed some locations"|"S"|"2010"|"25"|"10000"|"Gymnasium wall brick veneer repointed and reinforced in 2010. Misc. repointing needed on remaining original school. "|"1"|"MASONRY"|"E"|"2010"|"25"|"0"|"Chimney reconstructed in 2010"|"0"|||||"0"||"S"|"S"|"0"|"1"|"2010"|"15"|"0"|"Exterior entrance doors replaced at JR/HS 2010. New security upgrades to misc. exterior doors in 2008."|"1"|"S"|"1988"|"15"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"15"|"10000"|"JR/SR HS windows replaced in 2008. HS gymnasium windows replaced 2010. Elementary school windows showing condensation in insulated glass. "|"METONMET,OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2010"|"25"|"0"|"Roof replaced for entire facility in 2010."|"1"|"PLASTIC"|"E"|"2010"|"15"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"15"|"0"|"New water softener 2008"|"1"|"IRON,GALVANIZED,COPPER"|"S"|"1999"|"20"|"0"||"1"|"OIL"|"E"|"2008"|"15"|"0"|"1999 new HW storage tanks. 2008 summer boiler."|"1"|"S"|"1999"|"15"|"25000"|"new lavs and faucets, new flush toilets at JR SR HS misc. locations. ADA fixtures in locker rooms 2010. Replace elementary classroom sinks/DF with new."|"0"||"1"|"BOILERWATE"||"E"|"2008"|"20"|"0"|"New boilers in 2008"|"1"|"S"|"1999"|"25"|"0"||"1"|"E"|"2010"|"15"|"0"||"1"|"E"|"2010"|"15"|"0"|"JR/SR HS uv's and relief vents installed 2010."|"1"|"E"|"2010"|"25"|"0"|"New piping to UV replacement work in 2010. New piping to Classroom additions 2008."|"0"|"S"|"2010"||"0"||"1"|"S"|"2010"|"15"|"150000"|"Replace Elementary school controls installed in 1988."|"1"|"E"|"2010"|"15"|"0"||"1"|"E"|"2010"|"15"|"0"||"1"|"S"|"1988"|"1988"|"20000"|"Original ANSUL systems in kitchen hoods. Connect to new gas supply shutoffs."|"1"|"E"|"2010"|"15"|"80000"|"Provide new emergency lighting in Elementary school corridors connected to new emergency generator."|"1"|"E"|"2010"|"30"|"0"||"1"|"1"|"25000"|"Upgrade elementary school gang toilet fixtures and partitions."|"GOOD"||"GOOD"||"1"|"1"|"FAIR"||"FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"||"0"|"0"|"0"|"0"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"0"|"1"|"COMMSYS,KITCHEN,HVAC,COOKING,FIREALARM,FRIDGE,LIGHTING"|"FULL"|"1"|"1"||"FAIR"||"2373000"|"S"|"0"|"Glynn spillane griffing architects P.C."|"187 Wolf Road Suite 211 Albany N.Y. 12205"|"518 463 1114"|"rmichel@gsgarchitects.com"|"Richard Michel"|"022253"|"I ACCEPT"|12/31/2010 12:06:58 PM| 822|"Greenwich CSD"|"64080104"|"High School"|"0007"|"04/07/2010"|"GRAY AVE "|"GREENWICH "|" 12834"|"ANNUAL"|"01/01/2011"|"1964"|"93,443"|"2"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"510"|"7,8,9,10,11,12"|"0"|"1"|"0"|"510"|"0"|"0"|||"49"|"40,000"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,TECHSHOP"||"1"|"0"|"0"|"1"|"15,000"|"S"|"1999"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1964"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1999"|"20"|"0"||"1"|"S"|"1999"|"20"|"0"|"Propane for science rooms and boiler ignition."|"1"|"UTIL"|"BELOW"|"S"|"1999"|"3"|"180,900"|"Typically satisfactory (20) - install generator to support emergency shelter designation (3)."|"1"|"S"|"1999"|"20"|"0"||"0"||||"0"||"1"|"S"|"1999"|"15"|"12,400"|"Replace deteriorated catch basin and paving south of the auditorium (1)."|"1"|"S"|"1980"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"1"|"S"|"1980"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"2007"|"3"|"585,700"|"Bus loop, 2 parking lots and road next to tennis courts."|"1"|"CONCRETE,ASPHALT"|"S"|"2007"|"10"|"0"||"0"||||"0"||"1"|"U"|"2007"|"1"|"942,300"|"N"|"Track requires some reconstruction, resurfacing and drainage work (1). Resurface tennis courts, replace poles and lights, irrigate football field, add a general purpose field and reconstruct baseball field (3)."|"RECONCRETE"|"1"|"0"|"1"|"0"|"0"|"0"|"S"|"1999"|"20"|"0"|"Owner should repair and patch south foundation wall of auditorium and technology room then continue to monitor."|"1"|"S"|"1999"|"20"|"0"|"Minor cracking at stair towers noted, continue to monitor."|"1"|"S"|"2004"|"3"|"75,000"|"Typically satisfactory (15) - convert home economics to demonstration science room (3)."|"1"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"3"|"203,300"|"Lockers are satisfactory (15) - the BCS has no place for 735 deteriorated auditorium seats and stage curtains (3)."|"1"|"S"|"S"|"1999"|"15"|"0"||"1"|"S"|"1999"|"20"|"0"||"1"|"U"|"1999"|"1"|"23,300"|"Elevator is satisfactory (15) - portable handicap lift to stage required (1)."|"1"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"1999"|"3"|"18,800"|"Typically satisfactory (10) - replace stage lighting console (3)."|"1"|"1"|"S"|"1999"|"3"|"547,000"|"Typically satisfactory (10) - provide digital video projection system in auditorium, upgrade district wide telephone system and technology (3)."|"0"||||"0"||"1"|"INSTRUCT"|"U"|"1999"|"3"|"28,400"|"Media center."|"1"|"INSTRUCT,COMMON"|"S"|"2007"|"15"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1999"|"20"|"0"||"1"|"INSTRUCT"|"U"|"1999"|"1"|"64,900"|"Gym floor needs refinishing and replace CAD lab wood floor which has asbestos dampproofing under with infill and VCT."|"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"2007"|"20"|"0"|"Continue to monitor settlement at south corner of technology room."|"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"20"|"0"||"1"|"MASONRY"|"S"|"2005"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2007"|"3"|"40,800"|"Typically satisfactory (15) - replace main entrance and north H.C. entrance doors as part of security upgrades (3)."|"1"|"S"|"1999"|"20"|"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1999"|"15"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP,FORMMETAL,OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"1"||"U"|"1999"|"1"|"1,031,800"|"40%of EPDM rubber roofs over built-up asphalt and all SPF roofs over built-up asphalt are unsatisfactory. This is approximately 70% of the total roof area."|"1"|"PLASTIC"|"S"|"1999"|"15"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1999"|"20"|"0"||"1"|"IRON,COPPER"|"S"|"1999"|"20"|"0"||"1"|"OIL,ELECTRIC,OTHER"|"S"|"2005"|"10"|"0"|"2 oil, 1 electric and 1 instantaneous hot water heat exchanger."|"1"|"S"|"1999"|"20"|"0"||"0"||"0"|"BOILERWATE"||"S"|"1999"|"15"|"0"||"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"2005"|"10"|"0"||"1"|"S"|"1999"|"1"|"7,500"|"Typically satisfactory (15) - replace remaining original exhaust fans and gravity ventilators as part of roof replacement (1)."|"1"|"S"|"2007"|"10"|"0"||"1"|"S"|"1999"|"15"|"0"||"1"|"U"|"1999"|"1"|"293,700"|"Replace original pneumatic controls with DDC controls and integrate with campus wide energy management system."|"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"1999"|"10"|"0"||"1"|"S"|"2005"|"2005"|"0"||"1"|"U"|"2004"|"3"|"21,000"|"Exterior side of building exits, shops, labs and gang toilets outside assembly spaces require emergency lights per current code."|"0"||||"0"||"0"|"0"|"0"|"HC lift to stage is required and is included in BCS no. 51. Automatic door operation at main and back HC entrances is included in BCS no. 64."|"GOOD"||"GOOD"||"0"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"1"|"1"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"||"1"|"1"|"0"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"0"||"FULL"||"1"|"0"|"GOOD"||"4,076,800"|"U"|"1"|"St. John Architects"|"172 Ridge Street, Glens Falls, NY 12801"|"518-223-0225"|"sjarch@roadrunner.com"|"Samuel D. St. John"|"019740"|"I ACCEPT"|12/31/2010 12:54:57 PM| 824|"Yonkers City SD"|"66230001"|"FOXFIRE SCHOOL"|"0302"|"09/02/2010"|"1061 NO BROADWAY "|"YONKERS "|" 10703"|"ANNUAL"|"08/01/2011"|"1955"|"86000"|"3"|"4"|"0"|"DISTRICT"|"INSTRUCT"||"450"|"Pre-K,K,1,2,3,4,5,6"|"0"|"1"|"1"|"450"|"0"|"0"|||"19"|"14890"|"ADMIN,ART,AUDITORIUM,CAFE,GYM,KITCHEN,LIBBRARY,MUSIC,PREK,REMEDIAL,RSRCEROOM,SPECED"||"1"|"1"|"5000"|"0"|"0"|"S"|"1955"|"7"|"0"||"1"|"MUN_UTILIT"|"S"|"1955"|"3"|"30000"|"Add RPZ backflow preventer on water service"|"1"|"MUN_UTILIT"|"S"|"1955"|"7"|"0"||"1"|"S"|"1955"|"7"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1955"|"10"|"0"||"1"|"S"|"1955"|"15"|"0"||"0"||||"0"||"1"|"S"|"1955"|"7"|"500"|"Clean out catch basin at exterior south"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"10"|"15000"|"Demolish failing canopy at north side of bldg near play area"|"1"|"CONCRETE,ASPHALT"|"S"|"1955"|"7"|"59000"|"Replace walkway by play area heaved by roots Clean cracks of grass Pave 18in grass swath disrupting asphalt path behind aud Repair cracks at aud ramp Repair spalling at flag pole plaza Replace spalled areas at concrete ramp near 2nd floor main entry"|"1"|"S"|"1998"|"7"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1955"|"15"|"0"||"1"|"S"|"1955"|"3"|"3500"|"Provide stainless steel corner guards at corridor 2 Provide fusible link dampers on louvers to kitchen"|"1"|"S"|"2010"|"7"|"518050"|"Add wihte boards in sev classrms Replace casework in sev classrms Replace servery counter Renovate abandoned radio station into two classrms Replace aud seating and curtains"|"1"|"U"|"1990"|"0"|"439875"|"Most classrooms corridors cafeteria and library need new ceilings Lighting upgrade should be done at same time"|"0"||||"0"||"1"|"U"|"U"|"1955"|"0"|"54800"|"Many closers and smoke door issues Allowance to upgrade to ADA lever hardware"|"1"|"S"|"1955"|"10"|"0"||"0"||||"0"||"1"|"0"|"U"|"1955"|"0"|"395000"|"Replace main distribution board and panel boards that are exceeded on capacity Receptacles needed in classrooms"|"1"|"S"|"1996"|"3"|"262465"|"Add one exterior light over Aud exit door Repair several ballasts Replace Aud and stage lighting which are inadequate"|"1"|"0"|"U"|"1955"|"0"|"240000"|"No PA system in aud Speakers and bells past useful life Clocks past useful life No sound system in gym"|"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"7"|"1000"|"Secure loose carpet tile in Cl 112 and rubber base there and in Cl 109"|"1"|"INSTRUCT,COMMON"|"S"|"2010"|"10"|"72514"|"Some spaces not satisfactory Corr 2 Cl 218 Fac Lounge 212 and Aud Some spaces need abatement plus new VCT"|"1"|"COMMON"|"S"|"1955"|"7"|"2500"|"Patching of select areas"|"1"|"COMMON"|"S"|"1955"|"15"|"0"||"SLABGRADE,OTHER"|"concrete beams"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1955"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"0"|"0"|"0"||"S"|"2008"|"7"|"34000"|"Repair waterproofing at elec vault Repoint stone wall near play area and along stair from Aud platform to 2nd flr entry Repair concrete braces at chimney tower Reset large stone cap at ext S wall Replace loos louvers S facade soffit"|"1"|"MASONRY"|"S"|"1955"|"7"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1955"|"2"|"20000"|"Replace select doors as noted West end corridor 1-2 Upper lobby to ccourtyrad Vestibule 2nd level stair 3"|"1"|"S"|"1955"|"3"|"37080"|"At guard rail at retaining wall NW side and handrail at 2nd level villa stair Replace chipped treads at courtyard near play area Repair wall and add handrail at stair from Aud and upper lot"|"0"|||||"0"||"1"|"ALUMINUM,STEEL"|"U"|"Y"|"2009"|"0"|"704900"|"Replace balance of original windows Priority given to classrooms without rescue windows"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"20"|"31500"|"Preventative maintenance and film on skylights"|"1"|"PLASTIC"|"S"|"2008"|"20"|"0"|"Included in roofing costs above"|"1"|"COPPER"|"S"|"1955"|"3"|"35000"|"Add backflow preventer and metering faucets"|"1"|"IRON"|"S"|"1955"|"5"|"5000"|"Add grease trap on kitchen pot sink"|"1"|"NAT_GAS"|"S"|"2008"|"7"|"0"||"1"|"S"|"1955"|"7"|"16200"|"Faucet leaking One drain assembly failed Need vacuum breakers on slop sinks and Replace 16 rusted toilet stalls"|"0"||"1"|"BOILERSTEA"||"E"|"2008"|"15"|"0"||"1"|"S"|"1955"|"7"|"0"||"1"|"S"|"1990"|"7"|"0"||"1"|"U"|"1955"|"0"|"890000"|"Cafeteria and several classrms have no mech ventilation as required Unit ventilators in balance of bldg are past useful life Add exhaust to custodial closets"|"1"|"S"|"1955"|"10"|"0"||"1"|"S"|"1955"|"10"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"U"|"1990"|"0"|"180000"|"Replace system due to age"|"0"||||"0"||"1"|"S"|"1995"|"1995"|"0"|"Kitchen stove hood"|"1"|"S"|"2008"|"8"|"0"||"0"||||"0"||"1"|"0"|"400000"|"Elevator and several lifts needed"|"FAIR"||"GOOD"||"0"|"1"|"FAIR"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"1"|"CLASSROOMS,OTHER"||"1"|"CLASSROOMS,OTHER"||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"1"|"1"|"0"|"1"|"0"|"0"|"POOR"|"0"|"FAIR"||"0"|"1"|"0"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"||"FULL"||"1"||"FAIR"||"4409884"|"U"|"1"|"KGD Architects PC"|"285 Main Street Mount Kisco NY 10549"|"9146665900"|"rdavidson@kgdarchitects.com"|"Russell A Davidson AIA"|"019885"|"I ACCEPT"|1/1/2011 11:27:18 AM| 829|"Auburn City SD"|"05010001"|"Casey Park Elementary School"|"0012"|"04/07/2010"|"101 Pulaski Street"|"Auburn"|" 13021"|"ANNUAL"|"10/01/2010"|"1963"|"76070"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"414"|"K,1,2,3,4,5"|"0"|"1"|"1"|"414"|"0"|"0"|||"33"|"28698"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,SPECED"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"1963"|"15"|"0"||"1"|"S"|"1963"|"15"|"0"||"1"|"UTIL"|"BELOW"|"E"|"1998"|"40"|"0"||"1"|"S"|"1963"|"15"|"0"||"0"||||"0"||"1"|"U"|"1963"|"15"|"7500"|"several catch basins should be raised / leveled"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1963"|"10"|"5000 "|"spot areas of asphalt needed"|"1"|"CONCRETE"|"S"|"1963"|"15"|"0"||"1"|"S"|"1994"|"15"|"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1994"|"40"|"5000"|"Concrete foundation / retaining walls in poor condition at ramp to basement"|"1"|"S"|"1994"|"20"|"1000"|"south gymnasium wall has moderate cracking"|"1"|"S"|"1994"|"20"|"0"||"1"|"S"|"1994"|"10"|"24000"|"skylights are concealed above ceilings , re-establish soffits to skylights"|"1"|"S"|"1963"|"10"|"0"||"1"|"U"|"U"|"1994"|"10"|"180000"|"replace original classroom doors, non-compliant louvers, non-compliant ADA compliant hardware"|"1"|"S"|"1963"|"30"|"18000"|"build rated storage enclosures"|"1"|"S"|"1997"|"15"|"0"|"2 elevators in building, one is 20+ years old"|"1"|"1"|"S"|"2001"|"30"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"1"|"E"|"2010"|"5"|"27000"|"replace clock system"|"0"||||"0"||"1"|"COMMON"|"U"|"1997"|"3"|"43000"|"Carpet worn in corridor of north classroom wing - replace"|"1"|"INSTRUCT,COMMON"|"U"|"1963"|"3"|"166000"|"Replace VAT in auditorium and 1963 classrooms; repair sheet vinyl welds in cafeteria"|"1"|"COMMON"|"U"|"1963"|"10"|"59000"|"tile finishes are worn and dated; replace toilet room finishes in 1963 wing"|"1"|"INSTRUCT,COMMON"|"U"|"1963"|"7"|"10000"|"Refinish wood stage floor"|"SLABGRADE,CONCRMETAL,OTHER"|"reinforced concrete beams, beams and columns"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1997"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1997"|"20"|"8300"|"exterior machine room exterior brick is spalling badly"|"0"|||||"0"||"0"|||||"0"||"E"|"E"|"0"|"0"|"2004"|"15"|"24000"|"security lock to Main Office desired"|"1"|"S"|"1997"|"15"|"28500"|"Major efflorescence on loading dock retaining wall; north parking lot retaining wall needs to be repaired"|"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"2003"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"1"|"PLASTIC"|"S"|"2003"|"10"|"0"||"1"|"GALVANIZED,COPPER"|"S"|"1999"|"50"|"17500"|"replace remaining galvanized piping"|"1"|"IRON"|"S"|"1999"|"90"|"20000"|"replace mains in 1963 wing"|"1"|"NAT_GAS"|"S"|"1998"|"10"|"0"||"1"|"S"|"1999"|"5"|"70000"|"replace tank type toilets; replace fixtures in 1963 wing; replace manual flush valves and faucets with battery power automatic valves"|"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"2007"|"18"|"0"||"1"|"S"|"1999"|"18"|"0"||"1"|"E"|"2007"|"13"|"0"||"1"|"S"|"1998"|"18"|"0"||"1"|"S"|"2007"|"28"|"0"||"1"|"S"|"1998"|"28"|"0"||"1"|"E"|"2010"|"15"|"103000"|"replace remaining pneumatic DDC control system with electronic DDC. Provide an allowance for this work"|"1"|"E"|"2009"|"20"|"0"|"no strobes in classrooms"|"1"|"E"|"2009"|"20"|"0"||"0"||||"0"||"1"|"E"|"2009"|"15"|"0"||"1"|"S"|"1999"|"20"|"0"|"one automatic transfer switch; no remote stop"|"1"|"1"|"105000"|"ADA toilet rooms in 11, 13, 15 and 17 ; lever door hardware in 1963 and 1985 wings"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"0"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"1"|"1"|"1"|"COMMSYS,FIREALARM,LIGHTING"|"WARMING"|"0"|"1"||"GOOD"||"975000"|"S"|"1"|"SWBR Architects"|"387 East Main Street, Suite 500, Rochester, NY 14604"|"585-232-8300"|"rmccormick@swbr.com"|"Phillip W. Wise"|"016550"|"I accept"|1/1/2011 8:40:33 PM| 833|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"Building #10 - Filing Room"|"2054"|"05/11/2010"|"RD 2"|"Painted Post, NY"|"14870"|"ANNUAL"|"08/01/2011"|"1970"|"1197"|"1"|"2"|"1"|"DISTRICT"|"DIST_ADMIN"||"0"|||"0"|"1"||||||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"WELL"|"S"|"1970"|"20"|"0"||"1"|"SITESEPT"|"S"|"2003"|"15"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1975"|"15"|"0"||"0"||||"0"||"1"|"S"|"1970"|"20"|"0"||"1"|"S"|"1970"|"20"|"0"||"1"|"S"|"1970"|"20"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2005"|"2"|"0"|"New slurry seal is needed. "|"1"|"CONCRETE"|"S"|"2005"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1994"|"15"|"0"||"0"||||"0"||"1"|"S"|"1994"|"15"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"1994"|"10"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1975"|"5"|"2,500"|"Replace outdated panels. "|"1"|"S"|"1970"|"5"|"2,000"|"Replace building lighting."|"1"|"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1970"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST,OTHER"|"Steel girders, wood framing"|"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"S"|"1976"|"10"|"0"|"Steel girders have signs of corrosion."|"WOOD"|"0"|"0"||"0"|"0"|"0"|"0"|"1"||"S"|"1976"|"15"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"0"|"1994"|"10"|"0"||"1"|"S"|"2005"|"30"|"0"||"0"|||||"0"||"1"|"VINYL"|"S"|"NA"|"1994"|"10"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1994"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1994"|"15"|"0"||"1"|"PVC"|"S"|"1994"|"15"|"0"||"1"|"ELECTRIC"|"S"|"1994"|"4"|"3,000"|"Not ASME, provide tank-less gas water heater."|"1"|"S"|"1994"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2000"|"15"|"0"||"1"|"S"|"1994"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2000"|"15"|"0"||"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"S"|"2008"|"10"|"0"||"0"||||"0"||"1"|"1"|"5,000"|"Upgrade toilet room. "|"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"1"|"0"|||"0"|"0"|"0"|"GOOD"||"$3,000"|"S"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|1/3/2011 8:23:55 AM| 834|"Wyoming CSD"|"67100204"|"Bus Barn"|"0002"|"11/01/2010"|"Rt 19"|"Wyoming"|" 14591"|"ANNUAL"|"10/01/2011"|"2008"|"8,000"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"WELL"|"S"|"2008"|"20"|"0"||"1"|"SITESEPT"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2008"|"30"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2008"|"30"|"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2008"|"20"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"30"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"25"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2008"|"30"|"7,500"|"Replace corroded panel."|"1"|"S"|"2008"|"20"|"0"||"1"|"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2008"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2008"|"30"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"20"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2008"|"30"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2008"|"25"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2008"|"25"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"2008"|"40"|"0"||"1"|"NAT_GAS"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"35"|"0"||"1"|"CV"|"1"|"FURNACE"||"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"25"|"30,000"|"Add exhaust to Storage Room; provide outside air ducts to radient heat."|"0"||||"0"|"N/A"|"1"|"S"|"2008"|"30"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"20"|"0"||"0"||||"0"|"N/A"|"1"|"E"|"2008"|"20"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"37,500"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|1/3/2011 8:25:50 AM| 835|"Williamsville CSD"|"14020306"|"Dodge Elementary"|"0002"|"07/29/2010"|"1900 DODGE ROAD "|"E AMHERST "|" 14051"|"ANNUAL"|"07/01/2011"|"1953"|"91035"|"2"|"3"|"5"|"DISTRICT"|"INSTRUCT"||"624"|"K,1,2,3,4"|"0"|"1"|"0"|"624"|"0"|"0"|||"35"|"33600"|"ADMIN,ART,AUDITORIUM,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SPECED,TEACHRSRC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"5"|"0"||"1"|"MUN_UTILIT"|"S"|"1953"|"5"|"0"||"1"|"S"|"1985"|"20"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2010"|"20+"|"0"||"1"|"S"|"1953"|"10"|"0"||"1"|"S"|"1953"|"10"|"0"||"1"|"U"|"1953"|"10"|"6500"||"1"|"S"|"1952"|"10"|"0"||"0"|"MUNI"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2000"|"10"|"0"||"1"|"CONCRETE"|"S"|"2000"|"5"|"0"||"1"|"S"|"1998"|"5"|"0"||"1"|"S"|"2004"|"10"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1992"|"20"|"0"||"1"|"S"|"1992"|"20"|"0"||"1"|"S"|"1992"|"19"|"0"||"1"|"S"|"2001"|"16"|"0"||"1"|"S"|"1992"|"18"|"0"||"1"|"S"|"S"|"2001"|"19"|"0"||"1"|"S"|"1953"|"20"|"0"||"1"|"E"|"1992"|"15"|"0"||"1"|"1"|"S"|"2010"|"20+"|"0"||"1"|"E"|"2009"|"20+"|"0"||"1"|"1"|"S"|"2010"|"20+"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2000"|"14"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"16"|"0"||"1"|"COMMON"|"S"|"2010"|"19"|"0"||"1"|"COMMON"|"S"|"1953"|"15"|"0"||"SLABGRADE,CONCRMETAL,OTHER"|"2 way concrete slab"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1992"|"20"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"0"|"1"|"0"|"1"||"S"|"1992"|"20"|"0"||"1"|"MASONRY"|"S"|"1953"|"5"|"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1992"|"14"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"10"|"0"||"METONMET"|"SINGLEPLY,BUILTUP,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"1"|"0"|"areas of standing water under IRMA panels"|"S"|"1992"|"7"|"0"||"1"|"PLASTIC"|"S"|"1992"|"7"|"0"||"1"|"COPPER"|"S"|"1992"|"20"|"0"||"1"|"IRON"|"S"|"1953"|"5"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"||"1"|"S"|"1990"|"20"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"Unit ventilation"|"E"|"2008"|"20+"|"0"||"1"|"E"|"2008"|"20+"|"0"||"1"|"S"|"2006"|"14"|"0"||"1"|"S"|"2006"|"10"|"0"||"1"|"S"|"1952"|"5"|"0"||"1"|"S"|"1952"|"5"|"0"||"1"|"S"|"2008"|"15"|"0"||"1"|"S"|"2007"|"20+"|"0"||"1"|"S"|"2007"|"20+"|"0"||"1"|"S"|"1953"|"1953"|"0"||"1"|"S"|"1985"|"5"|"0"||"1"|"S"|"2006"|"20+"|"0"||"1"|"1"||"Work scheduled for 2011"|"GOOD"||"GOOD"||"0"|"1"|"GOOD"|"Echoing in the auditorium"|"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"1"|"CLASSROOMS,HALLWAYS"||"0"|||"1"|"1"||"Some ceiling tiles have water stains"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"GOOD"|"Building staff notes that filters are changed approximately 3 times per year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"WARMING"||"0"|"1"|"GOOD"||"6500"|"S"|"1"|"Kideney Architects PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|1/3/2011 9:04:43 AM| 836|"Warsaw CSD"|"67150104"|"Bus Garage"|"5014"|"05/25/2010"|"Court Street"|"Warsaw"|"14569"|"ANNUAL"|"08/01/2011"|"2003"|"1198"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Storage of busses"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"||"1"|"MUN_UTILIT"|"S"|"2003"|"30"|"0"||"0"||||"0"||"1"|"UTIL"|"BELOW"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"30"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"1"|"SURFACEH2O"||"1"|"S"|"2004"|"15"|"0"||"1"|"S"|"2004"|"15"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"ASPHALT"|"S"|"2003"|"10"|"0"||"1"|"ASPHALT"|"S"|"2003"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2003"|"30"|"0"||"1"|"S"|"2003"|"25"|"0"||"0"|"S"|"2003"|"25"|"1,250"|"Paint bathrooms."|"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"S"|"S"|"2003"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"1"|"S"|"2003"|"8"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2003"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2003"|"30"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"30"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"OTHER"|"S"|"NA"|"2003"|"15"|"0"||"WOODONWOOD"|"ASPHALT"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2003"|"15"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2003"|"20"|"0"||"1"|"IRON"|"S"|"2003"|"25"|"0"||"1"|"ELECTRIC"|"S"|"2003"|"8"|"0"||"1"|"S"|"2003"|"20"|"0"||"0"||"1"|"OTHER"||"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"10"|"0"||"0"||||"0"||"1"|"S"|"2003"|"2"|"7,500"|"Install ventilation."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2003"|"15"|"0"||"0"||||"0"||"1"|"S"|"2003"|"10"|"0"||"0"|"S"|||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"|"SPOT"|"0"|"1"|"1"|"0"|"1"|"0"|"0"||||"1"||"GOOD"||"11,250"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"Robert J. Nordin, AIA, LEED AP"|"028213"|"I ACCEPT"|1/3/2011 9:12:55 AM| 839|"BOCES Schuyler-Chemung-Tioga"|"55900000"|"Building #13 - Gas House"|"7016"|"05/11/2010"|"RD 2"|"Painted Post"|"14870"|"ANNUAL"|"08/01/2011"|"1968"|"200"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Gas meter house"|"0"|||"0"|"0"||||||"0"|"0"|"OTHER"|"Gas House"|"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"GRAVEL"|"S"|"1968"|"5"|"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"1"|"S"|"1968"|"10"|"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1968"|"20"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"1968"|"20"|"0"||"U"|"U"|"0"|"0"|"1968"|"1"|"2,000"||"0"||||"0"||"0"|||||"0"||"0"||||||"0"||"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"||"U"|"1968"|"1"|"8,000"|"Roof to be replaced in 2011 Project."|"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|"0"|"0"||"FAIR"||"FAIR"||"0"|"0"|"FAIR"||"INCANDESCE"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"1"||"1"|"1"|"1"|"1"|"0"||"0"|"1"|"1"|"0"|"1"|"0"|"0"|||"0"|"0"|"0"|"FAIR"||"$10,000"|"U"|"0"|"Beardsley Design Associates"|"64 South Street, Auburn, NY 13021"|"315-253-7301"|"bda@beardsley.com"|"Richard C. Elliott, P.E."|"076285"|"I ACCEPT"|1/3/2011 9:41:12 AM| 840|"Cleveland Hill UFSD"|"14070302"|"Maintenance"|"3009"|"04/01/2010"|"105 Mapleview Drive"|"Cheektowaga"|" 14225"|"ANNUAL"|"12/01/2010"|"1953"|"980"|"1"|"0"|"0"|"DISTRICT"|"OTHER"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"0"||||||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"1"|"SELF"|"ABOVE"|"S"|"1990"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||"1"|"S"|||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"15"|"0"||"1"|"CONCRETE"|"S"|"2001"|"15"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1953"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1953"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"1990"|"10"|"0"||"1"|"S"|"1990"|"5"|"0"||"0"|||||"0"||"0"||||"0"||"0"|||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1953"|"7"|"0"|"Oil stains on floor"|"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1953"|"15"|"0"|"Minor cracking but no signs of structural concerns"|"MASONRY"|"0"|"1"||"1"|"0"|"0"|"0"|"0"||"S"|"1953"|"15"|"0"|"Some rust at bottom of columns"|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2008"|"10"|"0"|"Overhead door - some minor dents"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"U"|"NA"|"1953"|"3"|"2,211.75"|"Frames are rusty, caulk failing"|"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2009"|"20"|"0"|"Bottom decking flute rusting, sings of roof leak, west wall due to hole cut in roof deck"|"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"0"||||"0"||"0"||"0"||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"S"|"1953"|"7"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"0"|"0"|"N/A - Maintenance garage"|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"FAIR"||"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Roof"|"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"1"|"FAIR"|"Only ventilation is small operable windows. Exhaust smell within building"|"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"|||"0"|"0"|"0"|||"0"|"0"|"0"|"FAIR"||"$2,211.75"|"S"|"0"|"Young + Wright Architectural"|"740 Seneca Street"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|1/3/2011 9:51:24 AM| 842|"Rochester City SD"|"26160001"|"Adlai Stevenson School #29"|"0029"|"08/10/2010"|"88 KIRKLAND ROAD "|"ROCHESTER "|" 14611"|"ANNUAL"|"08/01/2009"|"1964"|"98162"|"2"|"4"|"1"|"DISTRICT"|"INSTRUCT"||"381"|"K,1,2,3,4,5,6"|"0"|"1"|"0"|"381"|"0"|"0"|||"41"|"30986"|"AUDITORIUM,CAFE,COMPROOM,GYM,KITCHEN,LIBBRARY,MUSIC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1995"|"25"|"0"|"RPZ installed in 1995"|"1"|"MUN_UTILIT"|"S"|"1965"|"15"|"0"||"1"|"S"|"1965"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1992"|"5"|"0"|"new secondary connection to main distribution parel"|"1"|"S"|"1993"|"25"|"0"||"0"||||"0"||"1"|"S"|"1993"|"25"|"650"|"replace manhole cover"|"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1993"|"5"|"236600"|"full depth reconstruction of pavement areas/ bollard replacement at courtyard parking lot"|"1"|"CONCRETE"|"S"|"1993"|"5"|"93795"|"replace sidewalk sections/cover hole in grass by kenwood ave."|"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2006"|"20"|"0"|"N"|"rence replacement at 4', 8', 12' heights"|"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1964"|"50"|"0"||"1"|"S"|"1964"|"50"|"0"||"1"|"S"|"2003"|"20"|"0"|"patch and repair CMU cracks at various locations"|"1"|"S"|"2003"|"10"|"0"|"replace cafeteria and physical therapy ceilings"|"1"|"S"|"1991"|"5"|"35000"|"reokace damages and wornout casework in classrooms"|"1"|"S"|"S"|"2006"|"2"|"228900"|"replace various wornout doors and add closers to classroom doors"|"1"|"S"|"1964"|"50"|"0"||"1"|"S"|"1964"|"40"|"0"||"1"|"1"|"S"|"1992"|"10"|"0"|"replace (4) existing federal pacific panelboards"|"1"|"S"|"2003"|"15"|"0"||"1"|"1"|"S"|"2009"|"10"|"0"|"IP Phone syste, added for admin phones only"|"0"||||"0"||"0"|"INSTRUCT"|"S"|"1991"|"10"|"0"|"replace kindergarten wing carpeting and library carpeting"|"1"|"INSTRUCT,COMMON"|"S"|"1991"|"10"|"43800"|"replace VAT in classrooms (approx. 12000 SF)"|"1"|"COMMON"|"S"|"1991"|"20"|"0"||"1"|"COMMON"|"S"|"1991"|"20"|"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1964"|"50"|"0"||"CONCRETE,MASONRY"|"0"|"1"||"0"|"0"|"0"|"1"|"0"||"S"|"1964"|"35"|"0"|"repair required for approx. 50 SF of concrete beams and columns"|"1"|"MASONRY"|"S"|"1964"|"50"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2003"|"15"|"0"|"Exit #17 double doors need to be replaced"|"1"|"S"|"2003"|"20"|"0"|"replace handrail"|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2003"|"5"|"314000"|"replace insulated metal panels and clerestory windows"|"OTHER"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1999"|"10"|"0"|"visual insp. only"|"1"|"PLASTIC"|"S"|"1999"|"2"|"0"|"replace skylight"|"1"|"IRON,COPPER"|"S"|"1995"|"15"|"0"|"booster pump system and RPZ installed in 1995"|"1"|"IRON,COPPER"|"S"|"1990"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2004"|"9"|"0"||"1"|"S"|"1964"|"5"|"32000"|"classroom sinks and lavatories are in satisfactory condition but faucets are in need of replacement. Classroom bubblers are generally bot used due to their poor condition"|"0"||"1"|"BOILERSTEA,OTHER"|"unit ventilation"|"S"|"1965"|"3"|"0"|"boilers and pump sets"|"1"|"S"|"1965"|"10"|"0"|"replace with boilers"|"1"|"S"|"1997"|"10"|"0"|"replace misc. split system condensing units"|"1"|"S"|"1965"|"5"|"0"|"(3) indoor AHU's, (1) rooftop AHU unit vents, vapor barrier in crawl space."|"1"|"S"|"1965"|"10"|"0"|"replace with boilers, replace CUH's"|"1"|"S"|"1965"|"10"|"0"|"replace with AHU's"|"1"|"S"|"2003"|"10"|"0"|"upgrade with boiler"|"1"|"S"|"1991"|"5"|"0"|"complete system replacement with new point addressable system "|"1"|"S"|"1991"|"5"|"0"|"replace detectors with addressable type and add new for code compliance"|"1"|"S"|"1991"|"1991"|"10000"|"add ansyl system over range in kitchen"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2003"|"15"|"0"|"boilers, lighting, fire alarm, communications on generator"|"1"|"1"||"provide HC striping and signage"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"1873265"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|1/3/2011 10:00:48 AM| 843|"BOCES Genesee Valley (Gen-Liv-Steu-)"|"24900000"|"EAP-PALACE OFFICE BUILDING "|"1011"|"09/08/2010"|"61 MAIN ST "|"GENESEO "|" 14454"|"ANNUAL"|"08/01/2011"|"1940"|"8244"|"1"|"0"|"0"|"LSD_DIST"|"DIST_ADMIN,OTHER"|"EAP Office, Healthcare Office"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1940"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"1940"|"10"|"0"||"0"||||"0"||"1"|"UTIL"|"ABOVE"|"S"|"1980"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||"0"|"N/A"|"0"|||||"0"|"N/A"|"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"1"|"0"|"0"|"0"|"S"|"1940"|"30"|"$10,000"|"Repair"|"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"20"|"0"||"1"|"S"|"1995"|"15"|"0"||"0"||||"0"|"N/A"|"1"|"S"|"S"|"1995"|"15"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"2000"|"5"|"0"||"0"|||||"0"||"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1940"|"25"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1940"|"30"|"0"||"0"|||||"0"||"1"|"MASONRY"|"S"|"1940"|"25"|"0"||"S"|"S"|"0"|"1"|"1995"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM,VINYL"|"S"|"NA"|"1995"|"25"|"0"||"WOODONWOOD"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1995"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON,PVC"|"S"|"2002"|"15"|"0"||"1"|"ELECTRIC"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"15"|"0"||"0"||"1"|"OTHER"||"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"2006"|"15"|"0"||"1"|"S"|"2006"|"15"|"0"||"0"||||"0"||"1"|"S"|"2002"|"10"|"0"||"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"0"|"S"|"1"|"Habiterra Architecture and Landscape Architecture P.C."|"1279 North Main Street, Jamestown, New York, 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter"|"0232261"|"I ACCEPT"|1/3/2011 10:01:19 AM| 844|"Williamsville CSD"|"14020306"|"Country Parkway Elementary"|"0011"|"07/15/2010"|"35 HOLLYBROOK "|"WILLIAMSVILLE "|" 14221"|"ANNUAL"|"07/01/2011"|"1968"|"74655"|"1"|"4"|"2"|"DISTRICT"|"INSTRUCT"||"612"|"K,1,2,3,4"|"0"|"1"|"0"|"612"|"0"|"0"|||"40"|"28800"|"ART,CAFE,COMPROOM,GYM,HLTHSUITE,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC,REMEDIAL"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"E"|"2010"|"20+"|"0"|"water main from street and backflow preventer scheduled for replacement in 2011/2012 noted as 2010"|"1"|"MUN_UTILIT"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2010"|"20+"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"2010"|"10"|"0"||"1"|"S"|"1968"|"5"|"0"||"0"||||"0"||"0"|"MUNI"||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"U"|"1999"|"0"|"365560"|"work may go into 2011 project"|"1"|"CONCRETE"|"S"|"2004"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"|"N"||"RECONCRETE"|"1"|"0"|"0"|"0"|"0"|"0"|"S"|"1968"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"1991"|"20"|"0"||"1"|"S"|"2001"|"16"|"0"||"1"|"S"|"1967"|"20"|"0"||"1"|"S"|"S"|"1991"|"18"|"0"||"1"|"S"|"1968"|"20"|"0"|"access/egress to fan room"|"0"||||"0"||"1"|"1"|"S"|"2010"|"20+"|"0"|"panelboard scheduled for replacement in 2011/2012 noted as 2010"|"1"|"S"|"2004"|"18"|"0"||"1"|"1"|"S"|"2010"|"10"|"0"||"0"||||"0"||"1"|"INSTRUCT,COMMON"|"S"|"2001"|"12"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1991"|"12"|"0"||"1"|"COMMON"|"S"|"1991"|"19"|"0"||"1"|"COMMON"|"S"|"1968"|"20"|"0"||"SLABGRADE,OTHER"|"concrete on steel beams"|"0"|"0"|"0"|"1"|"0"||"0"|"0"|"0"|"S"|"1991"|"20"|"0"||"MASONRY,OTHER"|"0"|"0"||"1"|"1"|"1"|"1"|"0"||"S"|"1992"|"19"|"0"||"1"|"MASONRY"|"S"|"1968"|"5"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2009"|"18"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"1992"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY,BUILTUP,IRMA"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"1"|"0"|"0"|"0"|"0"|"all roofs have extensive vegetation growth"|"S"|"1992"|"10"|"0"||"1"|"PLASTIC"|"S"|"1992"|"10"|"0"||"1"|"COPPER"|"S"|"2009"|"20"|"0"||"1"|"IRON"|"S"|"1968"|"10"|"0"||"1"|"NAT_GAS"|"E"|"2009"|"20"|"0"||"1"|"S"|"1999"|"10"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"E"|"2009"|"20+"|"0"||"1"|"E"|"2007"|"20+"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"2009"|"12"|"0"||"1"|"S"|"2009"|"10"|"0"||"1"|"S"|"1968"|"10"|"0"||"1"|"E"|"2010"|"20+"|"0"|"scheduled for replacement in 2011/2012 noted as 2010"|"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"2009"|"20+"|"0"||"1"|"S"|"1968"|"1968"|"0"||"1"|"S"|"1968"|"5"|"0"||"1"|"S"|"2007"|"20+"|"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"1"|"CLASSROOMS,HALLWAYS,OTHER"|"assembly, other"|"1"|"CLASSROOMS"||"1"|"1"||"some ceiling tiles have water stains"|"0"|"0"|"0"|"0"|"1"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"building staff noted that filters are changed approximately 3 times per year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"365560"|"S"|"1"|"Kideney Architects, PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|1/3/2011 10:06:42 AM| 845|"Gowanda CSD"|"04280106"|"Bus Garage"|"5004"|"09/15/2010"|"Panther Drive"|"Gowanda"|" 14070"|"ANNUAL"|"07/01/2011"|"2002"|"14,400"|"1"|"0"|"0"|"DISTRICT"|"OTHER"|"Bus Maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|||"1"|"2"|"5000"|"0"|"0"|"S"|"1997"|"10"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"15"|"0"||"1"|"UTIL"|"ABOVE"|"S"|"2002"|"5"|"6,000"|"Add site lighting."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"10"|"50,000"|"Expand parking area."|"1"|"CONCRETE"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2002"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2002"|"5"|"6,000"|"Upgrade devices."|"1"|"S"|"2002"|"3"|"45,000"|"Replace T-12 fixtures."|"1"|"1"|"S"|"2002"|"15"|"15,000"|"Replace telephone system."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"2002"|"10"|"0"||"1"|"COMMON"|"S"|"2002"|"30"|"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"2002"|"25"|"0"||"MASONRY,STEEL"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2002"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"S"|"NA"|"2002"|"20"|"0"||"METONMET"|"FORMMETAL"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"2002"|"20"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"2002"|"15"|"0"||"1"|"IRON,COPPER,PVC"|"S"|"2002"|"15"|"0"||"1"|"NAT_GAS"|"S"|"2002"|"10"|"0"||"1"|"S"|"2002"|"20"|"0"||"0"||"1"|"FURNACE"||"S"|"2002"|"5"|"6,000"|"Replace unite heater."|"1"|"S"|"2002"|"8"|"0"||"0"|"S"|"2009"|"15"|"0"||"1"|"S"|"2005"|"5"|"115,000"|"Add makeup ventilation air and exhaust fans at Bus Storage."|"0"||||"0"||"1"|"S"|"2009"|"15"|"0"||"1"|"S"|"2002"|"5"|"30,000"|"Add CO sensors."|"1"|"S"|"2002"|"5"|"12,000"|"Upgrade system."|"1"|"S"|"2002"|"2"|"5,000"|"Upgrade system."|"0"||||"0"||"1"|"S"|"2002"|"3"|"20,000"|"Upgrade system."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"GOOD"|"1"|"GOOD"||"0"|"1"|"1"|"0"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"1"||"GOOD"||"310,000"|"S"|"1"|"Habiterra Architecture"|"1279 North Main Street, Jamestown, New York 14701"|"716-664-4710"|"habiterra@habiterra.com"|"David A. Walter, AIA"|"023226"|"I ACCEPT"|1/3/2011 10:17:18 AM| 846|"Gates-Chili CSD"|"26040106"|"Transportation Building"|"5004"|"07/15/10"|"910 Wegman Road"|"Rochester"|" 14624"|"ANNUAL"|"09/01/11"|"1957"|"10878"|"1"|"0"|"1"|"DISTRICT"|"OTHER"|"Transportation, maintenance"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"OTHER"|"Offices, garage and maintenance shops. "|"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"1988"|"20"|"0"||"1"|"S"|"1988"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1994"|"20"|"0"||"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"1"|"S"|"1962"|"5"|"4,253."|"Repair settlement around drainage structures at Bus Garage. Repair catch basin at southeast corner of Bus Garage Storage Bin."|"0"||||"0"||"1"|"OTHER"|"end section in I-490 drainage."|"1"|"S"|"1962"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1999"|"5"|"989,990."|"Reconstruct all pavement. Reconfigure bollards at various locations. "|"1"|"CONCRETE,ASPHALT"|"S"|"1999"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"15"|"0"||"1"|"S"|"1988"|"8"|"0"||"0"||||"0"||"1"|"S"|"U"|"1988"|"5"|"19,440."|"Replace knob hardware with lever handles in all locations in office area and Room 11. "|"0"||||"0"||"0"||||"0"||"1"|"1"|"S"|"2003"|"10"|"0"||"1"|"S"|"2007"|"20"|"0"||"1"|"1"|"S"|"1998"|"10"|"0"||"0"||||"0"||"1"|"COMMON"|"S"|"1988"|"5"|"20,250."|"Replace carpet in office areas. "|"1"|"COMMON"|"S"|"1988"|"10"|"0"||"1"|"COMMON"|"S"|"1988"|"10"|"0"||"0"|||||"0"||"SLABGRADE,WOODJOIST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1988"|"5"|"2,376."|"Repair scaling and spalling of slab at overhead door Bay 108."|"MASONRY,STEEL"|"1"|"1"||"0"|"0"|"0"|"0"|"0"||"S"|"1988"|"5"|"23,501."|"Repair brick at entire perimeter of building and other areas. Clean and paint exposed steel pipes, columns, etc. "|"0"|||||"0"||"1"|"MASONRY"|"S"|"1988"|"15"|"0"||"U"|"S"|"0"|"1"|"1988"|"5"|"30,942."|"Clean and paint steel lintels at overhead doors. Replace all exterior doors. "|"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"U"|"N"|"1988"|"5"|"81,000"|"Replace all windows. "|"METONMET,OTHER"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"1"|"0"|"0"|"1"||"U"|"1988"|"0"|"376,278."|"Replace spray foam roof system with EPDM, replace facias."|"0"|||||"0"||"1"|"GALVANIZED,COPPER"|"S"|"1988"|"20"|"0"||"1"|"IRON,GALVANIZED,COPPER"|"S"|"1988"|"20"|"0"||"1"|"NAT_GAS"|"S"|"1988"|"10"|"0"||"1"|"S"|"1988"|"15"|"0"||"0"||"1"|"FURNACE"||"S"|"2002"|"5"|"81,675."|"Replace RTU-1."|"1"|"S"|"2002"|"5"|"38,813."|"Replace furnace serving aoofice area. "|"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1988"|"5"|"77,288."|"Replace exhaust fan and make-up air unit serving Garage. "|"0"||||"0"||"1"|"S"|"2002"|"20"|"0"||"1"|"S"|"2002"|"10"|"0"||"1"|"S"|"1988"|"10"|"0"|"Not required by Code. "|"1"|"S"|"1988"|"10"|"0"|"Not required by Code. "|"0"||||"0"||"1"|"S"|"1990"|"10"|"0"|"Batteries may be reaching end of life."|"1"|"S"|"1990"|"10"|"0"||"1"|"1"|"0"||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|"0"||"0"|"1"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"1"|"SPOT,AREAWIDE"|"0"|"1"|"0"|"0"|"1"|"0"|"1"|"LIGHTING"|||"1"||"GOOD"||"1,960,515."|"U"|"1"|"LaBella Associates, P.C."|"300 State Street, Rochester, New York 14614"|"585-454-6110"|"mshort@labellapc.com"|"Michael Short"|"032717"|"I ACCEPT"|1/3/2011 10:22:50 AM| 847|"Rochester City SD"|"26160001"|"Audubon School #33"|"0033"|"08/12/2010"|"500 WEBSTER AVENUE "|"ROCHESTER "|" 14609"|"ANNUAL"|"6/01/2011"|"1966"|"154701"|"3"|"7"|"0"|"DISTRICT"|"INSTRUCT"||"1159"|"K,1,2,3,4,5,6"|"0"|"1"|"0"|"1159"|"0"|"0"|||"68"|"53510"|"GYM,KITCHEN,LIBBRARY,MULTIPURPO,MUSIC"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"25"|"0"||"1"|"UTIL"|"BELOW"|"E"|"2009"|"40"|"0"||"1"|"S"|"2000"|"10"|"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2006"|"20"|"650"|"Provide adequate signage"|"1"|"CONCRETE,ASPHALT"|"S"|"2006"|"20"|"105800"|"Rreplace sidewalks and pads. Provide adequate drainage of sidewalks and pads. Replace damage tree planted grades."|"1"|"S"|"2006"|"20"|"49000"|"Provide adequate drainage of waterpark - resurface playgrounds"|"1"|"S"|"2006"|"5"|"46000"|"N"|"repair baseball field, replace fencing"|"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1966"|"50"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"1"|"S"|"2008"|"20"|"0"||"0"||||"0"||"1"|"S"|"S"|"2008"|"20"|"0"||"1"|"S"|"1966"|"50"|"0"|"Provide vertical spindles at all stair railings"|"1"|"S"|"1966"|"10"|"0"||"1"|"1"|"E"|"2009"|"25"|"0"||"1"|"E"|"2009"|"25"|"0"||"1"|"1"|"S"|"2009"|"15"|"0"||"0"||||"0"||"1"|"INSTRUCT"|"S"|"2008"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2008"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2008"|"20"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1966"|"50"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"1966"|"50"|"0"||"1"|"MASONRY,METAL"|"S"|"1966"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"2000"|"15"|"0"|"replace exit and pair of doors and door at loading dock"|"1"|"S"|"2003"|"15"|"0"|"replace (2) sets of damaged concrete stairs and railings."|"0"|||||"0"||"1"|"ALUMINUM"|"S"|"Y"|"2008"|"20"|"0"||"CONMETMET"|"SINGLEPLY,BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"E"|"2009"|"20"|"0"|"Replace ballast in area of roof repair"|"1"|"PLASTIC"|"S"|"2009"|"20"|"0"||"1"|"COPPER"|"E"|"2008"|"50"|"0"||"1"|"IRON"|"E"|"2008"|"50"|"0"||"1"|"NAT_GAS"|"E"|"2008"|"20"|"0"||"1"|"E"|"2008"|"25"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"2003"|"25"|"0"|"replaced in 2003"|"1"|"S"|"2003"|"25"|"0"|"replaced in 2003"|"1"|"S"|"2008"|"15"|"0"|"installed BCU's in 2008"|"1"|"S"|"2008"|"15"|"0"|"installed BCU's in 2008"|"1"|"S"|"2008"|"30"|"0"|"installed with BCU's in 2008"|"1"|"S"|"2008"|"30"|"0"|"Installed with BCU's in 2008"|"1"|"S"|"2007"|"10"|"0"|"Updated in 2007/2008"|"1"|"S"|"2009"|"15"|"0"|"simplex 4100u, no classroom strobes"|"1"|"S"|"2009"|"15"|"0"|"point addressable devices installed"|"1"|"S"|"2009"|"2009"|"0"|"ansul panel in kitchen"|"1"|"E"|"2009"|"20"|"0"|"flourescent luminaires in corridor"|"1"|"S"|"2009"|"30"|"0"|"2005 generator, 2nd ATS added in 2009"|"1"|"1"|"1000"|"Provide/Additional accessible space"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"0"|"0"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"1"|"0"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"253800"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|1/3/2011 10:33:25 AM| 848|"Williamsville CSD"|"14020306"|"Transit Middle School"|"0029"|"07/06/2010"|"8730 TRANSIT ROAD "|"E AMHERST "|" 14051"|"ANNUAL"|"07/01/2011"|"1993"|"147317"|"2"|"7"|"3"|"DISTRICT"|"INSTRUCT"||"983"|"5,6,7,8"|"0"|"1"|"0"|"983"|"0"|"0"|||"59"|"56640"|"ADMIN,ART,AV,AUDITORIUM,CAFE,COMPROOM,GUIDANCE,GYM,HLTHSUITE,HOMECAREER,KITCHEN,LIBBRARY,MUSIC,REMEDIAL,RSRCEROOM,SCIENCELAB,SPECED,POOL,TEACHRSRC,TECHSHOP"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1993"|"20"|"0"||"1"|"MUN_UTILIT"|"S"|"2007"|"20"|"0"||"1"|"S"|"1993"|"20"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1993"|"18"|"0"||"1"|"S"|"1993"|"15"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"1993"|"10"|"0"||"1"|"S"|"1993"|"20"|"0"||"1"|"MUNI,OTHER"|"discharges to town ditch"|"1"|"U"|"1993"|"0"|"9750"||"0"||||"0"||"1"|"S"|"1993"|"20"|"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"1993"|"5"|"0"||"1"|"CONCRETE"|"S"|"1993"|"10"|"0"||"0"||||"0"||"1"|"E"|"1993"|"15"|"0"|"N"||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"E"|"1993"|"20"|"0"||"1"|"E"|"1993"|"20"|"0"||"1"|"S"|"1993"|"20"|"0"||"1"|"S"|"1993"|"16"|"0"||"1"|"S"|"1993"|"13"|"0"||"1"|"S"|"S"|"1993"|"19"|"0"||"1"|"S"|"1993"|"20"|"0"||"1"|"E"|"1993"|"20"|"0"||"1"|"1"|"S"|"2010"|"20+"|"0"||"1"|"S"|"2005"|"20"|"0"||"1"|"1"|"S"|"2008"|"10"|"0"||"1"|"S"|"1993"|"20"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1993"|"9"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"1993"|"17"|"0"||"1"|"COMMON"|"S"|"1993"|"18"|"0"||"1"|"COMMON"|"S"|"1993"|"13"|"0"||"SLABGRADE,CONCRMETAL,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1993"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"1"|"1"|"0"|"1"||"S"|"1993"|"20"|"0"||"1"|"METAL"|"S"|"1993"|"20"|"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1993"|"15"|"0"||"0"||||"0"||"0"|||||"0"||"1"|"ALUMINUM"|"E"|"Y"|"1993"|"20"|"0"||"METONMET,OTHER"|"SINGLEPLY,FORMMETAL,IRMA"|"0"|"0"|"1"|"0"|"0"||"0"|"0"|"0"|"1"|"1"|"0"|"1"|"1"||"S"|"1993"|"19"|"0"|"at entrances with metal roofs, concerns with non structural systems present"|"1"|"PLASTIC"|"S"|"1993"|"19"|"0"||"1"|"COPPER"|"S"|"1993"|"20"|"0"||"1"|"IRON"|"S"|"1993"|"20"|"0"||"1"|"NAT_GAS"|"S"|"2009"|"15"|"0"||"1"|"S"|"1993"|"20"|"0"||"0"||"1"|"BOILERWATE,OTHER"|"unit ventilation"|"S"|"1993"|"20"|"0"||"1"|"S"|"1993"|"20+"|"0"||"1"|"S"|"1993"|"20+"|"0"||"1"|"S"|"1997"|"20+"|"0"||"1"|"S"|"1993"|"20+"|"0"||"1"|"S"|"1993"|"20+"|"0"||"1"|"S"|"1993"|"20+"|"0"||"1"|"S"|"1993"|"8"|"0"||"1"|"S"|"1993"|"8"|"0"||"1"|"S"|"1993"|"1993"|"0"||"1"|"S"|"2005"|"20+"|"0"||"1"|"S"|"1993"|"8"|"0"||"1"|"1"|"0"|"toilet rooms were originally designed as ambulatory accessible, fully accessible rooms recommended"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"||"0"|"0"|"0"|"1"|"0"||"1"|"CLASSROOMS,OTHER"|"assembly spaces and toilet rooms"|"1"|"OTHER"|"vestibules"|"1"|"1"|"0"|"some ceiling tiles have water stains"|"0"|"1"|"0"|"0"|"0"|"1"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"|"building staff reported that fresh air filters are replaced a minimum of 3 times per year"|"0"|"1"|"1"|"1"|"0"|"1"|"0"||"0"|"0"||||"0"|"0"||"FULL"||"1"||"FAIR"||"9750"|"S"|"1"|"Kideney Architects, PC"|"200 John James Audubon Pkwy Buffalo NY 14228"|"7166369700"|"dvarecka@kideney.com"|"David Varecka"|"014101"|"I ACCEPT"|1/3/2011 10:49:49 AM| 849|"Campbell-Savona CSD"|"57060304"|"Bus Maintenance"|"5006"|"06/01/2010"|"8242 County Rte 415"|"Campbell"|" 14821"|"ANNUAL"|"08/01/2011"|"1996"|"25920"|"2"|"0"|"0"|"DISTRICT"|"OTHER"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"NONE"||"1"|"2"|"6000"|"0"|"0"|"S"|"1996"|"15"|"0"||"1"|"WELL"|"S"|"1996"|"15"|"0"||"1"|"SITESEPT"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"UTIL"|"BELOW"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"20"|"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2002"|"5"|"50000"|"Replace asphalt around concrete aprons"|"1"|"ASPHALT"|"S"|"2002"|"10"|"0"||"0"||||"0"||"0"||||"0"|||"RECONCRETE"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"35"|"0"||"1"|"S"|"1996"|"35"|"0"||"1"|"S"|"1996"|"8"|"0"||"0"||||"0"||"1"|"S"|"S"|"1996"|"5"|"1500"|"provide rated door at ofice"|"1"|"S"|"1996"|"25"|"0"||"1"|"S"|"1996"|"20"|"0"||"1"|"1"|"S"|"1996"|"15"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"0"|"S"|"1996"|"5"|"125000"|"This site need to be connected to the districy wide netwrok to take advantage of system features like VOIP, CCTV, Ect."|"0"||||"0"||"0"|||||"0"||"1"|"COMMON"|"S"|"1996"|"10"|"0"||"1"|"COMMON"|"S"|"1996"|"15"|"0"||"0"|||||"0"||"SLABGRADE,PRECAST"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"E"|"1996"|"25"|"0"||"MASONRY,STEEL"|"0"|"1"|"No"|"0"|"0"|"1"|"1"|"0"||"S"|"1996"|"5"|"10000"|"Moisture at Wash Bay causing steel columns to rust, Columns need to be scraped & painted."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"1"|"1"|"1996"|"5"|"7500"|"2 exterior doors are not opening due to heaving"|"0"||||"0"||"0"|||||"0"||"1"|"STEEL"|"S"|"NA"|"1996"|"10"|"0"||"METONMET"|"SINGLEPLY"|"0"|"0"|"0"|"0"|"0"|"No"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"|"No"|"S"|"1996"|"10"|"0"||"0"|||||"0"||"1"|"COPPER"|"S"|"1996"|"15"|"0"||"1"|"IRON"|"S"|"1996"|"15"|"0"||"1"|"NAT_GAS"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"1"|"CV"|"1"|"BOILERWATE"||"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"15"|"0"||"0"||||"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"5"|"8000"|"wash bay duct work is corroded and needs to be replaced."|"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"1"|"S"|"1996"|"10"|"0"||"0"||||"0"||"1"|"S"|"1996"|"5"|"25000"|"additional emergency lighting is needed."|"0"||||"0"||"1"|"1"|||"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"NA"|"GOOD"||"0"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"FAIR"|"1"|"FAIR"||"0"|"1"|"1"|"1"|"1"|"1"|"0"||"0"|"1"|"0"|"0"|"0"|"0"|"0"|||"0"|"1"||"GOOD"||"648300"|"S"|"0"|"HUNT- Engineers, Architects and Land Surveyors"|"100 Hunt Center, Horseheads, NY 14845"|"607-358-1000"|"woodcockc@hunt-eas.com"|"Charles Woodcock"|"022419"|"I ACCEPT"|1/3/2011 10:54:52 AM| 850|"Rochester City SD"|"26160001"|"Dr. Lewis Cerulli School #34"|"0034"|"08/18/2010"|"530 LEXINGTON AVENUE "|"ROCHESTER "|" 14613"|"ANNUAL"|"06/01/2011"|"1927"|"64281"|"2"|"3"|"0"|"DISTRICT"|"INSTRUCT"||"253"|"Pre-K,K,1,2,3,4,5,6"|"0"|"0"|"1"|"483"|"40"|"0"|||"29"|"20963"|"ART,AUDITORIUM,GYM,LIBBRARY,MULTIPURPO,MUSIC,PREK"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"25"|"0"||"1"|"MUN_UTILIT"|"S"|"2004"|"25"|"0"||"1"|"S"|"2004"|"25"|"0"||"1"|"UTIL"|"BELOW"|"S"|"2004"|"25"|"0"|"repair electrical box on light pole"|"0"||||"0"||"1"|"S"|"2004"|"5"|"19500"|"repair collapsed catch basin and provide drainage improvements"|"0"||||"0"||"0"||||"0"||"0"|||||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2004"|"10"|"0"||"1"|"CONCRETE"|"S"|"2004"|"5"|"0"|"replace cracked sidewalk at various locations"|"1"|"S"|"2004"|"10"|"0"|"top dress and seed area aound playground"|"1"|"S"|"2004"|"50"|"0"|"N"||"RECONCRETE,MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1962"|"45"|"0"|"repair cracks and spalling at beam - repair cracks and spalling at water table"|"1"|"S"|"1962"|"45"|"0"||"1"|"S"|"1962"|"45"|"0"||"1"|"S"|"1988"|"10"|"0"||"1"|"S"|"2001"|"20"|"0"||"1"|"S"|"S"|"1962"|"10"|"0"|"Provide safety glass, fire rated doors, install closers"|"1"|"S"|"1962"|"45"|"0"||"1"|"S"|"1962"|"45"|"0"||"1"|"1"|"S"|"2003"|"5"|"0"|"replace 5 existing panels and feeders"|"1"|"S"|"2003"|"15"|"0"||"1"|"1"|"S"|"2009"|"10"|"0"|"PA and clock installed in 2001, switches in 2009"|"0"||||"0"||"1"|"INSTRUCT"|"S"|"2007"|"10"|"0"||"1"|"INSTRUCT,COMMON"|"S"|"2007"|"20"|"0"||"1"|"COMMON"|"S"|"2007"|"20"|"0"||"1"|"INSTRUCT"|"S"|"2007"|"15"|"0"||"SLABGRADE,CONCRMETAL"||"0"|"0"|"0"|"0"|"0"||"1"|"0"|"0"|"S"|"1962"|"45"|"0"||"MASONRY"|"0"|"0"||"0"|"0"|"0"|"0"|"0"||"S"|"2010"|"45"|"0"|"Masonry repointing done, added control joints in 2010 CIP"|"1"|"MASONRY"|"S"|"1927"|"45"|"0"|"repointing required"|"1"|"MASONRY"|"S"|"1991"|"20"|"0"|"further parapet repointing, repair and replacement required"|"S"|"S"|"0"|"1"|"2004"|"10"|"0"|"pointing required"|"1"|"S"|"2004"|"15"|"0"||"0"|||||"0"||"1"|"WOOD,WOODCLAD"|"S"|"Y"|"1997"|"15"|"0"||"METONMET,CONMETMET"|"BUILTUP"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"0"||"S"|"1982"|"5"|"0"||"1"|"GLASS"|"S"|"1982"|"5"|"0"|"skylight glass has a crack"|"1"|"COPPER"|"S"|"2004"|"30"|"0"||"1"|"IRON,COPPER"|"S"|"2004"|"30"|"0"||"1"|"NAT_GAS"|"S"|"2004"|"15"|"0"||"1"|"S"|"2009"|"25"|"0"||"0"||"1"|"BOILERWATE"||"S"|"1997"|"30"|"0"||"1"|"S"|"1997"|"30"|"0"|"gas piping replaced with boiler in 1997"|"1"|"S"|"2003"|"15"|"0"|"split systems "|"1"|"S"|"1997"|"20"|"8000"|"replace EF-04,05,06, and 07"|"1"|"S"|"1997"|"30"|"0"|"HWS/R piping replaced with UV's"|"1"|"S"|"1998"|"15"|"0"|"ductwork replaced/modifired with UV and EF replacements."|"1"|"S"|"1998"|"15"|"0"|"upgraded during 1998 addition"|"1"|"S"|"2003"|"10"|"0"|"replace with point addressable, add classroom strobes"|"1"|"S"|"2003"|"10"|"0"|"replace with addressable devices"|"0"||||"0"||"1"|"S"|"2003"|"15"|"0"||"1"|"S"|"2004"|"30"|"0"|"Detroit diesel 125 kw installed 2004 with dual ATS"|"0"|"1"|"0"|"stage requires a lift for access, provide an additional accessible parking space"|"GOOD"||"GOOD"||"1"|"1"|"GOOD"||"DAYLIGHT,FL_ FULL"|"FAIR"||"1"|"0"|"0"|"0"|"0"||"0"|||"0"|||"1"|"1"|||"0"|"0"|"0"|"0"|"0"|"0"|"GOOD"|"0"|"0"|"0"|"0"|"1"|"0"|"1"|"GOOD"|"1"|"GOOD"||"1"|"0"|"0"|"1"|"1"|"1"|"0"||"0"|"0"||||"0"|"0"||||"0"|"0"|"GOOD"||"506601"|"S"|"1"|"Clark Patterson Lee Design Professionals"|"205 St. Paul Street, Suite 500, Rochester, NY, 14604"|"800-274-9000"|"BTrott@ClarkPatterson.com"|"Brian Trott"|"025971"|"I ACCEPT"|1/3/2011 10:57:53 AM| 851|"Cleveland Hill UFSD"|"14070302"|"Administration Building"|"1008"|"04/01/2010"|"3660 Harlem Road"|"Cheektowaga"|" 14225"|"ANNUAL"|"12/01/2010"|"1960"|"4320"|"1"|"0"|"0"|"DISTRICT"|"DIST_ADMIN"||"0"|"UNGRD"|"0"|"0"|"0"|"0"|"0"|"0"|||"0"|"0"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1960"|"10"|"0"|"No reduced pressure backflow prevention device (RPZ) installed."|"1"|"MUN_UTILIT"|"S"|"1960"|"10"|"0"||"1"|"S"|"2001"|"7"|"0"|"Exposed gas piping, not painted. No identification markers installed. Supports observed to be rotting and locations insufficient."|"1"|"UTIL"|"ABOVE"|"U"|"1960"|"3"|"1,600.00"|"Exposed wiring in in pole is rusting. Wiring should be placed in flex liquid tight conduit. Lighting fixture on exterior of building damaged."|"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"|||"1"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"0"||||"0"||"1"|"ASPHALT"|"S"|"2009"|"10"|"0"|"Resurfaced in 2009, minor surface defects from plow at driveway entry."|"1"|"CONCRETE"|"NF"|"1960"|"1"|"2928.00"|"Stretch of sidewalk to residential properties in extreme disrepair."|"0"||||"0"||"0"||||"0"|||"MASONCON"|"0"|"0"|"0"|"0"|"0"|"0"|"S"|"1960"|"15"|"0"|"Most of foundation was covered by paving."|"0"||||"0"||"1"|"S"|"1990"|"20"|"0"||"1"|"S"|"1990"|"10"|"0"|"Multiple tiles have water stains and may need to be replaced."|"0"||||"0"||"1"|"S"|"S"|"1960"|"7"|"0"||"0"||||"0"||"0"||||"0"||"1"|"1"|"U"|"2005"|"3"|"$6,400.00"|"Existing panel board modified with 100 amp main and rated for only 50 amps, recommend replacing panel."|"1"|"U"|"2000"|"3"|"$65,650.00"|"Sagging lenses. T12 lamping. Recommend replacing all lighting fixtures with new lighting fixtures with T8 or T5 technology."|"1"|"1"|"S"|"1960"|"7"|"0"||"0"||||"0"||"1"|"COMMON"|"U"|"2000"|"3"|"$18,993.25"|"Carpet worn and dirty."|"1"|"COMMON"|"S"|"2000"|"7"|"0"|"Appears that asbestos tile is under carpeted area"|"0"|||||"0"||"0"|||||"0"||"SLABGRADE"||"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"S"|"1960"|"20"|"0"||"MASONRY"|"0"|"0"||"1"|"0"|"1"|"0"|"0"||"S"|"1960"|"15"|"0"|"North side of building has a hole where equipment was removed and not patched. Sills near grade have disintegrated an are in need of repair. Some efforescence at the front door."|"0"|||||"0"||"0"|||||"0"||"S"|"S"|"0"|"1"|"1990"|"5"|"0"|"Back door is rusted and paint is peeling."|"0"|"S"|"1960"|"10"|"0"|"Recommended that side door ramp be replaced with a single elevated pad. This exit is not required to be a ramp."|"0"|||||"0"||"1"|"VINYL"|"S"|"NA"|"2000"|"10"|"0"||"METONMET"|"OTHER"|"0"|"0"|"0"|"0"|"0"||"0"|"0"|"0"|"0"|"0"|"0"|"0"|"1"||"U"|"2005"|"3"|"0"|"$60,700.00"|"0"|||||"0"||"1"|"COPPER"|"S"|"1960"|"10"|"0"|"Sections of piping are not insulated. No piping identification markers installed."|"1"|"IRON,PVC"|"U"|"2005"|"3"|"$4,000.00"|"Vents through roof do not extend 18 inches above roof line per code."|"1"|"ELECTRIC"|"E"|"2005"|"7"|"0"||"1"|"S"|"1960"|"7"|"0"||"1"|"CV"|"0"||||||"0"||"1"|"S"|"1960"|"7"|"0"||"0"||||"0"||"1"|"S"|"2002"|"7"|"0"|"2-units do not have roof curbing."|"0"||||"0"||"1"|"U"|"1960"|"3"|"$10,000.00"|"Ductwork installed with orginal units nearing end of useful life."|"1"|"S"|"1960"|"5"|"0"||"1"|"S"|"2000"|"7"|"0"|"No manual pull stations"|"1"|"S"|"2000"|"7"|"0"||"0"||||"0"||"1"|"U"|"2000"|"3"|"$800.00"|"Emergency lights do not operate. Recommend replacing all."|"0"||||"0"||"1"|"1"|"0"|"There is an accessible interior and exterior route."|"GOOD"||"GOOD"||"0"|"0"|"GOOD"||"DAYLIGHT,FL_NOT_Ful"|"GOOD"|"Lighting levels are adequate, lighting should be changed out from T12 to T18 or T5 technology."|"0"|"0"|"0"|"0"|"0"||"1"|"OTHER"|"Common Areas"|"0"|||"1"|"1"|"5000"|"Moisture evident in most rooms."|"0"|"0"|"0"|"0"|"0"|"1"|"FAIR"|"0"|"0"|"0"|"0"|"1"|"0"|"0"|"FAIR"|"1"|"FAIR"|"Two ventilation units aer older from 1970's or 1980's."|"0"|"1"|"1"|"1"|"1"|"0"|"1"|"SPOT"|"0"|"1"|"0"|"0"|"1"|"0"|"0"|||"1"|"1"||"FAIR"||"171,071.25"|"U"|"0"|"Young + Wright Architectural"|"740 Seneca Street"|"716-842-1800"|"shawnwright@youngarch.com"|"Shawn P. Wright"|"029492"|"I ACCEPT"|1/3/2011 11:00:10 AM| 852|"BOCES Genesee Valley (Gen-Liv-Steu-)"|"24900000"|"LEASE @ GENESEE CO BLDG #2 "|"8044"|"09/08/2010"|"3837 West Main Road "|"Batavia"|"14020"|"ANNUAL"|"08/01/2011"|"1966"|"3328"|"1"|"0"|"0"|"LSD_DIST"|"INSTRUCT"||"50"|"OTHER"|"0"|"1"|"0"|"50"|"0"|"0"|||"3"|"3000"|"ADMIN"||"0"||||||||"0"||"1"|"MUN_UTILIT"|"S"|"1966"|"15"|"0"||"1"|"MUN_UTILIT"|"S"|"196